APPROVED FIR FIR2024-0008+Fire_Alarm_Plan+1.29.2024_3.26.36_PM+4026622SCOPE OF WORK: KU MA' FISH MARKET NEW FIRE ALARM SYSTEM FIRE ALARM SYSTEM TENANT AREA OF WORK 3)855 S.F. 21104 70TH AVE W. EDMONDS, WA 98026 BUILDING SPRINKLER STATUS: N/A 1 - JAQUALIS 21 Qth St SW PorbLn Repair 19 9 Edmonds Public Works fames Auto Services Kafe Neo Edmonds Greek • SS Kuzma's Fish Market i 50 2121h St SW 212111 St SW w INPUT/OUTPUT MATRIX SYSTEM INPUTS 1 MANUAL PULLSTATION ATFACP 2 AREA HEAT DETECTORS 3 ANSUL HOOD 5 FIRE ALARM AC POWER FAILURE 6 FIRE ALARM SYSTEM LOW BATTERY 7 OPEN CIRCUIT 8 GROUND FAULT 9 NOTIFICATION APPLIANCE CIRCUITSHORT 10 11 q0 V- Mackin the BOX Double Bonus 9 Jac�$599 212th St VICINITY MAP CONTROL UNIT ANNUNCIATION O� OPT \�O OOP SYSTEM OUTPUTS NOTIFICATION SUPPLEMENTARY Z� 50�0\� P O1 JQOQ. 5J�0 QO�J� P��O AC\O7 �\O�P \O�P� JS O�' PLO `OCJ �O�O Cl) J��'OQ� 5 OAP OQS 0�5 9JQ�Q� SRO SOS O�� ��`�<1 A B C D E F G H I J K L X X X X X X 1 X X X X X X 2 X X X X X X 3 X X X X 5 X X X X 6 X X X X 7 X X X X 8 X X X X 9 10 11 A B C D E F G H I J K L DRAWING INDEX 1 TITLE SHEET 2 FIRE ALARM PLAN 3 LOAD CALCULATIONS/RISER DIAGRAM BILL OF MATERIAL QTY DESCRIPTION MANUFACTURER PART NO 1 FIRE ALARM CONTROL POTTER IPA-60 PANEL MAIN BOARD FOR IPA-60 1 FIRE ALARM CONTROL POTTER IPA-60 MAIN BOARD PANEL 5G LTE-M SOLE & DUAL PATH CELLULAR 1 COMMERCIAL FIRE POTTER INTELLICOM-5GV ALARM COMMUNICATORS ADDRESSABLE PULL 3 STATION SINGLE ACTION POTTER PAD100-PSSA 1 SINGLE INPUT MODULE POTTER PAD100-SIM HEAT DETECTOR WITH 6" PAD300-HD 9 POTTER STANDARD BASE W/PAD300-6DB HORN STROBE, 24 VDC, 1 POTTER HS-24WW WHITE OUTDOOR HORN STROBE, FIXED 75 1 CANDELA, STANDARD POTTER HS-24WW-WP ENCLOSURE, WHITE 2 HORN STROBE, CEILING, POTTER CHS-24W WHITE 2 STROBE, CEILING, WHITE POTTER CS-24W 3 STROBE, 24 VDC, WHITE POTTER S-24WW OUTDOOR STROBE, 1 FIXED 75 CANDELA, POTTER S-24WW-WP STANDARD ENCLOSURE, WHITE DEVICE LEGEND SYMBOL QTY MANUFACTURER PART NO DESCRIPTION MOUNTING FACP 1 POTTER IPA-60 FIRE ALARM CONTROL PROVIDED W/ PANEL PANEL MAIN BOARD FOR IPA-60 1 POTTER IPA-60 MAIN BOARD FIRE ALARM CONTROL PROVIDED W/ PANEL PANEL 5G LTE-M SOLE & DUAL PATH CELLULAR CELL 1 POTTER INTELLICOM-5GV COMMERCIAL FIRE PROVIDED W/ DEVICE ALARM COMMUNICATORS ADDRESSABLE PULL F❑ 3 POTTER PAD100-PSSA SINGLE GANG BOX STATION SINGLE ACTION AIM 1 POTTER PAD100-SIM SINGLE INPUT MODULE 4" SQUARE BOX OR DOUBLE GANG BOX PAD300-HD HEAT DETECTOR WITH 6" SINGLE GANG BOX OR 3" 0 9 POTTER W/PAD300-6DB STANDARD BASE ROUND BOX 1 POTTER HS-24WW HORN STROBE, 24 VDC, 4" SQUARE DEEP BOX WHITE OUTDOOR HORN STROBE, FIXED 75 WP 1 POTTER HS-24WW-WP CANDELA, STANDARD PROVIDED W/ DEVICE ENCLOSURE, WHITE 2 POTTER CHS-24W HORN STIR CEILING, 4" SQUARE DEEP BOX C HBEE 2 POTTER CS-24W STROBE, CEILING, WHITE 4" SQUARE DEEP BOX OR C SINGLE GANG BOX 3 POTTER S-24WW STROBE, 24 VDC, WHITE 4" SQUARE DEEP BOX OR SINGLE GANG BOX OUTDOOR STROBE, FIXED 75 CANDELA, 1 POTTER S-24WW-WP PROVIDED W/ DEVICE WP STANDARD ENCLOSURE, WHITE CABLE AND WIRE LEGEND AW RESISTANCE LABEL PART NO G (4/KFT) DESCRIPTION TOTAL LENGTH A 18/2 FPLP/R (SLC) 18 7.77 2 COND. SOLID COPPER FPLP/R 257' ADDRESSABLE V 14/2 FPLP/R (NAC) 14 3.07 2 COND. SOLID COPPER FPLP/R ANALOG 288' UNSHIELDED General notes: 1.Scope of work: This project shall include the installation of a new addressable fire alarm system. 