APPROVED RESUB 2-BLD2024-0288+Mechanical_Plan+7.13.2024_3.58.47_PM+43758931.2 EXHAUSTHINDGE KIT FIREMASTER GREASE DUCT SYSTEM: NOTES: 1 OR 2 HOUR SHAFT ALTERNATIVE & ZERO 1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE INSTALLATION CLEARANCE TO COMBUSTIBLE CONSTRUCTION CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH 4Wf FOR SAME TIME OPERATION.Uj F 3 1 6 2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL r r 'a a r_ 2 3 BE AS SPECIFIED OR EQUAL. ,� Y2" THREADED �+ 3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE o STEEL ROD .� rj 4'-6" (FRONT SUPPORT) V f'" ' CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD). 17- 4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE NHS nA HANGING COOKING AREA. �'�Y �,j i 6" VAPOR PROOF BRACKET O LL 4 =t� C N 16 GA. GALVANIZE '� GLASS LIGHT 5. ALL HOOD DUCT JOINS & SEAMS SHALL BE EXTERNAL 10" FIXTURE 10" F ca p EXHAUST COLLAR "s" `•� "'r GREASE TIGHT WELD. �� , ` (EXHAUST DUCT TO BE MAKE E U .',,r : 11 'Q' r. `` `;�. 6. EXHAUST FAN SHALL BE 40 (MIN.) DISCHARGE ABOVE ROOF. DouBLE LAYER UP AIR COLLAR O J t`. FIRE BARRIER WRAPPED 1' 7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR ,,9 ) MAKE UP AIR BOX Q `` o 1 vi �•,� SHALL BE NO LESS THAN 10'. :�&� P�F -�._ 2' w/ PERFORATED p � O ,�►� SHEET @ BOTTOM = Q ' •- 8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT. `- ' ' �a� .,m' c�= v W W o h r+�Fsr�ux".��� 3" STAINLESS STEEL �� Rw, , '\-S/S FILTER Q i ® 7 SCOPE OF WORK: �, -1 M� I (20 GA.) FLASH *0 Q Q THREADED ; f -;I 18 GA. STAINLESS U) �* N INSTALLING ONE TYPE I EXHAUST HOOD SYSTEM '�`` �'•• L: � ® CABLE WITH MAKE AIR WITH RELATED DUCT WORK STEEL TYPE I �' y Uj METAL STUD GREASE • � ,� `=�'. i ' a WALL FRAME GUTTER EXHAUST HOOD d M ® 1 2 LAYER FIREMASTER DUCT WRAP PROJECT INFORMATION: �,N� , B� ,,, c r' % _ , SYSTEM E v _ ® TENANT: GYRO MAKERS � t � 0 TRASH DICLGSUPE 3'_g�� 3 '� � cA FILAMENT TAPE _ _ , •_1 FIRE RATED Cr �+ _ ROOF 2 �.� ncf I 5/8" TYPE "X" HINDGE CURB 3 BANDING 10016 EDMONDS WAY # A ,_ f BRACKET EDMONDS, WA 98020 a �._/- PROPEHrruNE _ -'{ a SHEET ROCK 4 3" PERIMETER OVERLAP PARCEL NUMBER: 00610700200803 - LEGAL DESCRIPTION: Section 36 Township 27 Range 3 Quarter NW - " : ,: ' 6 $ ROOF LINE GREASEs-,Q 5 3" LONGITUDINAL OVERLAP WESTGATE PARK DIV 2 BLK 002 D-03 LOT 2 PER CITY OF ED LLA JOBSITE •¢ ram• • _ �,�,. ,��' es , ,L. 22 GA. STAINLESS � DUCT PLN 20170048-BLA REC AFN 201711085004 BEING A PTN OF LOTS ,'I�!� 1.325 SOFT. a � SOTE DUSTINGADAPARKINGTRAVELDISTANCE STEEL WALL PANEL 6 1/2" DIAMETER HANGER ROD 7, 8, 9, & 10 EXST PLAT _ .. NISESLOPE M�iNANYoIRETlo9`GE55 COOKING 1 1/2" x 1 1/2" x 1/8" ANGLE '-- P ; 3" AIR SPACE EQUIPMENT NORTH 7i VICINITY MAP SCALE: N,T.S ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE EXISITNG EXHAUST FAN (LOCATED ON ROOFTOP) J OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES EXISTING MAKE UP AIR (LOCATED ON ROOFTOP) EXISTING TYPE I HOOD (LOCATED INSIDE) . The following documentation shall be available on ' site for the building inspector: ❑ COE APPROVED ARCHITECTURAL PLAN SET ' : ❑ COE APPROVED STRUCTURAL PLAN SET ❑ COE REVIEWED CALCULATION PACKET = ❑ ENERGY CREDIT WORKSHEET '. ❑ SITE PLAN ❑ CIVIL PLAN :❑ :❑ ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 SITE / ROOF PLAN SCALE: %4" = 1' NORTH APP OVED PLAN MUST BE ON JOB SITE APPROVED BY PLANNING Jul 15 2024 Noise generated by mechanical equipment must meet the standards in ECC 5.30 0 SECTION ELEVATION VIEW SCALE: Y2" = 1' FAN EQUIPMENT SCHEDULE BRAND CFM HORSE ELECTRICAL WEIGHT UNIT NAME MODEL # (REQUIRED) POWER S P (VOLTAGE)/(PHASE) (LBS) d.B.A. TYPE I ECON-AIR 2,400 NA NA NA 366 NA HOOD EX-2-PS EXHAUST ECON-AIR EADU85H 2,400 1 .85 (115/208-230)/(1 PH) 103 68 d.B.A. FAN MAKE UP ECON-AIR EA-A2-20D 2,160 1 0.511 (115-230)/(1 PH) 244 65 