REV1 REVIEWED BLD RESUB1 BLD2021-0809+Structural_Calculations+9.11.2024_1.55.46_PM+4494361ESGDESIGN Ell Grassley,PF
REVISION..............................................�
REVIEWED
RESUB BY
Sep 11 2024 BLD2021-0809 CITY OF EDMONDS
BUILDING DEPARTMENT
CITYOF EDMONDS;...............................................
DEVELOPMENT SERVICES
DEPARTMENT
5TRUCTURAL CALCULATION5
FOR
EDMONDS HOMES -UNIT 2
FRAMING REY1510N5
Edmonds, kYA
PREPARED BY:
E5G 0f51GN, PLLO
J une 10 , ZOZ4
ENGINEERED • STRUCTURES • GLOBAL • DESIGN
6-10-2024
/ WAS/1�,y�\.
<,e,o,
I
�„ ;�- '
AL 0
ESG Design, PLLC - 12540 202nd PL SE, Issaquah, WA 98027 1 engineer@esg-design.com 1 206-660-2044
ESGDESIGN
GRAVITY DESIGN
Eli Grassley, P.E.
ENGINEERED • STRUCTURES • GLOBAL • DESIGN I Edmonds Homes
E S G D E S I G N Eli Grassley, P.E.
ROOF FRAMING SCHIEME
ENGINEERED STRUCTURES GLOBAL DESIGN Edmonds Homes
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, Roof Rafter
1 piece(s) 11 7/8" THO 360 @ 24" OC
PASSED
- +
0 � 0
r
IL �
l
1
22 i
C
9
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
931 @ 2 1/2"
1731 (3.50")
Passed (54%)
1.15
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
908 @ 3 1/2"
1961
Passed (46%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
5220 @ 11' 7 1/2"
7107
Passed (73%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.793 @ 11' 7 1/2"
1.146
Passed (L/347)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1.271 @ 11' 7 1/2"
1.527
Passed (L/216)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Beveled Plate - SPF
3.50"
3.50"
1.75"
350
581
931
Blocking
2 - Beveled Plate - SPF
3.50"
3.50"
1.75"
350
581
931
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' o/c
Bottom Edge (Lu)
23' 4" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
-Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions.
Vertical Load
Location
Spacing
Dead
(0.90)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 23' 3"
24"
15.0
25.0
Roof
Member Length : 23' 4 15/16"
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Member Pitch : 1/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:12:35 PM UTC
ForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Vkyerhacuser File Name: Edmonds A Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, Roof Beam B1
1 piece(s) 3 1/2" x 12" 24F-V4 DF Glulam
PASSED
- +
I. 12 I.
C
2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5349 @ 2"
7963 (3.50")
Passed (67%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
4251 @ 1' 3 1/2"
8533
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
15948 @ 6' 3 1/2"
19320
Passed (83%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.293 @ 6' 3 1/2"
0.408
Passed (L/501)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.475 @ 6' 3 1/2"
0.613
Passed (L/310)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: ILL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 12' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column - SPF
3.50"
3.50"
2.35"
2046
3303
5349
Blocking
2 - Column - SPF
3.50"
3.50"
2.35"
2046
3303
5349
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' 7" o/c
Bottom Edge (Lu)
12' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 12' 7"
N/A
10.2
1 - Uniform (PSF)
0 to 12' 7" (Front)
21'
15.0
25.0
Roof
• Side loads are assumed to not induce cross -grain tension.
Member Length : 12' 7"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:18:22 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
VA- erhacuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT PASSED
Unit 2 Roof, B1 Post
1 piece(s) 4 x 6 HF No.2
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
27
50
Passed (55%)
Compression (Ibs)
5349
9143
Passed (59%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
5349
8181
Passed (65%)
--
1.0 D + 1.0 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
3080
Passed (2%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
2558
Passed (5%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.06 @ mid -span
0.86
Passed (L/1703)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.66
1
Passed (66%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
2046
3303
B1
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:38:16 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, Roof Beam B2
1 piece(s) 5 1/2" x 12" 24F-V4 DF Glulam
PASSED
. - 1:-.11 _- - -: 7 1 4
- +
0
149" I.