2.These drawings are diagrammatic. Refer to the architectural drawings for exact dimensions. 3,installation shall comply with NEC, NFPA 72 and all ether applicable codes as required by the local authority having jurisdictions. 4.Wiring depicted on these plans is schematic, actual wire locations may differ from these plans. Wiring shall be performed as actual building construction conditions allow and to minimize penetrations through area separation walls and fire rated wal Is. The use of a raceway is permitted as long as no 110 V or higher voltage cables are in the same raceway. 5.Final ratings shall be maintained fear all penetrations through fire rated construction. S.Power for all fire alarm panels and fire alarm power supplies must be provided by a dedicated AC branch circuit. The location of the branch circuit breaker shall be permanently identified at the control unit. Where a circuit breaker is the disconnecting means, an approved Breaker locking device shall be installed. For fire alarm and/or signaling systems, the circuit disconnecting means shall have a red marking. '.Power limited in non -power limited circuit wiring must remain separated in cabinet. All power limited circuit wiring must remain at least a quarter inch away from any non -power limited circuit wiring. Furthermore, all power limited and non -power limited circuit wiring must anter and exit the cabinet through different knockouts and or separate conduits. 8.When utilizing class A circuits, separate outgoing and return conductors of class a circuits by a minimum of 12 inches were run vertically and 48 inches were run horizontally. S.AII fire alarm cabling shalil be acceptable to the hire alarm equipment manufacturer for the intended purpose. 10.Smoke detector shall not be installed until after construction cleanup is completed and final. 11.1-ocate smoke detectors a minimum of 3 feet from mechanical supplies. Wall -mounted smoke detectors shall be located a minimum of 4 inches and a maximum of 12 inches from ceilings. 12.Provide synchronization of all visual notification appliance circuits. 131.Upon completion of the fire alarm system installation and programming, the installing contractor shall perform final testing of the entire system, per all applicable codes, and shall coordinate and perform a final fire alarm system inspection. 14.Provide offsite monitoring as required by the international fire code„ section 907.6.6 and the local authority having jurisdiction. 15.Installing contractors show physically label all initiating devices and notification appliance circuit end of limes (when wiring class B). These labels shal I be in place prior to start up in testing. CO fJk ';MC:NKF IXTE1"7If3H J FAP FIRE XARM JL P:L BPS "IN" 05,0 $IiRF�Y I THEMAL_ aETEG'T0R. I CELIi G CIF NC-t HrMki-9[I[7HF `IYMI�LL HOIIF1�1i15T1� 5' 42, FRjsir Ar_CE55 40' S4iD€ ACCESS Eqw ipmenit Mounting Elevations (TYPICAL) SeaCom FIRE & SECURITY 3014 Hcyt Ave. Everett, WA 98201 P: 425,317.8259 F: 425.317.8261 w callseacom.com m NICET o Kory