FIR2023-0116+Fire_Alarm_Equipment_Specification_Sheets+12.4.2023_11.53.48_AM+3931857The Trike Stop - Fire Alarm Job Number: 24495 24495-The Trike Stop - FA RECEIVED Dec 04 2023 "Tv of EDMorvo. DEV—PMENT SERVICES DEPARTMENT FIR2023-0116 Table of Contents Spec # Manufacturer Section Doc Name Fire Alarm System Honeywell 1100-0452 Honeywell 1100-0456 Honeywell 1100-0460 Honeywell AMM-21F Honeywell ASD-PL3-IV Honeywell B300-6-IV Honeywell E3BB-FLUSH-LCD Honeywell HPFF12 Honeywell INI-VGX Honeywell LCD-SLP Honeywell MS-7AF Honeywell PM-9 Honeywell RPT-E3-UTP Honeywell SPSCWL Yuasa NP1812B Doc # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Fire Alarm System Honeywell Garr ewell Mass Notification, E3 Series, In -Building E3 Series' LOC Local Operating Console General The Gamewell-FCI, E3 Series°, Local Operating Console (LOC) is a paging component that houses the modules that support the remote audio paging devices used for emergency notification. It can be remotely distributed in real-time via pre-recorded messages, live voice paging, or text messages. It is used in the following E3 Series Systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System to comply with the DOD, United Facilities Criteria (UFC) guidelines • E3 Series Broadband Voice Evacuation Systems The LOC's robust distributed messaging capabilities allow users to program the system to broadcast messages that automatically change as the situation changes. This versatile feature makes it possible for the system to simultaneously distribute different emergency communications to zones, floors, multiple buildings, large outdoor campuses or facility areas. The Local Operating Console uses a state-of-the-art Digital Signal Processor (DSP) that produces reliable, high fidelity audio messaging and it allows live voice instructions. The Network Touchscreen Graphic Annunciator(NGA) provides the LOC with the capability to display text messaging over the network to all Local Operating Consoles within a protected area. The Addressable Switch Module (ASM-16) includes 16 programmable switches for message, control, and zone paging. The E3 Series LOC communicates overthe network, allowing full communication and control over a single pair of wires or fiber-optic cable. This E3 Series distributed architecture, including Style 7 wiring configuration, provides complete supervision and survivability if a fault condition occurs orthe system is compromised. All LOCs on the network are supervised. The Local Operating Console comprises the following components: • AA Cabinet with mounting patterns for the INI-VG Series • 3-slot inner door for mounting the following: - One INCC-MIC paging microphone - One or two ASM-16s - One ASM-16 and one NGA Note: Gamewell-FCI recommends you install the speakers at 4 ft. (1.2 m) or more from the microphone. FEATURES & BENEFITS • Listed under UL° Standard UL2572 for Mass Notification • IBC Seismic Certified • Offers instantaneous audio or text messaging • Includes an optional thumb quarter turn latch and trim ring available • Includes 16 message capacitywith up to a 3 minute duration per each LOC • Supports up to two ASM-16 modules for a total of 32 switches used for each LOC • Allows messages to be easily field -configured via a laptop computer • Built of a 16-gauge steel backbox with a full Lexan°window and keylock on the door E3, LOC • Provides all communication signals and control -by event sequences connected overtwisted, unshielded pair of wires or fiber-optic cable • Uses E3 Series distributed architecture, including Style 7 wiring configuration • Transmits at a network data transfer rate of 625K baud E3 Series' LOC Technical Specifications SYSTEMS E3-LOC: Local Operating Console Dimensions: 191/4"W x 10"H x 41/4" D (48.9W x 25.4 x 10.8 D cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 -120°F and at a relative humidity 93%± 2% RH (non -condensing) at 32°C ± 2°C (90°F± 309. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Ordering Information E3BB-BAA: AA Cabinet 1100-0452: INCC-MIC, Paging Microphone 1tba34bb:e'AiST�'ri-ib' A dressaMe bwitcn module INI-VG Series (Third Generation -Voice Gateway Models): INI-VGC: (Command Center Voice Gatewaywith unshielded twisted -pair wire networking, optionalfiber- optic module connection FML-E3: Fiber-optic module, multi -mode fiber connector, single channel FSL-E3: Fiber-optic module, single -mode fiber connector, single channel INI-VG Series (Legacy Models): 1100-1321: INI-VGC-FO (Command Center Voice Gateway -fiber-optic module) 1100-1322: INI-VGC-UTP (Command Center Voice Gateway -unshielded twisted -pair only) Optional Components: 1100-0505: NGA, Network Graphic Annunciator Thumb lock: Thumb quarter turn latch E3-TRIMKIT-A: Trim Ring For more information Learn more about Gamewell-FCI's E3 Series* LOC and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The E3 Series, Local Operating Console (LOC) is designed to comply with the following standards: UL Standards: 864 9th Edition, 2572 for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 2572 for Mass Notification FM Approved:3025415 MEA Approved -Fire Dept. of New York: COA# 231-06-E CSFM: 7165-1703:0125, 7170-1703:0126 City of Chicago: Class 1, Class 2 and High Rise City of Denver Approved VMC Reference of Certification: VMA-45894-02C ISO 9001 Certification 9021-604861 E 1 10/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gameweL[- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI° are registered trademarks of Honeywell International Inc. Lexan° is a registered trademark of GE Plastics, a subsidiary of General Electric Corp. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, AM-50 Series amplifiers are a 50 watt, digital, switching power amplifier. The following lists the 2 types of AM-50 Series amplifiers that may be ordered. • The AM-50-25 amplifier produces 25 VRMs audio output. • The AM-50-70 amplifier produces 70.7VRMS audio output. The amplifiers are components of the following E3 Series® Systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System WARNING: AM-50 Series Amplifiers Node Restriction: The INI-VGX can support up to 4 AM-50 Series amplifiers with the same output voltage. However, you cannot wire an AM-50-25 amplifier and an AM-50-70 amplifier to the same INI-VGX Voice Gateway Node. Each AM-50 Series amplifier provides 2 speaker circuits that can be wired Style Y (Class "B") or Style Z (Class "A"). The terminal connections can accommodate up to 12 AWG, twisted -pair, shielded wire. Both speaker circuits pro- duce a combined total of 50 watts of power. The 50 watts of power can be divided between the 2 integral Class A/B speaker circuits. The 2 speaker circuits may be individually activated and supervised by an INI-VGX Transponder Voice Gateway. The AM-50 Series amplifier can be programmed to broad- cast 16 messages generated from its local INI-VGX Voice Gateway. In addition, the AM-50 Series amplifiers produce superior clarity for intelligible LIVE voice paging. When the selected System Sensor, SpectrAlert® Advance Series speakers are used with the Manufacturer's 520 Hz audiophile, the E3 Series® System is compliant with UL Standard 464 Low Frequency requirements. For additional information, refer to the SpectrAlert Advance Series Data Sheet, P/N:9021-60346. Installation As many as four AM-50 Series amplifiers can be installed in the following cabinets when supervised and controlled by an INI-VGX Voice Gateway. • Cabinet B, INX CAB-B • Cabinet C, INX-CAB-C • Cabinet D. INX-CAB-D E3jeries0 and SpectrAlert® are registered trademarks of Honeywell International Inc. UL is a registered trademark of Underwriters Laboratories, Inc. AM-50 Series AM-50 Series Amplifiers AM-50-25 AM-50-70 Featu res • Listed under UL® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Complies with UL Standard 464 for 520 Hz Low Frequency. • Provides digital, switching amplifier technology. • Produces 50 watts of digital power. • Includes 2 speaker circuits, wired Style Y (Class B) or Style Z (Class A). • Up to 4 AM-50 Series amplifiers with the same out- put voltage can be controlled by the INI-VGX voice gateway. SIGNALING U� Fm M� Approved LISTED APPROVE,V D FDNY: City of Chicago Approved City Of Class 1 DENVER S1869 3017416 COA #6077 7165-1703:0125 Class 2 Approved High Rise IS® GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2015 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0556 Rev. K1 page 1 of 2 Description (Continued) The AM-50 Series amplifiers can be installed using the AM-50 Extender Plate whenever the E3 Series control panel is used in conjunction with the Autonomous Control Unit of the E3 Series Combined Fire and Mass Notification System. • Cabinet C, E3 INCC-CAB-C For additional information, refer to the E3 Series Combined Fire and Mass Notification Data Sheet, P/N:9021-60758 Specifications AM-50-25 Amplifier Operating Voltage: Operating Current: Alarm Current: Audio Output: AM-50-70 Amplifier Operating Voltage: Operating Current: Alarm Current: Audio Output: AM-50 Series Amplifiers Relative Humidity: Operating Temperature: Dimensions: 27.3 to 20.4 VDC 0.086 amp normal standby 2.206 amp max. alarm @ 50 Watt 50 watts max. @ 25 VRMs 27.3 to 20.4 VDC 0.049 amp normal standby 2.30 amp max. alarm @ 50 watt 50 watts max. @ 70.7 VRMs 0 to 93% max., (non -con- densing) at 90° F (32° C) 32' to 120' F (0' to 49' C) 7 1 /2" W x 3 1 /2" H x 1 1 /4" D (19 W x 9 H x 3 D cm) Ordering Information Part Number Description 1100-0456 AM-50-25, INX 25VRMs audio output, 50 watt amplifier AM-50-70 INX 70.7VRMS audio output, 50 watt amplifier GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0556 Rev. K1 page 2 of 2 www.gamewell-fci.com E 2 SERIFS" *APINETe Cabinets used for the E3 Series System The E3 Series' Cabinets offer a variety of cabinet options to house either the E3 Series or S3 Series fire alarm control panel systems. GENERAL The E3 Series' Expandable Emergency Evacuation System by Gamewell-FCI offers several cabinet size options. The E3 Series System is a modular design that allows a wide range of configurations to form an integrated, distributed fire alarm system. These cabinet options allow for sturdy and modern installations. The E3 Series cabinet assembly is a compact, wall -mounted enclosure. A typical cabinet includes a backbox and an outer locking door. In addition, there are several inner door options and mounting plates to accommodate a variety of E3 Series sub -assemblies. Each cabinet backbox includes mounting patterns for plates to allow the installer to arrange and secure the sub -assemblies to the backbox. The backbox knockouts are also positioned at numerous points to allow a conduit access into the enclosure. There are four Annunciator cabinet sizes which provide the maximum flexibilitythat can meet any application: • Cabinet AA offers 2 slot or 3 slot options to accommodate any of the following configurations: - Inner door, 2 slots allows space for one LCD-E3 or LCD-SLP and one ASM-16 - Inner door, 3 slots allows space for any combination of three modules: ASM- 16, NGA or an ANU-48 • Cabinet Al houses one NGA or one ASM-16/ANU-48. • CabinetA2 accommodates a single LCD-E3. • E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. The E3BB-R-B-Slim or B-Slim contains the 600 Series cabinet. Cabinet B includes a mounting plate that contains a space for the following modules: • ILI-MB-E3/ILI95-MB-E3 • PM-9/PM-9G sub -assemblies • Batteries set inside the backbox Additional sub -assembly options mounted on the backbox include the DACT-E3 and RPT- E3. The 2 slot inner door houses the following options: • one LCD-E3 module and • either one ASM-16/ANU-48 or one NGA module FEATURES AND BENEFITS • IBC Seismic Certified • 16-gauge steel backbox • Offers cabinets available in either black or red • Provides removable cabinet outer and inner doors • Includes an inner door bonding strap used to provide electrical continuity for grounding • Designed with Lexan° windows that appear on the outer doors of most cabinets, except the following cabinets that contain louvered doors: E3 Series' Cabinets • Designed with a 90' opening door with zero clearance • Contains a keylock with a quarter turn latch - Cabinet"C" INX • Optional Trim Ring accessories - Cabinet"D" INX available - Cabinet INX CAB-B • Furnished backbox and door ground studs provide positive grounding. 