Loading...
APPROVED ENG PLN BLD RESUB 1-BLD2024-0896+Plan_Set+9.9.2024_1.19.06_PM+4488457= The following documentation shall be available on site for the building inspector: ■ 10 F1 COE APPROVED ARCHITECTURAL PLAN SET ' ■ 1 F.1 COE APPROVED STRUCTURAL PLAN SET 1 ' COE REVIEWED CALCULATION PACKET = ENERGY CREDIT WORKSHEET ' ❑ SITE PLAN ; ■ ❑ CIVIL PLAN 1771 Manufactures specs for retractable cover. ■ HOT TUB NOTES: 1. REFER TO HOT TUB SPECiFiCATiON DRAWINGS BY OTHERS 2.1260 GALLON HOT TUB 3. INSTALL PENTAIR MASTER TEMP NG 250,000 BTU GAS HEATER PER MANUFACTURER 4. INSTALL PENTAIR RAINBOW CHLORINE FEEDER PER MANUFACTURER. 5. HOT TUB TO BE FILLED ViA HOSE BiB OFF POTABLE WATER SUPPLY. 6. INSTALL AUTOMATIC HOT TUB COVER PER MANUFACTURER. 7. INSTALL REDUCED PRESSURE 13ACKFLOW PREVENTOR AT EQUIPMENT ROOM DOMESTIC WATER LiNE. 8. NO INTEGRATED DRAIN TO BE INSTALLED iN HOT TUB. CONTACT MANUF CTURER TO DRAIN HOT TUB ViA PUMP FOR MAINTENANCE. AND CITY OF EDMONDS 9. HOT TUB COVER BOX TO HAVE INTEGRATED DRAIN FOR MiNiMAL WATER COLLECTION (EST:1/4 GALLON PER OPENING) HOT TUB WATER DISPOSAL NOTES: 1. VERIFY THE FOLLOWING DISCHARGE CONDITIONS ARE MET: A. DISCHARGE CONTAINS LESS THAN 0.1 MILLIGRAM PER LITER OF TOTAL RESIDUAL CHLORINE B. DISCHARGE DOES NOT CONTAIN ALGiCiDES OTHER THAN CHLORINE OR BROMINE COMPOUNDS C. DISCHARGE 15 THERMALLY CONTROLLED AS NECESSARY TO PREVENT AN INCREASE iN TEMPERATURE OF RECEIVING WATERS 2. THE DISCHARGE OF SPA CLEANING WATER TO THE GROUND, SURFACE WATERS, OR THE STORM DRAINAGE SYSTEM 15 NOT ALLOWED. 3. FILTER 5ACKWA5H SHALL NOT BE DISCHARGED INTO THE SEWER SYSTEM. DISPOSE OF FILTER MATERIAL A5 SOLID WASTE. 4. DISCHARGE WATER SHALL BE CLEAR OF ANY COLORATION, DIRT, SUDS, ALGAE, OR FILTER MEDIA 5. SALTWATER SPA WATER MAY NOT BE DISCHARGED TO THE STORMWATER DRAINAGE SYSTEM. A PROFESSIONAL SERVICE 15 REQUIRED TO COLLECT ALL WATER FOR OFF -SITE DISPOSAL AT AN APPROVED LOCATION. 6. NO INTEGRATED DRAIN TO BE INSTALLED AT HOT TUB. COVERBOX DRAIN TO MEET CiTY OF EDMONDS REQUIREMENTS. HOT TUB OPERATIONAL NOTES: 1. CLEAN THE HOT TUB REGULARLY 2. MAINTAIN PROPER CHLORINE LEVELS, WATER FILTRATION, AND CIRCULATION. 3. MANAGE PH AND WATER HARDNESS TO REDUCE PiPE CORROSION THAT CAN STAIN THE FACILITY AND POLLUTE RECEIVING WATERS 4. DEVELOP AND REGULARLY UPDATE A FACILITY MAINTENANCE PLAN THAT FOLLOWS ALL DISCHARGE REQUIREMENTS 5. DISPOSE OF UNWANTED CHEMICALS PROPERLY. 6. STORE HOT TUB CHEMICALS UNDER COVER AND iN ENCLOSED CONTAINERS ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 APPROVED // /' /' /' `� HOT TUBS SHALL NOT DIRECTLY LAND USE CODE COMPLIANCE STATISTICS ZONE: KS-20 CRITICAL AREAS: LANDSLIDE AND EROSION HAZARD; WiLDLAND URBAN REQV SETBACKS: FRONT: 25' REAR SETBACK: 35'&10' SiPE SETBACK: 25' PARKiN�- 3 EXISTING GARAGE PARKING SPACES TO REMAIN BUILDING HEIGHT BUILDING HEIGHT LIMiT = 25' INFORMATION: REFER TO SHEET A2.0 AND A2.1 FOR DETAILED HEIGHT INFORMATION NO CHANGE PROPOSED EXISTING LOT AREA: LOT COVERAGE: EXISTING