REVIEWED BLD2023-1489+Energy_Calculations+11.20.2023_1.15.39_PM+3910731E=VERI EDC E
Compliance Affidavit
Washington State Energy Code 2018 C410.2 - Walk -In Coolers and Walk -In Freezers
Install Date: 05/22/2023
Model#/ Serial#: IDT 1019 / 126349
Customer Name: Arby's #769
Installed Location: 8425 255th ST SW Edmonds, WA 98020
New Construction: X Remodel:
REVIEWED
BY
CITY OF EDMONDS
RECEIVED
Dec 01 2023
CITYEEDMONDS
DEVELOPMENT
SERVICES
DEPARTMENT
BLD2023-1489
Compliance Data *(please note that walk-in may or may not be equipped with glass doors, anti -sweat frame heaters,
or refrigeration — equipment is compliant if so equipped as supplied by Everidge)
C410.2 Walk -In Coolers and Freezers, Refrigerated Warehouse
Cooler and Freezer
1) Automatic Door Closers on Doors width < 45" or Height < 7'
2) Method of minimizing infiltration (strip doors, spring hinges)
3) Insulation- Wall, Ceiling, Door
Cooler 2:R-25 (actual @ 4" thick = R29)
Freezer zR-32 (actual (@_4" thick = R33)
4) Insulation- Floors
Cooler 2:R-25 (actual at 4" thick = R29)
Freezer 2:R-28 (actual at 4" thick = R33)
5) Transparent Fixed Windows and Reach -in Doors
Freezers — 3 Pane Gas Fill or Heat Reflective Glass
6) Transparent Fixed Windows and Reach -in Doors
Cooler — 2 Pane or 3-Pane Gas Fill or Heat Reflective Glass
7) Evaporator Fans < 1 hp and < 460V
Electronically Commutated, brushless DC or 3-Phase Motors
8) Condenser Fans < 1 hp
Electronically Commutated, PSC or 3-Phase Motors
9) Antisweat Heater / No Controls
Freezer Frame Heater < 7.1 W/ft2 (76 W/m2) (Actual
5.64W/ft2)
Cooler Frame Heater 5 3.0 W/ft2 (32 W/m2)
10) Antisweat Heater with Controls as function of %RH outside to
in
11) Light Source
Efficacy z 40 Lumens Per Watt (LED's = 139 LmW
Efficacy < 40 Lumens Per Watt w/ Timer
C410.2.1 Performance Standards
1) Display
Doors
a)
Display Med Temp Max kWh/day (2.376 Actual)
b)
Display Low Temp Max kWh/day
2) Non -Display Doors
a)
Passage Med Temp Max kWh/day (3.45 Max Allowable)
b)
Passage Low Temp Max kWh/day (9.70 Max Allowable)
c)
Freight Med Temp Max kWh/day
d)
Freight Low Temp Max kWh/day
3) Refrigeration Systems
a)
Dedicated CU, Med Indoor AWEF >_ 5.61
b)
Dedicated CU, Med Indoor >9000 Btu/h AWEF > 5.61
c)
Dedicated CU, Med Outdoor AWEF >_ 7.60
d)
Dedicated CU, Med Outdoor >9000 Btu/h AWEF >_ 5.61
Conformity
==0
��
OO
��
00
00
��
00
00
��
00
��
��
00
00
��
00
ikWh/day
Compliance Data Completed By: Randy Helbert Engineer / Everidge Date: September 25, 2023