1800 opening door with full clearance Honeywell a o GENERAL Both the C and D size Command Center cabinets house a variety of E3 Series Broadband sub -assemblies that can be used in multiple configurations that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and D size Command Center cabinets that may contain any of the following: • fire fighter's phone handset • microphone • optional modules to meet the facility operation requirements. Refer to the Inner Door and Backbox Mounting Capacities in the Ordering Information Section. ORDERING INFORMATION Inner Door Mounting Capacity: Cabinet "AA" Size: Dimensions: 19 1/4"W x 10"H x 41/2"D, (49W x 25H x 11.4D cm) E31313-13AA: Enclosure, Black, "AA" (LOC) Size E31313-RAA: Enclosure, Red, "AA" (LOC) Size E31D2-TA: Inner Door, 2 Slots, (INCC-TEL & ASM-16) E31D2-A: Inner Door, 2 Slots, (LCD-E3 or LCD-SLP &ASM-16) E31D3-A: Inner Door, 3 Slots,(NGA, ASM-16 and MIC) Cabinet "AA1" Size: Dimensions: 8 3/4"W x 10"H x 41/2"D, (22W x 25H x 11.4D cm) E31313-13AA1: Remote Enclosure, Black, w/Inner Door, 1 slot, (NGA) E31313-RAA1: Remote Enclosure, Red, w/Inner Door, 1 Slot, (NGA) Cabinet "A2" Size: Dimensions: 13 1/4"W x 10"H x 41/2"D, NOW x 25H x 11.4D cm) E31313-13A2: Remote Enclosure, Black, w/Inner Door, 1 Slot, (LCD-E3 or LCD-SLP) E31313-RA2: Remote Enclosure, Red, w/Inner Door, 1 Slot, (LCD-E3 or LCD-SLP) Flush Cabinet A2 Annunciators: Dimensions: 13 1/4"W x 10"H x 41/2"D, NOW x 25H x 11.4D cm) E31313-FLUSH-1-CD: CAB A2 Remote Flush LCD ANN with Key switch operation E3136-NGA-FLUSH: CAB A2 Remote Flush NGA ANN with Password protected Cabinet "B-Slim" Size: (Retrofit Kits): Dimensions: 14"W x 20"H x 41/2"D, (35.5W x 50.8H x 11D cm) E3BB-RBSLIM: Assembly, Enclosure, B-SLI M, Red with Backplate and _CD-E3 Keyswitch plate. IF600-RETROFIT: Door and Cab mounting plates, disable key switch and door lock (PK-625) for E3 Series upgrade. ORDERING INFORMATION (CONTINUED) Cabinet "B" Size: Dimensions:19 3/8"W x 19 3/8"H x 41/2"D, (49W x 49H x 11D cm) E31313-BB: Assembly, Backbox Enclosure, Black,"B" Size E3BB-RB: Assembly, Backbox Enclosure, Red, "B" Size E311)2-13: Inner Door, 2 Slots, "B" Size 1100-0460: INX-Transponder 19" (cm) Backbox with Door, Black Dimensions:19 3/8"Wx19 3/8"Hx41/2"D, (49Wx49Hx11.43 D cm) Cabinet "C" Size: Dimensions:19 3/8"W x 30"H x 41/2"D, (49W x 76H x 11D cm) E31313-13C/INCC: Enclosure, Command Ctr, Black, "C" Size E3BB-RC/INCC: Enclosure, Command Ctr, Red, "C" Size E302-C: Assembly, Inner Door, Command Center, 2- Bay "C" Size E31D3-C: Assembly, Inner Door, Command Center, 3-Bay "C" Size E366-13C/INX: Assembly, Transponder, Black, "C" Size E31313-RC/INX: Assembly, Transponder, Red, "C" Size E3-INCC-CPLATE: Command Center module mounting plate, "C" Size E3-INX-CPLATE: Transponder mounting plate, "C" Size Inner Door Mounting Capacity: E3-ILI-CPLATE: Intelligent loop module mounting plate "C" Size Cabinet "D" Size: Dimensions:19 3/8"W x 41"H x 41/2"D, (49W x 104H x 11D cm) E366-13D/INCC: Enclosure, Command Center, Black, "D" Size E3BB-RD/INCC: Enclosure, Command Center, Red, "D" Size E31D2-D: Assembly, Inner Door, 2-Bay, "D" Size E31D3-D: Assembly, Inner Door, 3-Bay, "D" Size E31313-13D/INX: Enclosure, Transponder, Black "D" Size E31313-RD/INX: Enclosure, Transponder, Red, "D" Size E3-INCC-D-PLATE: CommandCentermodulemountingplate D-Size E3-INX-D-PLATE: Transponder module mounting plate, "D" Size Optional Extender Plates: AM-50 Plate: AM-50 Extender Plate FPT-GATE-3-EXT: FPT-GATE-3 Extender Plate Optional Accessories: 1100-0450: Command Center, blank plate, single size E3-BP: Inner door panel, blank, double size 90375: PM-9/PM-9G Adapter Plate Kit, Hardware E3-TRIMKIT-A: Trim kit for 'WWAA" size enclosure, black E3-TRIMKIT-Al: Trim kit for "AAl" size enclosure, black E3-TRIMKIT-A2: Trim kit for "A2" size enclosure, black E3-TRIMKIT-B:Trim kit for "B" size enclosure, black E3-TRIMKIT-C: Trim kit for "C" size enclosure, black E3-TRIMKIT-D: Trim kit for "D" size enclosure, black Page 2 of 5 — 9020-0649:X ORDERING INFORMATION (CONTINUED) Inner Door Mounting Capacity Bulk Amplification: Part Number Number AA-100:100 W Audio Amplifier, @70.7 VRMS with 120 VAC of Components Cabinet AA AA-120:120 W Audio Amplifier, @25 VRMS with 120 VAC E31D2-A- (Cabinet AA, Inner Door, 2 Slots) ACT-1: Audio coupling transformer, for audio systems LCD-E3 Display and ONE w/multiple supplies. ASM-16/ANU-48 ONE FCI-CHG-120: Battery Charger, 25-120A/H Gel cell E31D2-TA-(Assembly, Door, Inner,TEL-E3) FCI-LBB: Battery box, accommodates batteries up to 55 A/H, E31D3-A -(Cabinet A, Inner Door, 3 Slots) (Black). NGA orASM-16 ONE ASM-16s/ANU-48 TWO Cabinet C: Cabinet AAl FCI-DR-C4B: Large Battery Backbox, Blank door, lock & keys, E31D-A1 -(Cabinet AAl, Inner Door (includes Box) for backbox accepting 3 chassis, (Black). NGA orASM-16 ONE FCI-DR-C4BR: Blank door, lock & keys, for backbox Cabinet A2 accepting 3 chassis, (Red). E31D-A2 - (Cabinet A2, Inner Door, (includes Box) SBB-C4: Backbox, 3 chassis, (Black) LCD-E3 Cabinet B ONE Cabinet D: E31D2-B - (Cabinet B, Inner Door, (includes Box) FCI-DR-D4B: Blank door, lock & keys, for backbox accepting LCD-E3 Display and one ASM-16/ANU-48 ONE 4 chassis, (Black) NGA and one ASM-16/ANU-48 ONE FCI-DR-D4BR: Blank door, lock & keys, for backbox accepting B-Slim Cabinet 4 chassis, (Red) LCD-E3 Display & one RPT-E3 or one DACT-E3 ONE SBB-D4: Backbox, 4 chassis, (Black) ILI-MB-E3 or one ILI95-MB-E3 ONE PM-9 or one PM-9G ONE 90516: 7100-Slim 7 A/H Seismic Battery Bracket Kit Cabinet C Seismic Battery Bracket Kits: E31D2-C- (Cabinet C, Inner Door, 2 Slots) E3 B-Slim 7 A/H Seismic Battery Bracket Kit LCD-E3 Display and ONE 90517: 7100-Slim 12 A/H Seismic Battery Bracket Kit AnycombinationofASM-16/ANU-48, NGAor FIVE E3 B-Slim 12 A/H Seismic Battery Bracket Kit Microphone Assemblies 90518: E3 CAB-B 7 A/H Seismic Battery Bracket Kit Telephone Assembly E31D3-C- (Cabinet C, Inner Door, 3 Slots) ONE E3 CAB-C 7 A/H Seismic Battery Bracket Kit Any Combination of ASM-16/ANU-48, NGA, or SEVEN E3 CAB-D 7 A/H Seismic Battery Bracket Kit Microphone Assemblies NetSOLO NS-INX 7 A/H Seismic Battery Bracket Kit Telephone Assembly ONE NetSOLO 7100 7 A/H Seismic Battery Bracket Kit Cabinet D 90519: E3 CAB-C (INX only)12 A/H Seismic Battery Bracket Kit E31D2-D - (Cabinet D, Inner Door, 2 Slots) LCD-E3 Display ONE E3 CAB-D (INX only)12 A/H Seismic Battery Bracket Kit Any Combination of ASM-16/ANU-48,orNGAor ELEVEN NetSOLO NS-INX 12 A/H Seismic Battery Bracket Kit Microphone and 90520: E3 CAB-B 18 A/H Seismic Battery Bracket Kit Telephone Assembly ONE E3 CAB-C 18 A/H Seismic Battery Bracket Kit E31D3-D -(Cabinet D, Inner Door, 3 Slots) E3 CAB-D 18 A/H Seismic Battery Bracket Kit Any Combination of ASM-16/ANU-48, NGA or THIRTEEN Microphone Assemblies Retrofit Kits: Telephone Assembly ONE For information on the Gamewell and 7200 Retrofit Kits, refer to the Backbox Mounting Capacity following Data Sheets. E3BB-BAA-(Enclosure,"AA'(LOC)Size, Black) 9021-60678: Gamewell Retrofit Kits Data Sheet INI-VG Series Voice Gateway ONE 9021-60733: 7200 Retrofit Kits Data Sheet E3BB-BAA1- (AA1 Size Box/Door, Black) RPT-E3 Network Repeater ONE E3BB-BB B-Size Box/Door, Black PM-9/PM-9G Power Supply ONE ILI-MB-E3/ILI95-MB-E3 and ONE Additional ILI-MB-E3/ILI95-MB-E3 ONE Loop Interface or ANX or ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE INX CAB-B Mounting Plate PM-9 or PM-9G ONE INI-VGX ONE AM-50 Series amplifiers FOUR 9020-0649:X • 05/01/2020 Page 3 of 5 Backbox Mounting Capacity (Continued) Part Number Number of Components E3-INCC-C Plate PM-9/PM-9G Power Supply ONE INI-VG Series Voice Gateway ONE I1-I-MB-E3/I1-I95-MB-E3 Loop Interface and ONE Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE Optional AM-50 or FPT-GATE-3 Extender Plate ONE E3-ILI-C Plate PM-9/PM-9G Power Supply ONE ILI-MB-E3 or ILI95-MB-E3 ONE Additional ILI-MB-E3/ILI95-MB-E3 or ILI-S-E3/I1-I95-S-E3 or TWO ANX DACT-E3 0 N E RPT-E3 ONE Optional FPT-GATE-3 Extender Plate ONE E3-INX-C Plate PM-9/PM-9G PowerSupplywith one PM-9/PM-9GAdapter ONE Plate INI-VGX Voice Gateway 0 N E I1-I-MB-E3 Loop Interface and ONE Additional ILI-MB-E3/LI95-MB-E3/ANX ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE AM-50 Series Amplifier FOUR Optional FPT-GATE-3 Extender Plate ONE Backbox Mounting Capacity (Continued) Part Number Number of Components E3-INCC-D Plate PM-9/PM-9G Power Supply ONE ILI-MB-E3 or ILI95-MB-E3 ONE Additional ILI-E3 or ILI95-E3 Series or ANX FOUR DACT-E3 Digital Communicator ONE RPT-E3 Network Repeater ONE INI-VG Series ONE Optional AM-50 or FPT-GATE-3 Extender Plate ONE E3-INX-D Plate PM-9/PM-9G Power Supply ONE ILI-MB-E3 or ILI95-MB-E3 ONE DACT-E3 Digital Communicator ONE RPT-E3 Network Repeater ONE INI-VG Series ONE AM-50 Series Amplifier FOUR Optional FPT-GATE-3 Plate ONE E3BB-BD - (D Size Box/Command Center (Voice), Black) PM-9/PM-9G Power Supply ONE INI-VG Series Voice Gateway ONE ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface FOUR Additional ILI-MB-E3/ILI95-MB-E3/ANX Loopinterfaceor ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE Optional FPT-GATE-3 Plate ONE E3BB-BD - (D Size Box/Command