Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD BLD2024-0100+PLANS+1.23.2024_11.31.38_AM+4015008
REVISIONS FOR QUESTI❑NS, CALL THE Seattle ❑ffice REGI❑N 85 PH❑NEi (425) 212 - 5996 EMAIL reg85@captiveaire,com T-Tnnn TNFnRUATTOM - .TnR,4F5797nS PATENT NUMBERS AC-PSP (UNITED STATES) - US PATENT 7963830 B2, AC-PSP WALL (CANADA) - CA PATENT 2820509. AC-PSP ISLAND (CANADA) - CA PATENT 2520330. MAX EXHAUST PLENUM TOTAL HOOD C❑NFIG RISER(S) END TO HOOD TAG MODEL MANUFACTURER LENGTH C❑❑KING TYPE APPLIANCE DESIGN TOTAL SUPPLY HOOD WIDTH LENG HEIGHT DIA CFM VEL SP NO TEMP DUTY CFM/FT EXH CFM CFM C❑NSTRUCTI❑N END ROW 624 43OSS 1 Cookline CAPTIVEAIRE 10, 0" DEG I HEAVY 250 2500 4' 16" 2500 1790 -0.909" 2250 ALONE ALONE ND-2oPSP-F WHERE EXP❑SED unnn TITFnRALfATTnAT FILTER(S) LIGHT(S) UTILITY CABINET(S) HOOD TAG EFFICIENCY @ 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM HOOD HANGING TYPE SIZE MODEL # QUANTITY NO TYPE QTY HEIGHT LENGTH MICR❑NS QTY TYPE GUARD L❑CATI❑N SIZE PIPING WEIGHT 857 SEE FILTER 1 LIGHT 1021 1 Cookline CAPTRATE SOLD FILTER 7 20' 161, SPEC 3 RECESSED ROUND NO RIGHT 12"x60'x24' TANK FS 4,0/4,0 DCV-1111 YES LBS 1 FAN T-Tnnn nPTTOArS HOOD NO TAG ❑PTI❑N LEFT END STANDOFF (FINISHED) 1" WIDE 60" LONG INSULATED. INSULATI❑N FOR TOP OF HOOD. 1 Cookline INSULATI❑N FOR BACK OF HOOD. SENSOR -CV, LEFT WALL AS END PANEL. PF. R. FnR,4 TF. n 'WTPPT.Y PT,F. ATTTM(.S' ) HOOD NO TAG P❑S LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP 1 Cookline Front 133' 20' 6" MUA 12" 28" 750 0,211" MUA 12" 28" 750 0,211" MUA 12' 28' 750 0.211' SYSTEM DESIGN VERIFICATI❑N (SDV) IE ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIEICATI❑N (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE ❑PERATI❑N AND INSTALLATI❑N MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND C❑RRESP❑NDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES ❑FFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITI❑NAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPR❑PRIATE SALES OFFICE WILL BE N❑TIFIED. THERE WILL BE NO ADDITI❑NAL CHARGES FOR MANUFACTURER DISCREPANCIES. 1/2' - 13 TPI GRADE 5 (MINIMU"` STEEL HEX NUTS 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2' - 13 TPI GRADE 5 (MINIMU STEEL ALL-THRE 1/2' - 13 TPI GRADE 5 (MINIMU STEEL HEX NUT. 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. HOOD CORNER HANGING ANGLE "'"-DWARE BY INSTALLER) HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD), 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2' - 13 TPI GRADE 5 (MINIMUI„ STEEL HEX NUTS. ASSEMBLY INSTRUCTI❑NS 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2' GRADE 5 (MINIMUM) STEEL — FLAT WASHER. 1/2' - 13 TPI GRADE 5 (MINIMUM)' STEEL ALL -THREAD, 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2' GRADE 5 (MINIMUM) STEEL — FLAT WASHER. FULL LENGTH HANGING ANGLE (HARDWARE BY INSTALLER) FULL LENG1 HANGING AN (WEIGHT BE ANCHOR PO] FOR HOOD). 1/2' GRADE (MINIMUM) S FLAT WASHI 1/2' - 13 1 GRADE 5 (M_......... STEEL HEX NUT. ASSEMBLY INSTRUCTI❑NS 1/2' - 13 TPI GRADE 5 (MINIMU"` STEEL HEX NUTS 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2' - 13 TPI GRADE 5 (MINIMU STEEL ALL-THRE 1/2' - 13 TPI GRADE 5 (MINIMU STEEL HEX NUT. 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. SUPPLY PLENUM HANGING ANGLE o/ARE BY INSTALLER) SUPPLY PLENUM HANGING ANGLE (WEIGHT BEARIN( ANCHOR POINT FOR SUPPLY PLENUM). 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2' - 13 TPI GRADE 5 (MINIMU... STEEL HEX NUT. ASSEMBLY INSTRUCTI❑NS SPECIFICATI❑N: CAPTRATE® GREASE-ST❑P® SOLO FILTER THE CAPTRATE GREASE -STOP SOLD FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN C❑NJUNCTI❑N WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTI❑NAL FILTRATI❑N EFFICIENCY. FILTER IS STAINLESS STEEL C❑NSTRUCTI❑N, AND SIZED TO FIT INT❑ STANDARD 2-INCH DEEP HOOD CHANNEL(S), UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTI❑N EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICR❑NS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICR❑NS IN SIZE AND LARGER, WITH A C❑RRESP❑NDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05, MANUFACTURER APPROVED FOR USE IN S❑LID FUEL APPLICATI❑NS AS A SPARK ARRESTER. EFFICIENCY VS. PARTICLE DIAMETER PRESSURE DROP VS. FLOW RATE 100 3.50 80 r U Z w U 60 L� LL w 40 Z R U U Q 20 0 0.1 1,0 10,0 PARTICLE DIAMETER, (UM) CAPTRATE FILTERS ARE BUILT IN C❑MPLIANCE WITHi, NFPA #96. NSF STANDARD #2, UL STANDARD #1046. INT, MECH. CODE (IMC), ULC-S649, ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 3.00 CD W 2.50 2.00 0_ 0 ra 1.50 w w 1.00 0.50 0.00 L 0 500 1000 1500 FLOW RATE (CFM) BUILT ACCORDANCE J WITH NFPA 4040 No. 96 APPROVED 0 0 PLANS MUST BE I � ON JOB SITE City Of Edmonds Building Department Work . MECHANICAL Address:: 21104 70TH AVE W ......................................................................................................................... Owner KUAMA'S FISH MARKET ..............................................................................: ...................................................: Approved Date 03/19/2024 ..........................................................: .......................... Building Official Elrl,(i Carter .... .. ...... Permit Number BLD2024-0100 E i -P � 3 0 3 �0 p� CDLL_i CD i L 0F\) QJ 0 Q <z d Q _ x W O VI In In c5 `4_ o E7 0 E N 75 �!z CL1 Ld DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L - R 8 5 SCALE: 3/4" = 1'-0" HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI RECEIVED MASTER DRAWING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 ANGLES AND CEILING ANCHOR POINTS WITH 1/21, GRADE 5 ANGLES AND CEILING ANCHOR P❑INTS WITH 1/2' GRADE 5 Jan 25 2024 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI DE ECITY OF LO MEN SOERVCES GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE DEPARTMENT DOUBLED HEX NUT CONFIGURATI❑N BENEATH HOOD HANGING DOUBLED HEX NUT CONFIGURATION ABOVE CEILING DOUBLED HEX NUT C❑NFIGURATI❑N ABOVE CEILING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF ANCHORS, SINGLE HEX NUT BENEATH HANGING ANGLE IS ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4" OF ALL HEX NUTS TO 57 FT-LBS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE SHEET NO. HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. ALL HEX NUTS TO 57 FT-LBS, 1 REVISIONS 1' LAYER OF INSULATI❑N FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0' REQUIREMENTS CLEARANCE TO C❑MBUSTIBLE SURFACES. INSTALLER MUST C❑NFIRM HOOD IS INSTALLED SUC THAT THE SPECIFIED WALL, ACTING AS AN END PANEL IS MATED TIGHT TO THE CORRECT END OF HOOD T ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTIN( N❑N-COMPLIANCE WILL NULLIFY THE ETL LISTIN( V❑ID THE MANUFACTURER'S WARRANTY, AND HOLD TH CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COST: AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTI❑N. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20' FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20' UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING, EXHAUST RISER, HANGING ANGLE. 20' CAPTRATE SOLO FILTER WITH HOOK. 1' LAYER OF INSULATI❑N FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO C❑MBUSTIBLE SURFACES. IT IS THE RESP❑NSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND C❑MBUSTIBLE MATERIALS IS IN C❑MPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP. LEFT WALL AS END PANEL. 1' LAYER OF INSULATI❑N FACTORY INSTALLED IN INTERNAL BACK STANDOFF. 22 1/4" 44 1/4' I 44 1/4" 10' 0'N❑M,/10' 0,00'❑D, 11'-1,00' OVERALL LENGTH PLAN VIEW — HOOD #1 (Cookline� 10' 0.00" LONG 6024ND-2—PSP—F 12' RECESSED ROUND LED FIXTURE AND LED LIGHT, q FACTORY INSTALLED 0 INCH 4RANCE TO COMBUSTIBLE TTACHING PLATES. ;UPPLY RISER WITH IOLUME DAMPER, 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT n n E 1 m Pq W '', 4) cc I � 7 O 3 �0 CU CuCDW CO I Q1 QJ O_ > Q m c5 Q X W O 75 � _Ln d 0 E7 O F_ N 75 Cu W DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L — R 8 5 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 2 REVISIONS FACTORY PIPING EXTENDS A OF 6' ABOVE THE TOP OF TF EXHAUST RISER. HANGING ANGLE 20' CAPTRATE SOLD FILTER WITH HOOK 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED —COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS GREASE DRAIN WITH REMOVABLE CUP. LEFT WALL AS END PANEL GAS VALVE FOR FS#1— 11 1/2'— —� E 25.00' 01 I nuc z z w a HOOD # 1 (Cook(Ine) JOB # 6571705 FS # 1 MODEL, ND-2-PSP-F SIZE, 60'x24' LENGTH, 10' 0' unnn r7annr A NOZZLE HEIGHT 35-50' FROM COOKING SURFACE. (45.25') RECESSED ROUND LED FIXTURE AND LED LIGHT. J FACTORY INSTALLED 0 INCH kRANCE TO COMBUSTIBLE fTACHING PLATES. UPPLY RISER WITH IOLUME DAMPER, 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. SECTION VIEW - MODEL 6024ND-2-PSP-F HOOD - #1 — SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS, - FIELD INSTALLED DR❑PI FACTORY WILL PR❑VIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD -INSTALLED. - SHIP LOOSE DR❑PI FACTORY WILL PR❑VIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD -INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - ❑VERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN ❑BSTRUCTI❑N. - IF APPLICABLE, EXTENDED PRE -PIPED DROPS ARE SHIPPED LOOSE, - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSI❑NS LISTED REPRESENT THE C❑❑KING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM C❑MPLIES WITH U,L, 300 REQUIREMENTS, - ❑L-F NOZZLE PART NUMBER REPLACES 3070-3/BH-10-SS JOB #1 6571705. JOB NAMEI ** KUZMA'S EXPANSI❑N - EDM❑NDS WA - R2. SYSTEM SIZEI TANK-SP-2 DESIGN FPI 33, MAXIMUM FPI 40. HOOD # 1 10' 0.00' LONG x 60' WIDE x 24' HIGH. RISER # 1 SIZEI 16' DIA. HOOD # 1 METAL BLOW -OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITI❑NAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK C❑NTAINS ANY H❑RIZ❑NTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT -DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITI❑NAL DOWNSTREAM DETECTI❑N. LEGEND - FIRE CABINET TANK SYSTEM 1 4 GALLON TANK, 2 PRIMARY ACTUATOR RELEASE. 3 SECONDARY ACTUATOR RELEASE. 4 PRESSURE SUPERVISI❑N SWITCH, 5 PRIMARY HOSE ASSEMBLY. 6 SECONDARY HOSE ASSEMBLY. 7 REMOTE MANUAL ACTUATI❑N DEVICE. FTRF .<ZV.4ZTFV TATFnPUATTnAT — _TnR4R�717n., INCLUDES, FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TESTi ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2', PERMIT, AND SYSTEM TEST. EXCLUDES, UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON -SITE RE -PIPING DUE TO EQUIPMENT LAYOUT CHANGES. FIRE SYSTEM TAG TYPE SIZE MAX FP DESIGN FP INSTALLATION NO SYSTEM LOCATION ON HOOD 1 TANK FS 4.0/4.0 40 33 1 FIRE CABINET RIGHT RIGHT, HOOD 1 .-A C1 TTA T TTLI/c+1 FIRE SYSTEM TAG TYPE SIZE SUPPLIED BY NO 1 SC ELECTRICAL 2.000 CAPTIVEAIRE SYSTEMS FTAF CVCTFaT PART( TTCT FlFV FIRE QTY BY QTY BY SYSTEM TAG KEY NUMBER - PART DESCRIPTION FACTORY DIST NO 0 - 0 - TANK FIRE SUPPRESSION POST -DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET. 1 0 0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET. 1 0 0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO, 1 0 CLOSE ON TEMP RISE AT 360'F. 0 - 0 - 32-00002 QUIK SEAL - 1/2' (UL). 1 0 0 - 0 - 4429K153 1/2' MALE NPT TO 1/2' FEMALE NPT ELBOW, BRASS. 2 0 0 - 0 - 4429K422 1/2' X 1/4' BRASS REDUCING BUSHING. 1 0 0 - 0 - 79525 1/2' 90 PRO -PRESS ELBOW WITH 1/2" NPT FEMALE CONNECTION, VIEGA. 1 0 0 - 0 - 79580 1/2' X 1/2' PRO -PRESS TEE X 1/2" NPT FEMALE CONNECTION, VIEGA. 2 0 0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES 1 0 PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION, 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5' BRAIDED STAINLESS STEEL, 1 0 TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 2 0 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID 1 0 ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION, 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 8 0 0 - 0 - 9055455PC PRO PRESS 1/2 PRESS X PRESS 90 ELBOW LD, 6 0 1 0 - 0 - 909720OPC PRO PRESS PC611 1/2 PRESS TEE LD. 6 0 0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16' ZINC, TANK 4 0 FIRE SUPPRESSION, 0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5' DEEP BACK BOX, RED COLOR. 1 0 0 - 0 - A31484 1/4' NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4' FLARE X 1/4' 1 0 MPT HALF UNION. USED ON TANK SERVICE PORT, 0 - 0 - BI145 3/8' BLACK IRON 90 ELL. 2 0 0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION 2 0 IN UTILITY CABINETS, TANK FIRE SUPPRESSION, 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 6 0 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 2 0 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 2 0 16 - 16 - 79210 1/2' X 3/8' NPT MALE ADAPTER, VIEGA. 