d.B.A AIR MIN.40" 20'-3" SEE 1.2 THERMAL CERAMICS FIRE BARRIER DOUBLE LAYER EXHAUST DUCT WRAP 12 GA. "U" CHANNEL BAR SUPPORT 17" x 17" ALL AROUND CONTINUOUS TIGHT WELDED GREASE DUCT (16 GA. GALVANIZE STEEL) 24 GA. GALVANIZE MAKE UP T TO BE ADDED ONTO }� TING & SHARE MAKE UP AIR NIT �Iier-iiiits ;-)eparate gas piping, alarm and supprez reiwtjir&.4`.' ' I I * I .Ayi • •Permit.Com 0 City Of Edmonds Building Department Work MECHANICAL FOR TYPE 1 HOOD ---------------------------------------------------------------- ---------------------------------------- Address 10016 EDMONDS WAY #A -------------------------------------------------------------------- Owner ' GYRO MAKERS Approved Date 07 24 4 -------------- Building Official Elul c/Cvwter ---------------------------- ---- Permit Number BLD2024-0288 "THREADED STEEL ROD 7IONT SUPPORT) 20 GA. FLASHING O 6" MIN. OVER HANG 1 '-2" O EXHAUST FAN 10, 0 0 FRONT VIEW SCALE: Y2 = 1' MOTORIZED DAMPER SERVING THE MUA WILL BE A LOW LEAK (4 CFM/SQFT), CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSES DURING UNOCCUPIED HOURS 1 '-2" 1'-4" MIN. 10' MAKE UP HEATING FAN MODULE 12" THREADED STEEL ROD (FRONT SUPPORT) V-6" 6" MIN. OVER HANG MOTORIZED DAMPER SERVING THE MUA WILL BE A LOW LEAK (4 CFM/SQFT), CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSES DURING UNOCCUPIED HOURS 22 GA. STAINLESS STEEL WALL PANELS EQUIPMENT 1. TYPE 1 HOOD SYSTEM <4'(W) x 10'(L)> 2. DEEP FRYER <16"(W) x 43"(H)> 3. VERTICAL BROILER <14"(W) x 32"(H)> 4. FLAT GRIDDLE <36"(W) x 12"(H)> 5. TWO BURNER RANGE <12"(W) x 23"(H)> 0 H U Q F_ z 0 L) 0 LL a LLI U) 0 a 0 I— V LLI a C/) Q L � o �o rn G C: o0 C: � w o co E �n o w v RESUB Jul 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER FOR QUESTIONS, CALL THE PATENT NUMBERS Seattle Offlce AC-PSP (UNITED STATES) - US PATENT 7963830 B2. REGION 85 AC-PSP WALL (CANADA) - CA PATENT 2820509. PHONE, (425) 212 - 5996 AC-PSP ISLAND (CANADA) - CA PATENT 2520330. EMAIL, reg852econalr.con 9152 MAX EXHAUST PLENUM TOTAL HOOD CONFIG RISERS) MODEL M NUFACTUR RLENGTH COOKING TYPE APPLIANCE DESIGN TOTAL SUPPLY HOOD END TO WIDTH LENG HEIGHT DIA CFM VEL SP TOD TEMP DUTY CFM/FT EXH CFM CFM CONSTRUCTION END ROW 5412 ECON-AIR 10, 0' 600 I HEAVY 250 2500 10, 24' 4' 2500 1500 -0.365' 2000 430 SS ALONE ALONE ESX-2-PSP-F DEG WHERE EXPOSED FILTER(S) LIGHTS) UTILITY CABINETS) HOOD TAG EFFICIENCY E 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM HOOD HZYNE NO TYPE QTY HEIGHT LENGTH MICRONS QTY TYPE GUARD LOCATION SIZE PIPING WEIGHT TYPE SIZE MODEL # QUANTITY I SS BAFFLE WITH 7 20' 16' 30% 3 L55 SERIES E26 NO NO 602 HANDLES LBS WOOD OPTIONS HOOD NO TAG OPTION [RIGHT QUARTER END PANEL 27' TOP WIDTH, 0' BOTTOM WIDTH, 27' HIGH 430 SS. 1 LEFT QUARTER END PANEL 27' TOP WIDTH, 0' BOTTOM WIDTH, 27' HIGH 430 SS. INSULATION FOR TOP OF HOOD. INSULATION FOR BACK OF HOOD. PERFORATED SUPPLY PLENUM(S) HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISERS) WIDTH LENG DIA I CFM I SP 1 Front 120' 14' 6' MUA 12' 28' 666 0.169' MUA 12' 28' 666 0.169' MUA 12, 28, 666 0.169' HOOD CORNER s amm��o (HARDWARE BY INSTALLER) area �c carts vrs MOON" STM MT VASHM area N.L-TNIF.AA area �c cur. vrORMs RATSTM W"M11 m � yr aaa s a E'IE MTT VMIFR GRATE 0 oamw"_ STEEL HEX N= HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. 1' LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. -FIELD CUT TO' X24' EXHAUST RISER. 54' U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE — HIGH TEMP ASSEMBLY. 