Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB 1-BLD2024-0896+Heater+9.9.2024_1.19.06_PM+4488460
BLD2024-0896 RESUB Sep 10 2024 oEVE )PM PENTAIR BY of PA CITY OF EDMONDS MASTERTEMP° POOL AND SPA HEATER INSTALLATION AND USER'S GUIDE �,&WARNING I FOR YOUR SAFETY - READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. For additional free copies of this manual; call (800) 831-7133. FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualified inpool/spa heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Pentair Water Pool and Spa strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty. 120/240 VAC NATURAL GAS/LP GAS Models Natural Propane 175K BTU/HR 460792 460793 1PENTA,R 200K BTU/HR (ASME) 461000 461001 200K BTU/HR 460730 460731 200K BTU/HR (HDASME) 461032 — 250K BTU/HR 460732 460733 250K BTU/HR (HD) 460806 — OWNER: 250K BTU/HR (ASME) 460771 460772 ��® Retain For 250K BTU/HR (HDASME) 461020 — Future 300K BTU/HR 460734 460735 Reference 400K BTU/HR 460736 460737 400K BTU/HR (HD) 460805 — 400K BTU/HR (ASME) 460775 460776 400K BTU/HR (HDASME) 461021 — pE51�N SP +T. �fNTIFlEOTM AWAR NING Improper installation, adjustment, alteration, service or maintenance can cause propertydamage, personal injury or death. Installation and service must be performed by a qualified installer, service agency or the gas supplier. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. FOR Do not touch any electrical switch; do not use any phone in your building. YOUR Immediately call your gas supplier from a neighbor's phone. SAFETY 00 NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances. Pentair Inc. 1620 Hawkins Ave., Sanford, NC 27330 •(800) 831-7133 or(919) 566-8000 10951 W. Los Angeles Ave., Moorpark, CA 93021.(800) 831-7133 or(805) 553-5000 2 Section 1. Heater Identification Information To identify the heater, see rating plate on the inner front panel of the heater. There are two designators for each heater, one is the Model Number and the other is the Heater Identification Number (HIN). a. Heater Identification Number (HIN) The following example simplifies the identification system: 1) MT: MasterTemp 2) Model Size: (175, 200, 250,300 or 400) : Input rating (Btu/hr) X 1000 3) Fuel Type : (LP = Propane gas or NA = Natural gas) 4) Construction : (STD = Standard Model) (HD = Heavy Duty Model) (ASME = ASME Certified Model) (HD ASME = Heavy Duty ASME Model) HEATER IDENTIFICATION INFORMATION — (HIN) H. I. N. HEATER IDENTIFICATION NUMBER ID DESIGNATOR FOR PENTAIR AQUATIC SYSTEMS MASTERTEMP°HEATERS Example: 1 2 3 4 .L ODEL ME MODEL MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 2. Warning and Safety Instructions 3 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS MASTERTEMP° Pool and Spa Heater Congratulations on your purchase of the MasterTemp Pool and Spa Heater. Proper installation and service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MasterTemp heater is a compact, lightweight, efficient, induced -draft, gas fired high performance pool and spa heater that can be directly connected to schedule 40 PVC pipe. The MasterTemp heater also comes equipped with the Pentair multifunction temperature controller which shows, at a glance, the proper functioning of the heater. All MasterTemp heaters are designed with a direct ignition device, HSI (hot -surface ignition), which eliminates the need for a standing pilot. The MasterTemp heater requires an external power source (120/240 VAC 60 Hz) to operate. See Electrial Connections, page 32. SPECIAL INSTRUCTIONS TO OWNER: Retain this manual for future reference. This instruction manual provides operating instructions, installation and service information for the MasterTemp high performance heater. The information in this manual applies to all MasterTemp heater models. READ AND REVIEW THIS MANUAL COMPLETELY, it is very important that the owner/installer read and understand the section covering installation instructions, and recognize the local and state codes before installing the MasterTemp heater. Its use will reduce service calls and chance of injury and will lengthen product life. History and experience has shown that most heater damage is caused by improper installation practices. IMPORTANT NOTICES For the installer and operator of the MasterTemp heater: The manufacturer's warranty may be void if, for any reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual. If you need any more information, or if you have any questions regarding to this pool heater, please contact Pentair Water Pool and Spa at (800) 831-7133. WARRANTY INFORMATION The MasterTemp 125 pool and spa heater is sold with a limited factory warranty. Specific details are described on the warranty registration card which is included with the product. Return the warranty registration card after filling in the serial number from the rating plate inside the heater. Pentair has high standards of excellence include a policy of continuous product improvement resulting in your state-of- the-art heater. We reserve the right to make improvements which change the specifications of the heater without incurring an obligation to update the current heater equipment. These heaters are designed for the heating of chlorine, bromine or salt system swimming pools and spas or in non -stationary installations, and should never be employed for use as space heating boilers or general purpose water heaters. The manufacturer's warranty may be void if, for any reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual. CAUTION OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 680 F. WILL CAUSE HARMFUL CONDENSATION AND WILL DAMAGE THE HEATER AND VOID THE WARRANTY. Do not use the heater to protect pools or spas from freezing if the final maintenance temperature desired is below 680 F., as this will cause condensation related problems. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 4 Section 2. Warning and Safety Instructions CODE REQUIREMENTS Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code, ANSI Z223.1 and the latest edition of the National Electrical Code, NFPA 70 (US). Installation in Canada must be in accordance with the latest CAN/CGA-B 149.1 or .2 and CSA C22.1 Canadian Electric Code, part 1. The heater, when installed, must be electrically grounded and bonded in accordance with local codes, or, in absence of local codes, with the National Electrical Code, ANSI/NFPA70 (US) or in Canada in accordance with the Canadian pE51Gly SP SA CERTIFIED CfRiIF1E0 TM TM ©DANGER CARBON MONOXIDE GAS IS DEADLY— Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas you cannot see or smell. CONSUMER INFORMATION AND SAFETY ©WARNING The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous. See below for water temperature guidelines before setting temperature. 1. Spa or hot tub water temperatures should never exceed 104' F (40' Q. A temperature of 100' F (38' C) is considered safe for a healthy adult. Special caution is suggested for young children. 