Center, Black) PM-9/PM-9G Power Supply ONE ILI-MB-E3/I1-I95-MB-E3/ANX Loop Interface & Additional SEVEN ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE Optional Extender Plates AM-50 Extender Plate AM-50-25 or AM-50-70 ONE FPT-GATE-3 Extender Plate FocalPoint° Gateway ONE PNET-1 ONE Optional FPT-GATE-3 Extender Plate ONE Page 4 of 5 — 9020-0649:X E3 SERIES° CABINETS TECHNICAL SPECIFICATIONS STANDARDS The E3 Series fire alarm control panel cabinets are designed to comply with the following standards: UL Standards: UL 864,10th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non -coded and Master Coded Operation Underwriters Laboratories Standard UL 2572, 2nd Edition (for Mass Notification Systems) UUKL for Smoke Control NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16-Standard for Foam -Water Sprinkler and Foam Water Spray Systems NFPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry Chemical/17A Wet Chemical Seismic Codes International Building Codes: IBC 2013 IBC 2009 IBC 2006 IBC 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com STANDARDS (CONTINUED) The E3 Series Cabinets are designed to comply with the following standard: UL Standard: UL 864, loth Edition UL 2572, 2nd Edition for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: 51869 ULS 864, loth Edition UL 2572, 2nd Edition M EA Approved: 6177 MEA FDNY: COA# 6077 CSFM: 7165-1703-0125 FM Approved: 3025415 City of Chicago City of Denver VMA Seismic Certified ISO 9001 Certification 9020-0649 1 X 1 06/20 ©2020 Honeywell International Inc. Honeywell �Gerr�.wei A"Clan 4y;'KP Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable monitor module AMM-21F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end -of -line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.C.) dry con- tacts may be made addressable when connected to the AMM-21F module. The Velociti® Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-21F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Velociti is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. VelocitiO Series ANN111111112F Addressable Monitor Module f AMM-2F Features • Compact size allows easy installation • Class B, Style B, initiating circuit • 40 Ohm line resistance for each initiating device circuit • Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32° to 120' F (0° to 49' C) Relative Humidity: 10 to 93% (non -condensing) End -of -Line Resistance: 47K ohms Dimensions: 1.3" L x 2.5" W x 0.5" D (3.3 x 6.4 x 1.3 cm) Ordering Information Part Number Description AMM-21F Addressable monitor module, single circuit, Style B, Class B An ISO 9001-2000 Company SIGNALING �L FM MEA I'?� I LISTED APPROVED Approved S1949 3023594 227-03-E VOL IV 7300-1703:102 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. D1 page 1 of 1 Honeywell I Addressable Devices QGamewell m Velociti° Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capabilitythat enable each detector address to be setwith rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re -designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi - sensor detector offers either photoelectric detection orthermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti" and CLIP" protocols, the GWF-7075 panel does not supportthe CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° Standard 268 7th Edition • Designed with anew profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current Photoelectric Detector • Provides rotary address • Includes dual LEDs for • Offers expanded color switches(01-159) 3601visibility options • Supplies optional relay, isolator, or sounder bases (standard or low frequency) Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: '-BC suffix indicates Black color model. NOTE: "WH° suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensinq, bri htwhite Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases Ford eta its on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates brightwhite B501-WHITE: 4" Flangeless mounting base, bright white B501-WHITE-BP: 4"Flangeless mounting base bulk pack, brightwhite B501-IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, brightwhite B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non -relay DNRW: Intelligent duct detector housing, non -relay, watertight 7 Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 320 F to 1220 F (00 C to 500 C) Photo in Duct Applications: -4° F to 158' F (-20° C to 70' C) Photo with Thermal: 32' F to 1001 F (01 C to 381 C) Operating Humidity Range: 10%to 93% non -condensing Rate -of -Rise Detection: Responds to greater than 150F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA C 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA C 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti° Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The Velociti° Series 3 Photoelectric Detectors are certifications, please visit: designed to comply with the following standard: http://www.gamewell- UL Standard: UL 268 fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules E3 Series°,Velociti® and specified in this document. In some cases, certain Gamewell-FCI® are registered modules or applications may not be listed by certain trademarks of Honeywell approval agencies, or listing may be in process. International Inc. Consult factory for latest listing status. UP is a registered trademark UL: S2332 of Underwriter's Laboratories FM: 3023594 Inc. M EA FD NY: COA-219-02-E Vol. VI This document is not intended CSFM: 7272-1703:0501 to be used for installation ISO 9001 Certification purposes. Wetryto keep our product information up-to- date and accurate. We cannot coverall specific applications or anticipate all requirements. Allspecifications are subjectto change without notice. K 04/2018 @2018Hon Honeywell ©2018 Honeywell International Inc. NT B Standard, Relay, Isolator, Sounder, and Low Frequency Sounder Bases To meet local code and application requirements, Gamewell-FCI° offers standard 4" and 6" bases, as well as specialty base designs including relay, isolator, sounder and low frequency E sounder bases that are UL listed for low frequency operation and comply with NFPA 72 ° ��J requirements for sleeping spaces for the new Gamewell-FCI Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent — systems, with screwterminals provided for power (+ and —), and remote annunciator B300-6 Standard 6" B20OS-WHSounder connections. Communication takes place over the power (+ and —) lines. The 4" base offers a Base (White) Base (White) compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface - mount boxes. The mounting plate enables pre -wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-IV) provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two --- different modes (short and long delay). The activation time for the short delay is 60-100 B501-WHITE Flangeless B501-BL Flangefess milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin 4" Base (White) 4" Base (Black) headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224B1-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/-10%with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most idealto wake sleeping occupants, even those with mild to severe hearing loss. FEATURES AND BENEFITS • Bases enable quick and secure detector plug-in • SEMS Screws provide easy wiring connection • UL 268 compliant • Support for 12-24 AWG provides installation flexibility • Multiple base formats meet application requirements • Standard white colorwith ivory and black options • Mechanical locking feature restricts removal of attached sensor head • Specialty Base Features: • Pre -wired mounting plate simplifies installation • Application driven feature sets • Sounder bases both UL268 and UL464 compliant Honeywell Oft The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/ B224RB-IV: Ivory, relay base B200S-LF-WH/B200S-LF-IV) adopt the same address as the B224BI-WH: White, isolator detector base detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder— or a group of sounders —to activate. The command set from the FACP can be tailored to multiple event - driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200SR sounder and LF sounder bases (B200SR-WH/ B200SR-IWB200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. PRODUCT LINE INFORMATION INTELLIGENT BASES "-IV" suffix indicates Ivory color model. "-BL" suffix indicates Black color model. "-WH" and "-WHITE" suffix indicates White color model. B21OLP: Flanged mounted base. B21OLPA: Same as B210LP; ULC listed. B21OLPBP: Bulk pack of B210LP, contains 10. B224B1-IV: Ivory isolator detector base B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti® protocol B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti° protocol B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement; intended for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applications. B300-6: White, 6" base, standard flanged low -profile mounting base MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of 3300-6, package contains 10 TR300: White, replacement flange for B210LP, B300-6 base B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. TR300-IV: Ivory, replacement flange for B210LP, B300-6-IV base B501-WHITE: White, 4" standard European flangeless mounting RA10OZ: Remote LED annunciator, 3 - 32 VDC, mounts to a U.S. base. UL/ULC listed single -gang electrical box; For use with B501 and B300-6 B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B501-BL: Black, 4" standard European flangeless mounting base B501-IV: Ivory color, 4" standard European flangeless mounting base B224RB-WH: White, relay base JUNCTION BOX SELECTION GUIDE M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Square 4.0" Square with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Applies to all model variants "BU, "-LF", "-IV", "-WH", and "-WHITE". See Product Line Information for detailed model description. Page 2 of 3 — 9021-60540:K • 7/8/2019 INTELLIGENT BASES TECHNICAL SPECIFICATIONS ELECTRICAL For B300-6 Series bases: • Operating voltage: 15 to 32 VDC • Standby current:170 pA maximum For B501 Series bases: • Operating voltage: 15 to 32 VDC • Standby current:150 pA maximum For B200 Series bases: • External supply voltage:16 to 33 VDC (FWR) • Standby current: 500 pA maximum • Alarm current for B200S(-IV)(-WH): 35 mA maximum at high -volume setting 15 mA maximum at low -volume setting • Alarm current for B200S-LF(-IV)(-WH) High - volume setting: 70 mA maximum 33.0 VDC 90 mA maximum 24.0 VDC 140 mA maximum @16.0 VDC • Alarm current for B200S-LF(-IV)(-WH) Low - volume setting: 15 mA maximum C 33.0 VDC 20 mA maximum @ 24.0 VDC 25 mA maximum @ 16.0 VDC • Alarm current for B200SR(-IV)(-WH): 35 mA maximum • Alarm current for B200SR-LF(-IV)(-WH): 65 