C
2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6563 @ 2"
12513 (3.50")
Passed (52%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5457 @ 1' 3 1/2"
13409
Passed (41%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
24076 @ 7' 8"
30360
Passed (79%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.419 @ 7' 8"
0.500
Passed (L/429)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.684 @ 7' 8"
0.750
Passed (L/263)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: ILL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 15'.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column - SPF
3.50"
3.50"
1.84"
2538
4025
6563
Blocking
2 - Column - SPF
3.50"
3.50"
1.84"
2538
4025
6563
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
15' 4" o/c
Bottom Edge (Lu)
15' 4" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary
(0.90)
(1.15)Width
Comments
0 - Self Weight (PLF)
0 to 15' 4"
N/A
16.0
1 - Uniform (PSF)
0 to 15' 4" (Front)
21'
15.0
25.0
Roof
• Side loads are assumed to not induce cross -grain tension.
Member Length : 15' 4"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:46:07 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
VA- erhacuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, B2 Post
1 piece(s) 4 x 6 HF No.2
PASSED
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
27
50
Passed (55%)
Compression (Ibs)
6563
9143
Passed (72%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
6563
8181
Passed (80%)
1.0 D + 1.0 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
3080
Passed (2%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
2558
Passed (5%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.07 @ mid -span
0.86
Passed (L/1456)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.94
1
Passed (94%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Drawing is Conceptual Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
2538
4025
62
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:49:46 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, Roof Beam B3
1 piece(s) 5 1/2" x 12" 24F-V4 DF Glulam
PASSED
C
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5743 @ 2"
12513 (3.50")
Passed (46%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
4637 @ 1' 3 1/2"
13409
Passed (35%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
18316 @ 6' 8 1/2"
30360
Passed (60%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.243 @ 6' 8 1/2"
0.436
Passed (L/647)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.396 @ 6' 8 1/2"
0.654
Passed (L/397)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: ILL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 13' 1".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column - SPF
3.50"
3.50"
1.61"
2221
3522
5743
Blocking
2 - Column - SPF
3.50"
3.50"
1.61"
2221
3522
5743
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 5" o/c
Bottom Edge (Lu)
13' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 13' 5"
N/A
16.0
1 - Uniform (PSF)
0 to 13' 5" (Front)
21'
15.0
25.0
Roof
• Side loads are assumed to not induce cross -grain tension.
Member Length : 13' 5"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:51:57 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
VA- erhacuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Roof, 82-83 Post
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
18
50
Passed (37%)
Compression (Ibs)
12306
52037
Passed (24%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
12306
17227
Passed (71%)
1.0 D + 1.0 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
8812
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.06 @ mid -span
0.86
Passed (L/1594)
1.0 D + 1.0 S
Bending/Compression
0.23
1
Passed (23%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Drawing is Conceptual Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
2538
4025
B2
2 - Point (lb)
N/A
2221
3522
B3
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/8/2024 5:14:30 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
IFORTEWEB
MEMBER REPORT
Unit 2 Roof, Header H1
2 piece(s) 2 x 8 HF No.2
PASSED
0
Overall Length: 6' 3"
1 � I
E❑
❑2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1267 @ 0
1823 (1.50")
Passed (70%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
972 @ 8 3/4"
2501
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1980 @ 3' 1 1/2"
2569
Passed (77%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.069 @ 3' 1 1/2"
0.208
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.112 @ 3' 1 1/2"
0.313
Passed (L/667)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories IF
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
486
781
1267
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
486
781
1267
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 3" o/c
Bottom Edge (Lu)
6' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 6' 3"
N/A
5.5
1 - Uniform (PSF)
0 to 6' 3"
10'
15.0
25.0
Roof
0
Member Length : 63"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 9:15:01 PM UTC
!- ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
AWW 3ik
File Name: Edmonds x4 Units
Page 1 / 1
.1FORTEWEB
MEMBER REPORT
Unit 2 Roof, Header H2
1 piece(s) 6 x 10 HF No.2
PASSED
C
L
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7915 @ 3"
10024 (4.50")
Passed (79%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1199 @ 1' 2"
5608
