REVIEWED BLD2023-1421+Structural_Calculations+11.8.2023_9.24.49_AM+3888199RECEIVED Nov 09 2023 SOUND STRUCTURAL SOLUTIONS CITY OF EDMONDS E N G I N E E R S DEVELOPMENT SERVICES DEPARTMENT March 13, 2023 BLD2023-1421 To: Rob Michel, Michel Design From: Evan Underbrink, PE, SE Re: 7824 175th St SW Geogrid Slope Stabilization SSS# s2009O29 The geotechnical engineer has designed a system to stabilize the slope and keystone block wall behind the house. The top layer of geogrid is to be anchored to the existing foundation wall using a pressure treated 2x6 anchored with 1/2" x 5" long Simpson Titen HD screw anchors at 30". Please see the attached detail for reference. If you have any questions or require additional information, please call. Attached: Patio Modular Block Wall Detail (from Geotech included for reference) Detail GGA Supporting calculations ALL WORK SUBJECT ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ................................. : The following documentation shall be available on ' TO FIELD = site for the building inspector: INSPECTION FOR ■ - CODE COMPLIANCE = ❑ COE APPROVED ARCHITECTURAL PLAN SET : ❑ COE APPROVED STRUCTURAL PLAN SET ; APPROVED PLANS MUST BE : ❑X COE REVIEWED CALCULATION PACKET ' ON JOB SITE : ❑ ENERGY CREDIT WORKSHEET ❑ SITE PLAN ; ❑ CIVIL PLAN ' ❑X Sheets W1,P1, and Al � ; ❑ ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ 24113 56t" Ave W - Mountlake Terrace, WA 98043 - Ph: 425-778-1023 - www.ssseng.com GEOGRID R GEOTECH GGA GEOGRID ANCHORAGE N.T.S. EXISTING SLAB ON GRADE N GEOGRID WRAPPED AROUND PRESSURE TREATED 2x6 LEDGERS AND ANCHORED INTO FOUNDATION / 0 x 5 #TITEN-HD SCREW ANCHORS @ 30" oc & AT EA END / OF 2x6 LEDGERS (3%" MINIMUM EMBEDMENT INTO \/ EXISTING FOUNDATION) , \� EXISTING HOUSE FOUNDATION WALL i Project Title: Engineer: Project ID: Project Descr: Wood Beam Project File: s2009O29.ec6 DESCRIPTION: Wood Ledger CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Fb + 850 psi E: Modulus of Elasticity Load Combination: ASCE 7-16 Fb - 850 psi Ebend- xx 1300 ksi Fc - Prll 1300 psi Eminbend - xx 470ksi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade No.2 Fv 150 psi Ft 525 psi Density 26.84 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 2x6 Span = 2.50 ft Applied Loads Beam self weight NOT internally calculated and added Uniform Load : E = 0.50 , Tributary Width = 1.0 ft, (Geogrid Load) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. Design OK Maximum Bending Stress Ratio = 0.97a 1 Maximum Shear Stress Ratio = 0.414 Section used for this span 2x6 Section used for this span 2x6 fb: Actual = 1,590.89 psi fv: Actual = 79.55 psi Fb: Allowable = 1,626.56 psi Fv: Allowable = 192.00 psi Load Combination E Only" 0.70 Load Combination E Only" 0.70 Location of maximum on span = 1.254ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.231 in Ratio = 129 > 1 Span: 1 : E Only Max Upward Transient Deflection -0.231 in Ratio = 129 -1 Span: 1 : E Only* -1.0 Max Downward Total Deflection 0.162 in Ratio = 185 > 1 Span: 1 : E Only * 0.70 Max Upward Total Deflection -0.162 in Ratio = 185 > 1 Span: 1 : E Only * -0.70 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear a ues Segment Length Span # M V Cd CFN C i Cr Cm C t CL M fb F'b V fv F'v 0.00 0.00 0.00 0.00 Length = 2.50 ft 1 0.90 1.300 0.80 1.00 1.00 1.00 1.00 914.94 0.00 0.00 108.00 E Only' 0.70 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 2.50 ft 1 0.978 0.414 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.27 1,590.89 1626.56 0.44 79.55 192.00 E Only' -0.70 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 2.50 ft 1 0.978 0.414 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.27 1,590.89 1626.56 0.44 79.55 192.00 E Only" 0.5250 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 2.50 ft 1 0.734 0.311 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.21 1,193.17 1626.56 0.33 59.66 192.00 E Only"-0.5250 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 2.50 ft 1 0.734 0.311 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.21 1,193.17 1626.56 0.33 59.66 192.00 Wood Beam