Loading...
RESUB 1-BLD2024-1018-FOR REFERENCE-Civil_Plan+9.6.2024_1.40.07_PM+4485346)SED �i8 y I -P 12.(11 1. 0' Approved �\ D F M ckrts gust \ South County Fire \ Date: 05/14/2024 I 1 I -FOUND REBAR W/CAP STD "22969" 0.1 '(N) OF r'r'E)^' I I I I I I I I I I � I i I I I -PROPOSED BLOCK WALL 05-15-2024 RESUB 4 PLAN REVIEW NOTES: APPROVED WITH CONDITION NOTED ON SHEET C3.2. DFM BURT APPROVED BY PLANNING NE 114, SEC. 13, T. 27 N., R.03 E., W.M. May 132024 SNOHOMISH COUNTY, WASHINGTON ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE SCALE: 1 " = 10' 10 5 0 10 20 THE CERTIFIED EROSION AND SEDIMENTATION CONTROL LEAD (CESCL) FOR THIS PROJECT SITE IS BRLW IG4LAB PHONE NO. 425-303-9363. 1. PROVIDE BLUE STREET REFLECTOR(S) ON THE HYDRANT SIDE OF CENTERLINE TO INDICATE HYDRANT LOCATIONS. / NOTE r 1. THE CITY'S PUBLIC WORKS OPERATIONS AND MAINTENANCE DEPARTMENT TO FABRICATE FIRE/AID ADDRESS SIGN AND/OR STREET ADDRESS SIGN. THE CONTRACTOR/OWNER SHALL CONTACT THE ENGINEERING DIVISION BY EMAIL AT ACCESS & UTILITY ENGINEERINGPERMITS@EDMONDSWA.GOV TWO WEEKS IN ADVANCE OF THE REQUESTED SIGN FABRICATION. A SIGN FABRICATION FEE WILL BE EASEMENT COLLECTED PRIOR TO PERMIT ISSUANCE. FIRE/AID ADDRESS SIGNS ARE $100 PER SIGN. STREET ADDRESS SIGNS ARE $200 PER SIGN. AFN-1926981 2. EACH HOME SHALL BE EQUIPPED WITH A 13D SPRINKLER SYSTEM. J. SQUARE FOOTAGES SHOWN IN THE IMPERVIOUS AREAS TABLE ARE THE I MAXIMUM IMPERVIOUS AREAS ALLOTED FOR EACH LOT. ROAD IMPERVIOUS AREA WILL FLOW TO THE DETENTION SYSTEM ALONG WITH v I IMPERVIOUS AREAS FROM EACH LOT. %...................... SPECIAL INSPECTIONS REQUIRED 1 19120 94TH AVE BY ENGINEERING DIVISION 1 1 (REFER TO SI AGREEMENT): 0043460000610 r vvlv) REBAR I - UTILITY PIPE ANCHORS j W/CAP STAMPED - STABILIZATION OF SLOPE I_ "22969" 0.2'(N) 1 - DETENTION VAULT I OF CORNER L--------------------- SEE SHEET C3.0 \\ I I FOR THE \ I EASEMENT LIMITS. 1 SS 1 N ------FOUND REBAR W/CAP I-T STAMPED "22969" 0.2'(N) & 0.1 '(E) OF CORNEF N I \ \ PROPOSED SEWER RECORDED PRIOR TO FINAL INS[ \ IN CONJUNCTION W/AS-BUILTS 1 \ 1 \ 00 1 1 I C " 19 1, \\ / I I � � I I 14,110 SF \\\ /C,�, \ \ \ 0043�600006106 ` :�InF K 11 Q 1 'l( 1 I (TO BE ABANDONED AND NEW O / G C-' CONNECTION TO BE PROVIDED TO LOT D) l -'22//`l / P P- -o •1 , � I 1 Know what's below. Call before you dig. UTILITY CONFLICT NOTE:• CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. SSCO \ RIM:256.29 \ 248.29 30+00 DGE OF EASEMENT 1 I ACCESS & OTILITI EASEMENT AFN-19269,81 \ BM APPROVED PLANS MUST BE ON JOB SITE LEGEND 51,W BL D 2 0 2 4- 0 9 2 6 + EXISTING MONUMENT (AS SHOWN) C>Oa SECTION 1/4 CORNER NOT FOUND` 3 SECTION CORNER NOT FOUND COMPLIES WITH APPLICABLE CITY STORMWATER CODE • FOUND REBAR/CAP OR I.P. (IRON PIPE) Y P 90T s, ]W (C) CALCULATED (P) PLAT (M) MEASURED SITE ' TBR TO BE REMOVED R.O.W. RIGHT-OF-WAY FOUND CASED CONC. MON. _ P.0.8. POINT OF BEGINNING FOUND CASED CONC. MON. AT THE INTERSECTION w/2" BRASS DISK & "X". r CENTERLINE OF 190TH PL. S.W. & 94TH AVE. W. DOWN 0.5'. VISITED 2-27-20. CLF CHAIN LINK FENCE ELEV. = 253.68' , , 2.5'(S) & 0.3'(W) OF CALCULATED WDF WOOD FENCE N POSITION FOP WATER SURFACE _`•"- • PER CPS OBSERVATIONS / I - / I City Of Edmonds Building Department ........................................ Work CONSTRUCTION OF DRIVE AISLE, FIRE LANE, UTILITIES Address..................................19128 94TH AVE W �.�.�.�.�.�.�.�.�.� Owner LANDSVERK QUALITY HOMES INC , .............. Approved Date 05/13/2024 .............3�`�� Building Official Erl r/:C4wfPAY:::::................................ V� / Permit Number .�..............:::::::::BLDZOZZ-O9Z6...............?7; \ 158.00'40 N t 1 Wf4� 19204 DRI EWAY a a \ \ T EXG SIDE SEWER TO 19210 TO REPLACED SIDE SEWER F 31 / 8 EDGE F PAVEMENT W E r , Applicant shall repair/replace all BOW BACK OF WALK VICINITY MAP damage to utilities or frontage 0 CB STORM DRAIN CATCH BASIN (CB) S SCALE: 1 "=2000' improvements in City right-of-way per city standards that is caused or O STORM DRAIN MANHOLE (SDMH) occurs during the permitted project. SD ENGINEER/CONTACT SURVEYOR O SS SANITARY SEWER MANHOLE (SSMH) INSIGHT ENGINEERING COMPANY PACIFIC COAST SURVEYS, INC. 000 SANITARY SEWER CLEAN OUT (CO) P.O. BOX 1478 P.O. BOX 13619 NOTE EVERETT WA 98206 MILLCREEK, WA 98082 A SEPARATE RIGHT-OF-WAY CONSTRUCTION PERMIT IS �P POWER POLE • P.E. CONTACT. DARREN J. RIDDLE, PLS CONTACT.BRIAN R. KALAB, PH: (425) 303-9363 PH: (425) 508-4951 REQUIRED FOR ALL THE WORK WITHIN THE CITY RIGHT-OF-WAY. EMAIL: INFO®INSIGHTENGINEERING.NET FAX. • (425) 357-3577 -0-cP GUY POLE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST ON SITE FOR ANY WORK WITHIN ❑ WM WATER METER OWNER/APPLICANT TREE PROTECTION FENCE PURSUANT TO ECDC 23.10.070.C.3 >< WATER VALVE LANDSVERK QUAD Y HOMES, INC. WV 24113 56TH AVE W. MAILBOX MOUNTLAKE TERRACE, WA 98043 MB II \ 'C� UTILITY POLE ANCHOR FIRE HYDRANT (2 NOZZLE) LEGAL DESCRIPTION I I TYPE I NGPA SIGN PARCEL NO. 00434600006201 THE WEST 112.70 FEET OF TRACT 62 AND THE EAST 50.00 FEET OF TRACTS 80 AND 81, ALL IN EDMONDS SEA VIEW TRACTS, I a PROPOSED WATER ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 3 OF PROPOSED SANITARY SEWER PLATS, PAGE 76, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. PROPOSED STORM DRAINAGE (ALSO KNOWN AS PARCEL B, CITY OF EDMONDS LOT LINE ADJUSTMENT RECORDED UNDER RECORDING NO. 8311180116) ° PROPERTY LINE 6'� 3 I X X EXISTING FENCE LINE PARCEL N0. 00434600006102 \ / THE NORTH 88 FEET OF THE WEST 137 FEET OF TRACT 61, F I I / EDGE OF PAVEMENT EDMONDS SEA VIEW TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 3 OF PLATS, PAGE 76, RECORDS OF a \ — - XXX EXISTING CONTOURS SNOHOMISH COUNTY, WASHINGTON. PROPOSED CONTOURS TOGETHER WITH AN EASEMENT FOR INGRESS, EGRESS, AND UTILITIES PRE-EXISTING DRAINAGE PATTERN AS RECORDED UNDER AUDITOR'S FILE NO'S. 1926981 AND 1926982, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, AND, 40Z STEEP SLOPE AREA SUBJECT TO EASEMENTS RESTRICTIONS AND RESERVATIONS OF / — I (JO% NATIVE VEGETATION RETENTION RECORD. / I W PROPOSED) P UTILITIES (POWER, CABLE, TELEPHONE) (ALSO KNOWN AS PARCEL 1, CITY OF EDMONDS SHORT SUBDIVISION FOUND REBAR W/CAP I �T TRANSFORMER BOX #S-52-66, RECORDED (UNDER RECORDING NO. 8710230442) I SANITARY SEWER CLEAN OUT PARCEL NO. 00434600006104 STAMPED "22969" 0. 1 '(N) THE SOUTH 88 FEET OF THE NORTH 176 FEET OF HE WEST 137 R01FD ROOF/DRAIN / FOOTING DRAIN FEET OF TRACT 61, EDMONDS SEA VIEW TRACTS, ACCORDING TO • THE PLAT THEREOF RECORDED IN VOLUME 3 OF PLATS, PAGE 76, & . 01 '(E) OF CORNER. \ 1 \ YARD DRAIN (TYP.) I GFF GARAGE FINISHED FLOOR RECORDS OF SNOHOMISH COUNTY, WASHINGTON, ��n� l�I 7'/roil AT 0nnn�n i\\ - - - FOUND REBAR /� W CAP STAMPED Q "22969" 0.?l(N OF CORNER 1+00 <. 4 i t F ° ACCESS & UTILITY ASEMENT ° AFN-1926982 4" TO MAINTAIN CONTI NO US ( � 19210 METER CESS TO # 19210 & # 19204) & SERVICE' TA 1JR ON VIS, ao \ N CONS Zj�,ET a 19210 DRIVEWAY FOUNL) I V/ /IA/ \ a ELEVATION TOGETHER WITH AN EASEMENT FOR INGRESS, EGRESS AND UTILITIES AS RECORDED UNDER AUDITOR'S FILE NO'S 1926981 AND 1926982, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, AND, EQUIPMENT AND PROCEDURE SUBJECT TO EASEMENTS, RESTRICTIONS AND RESERVATIONS OF - X / METHOD OF SURVEY. RECORD. / SURVEY PERFORMED BY FIELD TRAVERSE (ALSO KNOWN AS PARCEL 2, CITY OF EDMONDS SHORT SUBDIVISION INSTRUMENTATION: #S-52-66, RECORDED (UNDER RECORDING N0. 8710230442) / LEICA TCRP 1201 ROBOTIC ELECTRONIC TOTAL STATION s� I a PRECISION: PARCEL NO. 00434600006105 THE WEST 137 FEET OF TRACT 61, EDMONDS SEA VIEW TRACTS, \ i MEETS OR EXCEEDS STATE STANDARDS WAC 332-130-090 ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 3 OF PLATS, ON PAGE 76, RECORDS OF SNOHOMISH COUNTY, I BASIS OF BEARING: WASHINGTON, \ I THE MONUMENTED CENTERLINE OF OLYMPIC VIEW DR. & 94TH AVE. W., EXCEPT THE NORTH 176 FEET THEREOF,• AND, AS THE BEARING OF N 89*11'25 W. 1 , TOGETHER WITH EASEMENTS FOR INGRESS, EGRESS AND UTILITIES Cp BM AS RECORDED UNDER AUDITOR'S FILE NO'S. 1926981 AND 1926982, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, AND, FOUND CASED CONC. MON. AT THE INTERSECTION OF 190TH PL. S.W. & 94TH AVE. W. RESUB SUBJECT TO EASEMENTS, RESTRICTIONS AND RESERVATIONS OF ELEV. = 253.68' RECORD. / PER GPS OBSERVATIONS A 25 2024 p r o DATUM: (ALSO KNOWN AS PARCEL 3, CITY OF EDMONDS SHORT SUBDIVISION I CITY OF EDMO NDS NAVD 88 DEVELOPMENT SERVICES #S-52-66, RECORDED (UNDER RECORDING NO. 8710230442) N.A.V.D 88-3.64'=NGVD '29 (MSL) DEPARTMENT PARCEL N0. 00434600006106 REFE y4LSO TO: IMPERVIOUS AREAS BREAKDOWN THE SOUTH 82 FEET OF TRACT 61, EDMONDS SEA VIEW TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 3 OF OW PERMIT #ENG2022-0926 SFR PERMIT #BLD2023-1286 LOT APGIS = 684 S.F. PLATS, ON PAGE 76, RECORDS OF SNOHOMISH COUNTY, WAHINGTON, = ,490 S.F. LOT A NPGIS 3 'SFR PERMIT #BLD2023-0287 3 I SFR PERMIT #BLD2022-1035 LOT B PGIS = 690 S.F. EXCEPT THE WEST 137 FEET THEREOF, I LOT B NPGIS = 3,473 S.F. SUBJECT TO EASEMENTS, RESTRICTIONS AND RESERVATIONS OF ��ST�RM REPORT PREPARED BY LOT C PGIS = 451 S.F. RECORD. a I l�O, APPROVED 5/12/2024 LOT CNPGIS = 3,563 S.F. ALL SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. \ EX. F H. LOT D PGIS = 750 S.F. LOT D NPGIS = 3,200 S.F. I ROAD = 5,664 S.F. TOTAL IMPERVIOUS AREA = 21,965 S.F. R=25.00' v P L=26.81 ' APPROVED FOR CONSTRUCTION I CITY OF EDMONDS IDATE: 5/13/2024 W/2 " BRASS DISK & "X ".j�"� NIC:HT E NC:I a [ R1 N. I BY: P.O. BOX - 1478 DOWN 0.6 . HELD FOR CITY ENGINEERING DIVISION EVERETT, WA 98206 (425) 303-9363 (425) 303-9362 FAX II I BEARI N'- INFO@INSIGHTENGINEERING.NET VISITED L — L / — L ( SITE ADDRESS: 9500 190TH ST SW & 19128, 19126, 19124, 19122 94TH AVE W 0 00 EDMONDS, WA 98020 /r TAX ACCOUNT NO.'S: 00434600006102, 00434600006104, REV, NO. DESCRIPTION INITIALS DATE 00434600006105, 00434600006106, I SHEETINDEX 00434600006201 I C1.0 COVER SHEET R j� c 1 1 ExlsriNc FEATURES MAP Q' �V wasp, �'J NE 114 SEC 13 T 27 N R 03 E W M C1.2 SLOPES MAP C2.0 GRADING & TESC PLAN C2.1 GRADING & TESC NOTES AND DETAILS TEXTUAL SITEDATA- C3.0 ROAD, DRAINAGE, & UTILITY PLAN C3.1 ROAD, DRAINAGE & UTILITY PROFILES C3.2 DETENTION PLAN & DETAILS WATER SOURCE/PURVEYOR:................................. CITY OF EDMONDS WATER SYSTEM C3.3 SEWER PROFILE SEWAGE DISPOSAL/PURVEYOR: ................................. EDMONDS WASTEWATER TREATMENT C3.4 OFFSITE SEWER PLAN SCHOOL DISTRICT. • ... ...... ...................... EDMONDS SCHOOL DISTRICT 15 C4. 0 FRONTAGE IMPROVEMENTS FIRE AUTHORITY. ••• •••••• ..................•••• SOUTH COUNTY FIRE C5.0 GENERAL NOTES &DETAILS ELECTRICITY.• ••• •••••• ..................•••• SNOHOMISH COUNTY PUD CABLE: COMCAST GAS: ••• •••••• ..................•••• PUGET SOUND ENERGY 0411612024 IRON VISTA DWG FILENAME DESIGNED BY.• DATE. SCALE. JOB NO.: 201094-FINAL-ROAD.DWG I DNK 0510212022 1 "=10' 20-1094 SHEET COVER SHEET iCL O NE 114, SEC. 13, T. 27 N., R.03 E., W.M. SNOHOMISH COUNTY, WASHINGTON (COMMCTOR TO WORK AND COORDINATE WRH UTILITY PROVIDER TO BRACE POLE DURING CONSTRUCTION) N 79°5033" W 3.94 :'� 9510 190TH PL. SW. (SHALL HAVE ACCESS TO PROPERTY AT ALL TIMES DURING CONSTRUCTION) 00434600008002 RESTORE WALLS TO EXISTING CONDITION AFTER PIPE INSTALLATION. 0 0 z 190,vNeL. o_ S •m x_ JLL L N 89°1523" W 50.00' 7 r. W N 0 0 00434600006103 SCALE: I" = 20' 20 10 0 20 40 RES U B Apr 25 2024 N 89°15'23" W 137.00' CITY OF EDMONDS TBR TO BE REMOVED I DEVELOPMENT SERVICES >< DEPARTMENT I TREE TO BE REMOVED PARCEL A 9 1°` o I / •� o TREES TO BE RETAINED { z APPROVED FOR CONSTRU CITY OF EDMONDS CITY OF EDMONDS SP #S-44-79 VOL. 1659, PGS. 1928-1936 1� I c co W n. o, G O z PARCEL B PRIVATE PUBLIC N 89°15'23" W 137.00' X%17.00' N 89°15" EXG SIDE SEWER TO 19204 TO BE CONNECTED TO REPLACED SIDE SEWER 19120 94TH AVE W 00434600006101 N 89°15'23" W 180.42' 4/ w I 1 x1 w (TO BE ABANDONED AND NEW CONNECTION TO BE PROVIDED TO LOT D) :E PROTECTION R EXCAVATION (TO REMAIN) EX. F.H. ?EPORT FOR 70N MEASURES. / R=25.00' / L=26.81' 158.00' 19204 DRIVEWAY \-Exo SIDE SEWER TO 19210 TO REPLACED SIDE SEWER 19210 DRIVEWAY NOTE. ONSITE WATER TO BE SUPPLIED VIA WATER TRUCK FOR ALL REQUIRED WATER DURING CONSTRUCTION. (TO REMAIN) �36 62 - 264, - - 9 /Zih =211.23 NE 1/4, SEC. 13, T. 27 N., R. 03 E., W.M. 1 1�jpL • s \ - 2� E 2 0' , 2.2' SNOHOMISH COUNTY, WASHINGTON / / \ 9�r YD RIM=211.32 RIM=211.62 /2.8x7.0' LID S ' /' / / c ; I, ASPHALT / LOT AREA 24,274 SF x I 00434600006201 �,. Yd RIM=211.22 Go� / // I 17 .24 ,h II 11 I I v 172.34 I I I I I I I I U / I x Iv` / I I OST % \ I / l • CD RIM=215.57 00434600006203 I I I ICTOR TO WORK AND IATE WITH UTILITY PROVIDER TO PST DOLE DURING CONSTRUCTION) l 1� I I O _ N 79°50'33' W 3.94 /\ I L POST q � / z I I I I I HOUSE FOUND REBAR/ /ILLEGIBLE CAP 0.6'(N) I I I I I POET \ 19500 & 0.2'(W) OF CORNER I I I I �' ° YD W=217.16 SCALE' 1 = 20 I I I \ I I POST I /e. (J IFOUND 1 /3 4" IRON I �' I 1 I P I RIM=215.05 I PIPE 1.0'(N) & \ I � I \1 I II POS� / .. 