7 0 16 - 16 - OL-F NOZZLE - TANK PROTECTION APPLIANCE COVERAGE NOZZLE (INCLUDES METAL 7 0 BLOW OFF CAP, LANYARD, USED WITH CHROME -PLATED PIPE), 26 - 26 - QSA-3/8 QUIK SEAL - 3/8' (UL). 7 0 34 - 34 - A0034331 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION) 1 0 WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. RED COLOR, GAS VALVES AND STRAINERS GAS VALVE SIZING GAS VALVE DIMENSIONS INSTALLATION PART NUMBERS TYPE SIZE VOLTAGE MIN. INLET PRESSURE MAX. INLET PRESSURE FLOW AT 1 IN.W.C. DROP NATURAL GAS FLOW AT 1 IN.W.C. DROP PROPANE DIM "A" DIM "B" DIM "C" DIM "D" DIM "F" DIM "G" MOUNTING ORIENTATION GAS VALVE PART NUMBER STRAINER PART NUMBER GAS VALVE STRAINER KIT ELECTRICAL 2" 120 VAC 0 PSI (0 IN.W.C.) 5 PSI (138 IN.W.C.) 2,940,500 BTU/HR 1,908,048 BTU/HR 7-5/8" 6-3/8' 7-1/4" 7-13-16" 15-5/8" 13-15/16" HORIZONTAL/ VERTICAL 8214280 4417K68 (SC)EGVA2 DIM "A" DIM "G" ALL GAS VALVES/STRAINERS CALCULATIONS PROPER CLEARANCE MUST BE PROVIDED IN ORDER TO SERVICE THE TO CALCULATE GAS FLOW FOR OTHER THAN 1 IN.W.C. PRESSURE DROP STRAINERS A MINIMUM OF 4" CLEARANCE DISTANCE MUST BE NEW BTU/HR = (BTU/HR AT 1 IN.W.C. PRESSURE DROP) X NEW PRESSURE DROPo.5 PROVIDED AT THE BASE OF THE STRAINER CUSTOMER MUST VERIFY TO CALCULATE GAS FLOW FOR OTHER THAN 0.64 SPECIFIC GRAVITY BTU CONSUMPTION AS WELL AS PRESSURE RATING SPECIFIC GRAVITY NEW BTU/HR = (BTU/HR AT 0.64) X (0.64 / NEW SPECIFIC GRAVITY)0- OF NATURAL GAS = 0.64, SPECIFIC GRAVITY OF LP = 1.52. M „B„ / FRIC GAS VALVE. FLOW. DIM "C" DIM "D" STRAINER RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT m n n 0 E i 1 m m or" ti w O 0 cc I � r_p V 3 � 7 0 3 �0 LLJ CU CD CO I Q1 17 n� 0 / /r C5 x W O 75 C5 `4_ O E7 O E IN 75 Cu Ld DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L — R 8 5 SCALE: 1/2" = 1'-0" MASTER DRAWING SHEET NO. 3 F,XT-TATI.S'T FAN TNFnRAlfATTnN — mRY6.5797n5 REVISIONS FAN MOTOR DISCHARGE WEIGHT UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM ENCL HP BHP PHASE VOLT FLA VEL❑CITY (LBS) S❑NES N❑ 1 KEF-1 1 DU180HFA CAPTIVEAIRE 2500 1.500 1192 TEFC,PREMIUM 2,000 1,2980 3 208 7.3 577 FPM 204 15 MUA FAN INFORMATION - JOB##6571705 FAN MIN DESIGN MOTOR WEIGHT UNIT TAG QTY FAN UNIT MODEL # BLOWER H❑USING CFM CFM ESP RPM ENCL HP BHP PHASE VOLT FLA MCA M❑CP (LBS) S❑NES NO 2 MAU-2 1 A1-D,250-16Z 16Z-1-MOD Al-D,250 1000 2250 0.500 2409 ❑DP -ECM 2.500 1.7070 3 208 5.7 8,3A 15A 487 27.5 GAs FTR.F. n ILEAKF. -TIP ATR. TINTT(.S ) FAN INPUT OUTPUT BURNER UNIT TAG BTUs BTUs TEMP RISE REQUIRED INPUT GAS PRESSURE GAS TYPE EFFICIENCY(%) NO 2 MAU-2 116572 107246 45°F 7 IN. W.C. - 14 IN. W.C. NATURAL 92 FA N nPTTnv<< FAN UNIT N❑ TAG QTY DESCRIPTI❑N 1 GREASE BOX 1 KEF-1 1 FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS 1 2 YEAR PARTS WARRANTY 1 SIZE 1 TEMPERED C❑MMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS 1 INLET PRESSURE GAUGE, 0-35" 1 MANIF❑LD PRESSURE GAUGE, -5 TO 15" WC 2 MAU-2 1 SHIP LOOSE GAS STRAINER 3/4' 1 M❑T❑RIZED BACKDRAFT DAMPER FOR Al-D H❑USING - MEETS AMCA CLASS 1A RATING 1 ECM WIRING PACKAGE -SUPPLY - PWM SIGNAL FROM ECPM03 PREWIRE (3 - PHASE ZIEHL MOTOR) 1 2 YEAR PARTS WARRANTY FAN FAN EXHAUST SUPPLY UNIT TAG NO GREASE GRAVITY WALL SIDE GRAVITY M❑T❑RIZED WALL CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT 1 KEF-1 YES 2 MAU-2 YES C IR.R A.S'.S'F, iLfRT,TF..S' NO ON TAG WEIGHT ITEM SIZE FAN 1 # 1 KEF-1 52 LBS CURB 26.500"W X 26,500"L X 24,000"H VENTED HINGED. 2 # 2 MAU-2 63 LBS I CURB 21,000"W X 71,000"L X 14,000"H INSULATED. HMI SCHEDULE UNIT NUMBER HMI # HMI L❑CATI❑N TEMP AVERAGING M❑DBUS ADDRESS FAN #2 HMI #1 - UNIT HMI # 1 MOUNTED IN UNIT NOT AVERAGED 55 FAN #1 DU180HFA - EXHAUST FAN (KEF-1) 33 TOP VIEW 26' 37 3/8' FEATURES: - DIRECT DRIVE C❑NSTRUCTI❑N (N❑ BELTS/PULLEYS). - ROOF MOUNTED FANS. - RESTAURANT MODEL. - UL705 AND UL762 AND ULC-S645 - VARIABLE SPEED CONTROL, - INTERNAL WIRING. - THERMAL OVERLOAD PR❑TECTI❑N (SINGLE PHASE), - HIGH HEAT ❑PERATI❑N 300"F (149'C), - GREASE CLASSIFICATI❑N TESTING. - NEMA 3R SAFETY DISC❑NNECT SWITCH. NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE C❑NTINU❑USLY WHILE EXHAUSTING AIR AT 300°F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH❑UT ANY DETERI❑RATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE ❑PERATI❑N, ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE C❑NTINU❑USLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600"F (316'C) FOR A PERI❑D OF 15 MINUTES WITH❑UT THE FAN BEC❑MING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE C❑NDITI❑N. ❑PTI❑NS - GREASE BOX. - FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS. - 2 YEAR PARTS WARRANTY. HINGE KIT ENTED CURB. GE UCTI❑N, \ \ � ROOF ❑PENING \ / 26" DIMENSI❑NS, RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 0 1 m I Q (7- _O V1 s d n w ,r, a OI Eft 0j _p V1 0J i •• Q 3 S o O O E 75 Cu W DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L - R 8 5 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 4 REVISIONS FAN #2 Al-D,250-16Z - HEATER (MAU-2) 1, DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 16' DIRECT DRIVE FAN. 2, INTAKE HOOD WITH EZ FILTERS. 3, DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT, 4, DOWN DISCHARGE C❑NSTRUCTI❑N FOR SIZE 1 DIRECT DRIVE AHUS, 5, GAS PRESSURE GAUGE, 0-35', 2,5' DIAMETER, 1/4' THREAD SIZE, 6, GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5' DIAMETER, 1/4' THREAD SIZE. 7, SHIP LOOSE GAS STRAINER, TO BE INSTALLED UPSTREAM OF UNIT C❑NNECTI❑N. 3/4' C❑NNECTI❑N. 8, M❑T❑RIZED BACK DRAFT DAMPER 16' X 18' FOR SIZE 1 STANDARD & MODULAR HEATER UNITS W/EXTENDED SHAFT, STANDARD GALVANIZED C❑NSTRUCTION, 3/4' REAR FLANGE, LOW LEAKAGE, TFB120S ACTUATOR INCLUDED. 9, ECM WIRING PACKAGE FOR ZIEHL SUPPLY MOTORS WITH PWM SIGNAL FROM ECPM03 PREWIRE, 10, HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTION). 