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 125 mA maximum @16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: Greaterthan 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) For 13224BI, B224RB (-IV) (-WH) bases: • Operating voltage: 15 to 32 VDC (powered by SLC) • Standby ratings: <450 pA maximum C 24 VDC • Set time: (13224RB(-IV)(-WH) only): short delay 60-100 msec; long delay 6-10 seconds • Reset time: (B224RB/-IV/-WH only): 20 milliseconds maximum • Relay characteristics: (B224RB/-IV/-WH only): two -coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9AC 110VDC, and 3.0AC 30VDC PHYSICAL Note: Specifications applies to all modelvariants "-BL'', "-LF", "-IV", -WH, -WHITE. See Product Line Information for detailed model description. Diameter: • B501-WH ITE: 4" (10.16 cm) • B300-6, B210LP: 6.1" (15.49 cm) • 1322413I, B224RB: 6.2" (15.748 cm) • B200S, B200SR: 6.875" (17.46 cm) Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com Wire gauge: • 1322413I, B224RB: 14 to 24 AWG • B300-6,B210LP,B501,B200S,B200SR12to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR: 32°Fto 120°F (0°C to 49°C) • B300-6, B210LP, B501: -4°F to 150°F (-20°C to 66°C) Humidity range: 10%to 93% RH, non - condensing System temperature and humidity ranges: This system meets NFPA requirements for oper- ation at 0°C to 49°C (320F to 120°F); and at a relative humidity (non -condensing) of 85% at 300C (86°F) per NFPA, and 93%± 2% at 320C ± 2°C (89.61F± 1.1°F) per ULC. However, the use- ful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended thatthis system and all peripherals be installed in an environmentwith a nominal room temperature of 15°C to 27°C (60°F to 80°F). AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S911 FM Approved CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0238 9021-60540 1 K 1 07/19 ©2019 Honeywell International Inc. Honeywe QGamewell Analog and Networking Systems E3 Series"' Cabinets Cabinets used for the E3 Series General The E3 Series° Expandable Emergency Evacuation System by Gamewell-FCI offers several cabinet size options. The E3 Series System is a modular design that allows a wide range of configurations to form an integrated, distributed fire alarm system. These cabinet options allow for sturdy and modern installations. The E3 Series cabinet assembly is a compact, wall -mounted enclosure. A typical cabinet includes a backbox and an outer locking door. In addition, there are several inner door options and mounting plates to accommodate a variety of E3 Series sub -assemblies. Each cabinet backbox includes mounting patterns for plates to allow the installer to arrange and secure the sub -assemblies to the backbox. The backbox knockouts are also positioned at numerous points to allow a conduit access into the enclosure. The following four Annunciator cabinet sizes provide the maximum flexibility that can meet any application. • Cabinet AA offers 2-slot or 3-slot options to accommodate any of the following configurations: — Inner door, 2-slots allows space for one LCD-E3 or LCD-SLP and one ASM-16 — Inner door, 3-slots allows space for any combination of three modules: ASM-16, NGA or an ANU-48 • Cabinet Al houses one NGA or one ASM-16/ANU-48. • CabinetA2 accommodates a single _CD-E3. • E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. The E3BB-R-BSlim or B-Slim contains the 600 Series cabinet. Cabinet B includes a mounting plate that contains a space for the following modules: • ILI-MB-E3/ILI95-MB-E3 • PM-9/PM-9G sub -assemblies • Batteries set inside the backbox Additional sub -assembly options mounted on the backbox include the DACT-E3 and RPT-E3. The 2-slot inner door houses the following options: • one LCD-E3 module and• either one ASM-16/ANU-48 or one NGA module FEATURES & BENEFITS • IBC Seismic Certified • 16-gaugesteel backbox • Contains removable outer and inner doors • Lexan° windows appear on the doors of most cabinets, except the Cabinet "C" and "D" INX cabinets and the INX CAB-B cabinet which contain louvered doors • Builtwithaninner door bonding strap used to provide electrical continuity for grounding • Cabinets are available in either black or red E3 Series' Cabinets • Backbox and door ground studs provide positive grounding, and 1801 opening door with full clearance • Offers 901 opening door with zero clearance • Includes a keylock with quarter turn latch • Trim Ring accessories available General Both the C and D-size Command Center cabinets house a variety of E3 Series Broadband sub- assemblies thatcan be used in multiple configurations that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and D-size Command Center cabinets that may contain any of the following: • fire fighter's phone handset • microphone • optional modules to meet the facility operation requirements Refer to the Inner Door and Backbox Mounting Capacities in the Ordering Information Section. Ordering Information Inner Door Mounting Capacity Part Number Description Cabinet "AA" Size Dimensions: 191/4" W x 10" H x 41/2" D (49 W x 25 H x 11.4 D cm) E3BB-BAA Enclosure, Black,"AA"(LOC)Size E3BB-RAA Enclosure, Red, "AA" (LOC) Size E31D2-TA Inner Door, 2-slots (INCC-TEL&ASM-16) E31D2-A Inner Door, 2-slots (LCD-E3 or LCD-SLP & ASM-16) E31D3-A Inner Door, 3-slots (NGA, ASM-16 and MIC) Cabinet "W" Size: Dimensions: 8 3/4" W x 10" H x 41/2" D (22 W x 25 H x 11.4 D cm) E3BB-BAA1 Remote Enclosure, Black, w/Inner Door, 1 slot, (NGA) E3BB-RAA1 Remote Enclosure, Red, w/Inner Door, 1-slot, (NGA) Cabinet 12" Size: Dimensions: 131/4" W x 10" H x 41/2" D (40 W x 2 5 H x 11.4 D cm) E31313-BA2 Remote Enclosure, Black, w/Inner Door, 1-slot, (LCD-E3 or LCD-SLP) E3BB-RA2 Remote Enclosure, Red, w/Inner Door, 1-slot, (LCD-E3 or LCD-SLP) Flush Cabinet A2 Annunciators: Dimensions: 131/4" W x 10" H x 41/2" D E3BB-FLUSH-LCD CAB A2 Remote Flush LCD ANN with Key switch o eration E3BB-NGA-FLUSH CAB A2 Remote Flush NGAANN with Password protected Cabinet "B-Slim" Size: (Retrofit Kits) Dimensions: 14" W x 20" H x 41/2: D (35.5 Wx 50.8 H x 11 D cm) E3BB-RBSLIM Assy, Enclosure, B-SLIM, Red with Backplate and _CD-E3 Keyswitch plate IF600-RETROFIT Door and Cab mounting plates, disable key switch and door lock (PK-625) for E3 Series upgrade. Cabinet "B" Size: Dimensions: 19 3/8"W x 19 3/8"H x 41/2"D (49 W x 49 H x 11 D cm) E3BB-BB Assy, Backbox Enclosure, Black,"B"Size E3BB-RB Assy, Backbox Enclosure, Red, "B" Size E31D2-B Inner Door, 2-slots, "B" Size 1100-0458 B Size INCC Command Center enclosure, black 1100-0459 B Size INCC Command Center enclosure, red door 1100-0460 INX-Transponder 19" (cm) Backboxwith Door, Black Ordering Information (Continued) Part Number Description Cabinet "B" Size (Continued) Dimensions: 19 3/8"W x 19 3/8"Hx41/2"D (49 W x 49 H x 11.43 D cm) Cabinet "C" Size: Dimensions: 19 3/8" W x 30" H x 41/2" D (49 W x 76 H x 11 D cm) E3BB-BC/INCC Enclosure, Command Ctr, Black, "C" Size E3BB-RC/INCC Enclosure, Command Ctr, Red,"C"Size E31D2-C Assy, Inner Door, Command Ctr.2- Bay"C"Size E31D3-C Assy, Inner Door, Command Ctr, 3-Bay"C"Size E3BB-BC/INX Assy, Transponder, Black, "C" Size E3BB-RC/INX Assy, Transponder, Red, "C" Size E3-INCC-CPLATE Command Center module mounting plate,"C" Size E3-INX-CPLATE Transponder mounting plate, "C" Size Inner Door Mounting Capacity E3-ILI-CPLATE Intelligent loop module mounting plate 'C" Size Cabinet "D" Size: Dimensions: 19 3/8" W x 41" H x 41/2" D (49 W x 104 H x 11 D cm) E3BB-BD/INCC Enclosure, Command Ctr, Black, "D" Size E3BB-RD/INCC Enclosure, Command Center, Red, "D" Size E31D2-D Assy, Inner Door, 2-Bay, "D" Size E31D3-D Assy, Inner Door, 3-Bay, "D" Size E3BB-BD/INX Enclosure, Transponder, Black "D"Size E3BB-RD/INX Enclosure, Transponder, Red, "D"Size E3-INCC-D-PLATE Command Center module mounting plate, "D" Size E3-INX-D-PLATE Transponder module mounting plate, "D" Size Optional Extender Plates AM-50 Plate AM-50 Extender Plate FPT-GATE-3-EXT FPT-GATE-3 Extender Plate Optional Accessories 1100-0450 Command Center, blank plate, single size E3-BP Inner door panel, blank, double size 90375 PM-9/PM-9G Adapter Plate Kit,Hardware E3-TRIMKIT-A Trim kit for "A"/"AA"size enclosure, black E3-TRIMKIT-Al Trim kit for "AAl"size enclosure, black E3-TRIMKIT-A2 Trim kit for"A2"size enclosure, black E3-TRIMKIT-B Trim kit for "B"size enclosure, black E3-TRIMKIT-C Trim kit for "C"size enclosure, black E3-TRIMKIT-D Trim kit for "D" size enclosure, black Bulk Amplification AA-100 100 W Audio Amp.@70.7 VRMS w/120 VAC AA-120 120 W Audio Amp. @25 VRMS w/ 120 VAC ACT-1 Audio coupling transformer, for audio systems w/multiple supplies FCI-CHG-120 Battery Charger, 25-120 A/H Gel cell FCI-LBB Battery box, accommodates batteries up to 55 A/H, (Black) Cabinet C: FCI-DR-C4B Large Battery Backbox,blankdoor,lockand keys for backbox accepting 3 chassis, (Black) FCI-DR-C4BR Blank door, lock and keys, for backbox accepting 3 chassis, (Red) SBB-C4 Backbox, 3 chassis, (Black) Cabinet D: FCI-DR-D4B Blank door, lock and keys, for backbox accepting 4 chassis, (Black) FCI-DR-D4BR Blank door, lock and keys, for backbox accepting 4 chassis, (Red) SBB-D4 Backbox, 4 chassis, (Black) 90516 7100-Slim 7A/H Seismic Battery Bracket Kit Seismic Battery Bracket Kits Part Number Description E3 B-Slim 7 A/H Seismic Battery Bracket Kit 90517 7100-Slim 12 A/H Seismic Battery Bracket Kit E3 B-Slim 12 A/H Seismic Battery Bracket Kit 90518 E3 CAB-B 7 A/H Seismic Battery Bracket Kit Ordering Information (Continued) Seismic Battery Bracket Kits (Continued) Part Number Description E3 CAB-C 7 A/H Seismic Battery Bracket Kit E3 CAB-D 7 A/H Seismic Battery Bracket Kit NetSOLONS-INX-7A/H Seismic Battery Bracket Kit NetSOLO-7100-7A/H Seismic Battery Brckt Kit 90519 E3 CAB-C (INX only)12 A/H Seismic Battery Bracket Kit E3 CAB-D (I NX only)12 A/H Seismic Battery Bracket Kit NetSOLO NS-INX 12 A/H Seismic Battery Bracket Kit 90520 E3 CAB-B 18 A/H Seismic Battery Bracket Kit E3 CAB-C 18 A/H Seismic Battery Bracket Kit E3 CAB-D 18 A/H Seismic Battery Bracket Kit Retrofit Kits For information on the Gamewell and 7200 Retrofit Kits, referto the following Data Sheets. 