20 10 0 20 40 1 \\ \\ / / 0.3'(W) OF CORNER I z II \\ i I POST O O� e 190TH PL. SW. IIp ° _ HAVE ACCESS 'OPERTY AT ALL I I I I I T AES DURING NSTRUCTION) I I I \ ° I N 0434600008002� 4ESTORE WALLS TO EXISTING I 1� I a 7N AFTER PIPE INSTALLATION I I I 1 \ _ l I l �y YD RIM=213.98 / I I FOUND REBAR I I W/ILLEGIBLE CAP IA - I 11,9._ OF/CORN R 1 I ------- / FOUND REBAR W/CAP N I I ► d l / o, STAMPED '22969" 0.1 '(N) & 0.1 '(W) OF CORNER 0 I I I A I ID REBAR W/CAP STAMPED \\ \ \ \ I \ II II II I I I 79" 0.4'(N) OF CORNER � " � Q5✓ ,�� _/_ _ _ 1 / II FENCE COR. 0.2'(E) OF I �' n / / �� + 1 PR PERTY LINE � I I _ - - - _ . / I / _ 00434600006103 I I SEE DETAIL 'B' I, I \ \ \\ \\ I I I----------------------------------------------------- �I- _ J _ j I 8 • OUND REBAR W/CAP STAMPED 1 co I - FOUND REBAR W/CAP 122969" 0.1 '(N) OF CORNER I I I I I I STAMPED '22969" 0.2'(W) OF CORNER. FENCE 0.4'(W) AT CORNER I I III / I I I PARCEL A i I PROPOSED BLOCK WALL I I Alo � I I l� I 3Ic o I I � ACCESS &UTILITY � � -�- I D o FOUND REBAR W/CAP I I L T D I STAMPED '22688" 0.4'(S) I I ro / I EASEMENT I I I & 0.1 '(W) OF CORNER. Ai N-1926981 I \ I FENCE 0.1 '(W) AT CORNER I I o / z*I CITY OF EDMONDS I I I I I I SP #S-44-79 \ - I / 19120 94TH AVE W 15 VOL. 1659, PGS. 1928-1936 / EX R/ 3 15' l / 00434600006101 \ EX. R/W I FOUND REBAR c, 1 I W/CAP STAMPED I �' 22969" 0.2'(N) I 1 I I 1 1/ 04346000\ OF CORNER FOUND REBAR W/CAP �\ / \ FOUND REBAR W/CAP STAMPED '22969" 0.1 '(N) FOUND REBAR W CAP"I 1 - - I _ _ N / STAMPED '22969" 0.2' N \ \ (TO REMAIN) & .01' E OF CORNER. �� o I WICAP - - -!- - ' 15 23" W 137.00' \ () () � \ STAMPED '22969" 0.3'(W) I l / % - - \ & 0.1' E OF CORNER FENCE 1.7'(W) AT CORNER I CB RIM=265.01 & 0.4'(N) OF CORNER ° / \ 1 IE 12" CPP(N)=260.56 FENCE 0.2'(W) AT CORNEA l� / / \ \ \ \ I - / I I I IE 12" CMP(W)=262.76 --� 9" \ / ►� I I/ I/ \ H PARCEL e I � / ,// � � 1 \I \ � \ \\� // • �� 1 I l� I 1 I I I \ \\ ' / I CB RIM=265.84 OT AREA IE 12" CMP(E)=263.64 IE 12" CPP(S)=264.09 III I v n ACCESS & UTILITY EASEMENTI0 I GAZEEBO 1 AFN-202006240176 / / I I I G / // rv� rnr cri�rn rn rf' nn I Ico. 3 I I I \ / / \ , LINE OF EASEMENT AFN-1964542. (TO BE ABANDONED AND NEW I l l / CONNECTION TO BE PROVIDED TO LOT D) I 1 I I EASEMENT RUNS ALONG SOUTHERN PROPERTY LINE AND IS FULLY I I T / / / / LOT D l ENCOMPASSED BY AFN-202006240176 EX. F.H. SSMH RIM:209.E) 03 IE 20II II \\ 1 FOUND IEBAR IE 203.85 (OUT, S) , 1 1 1 I I 1 45" SSCO \ \ ACCESS &UTILITY W/CAP STAMPED I / I � ` I I / RIM:256.29 \ \ EASEMENT 1 22969" 0.21'1(N) AFN-1926 81 ,---OF CORNF�}7 co FOUND CASED CONC. MON. 1 IE: 248.29 \ 1 O I I J�jASS SS I-- \ W/2" BRASS DISK & 'X". 1 \ \ DOWN 0.6'. HELD FOR I 1 I` - \� \ II \\ BEARING - - - -- -------------------- _ � 1 0 ° � VISITEQ 2-27-20. FOUND REBAR W/ILLEGIBLE CAP N 89.1523 W 1650.00'(R1) 649.90'(MI I I I I 2" / 0.7'(W) & 0.1'(S) OF CORNER. N 89`11 25" 'W 649.91'(M)(MON 'TO MON) I F ( A \ - ° \ a . . a CO R { I / �L e \ 19204 DRIVEWAY ° ! N� I FOUND 1-1/2" IRON PIPE FENCE COR. 0.3'(N) & I I I I I FOUND REBAR W CAP STAMPED \ � ��- 0.4'(W) OF CORNER. I EXG SIDE SEWER TO EXSS6LINE TO " CONC.'22969" 0.1'(S) & 0.5'(W) OF CORNER �- I /' -- IE 12" RCP=266.86 I� 19204 TO BE CONNECTED 19 0 DRIVEWAY TO REPLACED SIDE SEWER BE REPLACED I EXG SIDE SEWER TO 19210 ACCESS & UTILITY EASEMENT ° ° X. WATER IE 12" RCP=267.17 a I TO REPLACED SIDE SEWER AFN-1926982 a ETERS / I END FENCE PROPERTY LINE $ (TO MAINTAIN CONTINOUS FOUND TACK I LEAD \ I #19210 METER � ACCESS TO #19210 & #19204) 'W/WASHER STAMPED / #19204 I (TO REMAIN) ,'22969" 0.2'(N) OF CORNER AAFTFR Ie, CFRIII(`F I CCA40 IDIAA-990 79 / RES U B Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOR REFERENCE ONLY AREAS BETWEEN 25 - 40% SLOPE (24,946 SF) AREAS ABOVE 40% SLOPE (3,589 SF) 1- CB 6 62 264\ % -PI =211.23 NE 1/4, SEC. 13, T. 27 N., R. 03 E., W.M. RIM=178.18 / I \ ?` / / / / /13 ' I L• S \ - % ��' 6'2�" E 2.2 SNOHOMISH COUNTY WASHINGTON �22 / 2.0' / / � i / isSO' _ \ \ l / YD RIM=211.32 Y RIM=211.62 6• / i i / f �� / /2.8 x7.0' LID ASPHALT r 10 C- S //.� // F� I II ��\ 1 // / / 4.1'// I ! ` LOT AREA - - - / / / 24,/2�74 TSF/Y IIi I RIM=211.22 00434600006201 DEC - CL �'CB�714 DI IE 12" CP(W)=17 .24 v 0� � 8�DE\ o IE 12" kP(E)=172.34 l 24/ /KFosT - /RIM-215.57LQ 00434600006203 �/�� I I / (CONTRACTOR TO WORK AND COORDINATE WMI UTILITYPST PRO W BRACE POLE DURING CONSTRUCTION 1) L I 10 /� // \ I 10" / / I ID o N 79°5033 �' W 8.9 I l POST / I �j z -� _ `cS HOUSE /� _ y I I / x 3 / l ) 8» / FOUND REBAR I I I POT \ 19500 c I �DE j . 1/ILLEGIBLE CAP 0.6'(N) i/ I a \ / � I / / / & 0.2'(W) OF CORNER ` \ I \ Y I YD W=217.16 PO([7\T I _ 1 g '° V /A r C / FOUND 1 -3/4" IRON \ I ` ` \ I I i P� / I RIM=215.05 PIPE 1.0'(N) & I N I I I POS\f 0.3'(W) OF CORNER \, ` ` \\ I I POST 10" 9510 190TH PL. SW. I I I I I O (SHALL HAVE ACCESS r/ I I\ I w I \ \ I C C 14" TO PROPERTY AT ALL I \ I I T o I� / I i i 12" //C C 24» \ TIMES DURING I N I \ I/. / /12" CONSTRUCTION) I I I / ) \ ° °, / / _ C / 00434600008002i n -4 a C / C �C RESTORE WALLS TO EXISTING I \ 1 I / \ 5 - CONDMON AFTER PIPE INSTALLATION. to - YD R -----------IM/=2/13.98 7 W/ /,2q8 C / _ N i 110.1 A i\ -)UND REBAR W/CAP --- \ AMPED 22969 0.1 (N) 0.1 '(W) OF CORNER o z \ 1 \ I \ \\ I a \ \HOLZ\Y TP- log ` '� \ I 1 I 1 \ 1 \\ 11 \ I II 1 I I I \ �- IVI •TOE: 250 00 I ` \ LOT A \\ \ 1 LOT\ REA\ FOUND REBAR W/CAP STAMPED 1�056\ , SF 11 \ 1 II I "17679" 0.4'(N) OF CORNER \\ \ \ 1 1 1 I I I 1 II I 1 \ \ 1 I I \0043 6000Q610� \ \ 1 I I I FENCE COR. 0.2'(Fl nr -------------- 9' TOP/ 250.25 ERN LINE \ \ \ I OE: 247.50 \ - _ - - IV 89' 15 23" W, 5 .00' SEE DETAIL ,B, , Existing Significant trees 50 Significant Note: non -viable trees are dead or "poor" condition Non -viable trees 0 trees, subject to review Total # viable site -wide 50 (A) Trees CRITICAL AREAS CRITICAL AREAS 16 (B) Retained Trees #36-51 Total # retained trees Proposed Tree DEVELOPABLE AREAS DEVELOPABLE AREA Retention Retained Trees #1-11 Total # viable trees 13 (C) DEVELOPABLE AREA Note: viable are at least "fair" condition trees, subject 11 (D) to review Retained viable trees REQUIRED TREE REPLACEMENT CALCULATIONS Removed # Removed Replacement Total # New Proposed Tree Tree DBH Ratio Trees 6-10" 14 x1 = 14 Removals TOTAL # VIABLE TREE REMOVALS: 23 & Removed Trees #12-34 1 Required 10.1-14" x2 = 2 = 31(E) Replacements (Tree #26) 14.1-24" 5 x3 = 15 *Total Appraised >24" 3 Value $1 Minimum 30% retention in Proposed Does applicant meet/exceed 30% tree retention threshold? Yes: replant to replace removals only (E) developable area (C x .3) (D) No: replant to meet threshold(2) and replant Tree Retention 13 x .3 = 4 trees = 11 trees removals unless infeasible(3) Thresholds Minimum 50% retention Proposed Does applicant meet/exceed 50% tree retention threshold? required site -wide (A x .5) (B+D) Yes: waive all fees in lieu, replant removals (E) 50 x .5 = 25 trees = 27 trees No: replant and/or pay fees in lieu (E, 1, 2,3) 'Total appraised value of all removed existing viable trees over 24" DBH* = $? 2 Is it infeasible to replant to meet minimum tree retention threshold? Yes: fee in lieu = $? Fees in Lieu 3IS it infeasible to replace removed significant viable trees? Yes: fee in lieu = $? *OPTION: reduce fees in lieu total by using the $2 per square foot lot area "cap" *OPTION: waive all fees in lieu using the 50% retention threshold via ECDC 20.75.048 / / l N 89°15'23" W 137.00' �I \ I 1 TOE _BAR W/CAP STAMPED � - I 22969» 0.1 (N) OF CORNER FOUND REBAR W/CAP 4 I I / M STAMPED »22969" 0.2'(W) TP-1/ l / / / / / I OF CORNER. FENCE 0.4'(W) AT CORNER II I / / / / / / / 34 / / PROPOSED BLOCK WALL PARCEL A I I \ I TOP: 254.00 \. I / / I / / / / / o TOE: 250.00 FOUND REBAR W/CAP I ` \ / Do w UTILITY EASEMENT STAMPED 22688" 0.4'(S) I N I \ \\ \ / i I I LOT B (/ / / / / 00 / AFN-1926981 & 0.1 '(W) OF CORNER. FENCE 0.1 '(W) AT CORNER m / CL CITY OF EDMDNDS SP #S-44-79 \ I \ \\ I I I I I I®\ VOL. 1659, PGS. 1928-1936 F k I I I 1 I - - - \LOT AREA 1q,05\¢ S� \ \\ \\ \ 1 I \ 18 \\ TOP: , p0 APED I / I ( 1 1 \ \ 1 1 i 0434600�06 M4 \ \ \ \ I 1 \ H I I TOE R '(N) I I V g I I 1 I I I TP-3 \ \ \ \ 11 1\ \ `\ \\� I I 1 . SS \ / - \ \ \ \ �� I FOUND REBAR W/CAP FOUND REBAR W CAP I I - - \ / I ,� I � STAMPED '22969» 0.2'(N) STAMPED »22969" 0.3'(W) l l IA_ % / / - - - - \ _ & 0.1 ' E OF CORNER 1 & 0.4'(N) OF CORNER./ \ / \ , FENCE 0.2'(W) AT CORNER \ `\ \ \ 1 1 I, \ \ �\ \ l 1/ ,/ l �T )• 252.00 / / • 6' x / / / / / / / / / / / / 0 ''. 2 PARCEL 8 H :CC 1 x / L,,�� / / / �- I TEMP. CON ENTRrWCE I \ �-I - / /j' I ," 12�056 SF _ /' / / / / / (CONT►NOUS ACCESS TL 19210 x I I I -I -G EEB 0 AND 19204 947H AVE W SHALL BE ACCESS & UTILITY EASEMENTI 4 J I I 100 3460g00610t 1 MAINTAINED DURING CONSTRUCTION) AFN-202006240176 II I /+ G�3 I / I I \ I I I // / \ - c• LINE OF EASEMENT AFN-1964542. I I x 1 „ I � 1 T -41 I 1 1 � // � F / j / (TO BE ABANDONED AND NEW ) I I 1 I / CONNECTION TO BE PROVIDED TO LOT D EASEMENT RUNS ALONG SOUTHERN I 1 I It / I 1 I 1_ PROPERTY LINE AND IS FULLY 1 / I I I 1 I LOT C / \ 221 / ENCOMPASSED BY AFN-2020062SSMH II I \ k 1 IJ 25 j30 I / I \� I I �I RIM:209.03 IE. 203.95 (IN, E) I� IE: 203.85 (OUT, s) /I I � � � I I II l l 2 11 IgII I I I I I E I I 6 �/ \ FOUND REBAR W/ILLEGIBLE CAP N 89'15'23' W 1350.00'(R1) 649.90'(M) I I 2" / 0.7'(W) & 0.1'(S) OF CORNER. N 89.11 25» W 649.91'(M)(MON TO MON) I I F 2/ / / CW 19204 DRIVEWAY PASIS OF E.' 5 L FENCE COR. 0.3'(N) & I I FOUND REBAR W CAP STAMPED 0.4'(W) OF CORNER. I I I EXG SIDE SEWER TO \ EXG 6" CONC. 22969" 0.1 '(S) & 0.5'(W) OF CORNER VG cn I 19204 TO BE CONNECTED SS LINE TD E SEWER TO 19210 I TO REPLACED SIDE SEWER REPLACED i \ 1 TO REPLACED SIDE SEWER END FENCE 0.05'(N) OF PROPERTY LINE $ I #19204 ' METER & SERVICE I 19204 94TH AVE W - (TO RaWNy) I � I .5' FA.SFMFNT I REPLACEMENT TREES REQUIRED: 31 REPLACEMENT TREES PLANTED: 42 LOT -A: 14 NEW TREES LOT-B: 14 NEW TREES LOT-C: 14 NEW TREES LOT-D: NO CONSTRUCTION ACTIVITY 42 TOTAL NEW TREES PLANTED ON LOTS A, B & C 00434600006103 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE 19120 94TH AVE W 00434600006101 ONSITE STORMWATER MANAGEMENT: THE 13 ELEMENTS OF SWPPP BMP BMP T5.13 POST -CONSTRUCTION SOIL QUALITYAND DEPTH. ELEMENT #1 - MARK CLEARING LIMITS: LIMIT OF CONSTRUCTION ARE CLEARLY MARKED. SOIL RETENTION: THE DUFF LAYER AND NATIVE TOPSOIL SHOULD BE RETAINED IN AN UNDISTURBED STATE TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY AREAS REQUIRING GRADING REMOVED AND ELEMENT #2 - ESTABLISH CONSTRUCTION ACCESS: STOCKPILE THE DUFF LATER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT A STABILIZED CONSTRUCTION ENTRANCE IS SHOWN. ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. ELEMENT #3 -CONTROL FLOW RATES: FLOW IS MINIMAL. SOIL QUALITY: ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL ELEMENT #4 - INSTALL SEDIMENT CONTROLS: OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE FOLLOWING: SILT FENCE, INLET PROTECTION, MULCH ARE PROPOSED. CATCH BASIN INLET PROTECTION PROVIDED BY STORMWATER FILTERS WILL BE 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF TEN PERCENT DRY WEIGHT IN INSTALLED IN ALL CATCH BASINS WITHIN 500 FEET DOWNSTREAM OF PLANTING BEDS, AND 57. ORGANIC MATTER CONTENT (BASED ON A LOSS ON -IGNITION TEST) IN THE PROJECT SITE. TURF AREAS, AND A PH FROM 6.0 TO 8.0 OR MATCHING THE PH OF THE ORIGINAL UNDISTURBED ELEMENT #5 - STABILIZE SOILS: SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SOIL STABILIZATION IS ACHIEVED BY MULCHING, PLASTIC COVERING AND SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME SEEDS. INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. ELEMENT #6 -PROTECT SLOPES: 2. PLANTING BEDS MUST BE MULCHED WITH 2 INCHES OF ORGANIC MATERIAL SLOPES ARE PROTECTED BY PLASTIC COVERING, MULCHING AND SEEDS. 