Passed (21%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3643 @ 1' 4 1/2"
5352
Passed (68%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.005 @ 1' 4 1/2"
0.075
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.008 @ 1' 4 1/2"
0.112
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - HF
4.50"
4.50"
3.55"
3072
4843
7915
None
2 - Trimmer - HF
4.50"
4.50"
3.55"
3072
4843
7915
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
2' 9" o/c
Bottom Edge (Lu)
2' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 2' 9"
N/A
13.2
1 - Uniform (PSF)
0 to 2' 9"
1'
2221.0
3522.0
Beam B3
0
Member Length : 2' 9"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 10:02:35 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Wayahac.,,_. File Name: Edmonds x4 Units
Page 1 / 1
IFORTEWEB
MEMBER REPORT
Unit 2 Roof, Header H3
2 piece(s) 2 x 8 HF No.2
PASSED
0
Overall Length: 6' 3"
1 � I
E❑
❑2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1517 @ 0
1823 (1.50")
Passed (83%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1163 @ 8 3/4"
2501
Passed (47%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2371 @ 3' 1 1/2"
2569
Passed (92%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.083 @ 3' 1 1/2"
0.208
Passed (L/902)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.135 @ 3' 1 1/2"
0.313
Passed (L/557)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories IF
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
580
938
1517
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
580
938
1517
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 3" o/c
Bottom Edge (Lu)
6' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 6' 3"
N/A
5.5
1 - Uniform (PSF)
0 to 6' 3"
12'
15.0
25.0
Roof
0
Member Length : 63"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 10:05:39 PM UTC
!- ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
AWW 3ik
File Name: Edmonds x4 Units
Page 1 / 1
IFORTEWEB
MEMBER REPORT
Unit 2 Roof, Header H4
1 piece(s) 4 x 10 HF No.2
PASSED
0
in
9'
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2129 @ 1 1/2"
4253 (3.00")
Passed (50%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1671 @ 1' 1/4"
3723
Passed (45%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
4794 @ 4' 9"
4879
Passed (98%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.151 @ 4' 9"
0.308
Passed (L/735)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.246 @ 4' 9"
0.463
Passed (L/451)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories IF
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
3.00"
3.00"
1.50"
823
1306
2129
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
823
1306
2129
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3" o/c
Bottom Edge (Lu)
9' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 9' 6"
N/A
8.2
1 - Uniform (PSF)
0 to 9' 6"
11'
15.0
25.0
Roof
0
Member Length : 9' 6"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 10:06:58 PM UTC
!- ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
AWW 3ik
File Name: Edmonds x4 Units
Page 1 / 1
E S G D E S I G N Eli Grassley, P.E.
UPPER FLOOR FRAMING SCHEME
r
w/12 RIZGO SCREZH
NAIL @ 4/12 PATTERN
2'_0" 14 21'_6"
42'-0"
ENGINEERED STRUCTURES GLOBAL DESIGN Edmonds Homes
.I F0 RT E W E B MEMBER REPORT
Unit 2 Upper Level, Upper Floor Joists
1 piece(s) 11 7/8" TJI@ 360 @ 16" OC
PASSED
r:-. 11 _ r -: T - 1
1 +
G 0
2' 21' 6"
o a
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
762 @ 23' 10 1/2"
1202 (2.25")
Passed (63%)
1.00
1.0 D + 1.0 L (Alt Spans)
Shear (Ibs)
970 @ 2'
1961
Passed (49%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3883 @ 13' 7"
6180
Passed (63%)
1.00
1.0 D + 1.0 L (Alt Spans)
Live Load Defl. (in)
0.595 @ 13' 1/8"
0.724
Passed (L/438)
1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)
0.725 @ 13' 2 11/16"
1.086
Passed (L/360)
1.0 D + 1.0 L (Alt Spans)
TJ-Pro"" Rating
27
25
Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Stud wall - SPF
3.50"
3.50"
3.50"
707
700
577
1665
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1.75"
179
591
-52
770
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals
Comments
Top Edge (Lu) 4' 8" o/c
Bottom Edge (Lu) 6' 8" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 24' 1"
16"
15.0
40.0
-
Upper Floor
2 - Point (lb)
0
N/A
405
-
525
Roof
Member Length : 23' 11 3/4"
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 11:31:12 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds 0 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT PASSED
Unit 2 Upper Level, Beam B4
1 piece(s) 4 x 12 HF No.2
0 0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2167 @ 2"
4961 (3.50")
Passed (44%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1546 @ 1' 2 3/4"
3938
Passed (39%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
4296 @ 4' 3 1/2"
5752
Passed (75%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.070 @ 4' 3 1/2"
0.275
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.097 @ 4' 3 1/2"
0.412
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
3.50"
1.53"
622
1545
2167
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1.53"
622
1545
2167
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 7" o/c
Bottom Edge (Lu)
8' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
0 to 8' 7"
N/A
10.0
1 - Uniform (PSF)
0 to 8' 7" (Front)
9'
15.0
40.0
Upper Floor
• Side loads are assumed to not induce cross -grain tension.