Mehl NICET FAS III #160751 a. a a w a 0 z 0 z > O w F a_ O LU w 0 JE CV N GAO CN 6 o I I � bi co U) � O co E cfl z O O o M CAI a CD Y � � a m c W > 0 3 0 C 0 o ,s a UWcVo O U LLI Q CSC rn'� O CV CV t U ��< oLf�< LuO� LLJ C?C? JO ��J ��� ��QQ OEM j Cl: LL�LU Cn L 1J LU Cn Wcfl j O Q Cn j a) _U) Q� L�Of H o� �a Q �z o� IVLU CV Y LL W REFERENCE NUMBER: 1 TOTAL SHEETS 3 URI 01 oil 5 4 3 2 1 PANEL P1 (IPA-60) BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) PANEL POWER SUPPLY MAX CURRENT = 5A TOTAL USED CAPACITY (IN ALARM) = 1.34954A (26.99 %) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) CITY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL PANEL COMPONENTS Main Board for IPA-60 Fire 1 IPA-60 MAIN BOARD Alarm Control Panel 0.13 0.13 0.22 0.22 CIRCUIT SYMBOL CITY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) 5G LTE-M Sole & Dual Path Pl-1/01 (NAC) ceu 1 SLE-MAXVI-CFB Cellular Commercial Fire 0.085 0.085 0.2 0.2 Alarm Communicators Addressable Pull Station ED 3 PAD100-PSSA Single Action 0.0002 0.0006 0.0002 0.0006 P1•1-1 niM 1 PAD100-SIM Single Input Module 0.00024 0.00024 0,00024 0.00024 O 9 PAD300-HD Heat Detector with 6" 0.0003 0.0027 0,0003 0.0027 w/PAD300-6DB Standard Base Horn Strobe, Ceiling, White 2 CHS-24W 0 0 0.124 0.248 ��./C M C 2 CS-24W Strobe, Ceiling, White 30cd 0 0 0.12 0.24 Horn Strobe, 24 VDC, While 1 HS-24WW 30cd 0 0 0.063 0.063 P1-N1 2 S-24WW Strobe, 24 VDC, White 15cd 0 0 0.03 0.06 1 S-24WW Strobe, 24 VDC, White 30cd 0 0 0.035 0.035 1 S-24WW-WP Outdoor Strobe, Fixed 75 Candela, Standard 0 0 0.112 0.112 WP Enclosure, White 75cd Outdoor Horn Strobe, Fixed P1•N2 1 HS-24WW-WP 75 Candela, Standard 0 0 0.168 0.168 WP Enclosure, White 75cd TOTAL STANDBY (A) 0.21854 TOTAL ALARM (A) 1.34954 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.21854 24 1 5.24 SECONDARY ALARM LOAD (A) 1.34954 0.08 0.11 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 5.36 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 6.43 PROVIDE (2) 12V 8AH BATTERIES 'BATTERY BOX SIZE CAPACITY NOT SPECIFIED. REFER TO MANUFACTURER DOCUMENTATION. RISER DIAGRAM P1 FIRE ALARM CONTROL PANEL • H �3 DEDICATED 120V f�) 20 AMP CIRCUIT P1 •N2.01 EOL 5.1 k 75cd WP P1.1/01 (NAC)•01 EOL 5.1 k CELLULAR COMM • P1 1/01 (NAC) POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0 Min. Operational Voltage: 16 End Of Line Voltage: 20.4 Max. Circuit Current (A): 1 Voltage Drop Percent: 0.00 % Wire Resistance (Q/kFt): 3.07 Total Circuit Current (A): 0.2 Circuit Wiring Properties:'V 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 1 Spare Current (A): 0.8 Distance measured using drawn segment lengths with 10.00 %additional length calculated Total Circuit Resistance (Q): 0.005066 Spare Current (A) Percent: 80.00 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (12) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent Pl-1/0 1 (Ni EOL 5.1k SLE-MAXVI-CFB 5G LTE-M Sole & Dual Path Cellular Commercial Fire Alarm Communicators 0.2 0.2 1 0.005066 0 20.4 0 0.00% Calculation Methods: Resistance From Previous (Q) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (Q) x Remaining Current (A) P1 N1 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.45 