14' 1 --12' --- 7F;l7' 20' 40' I 40' 10' O'NOM./10' 0.00'OD. PLAN VIEW - HOOD #1 10' 0.00" LONG 5412ESX-2-PSP-F n1J RESUB Jul 15 2024 FULL LENGTH � _ m TF7 HANf.TNf. ANrI GRADE CDR-\ (HARDWARE BY INSTALLER) STEEL STEEL.GRADE I'r - STEEL SUPPLY PLENUM vY - a TPI HANGING ANGLE GRADE x ream (HARDWARE BY INSTALLER) yr GRADE 5 ammEDR GTE MT VANIR. I/E' - 0 TPE GRADE G 0@IDSEO STEEL N.L-TNATA0. L -mm GRADE 5 G@mEAO STEEL HEX NVG. SVPPLT KENN INNWNG ANIX L GRADE 5 QEDRR SEARINS GmmRDR STEEL MT VANIER NXIIN P[@!T NR SIRPLT NETDDDR. Me GRADE 5 0@IDRRD STEEL MT VASTER. L -mm GRADE 3 0@ _ STEEL NIX MN. HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4' OF MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS. ALL HEX NUTS TO 57 FT-LBS. CLEARANCE TO COMBUSTIBLES HOODS # I SURFACE RCLEARANCE I TOP 0' FRONT 0' BACK 0' LEFT 18' RIGHT 18' - NO' CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. RESUB Jul 15 2024 54' L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). 1' LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES, FIELD CUT EXHAUST RISER, ATTACHING FIELD CUT SUPPLY RISER HANGING ANGLE, PLATES. WITH VOLUME DAMPER. HOOD BLE, 23,5. OPEN STAINLESS a aid•I — STEEL PERFORATED PANEL, 20' SS BAFFLE WITH 1' LAYER OF IfRi]NaA� ICY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS, GREASE DRAIN WITH REMOVABLE CUP. LEFT AND RIGHT QUARTER END PANELS. 27' EQUIPMENT BY OTHERS, 27' 12' NOM, 14' i4' 48,0' MAX. 80' 68' SECTION VIEW - MODEL 5412ESX-2-PSP-F HOOD - L9 RESUB Jul 15 2024 EXHAUST FAN INFORMATION — JOB"899152 FAN UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM MOTOR HP BHP PHASE VOLT I FLA DISCHARGE WEIGHT SONES NO ENCL VELOCITY (LBS) I I EADU85H ECON—AIR 1 2400 1 0.850 1 1524 TEAO—ECM 1.000 0.6360 1 1 115 1 11.6 1 759 FPM 1 99 16,6 MUA FAN INFORMATION — JOB#6899152 FAN MIN DESIGN MOTOR WEIGHT UNIT TAG QTY FAN UNIT MODEL # BLOWER HOUSING CFM CFM ESP RPM ENCL HP BHP PHASE VOLT FLA MCA MOCP (LBS) SONES NO 2 1 EAl—D.250-15D 15MF-1—MOD AI—D.250 1000 2000 0.350 2010 ODP,PREMIUM 1.500 1.3120 3 230 4.0 5A 15A 511 19.7 GAS FIRED MAKE—UP AIR UNIT(S) FAN UNIT TAG INPUT OUTPUT TEMP RISE REQUIRED INPUT GAS PRESSURE GAS TYPE BURNER NO BTUs BTUs EFFICIENCY(%) 2 96879 89129 42-F 7 IN. W.C. — 14 IN. W.C. NATURAL 92 OPTIONSFAN FAN UNIT NO TAG QTY DESCRIPTION I HINGE KIT — SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS 1 ECM WIRING PACKAGE — PWM SIGNAL FROM ECPM03 PREWIRE (TELCO MOTOR), CCW ROTATION I 1 GREASE BOX 1 FAN BASE CERAMIC SEAL — DU/DR85HFA — SHIP LOOSE — FOR GREASE DUCTS 1 2 YEAR PARTS WARRANTY 1 ISIZE I TEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS 1 INLET PRESSURE GAUGE, 0-35' 1 MANIFOLD PRESSURE GAUGE, —5 TO 15' WC 1 SHIP LOOSE GAS STRAINER 3/4' 2 1 MOTORIZED BACKDRAFT DAMPER FOR AI—D HOUSING — MEETS AMCA CLASS IA RATING I SEPARATE 120V WIRING PACKAGE (REQUIRED AND USED ONLY FOR DCV OR PREWIRE WITH VFD) — THREE PHASE ONLY 1 2 YEAR PARTS WARRANTY I EXTERIOR GAS CONNECTION PROVIDED BY FACTORY WITH QUICK SEAL AND ANTI —ROTATION BRACKET FAN ACCESSORIES FAN UNIT NO TAG GREASE EXHAUST SUPPLY CUP I GRAVITY DAMPER I WALL MOUNT SIDE DISCHARGE I GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT I YES 2 YES HMI SCHEDULE UNIT NUMBER HMI # HMI LOCATION TEMP AVERAGING I MODBUS ADDRESS FAN #2 1 HMI #1 — UNIT HMI # 1 1 MOUNTED IN UNIT I NOT AVERAGED 55 FAN #1 EADU85H — EXHAUST FAN FEATURES, - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). 31 7/8' - ROOF MOUNTED FANS. - RESTAURANT MODEL. - UL705 AND UL762 AND ULC-S645 - VARIABLE SPEED CONTROL. - INTERNAL WIRING. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 30WF (1491C). - GREASE CLASSIFICATION TESTING. - NEMA 3R SAFETY DISCONNECT SWITCH. 