9021-60678 Gamewell Retrofit Kits Data Sheet 9021-60733 7200 Retrofit Kits Data Sheet Inner Door Mounting Capacity Part Number Components Cabinet AA E31D2-A Cabinet AA, InnerDoor, 2-slats 1 -CD-E3 Display and 1 ASM-16/ANU-48 E31D2-TA Assembly, Door, Inner, TEL-E3 E31D3-A, Cabinet A, Inner Door, 3-slots 1 NGAorASM-16 2 ASM-16s/ANU-48 Cabinet AAl E31D-Al Cabinet AA1,InnerDoor (Includes Box) 1 NGAorASM-16 Cabinet A2 E31D-A2 CabinetA2, Inner Door, (Includes Box) 1 -CD-E3 Cabinet B E31D2-B Cabinet B, Inner Door, (Includes Box) 1 LCD-E3 Display and one ASM-16/ANU-48 1 NGA and one ASM-16/ANU-48 B-Slim Cabinet 1 -CD-E3 Display & one RPT-E3 or one DACT-E3 1 ILI-MB-E3 or one ILI95-MB-E3 1 PM-9 or one PM-9G Cabinet C E31D2-C Cabinet C, Inner Door, 2-slots 1 -CD-E3 Display and 5 Any combination of ASM-16/ANU-48,NGA or Microphone Assemblies 1 Telephone Assembly E31D3-C Cabinet C, Inner Door, 3-slots 7 Any Combination of ASM-16/ANU-48,NGA, or Microphone Assemblies 1 Telephone Assembly Cabinet D E31D2-D Cabinet D, Inner Door, 2-slots 1 -CD-E3 Display 11 Any Combination of ASM-16/ANU-48, or NGA or Microphone and 1 Telephone Assembly E31D3-D Cabinet D, Inner Door, 3-slots 13 Any Combination of ASM-16/ANU-48,NGA or Microphone Assemblies 1 Telephone Assembly 1 Loop Interface orANXor 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Backbox Mounting Capacity E3BB-BAA Enclosure'AA'(LOC)Size Black 1 I NI -VG Series Voice Gateway E3BB-BAA1 AAl Size Box/Door, Black 1 RPT-E3 Network Repeater E3BB-BB B-Size Box/Door, Black 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3/ILI95-MB-E3 and Backbox Mounting Capacity (Continued) Part Number Components E3BB-BB B-Size Box/Door, Black 1 Additional ILI-MB-E3/ILI95-MB-E3 1 Loop Interface orANXor 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater INX CAB-B Mounting Plate 1 PM-9 or PM-9G 1 INI-VGX 4 AM-50Series amplifiers E3-INCC-C Plate 1 PM-9/PM-9GPower Supply 1 INI-VG Series Voice Gateway 1 ILI-MB-E3/ILI95-MB-E3 Loop Interface and Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 OptionalAM-50 or FPT-GATE-3 Extender Plate E3-ILI-C Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 2 Additional ILI-MB-E3/ILI95-MB-E3 or I LI-S-E3/ILI95-S-E3 or ANX 1 DACT-E3 1 RPT-E3 1 Optional FPT-GATE-3 Extender Plate E3-INX-C Plate 1 PM-9/PM-9G PowerSupplywith one PM-9/PM-9G Adapter Plate 1 INI-VGXVoice Gateway 1 ILI-MB-E3 Loop Interfaceand 1 AdditionallLI-MB-E3/LI95-MB-E3/ANX 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 4 AM-50SeriesAmplifier 1 Optional FPT-GATE-3 Extender Plate E3-INCC-D Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 4 Additional lLI-E3orIL195-E3Series orANX 1 DACT-E3Digital Communicator 1 RPT-E3 Network Repeater 1 INI-VG Series 1 OptionalAM-50 or FPT-GATE-3 Extender Plate E3-INX-D Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 1 DACT-E3Digital Communicator 1 RPT-E3 Network Repeater 1 INI-VG Series 4 AM-50SeriesAmplifier 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center (Voice), Black 1 PM-9/PM-9GPower Supply 1 INI-VG Series Voice Gateway 4 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface 1 Additional ILI-MB-E3/ILI95-MB-E3/ ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center, Black 1 PM-9/PM-9G Power Supply 7 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface & Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Optional Extender Plates AM-50 Extender Plate 1 AM-50-25 or AM-50-70 FPT-GATE-3 Extender Plate 1 FocalPoint® Gateway 1 PNET-1 1 Optional FPT-GATE-3 Extender Plate E3 Series"' Cabinets Technical Specifications STANDARDS The E3 Series fire alarm control panel cabinets are designed to comply with the following standards: UL Standards: UL 864 9th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non -coded and Master Coded Operation Underwriters Laboratories Standard UL 2572 (Mass Notification Systems). UUKLfor Smoke Control UL25721st Edition NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16 - Standard for Foam -Water Sprinkler and Foam Water Spray Systems N FPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 N FPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist N FPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry ChemicaV17A Wet Chemical Seismic Codes International Building Codes: IBC 2013 IBC 2009 IBC 2006 IBC 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) For more information Learn more about Gamewell-FCI's E3 Series® Cabinets and other products available byvisiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The E3 Series Cabinets are designed to comply with the certifications, please visit: following standard: http://www.gamewell- UL Standard: UL 864 9th Edition fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules E3Series°, FocalPoint°and specified in this document. In some cases, certain Gamewell-FCIo are registered modules or applications may not be listed by certain trademarks of Honeywell approval agencies, or listing may be in process. Consult International Inc. factory for latest listing status. . Lexano Is a registered UL Listed: S1869 trademark of GE Plastics, a MEA Approved: 6177 subsidiary of General Electric Fire Dept. of New York: COA# 6077 Company. CSFM: 7165-1703-0125 UL° is a registered trademark FM Approved: 3025415 of Underwriter's Laboratories City of Chicago Inc. City of Denver This document is not intended VMA Seismic Certified to be used for installation ISO 9001 Certification purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. @2018Hon w 06/18 Honeywell ©2018 Honeywell International Inc. HPFF12, HPFF12CM, HPFFI2E, HPFF12CME NAC Expander/Power Supply Description The Honeywell HPFF12 and HPFF12CM are Notification Appliance Circuit (NAC) Expander Power Supplies designed to extend the power capabilities of existing NACs and provide power for auxiliary devices. The HPFF12 and HPFF12CM con- nects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. They provide regulated and filtered 24VDC power to four NAC's and an auxiliary output. The NAC outputs are rated at 3.0 amps each and the auxiliary output is rated at 2.0 amps (this output is continuously supplied, even in alarm, and there- fore must be taken into account for power supply loading and battery size calculations). The combined output cannot exceed 12.0 amps. The HPFF12 and HPFF12CM provide independent output cir- cuit supervision so in the event of a NAC fault they can notify the attached FACP. In addition they have a trouble memory feature that displays past troubles (by NAC) for rapid diagnos- tics. Synchronization is built in for five appliance brands. The HPFF12 and HPFF12CM have two fully independent supervised initiating circuits that can be used for synchronized strobes and coded horns. Their NAC outputs may be config- ured as any of the following: • four Class B (Style Y) • two Class A (Style Z) • two Class B and one Class A • four Class A with the optional HPP31076 Class A adapter These power supplies contain an internal Battery charger capable of charging up to 26.0 amp -hour (AH) batteries. The HPFF12 is mounted in a lockable wall cabinet that can accommodate up to two 18AH batteries. The HPFF12CM is designed to mount in Honeywell's large equipment enclosure (EQBB-D4; order separately). Up to three HPFF12CM sup- plies can be mounted in an EQBB-D4 in positions 2, 3, and 4. Each HPFF12CM can accommodate two 12AH batteries. One of the most challenging aspects of a retrofit application is locating the existing End -of -Line (EOL) resistor. In these appli- cations that have EOL values other than the 3.9k normally used with the HPFF12, a single resistor matching the existing EOL can be used as a reference for all the outputs. This fea- ture speeds installation and system checkout because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. NOTE: 4 separate programming resistors for the HPFF12 are pro- vided in the hardware kit shipped with each HPFF12 and HPFFB. They are 3.9K (5 of these are provided, need only 1 for program- ming), 2.2K (1 each), 4.7K (1 each) and 10K (1 each) Features • Four (4) power limited supervised notification application circuits (NAC's) capable of supplying +24VDC at 3.0 amp maximum each. • NAC output circuits may be configured as any of the follow- ing: — Four Class B (Style Y). — Two Class B & one Class A. Honeywell HPFF12CM: Three modules in EQ1313-134 — Two Class A (Style Z). — Four Class A (requires the HPP31076 Class A adapter). • Four field -programmable operational modes: — Pass -through. — Temporal generator. — Sync generator. — Pass -through Filtered. • Temporal coding and sync protocols compatible with the fol- lowing notification appliance brands: — System Sensor. — Faraday. — Amseco. — Cooper -Wheelock. — Gentex. • Protocol pass -through for synchronizing large systems. • Two fully independent supervised input/output control circuits. • Redundant activation operation for survivability. • Supports FACP's Selectable Silence ability. • 2.0 amp auxiliary continuously supplied output. • Eight status LEDs. • Complies with UL 864 9th Edition. • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults. • Trouble indication for supervision of the following: - NAC circuits. - Auxiliary output. - AC input. - Battery charger voltage. - Earth ground faults. • Optional two-hour delay for AC loss. • Separate Trouble and AC Fail Form-C relay contacts. • The Trouble Form-C relay contacts selectable for immediate or a 2 hour delay with AC failure. • 26 AH battery charger capability; wall cabinet supports two 12V 18AH batteries, while the Multi -pack equipment cabi- nets supports two 12V 12AH batteries. • NAC Overload protection and indication. • Provision for mounting single or 6 circuit addressable con- trol or relay modules inside the enclosure. (Use mounting kit PN 90475.) Specifications Primary Input Power: 120VAC, 60Hz, 5.4A standard; 240VAC, 50Hz, 3.2A on units with E suffix. Secondary Power: 24 volt operation: two 7-24 AH batteries. Battery Charging Capacity: Up to 26 AH batteries. HPFF12 Cabinet: Holds up to two 18AH batteries. HPFF12CM: Holds up to two 12AH batteries. Total Output Current: 12.OA max. Standby Current: 0.075 A. Auxiliary Power Output: 2.OA under all conditions. NAC Output Ratings: 24VDC fully regulated, 3.OA max per circuit (8.OA total). End -of -Line Resistor Range: 1.9K to 25k ohm,'/2 watt. Prod- uct ships with 4 separate programming resistors. They are 3.9K (5 each - only need one for programming), 2.2K (1 each), 4.7K (1 each) and 10K (1 each) Common Trouble: 2.OA at 30VDC. Relay Fail Relay: 2.OA at 30VDC. Input Control Circuits: compatible with 12 and 24 VDC con- trol panel NACs. Input Control Current (alarm): 5.68 mA @ 12 VDC, 12.28 mA @ 24 VDC. Temperature Rating: 32°F to 120°F (OoC to 49°C). Relative Humidity: 10% to 93% non -condensing. Cabinet Dimensions: • HPFF12 Cabinet: 16.65" W x 19.0" H x 5.2" D (42.29 W x 48.26 H 13.23 D cm) • Large equipment enclosure (EQBB-D4): 24" W x 45.9" H x 5.15" D (60.96 W x 116.52 H x 13.1 D cm) Product Line Information HPFF12: 12.OA fire rated power supply. Unit includes red enclosure, battery cable and installation instructions. 120VAC/ 60Hz. HPFFI2E: 240VAC/5OHz version of HPFF12. HPFF12CM: 12.OA fire rated power supply (chassis mounted). Unit includes mounting hardware, battery cable and instruc- tions for installation in large equipment enclosure. 