Loading...
APPROVED ENG RESUB1 BLD2023-0275+CIVIL PLANS+5.30.2023_9.06.47_AM+35742882300 F \ D/W OyT ENDS W 0 OHPT OHPTSU7= TOP S/N 05 J, V,27 P.N. 0061040400002700 w N o _ - °' -\_ _�\m \�\ _ / I I I SSMH \� - 1 RIM 280.39 o STOP x \ -�C - _ _ / I P.N. 27032500312600 - - 8" PVC E 269 89 1 8" PVC N 269.79 6' VBF \ 5' CLF VCB VCB \ \ - 5' CLF\ i / III N88°3 ' W 1316.06 C (1315.80 P) NORTH LINE NW QTR SEC. 36-2/N-3/ / / N88N88� -K630.77 GRID l - eAsrs of LAR1/VOS 657.90 P - - - �\ \ \ \ \ \ �\ 1 I 1 \ D/W o - o 22 H STREE '4. CL \ \4 G- t -� _ -I1 \\ \�� EDG'L�OF PAVEMENT \ � X \ \ CLF \ \ a n, , �OVERLA`Y �, n: _ /�, A o SS I \ \ \ ------�--- i \ O------r. r- - --- ---- - - r I vi S SS \ S \ \ � I S \ � S can i / / l o I l ADDf�ESSE5 \ \ \ \ \ \ \ / x SD / ..... / / GUTTER / J ..... \ \ \ 4 F GATE - - - - - - - - - F. \ - . ,.S/N.... _ \ ED W/TRMR ,/ / - -� F;1o1� 4' CLF 4„C P / _ / _ %P HP �P O. P „ _ & UGP j a EX CHAINLINK FENCE :�� F \ 4'�LF - - \ tip.. P ., F \ \ \ 8° P 71 (71 o cn 21 /' \ F tie \� \\ iiVsTAtL-TR€ �R,O�TION- - \ F.. F� \ \; \ \ . D P / / VEG / F-tie C. \ \ F9R EX�EES TQ REA�IAIIq- rri�: I j' 0 '� ... ... A` / �� �-`� \ \ \ \ \-SEDETAIL SID % SD- -SD D =D- SD I -FF _ - -_ ---�-_ / ... - - / RIM 5:01..... / 7 275.54 D/W � / / � - / AREA DRAIN-LG 273.84 1............ r� CB ITYPE-1 18" CONC IS 270.76 / T -4W 2.�6 �- I W SW \ \\ 269.94 Q 1 4 RIMI 275.90 /t 8" PVC W 269.76 / / 6" CONC W 7n6 � � / _ W 269.82 0 I o 8" �ONC W 274.40 24 CMP W 269.76 / 7- I �\ oN / / °tiT RI MF1 RIM 301.31 P/D 8" PVC N 294.26 8" PVC W 294.16 W/TRMR 0 �h CB TYPE STOP RIM 275.71/ SDMHRIM >0102 \ I 8" PVC E/272.96 8" VISIBLE / I I 4' F 12" VC W 272.37 Q / / .. / 36' C N 270.27 / J RAMP I o .. INSTALL SILT 0) / / I,/ I FENCE (TYP) SEE DETAIL 15 I IP Sp / �, OF / 1 " P NE 274.81 / 3.0 O / �C / � / I � / /DE IS RACK / I I .. 4 IP / RAREA DRAI IM 278.89 -LG e / \ I / C� \ M g / 6" PVC S 76+11 D �, r PRQVIDE II Lrr PR ECTION I / / 0 .... FOR CAT4H B SIN GRATES I I oSSMH 278.97 / �\ TH E P RKI LOT AND I 1 ' ' ' / I ` / / A 1 269.37 AY AS NEEDED. EXISTING C I PROPOSED LIMITS OF / / 269.\ _ C / / PLAYFIELD . 269.22 22 I I M \ � FENCING (TYP) WALKING PATH SEE / SHEET C2.00 (TYP) �/ I _ � \ J I I v`-, ,, \ \ / I SEE DETAIL 20 o WOODED SLOPE NOT INCLUDED IN SURVEY OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. Call before you Dgg.8-1-1 or 1-800-424-5555 UNDERGROUND 0 10 20 40 SERVICE (USA) JUO SCALE 1 " = 20' Sheet Index C1.00 TESC PLAN C2.00 CIVIL SITE PLAN C3.00 SITE DETAILS LEGEND PROPERTY LINE N 7933'06" E - 46.81' LIMITS OF CONSTRUCTION = LIMIT = FF FILTER FABRIC FENCING CF TEMP CONSTRUCTION FENCING STRAW WATTLE SW CG TEMP CONSTRUCTION GATE INLET PROTECTION IP VEG TREE PROTECTION OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE I \ / INSTALL STRAW 1103 II � .../ / / _\_ I \ \ \ / J I 3 0/' I WATTLE (TYP) I I I D\ \\ I ARE DR N-LG/ / / I SEE DETAIL g RIM 279.4 6" VC N/Sb76.28 W/TFM R. \ I P I / CB PE- CENTER GRATE Ry I II OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. �I RIM 78. / I 18" JON �/S 272.64 INSTALL CONSTRUCTION FENCING (TYP) CIO SEE DETAIL 20 3.0 QI I - _ 1. (........ ........ EXC CO / Q �28"s\ \I I II I SPORTS FIELD DRAINAGE SYSTEM / I I I AfI;EA JAIN-LG AND SHALLOW SWALE RIV / 28415 / UNABLE TO CONFIRM CONNECTIONS 6' PVC�NW/S 276.82 / BETWEEN STRUCTURES AND TO / I ADJACENT STORM SYSTEMS FROM EX ASPHALT I FIELD OBSERVATIONS II I � I I I PARKING LOT 1 / I / INSTALL CB PROTECTION (TYP) c� SCHO L I 20 MIT- F I SEE DETAIL r�' I I I � F � I AREA DR4N-LG 0 SW RIM 28J � f9 6 / I 6" PV)2 NW/SE 277.34 � _ j� �, l / _ CO IN , WOODED SLOPE N IN SURVEY OINCLUDED IP OHPT PT �. I \ PROTECT EX AREA DRAIN _ SCHC Q I .I.......I.. / EXC �, N I I.. I I / \ / AND ASSOCIATED N88°36'43"W 618.25 C (618.38 P) I 1 I � I I I \ �/ / / STORM PIPING TO ..I\\ / \ \ / REMAIN (TYP) FF 9 / / \ \/ , SPECIAL INSPECTIONS REQUIRED 0 , / AREA DRAIN -LAG\ FOR PERMEABLE PAV E M E N T 1 / RIM 282.28 AR A DRAIN-LG / RIM 281.4 6" PVC W/E 279.73� \ RIM, 283.57 6" PVC / E 27 .39 \ \ 6"PVC S/W 281.97 IP �' I N -A SD SD SD SD 12' CLF 1214 ' CLF IP / Q" III I PLAYGROUND c� I m Io I EQUIPMENT 11 " hROIN SE`180+24 L... I o / / \ (WOOD CHIPS) l \\ \I I EX PLAYGROUND METAL- 1 I o.\\ \\\ \ I\ \ I )\ J BENCHES r IP A, \ \\\ \\\\\ a\ B TYPE-2 _0 EEATI G AREA \ X�- / ED \ \ \ \\_ \ RIM�182 09, SAT POST O Q. / PED \\ �\ \ 1�� OQ274.10 ATCH / / W__ \ D C N�M1E9 AD �� ��� RCF�R �1 S C`6I NECTI01�1� \ _ UNA��E\�9 1D}ES1�R �21PE�IA1 �RT� �SMH o s�t FAG SD\ o T OHIT . \ �� \ \� \ G GA POST \ \ \ \ IMQ82 \ LATC X v Z71.8a \ \� IR S\2720 \ \ o / \ STRUC E I NUIt ' IANXLED� A� ST \ _ ~ \ \ SUMP h� G S€WAVIMI�E , a VV / I ° Rq�SE 4\�F \ \ \H D I I P C�Nc wq 1 �K XC � FIR TRAPE-- cn \ \ \ \ I I4 �\\\ So �v STOP GAS I I vU0 I '� / /' �\ \ \\ DAL_ 9fNSS / S I = I / / '`' / \\ m h /........ V7 ti8 IP�F' O PT- 'V7nC� N /P X 30' Cn 0 x �i i i Wy�P& %J� j OHPT \`` D III / ,- o '` \ � I \• 20'T m o i C. -\ I I I I l l ,HALT PARKING L(K I Gas\- I I I r GA \ . ,G S nn M /AREA DRAIN-SM RIM 283.04 / 4"PVC S281.81 I/ AREA DRAIN-SM BRI K RIM 283.08 4" PVC N/S 281.71 ] AREA DRAIN-SM RIM 283.06 6" PVC S 282.21 7 , 4' CLF 4' CLF X - \ 1 P CONIC RET BORDER (TYP.) I I / I PLAYGROUND o 1 EQUIPMENT V) (WOOD CHIPS) I I N J / AREA DRAIN-SM / I BORDE . BORD \ RIM 283.03 / I \ �PROTECT EX 6" PVC S 282.18 / / PLAYGROUND AREA TO / \ REMAIN PLAYGROUND POWER CABINET EQUIPMENT e 8 e ® ' (4 4' CLF I (WOOD CHIPS) 4' 1�LF 4' CLF I / �X X /r� GATE / EXC P \ \ CB TY E-1 / \ 1 R91 IRON NW 2 0.8�, SD SID SD EX ASPHALT PARKING LOT O� OLD LOCATE FAINT D H� o IIIII� �I� C Q c� -SW SW SW ' CLF I SW o DEMO THIS PIECE OF N ICHAINLINK FENCE, PROTECT EX GATE AND INCLUDING POSTS AND INCLUDING FENCE TO IP FENCING MATERIAL REMAIN CB TYPE-1 S RIM 283.89 SD-\ / 8" GONG S 282.39 COI AI EX ASPHALT I \ PLAY SURFACING \ PROPOSED CONTRACTOR \ LAYDOWN AND STAGING AREA I/ BUILDING � - _- - - - - - - - - GAS S LOCATE D I G S O PAINT � m / I _AAnn I ENDS / � \ o i I COMPLIES WITH APPLICABLE CITY STORM CODE (� 07/06/2023 REFER ALSO TO: STORM WATER MANAGEMENT REPORT PREPARED BY JACOBSON CONSUL.TING ENGINEERS AND DATED JULY 5, 2023. ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. SEE ARCHITECTURAL PLAN SHEET G0.00 FOR ADDITIONAL SITE INFORMATION (PLAYGROUND AREAS, GOAL POSTS, FIELD LAYOUT, ETC) COORDINATE WITH SCHOOL DISTRICT FOR ACCESS TO AND FROM PROJECT SITE GENERAL DEMOLITION AND TESC NOTES 1. NO SEDIMENT SHALL BE TRACKED INTO THE STREET OR ONTO PAVED SURFACES. 2. TESC INFORMATION SHOWN ON PLANS IS FOR PERMITTING PURPOSES ONLY. CONTRACTOR SHALL REVISE OR INSTALL ADDITIONAL TESC MEASURES AS CONSTRUCTIONS CONDITIONS CHANGE. 3. CONTRACTOR SHALL INSTALL TEMPORARY CONSTRUCTION FENCING AROUND JOB SITE TO PROTECT PUBLIC AND MAINTAIN PROJECT SITE. y 4. ALL DISTURBED AREAS THAT WILL NOT BE INSTALLED WITH y POUROUS ASPHALT PAVEMENT, SHALL BE COMPOST AMENDED PER 2019 STORMWATER MANAGEMENT MANUAL Y FOR WESTERN WASHINGTON BMP T5.13. -( Y SEE DETAIL 7/C3.00 ,( Y y 5. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING y TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING Y CONSTRUCTION. -( ENGINEERING DIVISION APPROVED AS NOTED 06/29/2023 ' M Reviewed by 1 City of Edmonds ; 1 1 Planning Division City Of Edmonds Building Department Work WALKING PATH/PLAYGRUND Address 22901 106THAVE W -- Owner SHERWOOD ELEM -------------------------- Approved Date Building Official Permit Number BLD2023-0275 HUTTEBALL OREM,US architr� 4010 LAKE WASHINGTON BLVD NE SUITE 320 KIRKLAND, WA 98033 425.828.8948 HOARCH.COM ARCHITECT STAMP CONSULTANT STAMP V. 06/�5/2023 it JC JACOBSON CONSULTING ENGINEERS PROJECT INFORMATION Sherwood Elementary Walking Path & Playground Improvements 22901 106th Ave W Edmonds, WA 98020 EDMONDS SCHOOL DISTRICT #15 BLD2023-0275 SCHOOL DISTRICT LOGO Edmonds School District 01.10.23 CHANGE PATH TO 6FT WIDTH �1 01.12.23 COORDINATION UPDATES �2 2.08.23 PAVING AREA REDUCTION 03.03.23 PERMIT SET 05.17.23 PERMIT COMMENTS ::::4] PERMIT SET 05.17.23 PROJECT NUMBER: 2301.2 SHEET NAME TESC PLAN RESUB May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES SHEET NUMBER C1.00 27 P.N. 00610400002700 2300 \ SSMH CO RIM 280.39STOP P.N. 27032500312600 x� 8" PVC E 269.89 / \ \� \ I I 8" PVC N 269.79 o D W VO \ 6' VBF \ \ 5' CLF 5' CLF CD o °n'r / VCB / - z I I I I SSMH _ / / / VCB RIM 301.31 / NORTH LINE NW QTR SEC. 36-2/N-3/ / \ 1 \ N88°3 ' W 1316.06 C (1315.80 P) / � , c`� _ _ P/D g PVC W 29416 8" PVC N 294.26 oyT � - / _ / _ N88°36'44"W �630.77 GRID �, � , -?- eAsrs of RiNcs - - - � �� \ � \\ \ \ \ \ � � \ � 1 I � \ � � D/W a ENDS-,--,", \ - f -� 657.90 P - \ \ \ - - + _ - - - °H STREET SW EDG`11 OF PAVEMENT O X 41 CLF \ \ '`/r 22 - - RL �^ cn X \ o a n. ir, \ \ �OVE `'d. - - - - - - - or . --- - - S S I r OS \ / ram. _ -c'�- -r--._ - /� I vi S SS S \ S -OHPT OHPT N U) N / / / / lO ADDNESSE5 \ II / / J..... I. ..... I\ \ \ \ \ \ _ SD / / GUTTER \\ \ \ \ \ o / - /. - ! - I J \ \ \ \ \ \ \ \ \ \ \ / / W/TRMR TOP M - - - - - _ j - \ I GATE _ I S/N 4 F F� 1a- \ \ 'iy S N /�iPT / ED CLF 4 C F T T T / 4'. G ... �� - /PTT- pHp pH / . n' ED W/TRMR /` / :26 , ° L .tip 4 ^ CLF �� - _ I I E - OJI- P P O P a \ . .... 