3. QUALITY OF COMPOST AND OTHER MATERIALS USED TO MEET THE ORGANIC CONTENT REQUIREMENTS: ELEMENT #7- PROTECT DRAIN INLETS: INLET PROTECTIONS ARE PROPOSED FOR THE STORM DRAINS. A. THE ORGANIC CONTENT FOR PRE -APPROVED" AMENDMENT RATES CAN BE MET ONLY USING "COMPOSTED ELEMENT#8 - STABILIZE CHANNELS AND OUTLETS: COMPOST THAT MEETS THE DEFINITION OF MATERIALS" IN WAC 173-350-220. THIS N/A. CODE IS AVAILABLE ONLINE AT. http://www.ecv.wo.govaroprogram/swfa/facilities/350.html. COMPOST USED IN BIORETENTION AREAS SHOULD BE STABLE, MATURE AND DERIVED FROM YARD ELEMENT #9 - CONTROL POLLUTANTS: DEBRIS, WOOD WASTE, OR OTHER ORGANIC MATERIALS THAT MEET THE INTENT OF THE ORGANIC ALL VEHICLES, EQUIPMENT AND PETROLEUM PRODUCT SOIL AMENDMENT SPECIFICATIONS. BIOSOLIDS AND MANURE COMPOSTS CAN BE HIGHER IN STORAGE/DISPERSING AREAS WILL BE INSPECTED REGULARLY TO BIO-AVAILABLE PHOSPHORUS THAN COMPOST DERIVED FROM YARD OR PLANT WASTE AND DETECT ANY LEAKS OF SPILLS, AND TO IDENTIFY MAINTENANCE NEEDS THEREFORE ARE NOT ALLOWED IN BIORETENTION AREAS DUE TO THE POSSIBILITY OF EXPORTING AND PREVENT LEAKS OF SPILLS. BIO-AVAILABLE PHOSPHORUS IN EFFLUENT. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 35% TO 6590, AND CARBON TO NITROGEN RATION BELOW 25:1. THE CARBON TO ELEMENT #10 - CONTROL DEWATERING: NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTING COMPOSED ENTIRELY OF PLANTS THERE WILL BE NO DEWATERING AS PART OF THIS CONSTRUCTION NATIVE TO THE PUGET SOUND LOWLANDS REGION. PROJECT. B. CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIALS AS ELEMENT #11- MAINTAIN BMP's: DEFINED ABOVE, OR ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO ALL TEST BMPs SHALL BE MAINTAINED AND REPAIRED AS NEEDED. REQUIREMENTS, AND MEETING THE CONTAMINANT STANDARDS OF GRADE A COMPOST. ELEMENT #12 - MANAGE THE PROJECT.• THIS COULD BE ACHIEVED BY MINIMIZING THE EXTENT AND DURATION CONSTRUCTIONSEQUENCE OF THE AREA EXPOSED AND BY EMPHASIZING EROSION CONTROL THEN SEDIMENT CONTROL. 1. PRIOR TO CONSTRUCTION ACTIVITIES, THE CONTRACTOR SHALL SCHEDULE AND ATTEND PRE -CONSTRUCTION CONFERENCE WITH THE ELEMENT #13 - PROTECT ON -SITE STORMWATER MANAGEMENT BMP'S CITY ENGINEERING DIVISION THROUGH MYBUILDINGPERMIT AND FOR RUNOFF FROM ROOFS AND OTHER HARD SURFACES: N/A. REQUESTED VIAL EMAIL AT ENGINEERINGPERMITSQEDMONDSWA.GOV. TWO DAYS (48 HRS) NOTICE IS REQUIRED. 2. FLAG CLEARING LIMITS AND INSTALL SILT FENCE AS SHOWN. 3. INSTALL ROCK CONSTRUCTION ENTRANCE. 4. CLEAR AND GRUB ROAD AREAS, AND STOCKPILE AREAS. STOCKPILE IS TO BE COVERED WITHIN 24 HOURS. 5. GRADE AND STABILIZE ROAD WITH GRAVEL BASE. COVER EXPOSED SOILS WITH MULCH, HOG FUEL OR HYDROSEED. 6. INSTALL EROSION CONTROL BMP'S. INSTALL CATCH BASIN INLET PROTECTION TO ANY CATCH BASINS DOWSTREAM OF THE CONSTRUCTION SITE. 7. COVER EXPOSED SOILS WITH MULCH, HOG FUEL OR HYDROSEED. 8. CONSTRUCT SEWER, WATER AND STORM UTILITIES. INSTALL GAS, POWER, TELEPHONE AND CABLE UTILITIES, AS REQUIRED. WATER SHALL � � REMAIN AT THE I � F�OW/AVBNSTRUCTION AND SHALL BE SCALE: 1 = 20� PROTECTED BY A BA 9. PAVE ROADS WITH ATB AND PLACE DETENTION SYSTEM INTO FULL OPERATION. 20 10 0 20 40 10. HYDROSEED REMAINING EXPOSED SOILS AND STABILIZE PROJECT. R E S U B 11. REMOVE SEDIMENTATION TRAPPED SEDIMENT SHALL BE REMOVED OR Apr 25 2024 STABILIZED ON SITE. DISTURBED SOIL AREAS RESULTING FROM REMOVAL SHALL BE PERMANENTLY STABILIZED. CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED I WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY BMP's ARE NO LONGER NEEDED. I N to I E I I= I II I KC I I I I 3 60 � � I I I 15' I I I I 15' I tX. R/W 6 � F 20" F I � �� \I it • _ I / FOUND REBAR W/CAP (TO REIWN) / STAMPED '22969" 0.1'(N) j & . 01 '(E) OF CORNER. \ �� FENCE 1.7'(W) AT CORNER CB RIM=265.01 IE 12" CPP(N)=260.56 F IE 12" CMP(W)=262.76 6 � ,�� \ 22" C 3 TFF= 280.24 I /MFF= 270 \ I I / 9/ , o 11 C BFF= 260.67 2 0 I I / / CB RIM=265.84 /i IE 12" CMP(E)=263.64 F ° /� \ t IE 12" CPP(S)=264.09 17" 1 I I 1 \ \V 10 I b 3 8 l.- LOT D x =�P-7 �x X-X I► i/ \ I I EX. F.H. C A As 4 1 COZY I . F 19210 DRIVEWAY - ACCESS & UTILITY EASEMENT X. WAT AFN-1926982 • 4» / 4f ETERS (TO MAINTAIN CONTINOUS #19210 METER FOUND TACK I LEAD ACCESS TO #19210 & #19`) & SERVIC tN/WASHER STAMPED (TO RL]WAINj° . ,'22969" 0.2'(N) OF CORNER SSMH RIM=269.76 19210 94TH AVE W / I IE 8" PVC(S)=261.86 IE 8" PVC(E)=261.86 IE 8" PVC(N)=261.76 I ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF DMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. UTILITY CONTLICT NOTE.° Know what's below. CAUTION.° Call before you dig. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. NOTE.- 1. GEOTECH MUST MONITOR CONSTRUCTION AND PROVIDE DIRECTION FOR PLACING FILL, FOUNDATIONS, AND WALL CONSTRUCTION. 2. ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T-5.13. 3,532 SQUARE YARDS OF SOIL SHALL BE COMPOST AMENDED. 3. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE TO MAINTAIN, REVISED AND/OR ADJUST ESC MEASURES AS NEEDED THROUGHOUT CONSTRUCTION UNTIL PERMANENT STABILIZATION IS IMPLEMENTED. 4. SEE GEOTECHNICAL REPORT FOR SOIL LOGS. 5. MAINTAIN CONTINUOUS ACCESS TO EXISTING HOMES ON 19204 AND 19210 94TH AVE W DURING CONSTRUCTION. FOUND CASED CONC. MON. W/2" BRASS DISK & 'X': DOWN 0.6'. HELD FOR BEARING VISITEQ 2-27-20. I FOUND 1-1/2" IRON PIPE IE 12" RCP=266.86 \ / IE 12" RCP=26Z 17 19�A T�, - � *0 REPLACEMENT TREE 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL N NATIVE BACKFILL MATERIAL 8" FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS, WIRE MESH FENCE �I TO ABRICPPORT FILTER (V BURY BOTTOM OF FILTER a MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN FILTER FABRIC FENCE FILTRATION SYSTEMS APPROVED BY: R. ENGLISH 1 FILTER FABR[CFENCEDETAIL C2.I NTS CITY OF EDMONDS STD DTL ER-900 CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CATCH BASIN GRATE REVISION DATE JANUARY 2018 STANDARD DETAIL ER-900 FILTER SOCK WITH OVER FLOW HOLES (TYP) CATCH BASIN NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY SEDIMENT TRAP FOR CATCH BASINS APPROVED BY: R. ENGLISH 3 TEMPORARYSEDIMENT TRAP CZ.I NTS CITY OF EDMONDS STD DTL ER-902 REVISION DATE JANUARY 2018 STANDARD DETAIL ER-902 NE 114, SEC. 13, T. 27 X , R. 03 E., W.M. SNOHOMISH COUNTY, WASHINGTON _LS A TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: 1O THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O2 ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 -71 QSt. 189 * PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN CITY OF EDMONDS STABILIZED CONSTRUCTION ENTRANCE PUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH STABILIZED CONSTRUCTIONENTRANCE NOT TO SCALE CITY OF EDMODNS STD DTL ER-901 CONTOUR LINE (TYP) ANGLE TERMINAL END UPHILL 24" TO 48" TO PREVENT FLOW AROUND WATTLE (TYP) WATTLE TRENCH, SEE NOTE 2 --\ `2"x2"x24" UN -TREATED WOODEN STAKE (TYP) AREA AVAILABLE FOR SPACING VARIES SEDIMENT TRAPPING SEE WATTLE SPACING (TYP) TABLE (TYP) SWATTLE EE DETAIL(TYP) 2" MIN 5" MAN REVISION DATE JANUARY 2018 STANDARD DETAIL ER-901 2"x0x24" UN -TREATED WOODEN STAKE (TYP) �3" MIN 4" MAX 8" DIAMETER MIN WATTLE DETAIL 8" DIAMETER SPACING WATTLE TABLE SLOPE MAXIMUM SPACING 1HAV 10'-0" 2H:1V 20'-0" 3H:1V 30'-0" 4H:1V 40'-0" >4H:1V ONE RUN ONLY NOTES: 1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION. 2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS. INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10). 3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT UNDERCUTTING. 4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. `St. 18yv REVISION DATE CITY OF EDMONDS JANUARY 2018 WATTLE INSTALLATION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH E R - 9 03 4 WATTLE INSTALLATION CZ.1 NTS CITY OF EDMONDS STD DTL ER-903 UTILITYCONFLICTNOTE Know what's below. CAUTION.' Call before you dig. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. ESC NOTES (ECDC 18.30.050) A. ESC MINIMUM REQUIREMENTS. ALL ACTIVITIES NECESSITATING A CLEARING OR GRADING PERMIT AND ALL UTILITY PROJECTS CONSISTING OF MORE THAN 500 LINEAL FEET OF TRENCH EXCAVATION SHALL BE REQUIRED TO CONTROL EROSION AND SEDIMENT DURING CONSTRUCTION AND TO PERMANENTLY STABILIZE EXPOSED SOIL RESULTING FROM CONSTRUCTION. PROJECTS INVOLVING A CRITICAL AREA MAY ALSO BE REQUIRED TO COMPLY WITH ANY COMBINATION OF THE ESC MINIMUM REQUIREMENTS. COMPLIANCE WILL BE DEMONSTRATED THROUGH THE IMPLEMENTATION OF AN APPROVED ESC PLAN. GUIDELINES FOR PREPARING ESC PLANS ARE PROVIDED IN THE MANUAL. THE PLAN MUST ADDRESS THE FOLLOWING REQUIREMENTS: 1. ESC MINIMUM REQUIREMENT - CONSTRUCTION ACCESS ROUTE. CONSTRUCTION VEHICLE ACCESS SHALL BE, WHENEVER PRACTICAL, LIMITED TO ONE ROUTE. ACCESS POINTS SHALL BE STABILIZED WITH QUARRY SPALLS OR CRUSHED ROCK TO MINIMIZE THE TRACKING OF SEDIMENT ONTO PUBLIC ROADS. IF SEDIMENT IS TRANSPORTED ONTO A ROAD SURFACE, THE ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM ROADS BY SHOVELING OR SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA WITHIN 24 HOURS. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. 2. ESC MINIMUM REQUIREMENT - STABILIZATION OF EXPOSED AREAS. ALL SOILS EXPOSED BY LAND DISTURBING ACTIVITIES SHALL BE STABILIZED BY SUITABLE APPLICATION OF BMPS, INCLUDING, BUT NOT LIMITED TO, SOD, HYDROSEEDING, OR OTHER VEGETATION, PLASTIC COVERING, OR MULCHING. ALL BMPS SHALL BE SELECTED, DESIGNED, AND MAINTAINED IN ACCORDANCE WITH THE MANUAL. THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO AN APPROVED TIMETABLE. (TYPICALLY, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM OCTOBER 1 THROUGH APRIL 30 AND NO MORE THAN SEVEN DAYS FROM MAY 1 THROUGH SEPTEMBER 30). 3. ESC MINIMUM REQUIREMENT - PROTECTION OF ADJACENT PROPERTIES. ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION BY APPROPRIATE USE OF VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS OR FILTERS, DIKES OR MULCHING, OR BY A COMBINATION OF THESE MEASURES AND OTHER APPROPRIATE BMPS. 4. ESC MINIMUM REQUIREMENT - MAINTENANCE. ALL EROSION AND SEDIMENT CONTROL BMPS SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE OWNER TO ENSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. ALL MAINTENANCE AND REPAIR SHALL BE CONDUCTED IN ACCORDANCE WITH THE MANUAL. 5. ESC MINIMUM REQUIREMENT - OTHER BMPS. AS REQUIRED BY THE CITY, OTHER APPROPRIATE BMPS TO MITIGATE THE EFFECTS OF INCREASED RUNOFF SHALL BE APPLIED. 6. EROSION AND SEDIMENT CONTROL REQUIREMENT - UNDERGROUND UTILITY CONSTRUCTION. THE CONSTRUCTION OF UNDERGROUND UTILITY LINES SHALL SPECIFICALLY ADDRESS THE FOLLOWING: A. EROSION CONTROL FOR EXCAVATED AND STOCKPILED MATERIALS, B. THE PLACEMENT OF EXCAVATED MATERIAL WHERE CONSISTENT WITH SAFETY AND SPACE CONSIDERATIONS SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES, C. TRENCH DEWATERING SYSTEMS (MUST DISCHARGE INTO SEDIMENT TRAPS, SEDIMENT PONDS, OR OTHER ACCEPTABLE MEANS); D. TRACKING AND SPILLING OF MATERIALS ON STREETS DUE TO HAULING; E. DAILY CLEANUP AND STREET MAINTENANCE. 7. ADDITIONAL ESC MINIMUM REQUIREMENTS FOR LARGER DEVELOPMENTS. ALL NEW DEVELOPMENT AND REDEVELOPMENT THAT INCLUDES LAND DISTURBING ACTIVITIES OF GREATER THAN, OR EQUAL TO, ONE ACRE IN ADDITION TO MEETING THE MINIMUM REQUIREMENTS SET FORTH ABOVE SHALL COMPLY WITH ESC REQUIREMENTS LISTED BELOW. 8. ESC MINIMUM REQUIREMENT - DELINEATE CLEARING AND EASEMENT LIMITS. IN THE FIELD, MARK CLEARING LIMITS AND/OR ANY EASEMENTS, SETBACKS, SENSITIVE/CRITICAL AREAS AND THE BUFFERS, TREES AND DRAINAGE COURSES. 9. ESC MINIMUM REQUIREMENT - SEDIMENT TRAPPING. PRIOR TO LEAVING THE SITE, STORM WATER RUNOFF SHALL PASS THROUGH A SEDIMENT POND OR SEDIMENT TRAP, OR OTHER APPROPRIATE BMPS. SEDIMENT PONDS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS, AND OTHER BMPS INTENDED TO TRAP SEDIMENT ON -SITE SHALL BE CONSTRUCTED AS A FIRST STEP IN GRADING. THESE BMPS SHALL BE FUNCTIONAL BEFORE LAND DISTURBING ACTIVITIES TAKE PLACE EARTHEN STRUCTURES, SUCH AS DAMS, DIKES, AND DIVERSIONS SHALL BE SEEDED AND MULCHED ACCORDING TO AN APPROVED TIMETABLE. 10. ESC MINIMUM REQUIREMENT - CUT AND FILL SLOPES. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. IN ADDITION, SLOPES SHALL BE STABILIZED IN ACCORDANCE WITH ESC REQUIREMENT NO. 2. 