30 1/2' NORMAL TEMPERATURE TEST 23• EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 3001F (1491C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH GREASE DRAIN. WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST 2' EXHAUST FAN MUST OPERATE CONTINUOUSLY 14 7/8• I WHILE EXHAUSTING BURNING GREASE VAPORS AT 6001E (3161C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING - DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, 221/2, OPTIONS 24�'� — HINGE KIT — SHIPS LOOSE FOR \V DUCTWORK BETWEEN CURB SUPPLIED BY OTHERS, EXHAUST RISER ON HOOD — ECM WIRING PACKAGE — PWM AND FAN (BY OTHERS). SIGNAL FROM ECPM03 PREWIRE (TELC❑ MOTOR), CCW ROTATION. — GREASE BOX. — FAN BASE CERAMIC SEAL — 31 7/8' DU/DR85HFA — SHIP LOOSE — 2a 3/4• FOR GREASE DUCTS. — 2 YEAR PARTS WARRANTY. RESUB Jul 15 2024 CITY oc -- TOP VIEW —ELDEPARTMENT ES FAN #2 EAI-D.250-15D - HEATER 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 15' MIXED FLOW DIRECT DRIVE FAN. 2. INTAKE HOOD WITH EZ FILTERS. 3. DDWN DISCHARGE - AIR FLDW RIGHT -> LEFT. 4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 1 DIRECT DRIVE AHUS. 5. GAS PRESSURE GAUGE, 0-35', 2.5' DIAMETER, 1/4' THREAD SIZE. 6. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5' DIAMETER, 1/4' THREAD SIZE. 7. SHIP LOOSE GAS STRAINER. TO BE INSTALLED UPSTREAM OF UNIT CONNECTION. 3/4' CONNECTION. 8. MOTORIZED BACK DRAFT DAMPER 16' X 18' FOR SIZE 1 STANDARD 6 MODULAR HEATER UNITS W/EXTENDED SHAFT, STANDARD GALVANIZED CONSTRUCTMN, 3/4' REAR FLANGE, LOW LEAKAGE, TFB120S ACTUATOR INCLUDED. 9. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL UR WITH DCV PACKAGE. PRDVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH. 10. HINGED DDUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTION). 11. EXTERIOR GAS CONNECTION PROVIDED BY FACTORY WITH QUICK SEAL AND ANTI -ROTATION BRACKET. 12. 2 YEAR PARTS WARRANTY. SUPPLY SIDE HEATER INFORMATION- .NOTE- SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST WINTER TEMPERATURE = 33'F. TEMP. RISE = 42'F. BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD BTUs CALCULATED OFF ACTUAL AIR DENSITY. NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL OUTPUT BTUs AT ALTITUDE OF 0.0 FT. = 89741. DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE INPUT BTUs AT ALTITUDE OF 0.0 FT. = 97544. TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. OUTPUT BTUs AT ALTITUDE OF 189 FT. = 89129. SUGGESTED STRAIGHT DUCT SIZE IS 14' x 14'. INPUT BTUs AT ALTITUDE OF 189 FT. = 96880. 27 3/8' LIFTING LUG. 3 3/4' 6 3/8' I••' FLEX CONIT iDR FD10 VDiDIG. 118 5/8' 32 1/8' 42 1/8' AIRrFLDV. DL CT FIRED MpDULE. 39 9/16' AI4 29 3/4' D1= DLDVEROR 3/4' NET. ACLESS Dp01! 7 13/16-glig 4' SERVICE MINIMUM STRAIGHTDUCT \I PER AMCA. 4 I�r MIN. 14' -60 1 DIRECT FIRED (DF) PROFILE PLATE ASSEMBLY DESCRIPTIGN. PROFILE PLATE DIRECT FIRED BURNERS SHALL HAVE PATENTED (US PATENT NO., US6629523B2), SELF-ADJUSTING PROFILE PLATES DESIGNED TD ENSURE PROPER AIR VELOCITY AND PRESSURE DRGP ACROSS THE BURNER. PROFILE PLATES SHALL ALLDW BURNERS TO ACHIEVE CLEAN COMBUSTION BY LIMITING BY-PRODUCT LEVELS TO A MAXIMUM OF 5PPM OF CARBON MONOXIDE (CO), AND 0.5PPM OF NITROGEN DIOXIDE (NO22ORECT FIRED UNITS SHALL BE CONFIGURED WITH THE BLOWER MOUNTED DOWNSTREAM OF THE BURNER. THIS ARRANGEMENT WILL ENSURE A CONSISTENT AIRFLOW, REGARDLESS OF INLET AIR TEMPERATURE. APPLICATION. SPRING -LOADED BURNER PROFILE PLATES ARE ENGINEERED TO AUTOMATICALLY REACT TO THE MOMENTUM OF A FRESH AIR STREAM, WITHOUT THE NEED FOR ANY MOTORS OR ACTUATORS TO MECHANICALLY ADJUST THEM. WITH THIS FEATURE, ALL DF UNITS ARE DESIGNED FOR DEMAND CONTROL VENTILATION (DCV) REQUIREMENTS. CERTIFICATIONS. ALL PROFILE PLATE ASSEMBLIES SHALL BE INCLUDED IN THE DF UNIT'S ETL LISTING AND COMPLY WITH COMBINED SAFETY STANDARDS ANSI Z83.4 AND CSA 3.7 (NON -RECIRCULATING OF HEATERS) AND ANSI Z83.18 (RECIRCULATING DF HEATERS), .FN RAIF CONSTRUCTION, -PROFILE PLATES SHALL BE FORMED FROM G90 GALVANIZED STEEL. -PROFILE PLATES SHALL VARY IN SIZE PER UNIT. -PROFILE PLATES SHALL BE MOUNTED ALONG THE SAME PLANE AS THE DISCHARGE [IF THE BURNER. -DESIGN SHALL INCORPORATE PROPERLY TORQUED, PERMANENTLY MOUNTED SPRING HINGES. -SPRING HINGES SHALL BE MADE FROM PLATED