6�44 EX CHAINLINK \ \ \ o p 900105 j� cn k / \ 2 cn cn: FENCE -_- F `.... 2 \\ L_>� \ O _ °fie Q vDg / / 279.28 c LSD... % SQ-. D SID278.79 SD 278 86 F.y .. .. c` 278. 6 �8\ \. \ ..... Fi F1a r /� ........... �� / 278.76 (EX) ° 275.54 D/W ✓ / RIM 174.44 E 273.84 1........ r� CB ITYPE-1 1 p 7 I \ \ \\ 269.94 Q 4 RIMI 275.90 8 R / 6" GONG W 2 \ \\ N 278.65 (EX) 269.82 11 0 8" �ONC W 274.40 / 2 �0' 283.24 / / \ 1 .. N / // 278.80 278.7o�Ex> / / \1 �> . �lc . CB TYPE-1 / 283.36 \ STOP 1 RIM 275.71/ SDMH 95 / / >0102 / I 8" PVC E/ 272.96 / RIM 276.67 8" PVC W NOT VISIBLE / / / _ 283.54 WOODED SLOPE I 4' F / / 12" PVC SW 272.37 / / 283.14 (EX) NON INCLUDED .. 36" CMP N 270.27 / J / O RAMP I o / / / - ' / / / / �'y � / 283.69 cn / / / / / / / 283.43 (EX) � 12" PVC NE 274.81 / / / // 283.59 (EX) W/DEBRIS RACK / / 283. 4 (EX) / 173.75 0' / AREA DRAI RIM 278.8 \ I / / 284.t 4 6" PVC S GAS � \\ ,�' 0 X ) r 278.97 269.37 e ' I �� I\I / C ` \ // EXISTING 269.22 \ / / I 176.790' / PLAYFIELD 269.22 I I M 280.04 \< / o \ \ / I -0 0 279.94 (EX) 1103 / / / I I � / I RIM 6" /S/276.28 / W/TFM R. J / W/CENTER GRATE R / I I C�Pt/ �P O\e \ / w \ Q _Pt......... 1 I / � I / INSTALL NEW POROUS EXC........ I I / / I T _ 1 / M ASPHALT WALKING PAH I I -... �.\ I / cn I / SEE DETAIL 19 I I i o I / 3.0 I / Q - Zak `- A -LG I SPORTSAND FIELDLLOW SWANS GE SYSTEM RI / UNABLE TO CONFIRM CONNECTIONS 6' S 276.82 / BETWEEN STRUCTURES AND TO ADJACENT OBSERVATONSRM SYSTEMS FROM FIELD / I EX ASPHALT Q \ II \ I PARKING LOT c� SCHO LI / 20 MITT \ C) 0 AREA DR4N-LG RIM 7Rn/Cq Q O / { 284.82 280.96 280.86 (EX) 0// // I �Q1 284.72 (EX) WO ODED INCLUDED 20' \ /. / / I I / 1 / / s118 / I PROTECT EX AREA DRAINS AND / IN SURVEY o / I // ASSOCIATED STORM PIPING TO / I l I , 281.77 (E)O REMAIN (TYP) / _ I - -OHPT FIPT ' PT CD I I.... I I I EXC �r� \ 1 281.88 R10 282.45 (EX) / REPLACE EX AREA DRAIN FRAME �� N88°3 618.2 8.38 P I I I \ I R10, / AND GRATE WITH NEW FRAME AND I 282.20 / NON -SOLID SLIP METHYL MET ACRYLATE I (MMA) COATING. COATING SHALL BE ° PLACED PER MANUFACTURER'S I 1No 282.30 282.55 RECOMMENDATIONS. \ V. 282.86 1 I e 1 J'c�, ° < `v AREA DRAIN-L I - - \ \ 1 L / \ RIM 282 28 AR A DRAIN-LG "- W/E 279. % 283.5 (EX) R14 283.57 / R11' NEW PLAYGROUND ,/ 6" PVC S/W 281.97 282.96 282.9s AREA PER ARCH'L, II 283.59 (6) 284.75 (EX) \ i R5' PLANS SD sD �12�LF 282.96 (EX) 283.08 �L - - - \ 12' CLF Q I ➢\TI - 2 2 INSTALL NEW POROUS ASPHALT \ I \ 1 PLAYGROUND I� g! (EX c� I m to I I I I I I I I - / x EQUI I. AEA �RAINISM I I I I I I I I I 28 s PAVEMENT TO SERVE AS PLAY AND I I I I I1�" hROIN SE1280.24 U) / hAlnr RIM 83.04 . CON RE J ACCESS TO FIELD i I/ I4" P cs1281.II1 I I I I I I .