11, 2 YEAR PARTS WARRANTY. SUPPLY SIDE HEATER INFORMATION; )KN❑TE; SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST WINTER TEMPERATURE = 30'F, TEMP. RISE = 45'F, BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD BTUs CALCULATED OFF ACTUAL AIR DENSITY. NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL OUTPUT BTUs AT ALTITUDE OF 0.0 FT. = 108169. DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW, D❑ NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE INPUT BTUs AT ALTITUDE OF 0.0 FT. = 117575. TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. OUTPUT BTUs AT ALTITUDE OF 237 FT. = 107246, SUGGESTED STRAIGHT DUCT SIZE IS 14' x 14'. INPUT BTUs AT ALTITUDE OF 237 FT. = 116572. CURB OUTER 4 DISCHARGE ❑PE 13 3 7/8' LIFTING LUG. 29 3/4' FOR FIELD WIRING. 118 5/8' 32 1/8' 42 1/8' (AIRFLOW, SERVICE DISCONNECT SWITCPF BLOWER/MOTOR ACCESS DOOR 124" SERVICE DIRECT FIRED MODULE, 39 9/16' AIRFLOW, 3/4' NPT, 0 7 13/16' o o o DIRECT FIRED (DF) PROFILE PLATE ASSEMBLY DIRECT FIRED PR❑FILE PLATE SPECIFICATIONS; DESCRIPTION; DIRECT FIRED BURNERS SHALL HAVE PATENTED (US PATENT NO,; US6629523B2), SELF-ADJUSTING PR❑FILE PLATES DESIGNED TO ENSURE PROPER AIR VEL❑CITY AND PRESSURE DROP ACROSS THE BURNER, PR❑FILE PLATES SHALL ALLOW BURNERS TO ACHIEVE CLEAN COMBUSTION BY LIMITING BY-PRODUCT LEVELS TO A MAXIMUM OF 5PPM OF CARBON M❑N❑XIDE (CO), AND 0,5PPM OF NITROGEN DI❑XIDE (NO2:DIRECT FIRED UNITS SHALL BE CONFIGURED WITH THE BLOWER MOUNTED DOWNSTREAM OF THE BURNER. THIS ARRANGEMENT WILL ENSURE A CONSISTENT AIRFLOW, REGARDLESS OF INLET AIR TEMPERATURE. APPLICATION; SPRING-L❑ADED BURNER PR❑FILE PLATES ARE ENGINEERED TO AUTOMATICALLY REACT TO THE MOMENTUM OF A FRESH AIR STREAM, WITH❑UT THE NEED FOR ANY MOTORS OR ACTUATORS TO MECHANICALLY ADJUST THEM. WITH THIS FEATURE, ALL DF UNITS ARE DESIGNED FOR DEMAND CONTROL VENTILATION (DCV) REQUIREMENTS, CERTIFICATIONS, ALL PR❑FILE PLATE ASSEMBLIES SHALL BE INCLUDED IN THE DF UNIT'S ETL LISTING AND COMPLY WITH COMBINED SAFETY STANDARDS ANSI Z83,4 AND CSA 3,7 (N❑N-RECIRCULATING DF HEATERS) AND ANSI Z83,18 (RECIRCULATING DF HEATERS), GENERAL C❑NSTRUCTI❑N; -PROFILE PLATES SHALL BE FORMED FROM G90 GALVANIZED STEEL. -PROFILE PLATES SHALL VARY IN SIZE PER UNIT. -PROFILE PLATES SHALL BE MOUNTED ALONG THE SAME PLANE AS THE DISCHARGE OF THE BURNER, -DESIGN SHALL INC❑RP❑RATE PROPERLY TORQUED, PERMANENTLY MOUNTED SPRING HINGES, -SPRING HINGES SHALL BE MADE FROM PLATED STEEL, " ^ 'n 1 E CPO 3 3/4' ° V _ 14' 10 1/4' MINIMUM 10 1/4' STRAIGHT 14' EQUIPMENT CURB. DUCT PER AMCA* Q 3 (� 21' 71' - ROOF OPENING 2' SMALLER THAN CURB DIMENSION, L 7 MIN, 14' O 3 �0 0-1 QJ O W CO I Q1 QJ _ _V1O Q � OPTIONS( S - FULL BOTTOM CORNERS, d S Q � X W 0 75 � _V1 d 0 E7 O E 71 N 75 21' / \ Cu Ld 1 L_ ri 20 GAUGE STEEL C❑NSTRUCTI❑N. RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L — R 8 5 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 5 REVISIONS NOTES ■ = S4 and S6 1 m y be needed for NFBUP- S, Wire to ILIA and IL1B in DCV o YWW & D7 ORDE-DV-1 MOTOR o-RD CONTROL FROM 0BK 2 ECPM03 SHIELCDI ST-01 OL-01 C} K Li T1 x,Ti BK — OBK 13 041 L21 o-BK 15 6 L31 T3 xT3 BK J __ &HB BK-3 3 SW-01 r C� ° 01 w 01R, H HHGR- N a 4 C J9 120V 5 6 J] 7 8 — Jc 9 I/P TRIPS UPON 120VAC �NmR IEL>-A2<D1A-1�N 10 JMUAU Boa1"UVd ppNN r� PROD o-10VD Ru4 III WMENNENNIII mmm®m®®mm 987654321 D1 181716151413121110 J8 Jl J2 J3 J4 JS J6 EDCAL J2 HMI LDCAL J3 J2 SPACE NOT RES HMI HMI IF SPACE SENSOR IS WIRED 0M00©0©©0 mmm®m®®mm 987654321 RDOL J36181716151413121110 (40VA)—TR-05 BK 1200 H H N N )emeem( meemOeme eme J12LDI-1 1 AI-1 -- J14�AI-2-LAI-3 J 28LDI-2�AI-4 bd V BP .r 7654321 1413121110 9 8 J 13 LBC I U W CUI 0- m®®mm00 FT 1 MODBUS J16 J383 1 f8 e m700 R 0 BL-24VAC e GY-INTLK e Q 1 0 8 e G m W 0 T 1 0 J11 e SN-01 INTAKE 0 ED e O e SN-04 � � DISCH/HIGI 10 e J 15� 1 e m ED E)0 0 e W 0 10 e J35 CUMPUNENT LIST I ARFI DESCRIPTION CB-01 CIRCUIT -BREAKER B3 FR-01 EVB/ECM-ACU+Sl, 1-MP BE FSC-01 FIREYE-FLAME-SAFETY BE MT-01 SUPPLY -MOTOR -_ MT-05 INTAKE_➢AMPER-MTR OL-XX MTR-DVERLOA➢ D2 SN-XX TEMP_DENSER 11/11/11117 ST-XX NTR_START" 12 SW-01 DISCONNECT -SWITCH 2 TR-11 CTRL_TRANSFMR B= TR-02 IGNITION_'RANSFMR BS TR-05 BOARD-POWER_TRFMR E5 VA-01 PILOT GAS VALVE F7 VA-02 MAIN GAS VALVE F7 VA-03 MOD _ GAS -VALVE 65 1 crcun — —FILD W1RD!<i FPCIDIM WIRIM BK- BLACK YW- YELLOW BL- BLUE GY- GREY BR- BROWN PR- PURPLE OR- ORANGE RD- RED WH- WHITE GR- GREEN OR/BL- [REEL STRIPE BL/RD- BL/RD STRIPE RD/GN- R➢/GN STRIPE WH/BL- WHIRL STRIPE JOB NAME Kuzma's Ex ansl,,, DRAWING TITLE DESCRIPTION OF OPERATION MUA BOARD (DETAILS TO FOLLOW) JOB NO DRAWN BY 6571705 AUTO TYPE DATE Y 1/22/2024 DwG NWW6571705-2 Installation Wiring JOB 6571705 - Kuzma's Expansion - Ealmonds W... DRAWING NUMBER RP6571705-2 SHIP DATE 112212024 MODEL A1-D.250-16Z nst ed Dotions 120 V 1 PH. 240 V 1 PH. 208/460/600 V 3 PH, Disconnect Disconnect Disconnect Switch Switch Switch Gal -flex co741!0 Gal -flex conduit Gal -flex conduit (in � Cln unit) � (In unit) Factory Factory Factory wiring wiring wiring Field Wired Switch ■ )BK ■ Customer (WH ■ ■ ■ Customer )BK ■ ■ ■ Customer 7HG (R�W GR upp0ed RD GR supplied BKHKB supplied wlring wiring wlring STANDING POWER RD & WH Wire (115V, 1 PHASE) Power Connection See above details, TO J16-5 & J16-6 ON NUA FIELD WIRED CONTACTS WHEN USED WITH PREWIREct2 s� _ WIRE TO SFC1/S1FO1 DAMPER INTERLOCK mDaO� WIRE TO IL1A & IL1B D70V PWM CONTROL FROM n ECPM03 E — NOTES WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED K - PINK WH - WHITE RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT " n nA 0 E 1 rl px NICK[ 3 LI n 75 n I 17 0 3 `D CuCDw CO i 0F\) s Q� o > Q Ln s C5 x w o r-, 75 L -4- O o F_ N 75 Cu W DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L — R 8 5 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 6 F.T.F.