STEEL. RESUB Jul 15 2024 CITY OFEDMONDS ® GREASE DUCT & CHIMNEY SPECIFICATI❑NS1 PR❑VIDE GREASE DUCT EQUAL TO EC❑N-AIR MODEL "EDW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK, MODEL "EDW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP L❑CKING C❑NNECTI❑NS SEALED WITH 3M FIRE BARRIER 2000 PLUS, MODEL "EDW" DOES NOT REQUIRE WELDING PR❑VIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATI❑N GUIDE. PR❑VIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTI❑N AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "EDW" H❑RIZ❑NTAL RUNS LESS THAN 75 FT, CAN BE SLOPED 1/16" PER 12", H❑RIZ❑NTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12", DUCT SHOULD BE SLOPED AS MUCH AS P❑SSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATI❑N IN H❑RIZ❑NTAL RUNS, IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF C❑MBUSTIBLE MATERIAL, PR❑VIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO EC❑N-AIR MODEL "EDW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED ❑ APPROVED WTTN NO EXCEPTION TAKEN ❑ REVISE AND RESUBMIT ❑ SIGNATURE YOUR TIRE DATE RESUB Jul 15 2024 GREAS, DO COVE GRE F any. 3 ( GREASE BOX INSTALLATION ri ncED POSITION FAN. HINGE KIT (OPTIC IRB. POSITION PEVA2 OB/19/02 PARTS INCLUDED GREASE BOX. GREASE BOX COVER, GREASE PIPE. GREASE BOX FIELD INSTALLATION SHEET METAL SCREWS 3 - LONG (3/4' LG.). STEP 1 ATTACH GREASE BOX COVER TO THE CURB, HOLD 3' DIMENSION AS SHOWN ❑N PIC. 1. SCREW GREASE BOX COVER TO CURB USING (3) LONG (3/4' LG.) SCREWS AS SHOWN ON PIC. 2. / --- - CURB. PIC. 1 PIC. 2 T3' I CURB. GREASE BOX GREASE COVER. BOX STEP 2 COVER. ATTACH GREASE BOX TO GREASE BOX COVER, SLIDE AND DROP. AS SHOWN ON PIC. 3. , CURB. PIC. 3 GREASE BOX. GREASE BOX COVER. STEP 3 ---_V PIC. 4 INSTALL GREASE PIPE AS SHOWN ON PIC. 4. GREASE PIPE. RESUB Jul 15 2024 Ci*v oc Eom— Exhaust Fan Wiring JOB 6899152 - Gyro Makers Edmonds R2 DRAWING NUMBER EXH6899152-1 SHIP DATE 71312024 MODEL EADU85H Installed Options PWM 2 MOTOR ORRD_ _ _ _ _ _- RD CONTROL YW FROM oBK — — — — —� ECPM03 Component IdentlFication 3 rkK Label Description Location �H --- i 0 WH MT-01 o4 L--J WH R 4 SW-01 *22 AWG WHITE ROTATION WIRE - MT-01 Fan Motor 131 o—GR _ BMN MOTOR ONLY. CONNECT TO POWER WH WH LEG BLACK WIRE TO REVERSE ROTATION JUMPER WIRE DISCONNECTED. 5 TO REVERSE ROTATION CONNECT JUMPER FOR SW-01 Maln dlsconnect swltch 131 CKEC MOTOR ONLY. 6 7 8 9 10 11 12 13 14 15 MOTOR INF❑ 16 EXHAUST 1.OHP-115V-1P-11.6FLA 17 18 L CTR CALINFORMATION MOTOR C RL MCAT 14.SA MOTOR/CTRL MOPi 25A 19 20 NOTES DENOTES FIELD WIRING 21 DENOTES INTERNAL WIRING m WIRE COLOR 22 HPo Ill BK - BLACK YW - YELLOW =m ° cn BL - BLUE GR - GREEN Apo N C BR - BROWN GY - GRAY 23 a W OR - OR' -,E PR - PURPLE RD - RED PK - PINK WH - WHITE NOTES ■ = S4 and S6 1 nay be needed for NFBUP-S. L 3 4 J10 120V 7 8 W, " " RE -DV IEL/DELL.-A?<>61- IN an It18 in 16CV E DV-1 J33 m TOOHMI LOCAL HW C 0'w gp� Pi rq 987654321 RtyBL J361110 (40VATR-05 B' H N V -02 BL VA-01 Mo®987654321 1110 J7 a )eeeeee eeeeeeee eeeeeeee J12LDI-I—L—AI-1 J14LAI-2 1 AI-3 J28LDI-2 1 AI-4J BP 7654321 11109 8 J13 m BC U U L� (L d VA-0 ~ BL 987654321 7 1110 J32 TP1(FSC-llt- 7654321 1110 981 J18 MODBUS J16 LABELncmotorrnu J38 m06 R a Tam cmm r-BrAKO m BL-24VAC GY-INTLK e 0 EVaA!