� i cn 1 1 I / SEE DETAIL 19 / I I. I I I I � MATCH EX .BORDER (TYP.) I ASPHALT GRADE /I d I I I I I I I I I I 3.0 I I\\ I I I I I AEA RAIN I SM PLAYGROUND EX PLAYGROUND \ 1 `_ - J ^ METAL gRl K I I RIM I283.OI8 : I I I I EQ� IPMENT. I I I \ \\ \\\ \ I\ ; I %\ J / BENCHES 4 PVC N/S 281.71 (WOQD CHIP$) . . I I I I I I. I I I I I I I I TO FILL IN GAP IN FENCE 3 � 20' I �° \ V A V A \ V A - - - SD �� f � ' \\\ 0 , RIM A DR IN-SM I I I I I I I I I I \ PER ARCH L PLANS AREA ' 136'-SM \ \ \\\ \� 6" PVC S.2 2.21 / BORD PROTECT EX ' \ \,� I I I I 6[MPv�3s 282:18I I I f PLAYGROUND / \ \ \ \ \ B TYPE-2 EX EATI G AREA / ED �, \ \ \ \ RIM-282109, _CAT POST o - / \ 8 C S 274.10 I (� AREA TO REMAIN / PEDDON�MIE9 ARl` D C� �1� - \ PLAYGROUND W � � POWER CABINET � EQUIPMENT _ R F �STP, C`OI NECTI0�1� o G G SD 4' CLF f UNA\�9S1�R �IPE�IAI /��RT� \ �SMH s�N F� 4' CLF EA 8 El ® / 284.19 ( 4 E �I (WOOD CHIPS) o T\ off \� \�\ IM,282 \ G GA POST X X ;� 4' 1�LF " 85.07((EX) W Z72.8aLATC Sp x /X IR S\272�o � \ STRU I N ANIdEJLED� EXC P I � 4' CL EXC 284.51(E CLF W = \ \ SUMP h•G S€WADE �� H DST \ - \ P P , aj ° Rq/S 4\ F \ \ \ \ P P NEW CHAINLINK FENCE 284.94 (EX) Fp C° 1Z ` \ PROTECT EX GATE I NC Wq \ C� \ F TO FILL IN GAP IN FENCE X� CB TY E-1 / m AND CHAINLINK \ \ \ RIM 2813.19 / I PER ARCH L PLANS FENCE TO REMAIN 606 W / CB TYPE-1 \ 2" IRON NW 2 0.8� MATCH EX S RIM 283.89 C/, / \� _ r FIRE (ANE�_ \ \ \ \ SD SD_ - - SU SD SD ASPHALT GRADE 8" GONG S 282.39 to I Gj TRIPE cn \ \ \ S� -0 Zg� / \ \ \ \ EX ASPHALT cON�- //yy I I �� / �\ \ \ 8�\ PARKING LOT I RAMP STOP GAS `06 /\D Q / 9 NSS S I I \ \ CD o EX ASPHALT ._ D / / / X P PLAY SURFACING G U) / c� OLD LOCATE FAINT D W/�1U�P &JJGC // ,/ M 1 gyp\ HC o 0 0 0 o P \ / a Q // /� / / / / / / / / SQ �O w \ o X ` / KEEP OFF m O PT OHPT / / / / C \ " " I n � \ BANK N/P I D cn ri r rl� r 1 \ O O O PORTABLE a: I I I P / / ` m \ / BUILDING \ �I I / 30' 20' Cf) Cn HALT I o /�---------- \\ A PA GAS III I I I Ir \ GAS G S rS PAINT -LOCATE n II I � I. I I I I I I, �G S 4nn �S nn M-� M nn I ENDS A o� Call before you Dgg.8-1-1 or1-800-424-5555 UNDERGROUND 0 10 20 40 SERVICE (USA) SCALE 1 " = 20' LEGEND PROPERTY LINE N 7933'06" E - 46.81' CONTOUR (INDEX) �1 CONTOUR SPOT ELEVATION �f TC 109.86 109.36 BC 109.36 GRADE BREAK - -RIDGE - - - - - - POROUS ASPHALT SEE ARCHITECTURAL PLAN SHEET G0.00 FOR ADDITIONAL SITE INFORMATION (PLAYGROUND AREAS, GOAL POSTS, FIELD LAYOUT, ETC) COORDINATE WITH SCHOOL DISTRICT FOR ACCESS TO AND FROM PROJECT SITE GENERAL GRADING AND DRAINAGE NOTES 1. CONTRACTOR SHALL POTHOLE AND VERIFY OR HIRE A PRIVATE UTILITY LOCATE COMPANY TO LOCATE ALL UTILITIES WITHIN THE JOB SITE PRIOR TO STARTING CONSTRUCTION. 2. CONTRACTOR SHALL VERIFY EXISTING GRADES AROUND PROJECT SITE PRIOR TO STARTING CONSTRUCTION AND NOTIFY CIVIL ENGINEER FOR ANY CONFLICTS WITH DESIGN GRADES. 3. PROTECT ALL EXISTING STORM DRAIN OUTFALL PIPES AND DRAINAGE STRUCTURES AS INDICATED ON PLANS. 4. PROVIDE HYDROSEED AT A MINIMUM FOR ANY GRASS AREAS THAT ARE DISTURBED DURING CONSTRUCTION. 5. EXISTING IRRIGATION LINES MAY BE LOCATED BELOW FOOTINGS OR WITHIN LIMITS OF PROPOSED WALKING PATH. CONTRACTOR SHALL CUT AND CAP IF IRRIGATION LINES DISCOVERED. COORDINATE WITH OWNER PRIOR TO PERFORMING THIS WORK. 6. THE NATIVE SOIL SUBRADE AT THE BASE OF PAVING LAYER SHALL BE EXPOSED BY EXCAVATING AS NEEDED, THEN LIGHTLY SCARIFIED PRIOR TO PLACEMENT OF THE FIRST LAYER OF THE PAVING SECTION. 