2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning. 3. Pregnant women beware! Soaking in water above 102' F (39' C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a brain -damaged or deformed child). Pregnant women should stick to the 100' F (38' Q maximum rule. 4. Before entering the spa or hot tub, the user should check the water temperature with an accurate thermometer. Spa or hot tub thermostats may err in regulating water temperatures by as much as 4° F (2.2° Q. 5. Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their physician's advice before using spas or hot tubs. Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of control system and gas control which has been under water. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 2. Warning and Safety Instructions s SAFETY INFORMATION The MasterTemp° pool heaters are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual. Throughout the manual, safety warnings and cautions are identified by the "A symbol. Be sure to read and comply with all of the warnings and cautions. ©DANGER — CARBON MONOXIDE GAS IS DEADLY READ OWNERS MANUAL COMPLETELY BEFORE OPERATING THIS PRODUCT MUST BE INSTALLED AND SERVICED BY A PROFESSIONAL SERVICE TECHNICIAN, QUALIFIED IN POOL HEATER INSTALLATION. Some jurisdictions require that installers be licensed. Checkwith your local building authority about contractor licensing requirements. Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper installation and/or operation will void the warranty. Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas you cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness, headache, nausea, weakness, sleepiness, muscular twitching, vomiting and inability to think clearly. IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY TURN OFF THE POOL HEATER, LEAVE THE VICINITY OF THE POOL OR SPAAND GET INTO FRESH AIR IMMEDIATELY. THE POOL HEATER MUST BE THOROUGHLY TESTED BY A GAS PROFESSIONAL BEFORE RESUMING OPERATION. EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH. NEVER use this pool heater indoors without specified ventilation system (and properly installed vent pipe). NEVER use this pool heater in the home or in partly enclosed areas (such as garages), unless the specified ventilation system is used. If used outdoors, install far from open windows, doors, vents and other openings. Pentair strongly recommends that all vents, pipes and exhaust systems be initially and periodically tested for proper operation. This testing can be accomplished by using a hand-held carbon monoxide meter and/or by consulting with a gas professional. Pool heaters must be used in conjunction with carbon monoxide detectors installed near the pool heater. The carbon monoxide detectors must be periodically inspected for proper operation so as to insure continued safety. Broken or malfunctioning carbon monoxide detectors must be replaced immediately. ©WARNING — FOR YOUR SAFETY This product must be installed and serviced by a professional service technician, qualified in pool heater installation. Some jurisdictions require that installers be licensed. Checkwith your local building authority about contractor licensing requirements. Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper installation and/or operation will void the warranty. ©WARNING — This heater is equipped with an unconventional gas control valve that is factory set with a manifold pressure of -.2 inches wc. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation or service must be performed by a qualified installer, service agency or the gas supplier. If this control is replaced, it must be replaced with an identical control. Do not attempt to adjust the gas flow by adjusting the regulator setting. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 6 Section 2. Warning and Safety Instructions SAFETY INFORMATION, (cont'd.) ©WARNING — Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a heater set up for natural gas on propane gas or vice versa. Only qualified service technicians should attempt to convert heater from one fuel to the other. Do not attempt to alter the rated input or type of gas by changing the orifice. If it is necessary to convert to a different type of gas, consult your Pentair dealer. Serious malfunction of the burner can occur which may result in loss of life. Any additions, changes, or conversions required in orderfor the appliance to satisfactorily meet the application needs must be made by a Pentair dealer or other qualified agency using factory specified and approved parts. The heater is available for use with natural gas or LP (propane) gas only. It is not designed to operate with any other fuels. Refer to the nameplate for the type of gas the heater is equipped to use. • Use heater only with the fuel for which it is designed. • If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier before putting the heater into operation. ©WARNING — Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. ©WARNING — Risk of explosion if unit is installed near propane gas storage. Propane (LP) gas is heavier than air. Consult local codes and fire protection authorities about specific installation requirements and restrictions. Locate the heater away from propane gas storage and filling equipment as specified by the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). ©WARNING — Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks. Only qualified service technicians should attempt to service the heater, as leakage of exhaust products or flammable gas may result from incorrect servicing. ©WARN I NG — Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not use a drafthood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. The heater is supplied with an integral venting system for outdoor installation. A vent conversion kit (See Page 29 for Part Numbers for Conversion Kits) is available for installations indoors (US and Canada). Use the specified venting, and only the specified venting, when heater is installed in an enclosure or indoors. ©CAUTION — Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Wiring errors can also destroy the control board. • Connect heater to 120 or 240 Volt, 60 Hz., Single Phase power only. • Verify proper operation after servicing. • Do not allow children to play on or around heater or associated equipment. • Never allow children to use the pool or spa without adult supervision. • Read and follow other safety information contained in this manual prior to operating this pool heater. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 2. Warning and Safety Instructions 7 CONSUMER INFORMATION AND SAFETY .WARNING The U.S. Consumer Product Safety Commission warns that carbon monoxide is an "invisible killer". Carbon monoxide is a colorless and odorless gas. l . Carbon monoxide is produced by burning fuel, including natural gas and propane. 2. Proper installation, operation and maintenance of fuel -burning appliances in the home is the most important factor in reducing carbon monoxide poisoning. 3. Be sure that fuel burning appliances such as heaters are installed by professionals according to manufacturer's instructions and codes. 4. Always follow the manufacturer's directions for safe operation. 