*4CU+SU-W F- Q e FSC-0I FWEYE_FLN@_SAFEIY 1101 Q 8 e G RT-m SIFPLY_MT R Y e MT-W IMfAKLDNP UTR W 0 m0 L e SN- I 0 DTTAKE Pti01 O e F Yn 0 RE -DV IICV_RELAY i e 0:::ce) SN-04 = F DISCH/IDGFL S**XX TTP_SOLSW I4/I m sw-m coom--rnfa 10 J15 p IT RESUB 0 e Jul 15 2024 ~ 0 of Es �N-, o"'IENT EN, w e F 0 TR-ae IATaTmx_T¢AruFTW TR-m Xm-.pWW OLTW LO e J35 VA-0T P1LOT-OAS VALVE vA-0t HAW-W-VALVE v:z HM-WVALVE LEGEND --FE3D vums - FACTORY Vdmri nJ 1K- LAOC YV- YELOW L- LIE ef- m BR- Rd M PR- RFBLE I 0- fa GAF m1 fat- GUN W/L- W/L SWE MOTOR INFO SUPPLY 1.5HP-23OV-3P-4.OFLA a.Aa)- RAW SOW VFD PARTi ESVI12NOISXB571 ! }.. -- MUA BOARD (DETAILS T❑ FOLLOW) MOTOR ��TION JOB NO DR CONTROL C RRCIRCUIT M MMCA, pp2.OA SYROLICIRCLITOMOP515A Installation Wiring JOB 6899152 - Gyro Makers Edmonds R2 DRAWING NUMBER RP6899152-2 SHIP DATE 71312024 MODEL EA1-D.250-15D 120 V 1 PH. 240 V 1 PH. 208/460/600 V 3 PH. Instatted Options Disconnect Disconnect Disconnect Switch Gal -flex conduit Switch Gal -flex conduit Switch Gal -flex conduit (in unit) � (In unit) � (In unit) Factory Factory Factory wiring wlring wiring Field Wired Switch ® ®rGR",us BK WHupplied Customer BK (RD supplied ®(GR ®®Ctomer Customer B B B R WH GR supplied wiring wiring wlring STANDING POWER RD & WH Wire (115V, 1 PHASE) OPTIONAL FOLLOW FAN SCHEMATICS Power Connection See above details, ............. FIELD WIRED CONTACTS SFMEIK---- WHEN USED WITH PREWIRE s,,Mr)L--� WIRE TO SFC1/SFO1 TO D3&D7 DAMPER INTERLOCK D30YW — — — WIRE TO ILIA & IL1B D70-o-D ---- NOTES nl Vi moo C V a W WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY PR - PURPLE RD - RED WH - WHITE ELECTRICAL PACKAGE — JOB"899152 NO TAG PACKAGE S LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 HP VOLT FLA 1 DCV-1111 WALL MOUNT IN SS HOX SS WALL MOUNT BOX I LIGHT 1 FAN SMART CONTROLS DCV EXHAUST 1 1.000 115 11.6 SUPPLY1 3 11.5001230 4.0 DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS, - CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM TURNDOWN REQUIREMENTS ❑UTLINED IN IECC 403.7.5 (2021). - THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL OR PAINTED STEEL. - TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISERS) SHALL BE CONSTRUCTED OF STAINLESS STEEL. - A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. - A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST SYSTEM IS REDUCED. - A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN CYCLING. - VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON DEMAND. THE DUCT TEMPERATURE SENSOR INPUTS) TO THE DIGITAL CONTROLLER SHALL BE USED TO CALCULATE THE SPEED REFERENCE SIGNAL. - THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS. - AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. - THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. - A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION IS DETECTED ON A COVERED HOOD. - A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL HMS FAN CONTROL VIA DRY CONTACT (EXTERNAL CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). - AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES, A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. E. MIS -WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. Duci / / ROON TENPERATU SENSOR SEQUENCE OF ❑PERATIONS, THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY GIVEN TIMEi - AUTOMATICi THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE, IF THE PANEL IS EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS 'DYNAMIC', THESE WILL MODULATE WITHIN A USER -DEFINED RANGE BASED ❑N THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS 'STATIC', FANS WILL RUN AT A SET SPEED CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). - MANUALi THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. - SCHEDULEiA WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. - OTHERi THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, HMS OR HARD -WIRED INTERLOCK). - FIRE, UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. RESUB Jul 15 2024 MODEL NUMBER DRAe+BY �AneTff DESCRIPTI❑N OF OPERATI❑NI 6899152 DCV-1111 INSTALL Demand Control Ventllatlon, w/ control for I Exhaust Fan, 1 Supply Fan, Exhaust on In Fire, Lights out In Fire, Fans modulate based n duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature JOB NAMF DATE DWG NO nsor shipped loose for field InstaU.M.n.Verlfy