7. COMPACTION OF THE PAVING SECTION LAYERS SHALL USE LIGHT -DUTY .� EQUIPMENT SUCH AS A VIBRATORY SLED OR SMALL DRUM ROLLER. COMPACTIVE EFFORT SHOULD BE ADEQUATE TO MEET COMPACTION STANDARDS BELOW PAVING, BUT OVER -COMPACTION SHALL BE AVOIDED. 0=01100040 Earthwork Ouantities EXCAVATION 330 CY FILL 12 CY NET EXCAV/FILL 318 CY TOTAL EARTHWOR 342 CY NOTE: THE QUANTITIES SHOWN ARE PRELIMINARY ESTIMATES ONLY AND INTENDED FOR MUNICIPAL PERMITTING AND REVIEW FEES. THE CONTRACTOR SHALL IGNORE THESE QUANTITIES, THEY ARE EXCLUDED FROM THE BID DOCUMENT INFORMATION. THESE VOLUMES SHALL NOT BE USED BY THE CONTRACTOR AS A BASIS FOR ANY CONTRACTUAL INFORMATION. THE CONTRACTOR SHALL PREPARE THEIR OWN EARTHWORK QUANTITIES BASED ON THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS, AND SPECIFICATIONS. NEW & REPLACED IMPERVIOUS LEGEND QUANTITY S P 9,784 TOTAL NEW & REPLACED IMPERVIOUS: 9,784 SF HUTTEBALL IP, *OOEMOS 10 wChIltectw! 4010 LAKE WASHINGTON BLVD NE SUITE 320 KIRKLAND, WA 98033 425.828.8948 HOARCH.COM ARCHITECT STAMP CONSULTANT STAMP -W Rt W 05/15/2023 JC JACOBSON CONSULTING ENGINEERS PROJECT INFORMATION Sherwood Elementary Walking Path & Playground Improvements 22901 106th Ave W Edmonds, WA 98020 EDMONDS SCHOOL DISTRICT #15 BLD2023-0275 SCHOOL DISTRICT LOGO �*1 Edmonds Imo: School District 01.10.23 CHANGE PATH TO 6FT WIDTH �1 01.12.23 COORDINATION UPDATES �2 2.08.23 PAVING AREA REDUCTION 03.03.23 PERMIT SET 05.17.23 PERMIT COMMENTS �4] PERMIT SET 05.17.23 PROJECT NUMBER: 2301.2 SHEET NAME CIVIL SITE PLAN RESUB May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES SHEET NUMBER C2m00 NTS 1 Not -(: Used NTS Not --(: 6 Used NTS 1 1 Not Used Figure V-11.1: Planting Bed Cross -Section Mulch AK 811 Loose soil with visible dark organic matter 411 Loose or fractured subsoil Reprinted from Guidelines and Resources For Implementing Soil Quality and Depth BMP T5.13 in WDOE Stotmwater Management Manual for Western Washington, 2010, Vashington Organic Recycling Council NOT TO SCALE Planting Bed Cross -Section Revised June 2016 DEPARTMENT OF ECOLOGYPlease see http.yAvww.ecy wa.gov/copyright.html for copyright notice including permissions, State of Washington limitation of liability, and disclaimer. 2019 Stormwater Management Manual for Western Washington Volume V - Chapter 11 - Page 930 NTS _(:7 Compost Amended Soil BMP T5.13 NTS 1 Not Used CONTOUR LINE (TYP) ANGLE TERMINAL END UPHILL 24" TO 48" TO PREVENT FLOW AROUND WATTLE (TYP) PLAN VIEW r AREA AVAILABLE FOR SEDIMENT TRAPPING (n'P) WATTLE TRENCH, SEE NOTE 2 2" MIN 5" MAX z 2"x2"x24" UN -TREATED iv WOODEN STAKE (TYP) SEE WATTLE TABLE (TYP) WATTLE (TYP) SEE DETAIL SECTION A -A WATTLE INSTALLATION ON SLOPES 2"x2"x24" UN -TREATED WOODEN STAKE (TYP) 3" MIN 4" MAX 8" DIAMETER MIN WATTLE DETAIL 8" DIAMETER SPACING WATTLE TABLE SLOPE MAXIMUM SPACING 1H:1V 10'-0" 2H:1V 20'-0" 3H:1V 30'-0" 4H:1V 40'-0" >4H:1V ONE RUN ONLY NOTES: 1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION. 2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS. INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10). 