11. ESC MINIMUM REQUIREMENT - CONTROLLING OFF -SITE EROSION. PROPERTIES AND WATER WAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM EROSION DUE TO INCREASES IN THE VOLUME, VELOCITY, AND PEAK FLOW RATE OF STORM WATER RUNOFF FROM THE PROJECT SITE. 12. ESC MINIMUM REQUIREMENT - STABILIZATION OF TEMPORARY CONVEYANCE CHANNELS AND OUTLETS. ALL TEMPORARY ON -SITE CONVEYANCE CHANNELS SHALL BE DESIGNED, CONSTRUCTED AND STABILIZED TO PREVENT EROSION FROM THE EXPECTED VELOCITY OF FLOW FROM A TWO-YEAR, 24-HOUR FREQUENCY STORM FOR THE DEVELOPED CONDITION. STABILIZATION ADEQUATE TO PREVENT EROSION OF OUTLETS, ADJACENT STREAM BANKS, SLOPES AND DOWNSTREAM REACHES SHALL BE PROVIDED AT THE OUTLETS OF ALL CONVEYANCE SYSTEMS. 13. ESC MINIMUM REQUIREMENT - STORM DRAIN INLET PROTECTION. ALL STORM DRAIN INLETS MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT STORM WATER RUNOFF SHALL NOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 14. ESC REQUIREMENT - REMOVAL OF TEMPORARY BMPS. ALL TEMPORARY EROSION AND SEDIMENT CONTROL BMPS SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY BMPS ARE NO LONGER NEEDED. TRAPPED SEDIMENT SHALL BE REMOVED OR STABILIZED ON SITE. DISTURBED SOIL AREAS RESULTING FROM REMOVAL SHALL BE PERMANENTLY STABILIZED. 15. EROSION AND SEDIMENT CONTROL REQUIREMENT - DEWATERING CONSTRUCTION SITES. DEWATERING SYSTEMS SHALL DISCHARGE INTO A SEDIMENT TRAP OR SEDIMENT POND. 16. EROSION AND SEDIMENT CONTROL REQUIREMENT - CONTROL OF POLLUTANTS OTHER THAN SEDIMENT ON CONSTRUCTION SITES. ALL POLLUTANTS OTHER THAN SEDIMENT THAT OCCUR ON SITE DURING CONSTRUCTION SHALL BE HANDLED AND DISPOSED OF IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF STORM WATER. 17. EROSION AND SEDIMENT CONTROL REQUIREMENT - FINANCIAL LIABILITY. PERFORMANCE BONDING, OR OTHER APPROPRIATE FINANCIAL INSTRUMENTS, SHALL BE REQUIRED FOR ALL PROJECTS TO ENSURE COMPLIANCE WITH THE APPROVED EROSION AND SEDIMENT CONTROL PLAN. CORD. 3013 § 1, 19951. RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W NE 114, SEC. 13, T. 27 X I R. 03 E., W.M. / S - ; ; ; �'� /''%' '��-� =211 SNOHOMISH COUNTY WASHINGTON CB RIM=178.18 1 IS �wx / i i i 6.62 / 2e4, 1A k" 9 01 i // �' \ ! �� �\ l / YD RIM=211.32 1 I (" ,' �' / J �• / i I AS�HA I SS \I , / / �/i / / / \ \ ASPHALT , -SS ^ S �/ �/ / �/ /�/' I I I �� 1 / / / 4. 1' l' i II 1 I I I LOT AREA \'7 I 1 J 24,274 SF �A� y�P� X I I I I � G. /0 / / Yd RIM=211.22 I 00434600006201 �� / I B RIM=h76.14 1 / IE 12" 1CP(W)=17 .24 I �T I II II I' z / / \ I ' / X �/ IC 17" '17nD/C1- 17'J 3A Cps 02 IE 172.24 (12" PVC IN, S) 1 sa I �� \ I I I I I o OST / l `N° YD RIM=215.57 00434600006203 w I I I 12 2 '7 I (CONTRACTOR TO WORK AND COORDINATE WITH UTILITY PROVIDER TO ' 9�s I / / 1 I I PTO of / / j • l N - BRACE POLE DURING CONSTRUCTION) I I I W rn SCALE: 1 - 20 N 79'50'33' W 3.94 /\ I L I POST a /' I I 1 / `` z HOUSE 20 10 0 20 40 FOUivu REBAR �' CB#1 S / #9500 ) I I I / X W/ILLEGIBLE CAP 0.6'(N) Q A- TYPE-2 48" W/ SOLID LID �T \. ` I I // / & 0.2'(W) OF CORNER YD r O T RIM=217.16 ° FOUND 1 RIM=215.05 PIPE 1.0'(N) & \ I I�E I POA / / A \ \ / t / 0.3'(W) OF CORNER \, c3 \ 1 I POST 0 9510 190TH PL. SW. I Ip I I I I O a I \ \ 6.4' / (SHALL HAVE ACCESS TO PROPERTY AT ALL TIMES DURING CONSTRUCTION) y� �v 9� / 00434600008002i� I I I I I \\ ° RESTORE WALLS TO IXISTING - CONDITION AFTER PIPE INSTALLATION. \y 1 LO I I r\ CN I \ I --------- ( l j l YD RIM=213.98 /� S / _ 4 N j I I F AR�_-- / - I I I W/ILL P� , i / i / I • / / / / LL, I I _ __----------- 0.1'N / 1 OF �, �1 �I ,I - �\ \� I \I 1 1 I I 1 1 / / / FOUND REBAR W/CAP I\ o T \ \ \ I I I STAMPED '22969" 0.1 '(N) °' I 1 I \ I I l I / I & 0 1 '(W) OF CORNER CLEAN OUT TABLE CO # RIM CO I.E. AS -BUILT RIM AS -BUILT I.E. 1 (FOOTING) 211 207 2 247 245 3 247 244.75 4 (FOOTING) 213 208.9 5 (FOOTING) 214 211 6 (FOOTING) 216.5 209 7 251 248 ACCEPTABLE TIGHTLINE MATERIAL: SDR 35 SCH 40 N-12 F810 HANCOR FOUND REBAR W/CAP STAMPED \\ \ \ \ a I I I "17679" 0.4'(N) OF CORNER \ \ I _-1 \ `,dG 03 � ,�,`� FENCE COR. 0.2'(E) OF \ X s'� r \ CB#2 t a Q ° 1 / PRPERTY LINE -------------------� - TYPE 2-4870 W/ SOLID LID IV 89.1523" W 50.00' "'FOOTING\� DRAIN (TYP.) i i a s CO#2 a Q ° a I CB#6 00434600006103 SEE DETAIL B 1 ` j/ ' %I O1 CI SSC011, /� I P _ 1 STA: 33+42.74, 0.02 L ROOF _ \ _ _ RIM. 211.75 IE. 208.30 (6 PVC OUT, S) DRAIN' (TYP.) I CAP STAMPED - ';ORNER FOUND REBAR W/CAP I I I 4" SS STUB FOR LOT A C C STAMPED '22969" 0.2'(W) I I i I • CO#5 IE 208.50 C3.1 OBTAIN APPROVAL P OF CORNER. FENCE III CO#4 12. ' FOR ANY WORK TO 0.4'(W) AT CORNER OCCUR ON ° I I j l I I 2 A A ADJACENT PARCEL A III I RETAINING C3.1 °a ° a PROPERTIES. PROPOSED BLOCK WALL I I\ I \ I I WALL (TYP.) a I � \ \• I I � oa a° I FOUND REBAR W/CAP I I •\ \ LOT B ° a °Q A CESS STAMPED 22688" 0.4' S I I EASEMEI (PRIVATE) p \ \ o AFN-1 n & 0.1 '(W) OF CORNER. I 102 \ \ C-)CO#3 DETENTION VAULT FENCE 0.1 '(W) AT CORNER I 1 \ N (95' x 16' x 8 CITY OF EDMONDS A\ uj o I \ ® o SSCO#2, 24" ACCESS RISER TYP. SP #S-44-79 \ I CS STA: 32+53.41, ( ) 0.01 L a VOL, 7659, PGS. 7928-7936 \ II v> RIM: 213.00 6' PROPOSED � / � 19120 94TH AVE W (PRIVATE)30' EXISTING p a IE.• 206.50 (61PVC In N) DRAINAGE EASEMENT 1 IE.' 206.40 INC6"OUT, S - I- l 00434600006101 UTILITY EASEMENT JR ( ) z (PRIVATE) FOUND REBAf� I W W/CAP STAMPED I 2 rn o 22969" 0.2'(N) / I SEWER CLEANOUT 00 a- �/ OF CORNER I CS. (TYP.) CB#3 TYPE 2-4870 W/ SOLID LID . REBAR W/CAr TAMPED '22969" 0.3'(W) I I & 0.4'(N) OF CORNER.I l� FENCE 0.2'(W) / SSCO#3, STA: 32+04.67, 0.00'� RIM: 218.50 IE.• 205.45 (61PVC In N) PARCEL e IE.• 205.35 (8"PVC OUT, SW) o TRENCH BACKFILL AROUND NEW SEWER MAIN C6 SHALL MEET 95%' COMPACTION (AND BE TESTED). THE MAIN & LATERALS SHALL BE TV'D & PROVIDED TO THE CITY AFTER BACKFILL & PRIOR TO FINAL INSPECTION. a (PRIVATE)ACCL__ A C1,1-9nonn F'JAn 17C. 45LF 8" PVC S=0.0066 FT/FT Z LIA \ (PUBLIC) EASEMENT RUNS ALONG SOUTHERN PROPERTY LINE AND IS FULLY ENCOMPASSED BY AFN-202006240176 I 11 SSMH 1 RIM:209.03 I h IE 203.95 (IN, E) I II PROJECT OWNER IS z 1 II \\ \ o \ \� \ \ I I 11 11 11 II / I 1\ 11 I If RESPONSIBLE TO RESTORE DISTURBED AREAS PER THE I I I \ \ 1 I + RECORDED PRIVATE I I I \ \ g EASEMENT. I\ \ \ N\ I j I DO; \\\ \\\ \\ o \\ LOT A ° �► 0 4' SS STUB FOR LOT B b z REDUCED FIRE IE: 206.70 489'1523" FOOTING DRAIN Q TURN AROUND. N " W 137.00' 12'x18' 21+00 6" SIDE CB#4 SEWER o WQ FILTER CONTROL 41SER v IE: 238.61 (12" OUT, W) 'a io �O 4' SS STUB a° FOR LOT C IE. 206.00 LOT C CB#5 P 4 6' VERT. SEP. rc. onzng; /nlrr c) 0 CROSSING 'a NEW IE. 205.05 (8" IN, NE) i �� I\ 11 1 I 144LF 8- PVC S=0.2802 FT/FT NOTE: RECHANNEL MANHOLE ENSURE LADDER IS NOT - - _ - - - - _ - )0 FENCE I I I I I I \+_00 BLOCKING INCOMING PIPES I PER CITY STANDARD GU-421. FOUND REBAR W/ILLEGIBLE CAP N 89 650.0, 1) 649.90'(M) N 8 15, W 137.00' NEW HOLE DRILLED INTO 0.7'(W) & 0.1 '(S) OF CORNER. N 89'. 11 z5 W 649.91 '(M) (MON 'TO MON) I I l 7 17221�- 1 EXISTING STRUCTURE. FENCE COR. 0.3'(N) & I , I PASIS OF PEA' I / FOUND REBAR W CAPMINIMUM 8' BETWEEN IE'S 0.4'(W) OF CORNER. I IEXG SIDE SEWER TO EXG 6" CONC. I5n ' 19204 TO BE CONNECTED SS LINE TO REPLACE CLEANOUT TO REPLACED SIDE SEWER BE REPLACED FIELD VERIFY LOCATION OF SIDE SEWERS & WITH MANHOLE 11 CLEANOUTS 0 EDGE OF EASEMENT FOR ALL EX. END FENCE 0.05'(N) RIM: 253.51 CONNECTIONS TO REPLACED SEWER MAIN. REPLACE OF PROPERTY LINE IE.• 245.51 (8- PVC OUT, W) OR ADD CLEANOUTS AS REQUIRED. 6' CLEANOUT IE: 245.61 (6" PVC IN, NE) W/12' CAST IRON LAMPHOLE COVER W/PICKHOLEE, 19204 94TH AVE W IE. 245.61 (6- PVC IN, SE) ORNER 1/2' HEX BOLTS 0 CONCRETE COLLAR) (TO REINAIN) SSCO#6 RIM: 254.00 1 1 IE 249.81 -r )UND REBAR W/CAP SHED H (TO �N� STAMPED '22969" 0_2'(N� 5;X10' GRATE RECORDED PRIOR TO FINAL INSPECTION I IN CONJUNCTION W/AS-BUILTS 3' HORIZONTAL SEPARATION BETWEEN WATER I -S ERVICE LINE AND DRY IITIIITIF4 (TYP ) i PROPOSED 6- SIDE SEWER TO 19120 02% DRY UTILITY TRENCH v (POWER, GAS, j _ PHONE, ETC) PROPOSED PRIVATE EASEMENTS SHALL BE RECORDED PRIOR TO FINAL APPROVAL. 1' WIDTH VARIES MINI (SEE NOTE 5 & 6) HMA CLASS 1/2" PG 58H-22 (SEE NOTE 2) 2.� CURBING (SEE NOTE 7) 29,E CRUSHED SURFACE BASE COURSE PER WSDOT STD SPEC 9-03.9(3) (SEE NOTE 1) 1. C BC DEPTH SHALL BE A MINIMUM OF 6" THICK. 2. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. 3. FINAL PAVEMENT JOINTS SHALL BE NEATLY SAW CUT AND UNIFORMLY SEALED PER WSDOT STANDARD SPECIFICATIONS 5-04.3(4)A. 4. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 5. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE TABLE OF STREET STANDARDS FOR PRIVATE EASEMENT AND PAVEMENT WIDTHS. 6. FIRE DEPARTMENT MAY REQUIRE ACCESS TO BE WIDER THAN REQUIRED IN EDMONDS COMMUNITY DEVELOPMENT CODE IF IT IS DETERMINED FIRE FIGHTING OR RESCUE OPERATIONS ARE HAMPERED. 7. 6" CONCRETE EXTRUDED CURB PER COE STD DETAIL TR-522 OR 18" ASPHALT THICKENED EDGE PER COE STD DETAIL TR-533 REQUIRED. REVISION DATE CITY OF EDMONDS PRIVATE STREET APRIL 2021 (1 -4 LOTS) T PUBLIC WORKS STANDARD DEPARTMENT DETAIL est. 189cj APPROVED BY: R. ENGLISH TR-510 1 PRIVATE STREET ('3 0 NTS STD DTL. TR-510 15' I I I I EX R/ a 1 \I I FOUND REBAR W/CAP 3 I STAMPED '22969" 0.1'(N) & .01 '(E) OF CORNER. ` FENCE 1.7'(W) AT CORNER \\ I CB RIM=265.01 I I IE 12" CPP(N)=260.56 \ X /l I IE 12" CMP(W)=262.76 a / CB RIM=265.84 IE 12" CMP(E)=263.64 \ Al IE 12" CPP(S)=264.09 (PRIVATE) I PROPOSED WATER LINE EASEMENT TO u' PROPOSED 1.5" BE RECORDED \ \ o� PROPOSED 1" POLY WATER PRIOR TO FINAL 7 11 I WATER METER (TYP.) SERVICE LINE TO INSPECTION IN BE INSTALLED WITH CONJUNCTION WITH TRACER WIRE (TYP.) AS-BUILTS \ EX F.H. / P HL L;ESS & UTILITY DRY UTILITY TRENCH J PPROPOSED COPPER WATER RIM:256.29 \ B EASEMENT UNDER THICKENED EDGE -- / SERVICE LINE (TYR) IF' 948.29 EDGE OF EASEMENT AFN-1926R81 nc CO, / � F 4ON. - W/Y tfKHJS UISK & 'X': 30 00 i DOWN 0.6'. HELD FOR 2% ' BEARING 1 +00 y� SIT 2-27-20. ° O VI EQ 3-1.5" WATER I' / `" 19204 DHI FWAY ° SERVICE LINES '' ° COIVR 0+00 I FOUND 1-1/2" IRON PIPE PROPOSED 1" WATER IE 12" RCP=266.86 SERVCE LINE (TYP.) 19 0 DRIVEWAY . G SIDE SEWER TO 19210 ESS & UTILITY EASEMENT A. ° IE 12" RCP=267.17 TO REPLACED SIDE SEWER B-1926982 • a 4 ETEI / (FIELD VERIFY LOCATION OF SIDE SEWERS & MAINTAIN CONTINOUS #19210 METERA FOUND TACK I LEAD \ CLEANOUTS 0 EDGE OF EASEMENT FOR ALL EX ESS TO # 19210 & # 19204) & SERVICE 4/WASHER STAMPED CONNECTIONS TO REPLACED SEWER MAIN. REPLACE w (TO REMAIN . ,'22969" 0.2'(N) OF CORNER IOT AREA \\ 14,110 SF \ \ I 0043V600006106 \ I I BE ABANDONED AND NEW CONNECTION TO BE PROVIDED TO LOT D) LOT D TSSCO#5 RIM: 255.50 IE. 248.61 3 J,-4SS STUB FOR LOT D 1 ►E. 248.63 C31 \\ COURSE PER WSDOT STD SPEC 9-03.9(3) (SEE NOTE 1) I.. CSBC DEPTH SHALL BE A MINIMUM OF 6' THICK. AND ACHIEVE 95% MINIMUM COMPATION PER ASTM D 1557. REVISION DATE CITY OF EDMONDS APRIL 2021 ASPHALT THICKENED EDGE r�` PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fsl- �g9� APPROVED BY: R. ENGLISH TR-523 2 ASPHALT THICKENED EDGE C3. NOT TO SCALE FINAL ROW RESTORATION LIMITS TO BE DETERMINED BY ENGINEERING INSPECTOR. Restoration of utility patches as follows: i.Utility patches with less than 20-feet of separation shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. ii. All final restoration within the right-of-way shall be completed by the contractor not the City of Edmonds. NOTES: 1. A PRECON WILL BE SCHEDULED PRIOR TO COMMENCING ANY WORK ON THE PROJECT. ALL APPLICABLE UTILITY PROVIDERS WILL BE PRESENT ALONG WITH THE CITY. LOCATE WILL BE CALLED IN PRIOR TO MEETING FOR ALL PARTIES TO ENSURE EACH UTILITY HAS THE PROPER REQUIRED SEPARATION. 2. ALL UTILITY PIPES SHALL BE INSTALLED PER CITY OF EDMONDS STANDARDS FOR BACKFILL, ANCHORING, MIN. SLOPE, ETC. AS-BUILTS WILL BE PROVIDED AFTER INSTALLATION. J. ALL PROPOSED PRIVATE EASEMENTS SHALL BE RECORDED PRIOR TO FINAL APPROVAL AND IN CONJUNCTION WITH UTILITY AS -BUILT DOCUMENTS TO ENSURE ACCURACY. NOTES: 1. ALL CB'S ARE TYPE-1 UNLESS OTHERWISE NOTED. 2. IF THE RIM TO INVERT ELEVATION EXCEEDS 5-FEET, THEN A TYPE-2 MANHOLE IS REQUIRED. 3. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 4. A MINIMUM OF 3' HORIZONTAL AND 1' VERTICAL SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES AND SEWER, WATER, AND STORM AND 5' FROM ANY CITY MAIN LINES. 5. EACH HOME WILL BE EQUIPPED WITH A 130 SPRINKLER SYSTEM. 6. COORDINATE WORK IN 190TH PL SW ROW WITH THE P.U.D. 7. A MINIMUM OF 2' OF COVER IS REQUIRED FOR ALL PIPES LOCATED UNDER DRIVEABLE SURFACES AND 1' OF COVER UNDER LANDSCAPE AREAS. OR ADD CLEANOUTS AS REQUIRED. 