HOUSE & GARAGE: EXISTING DECK: EXISTING GAZEBO: EXISTING LOT COVERAGE: ALLOWED LOT COVERAGE: PROPOSED *NO CHANGE PROPOSED LOT COVERAGE: PROPOSED EXISTING HOUSE/ROOF: IMPERVIOUS EXISTING WALKWAYS & STAIRS: SURFACE: EXISTING DECK: CONNECT TO SEWER. WHEN / EXISTING PATIO (UPPER): DRAINING THE HOT TUB, / EXISTING PATIO (LOWER): / - . L • SS E,9S - - - _ I_ - EXISTING DRIVEWAY: / r - - - ENT. REC #1 412 - CONTACT THE CITY OF / // EXISTING IMPERVIOUS SURFACE: PLANS MUST BE- -- • - EDMONDS FOR REQUIREMENTS ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANC 75,358.8 5F (1.73 ACRES) 4,431.7 SF 1,571.1 SF 315 SF 6,317.8 5F (8.4%) 75,358.85F X 35% = 26,375.6 SF OK S / vJ w�1LL - -S _SASS -ti .-- - / f - SAS '-�- HOI ' ,, �, HO BDR - ----_S �• I PL RAI % � _ TO CO T TO - - � O ��, w � I - _ . 435.36' / o - EV M - - J o LU Q N 82°4245" - • _ . / HOt TUB LOCATION ,� EV - I W- �OWER FLOOR EX - S-----�----- �`' ' - • - . CO EKED PATIO EX WALKWAY I. ------------------ / (N DRP , EX DOG RUN56 , I I EX PATiO cn- ' / �2 EXISTING ATTACHED EX RET. WALL I c I ' F�X GARAGE , i I SEE HOT TUB I DECK 6o NOTES #7 I VC 56HE ' I 40 H0f TUB S LLJ / PLUMBING ' J � EX LOWER PATiO XLLI 70� LU / HOT TUB EQUIP. I I 1 02 TALB / I - 5S-EA ENT: REC #206949 /\ LOCATION @ ED PS, W _ _ \ LOWER FLOOR I TERiOR OBTAIN ELECTRICAL . ±- -- - - - I -------_ \STORAGE I i I LU \ , REF 1 I E PERMIT FROM ��cn I \ \ I , D2 2, LO STATE LABOR &�' Jo a I Z _ - _ EX GAZEBO \ \ / D. INDUSTRIES,' 25'-011 ' REQ'D REAR EX T I I / I I I I � I ' ROA EX DRIVEWAY 5020 cn / 25'-0,, 0 RE Q'D FRO T # M I YARD I I / I I I ►- ' EX PLANTER / / ICY?/ / I M �j 0 / I YARD \ 1 REr w�1LLLLI Q I m 0 J XLU i Q \ i o cn / i I \ X WAL + a� �>_ LU \ �X w - - - - - - - - - - - - - - - - \ - - - - - - - - - - - - - - - - -s S -s s s s S s s S S S S S s s - S ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE SITE PLAN MW M OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. SCALE: 1" = 20' NOTE: 1. SiTE PLAN PER CiTY OF EDMONDS GiS MAPPING 2. ALL UTILITIES TO BE LOCATED AND VERIFIED PRIOR TO ANY GROUND DISTURBANCE. 3. ALL EXISTING TREES TO REMAIN; PROVIDE TREE PROTECTION FOR ALL TREES WITHiN CONSTRUCTION SiTE AT DRiP LiNE OR GREATEST EXTENT POSSIBLE 4. REFER TO STRUCTURAL ENGINEERING DRAWINGS AND CALCULATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. AVERAGE EXISTING GRADE POINT ELEVATION A 86.5' B 90.0' C 92.0' D 82.0' 350.5F/4= 87.6' = 87-8" (ROUND TO NEAREST INCH) AVERAGE GRADE=87'-8" 25' HEIGHT LIMIT = 112'-8" EX DRIVEWAY S/ - - -Cn ' 120, LU - - 0 - - - - - - - - - - J Ln L - - - - - - - - ! � o Q 55 EASEMENT: REG #2127168 � ' i - - - - - - - - - - - - - � i c�1 b >-UJ - S S S S S S �- S S S S S S' S S S S S S s 55�1 Cz ._.J M M iv M �� M M M M M M M M i i Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. APPROVED BY PLANNING �40_ _ Oct 02 2024 Zone -- - -- Corner Flag Setbacks: Required Actual 25' Front --------- ok --------- 10735' : N36'8.5 . Sides '----------- 25 95' Rear Other -_ __ __ _ - Height : ------ ' Hot tub review only Building Department 5222.6 5F +/- 1868.1 SF +/- 1233.6 SF +/- 1146.9 SF +/- 2061.9 SF +/- 9576.8 SF +/- 21,110.1 SF +/- (25%) NO CHANGE PROPOSED Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED t" /k i! 10/ 11 /2024 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS Work HOT TUB -BELOW GRADE i............................... --•- ................................ .............................................................................................................. Address 17802 TALBOT RD ................................. ...............................................................• ,.................................................... Owner • COLE Approved Date' 09/23/2024 Building Official Permit Number BLD20 . 24-0896 W U z 0 � N LU 00 rn W 0 IJ N 0 Z O J r � O Lu U 9716 REGISTERED ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H I T E C T U R E + D E SI G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darc h i tects.c om DATE: 4/10/2024 HOT TUB PERMIT SET SITE PLAN, LAND USE CODE COMPLIANCE STATISTICS RESUB Sep 10 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • TO F.O. BRICK TO F.O. BRICK Ti 3/8"� 22'11/8"+/- 4'-8" 8'-0" 3'-2" 8'-0" 11'-31/2" +/- ` 9'-0" Ii Ii NEW ARCHWAY NEW ARCHWAY ` \ � NEW ARCHWAY 0 o WINDOW: 3' SiLL HT WINDOW: 3' SiLL HT `\ 7HEIGHT (VERIFY) (VERIFY) \ PER STRUCTURAL PER STRUCTURAL PER STRUCTURAL 0 A I I I I I I I A A3.1 A3.2 EX PATIO 1 EX S.O.G. 1 A4.1 A4.2 r--------� I I INSTALL CONCRETE WALL AND SLAB INSTALL ONCRETE WALL AND SLAB I I I AREA PER STRUCTURAL URALOVE PATIO FLOOR THiS AREA P/ PATIOOVE FLOOR THIS STRUCTURAL RUC URA L HOSE 13113; VERIFY LOCATION INSTALL GAS STUB FOR HOT TUB HEATER HOT TUB EQUIPMENT PER KR15CO POOLS INSTALL HOSE BiB W/ T-OFF FOR HOT TUB AUTOFiLL VERIFY CENTERLINE OF NEW STUD WALL TO MATCH CENTERLINE OF EX STUD WALL VERIFY STUD WALL LOCATION CLEAR OF + EX DUCTING EXISTING HVAC DUCTING TO REMAIN; VERIFY LOCATION ---1r------------------- -- ----I ——————————-----—�'--I = I NEW DROPPED BEAM EX POSTS & + I II I II PER STRUCTURAL BEAMS TO -1 I 17'1 +/- I = REMAIN; STORAGE MODIFY PER AREA 01 4'-91/2" HTR STRUCTURAL RAT 5LAB 18'-6" 8'-�"I (UNCONDITIONED) p I L----- �— — — -------, — —— i I ,POOL RT CL O FLTR z � Q NEW WALL PER .15 80 CFM FAN, VENT STRUCTURAL AT TO OUTSIDE crRc u + AREA OF CURVED o5K 50 CFM FAN, VENT E P M OJT SUC TO OUTSIDE o WALL DEMO I IT 11'-7 5/8" +/- 3'-41/2" 7'1 o2 SPA EX ELECTRICAL GUEST PANE PANELS REMAIN; CARPET UPGRADES REQ'D. F� INSTALL GAS 2X6 PLUMBING WALL STUB FOR WATER = NE 13 BATH TEMPERED FRAMELESS GLASS I HEATER (2) F �' TILE SHOWER PANEL & DOOR W CU T1 WC_ iL - 15'-41/2" W SHWR SHLV 1'-11" 13'-51/2" MECH 4'6"X4'6" - EX S.O.G. (c>) 2X6 PLUMBING WALL W/D F 13UILT-iN CLOSET HEAT HEAT UMP LIMP SHWR 5'X3'3" BATH TiLE Q 10 I � NEW-EL€CTKIO-FIKEftL 24'-01/4" +/- 19'13/4" NEW ARCHWAY 7HEIGHT PER STRUCTURAL ----- 3- 6-2 1/8" - J , 10'-1 3/4" -EX POSTS & BEAMS TO REMAIN; MODIFY PER