Min. Operational Voltage: 16 End Of Line Voltage: 19.95 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 2.19 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.758 Circuit Wiring Properties:'V 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 195 Spare Current (A): 1.742 Distance measured using drawn segment lengths with 10.00 %additional length calculated Total Circuit Resistance (0): 1.197593 Spare Current (A) Percent: 69.68 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (0) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent P1•N1.01 S-24WW Strobe, 24 VDC, White 30cd 0.035 0.758 9 0.056679 0.04 20.36 0.04 0.21 % Pl-Nl-02 HS-24WW Horn Strobe, 24 VDC, White 30cd 0.063 0.723 0 0.002724 0 20.36 0.04 0.22 % Pl-Nl-03 S-24WW Strobe, 24 VDC, White 15cd 0.03 0.66 18 0.113056 0.07 20.28 0.12 0.59 % Pl-Nl-04 S-24WW-WP Outdoor Strobe, Fixed 75 Candela, Standard Enclosure, White 75cd 0.112 0.63 27 0.167044 0.11 20.18 0.22 1.10 % Pl-NI.05 CHS-24W Horn Strobe, Ceiling, White 30cd 0,124 0.518 16 0.097847 0.05 20.12 0.28 1.35 % PI-Nl-06 CS-24W Strobe, Ceiling, White 30cd 0.12 0.394 26 0.159539 0.06 20.06 0.34 1.66 % PI-Nl-07 CS-24W Strobe, Ceiling, White 30cd 0.12 0.274 32 0.197979 0.05 20.01 0.39 1.92 % Pl-Nl-08 S-24WW Strobe, 24 VDC, While 15cd 0.03 0.154 18 0.1095 0.02 19.99 0.41 2.01 % P1•N1.09 EOL 5.1k CHS-24W Horn Strobe, Ceiling, White 30cd 0.124 0.124 48 0.293225 0.04 19.95 0.45 2.19 % Calculation Methods: Resistance From Previous (Q) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) P1 N2 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.1 Min. Operational Voltage: 16 End Of Line Voltage: 20.3 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 0.47 % Wire Resistance (Q/kFt): 3.07 Total Circuit Current (A): 0.168 Circuit Wiring Properties:'V 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 92 Spare Current (A): 2.332 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Q): 0.566992 Spare Current (A) Percent: 93.28 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (12) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent P1•N2.01 EOL 5.1k HS-24WW-WP Outdoor Horn Strobe, Fixed 75 Candela, Standard Enclosure, White 75cd 0.168 0.168 92 0.566992 0.1 20.3 0.1 0.47 % Calculation Methods: Resistance From Previous (Q) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) Pl-Nl-04 Pl-Nl-05 P1•N1.01 P1•Nl-02 Pl-Nl-03 75cd 30cd 30cd 30cd 15cd W WP C P1•Ll-001 H Pl-Nl-06 Pl-Nl-07 30cd 30cd C �C P1•N1.09 EOL 5.1k Pl-Nl-08 30cd 15cd _ C Pl-Ll-003 P1•Ll-004 P1•Ll-005 P1•Ll-006 P1•Ll-007 Pl-Ll-009 P1•L1.011 P1•Ll-012 /� Pl-Ll-013 P1•L1.002 �--� --) �--� 1- �--� n P1•L1.008 �--� n P1•L1.010 �--� �--� n n n n n r n r n n r,llvli SeaCom FIRE & SECURITY 3014 Hoyt Ave. Everett, WA 98201 P: 425.3 1 7.8259 F: 425.317.8261 www.callseacom.com m NICET n Kory Mehl NICET FAS III #160751 IL d d Q UJ ❑ Z O Z > O w F U rn LU a E n Z N O N CV 6 co 0 r- II - hi m to o Eco z O 0 (D co o N o Cfl m (D C C > C l7 (D > U) 3 @ 0 Q 0 Q CD UWN O U o�:�0 WQ0 NNO0 Qrn_ WO _�0U MMWU LL�� ��QQ OC)0� O-LL§twin W W U) W � � YW N �o 00 �>- >Q 2U) Q� 2 U) H Q �Z 60 N� 04 SHEET REFERENCE NUMBER: 1 TOTAL SHEETS 3 mil 101111111 ■ mil