SCOPE OF REPAIR SUMMARY
ABBREVIATIONS
GENERAL NOTES
THE FOLLOWING IS A SUMMARY OF THE PROPOSED REPAIR SCOPE FOR THIS PROJECT. REFER TO SECTION
AL.
ALUMINUM
1.
IN CONJUNCTION
READ DRAWINGS IN CONJUNCTION WITH PROJECT
READ DMANUARAWINGS
011000 SUMMARY AND SECTION 011013 SCOPE OF REPAIR FOR A COMPLETE NARRATIVE OF THE WORK
APPROX.
APPROXIMATE
FI
IDENTIFIED IN THESE DOCUMENTS.
ARCH.
ARCHITECTURAL
2.
DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON SITE.
BLDG.
BUILDING
3.
DRAWINGS HAVE BEEN PRODUCED FROM AVAILABLE
THE PRIMARY REPAIR ELEMENTS OUTLINED WITHIN THE SCOPE OF REPAIR INCLUDE:
BOT.
BOTTOM
RECORD DOCUMENTS AND LIMITED FIELD OBSERVATION.
A. COMPLETELY REPAIR/REPLACE THE ROOF SYSTEM GENERALLY MATCHING EXISTING. REPLACE ROOF
CO L.
COLUMN
CO U
CONTRACTOR TO BRING DISCREPANCIES BETWEEN CERTA
MEMBRANE, STANDING -SEAM METAL ROOF, FLASHING, GUTTERS AND DOWNSPOUTS.
C.M.U.
CONCRETE MASONRY UNIT
DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE
B. REPLACEMENT OF VARIOUS WALL CLADDING ASSEMBLIES WITH NEW WATER -MANAGED CLADDING SYSTEM
CONC.
CONCRETE
IMMEDIATE ATTENTION OF THE CONSULTANT AND REQUEST
USING DRAINED STUCCO.
CENT.
CONTINUOUS
A REVIEW WHEN DISCREPANCIES ARE DISCOVERED.
C. REPAIR OF HIDDEN DAMAGES TO THE BUILDING STRUCTURES AT VERTICAL WALLS AND HORIZONTAL
CONSTR.
CONSTRUCTION
4.
EXECUTION OF THE CONTRACT BY THE CONTRACTOR IS A
STRUCTURES, AND OTHER POTENTIALLY IMPACTED BUILDING MATERIALS AND FINISHES WHERE AFFECTED
C/W
COMPLETE WITH
REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE
BY THE WORK.
DIA.
DIAMETER
SITE, BECOME GENERALLY FAMILIAR WITH THE LOCAL
D. REMOVAL AND REPLACEMENT OF SHEET METAL FLASHING ADJACENT TO WATERPROOF MEMBRANES.
DIM.
DIMENSION
CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED
DWG.
DRAWING
AND CORRELATED PERSONAL OBSERVATIONS WITH
SPECIFIC ITEMS RELATED TO THE BUILDING ENCLOSURE NOT BEING ADDRESSED INCLUDE THE FOLLOWING:
D.S.
DOWNSPOUT
REQUIREMENTS OF THE CONTRACT DOCUMENTS.
• IMPROVEMENTS TO CONTROL AIR LEAKAGE INTO THE ATTIC SPACES BELOW ROOFS.
EA.
EACH
5.
CONTRACT DRAWINGS ARE COMPLIMENTARY, AND WHAT IS
• THIS SCOPE DOES NOT CURRENTLY ADDRESS ANY FOUNDATION, BELOW GRADE OR LEVEL 1
EL.
ELEVATION
REQUIRED BY ANY ONE SHALL BE BINDING AS IF REQUIRED
WATERPROOFING SYSTEMS SITE DRAINAGE ISSUES INTERIOR MECHANICAL SYSTEMS OR OTHER
ELEC.
ELECTRICAL
BY ALL. BEFORE STARTING EACH PORTION OF THE WORK,
BUILDING SYSTEMS NOT DIRECTLY IMPACTED BY THE PROPOSED REPAIRS TO THESE SPECIFIC BUILDING
E.I.F.S.
EXTERIOR INSULATION & FINISH
CAREFULLY STUDY AND COMPARE THE VARIOUS DRAWINGS
ENVELOPE ASSEMBLIES. ADDITIONALLY, THIS SCOPE WILL NOT RESOLVE ONGOING AIR -LEAKAGE ISSUES
SYSTEM
AND OTHER CONTRACT DOCUMENTS RELATIVE TO THAT
EXCEPT WHERE ADDRESSED THROUGH THE SCOPE OF REPAIR.
EQ.
EQUAL
PORTION OF THE WORK AS WELL AS INFORMATION
• IMPROVENTS TO SWING DOORS TO FACILITATE THE INTEGRATION OF INTERFACING WATERPROOFING
EQUIP.
EQUIPMENT
FURNISHED BY OWNER. TAKE FIELD MEASUREMENTS OF ANY
ASSEMBLIES AND TO IMPROVE AIR -TIGHTNESS AND FLASHING OF THOSE ELEMENTS.
EXIST.
EXISTING
EXISTING CONDITIONS RELATED TO THAT PORTION OF THE
EXT.
EXTERIOR
WORK AND OBSERVE CONDITIONS AT THE SITE AFFECTING
AHJ REVIEW OF REPLACED SHEATHING/FRAMING
F.C.
F.D.
FIBER CEMENT
FLOOR DRAIN
IT. THESE OBLIGATIONS ARE FOR THE PURPOSE OF
FACILITATING CONSTRUCTION BY THE CONTRACTOR AND
FIN.
FINISH
NOT FOR THE PURPOSE OF DISCOVERING ERRORS,
• REPLACED SHEATHING IS TO BE NAILED PER THE FRAMING AND SHEATHING NOTES IN THESE DOCUMENTS.
F.R.T.W.