5. Have the heating system (including vents) inspected and serviced annually by a trained service technician. 6. Examine vents regularly for improper connections, visible cracks, rust or stains. 7. Install battery -operated carbon monoxide alarms. The alarms should be certified to the requirements of the most recent UL, IAS, CSA and IAPMO standard for carbon monoxide alarms. Test carbon monoxide alarms regularly and replace dead batteries. GENERAL SPECIFICATIONS NOTICE: • Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty. • The Combination Gas Control Valve on this heater differs from most appliance gas controls. If it must be replaced, for safety reasons replace it only with an identical gas control. • The access door panels must be in place to provide proper ventilation. Do not operate the heater for more than five (5) minutes with the access door panels removed. • This heater is design certified by CSA International as complying with the Standard for Gas Fired Pool Heaters, ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas. • The heater is designed for the heating of chlorine, bromine or salt system swimming pools and spas. It should NOT be used as a space heating boiler, or general purpose water heater. • The heater is design certified by CSA International for installation on combustible flooring. Specified minimum clearances must be maintained to combustible surfaces (see "Heater Clearances", page 22). • The heater should be located in an area where leakage of the heater or connections will not result in damage to the area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow. • The heater may not be installed within 5 ft. (1.5M ) of the inside surface of a pool or spa unless it is separated by a solid fence, wall or other permanent barrier. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 8 Customer Service 8:00 AM to 8:00 PM Phone: (800) 831-7133 Fax: (800) 284-4151 Visit www.pentair.com Contents Technical Support Sanford, North Carolina (8:00 AM to 8:00 PM ET) Phone: (919) 566-8000 Fax: (919) 566-8920 Moorpark, California (8:00 AM to 5:00 PM PT) Phone: (805) 553-5000 - Fax: (805) 553-5515 Section 1. Heater Identification Information......................................................................... 2 Section 2. Warning and Safety Information.......................................................................... 3 ImportantNotices................................................................................................................................................................................. 3 WarrantyInformation............................................................................................................................................................................ 3 CodeRequirements.............................................................................................................................................................................. 4 Consumer Information and Safety Information..................................................................................................................................... 4-7 GeneralSpecifications.......................................................................................................................................................................... 7 Section3. Installation.............................................................................................................. 10 HeaterDescription................................................................................................................................................................................ 10 Puttingthe Heater into Service............................................................................................................................................................. 10 Specifications....................................................................................................................................................................................... 11 PlumbingConnections.......................................................................................................................................................................... 12 WaterConnections............................................................................................................................................................................... 12 MultipleHeater Installation................................................................................................................................................................... 13 Valves................................................................................................................................................................................................... 14 ManualBy-Pass................................................................................................................................................................................... 14 AutomaticBy-Pass............................................................................................................................................................................... 15 BelowPool Level Installation................................................................................................................................................................ 15 GasConnections.................................................................................................................................................................................. 16 SedimentTraps................................................................................................................................................................................... 16 GasPipe Escutcheon Installation......................................................................................................................................................... 17 GasPipe Sizing.................................................................................................................................................................................... 18 Testing Gas Pressure / Gas Pressure Requirements........................................................................................................................... 19-20 Outdoor Installation Located Outdoor, Using the Built -In Stackless Venting System / Heater Clearances - Outdoor .......................... 20-21 Indoor Venting — General Requirements (Category I and Category III requirements)...................................................................... 22 Heater Clearances — General Requirements (Indoor Installation US / Canada)............................................................................ 22 OutsideVent Cover Removal............................................................................................................................................................... 22 Combustion Air Supply / Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation).................................................................. 23-24 Corrosive Vapors and Possible Causes............................................................................................................................................... 24 Vent Installation (Indoor Installation (Category 1) for US and Canada)................................................................................................ 25 VerticalVenting - Negative Pressure................................................................................................................................................... 25 - 29 Horizontal or Vertical Venting - Positive Pressure (Category III)......................................................................................................... 29 Connecting Special Metalic Gas Vent to the Heater............................................................................................................................. 29 - 32 Garage or Utility Room Installation (US & Canada)............................................................................................................................. 32 ControlPanel Positioning..................................................................................................................................................................... 33 FinalInstallation Check........................................................................................................................................................................ 33 ElectricalConnections.......................................................................................................................................................................... 33-34 HeaterBonding..................................................................................................................................................................................... 35 Remote Control Connections (Fireman's Switch Connection).............................................................................................................. 36 Connecting the MasterTemp Heater to the IntelliCenter Control System Load Center........................................................................ 37-39 MasterTempHeater Wiring Diagram.................................................................................................................................................... 40 MasterTemp Heater Electrical Schematic Ladder Diagram.................................................................................................................. 41 P/N 472592 Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Contents (Continued) 9 Section4. Operation................................................................................................................ 42 BasicSystem Operation....................................................................................................................................................................... 42 MasterTemp HEater HSI (Hot -Surface Ignition) Ignition Lighting / Operation...................................................................................... 42 Start -Up and Operation....................................................................................................................................................................... 42 Before Start -Up / What to do if you smell gas..................................................................................................................................... 42 OPERATINGINSTRUCTIONS............................................................................................................................................................ 43 ToTurn Off Gas to Appliance............................................................................................................................................................. 43 Safety Controls - Air Flow Switch (AFS)............................................................................................................................................ 44 WaterPressure Switch................................................................................................................................................................... 44 HighLimits (Safety Device)............................................................................................................................................................ 44 OperationOf Ingition Module.......................................................................................................................................................... 45 ControlPanel Description..................................................................................................................................................................... 46 MenuNavigation................................................................................................................................................................................... 46 Operatingthe Heater............................................................................................................................................................................ 46 Menu..................................................................................................................................................................................................... 46 Section 5. Troubleshooting.................................................................................................... 48 InitialTroubleshooting........................................................................................................................................................................... 48 Errorand Fault Codes.......................................................................................................................................................................... 48 Initial Troubleshooting and Troubleshooting Chart............................................................................................................................... 49 HeaterWill Not Fire-A...................................................................................................................................................................... 50 HeaterWill Not Fire - B...................................................................................................................................................................... 51 IGN is ON Alarms: AGS, AFS, HLS, PS Thermistor.......................................................................................................................... 52 Diagnostic Alarms: AGS, AFS, HLS, PS........................................................................................................................................... 53 DiagnosticsAlarms: SFS................................................................................................................................................................... 54 BurnerTroubleshooting........................................................................................................................................................................ 