3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT UNDERCUTTING. 4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. Sl 18�� REVISION DATE CITY OF EDMONDS JANUARY 2018 WATTLE INSTALLATION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH E R- 9 0 3 NTS n Straw Wattle a BARRICADE FENCING (ORANGE QX>S�S12 S� CONSTRUCTION FENCE) MIN 4' �� HEIGHT SURROUND TREE OR 2' POST BURIAL DEPTH GROUP OF TREES AT DRIP LINE OR AS SHOWN ON PLANS NOTES: 1. A MINIMUM 4 FOOT HIGH TEMPORARY FENCE MUST BE PLACED AT THE DRIP LINE OF TREES PRIOR TO THE COMMENCEMENT OF CLEARING OR EARTHWORK. NOTIFY THE CLEARING AND GRADING INSPECTOR TO GET BOTH THE INSPECTION AND WRITTEN APPROVAL OF FLAGGED TREES AND TEMPORARY PROTECTION FENCING AROUND TREES TO BE SAVED PER THE APPROVED CLEARING AND GRADING PLAN. 2. NO STOCKPILING OF MATERIAL AND NO VEHICULAR TRAFFIC ARE ALLOWED WITHIN THE LIMITS OF THE TEMPORARY FENCING. FILLING, EXCAVATION, AND CLEARING MUST BE ACCOMPLISHED BY HAND METHODS ONLY. 3. ROOTS OF TREES TO BE SAVED WHICH ARE DAMAGED DURING CONSTRUCTION MUST BE TREATED IN THE FOLLOWING WAY: FOR DAMAGED ROOTS OVER 1" IN DIAMETER, MAKE A CLEAN, STRAIGHT CUT TO REMOVE THE DAMAGED PORTION OF THE ROOT. ALL EXPOSED ROOTS WILL BE TEMPORARILY COVERED WITH DAMP BURLAP OR WOOD SHAVINGS TO PREVENT DRYING AND COVERED WITH EARTH AS SOON AS POSSIBLE. 4. SEE TREE PROTECTION AND TESC PLANS FOR LOCATION OF EXISTING TREES TO RECEIVE TEMPORARY FENCING. 5. SEE SPECIFICATIONS FOR PRUNING, WATERING, AND OTHER MAINTENANCE REQUIREMENTS NTS 13 Tree Protection CITY OF EDMONDS PUBLIC WORKS DEPARTMENT 4" (MIN) PAVEMENT BASE COURSE, SEE NOTE 2 6" PATE: 2', MIN (MIN) OR CSCC: 3" (MIN) OR PER MANUFACTURER RECOMMENDATION CATCH BASIN GRATE FILTER SOCK WITH OVER FLOW HOLES (n'P) CATCH BASIN NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY SEDIMENT TRAP FOR CATCH BASINS APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD D ETAI L ER-902 NTS Inlet Protection POROUS HMA/WMA, SEE NOTE 1 PERMEABLE ASPHALT TREATED BASE COURSE OR CRUSHED SURFACING CHOKER COURSE, SEE NOTE 3 PERMEABLE BALLAST, SEE NOTE 4 RU REATMENT LAY (IF :REQUIRED DMONDS 1' (MIN) ABOVE SEASONAL HIGH _F ST R CODE), S 5 GROUNDWATER TABLE OR HYDRAULICALLY RESTRICTIVE LAYER SUBGRADE, SEE NOTE 6 GENERAL NOTES: 1. REFER TO THE 2022 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK (CHECKLIST 11) AND INFEASIBILITY REQUIREMENTS. 2. THE MINIMUM THICKNESS SHOWN ABOVE MAY NOT BE SUFFICIENT FOR ALL APPLICATIONS. A PROJECT SPECIFIC PAVEMENT DESIGN SHALL BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN CIVIL ENGINEERING TO: 2.1. SUPPORT THE ANTICIPATED LOADING (E.G. PAVEMENT DESIGN LIFE, INITIAL AND TERMINAL SERVICEABILITY, RELIABILITY, ETC.) AND 2.2. TO SATISFY THE HYDROLOGIC REQUIREMENTS OF THE CITY OF EDMONDS STORMWATER CODE (I.E.. CODE MAY WARRANT A THICKER PAVEMENT SECTION THAN THE MINIMUM STRUCTURAL SECTION REQUIRED). 