120VAC/ 60Hz. HPFF12CME: 240VAC/5OHz version of HPFF12CM. HPP31076: Class A (Style Z) NAC Adaptor. Increase Class A circuits from 2 to 4. Large Equipment Enclosure: EQ series cabinet for mounting HPFF12CM power supplies consists of a backbox (EQBB-D4) and a locking door (EQDR-D4 or FCI-VDR-D4B). CMF-300-6: Six -circuit supervised addressable control mod- ule activated through FACP programming on a select basis to control power supply activation or output. CMF-300: Supervised addressable control module activated through FACP programming to activate power supply. BAT-12120: Battery, 12 volt, 12.0 AH (two required). BAT-1270: Battery, 12 volt, 7.0 AH (two required). 90474: Mounting kit; required to attach an addressable mod- ule onto the control circuit board (included with supply). Listings and Approvals Listings and approvals are in process, to comply with UL 864 9th Edition. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Notifier® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com DH-60547:6 December 2009 Made in the U.S .A. O U.S. Registered Trademark IVO 9001 02009 Honeywell International Inc. ENGINEERING RMANUFACTURING - Page2of2 QUALITY SYSTEMS INImVG! Intelligent Network Interface Voice Gateway The INI-VG Series is a network audio and command control interface used with the E3 Series° and Voice Evacuation Systems. GENERAL The INI-VG Series (Intelligent Network Interface -Voice Gateway) is a network interface with superior Audio and Command/ Control that is used for E3 Series fire alarm and Voice Evacuation Systems. The modular design allows the INI-VG Series to be used in any type of system configuration to function as a voice network interface for any of the following: • Fire Command Center • Digital Audio Voice Transponder • Analog Audio Voice Transponder • Autonomous Control Unit (ACU) for Mass Notification • Local Operating Console (LOC) for Mass Notification With a Class B signaling line circuit (SLC), the INI-VG can monitor and control up to sixteen AOM-TELF telephone modules to use with the fire fighter telephones or serve as value Local Operating Consoles (LOC). In addition, it can support up to 16 AOM-2SF, signal output modules that can be used for distributed audio control. Networked through single -mode fiber optics, multi -mode fiber optics, and/or twisted -pair wire, the INI-VG Series resides on the E3 Series and/or S3 Series network, represented as a node with fully independent control. Each INI-VG Series provides its own internal recorded message storage that operates as a redundant back-up in case another panel is no longer functional. Each version of the INI-VG Series features a unique functionality that can operate as any of the following, depending on how each version is used with the application: • Digital Audio Voice Transponder(INI-VGX) connects up to three main amplifiers and one back-up amplifierto control over 150 watts of audio per board. • Analog Audio Voice Transponder(INI-VGE) connects to analog bulk amplifiers and distributes audio using 16 AOM-2SF modules. • Fire Command Center (INI-VGC) connects hand-held microphones and main fire fighter telephones. FEATURES AND BENEFITS • Listed under UL° Standard 864, loth Edition • Listed under UL Standard UL2572, 2nd Edition for Mass Notification • Supports a network data transfer rate at 625K baud • Controls all communication signals and control -by -event sequences over twisted, unshielded pair of wires or fiber-optic cable • ALL INI-VGSeries Modules connecttoavoice page microphone and fire fighter's handset • Uses advanced Digital Signal Processor (DSP) technology that provides efficient audio compression and filtering • Offers the following fiber-optic plug-in modules used for fiber-optic connectivity - FML-E3 (fiber-optic multi -mode) - FSL-E3(fiber-optic single -mode) INI-VG Series • Supports Distributed Architecture, including Class Xwiring configuration, that allows system components to continue normal operation with NO loss of function during single line fault conditions • Provides Redundant Command Centers with a microphone and a fire fighter's handset which can easily be configured by adding INCCs Honeywell h0n' INI-VGC The INI-VGC Voice Gateway Module is optimized to provide command and controlfunctions forthe INCC Command Center. The INCC serves as the point of interface between an operator and the system's audio evacuation, fire fighter intercom, and building control circuits. A typical INCC assembly consists of the following: • an Intelligent Network Interface -Voice Gateway (INI-VGC) Module • one or more Addressable Switch Modules (ASM-16) • a Voice Page Microphone (INCC-MIC) Each INI-VGC can support up to 16 ANU-48 LED Driver Modules or ASM-16s for a total of 256 fully programmable switches and 768 LEDs that light in red, yellow, and green. The INI-VGC occupies a single node on the E3 Broadband network and it is connected by a single, pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INCC Command Center's INI-VGC module also provides connections for an optional fire fighter telephone handset. The INI-VGC is a fully digital voice/tone generator using state-of-the- art Digital Signal Processing (DSP) technology to produce superior audio signals. The INI-VGC provides an output to a local speaker for message verification and testing. INI-VGE The INI-VGE Voice Gateway Module provides an audio interface to the bulk analog amplifiers and command and control functions for the INCC Command Center. A typical INCC assembly consists of the following: • an Intelligent Network Interface -Voice Gateway (INI-VGE) Module • one or more Addressable Switch Modules (ASM-16) • a Voice Page Microphone (INCC-MIC) Each INI-VGE can support up to 16 ANU-48 LED Driver Modules or ASM-16s for a total of 256 fully programmable switches and 768 LEDs that light in red, yellow, and green. The INI-VGE occupies a single node on the E3 Series Classic network and is connected bya single pairof twisted, unshielded wire, fiber-optic cable or any combination of the two. The INCC Command Center's INI- VGE module also provides connections for an optional fire fighter telephone handset.The INI-VGE's one Signaling Line Circuit(SLC) loop supports the following: • 16 remote Fire Fighter Phones • 32 Supervised Audio Control Relays The INI-VGE is a fully digital voice/tone generator using state-of-the- art Digital Signal Processing (DSP) technology to produce superior audio signals. The INI-VGE provides an audio output capable of driving up twenty 100 watt (AA-100) or 120 watt (AA-120) amplifiers. INI-VGX The INI-VGX Transponder Voice Gateway is a component of the E3 Broadband Audio Evacuation System and an optional component of the E3 Series Expandable Emergency Evacuation System. It is a multi- function module that incorporates the following: • Software -programmable multi -channel digital audio applications. • One Class B Signaling Line Circuit (SLC) supporting up to 32 addressable speaker circuits (AOM-2SF) and 16 addressable phone circuits (AOM-TELF). • Supports up to 150 watts of audio power (using the AM-50 Series amplifiers operating at 50 watts of power @ either 25VRMs or 70.7VRMS output) with backup amplifier support. • Offers a sixteen message capacity with up to minute total duration per INI-VGX. The messages are easily field -configured via a laptop computer. • Network interface using twisted, unshielded wire or fiber-optic cable • Local fire fighter phone riser. The INI-VGX provides command and controlfor up to fourAM-50 Series amplifiers, operating at 50 watts of power C either 25VRMs or 70.7VRM audio output (up to 150 W of audio may be delivered at any given time). The amplifiers are installed in a single cabinet. The INI-VGX uses advanced Digital Signal Processing (DSP) technology for audio compression and filtering. This feature allows the E3 Series Broadband System to produce superior clarity for intelligible LIVEvoice paging.The background noise is automatically filtered during voice paging and fire fighter communications which increases the audibility and eliminates the need for Push -to -Talk devices. Page 2 of 3 — 9020-0648:K INI-VG SERIES TECHNICAL SPECIFICATIONS SPECIFICATIONS INI-VGC, INI-VGE and INI-VGX: Operating Voltage: 24VDC (nominal)from the PM-9/PM-9G Power Supply Operating Current: 0.150 amp. supervisory and alarm Operating Temperature: 32 -1200 F (0 - 490 C) Relative Humidity: 0 to 93% (non -condensing) Supervised Class 2 Power -Limited Protocol: Asynchronous with half -duplex data flow Wiring Specifications: INI-VG Series (Third Generation Voice Gateway and Legacy-UTP Models): Copper Wire: 16 to 18 AWG twisted -pair, unshielded. Up to 3,000 ft. (914.4 m) between each node. Fiber -Optic Cable: FML-E3 (Multi -Mode): Up to 200 microns (optimized for 62.5/125 microns). Up to 8dB loss between each node. FSL-E3 (Single -Mode): Up to 1310nm (nanometer) (optimized for 9/125microns). Up to 30dB loss between nodes. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% PH (non - condensing) at 32°C±2°C (90°F±3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com ORDERING INFORMATION INI-VG Series (Third Generation -Voice Gateway Models): INI-VGC: (Command Center Voice Gateway (UTP only) INI-VGE: Command Center Classic Voice Gatewa (UTP onl ) INI-VGX: Transponder Voice Gateway (UTP only) Accessories: FML-E3: Multi -Mode Fiber -Optic Module FSL-E3: Single -Mode Fiber -Optic Module INI-VG Series Legacy Models: 1100-1321: IN1-VGC-FO (Command Center Voice Gateway -fiber-optic module) 1100-1322: INI-VGC-UTP (Command Center Voice Gateway -unshielded twisted -pair only) 1100-1325: IN1-VGE-FO (Classic Bulk Voice Gateway -fiber-optic module) 1100-1326: IN1-VGE-UTP (Classic Bulk Voice Gateway -unshielded twisted -pair only) 1100-1323: INI-VGX-FO (Voice Transponder Gateway -fiber-optic module) 1100-1324: IN1-VGX-UTP (Voice Transponder Gateway -unshielded twisted -pair only) STANDARDS The INI-VG Series is designed to comply with the following standards: UL Standards: UL 864, loth Edition UL 2572, 2nd Edition for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 864,10th Edition S1949 2572, 2nd Edition for Mass Notification FM Approved: 30006578 M EA Approved FDNY: COA#:-6077 CSFM: 7165-1703:125 City of Chicago Approved: Class 1 Class 2 High Rise City of Denver Approved ISO 9001 Certification 9020-0648 1 K 1 06/20 ©2020 Honeywell International Inc. Honeywell ��:9.F41i:53 LCD Touchscreen Annunciator Display The LCD-SLP is a touchscreen interface used with the S3 Series and E3 Series' panels. GENERAL The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series and E3 Series° Systems. The LCD-SLP provides an easy -to -use, intuitive interface for the operator's control. The 4.3" (10.92 cm) color touchscreen display shows the following: • System Status • Event Details Service Modes The following identify the LED