STRUCTURAL TEMPERED FRAMELESS GLASS SHOWER PANEL & DOOR I� 80 CFM FAN, VENT TO OUTSIDE REC TiLE TEMPERED GLASS WALL AND POOR — � � • I � , � � � • iiiiiiiiiiiaiiiii aiiiiiiiiiaiiiiiiiiiaiiiiiiiiiiiiiiiiiiiiiiiiiiiiaiiiiiiiiiiiiiiiiiii�', d r DUCTING cz LD d) — - - 77—G.L.GLASS WALL cp 3'-3" 3'--4" TEMPERED WiNE ROOM LAYOUT +/- GLA55 WALL PER WiNE ROOM _ DOORCN CONSULTANT ------,,AND WINE TiLE 1 R 0 71/2' A r I 1479 1" I L ND1 G UP A3.0 _ I H D LH _=6 =_ 0) LD L1ZL 0) I I I I I I SiNK I I I I I I I TR I` i i -----T----T-- -- I I I I I---------�—� DUCTLESS MiNi SPLIT FOR WiNE ROOM TEMP CONTROL. INSTALL HUMIDITY CONTROL. VERIFY LOCATION AND SYSTEM PRIOR TO CONSTRUCTION. REFER TO WiNE ROOM CONSULTANT FOR ADDITIONAL INFORMATION AND HVAC REQ'TS 0 EXISTING WALLS ® NEW WALLS LOWER FLOOR PLAN SCALE:1/4" = 1-0" SCREEN WALL TO START AT TREADS FROM LANDING TO MAiN FLOOR. REFER TO DETAILS. A3.1 64'11/2"+/- r, UP 09 7" THEATER ENG. HARDWOOD UP 711 OUTLINE OF EX GARAGE FOUNDATION ABOVE- 1'-41/4"+/ HOT TUB BY OTHERS +/- 7'1 1'-2 1/2"+/ -7 7/8" EXISTING PLANTER AND RETAINING WALLS ti F y�,� COVERED PATIO S.O.G. (SLOPE AWAY FROM HOUSE) z 4'13/4" 7'-3" 4'-10 7/8" +/- 5'-1' — — LL `s EV o + 02 O4 ALIGN x\ � O INSTALL NEW DOOR iN EX R.O. WIDTH 0 I I o7 GYM - RUBBER TiLE OVER EX S.O.G. i I F I I:E 80 CFM FAN, VENT Im TO OUTSIDE. INSTALL I Imo, W/ HUMIDITY DETECTION II INSTALL SUPPORT II II PER STRUCTURAL FOR CEILING MOUNT BOXING BAG. VERIFY LOCATION W/ OWNER A A3.2 5'1 1/8"+/- Ia ± 05 \ STORAGE AREA RAT SLAB (UNCONDITIONED) EX C.O. 0 _------------- STORAGE EX S.O.G. 12'1 1/4"+/- HOT/COLD HOSE BiB; VERIFY LOCATION CONNECT NEW HOT TUB DRAIN TO EX CLEANOUT IEL B A3.1 LD N N 7'1 +/- 1 - A 0 A4.0 A3.0 2- N N INSTALL RACKS FOR HOME AUTOMATION STORAGE REQUIREMENTS VERIFY LOCATION AND SiZE NOTES: 1. ALL DIMENSIONS ARE GIVEN TO THE FACE OF STUD UNO. 2. ALL DOOR AND WINDOW DIMENSIONS ON THiS PLAN ARE TO CENTERLINE OF ROUGH OPENING; REFER TO SCHEDULE & MANUFACTURER FOR OPENING SiZE. 3. SEE ATTACHED WSEC FORMS FOR ENERGY CODE COMPLIANCE INFORMATION. 4. INSTALL SMOKE DETECTORS (S.D.) AT LOCATIONS SHOWN. HARDWIRE AND INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 5. INSTALL CARBON MONOXIDE ALARMS (C.M.D.) OUTSIDE EACH SEPARATE SLEEPING AREA iN THE IMMEDIATE VICINITY OF THE BEDROOMS. THE ALARM SHALL BE LISTED AS COMPLYING WiTH UL 2034 AND SHALL BE INSTALLED iN ACCORDANCE WiTH iRC R315.3 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. HARDWIRE AND 7'1 /- INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 6. SMOKE DETECTORS (S.D.) AND CARBON MONOXIDE ALARMS (C.M.D.) TO BE INSTALLED 3'-0" MiNiMUM FROM DATHROOM DOORS. LIJ U z 0 � N w � O m Q w 0 uj N 00 Z O J � O Lu U s7�s REGISTERED ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H H 2 D A R C H I T E C T U R E + D E SI G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 4/10/2024 HOT TUB PERMIT SET LOWER FLOOR PLAN RESUB Sep 10 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 89'-8 7/8"+l- �Z