FIRE -RETARDANT TREATED
OMISSIONS, OR INCONSISTENCIES IN THE CONTRACT
NOTIFY CONSULTANT IF AREAS OF FRAMING REPAIR FOUND THAT MAY REQUIRE ENGINEERED
WOOD
DOCUMENTS; HOWEVER, REPORT ERRORS, OMISSIONS, OR
TEMPORARY SHORING. IT IS ASSUMED THAT THE EXISTING SHIPLAP SHEATHING DOES NOT PROVIDE
FURR
FURRING OR FURRED
INCONSISTENCIES DISCOVERED BY THE CONTRACTOR
RESISTANCE TO LATERAL DISPLACEMENT AND FIRE TREATED SHEATHING IS TO BE INSTALLED TO
GA.
GAUGE
PROMPTLY TO THE CONSULTANT AS A REQUEST FOR
IMPROVE BOTH SEISMIC AND FIRE PERFORMANCE OF THE WALL SYSTEM
GALV.
GALVANIZED
INTERPRETATION IN THE FORM PROVIDED IN THE PROJECT
• REVIEW REPLACED SHEATHING AND FRAMING WITH THE BUILDING INSPECTOR AS REQUIRED BY THE AHJ
G.W.B.
GYPSUM WALL BOARD
MANUAL.
PRIOR TO COVER.
GYP.
GYPSUM
6.
REPETITIVE FEATURES, REGARDLESS OF ORIENTATION, NOT
• SHEAR WALLS FOUND THROUGH THE COURSE OF CONSTRUCTION THAT REQUIRE REPAIR, WILL BE
HORIZ.
HORIZONTAL
SHOWN ON DRAWINGS SHALL BE COMPLETELY PROVIDED AS
IDENTIFIED, AND REVISED PLANS AND DETAILS SHOWCASING HOW THE EXISTING CONDITIONS WILL BE
INT.
INTERIOR
IF DRAWN IN FULL.
REMEDIATED TO MAINTAIN THE INTEGRITY OF THE SHEAR WALL(S) IN QUESTION WILL BE SUBMITTED TO
INSUL.
INSULATION
7.
REPORT DISCREPANCIES IN CONTRACT DOCUMENTS TO
THE CITY OF EDMONDS WASHINGTON FOR REVIEW AND APPROVAL TO SATISFY OSSC, SECTION 1604.4.
MAX.
MAXIMUM
CONSULTANT FOR CLARIFICATION PRIOR TO COMMENCING
MEMB.
MEMBRANE
WORK.
HATCH PATTERN LEGEND
MIN.
MISC.
MINIMUM
MISCELLANEOUS ANEOUS
8.
IMMEDIATELY NOTIFY BUILDING ENVELOPE CONSULTANT
UPON DISCOVERY OF ADDITIONAL UNFORESEEN DAMAGE TO
N.I.A.
NOT IN CONTRACT
IN
EXISTING CONSTRUCTION SCHEDULED TO REMAIN AND THAT
N.T.S.
NOT SCALE
IS OUTSIDE THE CONTRACT. REQUEST A REVIEW. DO NOT
BATT INSULATION CONTINUOUS SOLID LUMBER
O.C.
ON CENTER
COMMENCE RELATED WORK TO NEARBY WORK WITHOUT
(EXISTING SHOWN)
PLY
PLYWOOD
CONSULTANT APPROVAL.
EXISTING CONSTRUCTION INTERMITTENT SOLID LUMBER
OSB
ORIENTED STRAND BOARD
9.
TRADE CONTRACTORS ARE RESPONSIBLE, FOR THE LAYOUT
SCHEDULED TO REMAIN
P.T.
PRESSURE TREATED
OF THEIR OWN WORK, AND TO SEE THAT THEIR WORK
POLY.
POLYETHYLENE
COMES TOGETHER WITH THAT OF OTHERS WITH THE DESIGN
0 CONTINUOUS SEALANT BEAD
WOOD PANEL WALL
R
RADIUS
INTENT IDENTIFIED IN THE DOCUMENTS. REPORT
SHEATHING - THICKNESS AS
REF.
REINF.
REFERENCE
REINFORCED
DISCREPANCIES ON DRAWINGS TO CONSULTANT FOR
/ R
SPECIFIED ®`�
REQ'D
REQUIRED
CLOSED CELL BACKER ROD
10.
TRADEDECISCONTRACTORS MUST ASSURE THEMSELVES THAT
REV.
R.D.
REVERSED
ROOF DRAIN
THEY HAVE THE LATEST DRAWINGS ISSUED FOR
CONSTRUCTION IN THE CONTRACTOR'S OFFICE.
GYPSUM SHEATHING
R.W.A.
RAINWATER LEADER
11.
EMPLOY ORIGINAL JOURNEYMAN TRADESMAN OR ORIGINAL
S.A.M.
SELF ADHESIVE MEMBRANE
INSTALLERS OF NEW WORK TO PERFORM CUTTING AND
SEAL.
SEALANT
PATCHING OF NEW WORK. (IF APPLICABLE)
REPAIR CODE PROVISIONS
N
R
12.
INSTALL INSECT SCREENS AT TOP AND BOTTOM OF FURRING
SM.T
SIMIL
AT ALL OPENINGS IN RAINSCREEN CLADDING UNLESS NOTED
CLASSIFICATION OF WORK: WORK TO OCCUR PER CHAPTER 7 ALTERATION - LEVEL 1
SPEC.
S.O.G.
SPECIFICATION
SLAB -ON -GRADE
OTHERWISE. WHERE VENTILATION IS PROVIDED IN A SOFFIT
• LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING
SST
STAINLESS STEEL
CONDITION, PROVIDE INSECT SCREENS AT ALL GAPS
MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR
STRUC.
STRUCTURAL
BETWEEN MATERIALS.
FIXTURES THAT SERVE THE SAME PURPOSE.
T&G
TONGUE AND GROOVE
• WORK IS NOT TO ALTER INTERIOR FLOOR AREAS EXCEPT AS NEEDED FOR LEVEL 1 REPAIRS.
T.B.A.
TO BE CONFIRMED
• WORK REQUIRED IS NOT TO IMPACT MORE THAN 50% OF THE AGGREGATE AREA OF THE BUILDING.
TEMP.
TEMPERATURE
OPENINGS SUCH AS ROOF PENETRATIONS, DOORS AND WINDOWS ARE TO BE REPAIRED. NO ADDITIONAL
T.O.W.
TOP OF WALL
OPENINGS ARE INCLUDED IN THIS PROJECT (ROOF HATCH ADDED BY SEPARATE PERMIT). REPLACE
TYP.