Indicators that display on the panel. • AC (green) • Fire Alarm (red) • Hazard (blue) • Supervisory (yellow) • Trouble (yellow) • Silenced (yellow) The five fully -programmable front panel switch/LED combinations provide a direct access to perform the following tasks: • Device Bypass • Lamp Test Enable/Disable Groups or Devices The display features the following physical switches: • Menu • System Reset Drift Walk Test • Five Programmable Switches INSTALLATION The LCD-SLP panel's adaptable design allows itto be mounted in a variety of S3 Series, E31 Series or Retrofit cabinet installations. For additional information, refer to the E3 Series Cabinets Data Sheet, P/N:9020-0649. • S3 Series Cabinets: — SLP-BB basic system enclosure — S3BB-BB/S3BB-RB system enclosure • E3 Series° Cabinets: — AA size cabinet (E3BB-BAA, E3BB-RAA) — A2 size cabinet (E3BB-BA2, E3BB-RA2) — A size flush cabinet (E3BB-FLUSH-LCD) — B-Slim cabinet (E3BB-RBSLIM) — B size cabinet (E3BB-BB, E3BB-RB) — C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) — D size cabinet (E3BB-BD/INCC, E3BB-RD/INCC) • Retrofit Cabinets: — 600-RETROFIT — 7200-B-RETROFIT — 7200-C-RETROFIT ORDERING INFORMATION 1-CID-SLIP: LCD Touchscreen display unit E31313-13A2: Remote enclosure with inner door, black, one LCD slot E3BB-RA2: Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD: Remote flush mounting enclosure, black, LCD slot FEATURES AND BENEFITS • Listed perANSI/UL° Standard 864, loth Edition • UL Listed and FM approved for Pre- Action/Deluge and Agent Releasing • Provides 4.3" (10.92 cm) color touch - screen display of System Events • Includes five custom function buttons with LEDs for direct access to system controls. • Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases • Both the E3 Series (ILI-MB-E3/ILI95- MB-E3) and the S3 Series (SLP) support up to 15 LCD-SLP displays via the RS- 485 serial interface • Offers the following installation options: — Locally mounted in the E3 Series and S3 Series panels: — Remotely mounted in the E3 Series, A2 cabinet — LCD Flush enclosure WOMEN 0 0 LCD-SLP • Displays the following six LED indica- tors: — AC Power —Alarm — Hazard — NAC Silence — Supervisory — Trouble Honeywell LCD-SLP TECHNICAL SPECIFICATIONS SYSTEMS Operating Voltage: 24VDC FWR Operating Current: 0.030 amp Alarm Current: 0.065 amp Operating Temperature: 320to1200 F (00 to 49' C) Relative Humidity: 0 to 93%,non-condensing at 901 F (321 C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 491C/32 — 120°F and at a relative humidity 93% ± 2% RH (non - condensing) at 32°C±20C (900F±309. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 270C/60 — 80OF. STANDARDS Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com The LCD-SLP is designed to comply with the following standard: UL Standard: UL 864, loth Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 UL 864,10th Edition FM Approved MEAFDNY: COA#6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification 9021-60782 1 G 1 06/20 ©2020 Honeywell International Inc. Honeywell Honeywell I Addressable Devices QGamewell �^gin MS-7 Series Manual Fire Alarm Pull Stations General The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pullstationscomply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pullstations include a key lock/resetwhich is keyed alike with the Gamewell-FCI fire alarm control panels and other man uaIfire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog MS-7 Series addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi - flush mounting • Shock and vibration resistant • Conventional stations Both single and double suitable for use with action pull stations any UL Listed control available panel • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. Itfeatures a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for usewith the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-71_013 station must be mounted on a Model SB-1/0 backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi -flush mounted on a standard double -gang, or4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. 7 NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action station MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual -action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-1/0 - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi -flush mount, plastic NY -PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications SYSTEMS Material: Lexan' Contact Ratings: 0.25 amps. @ 30 VAC/VDC (resistive) Dimensions: 5 5/8" H x 41/4" W x 1 1/4" D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 32° to 120' F (Coto 49' C) (MS-7LOB): -30'to 150' F (-35° to 66' C) Relative Humidity: (MS-7AF, MS-7ASF):10 to 93% (non -condensing) (MS-7LOB): 85%± 5% C 86' ± 3.6° (30' ± 2° C) Alarm Current:.0030 amp. 0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF):.00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 -120°F and at a relative humidity 93%± 2% RH (noncondensing) at 32°C ± 2°C (901F± 31F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The MS-7 Series is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. UL:S2465 FM:3023594 M EA FDNY: 67-02-E Vol. VI I CSFM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification 9020-0616 1 F 1 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gameweL[- fci.com/en-US/ documentation/Pages/ Listings.aspx LEXAN° is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velociti® and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell I Analog and Networking Systems QGamewell PM-9 120 VAC Power Supply General The Gamewell-FCI, PM-9 Power Supply is a 120 VAC, 60 Hz switching power supply that provides 9 amperes of filtered and regulated 24 VDC (nominal). It provides the power to all of the E3 Series components. It is a component of the following systems: • E3 Series° Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System The PM-9 has an internal battery charging circuit capable of maintaining up to 55 A/H batteries. Installation Typically, the PM-9 Module can be mounted in the following E3 Series cabinets: • Cabinet B backbox • Cabinet C, INX-E3 sub -assembly plate • Cabinet C, INCC-E3 sub -assembly plate • Cabinet D, E3-INX-D Plate • Cabinet D, E3-ILI-D Plate • Retrofit Kits For information on the installation of the PM-9, refer to the following documents: • E3 Series Expandable Emergency Evacuation Manual, P/N: LS10080-000GF-E • PM-9 Installation Instructions, P/N: 9000-0548 • Mass Notification System Manual, P/N:LS10013-000GF-E Ordering Information PM-9: Power supply and battery charger, 120 VAC 29229:AC Line Filter Kit FEATURES & BENEFITS fT� • Listed under UL° Includes 9 ampere, Provides 1 ampere Offers energy and Contains an integral Standard 864, 9th filtered, regulated battery charging space saving switching battery charger Edition power supply current technology capable of recharging up to 55 AH batteries. • Listed under UL (Batteries not Standard UL2572 for furnished) Mass Notification PM-9 Technical Specifications SYSTEM STANDARDS For a complete listing of all compliance approvals and Input Voltage: 120 VAC 60 Hz @ 3.5 A. max. The PM-9 is designed to comply with the following certifications, please visit: Output Voltage: 24 VDC (nominal) FWR standards: http://www.gamewell- Output Current: 9 amperes UL Standards: UL 864 9th Edition fci.com/en-US/ Output Current: 1 ampere batter charging p p Y 9 9 UL 2572 for Mass Notification documentation/Pages/ Listings.aspx current AGENCY LISTINGS AND APPROVALS Alarm Current: 0.050 amp E3Series®and Gamewell-FCI° OperatingTemperature: 32° to 120° F (0° to 49° C) p These listings and approvals apply to the modules are registered trademarks of specified in this document. In some cases, certain Honeywell International Inc. Relative Humidity: 0 to 93%(non-condensing) at modules or applications may not be listed by certain o 90° F (32° C) approval agencies, or listing may be in process. Consult UL Is a registered trademark of Underwriter's Laboratories Dimensions: 101/2" W x 5" H x 2" D the factory for the latest listing status. Inc. (27 x 13 x 5 cm) UL Listed: S1869, Vol.14 This document is not intended TEMPERATURE AND HUMIDITY RANGES UL Listed: S1949, Vol. 19 to be used for installation This system meets NFPA requirements for operation at 0 FM Approved: 3017416 purposes. We try to keep our — 491C/32 —120°F and at a relative humidity 93%± 2% MEA FDNY: COA 6077 product information up-to- (noncondensin ) at 32°C ± 2°C (90°F± 3°F). g CSFM: 7165-1703:0125 and accurate. We cannot dateRH coverall specific applications However, the useful life of the system's standby batteries City of Chicago Approved: Class 1, Class 2,High Rise or anticipate all requirements. and the electronic components may be adversely affected City of Denver Approved All specifications are subjectto by extreme temperature ranges and humidity. Therefore, ISO 9001 Certification change without notice. it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. For more information Learn more about Gamewell-FCI's PM-9 and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 www.ho eywe @2017Hon 4 09e17 Honeywell www.honeywell.com ©2017 Honeywell International Inc. Honeywell I Analog and Networking Systems QGamewell �� RPT-E3 Network Repeater General The ARC NET Repeater Module (RPT-E3) is an optional component of the E3 Series° and S3 Series fire alarm control panels. It allows the following remote E3 Series and S3 Series sub -assemblies to connect to the Broadband network from remote locations: • ILI-MB-E3/ILI95-E3Series • S3 Series, SLP (Smart Loop Panel -Main Board) • ANX-SR/ANX-MR-UTP/ANX-MR-FO • NGA The RPT-E3 is a standard sub -assembly with network connections using unshielded, twisted -pair, copper wire. The following optional fiber-optic network connections using add -on modules are available. • FML-E3 multi -mode fiber module (optional) • FSL-E3 single -mode fiber module (optional) In addition, you can use the RPT-E3 to connect remotely -mounted NGA modules to the network. Installation The RPT-E3 is adaptable for an installation in the standard E3 Series and S3 Series cabinets. Typically,the RPT-E3 module is mounted on standoffs on the top of the right side of the ILI-MB-E3/ILI95-MB-E3/ANX modules and SLP motherboard. For instructions on the installation of the RPT-E3, refer to the following documents: • E3 Series° UL Listing Document, P/N: LS10080-051GF-E • S3 Series UL Listing Document, P/N:LS10005-051GF-E • RPT-E3-UTP Installation Instructions, P/N: 9000-0580 • FML-E3/FSL-E3 Installation Instructions. P/N:LS10046-000GF-E Ordering Information RPT-E3-UTP: Network Repeater, unshielded, twisted -pair FML-E3: Multi -mode fiber-optic module for RPT-E3-UTP (one channel) FSL-E3: Single -mode fiber-optic module