distance between VFD and Motorl additional cost could apply If Gyro Makers Edmonds R2 7/3/2024 ECP #1-1 alstan�e ex�eeas so feet. 1 2 24VAO----- SHUN COIL FAN START HOT TO SHUNT COIL BREAKER PANEL TO PRIMARY CONTROL PANEL 2,VpD--------- cDNTRQL PANEL------ — SIGNAL SFCl - - - - UI1E NEUTRAL FROM SHUNT COIL - - - - - SIGNAL FOR _ _ __-- 3 Responsibility, Electrician TO MUA BOARD NWIRE TO UNII EXTERNAL ST TERMINAL IS ENERGIZED BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED SUP-2 INTERLOCK SHUNT TRIP IN FIRE CONDITION. BREAKER PANEL PRIMARY CONTROL PANEL ONTAC R_COI REMOVE JUMPER HOT_TO_CONTACTOR_COIL 4 ______ Hot MAKE UP AIR ON PCB MUA ZONE 1 CONTROL PANEL $-------------- - - - - - - - - - - - - SIGNAL FOR NEUTRAL_TO_CONTACTOR_COIL - - - - - BREAKER 1PH Neutr H1 DAMPER - � � - - - - - - - - - - °l-- N1 120 V _ _ _ _ _ _ _ _ _ _ _ _ _ _ Ground PROVING - � EXTERNAL KS TERMINAL IS DE -ENERGIZED 5 15 A CONTROL POWER. DD NDT WIRE INTERLOCK LOW VOLTAGE CONNECTION FOR TERMINAL NAM S CONTACTOR COIL IN FIRE CONDITION. TO GFCI OR SHUNT TRIP DAMPER INTERLOCK. WIRE IF DO BYAOTHERS BREAKER. MULTIPLE SUPPLY ON THE SAME ZONE IN SERIES. SHOULD 5 1ST HOOD LIGHT BREAKER SHARED W/ HAVE CONTINUITY WHEN DAMPER CONTROL PANEL SFC1 _ _ _ _ _ _ _ COMMON CONTROL POWER. SWITCH #1 IS PROVEN OPEN. NORMALLY OPEN NOT REQUIRED FOR ALL UNITS. DRY CONTACT - - - - - - - - - BREAKER 1PH - - - - - - - - - - - - - - - -Hot - L1 SEE MAKE-UP AIR SCHEMATIC. ON/OFF WITH COMMON - 7 120 V Neu'LmL_— SFC2------------- Ground - SUPPLY FAN _ _ _ _ _ _ NORMALLY OPEN - — — — — — — — — — — — — — — — GND GROUP 1 SPARE CONTACTS WILL MAKE MCAT 25.0 A COMMON TO NORMALLY OPEN B MOCP, 30 A WIRE PTO VFD QUICK S CONNECTOR WHEN SUPPLY FAN IS ON. CONTROL PANEL TO ACCESSORY ITEMS 9 Responsibility, Electrician DCV SPEED — — — — — — — — — — — — — — -- TO BMS CONTROL PANEL COMPONENT 0-I0V OUTPUT B W ON PCB IRE TO ECPM03 TERMINALS CONFIGURABLE OUTPUT. 10 BREAKER PANEL TO FANS MICROSWITCH 1 (TOTAL) SEE ECPM03 OWNERS MANUAL. Responsibility, Electrician CONTROL PANEL 41NO VFD ANALOG 30 + BREAKER PANEL FANS TO Lma = TO BMS SI�INC , 0-10V OUTPUT 2 - - - - - - - - - - - - - - -------------- 11 FIRE SYSTEM J IN VFD WIRE TO VFD TERMINAL STRIP. MICROSWITCH WIRE C1 TD COMMON (1), _ _ _ _ - - - - PROPORTIONAL TO FREQUENCY. -HOT - _ WIRE ARI TO NORMALLY CLOSED (2). (EACH VFD) SEE VFD OWNERS MANUAL. BREAKER 1PH _ NEUTRAL - _POWER TO CI TO ARI SHOULD HAVE MS-1 CAP HMS SWITCH 12 115V Ground - _ECM FANS CONTINUITY WHEN ARMED. 1 4iN�DFF CONTROL PANEL - - - - - - - - - - - - - - - �,NO ------- MCA, 14.5A EXH-1---------------7 TO - - - - - - - - - - - - - - ----J MOCP, 25A IF MORE THAN ONE r - - - J SIGNAL SWITCH THROUGH BMS 13 FIRE SYSTEM, WIRE MS-2 41NO OFF EXTERNAL WILL ACTIVATE ZONEI FANS AND IN SERIES AS SHOWN L - 1,C�%,NC, SWITCH LIGHTS 14 CONTROL PANEL TO FANS CONTROL PANEL ALL SWITCHES FACTORY WIRED 15 Responsibility, Electrlclan TO J4 CAT-5 CONNECTION PRIMARY PANEL FANS SWITCHES 15 FEED STP THROUGH INNER RD TO RD HOOD LIGHTS NIDEC MOTOR _ _ _ _ _ _ _ _ _ _ _ _ COOLING TUBE. ALLOW FOR CONTROL PANEL BLACK PWM ENOUGH SLACK ON STP FOR Bl< MOTOR TO - - - - - - - - - - - WHITE - - 17 SPEED SIGNAL PROPER HINGING. (EXHAUST ONLY) BK TO MO _ _ _ _ - GREEN _ _ - - J SENSITIVE. 1400 W MAX ECM-01 NOTE, PWM SIGNAL IS POLARITY ZIEHL MOTOR BK TO BK HOOD LIGHTS WIRE TO J-BOX ON TOP OF HOOD CONTROL OUTDOOR RATED 18 SHIELDED TWISTED PAIR EXH-1 PANEL TO EIKZ REDaI , CONTROL PANEL T1A - - - - - - - - - - - - - - - -T ECM ucy5_ B�acKT-1A - ECM_OJ TO T1B WIRE TO CONTROL BOARD. INSTALL - J 19 FANS 01 ROOM TEMP SENSOR IN ROOM AWAY FROM HEAT ROOM TEMP SENSOR SOURCES. DO NOT INSTALL SENSOR GROUPS, FAN. 02 SUP-2 FLaM.o ON THE CEILING GRID, SEE MANUAL. 