LIC# : KW-06017385, Build:20.22.2.2 DESCRIPTION: Wood Ledger Overall Maximum Deflections Load Combination Span Vertical Reactions Load Combination Project Title: Engineer: Project ID: Project Descr: Project File: s2009O29.ec6 Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span 1 0.0000 0.000 E Only * -1.0-0.2312 1.254 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Overall MlNimum -0.625 -0.625 E Only* 0.70 0.438 0.438 E Only* -0.70 -0.438 -0.438 E Only * 0.5250 0.328 0.328 E Only *-0.5250 -0.328 -0.328 E Only 0.625 0.625 E Only* -1.0 -0.625 -0.625 E-7i►vi�-Z•�c■ Anchor DesignerTM Software Version 3.1.2301.3 1.Project information Customer company: Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-19 Units: Imperial units Anchor Information: Anchor type: Concrete screw Material: Carbon Steel Diameter (inch): 0.500 Nominal Embedment depth (inch): 3.500 Effective Embedment depth, hef (inch): 2.560 Code report: ICC-ES ESR-2713 Anchor category: 1 Anchor ductility: No hmfn (inch): 5.42 cap (inch): 3.88 Cmw (inch): 1.75 Smin (inch): 3.00 Recommended Anchor Anchor Name: Titen HD® - 1/2" 0 Titen HD, hnom:3.5" (89mm) Code Report: ICC-ES ESR-2713 Company: Date: 1 /30/2023 Engineer: Page: 1/5 Project: Address: Phone: E-mail: Project description: Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 6.00 State: Cracked Compressive strength, F� (psi): 2500 Wc,v: 1.0 Reinforcement condition: Supplementary reinforcement not present Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: Yes Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com l+'71►��11+7•J►■ Anchor Designer TM Software Version 3.1.2301.3 QD Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: Not applicable Ductility section for tension: 17.10.5.2 not applicable Ductility section for shear: 17.10.6.2 not applicable Do factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: Yes Strength level loads: Nua [lb]: 1500 Wax [lb]: 0 Way [lb]: 0 <Figure 1> x M Company: Date: 1 /30/2023 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z 15 OA Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-7i►vi�-Z•�c■ Anchor DesignerTM Software Version 3.1.2301.3 <Figure 2> 3.50 Company: Date: 1 /30/2023 Engineer: Page: 3/5 Project: Address: Phone: E-mail: .. 3 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-7i►vi�-Z•�c■ Anchor DesignerTM Software Version 3.1.2301.3 Company: Date: 1 /30/2023 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua (Ib) Vu (Ib) Way (Ib) �(Vuax)2+(Vuay)2 (Ib) 1 1500.0 0.0 0.0 0.0 Sum 1500.0 0.0 0.0 0.0 Maximum concrete compression strain (%o): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (Ib): 1500 Resultant compression force (Ib): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.6.1) Nsa (Ib) 0 ^a (Ib) 20130 0.65 13085 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) Nb = kcAia f'chofl s (Eq. 17.6.2.2.1) kc A. f� (psi) hof (in) Nb (Ib) 17.0 1.00 2500 2.560 3482 0.75^b = 0.750 (ANc/ANco)Y%d,NY%,NY%p,NNb (Sec. 17.5.1.2 & Eq. 17.6.2.1a) A (in') ANco (in' ca,.m (in) %d,N Pc,N :op,N Nb (Ib) 0 0.750Ncb (lb) 56.37 58.98 3.50 0.973 1.00 1.000 3482 0.65 1579 11. Results Interaction of Tensile and Shear Forces (Sec. 17.8) Tension Factored Load, Naa (lb) Design Strength, 0Nn (lb) Ratio Status Steel 1500 13085 0.11 Pass Concrete breakout 1500 1579 0.95 Pass (Governs) 112"0 Titen HD, hnom:3.5" (89mm) meets the selected design criteria. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-7i►vi�-Z•�c■ Anchor DesignerTM Software Version 3.1.2301.3 Company: Date: 1 /30/2023 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 12. Warnings - Per designer input, the tensile component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor tensile force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.10.5.2 for tension need not be satisfied — designer to verify. - Per designer input, the shear component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor shear force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.10.6.2 for shear need not be satisfied — designer to verify. - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com