for RPT-E3-UTP (one channel) FEATURES & BENEFITS • Listed under UL° Standard 864, 9th Edition • Offers the 625K baud ARCNET Repeater • Provides the capability for networked E3 Series and S3 Series sub- assemblies to connect in Styles 4 or 7 configurations • Connects to the network via the standard unshielded, twisted -pair copper wi re • Includes add -on fiber- optic modules that allow the network connection through single or multi -mode fiber-optic cables • Use the RPT-E3 to connect remotely - mounted NGAmodules to the network RPT-E3 Technical Specifications SYSTEM Operating Voltage: 24VDC FWR Operating Current: 0.016 amp Alarm Current: 0.017 amp Operating Temperature: 321 to 1201 F (01 to 490 C) Relative Humidity: 0 to 93%, non -condensing at 900 F (320 C) Wiring Specifications: Copper Wire: 16 to 18 AWG twisted -pair, unshielded. Up to 3,000 ft. (914.4 m) between each node. Fiber -Optic Cable (FML-E3 only): Up to 200 microns optimized for 62.5/125 microns. Up to 8 dB loss between nodes. Fiber -Optic Cable (FSL-E3 only): Optimized for 9/125 micrometer cable @ 1310 nm. Up to 30dB loss between nodes. For more information Learn more about Gamewell-FCI's RPT-E3 and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The RPT-E3 is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved: 3025415 MEA Approved, Fire Dept. of New York: COA# 6077 CSFM: 7165-1703-0125 City of Chicago: Class 1, Class 2 and High Rise City of Denver ISO 9001 Certification 9020-0609 1 0 1 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gameweL[- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI° are registered trademarks of Honeywell International Inc. UL° is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell I Notification Appliances QGamewell �^gin LSeries, Indoor Ceiling Strobes and Dual Speakers Indoor Output Speaker Strobes and Dual Speakers for Ceiling Applications) General The L-Series indoor selectable -outputs pea kerstrobes and dual -voltage evacuation _ Speakers offer a modern, aesthetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in ceiling applications and its flexible design enables the Installer to easily perform the following: ' • Pre -wire mounting plates • Dressthewires Confirm wiring continuity before the Installer plugs -in the speakers. In addition, this - product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. Ceiling Speaker Strobes • The rotary switches are set to the selected voltage and power settings. • The 7 field -selectable candela settings are configured for wall speaker strobes. • The low total harmonic distortion of the SP speaker offers both high-fidelity and high -volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy to installthe L-Series speakers or speaker strobe, do the following: 1. Attach a universal mounting plate to a 4 x 4 x 21/8 inch backbox. Flush - mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mounting plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch temporarily holds the device in place until you secure the device with a captured mounting screw. FEATURES & BENEFITS • Includes a plug-in feature and protective cover to reduce ground fa u Its • Contains a universal mounting plate with an on -board shorting spring that is used to test the wiring continuity before an installation • Field -selectable • Uses an automatic candela settings on selection of 12- or 24- ceiling units: volt operation at 15 - 15 and 30 candela - 30 • Provides a rotary switch that simplifies - 75 the field selection of - 95 speaker voltage (25) and 70.7 VRMs) and the - 115 following power - 150 settings: • No extension ring - 177 required - 1/4 watt - 1/2 watt - 1 watt - 2 watts • Offers speakers with both high-fidelity and high -volume sound output • Compatible with the System Sensor synchronization protocol • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products • Designed with a tamper -resistant construction • Built with an updated modern design L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plate shall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, the L-Series speaker strobes, when used with the Sync -Circuit. Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When these devices are used with the Sync -Circuit Module, either of the following may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 321 Fand 120OFfrom a regulated DC, or full -wave rectified, unfiltered power supply. Speakerstrobes shall have the following field -selectable candela settings: • 15 • 30 • 75 95 • 115 • 150 • 177 Speaker The speaker shall be an L-Series model dual - voltage transformer speaker capable of operating at 25.0 or 70.7 nominalVRMs. It should be listed to UL Standard 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 320F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model listed to UL Standard 1480 and UL Standard 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have powertaps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a Sync -Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mountto a 411/16 x 411/16 x 2 1/8-inch back box. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize allthe zones they control. The module shall not operate on a coded power supply. UL Current Draw Data Table 1 lists the UL maximum strobe current draw. 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA ill 142 95 NA 134 164 115 NA 158 191 150 INA 1189 1228 177 INA 1226 1264 Table 1 UL Max. Strobe Current Draw (mA RMS) Table 2 lists the ceiling mount speaker sound outputs. Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @010 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 188 188 Table 2 Ceiling Speaker Sound Outputs Table 3 lists the ceiling -mount speaker strobe sound outputs. Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 3 Ceiling -Mount Speaker Strobe Sound Output Dimensions Figure 1 shows the speaker dimensions. Figure 1 Speaker Dimensions Figure 2 shows the speaker dimensions. aver Figure 2 Speaker Dimensions Surface Mounting zar Figure 3 illustrates the ceiling -mount speaker and speaker strobes with the SBBCR/SBBCWL surface mount backbox. Figure 3 Ceiling -Mount Speaker and Speaker Strobe with SBBCRL/SBBCWL Surface Mount Backbox L-Series Ordering Information SpectrAlert Speakers and Strobes: Ceiling Mount: SPCWL: White Speaker only SPCRL: Red Speaker only SPSCWL: White Speaker Strobe SPSCRL: Red Speaker Strobe SPSCWL-P: Plain, Speaker Strobe SPSCWL-SP: Fuego, Speaker Strobe SPSCWL-CLR-ALERT : Alert, Speaker Strobe,Clear Lens Accessories: SBBCWL: White, Universal Ceiling Surface Mount Back Box SBBCRL: Red, Universal Ceiling Surface Mount Back Box TRC-2W: White, Universal Ceiling Trim Ring TRC-2: Red, Universal Ceiling Trim Ring L Series, Indoor Ceiling Strobes and Dual Speakers Technical Specifications SYSTEM Physical Specifications: Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non -condensing Dimensions,Ceiling- Mount: Diameter Depth SPCSpeaker 6.8 in,173 mm 1.0 in,25 mm With Surface Mount BacKbox 6.9 in,176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in,173 mm 2.8 in, 73 mm With Surface Mount Backbox 6.9 in,176 mm 5.37 in,136 mm Electrical/Operating Specifications: Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50 VDC Strobe Flash Rate:1 flash per second Nominal Voltage (strobes): Regulated 12 VDC or Regulated 24VDC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync): 8 to 17.5 V (12 V nominal) or 16 to 33 V(24V nominal) Operating Voltage with M DL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range: Frequency Range: 400 to 4,000 Hz Power: 1/4,1/2, 1, 2 watts For more information Learn more about Gamewell-FCI's L Series, Indoor Ceiling Strobes and Dual Speakers and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The L-Series, Indoor Ceiling Strobes and Horn Strobes are designed to complywith the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. UL: S5512, S4011 CSFM: 7320-1653:0505 ISO 9001 Certification 9021-60930 1 C 1 03/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gameweL[- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI° are registered trademarks of Honeywell International Inc. UL° is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell FNP SERIES - NP18-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES • Superb recovery from deep discharge. • Electrolyte suspension system. • Gas Recombination. • Multipurpose: Float or Cyclic use. • Usable in any orientation. • Superior energy density. • Lead calcium grids for extended life. • Manufactured World wide. • Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals Bolt fastened terminal E 12 : 0,2 2 : 0,1 s.s INCH = MM 472 12.00 .453 11.50 N 433 11.00 --- .216 5.50 .079 2.00 Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. Layout 2 O O General Specifications Nominal Capacity (Ah) NP18-12 20hr to 1.75vpc 30°C 17.2 10hr to 1.75vpc 20°C 16 5hr to 1.70vpc 20°C 14.5 1 hr to 1.60vpc 20oC 10.3 Voltage 12 Energy Density (wh.L.20hr) 94 Specific Energy (wh.kg.20hr) 38 Int. Resistance (m.Ohms) 11 Maximum discharge (A) 112 Short Circuit current (A) 500 Dimensions (mm) Length 180 Width 76 Height overall 167 Weight (Kg) 6.2 Terminal E Layout 2 Terminal Torque Nm - NP SERIES - NP18-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter -plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME , Bdk Chug. S1wdby Che , OJ 50 17 Ti— Ti— W 025 25 B w' Ch m. Vd.— FB a 1s 2 u o2 =g +m § Cnerga v.R., ,Y e 0.15 $ 75 F p 13 0 0.1 50 I Cu"M Tro P.'. c u i=0.07C Amps 12 0M 25 „ -- Chugs Cumn, 0 0 0 FLOAT SERVICE LIFE NP RANGE T AH%) TESTING CONDITIONS'. FLOATING VOLTAGE. 2275VPC C ( AMBIENT TEMPERATURE. 20•C(611FTO 72-9 120 100 O 80 19 =J QO W �_ 20 Q 0- 0 1 2 3 4 _ 5.5 1 IFF (YFARS) )111r( YUASA Yuasa Battery Inc. 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat. No NP7-12 January 08 Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15°C to 50°C Discharge — 20°C to 60°C Storage — 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS %) IDD 0•C(3219 75 U `� 50 zo•c � a 40°C (109• (BB•F) ¢ 25 C 3 6 g 12 15 16 STORAGE TIME (MONTHS) FLOAT CHARGE CHARACTERISTICS g� gU U�pm 025CA- 2.275VPC CONSTANT VOLTAGE CHARGING (%) (. A) M AT 20•C (66•F) o �0 M 120 025 750 I CHARGED VOLUME_ - - - 15.0 100 02D ---_----____ 7A0 - CHARGE VOLTAGE 14.0 IIr7 BB 0.15 SO 650 —AFTER 1W%DISCHARGE 13.0 0.10 - - - AFTER 50% DISCHARGE BAO 12.0 6 60 -_ CHARGING CURRENT 0 o z a e e +o +2 a 16 16 zo CHARGING TIME (HOURS) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS. DISCHARGE CURRENT: 0., 7C Amp. (F.V 1.7V/CELL CHARGING CURRENT 0.09C Amp CHARGING VOLUME: 125%OF DISCHARGED CAPACITY (AH%) AMBIENT TEMPERATURE: 20°C TO 25•C(6WF TO 7 F) -7� 1 yU 0 100% 501 30%DEPT LWO, DOD DOD OF DISC GE 6 0 1pp y0 toao 1-. 4. NUMBER OF CYCLES Distributed by