6 CLEANOUT SSMH RIM=269.76 RESTORATION LIMITS TO BE DETERMINED W/12' CAST IRON LAMPHOLE COVER W/PICKHOLE. 10 94TH AVE W BY CITY ENGINEERING INSPECTOR 1/2' HEX BOLTS A CONCRETE COLLAR.) IE 8" PVC(S)=261.86 Ir St" DI/n/Ct-oC.1 f7L: RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT UTILITY CONFLICTNOTE:• Know what's below. CAUTION. Call before you dig. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 250 240 230 220 210 200 190 170 1 _j CL m o J EX STING GRADE c o Ln J v- N 1' MIN. C ER N 103LF 8" PVC 0 27.597. N Q J CL Q 0 99' PIPE ANCHOR EVERY 20' 1 N ON PIPES WITH A SLOPE C.3.I + OF 20% OR MORE N r D p0 ®6 tj P QJ F8 CBI WQ FILTER STA:20+49.28, 0.01 ' R RIM:251.22 o IE 235.25 (12" IN, E) IE: 232.92 (8" OUT, znzc� CB 3 TYPE 2-48"0 W SOLID LID STA:21 +52.47, 0.00' RIM:211.01 I : 204.50 (8" IN, E) CB 2 TYPE 2-48"0 W SOLID LID I : 204.50 (8" OUT, N) STA:22+52.97, 0.00' RIM:208.65 I : 198.50 (8" IN, S) I : 198.50 8 OUT, N C3.0 55LF 8" PVC 27.91% CB#1, TYPE-2 48" W/ SOLID LID FFORFOOTING STA:24+06.50, o.00' CONNECTIONS. n RIM:192.33 IE 187.59 (8" IN, S) IE 1187.59 (8" OUT, NW) PIPE ANCHOR EVERY 20' ON PIPES WITH A SLOPE STORMLINEPROTILE OF 20Z OR MORE SCALE: 1 "=40' HORIZ, 1 "=4' VERT DESIGN SP ED = 20 MPH EX. CB RIM=176.14 E 172.24 (12" RCP, W) IE 172.34 (12" RCP, E) IE 172.24 (12" PVC IN, 1_' o) N d Lf) cf d °O Qo Ln o o L(. L op p r o N p �O N N o N N N N O �- N N `- N N N ',I- N N d- Ln N N 250 270 240 260 230 220 250 210 200 190 170 �r N N 25+00 24+50 24+00 23+50 23+00 22+50 22+00 21+50 21+00 20+50 20+00 240 230 225 00 N NE 114, SEC. 13, T. 27 N., R.03 E., W.M. .SNnunAjrgT-T rnTTNTV WWA.I�uTNFOMIV PVI STA: 0+73.70 PVI ELEV. • 268.12 K. 4.71 LVC: 55.00 N N f f N O , U 1.71 %-2.0 � ULd 0.857- 6.63% PVI TA: 1 +59.29 PVI ELEV. 253.17 K: 3.76 VC: 60.00 N d N N LO CIO co LO m �w W PVI S A: 2+56.56 PVI ELEV. 251.68 35.21 L C: 75.00 C) N C) o� N I N I N W W EXISTING GRA E U U @ CIL OF RD m PROPOSED GRADE > W m ® CIL OF ROAD Lv ALL STORM •52q STRUCTURES TO BE FLUSH WITH FINISHED GRADE l 8" SEWER MAIN -� L �36 1, WATER SERVICE INES �a EL: 246.11 11LF 12" PVC @ 12.361-. CB 5 TYPE 2 48" STA:2+ 11.29, . 67' L RIM:252.18 IE: 246.31 (12- OUT, N) CB 6 STA:3+51.39, 1.93' L RIM:248.17 IE.• 243.85 (12" OUT, S) N N N� N LO N� N� N N N N N N N N N 35LF 12" PVC ®1.49% DETENTION VAULT (95' x 16' x 8 E_: 238.11 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 DRIVEAISLE PROFILE SCALE: 1 "=10' HORIZ, 1 "=3' VERT DESIGN SPEED = 20 MPH r UTILITYCONTLICTNOTE.' Know what's below. CAUTION. Call before you dig. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 270 260 y B• M PPE JOINT ' -. •'?; . t. NOTE: Flri Y.PL PIPE MUST BE 00 T SLIDE INSEE A 4-FT SEOTION 6 PIPE. ONE SM DIAMETER LMGEF. M SI PIPE C402 DETAII PPE TRENCN - MN NET DONORETE BLDC✓<-_ '" ,., r 7 IN,,,UMSTURISM 5011. MIN SECTION A -A R 1 PIPE ANCHOR ASSEMBLY C3.3 & 3 NOT TO SCALE 20' ACCESS AND UTILITY EASEMENT 13.5' 2' 6' 18" THICKENED EDGE 27 PROPOSED WALL 6' L4" HMA CLASS 112" ASPHALT (2 LIFTS REQUIRED) ROADWAY AND 6" COMPACTED DEPTH CRUSHED ROADWAY BASE SURFACING BASE COURSE SHALL BE LOCATED 2 DRIVE AISLE (SECTION A -A) U N D E R TH E NOT TO SCALE PRIVATE STREET PER TR-510 THICKENED EDGE. C3.0 250 20' ACCESS AND UTILITY EASEMENT I 240 230 225 4+UU VARIES 18" THICKENED EDGE VARIES VARIES 2.0% /77/7 (2 LIFTS REQUIRED) 6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE 3 DRIVE AISLE (SECTIONS B) NOT TO SCALE PRIVATE STREET PER TR-510 C3.0 20' ACCESS AND UTILITY EASEMENT 12' 2' 6' 6' 18" THICKENED EDGE PROPOSED WALL 2% 2% �"-17M_A CLASS 1/2 (2 LIFTS REQUIRED) 6 COMPACTED DEPTH CRUSHED SURFACING BASE COURSE 4 DRIVE AISLE (SECTION C-C) C3 NOT TO SCALE PRIVATE STREET PER TR-510 RES U 6 Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 5 x 10' r GRATE EL=251.27 11 EL=248.75(f) S) �O�O d v da a d d ' I �0000 " O O O O SCALE: 1" = 10, 0 5 10 LOCK WALL DETENTION SUMMARY CHART - DETENTION VAULT STORM VOLUME STORAGE REQUIREMENTS (CF) MAXIMUM RELEASE RATES (CFS) EVENT DEAD LIVE DESIGNED AS -BUILT RATE DESIGNED AS -BUILT 2-YEAR 776 5,096 5,096 0.03 0.01 50-YEAR 776 10,759 10,759 IF 0.07 0.05 2 UTILITY CONTLICTNOTE • Know what's below. Call before you dig. CAUTION,• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. Z_ X 24" ACCESS g RISER (TYP.) N NE 114, SEC. 13, T* 27 N*, R.03 E, W.M. SNOHOMISH COUNTY, WASHINGTON EL�=248.11 I �I 12" INLET 0 0 0 95' IE=244.95 ---------- Q 50 YR. EL=245_61 - - - - - 000 7>0 0- - - - - - - - - - - - - - - - - - - - - - - - - - - - -2YR. EL=241.90----- 0� - - - - PIPE O o SUPPORT o °p (2 REQUIRED) 000 -O 0 o FLOOR GRATE W/2'x2' 0o (1Nx1/4AGALVANIIZCCESS DR - 0 o EL=238.61 METAL BARS) C op--------------------------r----------� - - W 0 O U U Q 24" ACCESS z RISER (TYP.) - EL: 248.11 EL=248.11LL I I 1 1 � I I -III 1-h1-1 t EL: 247.11 d m i EL: 246.11= a 16' l a a . . III I I ORIFICE #3 = 1 " DIA. 12" INLET e . - EL=245.41 -I --IE=244.95 - - - - a - ORIFICE #2 = 0.5" DIA. 4- EL=241.84 °------- - a° 12" INLET IE=243.32 - 1270 INLET _ EL=243.32 EL=238.61 a _ 1270 OUTLET - - - - - EL_238.61 EL=238.61 III �I = 7 00 0 *DEAD o ' . WIRE MESH _ 57STORAGE EL: 237.31 --i g . d _ II III EL: 237.71 - INSIDE CORNER EL= 238.11 FLOW CONTROL 4 5" STRUCTURE - � NON -SHRINK GROUT PVC PIPE- 1'-0* MAX • CONTROL DEVICE EL* ASSEMBLY TO BE COUPLING PVC PIPE REMOVABLE FROM (OPTIONAL) STUB* I INSIDE THE FCS I PVC PIPE - IF" SET SCREW TO 7 PREVENT ROTATION J r JL T INVERT'* TEE* 2 SPOOL* GASKET (TYP) .-4 PVC PIPE I ELBOW* PVC ADAPTER* W/ CROSS* o DOUBLE CASKET I O AND ADHESIVE BONDED SAND FINISH ON EXTERIOR. MIN 7" LONG DRILLED ORIFICE CAULK SPACE BETWEEN IN PVC INSIDE PVC ADAPTER AND PIPE STUB CONNECTION & CAP PLUG CONTROL DEVICE ORIFICE DIAMETER*DRILLED DETAIL A ORIFICE CONNECTION AND 0 LADDER OR HAND HOLDS - DIA* CONTROL DEVICE POLYPROPYLENE PVC INSIDE (SEE DETAIL A) 1 CAP PLUG* OUTLET PIPE -�- \ - ALLOWABLE OUTLET LOCATION CINCH ANCHOR (180' to 315') WIRE ROPE CLIP (SS) FINISHED GRADE CATCH BASIN TYPE II DEFORMED V-NOTCH WEIR AS NEEDED*' PER 00 STD DTL 3 8 STEEL SD-300 / OVERFLOW E" MIN ROD (SS OR + ALUMINUM) ADDITIONAL ORIFICE LENGTH TO FIT SUPPORT (2 REQ'D) AS NEEDED* INVERT* 1'-0" MIN PVC PIPE & - 1'-6" MAX CROSS FLOW CONTROL STRUCTURE CONTROL DEVICE 6I SEE DETAIL A it DETENTION PIPE PIPE SUPPORT (LENGTH, DIAMETER, DETAIL B DIAMETER* MATERIAL TYPE)* FLOW CONTROL STRUCTURE SHOWN W/ TYPE 2 CATCH BASIN (DETAILS A & B SHALL APPLY TO ALL DESIGNS NOTES: WHERE A SHEAR GATE WOULD OTHERWISE APPLY) * SPECIFIC DESIGN INFORMATION AS INDICATED ON APPROVED CONSTRUCTION DRAWINGS. INVERT OF DETENTION PIPE IN STRUCTURE SHALL BE EQUAL TO OR HIGHER THAN THE INVERT OF THE OUTLET PIPE. PRIVATELY -OWNED CONTROL STRUCTURES SHALL NOT BE PLACED IN CITY RIGHT-OF-WAY. _ REVISION DATE CITY OF EDMONDS FLOW CONTROL JANUARY 2018 STRUCTURE PUBLIC WORKS (FCS) STANDARD DEPARTMENT DETAIL FSt )g9� APPROVED BY: R. ENGLISH SD-301 I V-0 4 TLOW CONTROL STRUCTURE C3.2 N.T.S. SD-301 �6-1/2" MIN M� LADDER TO HANG FROM MH STEP I IT o WALL J SUPPORT (TYP) ,{ 5.5" I . .'d' d PREFABRICATED LADDER r 9-3/8" FOR BLOCK OR BRICK MH SECTION i 9-1/2" FOR PRECAST MH - _ - SECTION (4" FOR 7" FOR MODIFIED STEP FOR MODIFIED PRECAST MH SECTION STEP) STEP NOTES: 1" MIN POLYPROPYLENE 1. LADDER MAY BE INSTALLED IN ALL - PLASTIC STEP CATCH BASINS AND MANHOLES WHEN DEPTH OF STRUCTURE FROM - - TOP OF FRAME TO LOWEST FLOWUNE EXCEEDS FOUR(4) FEET. 2. DIMENSIONS FOR THE MH LADDER AND STEP ARE MINIMUM REQUIREMENTS ONLY. +� 3. STEPS AND HANDHOLDS SHALL BE a INSTALLED AT 1'-0" ON CENTER SPACING. WHEN THE DISTANCE FROM THE HIGHEST STEP OR o HANDHOLD AT THE TOP OF THE MH FRAME EXCEEDS 1'-0" AND ANOTHER STEP OR HANDHOLD CANNOT BE INSTALLED BECAUSE OF THE LOCATION OF THE MH FRAME, A HANDHOLD SHALL BE /4.., INSTALLED BETWEEN THE TOP 2 LAYERS OF BRICK OR COLLAR. 4. IF BOTH STEPS AND LADDER ARE REQUIRED IN ANY STRUCTURE, THEY SHALL BE FROM THE SAME MANUFACTURER. 5. STEPS AND LADDER SHALL BE POLYPROPYLENE AND CONFORM TO ASTM D4101 WITH 1/2- ASTM A615 GRADE 60 STEEL REINFORCING BAR. LANE P-13938, M.A.PS2-PF, OR EQUAL. 6. FASTEN LADDER TO FLOOR AND WALL SUPPORTS WITH 1-1/2" x 3-3/4" ANCHORS. ANCHORS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. REVISION DATE CITY OF EDMONDS JANUARY 2018 STEP AND LADDER DETAIL PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 1B9'3 APPROVED BY: R. ENGLISH G U - 423 7 STEP AND LADDER DETAILR C3.2 N.T.S. GU-423 i5 C. d IE. 237.71� F.R.0.P RISER PVC (12-) ORIFICE #1: 0.5' 1 DETNTION VA ULT SECTION X-X @ 238.61 - 12" C3.2 NOT TO SCALE * THE PROPOSED DEAD STORAGE WILL PROVIDE AN AVERAGE DEPTH OF GREATHER THAN 0.5 FEET. standard type 2-60" diam. frame locking lid CB concrete top slab {marked `DRAIN' mounted over 2e diam. 36" CMP riser eccentric opening 6` PLAN NTS standard locking maintain 1" gap between M.H. frame &cover % bottom of slab & top of riser -provide pliable 36" gasket to exclude dirt i compacted pipe bedding _ riser, 36" diam. min., same material & gage as M.H. steps 127 O.C. - tank welded or fused to tank 24" weld or bolt max detention tank standard M.H. steps SECTION NTS Notes: 1. Use adjusting blocks as required to bring frame to grade. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). Figure 3.2.7 - Detention Tank Access Detail 3.2.3 Detention Vaults Detention vaults are box -shaped underground storage facilities typically constructed with reinforced concrete. A standard detention vault detail is shown in Figure 3.2.8. Control structure details are shown in Section 3.2.4. Design Criteria General. Typical design guidelines are as follows: Volume III- Hydrologic Analysis and Flow Control BMPs -December 2014 3-41 S 36"ACCESSRISER C3.2 RING AND COVER PER COE STD DTL GU-420 FOR CURB AND SPLASH LINE ONLY: FRAME AND GRATE PER COE STD 2"-6" CONCRETE RISERS DTL SD-320 SERIES USING NON -SHRINK GROUT, PROVIDE SMOOTH FINISH INSIDE AND OUT 8" MIN 18" MAX TOP SLAB - - - HANDHOLDS (2) i * . SEE COE STD DTL GU-423 20-X24" OR 24" DIA - - 6" MAX POLYPROPYLENE SAFETY STEP/LADDER 12" O.C. 1. 48", 54", 60", 72" OR 96'. (SEE NOTE 6 & 7) 01 - SAND COLLAR OR KOR-N-SEAL AROUND *dI PIPE o I I = I I 2-0. *_ MIN MAX PRECAST BASE AND 1 INTEGRAL RISER NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 8e FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. 7. STEP AND LADDER SHALL BE ORIENTED TO AVOID INSTALLATION ABOVE PIPE. REVISION DATE ~ CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2021 _ 48" 541960" PUBLIC WORKS 72", & 96" STANDARD DEPARTMENT DETAIL FSt. 189'3 APPROVED BY: R. ENGLISH SD-300 8 CA TCH BA SINTYPE 2 C3.2 N.T.S. SD-300 117 I V C .4 g 4" FOOTING DRAIN PER N _ - STRUCTURAL DRAWINGS TO CB #3 d 4 O. 0 d d 48" MIN DETENTION VA UL T SECTION DETAIL NOT TO SCALE 30"0 x 4" FRAME AND COVER INLET 1 -_ OUTLET 1 "F 4'01.D. 4'-10"0 O.D. TOP SLAB PLAN VIEW CARTRIDGES AND FLOW KIT NOT SHOWN CONTRACTOR TO GROUT TO FINISHED GRADE L----- J-- I I I I I - I I I I I I - I I I I I I I I I I I I I I I I I - I -------- FLOATA13LES I I BAFFLE I I __= I OUTLET FLOW RIM ELEV. 25122' TOP OF SYSTEM ELEV. 250.67' CONDITION: HS25 PER PROVIDED AND APPROVED STRUCTURALPLANS AND CALCULATIONS PROVIDED. DFM BURT FLOW I '� STUB INLET 1 INVERT - _ I ELEV. 235.25' I r-�- I INLET 1 PIPE 1-v OUTLET 1 INVERT 12"0 PVC ELEV. 232.92 L� (16"0 OPENING) O OUTSIDE BOTTOM fO FLOW KIT I ELEV. 232.27' -10"0 ELEVATION VIEW (THIS SHEET) SEEOUTUETDEfAIL 18" OUTLET RISER ASSEMBLY OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DETAIL A ORIFICE CONNECTION AND 0 LADDER OR HAND HOLDS - DIA* CONTROL DEVICE POLYPROPYLENE PVC INSIDE (SEE DETAIL A) 1 CAP PLUG* OUTLET PIPE -�- \ - ALLOWABLE OUTLET LOCATION CINCH ANCHOR (180' to 315') WIRE ROPE CLIP (SS) FINISHED GRADE CATCH BASIN TYPE II DEFORMED V-NOTCH WEIR AS NEEDED*' PER 00 STD DTL 3 8 STEEL SD-300 / OVERFLOW E" MIN ROD (SS OR + ALUMINUM) ADDITIONAL ORIFICE LENGTH TO FIT SUPPORT (2 REQ'D) AS NEEDED* INVERT* 1'-0" MIN PVC PIPE & - 1'-6" MAX CROSS FLOW CONTROL STRUCTURE CONTROL DEVICE 6I SEE DETAIL A it DETENTION PIPE PIPE SUPPORT (LENGTH, DIAMETER, DETAIL B DIAMETER* MATERIAL TYPE)* FLOW CONTROL STRUCTURE SHOWN W/ TYPE 2 CATCH BASIN (DETAILS A & B SHALL APPLY TO ALL DESIGNS NOTES: WHERE A SHEAR GATE WOULD OTHERWISE APPLY) * SPECIFIC DESIGN INFORMATION AS INDICATED ON APPROVED CONSTRUCTION DRAWINGS. INVERT OF DETENTION PIPE IN STRUCTURE SHALL BE EQUAL TO OR HIGHER THAN THE INVERT OF THE OUTLET PIPE. PRIVATELY -OWNED CONTROL STRUCTURES SHALL NOT BE PLACED IN CITY RIGHT-OF-WAY. _ REVISION DATE CITY OF EDMONDS FLOW CONTROL JANUARY 2018 STRUCTURE PUBLIC WORKS (FCS) STANDARD DEPARTMENT DETAIL FSt )g9� APPROVED BY: R. ENGLISH SD-301 I V-0 4 TLOW CONTROL STRUCTURE C3.2 N.T.S. SD-301 �6-1/2" MIN M� LADDER TO HANG FROM MH STEP I IT o WALL J SUPPORT (TYP) ,{ 5.5" I . .'d' d PREFABRICATED LADDER r 9-3/8" FOR BLOCK OR BRICK MH SECTION i 9-1/2" FOR PRECAST MH - _ - SECTION (4" FOR 7" FOR MODIFIED STEP FOR MODIFIED PRECAST MH SECTION STEP) STEP NOTES: 1" MIN POLYPROPYLENE 1. LADDER MAY BE INSTALLED IN ALL - PLASTIC STEP CATCH BASINS AND MANHOLES WHEN DEPTH OF STRUCTURE FROM - - TOP OF FRAME TO LOWEST FLOWUNE EXCEEDS FOUR(4) FEET. 2. DIMENSIONS FOR THE MH LADDER AND STEP ARE MINIMUM REQUIREMENTS ONLY. +� 3. STEPS AND HANDHOLDS SHALL BE a INSTALLED AT 1'-0" ON CENTER SPACING. WHEN THE DISTANCE FROM THE HIGHEST STEP OR o HANDHOLD AT THE TOP OF THE MH FRAME EXCEEDS 1'-0" AND ANOTHER STEP OR HANDHOLD CANNOT BE INSTALLED BECAUSE OF THE LOCATION OF THE MH FRAME, A HANDHOLD SHALL BE /4.., INSTALLED BETWEEN THE TOP 2 LAYERS OF BRICK OR COLLAR. 