Member Length : 8' 7"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/8/2024 11:49:11 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
VA- erhacuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Upper Level, 84 Post
1 piece(s) 3 1/2" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
27
50
Passed (55%)
Compression (Ibs)
8730
17320
Passed (50%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
8730
11484
Passed (76%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
4508
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment (ft-Ibs)
140 @ mid -span
5753
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.07 @ mid -span
0.86
Passed (L/1447)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.48
1
Passed (48%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Drawing is Conceptual Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : Aso
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Point (lb)
N/A
622
1545
B4
2 - Point (lb)
N/A
2538
4025
B2
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
POST FOUNDATION CALCULATIONS:
ASSUMED SOIL BEARNG CAPACITY- 1,500 PSF
MIN. FOUNDATION AF'EA:
(622# + 2538# + 1545# + 4025#) / 1,500 PSF = 5.8 SF
PROVIDE 30"x 30" FOUNDATION - 6.25 SF
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 10:47:16 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Upper Level, Beam B5
1 piece(s) 5 1/2" x 12" 24F-V4 DF Glulam
PASSED
C
1
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6067 @ 4"
9467 (4.25")
Passed (64%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
4854 @ 1' 5 1/2"
11660
Passed (42%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
19172 @ 6' 10 1/2"
26400
Passed (73%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.296 @ 6' 10 1/2"
0.327
Passed (L/530)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.414 @ 6' 10 1/2"
0.654
Passed (L/379)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: ILL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 13' 1".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - HF
5.50"
4.25"
2.72"
1759
4400
6159
1 1/4" Rim Board
2 - Stud wall - HF
5.50"
4.25"
2.72"
1759
4400
6159
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu) 13' 7" o/c
Bottom Edge (Lu) 13' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 13' 7 3/4"
N/A
16.0
1 - Uniform (PSF)
0 to 13' 9" (Front)
16'
15.0
40.0
Upper Floor
• Side loads are assumed to not induce cross -grain tension.
Member Length : 13' 6 1/2"
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/6/2024 10:53:56 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
VA- erhacuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RTE W E B MEMBER REPORT PASSED
Unit 2 Upper Level, 85 Post 1
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
18
50
Passed (37%)
Compression (Ibs)
15508
52037
Passed (30%)
1.15
1.0 D + 0.75 L + 0.75 S
Plate Bearing (Ibs)
15508
17227
Passed (90%)
--
1.0 D + 0.75 L + 0.75 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
8812
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.09 @ mid -span
0.86
Passed (L/1140)
--
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.34
1
Passed (34%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : Aso
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
1759
4440
-
135
2 - Point (lb)
N/A
2538
-
4025
B2
3 - Point (lb)
N/A
2221
3522
-
B3
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
POST FOUNDATION CALCULATIONS:
ASSUMED SOIL BEARING CAPACITY- 1,500 PSF
MIN. FOUNDATION ARE4
(1759# + 2538# + 2221 # + 4440# + 3522#) / 1,500 PSF = 9.65 SF
PROVIDE 4 2 " x 4 2 " FOUNDATION - 12.25 SF
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/8/2024 5:27:42 PM UTC
AForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.l FO RT E W E B MEMBER REPORT
Unit 2 Upper Level, 85 Post 2
1 piece(s) 3 1/2" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
27
50
Passed (55%)
Compression (Ibs)
11942
17320
Passed (69%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
11942
12311
Passed (97%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
4508
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment (ft-Ibs)
140 @ mid -span
5753
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.09 @ mid -span
0.86
Passed (L/1095)
1.0 D + 1.0 L
Bending/Compression
0.81
1
Passed (81%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
Supports
Type
Material
Top
Dbl 2X
StrandGuard@ LSL
Base
2X
StrandGuard@ LSL
Drawing is Conceptual Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : Aso
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Point (lb)
N/A
1759
4440
B5
2 - Point (lb)
N/A
2221
3522
B3
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/8/2024 11:31:56 PM UTC
AForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units