TYPICAL
ORIGINAL EQUIPMENT WITH NEW AS DESCRIBED IN THESE DOCUMENTS.
U.N.O.
UNLESS NOTED OTHERWISE
• WORK IS TO DEMOLISH AND REPLACE FAILED ENCLOSURE SYSTEMS. REPAIR WORK IS TO CONFORM TO
VERT.
VERTICAL
INFORMATION INCLUDED IN THE PROJECT DOCUMENTS AND THE BUILDING CODE(S) IDENTIFIED ON THIS
V.I.F.
VERIFY IN FIELD
SHEET.
WI
WITH
• DAMAGED FRAMING IS TO BE REPLACED IN -KIND PER THE ORIGINAL CONSTRUCTION DRAWINGS WITH ALL
WIO
WITHOUT
CONNECTIONS, HARDWARE, FASTENERS OR OTHER COMPONENTS SIZED TO MATCH THE INSTALLED AND
W.R.B.
WEATHER RESISTIVE BARRIER
DESIGNED EXISTING SYSTEMS.
&
AND
@
AT
PERMIT RESP
2024-03-18
#
NUMBER/POUNDS
±
PLUS OR MINUS
L
ANGLE
:NO
ES
FULLY SEAL
ALL LAP JOINTS
1/2 IN. VERT FOLDED
END DAMS (NO PIN
HOLES ALLOWED) OR
SOLDERED END DAMS
CHAMFER CORNERS
INSIDE/OUTSIDE CORNER TYPICAL END DAM IN
FOLD AND BUTTON PUNCH METAL FLASHING
NOTE(S):
THIS DETAIL IS CONCEPTUAL AND DESCRIBES DESIGN INTENT. IT DOES NOT PURPORT TO SHOW ALL CONDITIONS. ALL
FLASHING JOINTS AND TERMINATIONS TO BE PERMANENTLY WATERTIGHT.
STEP 1
1. SEAL WIRE PENETRATION WITH SEALING COMPOUND
2. INSTALL ELECTRICAL BOX OR EXTENSION. SHIM BACK
OF BOX TO SUIT DRAINED CAVITY ASSEMBLY.
3. WEATHER CUT WEATHER RESISTIVE BARRIER TO
ALLOW INTEGRATION OF SELF ADHERED MEMBRANE
NOTE(S):
THIS DETAIL IS CONCEPTUAL AND DESCRIBES
DESIGN INTENT. IT DOES NOT PURPORT TO
SHOW ALL CONDITIONS. ALL FLASHING JOINTS
AND TERMINATIONS TO BE PERMANENTLY
WATERTIGHT.
6
RTFID 9
2. CUT WEATHER -
RESISTIVE BARRIER AS
INDICATED. FOLD UP
TO ALLOW
INSTALLATION OF FLEX
WRAP
pkCUT HOLE - Z
FOR PIPE N
1. CUT WEATHER -RESISTIVE
BARRIER: APPLY IN FIELD.
NOTE LOCATIONS OF
PENETRATIONS
SLOPED
TYPICAL LINEAR
FLASHING SPLICE
M
1So SCOPF
SIZE TO RECIEVE
TRIM AT CORNERS
MEMBRANE INSTALLATION:
1. SEAL WEATHER -RESISTIVE BARRIER TERMINATIONS,
TRANSITIONS, AND LAPS TO CREATE AIR BARRIER.
2. CLEAN AND PREPARE SURFACE PRIOR TO INSTALLATION OF
ALL MEMBRANES IN ACCORDANCE TO MANUFACTURERS'
RECOMMENDATIONS OR AS DIRECTED BY CONSULTANT.
3. PROVIDE SADDLE FLASHING AT INTERSECTIONS AT
BALCONY/ROOF PARAPET AND WALL; BALCONY EDGE TO
WALL AND ALL SIMILAR TYPE TRANSITIONS THAT MAY OCCUR
WITHIN THE BUILDING ENVELOPE ASSEMBLIES.
METAL FLASHING:
1. ALL JOINTS ARE TO BE LAPPED & SEALED PER THE DETAILS, S-
LOCK OR STANDING SEAMS UNLESS OTHERWISE APPROVED;
FORM INTERNAL & EXTERNAL CORNERS IN METAL FLASHINGS
WITH JOINT ASSEMBLY SHOWN IN DRAWINGS.
2. TERMINATE METAL FLASHINGS WITH FOLDED 1/2 IN. HIGH END
DAMS OR KICKERS. U.N.O.
3. INSTALL METAL HEAD FLASHINGS WITH END DAMS OVER
WINDOWS AND DOORS. EXTEND FLASHING AS DETERMINED
BY CONSULTANT. CONTRACTOR TO FIELD VERIFY THAT
METAL HEAD FLASHING DOES NOT INTERFERE WITH
OPERATION OF WINDOWS OR DOORS.
4. FORM FLASHINGS WITH 15' SLOPE TO DRAIN U.N.O.
EXTERIOR OPENINGS AND PENETRATIONS:
1. NO CONCERTED EFFORT HAS BEEN MADE BY CONSULTANT TO
QUANTIFY THE EXTERIOR FIXTURES, SUCH AS LIGHT
FIXTURES, CONVENIENCE RECEPTACLES, EXHAUST VENTS,
PIPE PENETRATIONS, HOSE BIBS, ELECTRICAL OR METERS,
ETC. CONTRACTOR SHALL PERFORM OWN QUANTITY
SURVEY.
2. INSTALL SEALANT JOINT WITH BACKER ROD AROUND
INTERIOR PERIMETER OF OPENINGS FOR AIR BARRIER
CONTINUITY.
3. FORM EXTERIOR PERIMETER SEALANT JOINTS 3/8 IN. WIDE
WITH CLOSED CELL BACKER ROD U.N.O. MAINTAIN JOINT
WIDTH:DEPTH RATIO OF 2:1.
BEDDING IN SEALANT
SIZE TO ENSURE 1/2 IN. GAP
1/2 IN. HEMMED S-POCKET OR AT TOP OF CLADDING AND
DRIP EDGE BENT THREE (3) BEADS TO ENSURE 1 IN. MIN.