4. IF BOTH STEPS AND LADDER ARE REQUIRED IN ANY STRUCTURE, THEY SHALL BE FROM THE SAME MANUFACTURER. 5. STEPS AND LADDER SHALL BE POLYPROPYLENE AND CONFORM TO ASTM D4101 WITH 1/2- ASTM A615 GRADE 60 STEEL REINFORCING BAR. LANE P-13938, M.A.PS2-PF, OR EQUAL. 6. FASTEN LADDER TO FLOOR AND WALL SUPPORTS WITH 1-1/2" x 3-3/4" ANCHORS. ANCHORS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. REVISION DATE CITY OF EDMONDS JANUARY 2018 STEP AND LADDER DETAIL PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 1B9'3 APPROVED BY: R. ENGLISH G U - 423 7 STEP AND LADDER DETAILR C3.2 N.T.S. GU-423 i5 C. d IE. 237.71� F.R.0.P RISER PVC (12-) ORIFICE #1: 0.5' 1 DETNTION VA ULT SECTION X-X @ 238.61 - 12" C3.2 NOT TO SCALE * THE PROPOSED DEAD STORAGE WILL PROVIDE AN AVERAGE DEPTH OF GREATHER THAN 0.5 FEET. standard type 2-60" diam. frame locking lid CB concrete top slab {marked `DRAIN' mounted over 2e diam. 36" CMP riser eccentric opening 6` PLAN NTS standard locking maintain 1" gap between M.H. frame &cover % bottom of slab & top of riser -provide pliable 36" gasket to exclude dirt i compacted pipe bedding _ riser, 36" diam. min., same material & gage as M.H. steps 127 O.C. - tank welded or fused to tank 24" weld or bolt max detention tank standard M.H. steps SECTION NTS Notes: 1. Use adjusting blocks as required to bring frame to grade. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). Figure 3.2.7 - Detention Tank Access Detail 3.2.3 Detention Vaults Detention vaults are box -shaped underground storage facilities typically constructed with reinforced concrete. A standard detention vault detail is shown in Figure 3.2.8. Control structure details are shown in Section 3.2.4. Design Criteria General. Typical design guidelines are as follows: Volume III- Hydrologic Analysis and Flow Control BMPs -December 2014 3-41 S 36"ACCESSRISER C3.2 RING AND COVER PER COE STD DTL GU-420 FOR CURB AND SPLASH LINE ONLY: FRAME AND GRATE PER COE STD 2"-6" CONCRETE RISERS DTL SD-320 SERIES USING NON -SHRINK GROUT, PROVIDE SMOOTH FINISH INSIDE AND OUT 8" MIN 18" MAX TOP SLAB - - - HANDHOLDS (2) i * . SEE COE STD DTL GU-423 20-X24" OR 24" DIA - - 6" MAX POLYPROPYLENE SAFETY STEP/LADDER 12" O.C. 1. 48", 54", 60", 72" OR 96'. (SEE NOTE 6 & 7) 01 - SAND COLLAR OR KOR-N-SEAL AROUND *dI PIPE o I I = I I 2-0. *_ MIN MAX PRECAST BASE AND 1 INTEGRAL RISER NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 8e FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. 7. STEP AND LADDER SHALL BE ORIENTED TO AVOID INSTALLATION ABOVE PIPE. REVISION DATE ~ CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2021 _ 48" 541960" PUBLIC WORKS 72", & 96" STANDARD DEPARTMENT DETAIL FSt. 189'3 APPROVED BY: R. ENGLISH SD-300 8 CA TCH BA SINTYPE 2 C3.2 N.T.S. SD-300 117 I V C .4 g 4" FOOTING DRAIN PER N _ - STRUCTURAL DRAWINGS TO CB #3 d 4 O. 0 d d 48" MIN DETENTION VA UL T SECTION DETAIL NOT TO SCALE 30"0 x 4" FRAME AND COVER INLET 1 -_ OUTLET 1 "F 4'01.D. 4'-10"0 O.D. TOP SLAB PLAN VIEW CARTRIDGES AND FLOW KIT NOT SHOWN CONTRACTOR TO GROUT TO FINISHED GRADE L----- J-- I I I I I - I I I I I I - I I I I I I I I I I I I I I I I I - I -------- FLOATA13LES I I BAFFLE I I __= I OUTLET FLOW RIM ELEV. 25122' TOP OF SYSTEM ELEV. 250.67' CONDITION: HS25 PER PROVIDED AND APPROVED STRUCTURALPLANS AND CALCULATIONS PROVIDED. DFM BURT FLOW I '� STUB INLET 1 INVERT - _ I ELEV. 235.25' I r-�- I INLET 1 PIPE 1-v OUTLET 1 INVERT 12"0 PVC ELEV. 232.92 L� (16"0 OPENING) O OUTSIDE BOTTOM fO FLOW KIT I ELEV. 232.27' -10"0 ELEVATION VIEW (THIS SHEET) SEEOUTUETDEfAIL 18" OUTLET RISER ASSEMBLY OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I V-0 4 TLOW CONTROL STRUCTURE C3.2 N.T.S. SD-301 �6-1/2" MIN M� LADDER TO HANG FROM MH STEP I IT o WALL J SUPPORT (TYP) ,{ 5.5" I . .'d' d PREFABRICATED LADDER r 9-3/8" FOR BLOCK OR BRICK MH SECTION i 9-1/2" FOR PRECAST MH - _ - SECTION (4" FOR 7" FOR MODIFIED STEP FOR MODIFIED PRECAST MH SECTION STEP) STEP NOTES: 1" MIN POLYPROPYLENE 1. LADDER MAY BE INSTALLED IN ALL - PLASTIC STEP CATCH BASINS AND MANHOLES WHEN DEPTH OF STRUCTURE FROM - - TOP OF FRAME TO LOWEST FLOWUNE EXCEEDS FOUR(4) FEET. 2. DIMENSIONS FOR THE MH LADDER AND STEP ARE MINIMUM REQUIREMENTS ONLY. +� 3. STEPS AND HANDHOLDS SHALL BE a INSTALLED AT 1'-0" ON CENTER SPACING. WHEN THE DISTANCE FROM THE HIGHEST STEP OR o HANDHOLD AT THE TOP OF THE MH FRAME EXCEEDS 1'-0" AND ANOTHER STEP OR HANDHOLD CANNOT BE INSTALLED BECAUSE OF THE LOCATION OF THE MH FRAME, A HANDHOLD SHALL BE /4.., INSTALLED BETWEEN THE TOP 2 LAYERS OF BRICK OR COLLAR. 4. IF BOTH STEPS AND LADDER ARE REQUIRED IN ANY STRUCTURE, THEY SHALL BE FROM THE SAME MANUFACTURER. 5. STEPS AND LADDER SHALL BE POLYPROPYLENE AND CONFORM TO ASTM D4101 WITH 1/2- ASTM A615 GRADE 60 STEEL REINFORCING BAR. LANE P-13938, M.A.PS2-PF, OR EQUAL. 6. FASTEN LADDER TO FLOOR AND WALL SUPPORTS WITH 1-1/2" x 3-3/4" ANCHORS. ANCHORS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. REVISION DATE CITY OF EDMONDS JANUARY 2018 STEP AND LADDER DETAIL PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 1B9'3 APPROVED BY: R. ENGLISH G U - 423 7 STEP AND LADDER DETAILR C3.2 N.T.S. GU-423 i5 C. d IE. 237.71� F.R.0.P RISER PVC (12-) ORIFICE #1: 0.5' 1 DETNTION VA ULT SECTION X-X @ 238.61 - 12" C3.2 NOT TO SCALE * THE PROPOSED DEAD STORAGE WILL PROVIDE AN AVERAGE DEPTH OF GREATHER THAN 0.5 FEET. standard type 2-60" diam. frame locking lid CB concrete top slab {marked `DRAIN' mounted over 2e diam. 36" CMP riser eccentric opening 6` PLAN NTS standard locking maintain 1" gap between M.H. frame &cover % bottom of slab & top of riser -provide pliable 36" gasket to exclude dirt i compacted pipe bedding _ riser, 36" diam. min., same material & gage as M.H. steps 127 O.C. - tank welded or fused to tank 24" weld or bolt max detention tank standard M.H. steps SECTION NTS Notes: 1. Use adjusting blocks as required to bring frame to grade. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). Figure 3.2.7 - Detention Tank Access Detail 3.2.3 Detention Vaults Detention vaults are box -shaped underground storage facilities typically constructed with reinforced concrete. A standard detention vault detail is shown in Figure 3.2.8. Control structure details are shown in Section 3.2.4. Design Criteria General. Typical design guidelines are as follows: Volume III- Hydrologic Analysis and Flow Control BMPs -December 2014 3-41 S 36"ACCESSRISER C3.2 RING AND COVER PER COE STD DTL GU-420 FOR CURB AND SPLASH LINE ONLY: FRAME AND GRATE PER COE STD 2"-6" CONCRETE RISERS DTL SD-320 SERIES USING NON -SHRINK GROUT, PROVIDE SMOOTH FINISH INSIDE AND OUT 8" MIN 18" MAX TOP SLAB - - - HANDHOLDS (2) i * . SEE COE STD DTL GU-423 20-X24" OR 24" DIA - - 6" MAX POLYPROPYLENE SAFETY STEP/LADDER 12" O.C. 1. 48", 54", 60", 72" OR 96'. (SEE NOTE 6 & 7) 01 - SAND COLLAR OR KOR-N-SEAL AROUND *dI PIPE o I I = I I 2-0. *_ MIN MAX PRECAST BASE AND 1 INTEGRAL RISER NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 8e FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. 7. STEP AND LADDER SHALL BE ORIENTED TO AVOID INSTALLATION ABOVE PIPE. REVISION DATE ~ CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2021 _ 48" 541960" PUBLIC WORKS 72", & 96" STANDARD DEPARTMENT DETAIL FSt. 189'3 APPROVED BY: R. ENGLISH SD-300 8 CA TCH BA SINTYPE 2 C3.2 N.T.S. SD-300 117 I V C .4 g 4" FOOTING DRAIN PER N _ - STRUCTURAL DRAWINGS TO CB #3 d 4 O. 0 d d 48" MIN DETENTION VA UL T SECTION DETAIL NOT TO SCALE 30"0 x 4" FRAME AND COVER INLET 1 -_ OUTLET 1 "F 4'01.D. 4'-10"0 O.D. TOP SLAB PLAN VIEW CARTRIDGES AND FLOW KIT NOT SHOWN CONTRACTOR TO GROUT TO FINISHED GRADE L----- J-- I I I I I - I I I I I I - I I I I I I I I I I I I I I I I I - I -------- FLOATA13LES I I BAFFLE I I __= I OUTLET FLOW RIM ELEV. 25122' TOP OF SYSTEM ELEV. 250.67' CONDITION: HS25 PER PROVIDED AND APPROVED STRUCTURALPLANS AND CALCULATIONS PROVIDED. DFM BURT FLOW I '� STUB INLET 1 INVERT - _ I ELEV. 235.25' I r-�- I INLET 1 PIPE 1-v OUTLET 1 INVERT 12"0 PVC ELEV. 232.92 L� (16"0 OPENING) O OUTSIDE BOTTOM fO FLOW KIT I ELEV. 232.27' -10"0 ELEVATION VIEW (THIS SHEET) SEEOUTUETDEfAIL 18" OUTLET RISER ASSEMBLY OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISION DATE CITY OF EDMONDS JANUARY 2018 STEP AND LADDER DETAIL PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 1B9'3 APPROVED BY: R. ENGLISH G U - 423 7 STEP AND LADDER DETAILR C3.2 N.T.S. GU-423 i5 C. d IE. 237.71� F.R.0.P RISER PVC (12-) ORIFICE #1: 0.5' 1 DETNTION VA ULT SECTION X-X @ 238.61 - 12" C3.2 NOT TO SCALE * THE PROPOSED DEAD STORAGE WILL PROVIDE AN AVERAGE DEPTH OF GREATHER THAN 0.5 FEET. standard type 2-60" diam. frame locking lid CB concrete top slab {marked `DRAIN' mounted over 2e diam. 36" CMP riser eccentric opening 6` PLAN NTS standard locking maintain 1" gap between M.H. frame &cover % bottom of slab & top of riser -provide pliable 36" gasket to exclude dirt i compacted pipe bedding _ riser, 36" diam. min., same material & gage as M.H. steps 127 O.C. - tank welded or fused to tank 24" weld or bolt max detention tank standard M.H. steps SECTION NTS Notes: 1. Use adjusting blocks as required to bring frame to grade. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). Figure 3.2.7 - Detention Tank Access Detail 3.2.3 Detention Vaults Detention vaults are box -shaped underground storage facilities typically constructed with reinforced concrete. A standard detention vault detail is shown in Figure 3.2.8. Control structure details are shown in Section 3.2.4. Design Criteria General. Typical design guidelines are as follows: Volume III- Hydrologic Analysis and Flow Control BMPs -December 2014 3-41 S 36"ACCESSRISER C3.2 RING AND COVER PER COE STD DTL GU-420 FOR CURB AND SPLASH LINE ONLY: FRAME AND GRATE PER COE STD 2"-6" CONCRETE RISERS DTL SD-320 SERIES USING NON -SHRINK GROUT, PROVIDE SMOOTH FINISH INSIDE AND OUT 8" MIN 18" MAX TOP SLAB - - - HANDHOLDS (2) i * . SEE COE STD DTL GU-423 20-X24" OR 24" DIA - - 6" MAX POLYPROPYLENE SAFETY STEP/LADDER 12" O.C. 1. 48", 54", 60", 72" OR 96'. (SEE NOTE 6 & 7) 01 - SAND COLLAR OR KOR-N-SEAL AROUND *dI PIPE o I I = I I 2-0. *_ MIN MAX PRECAST BASE AND 1 INTEGRAL RISER NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 8e FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. 7. STEP AND LADDER SHALL BE ORIENTED TO AVOID INSTALLATION ABOVE PIPE. REVISION DATE ~ CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2021 _ 48" 541960" PUBLIC WORKS 72", & 96" STANDARD DEPARTMENT DETAIL FSt. 189'3 APPROVED BY: R. ENGLISH SD-300 8 CA TCH BA SINTYPE 2 C3.2 N.T.S. SD-300 117 I V C .4 g 4" FOOTING DRAIN PER N _ - STRUCTURAL DRAWINGS TO CB #3 d 4 O. 0 d d 48" MIN DETENTION VA UL T SECTION DETAIL NOT TO SCALE 30"0 x 4" FRAME AND COVER INLET 1 -_ OUTLET 1 "F 4'01.D. 4'-10"0 O.D. TOP SLAB PLAN VIEW CARTRIDGES AND FLOW KIT NOT SHOWN CONTRACTOR TO GROUT TO FINISHED GRADE L----- J-- I I I I I - I I I I I I - I I I I I I I I I I I I I I I I I - I -------- FLOATA13LES I I BAFFLE I I __= I OUTLET FLOW RIM ELEV. 25122' TOP OF SYSTEM ELEV. 250.67' CONDITION: HS25 PER PROVIDED AND APPROVED STRUCTURALPLANS AND CALCULATIONS PROVIDED. DFM BURT FLOW I '� STUB INLET 1 INVERT - _ I ELEV. 235.25' I r-�- I INLET 1 PIPE 1-v OUTLET 1 INVERT 12"0 PVC ELEV. 232.92 L� (16"0 OPENING) O OUTSIDE BOTTOM fO FLOW KIT I ELEV. 232.27' -10"0 ELEVATION VIEW (THIS SHEET) SEEOUTUETDEfAIL 18" OUTLET RISER ASSEMBLY OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 8e FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. 