3. FOR SUBGRADE SLOPES 3% OR GREATER, SUBSURFACE CHECK DAMS OR OTHER METHODS TO PROMOTE SUBSURFACE PONDING ARE REQUIRED (SEE SD-627). 4. IGEOTEXTILE SHALL NOT BE USED IN PAVEMENT SECTION UNLESS REQUIRED BY GEOTECHNICAL ENGINEER. IF REQUIRED, GEOTEXTILE SHALL CONFORM TO WSDOT 9.33.2(1) GEOTEXTILE FOR SEPARATION, WOVEN TYPE. 5. REFER TO WSDOT LOCAL AGENCY GSPs DIVISIONS 2-9 FOR APWA GSPs. NOTES: 1. POROUS HMA SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-04. 2. SURFACE SLOPE SHALL BE BETWEEN 0.5% AND 6%. 3. PAVEMENT BASE SHALL BE INSTALLED PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION. 4. PERMEABLE ASPHALT TREATED BASE (PATE) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-SA2. CRUSHED SURFACING CHOKER COURSE (CSCC) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT2. 5. PERMEABLE BALLAST SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT1. 6. RUNOFF TREATMENT LAYER SHALL MEET THE REQUIREMENTS OF 2022 CITY OF EDMONDS STORMWATER ADDENDUM. 7. PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. REVISION DATE CITY OF EDMONDS TYPICAL POROUS APRIL 2023 ASPHALT PAVEMENT PUBLIC WORKS STANDARD DEPARTMENT DETAIL �S t . I B') APPROVED BY: R. ENGLISH S D- 621 WIRE FENCE 10' TO STEEL POST _ CLIP FENCE TO WIRE - STEEL FENCE POST 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL 8" TENSAR GS-1 SAFETY FENCE OR EQUAL GALVANIZED WIRE OR OTHER APPROVED MATERIAL NTS 5 Clearing Limits Fencing FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS -\ I I I TMESH FENCE TO SUPPORT FILTER ABRIC BURY BOTTOM OF FILTER N MATERIAL 8" TO 12" NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS ACTIVITY. BEFORE OTHER WORK CAN BEGIN REVISION DATE __tNq1_ 1 FILTER FABRIC FENCE JANUARY 2018 4 4 CITY OF EDMONDS FILTRATION SYSTEMS PUBLIC WORKS STANDARD DEPARTMENT DETAIL f. 18 9 0 APPROVED BY: R. ENGLISH E R- 9 0 0 NTS 15 Silt Fence 5/8" WIRE ROPE PROVIDE SECURE END ATTACHMENT AT CORNER AND GATE POSTS AND PROVIDE RUNNING ATTACHMENT AT LINE POSTS AND NEAR CENTER OF EACH FENCE PANEL TRUSS ROD 3/8" DIA W/ TENSION DEVICE rTn rTnl Irn 1.666 INCH O.D. STD WGT GALVANIZED CORNER POST I LIVJIVIV VVII\L CONCRETE BLOCK HUTTEBALL +OOEMOS architi>r� 4010 LAKE WASHINGTON BLVD NE SUITE 320 KIRKLAND, WA 98033 425.828.8948 HOARCH.COM ARCHITECT STAMP CONSULTANT STAMP 06/5/2023 JC JACOBSON CONSULTING ENGINEERS PROJECT INFORMATION Sherwood Elementary Walking Path & Playground Improvements 22901 106th Ave W Edmonds, WA 98020 EDMONDS SCHOOL DISTRICT #15 BLD2023-0275 SCHOOL DISTRICT LOGO Edmonds School District 01.10.23 CHANGE PATH TO 6FT WIDTH �1 01.12.23 COORDINATION UPDATES �2 2.08.23 PAVING AREA REDUCTION 03.03.23 PERMIT SET 05.17.23 PERMIT COMMENTS PERMIT SET 05.17.23 PROJECT NUMBER: 2301.2 SHEET NAME 4 7SU TAILS [DEVELOPMENT SERVICES NTS 1 6 Not Used NTS 1 Not Used NTS 1 A Not Used a NTS 1 Porous Asphalt Pavement NTS � 0 Construction Fence SHEET NUMBER C3.00