20 Load Wlring Ul --L°A° LEG 1-- - A. o HW Ism SM-1 1 — LDAD LEG 2— — — BLACK O VOLT.I20 V — — — — — — — — — — — — — — — WIRE TO - L°-A° �W 3-- - BLAB ° CONTROL PANEL T2A -- 120V HOT-- RED TO T2B WIRE TD CONTROL BOARD. SHIP LOOSE RESUB 21 VFD QUICK - - - ° DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT DUCT STAT Jul 15 2024 CONNECTOR ->2ov NEUTRAL- - - A WHITE - - GROUND- - A GREEN DE CITY OF EDMONDS VELOPMENT Es DEPARTMENT 22 IF VFD MOUNTED THE FOLLOWING CONNECTIONS IN 2ND PANEL, MUST HAVE ITS OWN CONDUIT MAY OR MAY NOT BE WIRE SF SIGNAL DO NOT SHARE CONDUITI REQUIRED BASED ON JOBSITE FROM PANEL WITH SPECIFICATIONS 23 ECPM03. 24 UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. 1 J9 120V 1 WH — — CONTROL INPUT 120V I + HK __ H1=1-INE, N1=NEUTRAL, HK 15A BREAKER. D❑ NOT GAS — — CONNECT TO SHUNT TRIPRis = ® BK BREAKER. SEE 3 + 24V 2 BK - - INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. PS-01 DC TERMINAL GAS USED FOR y N LAC 120V POWERED GAS H1 BK -- VALVES ONLY z� PANEL LID I G �-- L3 3 4 J7 120V 1 BK BK 14AWG R 1 I�aHI BK WH Jr 3 BK HOOD GHTS I,- JUMPER "NI BK 6 DC+ B�® RD-1 7 PR RO1 7 MAKE UP AIR INTERLOCK. JUMP R �J10 J10 ECPM03 ECPM03 9 SE 24 AR1C JUMPER FIRE SYSTEM ^Hl NOTE, All Items on ECPM03 J3 line to be daisy chalned from one component to the next, with EOL120A at end of line. Pace PN1 EOL120A In empty RJ45 port. ECPM03/DAISY CHAIN - FACTORY WIRING SCHEMATIC NOTE, IF VFD HAS IPH 240V INPUT, USE LI & L2 ONLY. CIRCUIT BOARDS 20 IF VFD HAS 1PH 1V INPUT, USE L1 & N ONLY. ECPM03 67.8% 84.77 I I I I I I I I e0 DRY CONTACTS (SHOWN DE -ENERGIZED) 14 AWG RA-1-1 - �— WrfOH FF C YW ME 14 AWG RA-2-1 ON/OFF _ NO WITH C YW SUP 14 AWG RA-2-2 NO� C YW RA-x RD-X 120 VAC 24 VDC RELAY RELAY NO 4 3 NO 4 3 NC 2 1 NC 2 1 COIL 8 7 COIL 8 7 COM 6 5 COM 6 5 ST-X Stcrteer PN OL-X Overload PNi —1- C-X CORt-tor PN v 11-1 Power eIup241D:: PNi MDP18-24A-IC RA-x 120V Relayy BRIT PN: 34.110.01840 RD-x 24VDC Ligqht Relay PN� 34.110.0108,0 RESUB Jul 15 2024 CRY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT — E ULL U W1KliNU FACTORY WIRIND BK- BLACK YW- YELLUW EL- BLUE GY- GREY BR- BRUWN PR- PURPLE OR- ORANGE RD- RED WILT WHITE OR/BL- OR/BL STRIPE BL/RD- EL/RD STRIPE RE/TNT RD/GN STRIPE WH/BL- WH/BL STRIPE Demand Control Ventllatlon, w/ control for 1 Exhaust Fan, I Supply Fan, Exhaust on In Fire, Lights out In Fire, Fans modulate based on duct temperature, INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field Instnllntlon.Verlfy distance between VFD and MoMrI additional cost could apply If distance exceeds 50 A I B I C D E F G H I FACTORY WIRING MOTOR POWER CIRCUITS. SEE INSTALLATI❑N SCHEMATIC DIAGRAM FOR FIELD WIRING REQUIREMENTS. CIRCUIT BOARDS ECPM03 MTi 10 AWG FLA:4.0 DCV Rev, 2.10.00 1 PHP]VRRHO BK U/TP00.0100HMI Rev, 2,10.00 120 VBK V/T2 P10LN/A RA-x RD-x 30 At/T3 P102�0.0 120 VACP303)72.1RELAY P107101 P131iWA/N NO NCNC RELAY NO 4 3P10&66 2 1 P150101 P16T72,1 COIL 8 7 COM 6 5 COIL 8 7 COM 6 5 VFD1ESVI12N01SXB571 P194:225 10 P410 21 COMPONENT LIST LABEL DESCRIPTION F�. C-X Contactor —Ies v es SM-X VF➢ Pi varies LR-X Line/Load Re-t- PIN1 varies RESUB Jul 15 2024 el OF EDMONDS DEVELOPMENT SERVICES LEGEND ---FIELD WIRING FACTORY WIRING BK- BLACK YW- YELLU, BE- BLUE GY- GREY BR- DROWN PR- PURPLE OR- ORANGE RD- RED WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/OJ STRIPE WH/BL- WH/BL STRIPE JOB NAME G ro Makers Edrlo,„ DRAINING TITLE DCV-I111 DESCRIPTION OF OPERATION Denand Control Ventl,at" �/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on In Flre, Lights out In Fire, Fans nodulate based on duct tenperature�INVERTER DUTY 3 PHASE MDTOR REQUIRED FDR USE WITH VFD. Roon tenperature sen— shipped loose for field Installation.Verify distance beteeen VFD and Motor) additional t could appl If distance ex 50 fleet. JOB NO DRAWN BY TYPE DATE SC-20 x 18 x 8,62 BOX/ OWG NOECP #1-3 oo