(''TPTr.'AT. P,4('K,4(T'F — .Tnpm.57im. n REVISIONS DESCRIPTION I DATE: SWITCHES FANS CONTROLLED NO TAG PACKAGE # L❑CATI❑N ❑PTI❑N L❑CATI❑N QUANTITY FAN TAG TYPE iti HP VOLT FLA UTILITY CABINET 1 LIGHT KEF-1 EXHAUST 3 2.000 208 7.3 1 DCV-1111 UTILITY CABINET RIGHT RIGHT SMART CONTROLS DCV HOOD # 1 MAU-2 SUPPLY 3 2.500 208 5.7 1 FAN JOB NO MODEL NUMBER DRAWN BY SCHEMATIC 1YPE DESCRIPTI❑N ❑F OPERATION; JOB NO MODEL NUMBER DRAWN BY DCV-1111 INSTALL Demnnd Control Ventilation, w/ control for 1 Exhaust Fan, I Supply Fan, Exhaust on In Fire, Lights out In Flre, Fans DCV-1111 6571705 modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature 6 5 7 1 7 0 5 JOB NAME DATE DWG NO sensor shipped loose for field Installatlon.Verify distance between VFD and Motor) addltlonnl cost could apply If JOB NAME DATE Kuzma's Expanslon - Edmonds W... 1/22/2024 ECP #1-1 distance exceeds 50 feet. I Kuzma's Expanslon - Edmonds W 1 1/22/ 1 2 BREAKER PANEL TO PRIMARY CONTROL PANEL 3 ResponslblUty, Electrlclan BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED _ BREAKER PANEL PRIMARY CONTROL PANEL 4 —Hat MFEA2KER 1PH — Neutral V Ground 5 15 A CONTROL POWER DO NOT WIRE GND TO GFCI OR SHUNT TRIP BREAKER. 6 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 LINE L1 7 BREAKER 3PH —LINE L2 208 V LINE MCA, 9,1 A Ground GND 8 MOCP, 20 A EXH-1 SM-1 WIRE TO VFD QUICK CONNECTOR 9 10 BREAKER PANEL TO FANS _ Responslbllltyl Electrlclan 11 BREAKER PANEL FANS _ LINE _ 12 BREAKER 3PH _ LINE _POWER TO 208V _ LINE _FAN _ MCAi 8.3A Ground _ 13 MOCP, 15A MAU-2 14 15 CONTROL PANEL TO FANS Responslbllltyl Electrlclan i6 PRIMARY PANEL FANS LOAD LEG I FAN, 01 EXH-1 _ Load Wiring UI �% 10.3 17 SM-1 Vl LOAD LEG 2 Rio HIP, 2.000 VOLT-208 V WIRE TO I L _13 3 VFD QUICK EGRD GnouND 18 CONNECTOR WIRE TO MUST HAVE ITS OWN CONDUIT DISCONNECT DO NOT SHARE CONDUITI 19 FEED STP THROUGH INNER RP TO RD COOLING TUBE. ALLOW FOR NIDEC MOTOR PWM ENOUGH SLACK ON STP FOR 13K TO GR MOTOR — SPEED SIGNAL PROPER HINGING. (EXHAUST ONLY) TELCEI 20 NOTE, PWM SIGNAL IS POLARITY BK TO YW ECM-01 SENSITIVE. ZIEHL MOTOR UU77 RR RRpp77 BK TO BK _ CONTROL SHIEQDEBDQWISTE�DPAIR MAU-2 Y1 PANEL TO PIA �"— r, DQ ECM P1B u ---�� ACM-5 — FAN, 02 22 24VAC FAN START $F❑1 24V SIGNAL SFCI 24Vna UIw 23 TO MUA BOARD WIRE TO UNI MAU-2 INTERLOCK 24 REMOVE JUMPER 1 2 MAKE UP AIR [IN N PCB MUA ZONE 1 CONTROL PANEL COMMON CONTROL PANEL TO FIRE SYSTEM DAMPER ILIA D3 NORMALLY OPEN PROVING IL1B �Il� DRY CONTACT 1 Res onslblllt p Y , CERTIFIED INSTALLER INTERLOCK LOW VOLTAGE CONNECTION FOR TERMINAL NAMES ON/OFF WITH F COMMON 3 CONTROL PANEL COMPONENT DAMPER INTERLOCK. WIRE ➢O NOT APPLY SUPPLY FAN SF02 NORMALLY OPEN MULTIPLE SUPPLY ON THE SAME 6 MUA BY OTHERS GROUP 1 SPARE CONTACTS WILL MAKE ZONE IN SERIES. SHOULD COMMON TO NORMALLY OPEN 4 FIRE STATS HAVE CONTINUITY WHEN DAMPER WHEN SUPPLY FAN IS ON, IS PROVEN OPEN. NOT REQUIRED FOR ALL UNITS. FS-01 SEE MAKE-UP AIR SCHEMATIC. DCV SPEED V + + - 5 CONTROL PANEL FIRE STAT SUPERVISED LOOP May be factory field W - 0-lOV OUTPUT - TO BIAS TO DUCT mixed and wiring. See Installation Schematic. Fire Stat ON P ON PCB WIRE TO ECPM03 TERMINALS. Multiple fire sensors possible. CONFIGURABLE OUTPUT. MOUNTED FIRE HIGH TEMP WIRE (842 F), PNi (TOTAL) SEE ECPM03 OWNERS MANUAL. 6 DETECTION SLPCON-xFT required for all FS-02 CONTROL PANEL TO ACCESSORY ITEMS VFD ANALOG 30 + STAT(S) Supervised Loop wiring In contact with a hood. All other wiring shal W - TO BMS be PN 6320UL, Belden or slnllar. Fire Stnt Responslbllltyl Electrlclan 0-10V OUTPUT2 7 IN VFD WIRE TO VFD TERMINAL STRIP, 4 CONTROL PANEL COMPONENT PROPORTIONAL TO FREQUENCY, (EACH VFD> SEE VFD OWNERS MANUAL. BMS SW���_^�ITNNNNII..11C��p��pH 8 PULL STATION CONTROL PANEL ALL SWITCHES FACTORY WIRED CONTROL PANEL I �/01 TO `14 CAT-5 CONNECTION SWITCHES EXTERNAL SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE) FANS AND 9 SYSTEM LOOPAnorl �ooP i 2FMUTF FIRE Mlero SW SWITCH LIGHTS Mult�Ple annual a�tuatmn Poss�dle, HOOD LIGHTS 1 10 CONTROL PANEL tip M Ptu le annual actuation possible, Ag junper with wires fron pinl to P1n4 and from pine to pin3 is mounted a AUX-Dl CONTROL PANEL $1 BLACK y� r GAS SOLENOID TO FIRE noe oM the jumpers and loop, In the MSPOFAI s d l.h.1 I'm Mi�roswro�h Ms-ol is optional for fire Adjacent TO I —WHITE �"' POSITIVE TO GAS VALVE SYSTEM PULL Yst" interlo�i FS GREEN J CONTROL PANEL LGV � Panel HOOD LIGHTS WIRE TO J-BOX ON TOP OF HOOD TO N1D _NEGATIVE 11 STATION aux�Ua y Intorlock (aux-m), 1400 W MAX ONLY ENERGIZED THROUGH LCD Were ACT / AU2 of adjacent Master FS 1, in loopiSLln MAD-01 GAS VALVE HMI WHEN FIRE SYSTEM ARMED. paneus, each annual uotivo.tion e ch a�ro���a.,t, See Fire for sum) del CONTROL PANEL IA 24V DC ONLY GAS VALVED IF USING 120V 12 system drawings for more information, M0.nU0.l TO L Actuation WIRE T� CONTROL BARD, INSTALL ROOM TEMP 1 Device ROOM TEMP SENSOR IN ROOM AWAY FROM HEAT GROUPS, CONTROL PANEL T❑ FIRE SYSTEM SENSOR SOURCES. DO NOT INSTALL SENSOR 13 ON THE CEILING GRID, SEE MANUAL, ResponslblUty, ALARM CONTRACTOR ECPM03 CORE PCB CONTROL PANEL[TaAa CONTROL PANEL COMPONENT 14 CAT-5 CONNECTION CONTROL PANEL TO FACTORY WIRED TEMPERATURE HOOD 1 BUILDING TO `13 ADDITIONAL DEVICES MAY BE INLINE, `15 CAPTURE VOLUME SENSOR. MOUNTED IN HOOD CAPTURE CAPTURE I ALARM PANEL MASTER FS PLACE END OF LINE PLUG SENSOR VOLUME, CONTROL PANEL FIRE INPUT 15 BOARD, IN EMPTY JACK, PNi EOL120A EO 20A J6 J9 UNLESS VFD, PCU, SIGNAL FOR AL1 � OR OTHER COMPONENT IN SERIES, CONTROL PANEL BUILDING AL2 18 TO T3B FIRE ALARM --------- WIRE DIRECTLY TO CORE CIRCUIT INTERLOCK NETWORK MASTER CORE PSP SENSOR WIRE T� CONTROL BOARD, HOOD 1 PSP TEMP PANEL BOARD. AL1 WILL MAKE AL2 IN FIRE CONTRTOPANEL SHIELDED TWISTED PAIR BLACK SENSOR MOUNTED IN SUPPLY PLENUM. CONDITION. CB V RED 17 CB GAS SOLENOI BUILDING ALARM PANEL MASTER FS EZCWIRE SHIELD TO LIKE TERMINALS IN ALL CONTROL PANEL GA$ HOT TO GAS VALVE CONTROL PANEL PANEL CORE PANELS THAT MUST ACTIVATE TO 1 NEUTRAL SIGNAL FOR COMMON i6 TOGETHER, SET MASTER & SLAVE BUILDING TBC DIP SWITCHES PER FIRE SYSTEM GAS VALVE ONLY ENERGIZED THROUGH LCDNORMALLY C MANUAL. 120V ONLY HMI WHEN FIRE SYSTEM ARMED. TROUBLE TBL TROUBLE RELAY CONTACTS �DOSED _ ALARM MAKE TBC TO TBL IN TROUBLE 19 CONDITION. THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE 40 SPECIFICATIONS SHUNT COIL CONTROL PANEL HOT TO SHUNT COIL 21 SIGNAL FOR ENM - — NEUTRAL FROM SHUNT COIL EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. 22 ONTAC TpR_COI CONTROL PANEL K$ HOT_TO_CONTACTOR_COIL �� SIGNAL FOR NI NEUTRAL_TD CONTACTOR COIL � 23 EXTERNAL KS TERMINAL IS DE -ENERGIZED CONTACTOR COIL IN FIRE CONDITION. 