7. STEP AND LADDER SHALL BE ORIENTED TO AVOID INSTALLATION ABOVE PIPE. REVISION DATE ~ CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2021 _ 48" 541960" PUBLIC WORKS 72", & 96" STANDARD DEPARTMENT DETAIL FSt. 189'3 APPROVED BY: R. ENGLISH SD-300 8 CA TCH BA SINTYPE 2 C3.2 N.T.S. SD-300 117 I V C .4 g 4" FOOTING DRAIN PER N _ - STRUCTURAL DRAWINGS TO CB #3 d 4 O. 0 d d 48" MIN DETENTION VA UL T SECTION DETAIL NOT TO SCALE 30"0 x 4" FRAME AND COVER INLET 1 -_ OUTLET 1 "F 4'01.D. 4'-10"0 O.D. TOP SLAB PLAN VIEW CARTRIDGES AND FLOW KIT NOT SHOWN CONTRACTOR TO GROUT TO FINISHED GRADE L----- J-- I I I I I - I I I I I I - I I I I I I I I I I I I I I I I I - I -------- FLOATA13LES I I BAFFLE I I __= I OUTLET FLOW RIM ELEV. 25122' TOP OF SYSTEM ELEV. 250.67' CONDITION: HS25 PER PROVIDED AND APPROVED STRUCTURALPLANS AND CALCULATIONS PROVIDED. DFM BURT FLOW I '� STUB INLET 1 INVERT - _ I ELEV. 235.25' I r-�- I INLET 1 PIPE 1-v OUTLET 1 INVERT 12"0 PVC ELEV. 232.92 L� (16"0 OPENING) O OUTSIDE BOTTOM fO FLOW KIT I ELEV. 232.27' -10"0 ELEVATION VIEW (THIS SHEET) SEEOUTUETDEfAIL 18" OUTLET RISER ASSEMBLY OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT OUTLET SUMP -RISER ND COLLAR OR BOOT ro STUB 8"O STUB MOLDED -IN CUT LINE (SEE INSTALLATION NOTE E) iOUT(BY CONTECH) FLOW BYPASS (SEE INSTALLATION 2" PVC NOTE G) SLIP PLUG SYSTEM ACTIVATION DISK INSTALLED HERE. SEE INSTALLATION INSTRUCTIONS. PLAN VIEW TOP SLAB NOT SHOWN FOR CLARITY SITE DESIGN DATA WATER QUALITY 0.014 CFS FLOW RATE PEAK FLOW RATE 0.11 CFS RETURN PERIOD OF 100 YRS PEAK FLOW FILTER MEDIA TYPE ZPG OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT OUTLET DETAIL (ILLUSTRATION ONLY) MATERIAL LIST (PROVIDED BY CONTECH) COUNT DESCRIPTION INSTALLED BY 1 18" ZPG CARTRIDGE CONTECH 3 7.5 GPM RESTRICTOR DISK (BLUE POLY DISK) CONTECH 2 2" PVC SLIP PLUG CONTECH 1 40A FLOWKIT CONTECH 1 SF ACTIVATION DISK CONTECH 1 18" OUTLET RISER ASSEMBLY CONTECH 16 STEPS, P10CTS, LANE LADDER, OR EQUIV. CONTECH 1 SEALANT FOR JOINTS CONTRACTOR 1 30"0 x 4" FRAME AND COVER, EJ#41600483, OR EQUIV. CONTRACTOR U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U0 O W O J t` EL v F- _ (n Uj LL m PERFORMANCE SPECIFICATION O FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH w L Lu SHALL BE 74NCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. - � F- SPECIFIC FLOW RATE SHALL BE 1 GPWSF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA -I Lu SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPWCF OF MEDIA (MAXIMUM). (n GENERALNOTES (n 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. O 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED O 1 SOLUTIONS LLC REPRESENTATIVE. w .ContechES.com 1-- 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS U) P 4. S S E OH O A I U 0-A A AI AYYY U BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS y T TO O I CI B I IE I I I 1G 2 7;qi INSTALLATION NOTES LU` 3 r lo$ A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE IIr n £ LL E@ I SPECIFIED BY ENGINEER OF RECORD. Z' 1 G B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. 2� A�^4�1 C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. FFE3i D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. W E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN are sc•, .. CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 122123 1/4" = V-0" F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. oEs ON.. - G. CONTRACTOR TO INSTALL SUPPLIED PLUG IN CONSTRUCTION FLOW BYPASS WHEN SYSTEM IS BROUGHT ON LINE (PRESSURE FIT ONLY, SKJ SKJ DO NOT GLUE). CHECKED. -ROVED. STRUCTURE WEIGHT sEc, APPROXIMATE HEAVIEST PICK = 7000 LBS. OF 5 PIECES CONTECH CUZ En E`- 0Q 15NCE No.: BASE SECTION SHIPPED WITH CARTRIDGES INSTALLED PROPOSAL LAYOUT 1A MAX FOOTPRINT =04'-10" DRAWING 57841452901 s"EEr_ 1 or 1 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3 STORMFILTER STANDARD DETAIL C3.2 N.T.S. 1 " MIN. GAP BETWEEN STRAPS I- 9 X 1 x 12 GA GALV. TRAPS TACK WELD TO VIRE MESH. ATTACH TRAINER TO CMP ;ROSS W/ #6xl" >HEET METAL SCREWS ? PER STRAP 6 x 9/16" OR " x 16 GA V. WIRE MESH TACK WELD WIRE MESH TO BOTTOM PLATE �A GALV. BOTTOM PLATE 6 WIRE MESH BASKET C3.2 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NE 114, SEC. 13, T. 27 N., R.03 E., W.M. SNOHOMISH COUNTY, WASHINGTON 260 250 240 230 220 210 200 PROPOSED GRADE 2 Y2.0 0 i EX. GRADE SSMH 1 STA:30+ RIM.253. IE.• 245. IE.• 245. IE.• 245. 144LF 8' PVC S=0.2802 FT/FT \ 45LF 8' PV S=0.0 66 FT/FT PIPE ANCHOR EVERY 20' 1 C3.1 CO CROSSING IE 209.46 STORM CROSSING IE 207.16 89( 6-- 8 Pu CO C �IE: 20. 0 NG 3=0 0201 . SSCO 1 149LF STA:33+42.74, 0.02' L RIM:211.75 6' PVC IE. 208.30 (61PVC OUT, S SSCO 2 STA:32+53.41, 0.01 ' L S=0.0195 FT/FT EX. SMH RIM:213.00 STA: 31 +59.19, 0.00' IE: 206.50 (61PVC IN, N,1 RIM: 209.03 IE. 206.40 (6'PVC OUT, ) SSCO 3 IE 203.95 IE: 203.85 (IN, E) (OUT, S) STA:32+04.67, 0.00' NEW IE: 205.05 (8' IN, NE) RIM.218.50 IE: 205.45 6 PVC IN, IE. 205.35 (81PVC OUT 0 o �W) a, �I °N° o co N N N 00 N N N N N N N N r j N N Cp U� N N 260 250 240 230 REPLACE CLEANOUT 4.82, 0.00' WITH MANHOLE %1 Ail 1 RIM: 253.51 Know what's below. i (8"PVC OUT, W) IE 245.51 (8' PVC OUT, W) Call before you dig. 1 (6' PVC IN, NE) IE: 245.61 (6' PVC IN, NE) 1 (6' PVC IN, SE) IE: 245.61 (6' PVC IN, SE) R E S U B UTILITY CONFLICT NOTE. 1 Apr 25 2024 CAUTION. CITY OF EDMONDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE DEVELOPMENT SERVICES LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES DEPARTMENT WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE CAD 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH 220 INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 210 200 LO LO N 33+75 33+50 33+00 32+50 32+00 31 +50 31 +00 30+50 30+00 SEWER LINE PROFILE SCALE: 1 "=30' HORIZ, 1 "=3' VERT DESIGN SPEED = 20 MPH NE 114, SEC. 13, T. 27 N., R.03 E., W.M. SNOHOMISH COUNTY, WASHINGTON \ I FOUND REBAR W/CAP STAMPED "17679" 0.4'(N) OF CORNER L----------------------------------- I - N 89.15'23" W 50.00' I -----------------------------------I I SEE DE. %'' I FOUND REBAR W/CAP I STAMPED '22969" 0.2'(W) I I OF CORNER. FENCE III • / I 0.4'(W) AT CORNER I I III / I I I II► I I I I �I► I PARCEL A I I I • ► I I \I FOUND REBAR W/CAP II I � •\ \ STAMPED '22688" 0.4'(S) I o \ I & 0.1 '(W) OF CORNER. I a \ \ o FENCE 0.1 '(W) AT CORNER I 1 \\ N I � F I CITY OF EDMONDS I \ \ SP #S-44-79 \I \ I VOL. 1659, PGS. 1928-1936 \ \ - - - - - - - - - - - - - - - - - / 1 30' EXISTING I \ UTILITY EASEMENT SEWER CLEANOUT l I � � - - - - - - - - - - (TIP.) ----- CE FOUND REBAR W/CAPj STAMPED '22969" 0.3'(W) l % & 0.4'(N) OF CORNER.I 1 FENCE 0.2'(W) AT C--"-- 1 I SSCO#3, I STA: 32+04.67, 0.00' n/ I RIM: 218.50 ' 1 IE. 205.45 (6-PVC In N) 1 PARCEL e IE: 205.35 (8'PVC OUT, SW) o 1 TRENCH BACKFILL AROUND NEW SEWER MAI coI SHALL MEET 95% COMPACTION (AND BE TESTED). , r T \ THE MAIN & LATERALS SHALL BE A D & I w w PROVIDED TO THE CITY AFTER BACKFILL & PRIOR 1 TO FINAL INSPECTION. I 2? 1 45LF 8' PVC S=0.0066 FT/FT I I z ~ I I EASGIVIGIVI lC UIVJ /iLVIVU JVUIIIGlCIV PROPERTY LINE AND IS FULLY I I ENCOMPASSED BY AFN-202006240176 I II I FOUND CASED CONC. MON. SSMH \ W/NAIL IN CONC. DOWN 0.9'. RIM:209.03 I I 0.75N OF PROJECTED SOUTH LINE OF LOT 82, SEAVIEW rF• qn3 45 (IN, F) I O ; TRACTS. PER SURVEY AFN 200911065002(R3) & �U' 201509045002(R4). NEW IE: 205.05 (8' IN, NE) POSITION HELD, VISITED 2-27-20. - - - - - - - SOUTH LINE LOT 82, SEAVIEW TRACTS N "a � •'q & % SSCO#1, + STA: 33+42.74, 0.02' L RIM: 211.75 IE. 208.30 (6"PVC OUT, S) 4' SS STUB FOR LOT A IE: 208.50 0 0 0 0 cn a 11 to J 00 "'-6' SIDE SEWER LOT A I LOT SSCO#2, STA: 32+53.41, 0.01 ' L RIM. 213.00 IE: 206.50 (6-PVC In N) IE 206.40 (61PVC OUT, S)- z �u w co o� CL 4' SS STUB Qr CL � FOR LOT B \ o z IE: 206.70 N 89.1523" W 137.00' 74' SS STUB FOR LOT C IE.• 206.00 ----------- �---------------------L-- --- --�1 I,. ►WOG _ I ILLEGIBLE CAP N o9'1523' W 650.00'(R1) 649.90"(MJI - NOTE: RECHANNEL MANHOLE; I I''--- N 89'11'25" •W 649.91' M MON •TO MON I 1 I ENSURE LADDER IS NOT �' 0.1'(S) OF CORNER. B cz�e�� Ir_ ) I I BLOCKING INCOMING PIPES _`NCE COR. 0.3'(N) & I I ASIS OF PLR CITY STANDARD GU-421 0.4'(W) OF CORNER. I I I EXG SIDE SEWER TO- Ic 19204 TO BE CONNECTED TO REPLACED SIDE SEWER (FIELD VERIFY LOCA77ON OF SIDE SEWERS & I CLEANOU71S ® EDGE OF EASE WENT FOR ALL EX I 1 CONNEC71ONS TO REPLACED SEWER MAIN. REPLACE I 1 OR ADD CLEANOUTS AS REQUIRED. 6' CLEANOUT 1 W/12' CAST IRON LAMPHOLE COVER W/PICKHOLE. I 1 1/2' HEX BOLTS ® CONCRETE COLLAR.) I 5' EASEMENT w #1964577 I I j 7' EASEMENT #196544 I I j PUBLIC I I 19209 OLYMPIC VIEW DR. LELSEMENTS I I ------------- ---- I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I 0o 19211 OLYMPIC VIEW OR. N 19213 OLYMPIC VIEW DR. o I j 10' EASEMENT CN z I z # 1964543 W I\ o I � / Iz I I � � I ------------III----------------------- - C S`� ------------i/ � � v V S I ss ss ss ss ss - :�� I I I I I I 19223 OLYMPIC VIEW DR. I I I I I I I � i I 21+00 °a ,,6 I I I I � I I al al a FENCE COR. 0.2'(E) OF I/PR PERTY\NE \ 00434600006103 P I \ II --I--- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -OUND REBAR W/CAP STAMPED 22969" 0.1 '(N) OF CORNER 1 I P 12. ' I I / I / I / a a 2 a ° LOT C J_' 6' PROPOSED DRAINAGE EASEMENT 144LF 8' PVC S=0.2802 FTi i, -o mom's ALI 1. 6' VERT. SEP-' ® CROSSING -btlU / N 8?• 15 " W, 137.0,0' FOI `RWC EXG 6" CONC. SS LINE TO BE REPLACED REPLA CLEANOUT / W MANHOLE #1 END FENCE 0.05'(N) RIM: 253.51 OF PROPERTY LINE IE. 2 .51 (8' PVC OUT, W) REFER TO TREE PROTECTION IE 45.61 (6' PVC IN, NE) NOTES FOR AIR EXCAVATION IE: 245.61 (6' PVC IN, SE) 192041N ARBORIST REPORT FOR TREE PROTECTION MEASURES. 19212 94TH AVE W. 'ER �a (TO REMAIN) BLOCK WALL 1 � - ACESS & UTILITY EASEMENT Ai N-1926981 I I � / I 19120 94TH AVE W FOUND % REBAIiI l / 00434600006101 I �c, W/CAP STAMPED I l "22969" 0.2'(N) OF I SSCO#6 I RIM. 254.00 IE. 249.81 \ \ SHED -"22 96(W/CAP \ (TO REMAIN) r"MPED 22» " """'� 1 YE) OF 1 ' N, I mac: cvy.ao PROPOSED SEWER EASEMENT TO BE RECORDED PRIOR TO FINAL INSPECTION IN CONJUNCTION W/AS-GUILTS PROPOSED 6' SIDE SEWER TO 19120 02% BE ABANDONED AND NEW NNECT70N TO BE PROVIDED TO LOT D) TSSCO#5 RIM: 255.50 IE. 248.61 �4- SS STUB FOR LOT D E. 248.63 M:256.29 \ : 248.' r-EDGE OF EASEMENT i i V.OT AREA \\ 1 I \�Wl 1 I i LOT D i 1 ACCESS & UTILITY \I \ EASEMENT] I AFN-1926R81 I SCALE: F' = 20' 20 10 0 20 40 FOUND REBAR W/CAP STAMPED '22969" 0.1'(N)\ & .01 '(E) OF CORNER. FENCE 1.7'(W) AT CORNER /� � Ala" FOUND RE / W CAP S7 22969" ' / �OF C( / 30+00 10 N 9204 6RI EWAY °• �.: a �a j a a.4 ae A d CqW ' n -EXG SIDE SEWER Tiff 19210 ACCESS & UTILITY EASEMENT 19 0 DRIVEWAY \ TO REPLACED SIDE SEWER AFN-1926982 .. a j °� (FIELD VERIFY LOCATION OF SIDE SEWERS & MAINTAIN CONTINOUS #19210 METER FOUND TACK 1 LEAD CLEANOUIS EDGE OF EASEMENT FOR ALL EX ESS TO 19210 & 119204) & SERVIC W/WASHER ST^ CONNECTIONS TO REPLACED SEWER MAIN. REPLACE # OR ADD CLEANOUTS AS REQUIRED. 6' CLEANOUT CID RE7bWN)Ii. : 2200 W/12' CAST IRON LAMPHOLE COVER W/PICKHOLE 10 94TH AVE W 1/2' HE)( BOLTS ® CONCRETE COLLAR.) I I I I I I I I i i i i I I �s I I i RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C Know what's below. Call before you dig. UTILITY CONFLICT NOTE. CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. NE 114, SEC. 13, T. 27 N., R.03 E., W.M. SNOHOMISH COUNTY, WASHINGTON m :C / � � 2 . The City's Public Works Operations and Maintenance � _ — N \ Department to fabricate fire/aid address sign. The '� m contractor/owner shall contact the Engineering Division by email at o U/y p I engineeringpermits@edmondswa.gov 2-weeks in advance of the requested sign fabrication. lcz o PER OWNER EASEMENTS WILL BE PROVIDED AS NEEDED FOR PRIVATE WATER SERVICE LINE CROSSING LOT D / / X X WOOD FENCE -1 / z "Z m i� -N 09°03'27" E 60.68' / A — w 00 m - - - / 11 +00 /\- + SS SS S S W UTILITY RESTORATION AREA PER EDMONDS STANDARD GU-410 (TYP.) W / / / / \ -W OS (-n�zN z x / C7 00 CD O OZ ' 00 j 9*, C) CD CO 70 • / 280 21� 03 269.99 - 269.73 270 EX 2 70.10 D M N ° REMOVE EXISTING CONCRETE WITHIN THE RIGHT OF 260 WAY & REPLACE W/ASPHALT PER CITY STANDARDS. BLOW-UP DETAIL SCALE. 