AT 45' ANGLE OF SEALANT COVERAGE OVER CLADDING
.. A . I I A 1- Ir U.N.O.
4. APPLY SELF -ADHERED MEMBRANE AT TOP AND
SIDES OF ELECTRICAL BOX AND EXTEND ONTO
WEATHER RESISTIVE BARRIER IN SHINGLE -LIKE
FASHION. SEAL ALL PINHOLES WITH SELF -
ADHERED MEMBRANE PATCHES.
5. SEAL ALL SELF -ADHERED MEMBRANE EDGES, TYP
4 6. APPLY BEAD OF SEALANT OVER FACE OF SELF -
ADHERED MEMBRANE TO FORM AIR SEAL
BETWEEN MEMBRANE AND WEATHER -RESISTIVE
BARRIER.
3. INSTALL SELF -ADHERING
FLEX WRAP ON BOTTOM
OF PENETRATION AND AS
PRE -WRAP ON PIPE.
4. INSTALL SELF -
ADHERING FLEX WRAP
OVER TOP OF
PENETRATION. LAP OVER
LOWER COURSE
5. APPLY
COMPATIBLE
SEALANT AROUND
EDGE OF SELF -
ADHERED MEMBRANE
STEP 3
TYPICAL FLASHING JOINERY
3" = V-0"
7. FOLD DOWN FIELD WEATHER -RESISTIVE
BARRIER AND APPLY PROPRIETARY SEAM
TAPE.
NOTE(S):
THIS DETAIL IS CONCEPTUAL AND
DESCRIBES DESIGN INTENT. IT DOES NOT
PURPORT TO SHOW ALL CONDITIONS. ALL
FLASHING JOINTS AND TERMINATIONS TO
BE PERMANENTLY WATERTIGHT.
WALL BOX PENETRATION SEQUENCE
3" = V-0" 3
7. FOLD WEATHER -RESISTIVE
BARRIER DOWN AND APPLY
SEAM TAPE OVER CUT EDGE
REFERENCE SYMBOLS / LEGEND
DETAIL NUMBER
f- -1 SIM
1
I I
I ` J I CBS-000- SHEET NUMBER
CBS-00 - SHEET NUMBER
I I
DETAIL REFERENCE(S)
DETAIL TITLE DETAIL NUMBER
1 /4"
TITLE REFERENCE
SIM SECTION DETAIL NUMBER
1
CBS-000 CBS-000 DRAWING NUMBER WHERE DETAIL IS
`�\ DRAWN
DRAWING NUMBER WHERE DRAWING IS
BUILDING SECTION REFERENCED
SIM BUILDING SECTION ALPHA LETTER
1
CBS-000 DRAWING NUMBER WHERE DRAWING IS
LOCATED
WALL SECTION
SIM BUILDING ELEVATION NUMBER
1
CBS-000
DRAWING NUMBER WHERE ELEVATION IS
BUILDING ELEVATION LOCATED
ASSEMBLY TYPE
DESIGNATION
LlBS�
ASSEMBLY TYPE
REFERENCE
EXISTING WINDOW OR SLIDING GLASS OR HINGED
RR > DOOR FOR REMOVAL AND REINSTALL
EX EXISTING WINDOW OR SLIDING/HINGED DOOR TO
REMAIN IN PLACE
NW NEW (REPLACEMENT) WINDOW
NFSD NEW FRENCH -STYLE DOOR
NSGD NEW SLIDING GLASS DOOR
C.5 WINDOW TYPE TAG
OPENING TAGS (WINDOWS & DOORS)
DEMOLTION AND REPAIR NOTE TAGS
PROJECT NORTH ARROW (DIRECTION USER DEFINED)
NORTH
DELTA REVISION INDICATOR CLOUD AROUND
REVISION
1
REVISION CLOUD
- 1 _,,.:",.... - . _ fir!
;afih: i7Txa'�TFI��'r"7.+�.�,:�• ..1tc2.� -.... - �+i.� -- - ' ® 1.
..N Y ri . .
I � I r' I . r -� •r � i v+T' I • $ I''•'•t. sL.iW rntt�K�
DECK ,Y
M- E r M-BATI P;�,
DIN.�r� e Q x:
}fffwfff)fl7tlNfl?+ fArVl 1J'.+,. .j ,
t.........:�............ _ y
>� cirrr r`
,j
\ 0
l' 301 ,' r:: "KIT' J EXISTING RATED
��L �'. WALL ASSEMBLIES
L. Ik' , (PER RECORD
DOCUMENTS)
_ (E)7"X16 t (E)�7"X16 (E)7"X16�� ;(E)7"X16'
f PARALAM PARALAM -' PARALAM - -r PARALAM �■ ■ ■ ■ '
■r■sr■■�I .�
■ a w
11 .■■■■■.■■■■■ I %!HATCH LOCATION ; �
(BY SEPARATE
j .PERMIT)f,�•,.... ♦ � ti l .'111�� �
LIB, _I I O
:
(� 302 . N
-- U)-
:,
3 _ i ~ r'4 1 -'BA FF-I
DECK •» 21, c� ............,
® DIN t,. M:1 D ATH! .E,.
rf tillrYrt' i �1��e1
BED
RIC
Nlt_
1 _t':1
®® ! r:�'e,.lr�-n,c=•:r:l I'll
b�.....r..N,.y,P.N...,� . •.,NCYY� Nnt` i W ♦ .,�1 .. ,T ,
_ i ,
Sri.' '� /cll::�.«,........ e i
LEVEL 3 (E) CONDITIONS/FRAMING PLAN, FIRE WALL LOCATIONS PER
RECORD DOCUMENTS
FULLY
WATERPROOFED
COPING BELOW
6. INSTALL CONTINUOUS
SEALANT PRIOR TO
AT EXTERIOR SIDE,
WEATHER RESISTIVE
CONTINUOUS SHEET
N BARRIER INSTALLATION
METAL CLEAT
r-
w
m
LOW SIDE IF
SLOPED
TYPICAL LINEAR FLASHING
SPLICE AT COPING
NOTE(S):
THIS DETAIL IS CONCEPTUAL AND DESCRIBES DESIGN INTENT. IT
DOES NOT PURPORT TO SHOW ALL CONDITIONS. ALL FLASHING
JOINTS AND TERMINATIONS TO BE PERMANENTLY WATERTIGHT.
NON SKINNING BUTYL
SEALANT. FULLY SEAL LAP
FULLY SEALED, PREFABRICATED CORNER SOLDIER
OR BUTTON PUNCH CONNECTION. MOCK-UP
REQUIRED TO BE APPROVED BEFORE INSTALLATION
SEE DETAIL FOR
PROFILE
FASTENERS PER SPECIFIC
DETAIL. FASTENERS TO BE
GASKETED HEX HEAD NOW
CORROSIVE MATCHING COPING
MATERIAL, LINO. HOLES TO BE
PRE -DRILLED (OVERSIZED OR
SLOTTED) TO ALLOW FOR
EXPANSION AND CONTRACTION
OF COPING.
DRAWING TERMS:
A. DEMOLISH: COMPLETELY REMOVE AND LEGALLY DISPOSE OF OFF -SITE.
B. NEW (ITEM): A TERM USED ON DRAWINGS TO INDICATE THAT AN ITEM IS
PROVIDED AS NEW WORK. ASSUME ALL WORK NOT NOTED AS EXISTING IS
NEW UNLESS ADDRESSED BY ALLOWANCES AND/OR ALTERNATES.
C. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN ITEM
REQUIRES PROTECTION FROM THE WORK.
D. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A SPECIFIC ITEM
TO BE DETACHED FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSED
OF OFF -SITE, UNLESS INDICATED OTHERWISE TO BE REMOVED, SALVAGED,
AND REINSTALLED.
E. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO INDICATE A
SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION,
PREPARED FOR REUSE, AND REINSTALLED BACK IN ITS EXISTING LOCATION.
F. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN EXISTING
ITEM THAT HAS BEEN REMOVED AND TO BE REINSTALLED IN A NEW
LOCATION.
G. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A
MANNER TO PREVENT DAMAGE READY FOR REUSE. INCLUDE FASTENERS OR
BRACKETS NEEDED FOR REATTACHMENT IN ORIGINAL LOCATION OR
ELSEWHERE.
H. EXISTING TO REMAIN (ITEM): A TERM USED ON DRAWINGS TO INDICATE
EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT BE REMOVED AND THAT
ARE NOT OTHERWISE INDICATED TO BE REMOVED, SALVAGED, OR REMOVED
AND REINSTALLED. EXISTING TO REMAIN IS INDICATED BY GRAPHIC
LINETYPE SYMBOL.
PROJECT DATA
DRAWING INDEX
SHEET NAME
A000
INDEX AND GENERAL INFORMATION
A101
ROOF PLAN
A711
DETAILS
OWNER:
ALDERRA CONDOMINIUM HOMEOWNERS ASSOCIATION
OWNER CONTACT:
KERMIT & DANNA
ANDERSON
CERTA PROJECT MANAGER:
JOSEPH CORDES
jcordes@certasolutions.com
PROJECT ADDRESS:
522 ALDER STREET
EDMONDS, WA 98020
PARCEL NUMBER(S):
UNIT 101
00954600010100
UNIT 102
00954600010200
UNIT 201
00954600020100
UNIT 202
00954600020200
UNIT 301
00954600030100
UNIT 302
00954600030200
TAX CODE AREA:
00210
USE CODE:
143 SINGLE FAMILY
RESIDENCE CONDOMINIUM MULTIPLE
COUNTY:
SNOHOMISH
DELEGATED
DESIGN SUBMITTALS
1. NONE
CONTRACTOR TO PROCURE ALL APPROPRIATE PERMITS FROM THE AHJ FOR THESE COMPLETE SYSTEMS.
GENERAL NOTES - PROJECT
1. ALL WORK IS TO COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS INCLDING THE
_2021 WASHINGTON STATE EXISTING BUILDING CODE.
2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO NOTIFY THE ARCHITECT OF ANY CONFLICTING P202
INFORMATION PRIOR TO THE START OF CONSTRUCTION.
3. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS.
4. ALL NEW EXT WALL TO BE BUILT OF 2x6 STUDS @ 16" O.C. (TYP. UNLESS NOTED OTHERWISE).
RECONSTRUCTED WALLS TO BE BUILT OF 2x4 STUDS @ 16" O.C. (TYP. U.N.O.) TO MATCH (E)
5. ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN
450.
6. HANDRAILS ARE REQUIRED ON ALL INTERIOR OR EXTERIOR STAIRS WITH 4 OR MORE RISERS.
7. COLUMN DIMENSIONS ARE AS FOLLOWS:
A. COLUMNS: TO CENTERLINE OF COLUMN
B. WOOD WALLS: FACE OF FRAMING UNLESS NOTED OTHERWISE
C. CONCRETE: FACE OF FINISHED CONCRETE
F
8. CER A B ILD NG OL TIONS H S P OVI ED UIL ING EN LOS RE OC ME TS HA , PE TH PROFE SIO AL UD ME T 0
� THE STAMPING ARCHITECT OF THE DRAWING SHEETS LISTED IN THE INDEX ON THIS SHEET ARE APPROPRIATE TO SATISFY THE
REQUIREMENTS OF RCW 64.55.005. FURTHER, CERTA BUILDING SOLUTIONS WILL PROVIDE ENVELOPE INSPECTIONS DURING
CONSTRUCTION. AS SUCH, CERTA BUILDING SOLUTIONS WILL PROVIDE ENVELOPE ENCLOSURE SERVICES TO SATISFY THE
REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090.
PERMIT RESP
2024-03-18
GENERAL NOTES - SHEAR AND FIRE WALLS
0
Z3
0
LU
www.certasolutions.com
REVISIONS
PERMIT RESP 2024-03-18
1. SHEAR WALLS (WHERE OCCUR) FOUND THROUGH THE COURSE OF CONSTRUCTION WILL BE IDENTIFIED TO THE ARCHITECT. AS
REQUIRED, REVISED PLANS AND DETAILS IDENTIFYING HOW THE EXISTING CONDITION(S) WILL BE REMEDIATED TO MAINTAIN THE
INTEGRITY OF THE SHEAR WALL(S) IN QUESTION WILL BE SUBMITTED TO THE AHJ FOR REVIEW AND APPROVAL PER SECTION
107.2.1.
2. UNIDENTIFIED FIRE-RESISTANT RATED WALLS FOUND THROUGH THE COURSE OF CONSTRUCTION WILL BE IDENTIFIED TO THE
ARCHITECT. AS REQUIRED, REVISED PLANS AND DETAILS IDENTIFYING HOW THE EXISTING CONDITION(S) WILL BE REMEDIATED
TO MAINTAIN THE INTEGRITY OF THE FIRE-RESISTANT RATED CONSTRUCTION IN QUESTION WILL BE SUBMITTED TO THE AHJ FOR
REVIEW AND APPROVAL PER SECTION 107.2.1.
3. WHERE EXTERIOR WALLS (SHEAR, FIRE OR GENERAL USE) WALLS ARE FOUND TO HAVE DAMAGE THAT CANNOT BE TRACED TO A
DEFINITIVE LEAKAGE SOURCE, THE AREA IS TO BE REVIEWED WITH THE ARCHITECT/CONSULTANT PRIOR TO DAMAGED
SHEATHING REMOVAL. DO NOT PROCEED WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/CONSULTANT.
GENERAL NOTES - ENERGY CONSERVATION
CODE: 2018 WASHINGTON STATE ENERGY CODE
CLIMATE ZONE: 4C
BUILDING DESIGN CRITERIA
GENERAL: CONFORMANCE WITH CURRENT CODE NOT REQUIRED AT EXISTING COMPONENTS NOT IMPACTED BY THE WORK
DESCRIBED IN IN THESE DOCUMENTS. NEW COMPONENTS AND ASSEMBLIES ARE TO CONFORM TO NEW CODE PERFORMANCE
VALUES.
SPACE CONDITIONING
RESIDENTIAL SPACE: EXISTING WITH NO CHANGES TO INTERIOR OF UNIT
STORAGE SPACE: NOT PROVIDED
GLAZING: PER ASHRAE 90.1 TABLE 5.5-4 (NEW UNITS AT LIGHTWELL ONLY)
INSULATED GLAZING UNITS: U-VALUE FIXED UNITS: 0.36, OPERABLE UNITS: 0.45
VT/SHGC MAX. 0.33, - MIN. 1.10
AIR LEAKAGE 0.20 CFM/FT2 WINDOWS AND SLIDING GLASS DOORS APPROVED
PLANS MUST BE
DOORS: PER TABLE C402.4 ON JOB SITE
INSULATED GLAZED ENTRY DOOR: N/A (E) TO REMAIN
INSULATION ALL WORK SUBJECT
(E) WALL AT RESIDENCE: 2x4 OR 2x6 R-15 MIN - INSULATION TO FILL CAVITY DEPTH
(E) ROOFING GANG NAIL TRUSSES - R-49 BATT TO FIELD
INSPECTION FOR
NOTES: CODE COMPLIANCE
1. PROVIDE VAPOR RETARDERS PER CODE AND AS IDENTIFIED IN DOCUMENTS.
CODE SUMMARY
1. EXISTING BUILDING IS
2. OCCUPANCY CLASSIFICATION: R-2
Cn
OWN
Maple St
Suite 100
D
m
Cn
City
Of Edmonds
Building
Department
Work
ROOF REPAIRS
AddreCA
<
522 ALDER ST
(D,
Owner
ALDERRA CONDOS
Approved Date
4/02/2024
Buildin§ Official
ofALasz
Permit Number
BLD2023-0791
- - - - - -Ad�st Alder St A THIRD PARTY INSPECTION IS TO BE
s ' COMPLETED BY THE ARCHITECT OF
AREA OF ; RECORD TO PROVIDE A BUILDING
ROOFING WORK I ENCLOSURE REPORT AND THAT IT
' MEETS THE REQUIRMENTS OF RCW 1
BcckLn ��������i BeckL Betk n
64.55.005 THROUGH 64.55.090
------------------ - - - - -
'
O
In
VICINITY MAP
Walnut St
O
J
W
O
Zz
0
a
O U
O
V�
C/) (z)
W o
w�
Q w 3:00
00
=z
0
�o H
z u' W
W�w�
0 o ; ~
U C
w
< G
Q 0 (V W
J A
11603
REGISTERED
ARCHITECT
w`AAS ILEY
STATE OF WASHINGTON
CHECKED BY: JHR
ISSUE DATE: 22 JUNE 2023
PROJECT NO.: WA22-021
INDEX AND
GENERAL
RESUB INFORMATION
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT AOOO
M
N
O
N
H
2
f1'
}
i1
O
U
z
O
J
O
C0
CD
z
0
J_
m
lY
LU
U
TYPICAL WALLS
07 6200 PRE -FINISHED STANDING -SEAM
METAL ROOFING
07 6200 3/4 IN. G90 METAL FURRING
07 2500 WEATHER RESISTIVE BARRIER -SA
06 1000 EXISTING PLYWOOD, REPAIR PER
061000
06 1000 EXISTING FRAMING, REPAIR PER
061000
07 2100 EXISTING BATT INSULATION.
REPAIR PER SCOPE OF WORK
09 2116 EXISTING GYPSUM BOARD,
REPAIR PER ALLOWANCE
A
�
y� •,
,�.
V
TYPICAL WALLS
'-77777—
u
ii A n q
u u u
n
07 5400 SEALANT PER MEMBRANE MFR.
07 5400 SEALANT PER MEMBRANE MFR.
07 5400 STAINLESS STEEL BAND 1/4"
BELOW TOP OF MEMBRANE EDGE
07 5400 SINGLE PLY MEMBRANE FLASHING
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING PROTECTION
BOARD
m
m
r
D
z
Cn
REMOVABLE SCREEN
-1 - - - - - -
07 5400 SEALANT PER MEMBRANE MFR.
07 5400 STAINLESS STEEL BAND 1/4"
BELOW TOP OF MEMBRANE EDGE
07 5400 SINGLE PLY MEMBRANE FLASHING
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING PROTECTION
BOARD
Cn
m
m
D
z
Cn
z�
0
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING PROTECTION
BOARD
07 5400 POLYISO INSULATION
R-49. THICKNESS —15"
07 5400 VAPOR BARRIER
06 10001/2 IN. PLYWOOD
REMOVE AND REPLACE DAMAGED MATERIALS
06 1000 FRAMING, REF STRUCTURAL
07 2100 BATT INSULATION
REPLACE DAMAGED MATERIALS
PIPE PENETRATION/PIPE SUPPORT
09 2423 PORTLAND CEMENT STUCC
FINISH COAT
09 2423 DRAINAGE MAT
07 2500 WEATHER RESISTIVE BARR
06 1000 EXISTING PLYWOOD, REPAI
061000
06 1000 EXISTING FRAMING, REPAIF
061000
07 2100 EXISTING BATT INSULATIOI`
REPAIR PER SCOPE OF WORK
09 2116 EXISTING GYPSUM BOARD,
REPAIR PER ALLOWANCE
3" = 1'-0"
07 5400 POLYISO INSULATION
07 5400 VAPOR BARRIER
06 1000 1/2 IN. PLYWOOD
TYP PIPE PENETRATION n
" ` 3" = V-0t
SHOP FABRICATED, FULLY -SOLDERED 22 GAUGE
STAINLESS STEEL VENT UPSTAND
GRAVITY DAMPER
07 5400 SEALANT PER MEMBRANE MFR
PIPE PENETRATION/PIPE SUPPORT
26 GAUGE STAINLESS STEEL CIRCULAR
FLASHING RING ABOVE PVC ROOF - PROVIDE
GUMLIP PROFILE AT TOP
07 5400 POLYISO INSULATION
07 5400 VAPOR BARRIER
06 10001/2 IN. PLYWOOD
PROVIDE AIR -TIGHT CONNECTION FROM
DUCT TO REMAIN TO NEW UPSTAND
3" = 1'-0"
BOX DRAINS ROUTED TO ROOF BELOW, TYP. RELOCATE TO
POSITIONS FIELD LOCATED WITH CONSULTANT
®
ROOF DRAIN AND OVERFLOW. VERIFY PIPES ARE CLEAR
AND READY FOR NEW WORK
14F��16"
PANEL, STANDING SEAM METAL ROOFING APPLIED
OVER HIGH TEMP SELF -ADHERED MEMBRANE
UNDERLAYMENT
OVERFRAMED ROOF AREA. SEE PLANS FOR
a
OVERFRAMING AND SHEATHING INFORMATION
2X6 FRAMED WALL SET DIRECTLY ABOVE EXISTING
FRAMED WALLS
ROOF TIE -OFF ANCHORS
1. DETAILS ARE TYPICAL UNLESS NOTED OTHERWISE
2. ALL UNBACKED METAL FLASHING INCLUDING, BUT NOT LIMITED TO,
THROUGH -WALL FLASHING AND FLASHING AT CASINGS SHALL BE 22-
GAUGE METAL OR THICKER AND HAVE A BAKED ON OR PREFINISHED
COATING TO MATCH THE CLADDING OR THE TRIM WHERE APPLICABLE.
3. FOR ALL FFSAM, ENSURE FULL ADHESION TO CONTINUOUS SUBSTRATE.
APPLY SEALANT AS NECESSARY TO ELIMINATE EDGE CURL.
4. ROOF SLOPES SHOWN FOR GENERAL ELEVATION COORDINATION ONLY.
ROOFING CONTRACTOR TO FINALIZE DRAINAGE PLAN AND NOTIFY
CONSULTANT WHERE ELEVATIONS NOTES ARE EXCEEDED.
5. ELEVATIONS NOTED ARE FROM TOP OF PROTECTION BOARD.
6. ROOFING INSULATION THICKNESS TO BE FULL CODE REQUIRED R-VALUE
,1OVER SLOPED ROOF ASSEMBLY.
7. REINSTATE IMPACTED GYPSUM BOARD ASSEMBLIES AT UNDERSIDE OF
ROOF PER Gypsum Association GA File No. RC 2601.
GYPSUM WALLBOARD, WOOD JOISTS, ROOF COVERING
Base layer s/e" type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24"
o.c. with 1114" Type W or S drywall screws 24" o.c. Face layer No" type X gypsum
wallboard or gypsum veneer base applied at right angles to joists with 17/e" Type W or
S drywall screws 12" o.c. at joints and intermediate joists and 11/2" Type G drywall
screws 12" o.c. placed 2" back on either side of end joints. Joints offset 24" from base
layer joints. Wood joists supporting 112" plywood with exterior glue applied at right angles
to joists with 8d nails. Appropriate roof covering. Ceiling provides one hour fire
resistance protection for framing, including trusses.
Approx. Ceiling
Weight: 5 psf
Fire Test: FM FC 172, 2-25-72:
ITS, 8-6-98
=D
=Y
O
O
UJ
www.certasolutions.com
REVISIONS
PERMIT RESP 2024-03-18
O
Q
J
Q
UJ
ltttttttttttti
O
ZZ
O
O O
O
Vco
o
CV
W co
Q o
5N
oz
=z
�o
Z w W
UULU
Q z
O
U C
Jof w C � 0 nc
QwQW
0 N
J
Q � LL
11603
REGISTERED
ARCHITECT
0
STATE OF WASHINGTON
'LA�J CHECKED BY: JHR
" = 1'-0" ISSUE DATE: 22 JUNE 2023
PROJECT NO.: WA22-021
c+M
RESUB
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ROOF PLAN
Al 01
M
N
O
N
C7
a
O
U
v7
z
O
J
O
v7
CD
Z
J
m
Q
ry
w
U
cn 07 5400 SINGLE PLY MEMBRANE ROOFING
m
m
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING
PROTECTION BOARD
07 5400 POLYISO INSULATION
07 5400 SINGLE PLY MEMBRANE
FLASHING
07 6200 FLASHING
07 3113 ROOF UNDERLAYMENT
06 1000 2x10 FRAMING
07 6200 PRE -FINISHED STANDING -SEAM
METAL ROOFING
07 3113 ROOF UNDERLAYMENT
07 5400 5/8" EXTERIOR SHEATHING
PROTECTION BOARD
FLAT ROOF TO STANDING SEAM TRANSITION
3" = 1'-0"
�!� ■I■ ■ ■ ■ ■ ■ ■ ■■■■g■�
■■■■■ on ■■■■■
mm
■■■■■■■■■■■■■■■■■■■■■■■■■■■ £0Nis
�'♦11■■■■■�■■■■■■■■■■■■■■■■■■■■■■■■�
■■■■■■■■■■■■■■■■■■■■■■■■■■■ _ �I■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ®
■■■■■■■■■■■■■■■■■■■■■■■■■■■ _ �I■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
♦ - ■■■ ■■■■■■■■■■■ ■■■■®
� �� � '
♦i♦i�®��' �� ♦♦i0♦♦♦♦♦ _
■1■ ■ ■ ■ ■ ■ ■ ■■■■
�� ■■■■■ ■■ ■■■■■
-� I��
_ =
r`�' ®■■■■■■■■■■■■■■
_ \� i�\®�♦�♦ ®■■■■■■■■■■■■■■■■■
�♦♦♦♦
® '�9 i� ���♦�♦♦ � e°•�
�■■■■■■■■■■ 1 11'• • • ■■■■■
■■■■■■■■■■ ■■■■■
■■■■■■■■■■■■■ ■■■■■
■■■■■
■■■■■■■■'■■■■
�� � :� mac: c:� :c�c?� _=
�iiGiiGoGii�iiGii�ii��i�
■■■■■■
■■■■■■
■■■■■■
■■■■■■■I�■■■■■■■■■■■■■■■■■■■■■■■■►�I■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■'
■■■■■■■■■■■■■■■■■■■■■■■■■■®®\,�i
�� c:�a�c�co�
♦i�♦�♦�♦�♦�♦�♦�� ��Oi♦i♦i♦i♦i♦i♦i♦i
��i♦i♦i♦i♦i♦i♦i♦i♦i♦i
ROOF/OVERFL
3" = 1'-0"
07 6200 PRE -FINISHED STANDING -SEAM
METAL ROOFING
07 3113 ROOF UNDERLAYMENT
07 5400 5/8" EXTERIOR SHEATHING
PROTECTION BOARD
07 5400 POLYISO INSULATION
07 5400 VAPOR BARRIER
06 1000 1/2 IN. ROOF SHEATHING
PER SCOPE OF WORK
06 1000 EXISTING FRAMING, REPAIR
PER 061000
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING
PROTECTION BOARD
n7 CAnn\/A DnD DAoo I ED
07 6200 FLASHING -TYPE 12
07 2500 SELF -ADHERED MEMBRANE -
HIGH TEMP
09 2423 STUCCO CASING BEAD
09 2423 PORTLAND CEMENT STUCCO
WITH FINISH COAT
07 2500 SELF -ADHERED MEMBRANE - HIGH
TEMP
061000 EXISTING FRAMING, REPAIR
PER 061000
07 2119 FOAMED IN PLACE INSULATION
APPLIED FROM UNDERSIDE OF EAVE
TO NEWLY INSTALLED OR SUITABLY
PREPARED REUSED PLYWOOD
09 2423 WEEP SCREED
07 6200 FLASHING -TYPE 8
07 2500 SELF -ADHERED MEMBRANE -
HIGH TEMP
07 2500 WEATHER RESISTIVE BARRIER -SA
07 4646 FIBER CEMENT LAP SIDING
09 2423 EPS FOAM TRIM SHAPE
TO MATCH EXISTING
09 2423 PORTLAND CEMENT STUCCO
WITH FINISH COAT
09 2423 DRAINAGE MAT
07 2500 WEATHER RESISTIVE BARRIER -SA
06 1600 5/8 IN. EXTERIOR SHEATHING -TYPE X
(E) SHEATHING MAY REMAIN WHERE IN
GOOD CONDITION AND SUITABLE FOR
INSTALLATION OF NEW MATERIALS
06 1000 EXISTING PLYWOOD, REPAIR PER
061000
HVAC SHROUD
SEAL HVAC SHROUD TO TOP
OF NEW CURB CAP
07 9200 CONT SEALANT BEAD
07 6200 INTERMITTANT 1/4" HEX HEAD
SCREWS WITH NEOPRENE WASHERS
06 1000 2xl2 FRAMING
07 1413 HOT FLUID APPLIED RUBBERIZED
WATERPROOFING
07 9200 CONT SEALANT BEAD
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING PROTECTION
BOARD
Im
m
m
m
07 5400 POLYISO INSULATION
07 5400 VAPOR BARRIER
06 1000 1/2 IN. PLYWOOD
SKYLIGHT w/ WEEPS - INSTALL W/ SHIMS AT
FASTENERS FOR DRAINAGE
07 9200 CONT SEALANT BEAD
07 6200 INTERMITTANT 1/4" HEX HEAD
SCREWS WITH NEOPRENE WASHERS
07 6200 INTERMITTANT SHIM
06 1000 2xl2 FRAMING
07 1413 HOT FLUID APPLIED RUBBERIZED
WATERPROOFING
07 9200 CONT SEALANT BEAD
07 5400 SINGLE PLY MEMBRANE ROOFING
07 5400 EXTERIOR SHEATHING PROTECTION
BOARD
O7
m
m
r
D
Z
O7
TYPICAL ROOF EDGE Cl
3" = 1'-01,
SLOPE — — —
in
TYP MECH CURB 2
3" = l'-0"
SLOPE
N
W
www.certasolutions.com
REVISIONS
m
O
ZZ
O
Q
O
O
O
V�
�CD
Of CD
LLI co
Q
o
�2iz
o0
=z
�o
Zw
W
W
Ow
N
Q
JofoW
U
c
w
�
C
C
Lu Q
CV
W
Q
J
Q �
LL
11603
REGISTERED
ARCHITECT
a
'ANTES ILEY
STATE OF WASHINGTON
CD
CHECKED BY: JHR
ISSUE DATE: 22 JUNE 2023
PROJECT NO.: WA22-021
c+M
07 5400 POLYISO INSULATION
07 5400 VAPOR BARRIER
06 1000 1/2 IN. PLYWOOD
TYP SKYLIGHT CURB n
3" = 1'-0"
RESUB
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
DETAILS
A701