24 JOB NO MODEL NUMBER DCV-1111 6571705 JOB NAME Kuzma's Expansion - Edmonds W... 1 TANK PROTECTION ELECTRICAL DETAIL 2 ELECTRICIAN, 1, WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC _ 2, WIRE ALL FANS PER INCLUDED SCHEMATIC 3 3, WIRE SHUNT TRIP BREAKER (OPTIONAL) 4, WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5, WIRE GAS VALVE 4 5 6 7 8 BY SCHEMATIC TYPE DESCRIPTI❑N ❑I- ❑H INSTALL Fire System #1 TANK FS - 4.0/4.0. DWG NO 02/10/2021 Rev. 2 FS-1: MASTER ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL) ST & N1 BREAKER COIL (Al & A2) 120 VAC ( 4 AMPS ST TO Al ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & NI + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL) KTS & NI KTS & NI 120 VAC ( 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL) AU1, AU2 SOLENOID 120 VAC ( 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & NID (IF 24 VDC) GAS & NI (IF 120 VAC) RED/RED/GREEN 24 VDC DR 120 VAC ( 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED NI TO RED QND GREEN TO GROUND 9 10 11 12 13 SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES 120VAC 14 -ST TO Ai ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER 15 16 17 18 POWER TO ELECTRIC APPLIANCE 19 20 21 22 23 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN ELECTRIC II GAS COOKING — APPLIANCE(S) 24 — NOTE, SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1 GROUND -POWER MUST NOT OkIGINATE FROM SHUNT TRIP BREAKER 1 r JOB NO I MODEL NUMBER DCV-1111 IIRAWN BY I I 6571705 DATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 JOB NAME Kuzma's Expansion - Edmonds W... 1/22/2024 TANK PROTECTION LOW -VOLTAGE DETAIL ALARM CONTRACTOR, I, WIRE MANUAL ACTUATION DEVICES) REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2, COMPLETE FINAL HOOKUP OF SYSTEM 3, VERIFY FINAL FIRE SYSTEM TEST SCHEMATIC TYPE DESCRIPTI❑N OF ❑PERATI❑N, INSTALL Demnnd Control Ventilation, w/ control for 1 Exhaust Fan, I Supply Fan, Exhaust on In Fire, Lights out In Fire, Fans DWG NO sodulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature nsor shipped loose for field Installatlon.Verify distance between VFD and Motor) addltlonnl cost could apply If ECP #1-2 distance exceeds 50 feet. SCHEMATIC TYPE DESCRIPTI❑N ❑I- ❑PERA I I❑N, INSTALL Fire System #1 TANK FS - 4.0/4.0. DING NO ECP #1-4 10/01/2023 Rev. 3 FS-1: MASTER ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS 101 AND 104 WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 MANUAL ACTUATION DEVICE(S) 102 AND 103 1 & 2 24 VDC ( 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 BLACK AND WHITE 24 VDC ( 1.0 AMPS WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 22 AND 23 HIGH TEMP (842'F) #441601CISFE9 (WHT) & #441601C6.FEO (BLOWIRE OR SIMILAR ONLY IF RAN OF HnnDi OTHERWISE BELDEN #63POUL OR SIMILAR PLENUM RATED WTRFi SEE FTMIRF I FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE (AC/DC) CORE ELECTRICAL CONTROL PANEL CORE INTERLOCKS) CA, CB, CC CA, CB, CC RS-485 COMMUNICATIONS CORE SYSTEM (1) CA, TO CORE SYSTEM (2) CA, CORE SYSTEM (1) CB, TO CORE SYSTEM (2) CB. SIGNAL CORE SYSTEM (1) CC, TO CORE SYSTEM (2) CC, USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, T❑K VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL 0.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 SUPERVISED LOOP -4 WIRES 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP - -USE HIGH TEMP (842'F) #44160106FE9 (WHT) & #44160106FE0 (BLK)WIRE ONLY IF RAN OVER TOP OF HOOD1 OTHERWISE BELDEN #632OUL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN / COOKING c APPLIANCES) — ATTENTIONI LOW —VOLTAGE DC OR SIGNALING WIRE SH BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOUF NOTE, SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS FIRE ALARM PANEL CORE INTERLOCK 2 WIRES + SHIELD — — — — — — -SEE FIGURE #3 8760 OR SIMILAR WIRE F— — — — — — — — — — — — CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL ARE, MANUAL NETWORK WITH VALID INTERNET ACCE ACTUATION I VIA ETHERNET SWITCH OR WIRELESS DEVICE ROUTER 10 TO 20 !EXHAUST HOOD FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE -SEE FIGURE IA 42 TO 48 INCHES ABOVE FLOOR MANUAL ACTUATION DEVICE LEVEL TO PART #SS2031ZA-EN ELECTRIC GAS CENTER OF PUSH PROTECTIVE COVER MUST BE INSTALLED STATION RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 4% M Pq Ez I � -P Ln IOU O 3 �O 75 L�J Q� CmD TW Q) _0 Q s Q 3 C5 x W 0 75 O L� CD E N 75 �I � � W DATE:1/22/2024 DWG.#: 6571705 DRABW1N JL — R85 SCALE: 3/4)) = 1'-0" N_ N N O O O N_ N <n N It W Z O _ OL O N 00 O >Q N L N > W G) Q U •U M OL O O ce) MASTER DRAWING SHEET NO. 7 REVISIONS DESCRIPTION I DATE: JOB NO MODEL NUMBER _lilt DRAWN BY SC IEMAnC TYPE DESCRIPTION OF ❑PERATI❑NI 6571705 Fire System #1 TANK FS - 4.0/4.0. JOB NAME DATE DWG NO Kuzma's ExpQnslon - Edmond W... 1 TANK PROTECTION LOW -VOLTAGE FIGURES 10/01/2023 Rev, 17 2 3 FS-11 MASTER 4 USE BELDEN #6320UL 5 OR SIMILAR WIRE J2-1 J10-1 6 J2-2 J10-2 MICROSWITCH/ MANUAL 7 FIRE ACTUATION DEVICE STAT-1 IY� O-WH BUILDING CONTROL BREAK WIRE BK-C (OR RD) BREAK WIRE BK-C 1 2 R RD) FIRE ALARM PANEL 6 BEFORE BEFORE MANUAL FIRE ALARM INSERTING INSERTING ACTUATION CONTACT INTO FIRE INTO DEVICE 9 TERMINALS STAT-2 No TERMINALS BK-C �✓ O-WH BK-C (OR RD) 1 2 R RD) flA END ALARM 10 INPUTLINE DEVICE J2-3 10-3=�_r 11 J2-4 J10-4 12 WIRING CONNECTIONS WIRING ALARM CONTACTOR FIRE FOR FIRESTAT LOOP WIRING CONNECTIONS FIGURE 2 FIGURE 1 FOR MANUAL ACTUATION LOOP FIGURE IA 13 14 BUILDING 15 FIRE ALARM CORE CONTROL SUPERVISION SUPERVISION SUPERVISION SHIELDED TWISTED PAIR TROUBLENCONTACT SWITCH SWITCH SWITCH 16 CA BK BK 0 17 RD RD TROUBLE TOK TBL NO NC 1 2 1 2 END INPUT OF LINE 8 TBC C C C DEVICE WIRING CONNECTIONS 19 FOR CORE INTERLOCK FIGURE 3 20 WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 21 22 23 ATTENTIONi LOW —VOLTAGE DC OR SIGNALING WIRE SHOULD NOTEi SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 24 MOTOR POWER CIRCUITS. SEE INSTALLATION DIAGRAM FOR FIELD WIRING REQUIREMENTS. 1 • MTRIEXH-1 14 AWG FLA17:3 3 PH BK O BK U/Tl HP12000 P100101 — 208 V BK BK V/T2 W/T3 e!R P1011N/A 20 A P10210.0 GND GR BK HK L1 '10317l.8 P107100 BK BK L2 P108176 P1311N/A 2 W BK HK L3/N P150101 O P167171.8 V FD, ESV222NO2YXH571P1941225 P410111 3 4 5 6 7 8 9 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 DCV Rev, 2.10.00 HMI Rev, 2.10.00 RA-x RD-x 120 VAC 24 VDC RELAY RELAY NO 4 3 NO ff NCNCCOIL 8 7 COILOM 6 5 COM T-X starter PM varies o-X Contact- _ PNI a" SM-X VFD PN arles LR-X Line/Load Reactor PN: varies LEGEND —FIELD FIELD WIRING FACTORY WIRING BK- BLACK YW- YELLE`.. BL- BLUE GY- GREY BR- BROWN PR- PURPL- OR- ORANGE RD- RED WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD ALP RE PD/GN- RD/UN STRIPE diti WH/BL STRIPE 1 2 RD 18A 3 3x RD RD 4 RDSW-05-30R Test Armed RD RD-17 BR — Fire Relay rJ L R 6 RDBK FIRE IN ICATOR 0 RD'pp — Audible Alarm Prime / Reset PS-1 RD n�OR WH J� Pressure Switch 7 q RDSW-0 BR Door Tamper Switch 16AWG o PN, 1606-XLP-60EQ LN. Adjust power supply to 27.5 PS-02 6OW Volts with an accurate Digital Volt Meter or with an HMI plugged Into the CORE +- board. 8 RD-20 Equipment Relay RD ODOR/BL TroublelRelay — RD KKllO kkii OR/BL AuxlLlary Interlock Relay 9 To Bullding Fire Alarm Panel — FIRE ALARM SYSTEM DRY CONTACTS. Termlals AL1 & AL2 make In FIRE. + R1 5 AMP FUSE 10 DISCONNECT JI 24 VOLT BATTERY PACK FOR SHIPMENT + III PCB-2 J3-8 Tert 0 Tet FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 RA-x 120 VAC RELAY NO 4 3 NC 2 1 COIL 8 7 COM 6 5 ST-X Starter PN, e OL-X Dverioead PN, a C-X C.htt.,t.r PN, vQrws PS-1 Power Sup. 241DC PN M➢P18-24A-IC RA-x 120V Relayy DPDT PN; 3411001840 RD-x 24VDC Ligght Relay PN: 3411001380 TS-x Duct Thermostat PN: A/IP-PO-T4°-EXPL ' —FIELD WIRING FACTORY W1RiNG BK- BLACK YW- YELLOW BL- BLUE GY- GREY BR- BROWN PR- PURPLE UR- ORANGE RD- RED WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE JOB NAME Kuzma s Ex ansl-, npew,ur. nnc Demand control Ventllatlon, w/ control for I Exhaust Fan, 1 Supply Fan, Exhaust on In Fire, Lights out In Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE M13TDR REQUIRED FOR USE WITH D. Room temperature se nsor shipped loose for ATTENTIONi LOW -VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE C❑NDUIT FROM ALL AC SOURCES, FS-11 MASTER G PKr rI RD RD TERMINAL LGV USED FOR 24VDC POWE 24V DC Gas Valve RED GAS VALVES ONLY, GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. BR HIGH TEMP WIRE (842 F), PN, SLPCONi required H for pF�S-�0111R�.I��� wl Supervised wiring In contact with a FIRE STAT SUPERVISED Loop oW hood. All other wiring May be mixed factory and field Fire Stat shall be PN, 632OUL, wiring. See Installation Schematic. Belden or similar. Factory Multlple fire sensors possible. FS-02 mounted hood sensors will W be terminated at Junction box on top of hood. B J Fire Stat I R R� I Auxlllary Interlock (AUX-01) MS-01 1 Wire AUl / AU2 of adjacent Master CORE panel(s) In each manual activation loop B for simultaneous activation. Micro SWMANUAL ACTUAUI/AU2 will have continuity for 10 SYSTEM LOOPATION LOOP / REMOTE FIRE 0 1 seconds If adjacent panel goes Into fire Multlple manual actuation possible. "AUU1�2J; condition, activating this CORE Panel but A Plug jumper with wires from pinl to allowing for a reset after 30 seconds. pin4 and from pin2 to pin3 should be d,Jacen mounted on J30 If there Is no manual CORE NOTE, AUl/AU2 terminals of CORE Panel actuation device and no microswltch. Panel should not be wired Into Its own manual uAD-01 activation loop. H -11 Manual R Actuatlon Deulcce- g -I CAT-5 WIRING (MASTER ONLY) _9 ECPM03 WIRED IF REMOTE PREWIRE ECPM03 PUT END OF LINE PLUG IN EMPTY RJ45 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. SHIELDED TWISTED PAIR IR BKCA RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or RD CH Communication Module. See Installation Schematic for Connection. N Master CORE totCLOSED D DIP Switch Posltlon Slave mpppmnoa� OPEN CORE with address 1 set DIP SW 8 to CLOSED position, All other CORES 1 2 3 4 5 6 7 8 set DIP SW 8 OPEN. FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxillary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low SO Battery Voltage Low 11 AC Power Fallure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood In Interlock Network 16 Fault on PCU In Interlock Network FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION RA-.N. 0 VAC 24B DC RELAY RELAY NO 4 3 NO 4 3 NC 2 1 NC 2 1 COIL 8 7 COIL 8 7 COM 6 5 COM 6 5 NAB-01 MANUAL ACTIVATION PN: DEVICE PCB-2 CORE PER PN PCBCORE-APP 'S-02 CORE POWER SUPPLY PN: 1606-XLP-60E WS-x Water Solenoid PN vQrles -T-06 24V Red Ind. Light PN PNL-1163-OUR -L-01 Surf Level Sensor PM A05510 4A-Ol Audible Alarm PN SCE120LA3FPIB PB-XX Prime/Reset Switch P4 7 B4BA2/2B4BZ1015 SW-05 TEST/ARM Switch PN ZB5AD2 SW-04 Tamper Switch PN: BZ-2R01-A2 SP-1 Surfactant Pump PN: 50000-805 GV-1 24, DC Gas Valve PN: vorles FS-XX Duct Fire Sensor PN: 12-F28021-000360 LT-05 24V YLW Ind Light PN: PNL-1163-DUY 'S-01 Remote Pulil/Push PM Station STI-SS2431 'WS-01 24VDC Power Suppl PN 24VDC 18W POWER RD-XX 24VDC Phoenix Relay A PLC-RPT-24➢C/21 'S Pressure Switch PN EWC-PRESSURE LEGEND —FIELD FIELD FACORY WDZDJG BK- BLACK YW- YELLOW BL- BLUE GY- GREY BR- BROWN PR- PURPLE W-<- ORANGE RD- RED H- WHITE GR- GREEN OR/BL- UR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/UN STRIPE WH/BL- WH/BL STRIPE RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT n 4% v � L I W O 3^DI \\CD 75 L�J W TW W O - > /r \� s / r 3 d S 1 x W o r--, 75 d 't O L� O E N 75 l V W DATE:1/22/2024 DWG.#: 6571705 DRABW1N JL — R85 SCALE: 3/4" = 1'-0" N_ N N Li> N_ N Ln N 7 W Z 0 _ OL CD N 010 >Q N W 0) Q U U (0 OL 0 C•M MASTER DRAWING SHEET NO. 8 REVISIONS Dl111urelaIeSeI.IaI10111MTJNaIIIIWIN IIII I■:i.I.IeSyIIaI10111mWHEN �►y,K"I*[ilellIIII11[►11 CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATI❑N SYSTEM TURNDOWN REQUIREMENTS ❑UTLINED IN IECC 403.7.5 (2021). DUCT THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATI❑N INSIDE OF THE EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL OR PAINTED STEEL. TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISERS) SHALL BE CONSTRUCTED OF STAINLESS STEEL. / A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED I ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTI❑N SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE I FANS AFTER THE C❑❑KING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST SYSTEM IS REDUCED, A DIGITAL CONTROLLER SHALL PR❑VIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN TEMPERATUI SENSOR, CYCLING. ENS VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PR❑VIDED FOR FANS AS REQUIRED, THE DIGITAL CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETP❑INT AND A MAXIMUM SETPOINT ON DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO CALCULATE THE SPEED REFERENCE SIGNAL, THE VFD SPEED RANGE OF ❑PERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATI❑N REQUIREMENTS, AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED PR❑P❑RTI❑NAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT C❑❑KING LOAD OR COOL DOWN MODE WHEN SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER C❑❑KING ❑PERATI❑NS HAVE COMPLETED. ❑PERATI❑N DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PR❑VIDE AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATI❑N REQUIREMENT. TYPICAL HOOD CONTROL PANEL INSTALLATION SEQUENCE OF ❑PERATI❑NS: THE HOOD CONTROL PANEL IS CAPABLE OF ❑PERATING IN ONE OR MORE OF THE F❑LL❑WING STATES AT ANY GIVEN TIME: - AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A C❑NFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB C❑NFIGURATION EACH FAN ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE WITHIN A USER -DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATI❑N SYSTEMS ARE CAPABLE OF M❑DULATING EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS ❑UTLINED IN IECC 403.7.5 (2021). - MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION - SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE IS DETECTED ON A COVERED HOOD. DAY, THERE ARE THREE ❑CCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED ❑CCUPIED TIME, THE SYSTEM WILL RUN A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). TIME, DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING ❑CCUPIED. 0 n 0 0 E - AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES: A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. - OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (N❑ RESET RELAY REQUIRED). HARD -WIRED INTERLOCK), C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION, D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION, - FIRE: UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR E. MIS -WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION, CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION, ACTIVATING THE SHUNT TRIP BREAKER PR❑VIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS, MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT m pq Cpx I � _p 0 3 �0 pj CDw CO I 0F\) s QJ _o � Q s x w o 75 v1 � c5 -4- O E7 o E N 75 Cu W DATE: 1 /22/2024 DWG.#: 6571705 D RABW�N J L — R 8 5 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. I DUCTWORK #> PARTS - JOB#6571705 DOUBLE WALL DUCT MIWO@O@H@ TAG PART # CFM GPM ZONE C❑VEREDBY SP WEIGHT VEL❑CITY QTY DESCRIPTI❑N DOUBLE WALL RISER COVER - USED ON 16' INNER RISER, 4" LONG - 2 LAYERS REDUCED HI -El DW20DWRISER-2R-S 2500 -0.909 8.36 0.00 1 CLEARANCE - 20' STAINLESS STEEL OUTER RISER SHELL ASSEMBLY. INCLUDES INSULATI❑N & SINGLE V CLAMPS FOR INNER & OUTER C❑NNECTI❑NS. P1 DW1645DWASY-2R-S 2500 -0.0525 22.06 1790,49 1 DOUBLE WALL DUCT - 16' INNER 45 DUCT - 2 LAYERS REDUCED CLEARANCE - 20' STAINLESS STEEL OUTER SHELL. P2 DW1647DWLT-2R-S 2500 -0.02 70.12 1790.49 1 DOUBLE WALL DUCT - 16' INNER DUCT, 47' LONG - 2 LAYERS REDUCED CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. DUCT - H❑RIZ❑NTAL SADDLE SUPPORT KIT, USED WITH 20' ❑D - INCLUDES UNI-STRUT CUT P3 DW2024SADKIT 8.01 1 TO LENGTH, DW2024SAD, & HARDWARE BAG 4, P4 DWI6DWTEASY-2R-S 2500 1 -0.012 49.32 1790.49 1 DOUBLE WALL DUCT - 16" INNER TEE DUCT - 2 LAYERS REDUCED CLEARANCE - 20' ASSEMBLED W/P5 STAINLESS STEEL OUTER SHELL. P5 DWI6DWACCD❑❑RC❑V-2R-S 21.48 1 DOUBLE WALL DUCT - 16' INNER ACCESS DOOR & 20' ACCESS DOOR COVER WITH CLAMPS - 2 ASSEMBLED W/P4 ❑=T LAYERS REDUCED CLEARANCE - 20' STAINLESS STEEL OUTER SHELL. P6 DW1645DWASY-2R-S 2500 -0.042 22.06 1790.49 1 DOUBLE WALL DUCT - 16" INNER 45 DUCT - 2 LAYERS REDUCED CLEARANCE - 20' STAINLESS STEEL OUTER SHELL. P7 DW1647DWLT-2R-S 2500 -0.02 70.12 1790,49 1 DOUBLE WALL DUCT - 16' INNER DUCT, 47' LONG - 2 LAYERS REDUCED CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P8 DW164550DWLTTP-2R-S 2500 -0.019 68.55 1790,49 1 DOUBLE WALL DUCT - 16' INNER DUCT, 45,5' LONG - 2 LAYERS REDUCED CLEARANCE - 20' ASSEMBLED W/P9 STAINLESS STEEL OUTER SHELL - USED WITH TRANSITI❑N PLATE. P9 DW2616TP 2500 11.62 1790.49 1 DUCT TO CURB TRANSITI❑N, 26-1/2' CURB TO 16' DUCT, 16 GA ALUMINIZED. USED ON BDU18, ASSEMBLED W/P8 ❑=B SYSTEM AT P9 -1.0835 0.00 DOUBLE WALL RISER COVER - USED ON 16" INNER RISER, 4" LONG - 2 LAYERS REDUCED RC1 DW20DWRISER-2R-S 8.36 1 CLEARANCE - 20' STAINLESS STEEL OUTER RISER SHELL ASSEMBLY. INCLUDES INSULATI❑N & SINGLE V CLAMPS FOR INNER & OUTER C❑NNECTI❑NS. 3M-2000PLUS 0.80 2 DUCT - 3M FIRE BARRIER 2000 PLUS SILIC❑NE - USED AS SEALANT TO SEAL DUCT J❑INTS. DWI6DWCLASY-2R-S 7.96 5 DUCT - 16' DUCT - 20" DOUBLE 'V' CLAMP - 2R INSULATI❑N & SINGLE 'V' CLAMP INCLUDED - REDUCED CLEARANCE. TOTAL WEIGHT 401.46 DOUBLE WALL FACTORY BUILT DUCTWORK - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATI❑N AND ❑PERATI❑N MANUAL - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16' PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE C❑LLECTI❑N RESERV❑IR. - WHERE H❑RIZ❑NTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16' PER LINEAR FOOT. H❑RIZ❑NTAL DUCT DIAMETER SUPPORT SPACING (FT) 5' 7' 6" 7' 7' 7' 8' 7' 10" 7' 12' 7' 14' 7' 16' 7' 18' 5' 20" 5' 22" 5' 24' 5' 26" 5' 28' 5' 30' 5' 32" 5' 34' 5' 36" 5' VERTICAL TYPE WALL SUPPORT (FT) CURB SUPPORT (FT) FLOOR SUPPORT (FT) 2R & 2R HT (5"-16") 20' 24' 24' 2R (18') 18, 24' 24' 3R & 3Z (5'-24') 10, 24' 24' 3Z (26" -36") 10, 20' 20' D❑ NOT LEAK TEST USIN❑ SM❑KE BOMBS C❑NTAININ❑ CHLERINES/CHU❑RIDES CONSULT WITH CAPTIVEAIRE FOR PROPER LEAK TESTING METHODS, DUCTWORK DUCT #1 TOP VIEW I DUCTWORK #1 FRONT VIEW DUCTWORK #1 SIDE VIEW DUCT DUCT 9c 28,50" n n 102.96' i 28.50' RECEIVED Jan 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 0 Ift 1 17 W r f 0J 0J i O 75 't O o E 75 Cu W DG1412o 1 /22/2024 M&M-0 6571705 DGQ JL — R85 C�J�L"11S�o 3/4" = 1'-0" UL HEU MOo 10