REVIEWED RESUB 2-BLD2023-1489+Tie Downs+5.22.2024_12.23.22_PM+4274969PARTS - L-12 TIE -DOWN
A) L12 ALUMINUM TIE -DOWN (ALLOY 6061 OR 6063) - QTY(MINIMUM OF 4)
B)1/2"x 4"x V-0" COVER - QTY(1 PER TIE -DOWN).
MATERIAL: .040" ALUMINUM / 26 GA GALVANIZED STEEL STUCCO EMBOSSE
(COLOR TO MATCH EXTERIOR).
C)1/4"xl-1/4" HEX HEAD TEK SCREW - QTY(10 PER TIE -DOWN).
D) ADHESIVE TAPE - QTY (8 FT)
E) HILTI HVA ANCHOR WITH HEA 3/4"x6-5/8" ADHESIVE CAPSULE & HAS
SS34-958 ANCHOR ROD ASSEMBLY - (PROVIDED BY OTHERS)
WALK-IN
1/4'xl-1/4' HH EXTERIOR
TEK SCREW
(TYP 10) /\
ANCHOR -
TIE -DOWN
STEP 1 & 2:
REVIEWED
BY
CITY OF EDMONDS
MINIMUM CONCRETE
EMBEDMENT 6 J"
;ONCRETE
SLAB
ADHESIVE
TIE -DOWN
COVER
L-12 TIE -DOWN
BLD2023-1489 RESUB
May 22 2024
DEPARTMENT
STEP 3 & 4:
4'
-12 TIEDOWN
° o J'Xl-1/4' HEX
10' WASHER HEAD SELF
DRILLING SCREWS
(FACTORY SUPPLIED)
4
1j'
. a .
4 a. CUSTOMER SUPPLIED
CONCRETE PAD
' DIA. HILTI HIT-Z ROD WITH HILTI
HIT-HY 200 SAFE SET SYSTEM
HILTI Z ROD (CUSTOMER SUPPLIED)
NOTES:
1. A MINIMUM OF FOUR ANCHORS IS REQUIRED FOR EACH WALK-IN. SEE DWG# TDFPLAN FOR GENERAL LAYOUT.
2. FLOORLESS WALK-INS: ANCHOR FLOORLESS COMPARTMENT(S) PER ICS "FLOORLESS WALK-IN INSTALLATION INSTRUCTIONS" BEFORE
ANCHORING L-12 TIE -DOWN.
INSTRUCTIONS:
STEP 1. PLACE TIE -DOWN AT CORNER OF WALK-IN AND ATTACH TO WALK-IN WITH TEN 1/4"x 1-1/4" HH TEK SCREWS.
STEP 2. WIPE DIRT AND/OR DEBRIS FROM TIE -DOWN AND THE INSIDE OF COVER.
STEP 3. PLACE STRIP OF MACTAC ADHESIVE TAPE ALONG THE VERTICAL EDGES OF THE TIE -DOWN.
STEP 4. PLACE TIE -DOWN COVER OVER THE TIE -DOWN AND PRESS FIRMLY AGAINST THE TAPE FOR SEVERAL SECONDS.
STEP 5. REPEAT STEPS 1 THRU 4 FOR THE REMAINING TIE -DOWNS.
REVISIONS
B 1 07 11 19 1 RH NEW CORPORATE LOGO REVISED MATERIAL
L-12 TIE -DOWN INSTALLATION
THIS DRAWING IS THE PROPERTY OF INTERNATIONAL ITM INSTRUCTIONS
COLD STORAGE. IT IS NOT TO BE ALTERED OR
cs
DISTRIBUTED TO OTHERS WITHOUT THE WRITTEN 25 OCT DWG#
APPROVAL OF INTERNATIONAL COLD STORAGE. jy �j GEF 1999 RH TDL12-1