1 "=4' 250 0 N COMBINED DRY UTILITIES TRENL (GAS, POWER, PHONE, ETC) P� PO2 I \ EX. GRADE @ CIL OF ROAD \ C CO N N N G 270 260 250 A minimum of 3' horizontal separation and 1' vertical separation is required between the dry utilities (power, gas, phone, cable, etc.) and sewer, water, and storm and 5' horizontal from any City main lines. SD IECO SCALE: 1" = 10' 10 5 0 10 20 -G w SS SS y W ASS w- 12+00 SS SD P �P NOTE FINAL RESTORATION WITHIN THE RIGHT-OF-WAY SHALL BE COMPLETED BY THE CONTRACTOR, NOT THE CITY OF EDMONDS. Know what's below. Call before you dig. UTILITY CONFLICT NOTE. CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT R E S U B LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS Apr 25 2024 SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC p INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD CITY OF EDMONDS OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING DEVELOPMENT SERVICES COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH DEPARTMENT CONSTRUCTION. 10+00 10+50 11 +00 94THA VE W PROFILE SCALE: 1 "=30' HORIZ, 1 "=3' VERT DESIGN SPEED = 20 MPH 11 +50 12+00 GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2018 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (2014) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS -BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 14. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 15. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 16. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 17. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 18. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 19. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 20. ALL DISTURBED SOIL AREAS SHALL BE SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 21. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 22. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 23. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 24. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 59. SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 25. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 26. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 27. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 28. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 29. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 30. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 31. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 32. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 33. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM Rr��gY 4P �01�0 O'°F�Prgl 9y c�Y qSN P DRIVEWAY APPROACH (WITHOUT CURB) uj O1 SAWCUT EDGE p wa uf EXISTING ASPHALT a W STREET VARIES \ '\�2" HMA O2 2"-5/8" MINUS CSTC COMPACTED SUBGRADE O3 SECTION A -A NOTES: O1 SAWCUT AND USE TACK COAT BETWEEN ROAD TO DRIVEWAY APPROACH JOINT. SEAL JOINT WITH AR4000 SEALER. O2 DRIVEWAY APPROACH TO BE 2" HMA CLASS 1/2" PG 58H-22. O SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. O 10' EDGE RADIUS. O HMA SHALL BE PLACED FROM EDGE OF EXISTING STREET, A MINIMUM DISTANCE OF 20-FT OR TO PROPERTY LINE, WHICHEVER IS GREATER. --me- REVISION DATE CITY OF EDMONDS DRIVEWAY APPROACH JUNE 2021 TYPE VI PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs} 189� APPROVED BY: R. ENGLISH TR-546 TYPICAL CONS7RUCTIOWSETBACADETAIL NOT TO SCALE 2" TO 6" CONC RISERS (4" MIN - 18" MAX) USING NON SHRINK GROUT PROVIDE SMOOTH FINISH INSIDE AND OUT 2 HANDHOLDS SEE COE STD DTL GU-423 POLYPROPYLENE SAFETY STEP/LADDER 12" OC PRECAST SECTIONS 4" MIN THICKNESS TYP 12" MIN SAND COLLAR OR KOR-N-SEAL MANHOLE KNOCKOUT STEPS FRAME AND COVER NOTES: 1. LOCATE MH LID OUTSIDE THE WHEEL PATH OF THE TRAVEL LANE. 2. BASE REINFORCING SHALL BE #4 REBAR AT 12" OC BOTH WAYS. 3. LARGER MH TO BE REVIEWED ON A CASE BY CASE BASIS USING APWA STANDARDS. 4. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. MH FRAME AND COVER PER COE STD DTL GU-420 I10" MIN TO _ 1 24" MAX _ 24^ 28" MAX 1 6" MAX • ° ECCENTRIC PRECAST CONE 4. a. SEE NOTE 4 a 16" MAX CONSTRUCT CHANNEL SHELF 6" MIN ` REBAR MIN 2" CLEARANCE REVISION DATE CITY OF EDMONDS OCTOBER 2021 TYPE I MH PUBLIC WORKS STANDARD DEPARTMENT DETAIL St. 189(3 APPROVED BY: R. ENGLISH G U - 421 5 TYPE' I MH CS.o NOT TO SCALE NE 114, SEC. 13, T" 27 N., R.03 E., W.M. SNOHOMISH COUNTY, WASHINGTON RESIDENCE w z J cr w a O CLEANOUT a WITH 45' BEND AND CAP CLEANOUT (MAX) (TYP) NOT TO EXCEED 100' BETWEEN CLEANOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2"t FINISHED GRADE Z of w w V) z w ui � w a E0 a 3 a of > �: Of 12" LOCKING COVER SEE NOTE 3 END OF PIPER GRIPPER PLUG (CHERNE 27061 OR APPROVED EQUAL) WATER TIGHT CAP���/. lid RISER LEVELING COLLAR 45' SEE NOTE 4 45. 12" PVC SLEEVE 6" RISER 4" OR 6" SIDE SEWER 6" WYE AND 6" CITY STUB GENERAL CLEANOUTDETAIL 45' BEND 4" OR 6" 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL 3 z SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT r W LEVELING COLLAR NOTES' j 0 o w SEE NOTE 4 ir a a ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 12" f 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12" PVC PRODUCT #00366102 OR APPROVED EQUAL. SLEEVE 6" RISER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: END OF PIPE GRIPPER PLUG (CHERNE 270261 " IN ROADWAYS PER COE STD DWG GU-424 OR APPROVED EQUAL) • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24"x6" TYPICAL CLEANOUT DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP UNDER ASPHALT OR CONCRETE CONCRETE COLLAR REVISION DATE CITY OF EDMONDS i 4, SEWER CLEANOUT DETAILS FEBRUARY 2022 PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs}. 189 APPROVED BY: R. ENGLISH SS - 2 O O 2 SEWER CLEANOUT DETAILS CS. NOT TO SCALE 1' WIDTH VARIES MIN. I (SEE NOTE 5 & 6) HMA CLASS 1/2' PG 58H-22 (SEE NOTE 2) ?.� CURBING (SEE NOTE 7) 2% 2% CRUSHED SURFACE BASE COURSE PER WSDOT STD SPEC 9-03.9(3) (SEE NOTE 1) NOTES: 1. CSBC DEPTH SHALL BE A MINIMUM OF 6" THICK. 2. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. 3. FINAL PAVEMENT JOINTS SHALL BE NEATLY SAW CUT AND UNIFORMLY SEALED PER WSDOT STANDARD SPECIFICATIONS 5-04.3(4)A. 4. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 5. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE TABLE OF STREET STANDARDS FOR PRIVATE EASEMENT AND PAVEMENT WIDTHS. 6. FIRE DEPARTMENT MAY REQUIRE ACCESS TO BE WIDER THAN REQUIRED IN EDMONDS COMMUNITY DEVELOPMENT CODE IF IT IS DETERMINED FIRE FIGHTING OR RESCUE OPERATIONS ARE HAMPERED. 7. 6" CONCRETE EXTRUDED CURB PER COE STD DETAIL TR-522 OR 18" ASPHALT THICKENED EDGE PER COE STD DETAIL TR-533 REQUIRED. REVISION DATE CITY OF EDMONDS PRIVATE STREET APRIL 2021 PUBLIC WORKS (1-4 LOTS) STANDARD DEPARTMENT DETAIL Fs } . 1 g C� APPROVED BY: R. ENGLISH T R - 510 6 PRI DATE STREETS NOT TO SCALE w zWw J Z ram Waw a O N Wac) QOm NOTES: /-(IF STUB FOR FUTURE DEVELOPMENT) SEWER STUB SHALL BE LOCATED 10' INSIDE PROPERTY LINE & STAKED. PLACE 2"x4" TIMBER AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO ENSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS, STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2 x 4 STAKE AT OR ABOVE FINISHED GRADE. w z J w a LOCKING CLEANOUT COVER o PER COE STD DTL SS-200 6" LATERAL SEWER SLOPE - 2% MIN TO 50% MAX 22.5' OR 45' BEND 6" TEST TEE 6" WYE/6" ROMAC SADDLE SEE NOTES 1 AND 2 POSSIBLE SEWER MAIN LOCATION 22.5' OR 45' BEND 6" TEST TEE 6" TEE POSSIBLE I SEWER MAIN LOCATION 1. WHEN TAPPING INTO EXISTING MAIN A ROMAC STYLE CB SADDLE SHALL BE USED. PLACEMENT OF TEE SHALL DEPEND ON DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 2. IF NEW MAIN IS BEING INSTALLED OR MAIN IS BEING REPLACED, SERVICE CONNECTION TO THE MAIN SHALL BE DONE WITH A WYE. WYE SHALL BE AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 3. IF CONNECTING EXISTING PRIVATE SIDE SEWER TO NEW CITY LATERAL, A CONCRETE/PVC STRONGBACK FERNCO RC SERIES OR ROMAC COUPLING SHALL BE USED AND SECURED PER MFR'S INSTRUCTIONS. 4. BORING OF SERVICES WITHIN RIGHT OF WAY IS NOT ALLOWED. 5. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 6. IF STUB FOR FUTURE DEVELOPMENT, USE RUBBER JOINT BISCUIT PLUG OR OTHER APPROVED WATERTIGHT PLUG. REVISION DATE CITY OF EDMONDS MAY 2018 NEW LATERAL SEWER PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs} 189,j APPROVED BY: R. ENGLISH SS-202 3 NEW LATERAL SEWER DETAIL NOT TO SCALE FINAL JOINT SHALL BE A NEAT SAW CUT STRAIGHT LINE. ALL EXPOSED VERTICAL HMA CLASS 1/2" EDGES SHALL BE TACKED NEATLY PER PG 58H-22 WSDOT STANDARD SPECIFICATIONS 5-04.3(4) r (SEE NOTES 4 & 5) 1' APPROVED TACK OR APPROVED EQUAL AND SEALED PER WSDOT STD 5-04.3(4)A. 1' SLOPE EXCAVATION TO AVOID UNDERMINING EXISTING PAVEMENT. ...................................... ........ ...................... J EXISTING HMA EXISTING\ \ a MATERIAL BEDDING MATERIAL (1-1/4" MINUS) CRUSHED SURFACE BASE COURSE (SEE NOTE 3) IMPORT BACKFILL SHALL BE COMPACTED TO 95% MAXIMUM DENSITY (SEE NOTE 2) TRENCH WIDTH NOTES: 1. SEE CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF THE CURRENT WSDOT STANDARD SPECIFICATIONS FOR BACKFILLING REQUIREMENTS. 2. SUBMIT PROCTOR AND DENSITY TESTS FROM CERTIFIED TESTING COMPANIES DOCUMENTING THAT THE BACKFILL MEETS A MINIMUM OF 95% DENSITY PER ASTM D 1557. 3. CSBC DEPTH SHALL BE A MINIMUM OF 6", AND SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 6". 4. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" FOR RESIDENTIAL ROADS AND 6" FOR COLLECTORS/ARTERIALS. 5. ALLEY HMA DEPTH SHALL BE A MINIMUM OF 2" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 2" SHALL MATCH EXISTING. 6. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 7. FINAL PAVEMENT JOINTS SHALL BE NEATLY SAW CUT AND UNIFORMILY SEALED WITH WSDOT STANDARD SPECIFICATIONS 5-04.3(4)A APPROVED JOINT SEALANT OR APPROVED EQUAL. REVISION DATE CITY OF EDMONDS TYPICAL HMA AND APRIL 2021 7- 1UTILITY PATCH PUBLIC WORKS STANDARD DEPARTMENT DETAIL 777 -1 Fg } . 18 9,3 r APPROVED BY: R. ENGLISH G U - 410 7 TYPICAL HMA AND UTILITYPATCH C5 0 NOT TO SCALE a N R.O.W. FINISHED GRADE PROPERTY LINE O 0' METER SUPPLIED BY CITY O �- =I, I I I I BALL VALVE - - - - - I I I r, -------- H \��--�,/ Li C C L- K DIRECTION OF FLOW A D MATERIAL LIST: AO ALL 1" SERVICES TO BE TYPE "K" SOFT COPPER TUBING OB 1" BALL CORP. STOP WITH CC THREAD INLET AND COPPER (CTS) GRIP OUTLET (FORD OR MUELLER) CO DUAL PURPOSE UNION OD MIPT X CTS GRIP BALL VALVE CURB STOP EQUAL TO FORD B84-4440 FOR 1" OWHEN REPLACING EXISTING SERVICES: 1" METER SETTER WITH ANGLE BALL METER VALVE 15" HIGH WITH DUAL E PURPOSE UNIONS ON INLET AND OUTLET, HORIZONTAL IN HORIZONTAL, OUTLET EQUAL TO FORD VB74-15W-11-44 WHEN PLACING NEW SERVICES: USE SAME AS ABOVE AND ADD A SINGLE CHECK, EQUAL TO FORD VBH74-15W-11-44 OF 1" CC TAP SERVICE SADDLE EQUAL TO ROMAC 101S OG IN UNPAVED AREAS: CARSON 1324 MSBCF WITH DUCTILE IRON COVER AND CAST IRON READER DOOR; IN PAVED AREAS: ARMOR CAST A6001946PCX12 BOX W/ A600196969 RCI LID OH FOR VACANT LOT (FUTURE USE) LOCATION MARKED WITH PAINTED 2" X 4" STAKE WITH "WATER" STENCILED ON IT OI 14 GA. VINYL COATED WIRE TRACER (TAPED TO PLASTIC PIPE EVERY 10') TO BE GROUNDED AT METER AND HOUSE OJ SCHEDULE 40 3/4" OR 1" PLUG, REMOVE WHEN CONNECTION IS MADE TO CUSTOMER LINE WITH COMPRESSION FITTING O WATER SERVICE TO HOUSE, INSTALLED BY OWNER/CONTRACTOR (PER PLUMBING CODE) OL PROPERTY OWNER RESPONSIBLE FOR PURCHASING 3/4" OR 1" METER THROUGH THE CITY AT DEVELOPMENT SERVICES DEPARTMENT; CITY WILL SUPPLY AND INSTALL METER AFTER PURCHASE; IF USING 3/4" METER, CONTRACTOR WILL PROVIDE REDUCERS OM BACK SIDE OF METER BOX SHALL BE SET AT THE PROPERTY LINE UNLESS APPROVED BY THE CITY ENGINEER. METER BOXES SHALL NOT BE SET IN DRIVEWAY AREAS UNLESS TRAFFIC RATED BOX IS APPROVED BY CITY ENGINEER. REVISION DATE CITY OF EDMONDS 1" WATER SERVICE JANUARY 2021 (FOR 3/4" & PUBLIC WORKS 1 " METERS) STANDARD DEPARTMENT DETAIL 77 Fs { 189APPROVED BY: R. ENGLISH WA-1 30 4 I " WATER SERVICE DETAIL C5 0 NOT TO SCALE RESUB Apr 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT UTILITY CONFLICT NOTE Know what's below. Call before you dig. CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE CAD 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION.