Loading...
REVIEWED BLD2023-0705+Interior_Lighting_Summary+6.7.2023_9.10.01_AM+35932262018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Old Mill Town - Suite 200 Demising - 2018 WSEC For Building Department Use: I Date' Jun 07, 2023 REVIEWED BY RECEIVED CITY OF EDMONDS Jun 072023 - OF EDMORos OEVE-LOPMENTEM SERVICES oEPnarMENT Project Address 201 5th Ave South Suite 200 Edmonds, WA 98020 Applicant Name Chelsea Merkel Applicant Phone 425-827-2100 Applicant Email cmerkel@freiheitarch.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Other Building Cond. Floor Area 7,210 General Project Types Alteration New Building or Addition Lighting S g gco a P Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 7,210 Floors Above Grade 2 Compliance Method Compliance Method 1 -General Lighting Project Description Relocating one linear fixture and revising switching as needed. Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Alteration Interior Lighting less than 50% replaced No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Proje Old Mill Town - Suite 200 Demising - 2018 WSEC Date Jun 07, Lighting Power Calculation ALTERATION - IrNTERIOR LIGHTING (less than 50% replaced) Compliance Verification I COMPLIES Interior Lighting Power Allowance Space Type Existing Lighting Wattage Prior to Alteration Total Watts Allowed Proposed Lighting Total WattsBy Building Area Compliance Status Existing Lighting 1 1,756 1,756 Proposed Lighting Power Density - Spaces with less than 50% fixtures replaced Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer 2X4 LED RECESSED FIXTURE 5 32 160 Recessed downlight DOWNLIGHT 13 12 156 Suspendedl Linear suspended fixture 32 45 1,440 Proposed Total LPD 1756 Project Title Old Mill Town - Suite 200 Demising - 2018 WSEC Date Jun 07, 2023 Proposed Fixtures Details ALTERATION - LNTERIOR LIGHTING (less than 50% replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer 2X4 LED RECESSED FIXTURE A7.01 LED Existing -to -Remain Fixture Description: Recessed downlight DOWNLIGHT A7.01 LED Existing -to -Remain Fixture Description: Suspended Linear suspended fixture A7.01 LED Existing -to -Remain Fixture Description: 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Project: Old Mill Town - Suite 200 Demising - 2018 WSEC 201 5th Ave South Suite 200 Edmonds, WA 98020 Date: 2023-06-07 Applies Code Section Component Compliance Information Required In Permit Location in Building Department Documentation Documents Notes LIGHTING SCOPE C103.1 Construction For a shell & core or tenant space (first build - documents - General out) project, indicate if there is no lighting scope included in the project. YES C103.1 Construction For an alteration project, indicate if there is A7.10 documents - General no lighting scope included in the project. LIGHTING CONTROLS YES C405.2 Lighting controls, For all lighting fixtures, indicate lighting A7.10 general control method on plans for spaces and lighting zone(s) served, or exception taken C405.2, Luminaire level Indicate on plans all fixtures provided with Option 2 lighting controls LLLC in lieu of C405.2 lighting controls; (LLLC) provide description of control capabilities and performance parameters C405.2.5, Lighting in dwelling Indicate method of automatic control of all Item 3 units (dormitory, installed luminaires in dwelling units in C405.2.1.1 hotel and all other buildings other than multifamily (occupancy C405.2.3.1 than multifamily) or light reduction controls) C405.2.5, Lighting in sleeping Indicate method of automatic off control of Item 2 units all installed luminaires in sleeping units (vacancy or key card control); also refer to Receptacles YES C405.2.3 Manual controls Indicate on plans the method of manual A7.10 C405.2.3.1 lighting control, location of manual control C405.2.5 device and the area or specific application it serves NO C405.2.3.1 Manual interior light Indicate on plans which method of manual C405.2.1.1 reduction controls 50% lighting load reduction is provided, or C405.2.4 indicate applicable exception YES C405.2.1 Method of automatic Indicate on plans the method of automatic A7.10 C405.2.2.1 shut-off control shut-off control during unoccupied periods C405.2.1, (occupancy sensor, time switch or digital Exception 3 timer switch) for all lighting zones YES C405.2.1 Occupant sensor Indicate on plans all luminaires that are A7.10 controls controlled by occupant sensor controls; indicate controls are configured to turn luminaires 100% off when the space is unoccupied NO C405.2.1 Occupant sensor Indicate if occupant sensor controls are C405.2.1.1 controls configured to be manual on or automatic on to not more than 50% power; indicate spaces eligible for exception that allows automatic on to 100% power Page 1/10 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NO C405.2.1.2 Occupant sensor Indicate each aisleway and corridor within a controls - warehouses warehouse space are designated as separate spaces zones that are independently controlled NO Indicate occupant sensors are configured to automatically reduce lighting power by 50% when the zone is unoccupied and 100% off after the zone is unoccupied for over 20 minutes; indicate controls are configured to automatically restore lighting to full power when the zone or space is occupied NO C405.2.1.3 Occupant sensor For open plan office areas larger than 300 sf, controls - open plan indicate general lighting is provided with office areas vacancy controls that reduce lighting power by not less than 80% and are configured to turn luminaires 100% off when the space is unoccupied; indicate that no individual control zone area exceeds 600 sf C405.2.1.4 Occupant sensor Indicate parking garage general lighting is controls - parking provided with vacancy controls that reduce garages lighting power by not less than 30% and are configured to turn luminaires 100% off when no vehicles or pedestrians are present, unless eligible for an exception; indicate that no individual control zone area exceeds 3,600 sf NO C405.2.1.5 Occupant sensor Indicate stairway lighting is provided with controls - enclosed vacancy controls that reduce lighting power by fire -rated stairwells not less than 50% when the stairway in unoccupied NO C405.2.2.1 Automatic time Indicate spaces on plans where time switch switch controls controls turn luminaires 100% off during unoccupied hours NO Indicate spaces on plans where time switch controls are configured to turn on lighting to full power versus 50% power NO Indicate locations of override switches on plans and the lighting zone(s) served; indicate that the area(s) served by each override switch does not exceeds 5,000 sf NO C405.2.1, Digital timer switch Indicate digital timer switch control includes: Exception 3 manual on/off, time delay, audible and visual indication of impending time-out NO C405.2.4.2 Daylight zones - Indicate primary and secondary sidelit C405.2.4.3 Sidelit and toplit daylight zone floor areas on plans NO Indicate toplit daylight zone floor areas on plans NO For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone floor area) where daylight responsive controls are not required, provide fenestration area to daylight zone floor area calculation(s) Page 2110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NO C405.2.4 Daylight responsive Indicate on plans lighting zone(s) served by controls daylight responsive controls; indicate that the area served by each control device does not exceeds 2,500 sf NO Identify sidelit and toplit daylight zones that are not provided with daylight sensing controls and the exception(s) that apply NO C405.2.4.1.1 Daylight responsive Indicate on plans the lighting load reduction controls method (continuous dimming, or stepped dimming that provides at least two even steps between 0%-100%0 of rated power) NO C405.2.4.1 Daylight responsive Indicate that daylight sensing controls are controls configured to completely shut off all controlled lights in the lighting zone NO C405.2.5 Additional controls - Identify spaces and lighting fixtures on plans Specific application that require specific application lighting lighting controls controls per this section NO C405.2.5, Display and accent Indicate on plans that manual controls are Item 1 lighting provided that control display, accent lighting and display case lighting independently from both general area lighting and other lighting applications within the same space NO Indicate manual and automatic (occupant sensor or time switch) lighting control methods C405.2.5, Hotel/motel guest Indicate method of automatic control - Item 3 rooms vacancy or captive key control of all installed luminaires and switched receptacles in guest room NO C405.2.5, Supplemental task Indicate method and location of manual and Item 1 lighting automatic shut-off control (occupant sensor or time switch) for supplemental task lighting, including under -shelf or under -cabinet lighting NO C405.2.5, Lighting equipment Indicate on plans that lighting equipment for Item 1 for sale or sale or demonstration are controlled demonstration independently from both general area lighting and other lighting applications within the same space NO Indicate manual and automatic (occupant sensor or time switch) lighting control methods NO C405.2.5, Lighting for non- Identify all eligible non -visual lighting Item 4 visual applications applications on plans; indicate that the area served by each control device does not exceeds 4,000 sf NO Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space Page 3110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NO Indicate method of manual lighting control and applicable automatic lighting control YES C405.2.5, Means of egress Identify on plans egress fixtures that function A7.10 Item 5 lighting as both normal and emergency means of egress illumination YES Provide calculation of lighting power density A7.10 of total egress lighting NO If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods NO Indicate method of automatic shut-off control NO C405.4.1 Lighting control of Indicate that exempt interior lighting C405.4.2 exempt interior equipment and lighting located within spaces lighting that are eligible for a lighting power exemption are controlled independently from non-exempt and general area lighting C405.2.6 Exterior lighting For decorative exterior lighting, indicate on controls plans automatic daylight shut-off controls, or exception taken For exterior lighting that is not decorative, indicate on plans automatic daylight or time - switch shut-off controls and setback controls; or indicate exception taken For lighting requiring setback controls, include control sequence that reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor For building facade and landscape lighting, indicate control sequence for shut-off control is based on dawn -to -dusk and business opening/closing schedule; indicate whether automatic or time switch controls will be provided for this function C405.5.2 Lighting control of Indicate that exempt exterior lighting and exempt exterior lighting located within exterior areas/surfaces lighting that eligible for a lighting power exemption are controlled independently from non- exempt exterior lighting C405.5.4 Exterior gas -fired Indicate ignition system is a method other lighting appliances then continuously burning pilot light NO C405.2.7 Area controls - Indicate location(s) of master control Master control switch(es) intended to control multiple switches and circuit independent switches; circuit breaker may not power limit be used as a master control switch YES Verify that no 20 amp circuit controlled by a A7.10 single switch or automatic control is loaded beyond 80% ADDITIONAL EFFICIENCY CREDIT - ENHANCED INTERIOR LIGHTING CONTROLS Page 4110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C406.4 Enhanced digital To comply with additional efficiency credit, lighting controls indicate on plans that interior lighting fixtures are configured with all of the following control functions, as applicable: 1) Each fixture is individually addressed, or exception taken; 2) Fixtures are configured for continuous dimming; 3) No more than eight fixtures are controlled by a single daylight sensor; 4) In enclosed and open office areas, illumination levels of overhead general area lighting is configured to be individually adjusted by occupants Include calculations that demonstrate the total lighting power of all interior lighting fixtures configured with enhanced lighting controls is no less than 90% of the total interior lighting power for the area the enhanced lighting controls credit is being applied to INTERIOR LIGHTING POWER & EFFICACY YES C405.4.1 Total connected Include all luminaires in interior lighting A7.10 C405.4.2 interior lighting fixture schedule; indicate fixture types, lamps, power ballasts, and manufacturer's watts per fixture for the installed lamp YES Identify spaces eligible for lighting power A7.10 exemption on plans and in WSEC interior lighting compliance reports; indicate the exception applied NO Identify lighting equipment eligible for lighting power exemption in fixture schedule and in WSEC interior lighting compliance reports; indicate the exception applied C405.1 Lighting in dwelling For all installed luminaires, include lamp type C405.1.1 units (multifamily) and number of lamps in lighting fixture schedule; for lamps that are not LED, T-8 or small diameter fluorescent, indicate efficacy of other lamp types is 65 lumens per watt or greater For all installed luminaires, indicate in lighting fixture schedule whether complying via lighting power density or by qualifying lamp type; if by lamp type, include number of lamps For all installed luminaires, indicate in lighting fixture schedule whether complying via lighting power density or by qualifying lamp type; if by lamp type, include number of lamps INTERIOR LIGHTING POWER CALCULATION - INDICATE COMPLIANCE PATH TAKEN NO C405.4.2.1 Building Area Demonstrate that total proposed wattage per Method building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans; provide WSEC exterior lighting compliance reports Page 5110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C405.4.2.2 Space -By -Space Demonstrate that total proposed wattage does A7.10 Method not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas and areas with display, highlight and decorative lighting; provide WSEC exterior lighting compliance reports ADDITIONAL EFFICIENCY CREDITS - REDUCED INTERIOR LIGHTING POWER DENSITY NO C406.3.1 Reduced interior To comply with additional efficiency credit, C406.3.2 lighting power demonstrate that total connected interior density lighting wattage is 10% or 20% less than the total maximum allowed lighting wattage for the area the reduced lighting power credit is being applied to; indicate whether lighting power allowance is based on the building area method or space -by -space method; provide WSEC exterior lighting compliance reports C406.3 Reduced interior For project with dwelling units, to comply lighting power with additional efficiency credit indicate in density - dwelling lighting fixture schedule that lamps within unit lamp efficacy installed interior luminaires have an efficacy rating of at least 65 lumens per watt; include number of lamps and provide calculations that demonstrate at least 95% of lamps have this efficacy rating EXTERIOR LIGHTING POWER & EFFICACY C405.5.2 Total connected Include all luminaires in exterior lighting exterior lighting fixture schedule; indicate fixture types, lamps, power ballasts, and manufacturer's watts per fixture for the installed lamp Identify exterior applications eligible for lighting power exemption on plans and in WSEC exterior lighting compliance reports; indicate exception applied C405.5.3(1) Exterior lighting zone Indicate building exterior lighting zone as specified by the AHJ C405.5.1 Exterior building For building grounds fixtures rated at greater grounds lighting than 50 watts, indicate rated lamp efficacy (in lumens per watt) in fixture schedule EXTERIOR LIGHTING POWER CALCULATION C405.5.3 Tradable allowances Demonstrate that total proposed tradable surface wattage does not exceed maximum allowed tradable surface wattage (including base site allowance); identify locations of tradable surfaces on plans; provide WSEC exterior lighting compliance reports Page 6110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Demonstrate that proposed wattage per non - tradable surface type does not exceed maximum allowed wattage per non -tradable surface type (including base site allowance remaining after tradable allowance calculation); identify locations of non -tradable surfaces on plans; provide WSEC exterior lighting compliance reports LIGHTING ALTERATIONS NO C503.6.1 Interior and parking Where _ 50% of existing luminaires in an garage lighting interior space or parking garage are replaced; fixture alterations indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed lighting wattage does not exceed maximum allowed per compliance path NO Where < 50% of existing luminaires in an interior space or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where _ 50% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in WSEC exterior lighting compliance reports; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in WSEC interior exterior compliance reports; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration C503.6.2 Interior lighting Where new wiring is installed to serve new wiring and circuiting interior luminaires and /or luminaires are alterations relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5) Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to a new circuit; indicate automatic lighting controls are provided (C405.2.6) Page 7/10 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C503.6.3 Lighting panel Where a new interior and/or exterior lighting alterations panel is installed or an existing panel is moved (all new raceway and conductor wiring), indicate all applicable lighting controls requirements apply C503.6.4 Newly -created rooms Where interior space(s) is reconfigured (permanently installed walls or ceiling -height partitions) to create new enclosed spaces, indicate all applicable lighting controls requirements apply NO C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage NO C505.1 Change of interior Identify spaces on plans where the building space use area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) NO Indicate compliance method (building area or space -by -space); include all new and existing - to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES C405.10 Controlled Identify all controlled and uncontrolled receptacles receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc Provide schedule that lists the number of controlled and uncontrolled receptacles in each space where controlled receptacles are required - classrooms, private offices, open office areas, conference rooms, copy rooms, break rooms and modular partitions/workstations Indicate on plans the method of automatic control for each controlled receptacle zone (occupant sensor or programmable time -of - day control); indicate that each zone served by a single controller does not exceed 5,000 sf C405.2.5, Switched receptacles Indicate method of automatic off control of Item 2 in sleeping units all switched receptacles in sleeping units (vacancy or key card control) C503.6.6 Electrical receptacle Where new receptacles are added or replaced alerations within an alteration project that is 5,000 sf or larger, indicate receptacles are provided with automatic controls per C405.10, or exception taken MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION Page 8110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C405.6 Electrical Include electrical transformer schedule on transformers electrical plans; indicate transformer type, size, efficiency, or exception taken NO C405.11 Feeders and branch Provide documentation that demonstrates circuits maximum voltage drop across feeders and branch circuits does not exceed 5% C405.7 Dwelling unit Indicate on electrical plans that each dwelling electrical energy unit in Group R-2 has a separate electrical consumption energy meter C405.8 Electric motor Include all motors, including fractional hp efficiency motors, in electric motor schedule on electrical plans; indicate motor type, horsepower, rpm, rated efficiency, or exception applied C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculations that demonstrate average efficacy is not less than 35 lumens per watt For elevators that do not have an integral air conditioning system, indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more C405.9.2 Escalators and Indicate escalators comply with ASME moving walks At7.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (CX) C408.4 Scope of electrical Indicate that all electrical systems power and lighting (receptacles, transformers, motors, vertical systems and horizontal transportation) for which the commissioning WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned Where total building lighting load is > 20 kW, or where total lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception C405.13 Commissioning Indicate Cx requirements in plans and C408.1.1 requirements in specifications for all applicable electrical and C408.1.2 construction lighting control systems per C408 C408.1.4.2 documents C 103.6.3 Page 9110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C408.1.2 Commissioning Include general summary of Cx plan per C408.1.2.1 requirements in C408.1.2 including: 1) Narrative description C408.1.4 construction of activities; 2) Responsibilities of the Cx C103.6.3 documents team; 3) Schedule of activities including verification of project close out documentation per C103.6; 4) Conflict of interest plan (if required) C408.1.2 Commissioning Include in general summary that a Cx project C408.1.4 requirements in report and Compliance Checklist (Figure C103.6.3 construction C408.1.4.1) shall be completed by the documents Certified Cx Professional and provided to the owner prior to the final electrical inspection NO C408.4.1 Functional Identify in plans and specifications the performance testing intended operation of all equipment and criteria controls during all modes of operation, including interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION NO C103.6.3 Project close out Indicate in plans that project close out documentation documentation is required including WSEC requirements lighting compliance reports that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities If "no" is selected for any question, provide explanation. Page 10/10