55 HeatExchanger Troubleshooting......................................................................................................................................................... 55 Section6. Maintenance........................................................................................................... 56 Careand Maintenance......................................................................................................................................................................... 56 Pressure Relief Valve (Not Factory Installed)....................................................................................................................................... 56 WaterPipe Escutcheon Installation...................................................................................................................................................... 57 AfterStart -Up (Checking Water Flow).................................................................................................................................................. 58 Springand Fall Operation..................................................................................................................................................................... 58 WinterOperation.................................................................................................................................................................................. 58 MaintainingPool Temperature.............................................................................................................................................................. 59 EnergySaving Tips............................................................................................................................................................................... 59 Chemical Balance (Pool and Spa Water)............................................................................................................................................. 59-60 Section 7. Replacement Parts................................................................................................ 61-65 Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 10 Section 3. Installation Instructions HEATER DESCRIPTION Figure 1 is a diagram of the heater showing how it operates. Precisely matched orifice plates meter the air and gas into the mixer. The blower draws the air and gas through the mixer and forces it into the burner's flame holder. A sealed heat exchanger surrounds the flame holder, discharging exhaust gases out the flue. Two inch PVC water piping connects directly to the manifold/ header on the heat exchanger using 2" PVC slip unions provided with the heater. The outer manifold remains cool; no heat sinks are required. A thermal regulator and an internal bypass regulate the water flow through the heat exchanger to maintain the correct outlet temperature. The heater operator control panel board assembly is located on top of the heater. SEQUENCE OF OPERATION An electronic temperature sensing thermistor in the manifold adapter inlet controls the heater operation. When the inlet water t Air w Blower Mixer Inlet (Cold Water) Outlet (Mixed Water) Burner � Heating Coils Figure 1. temperature drops below the temperature set on the operating control, the burner controller supplies power to the combustion air blower through a series of safety interlocks. The interlocks consist of: • the pressure switch (PS), which senses that the pump is running, • the high limit switch (HLS), which opens if the heat exchanger outlet temperature goes above 135' F (57' C), and • the air flow switch (AFS), which senses the pressure drop across the air metering orifice, • the automatic gas shut-off (AGS) switch, which opens if the heat exchanger outlet temperature goes above 140' F (60° Q. • the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 480' F (249' C). The air flow switch (AFS) senses the pressure drop across the air metering orifice. As soon as there is sufficient air flow, the AFS closes, closing the circuit to the hot surface igniter (HSI), which ignites the fuel mixture. On a call for heat, the blower and HSI are energized. In about 20 seconds, the gas valve opens and ignition occurs. The HSI then switches to a sensing mode and monitors the flame. The heater is equipped with a digital operating control that enables the user to pre-set the desired pool and spa water temperatures. The control enables the user to select between pool and spa heating, and features a digital display that indicates the water temperature and heater set point. PUTTING THE HEATER INTO SERVICE If the heater is installed below the level of the pool, or more than two feet above pool level, the pressure switch setting should be adjusted. See WATER PRESSURE SWITCH, (page 44) in the SAFETY CONTROLS Section. Before putting the heater into service for the first time, follow the instructions under "BEFORE START-UP" (page 42) in the front of this manual. Check for proper operation of the heater by following the steps under "OPERATION INSTRUCTIONS." (page 42). Damage to equipment caused by improper installation or repair will void the warranty. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 11 SPECIFICATIONS These installation instructions are designed for use by qualified personnel only, trained especially for installation of this type of heating equipment and related components. Some states require installation and repair by licensed personnel. If this applies in your state, be sure your contractor bears the appropriate license. See Figure 2 for Outdoor and Indoor Installations. 5" CM) FRONT CON[ m) 3e (82. 0o Anil TOP EXHAUST SIDE PLUMBING SIDE 10.13" (25.7 cm) 5.6" (14.2 cm) Figure 2. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 12 Section 3. Installation Instructions PLUMBING CONNECTIONS The MasterTemp heater has the unique capability of direct schedule 40 PVC plumbing connections. A set of bulkhead fittings is included with the MasterTemp heater to insure conformity with Pentair's recommended PVC plumbing procedure. Other plumbing connections can be used. See Figure 3 for plumbing connections. Before operating the heater on a new installation, turn on the circulation pump and bleed all the air from the filter using the air relief valve on top of the filter. Water should flow freely through the heater. Do not operate the heater unless water in the pool/spa is at the proper level. If a manual by-pass is installed, temporarily close it to insure that all air is purged from the heater. WATER CONNECTIONS The heater requires proper water flow and pressure for its operation. See Figure 4 for the recommended installation. The filter pump discharges to the filter, the filter discharges to the heater, and the heater discharges directly to the pool or spa. Amanual bypass valve should be installed across the heater when the pump flow exceeds 120 GPM (454 LPM). See "WATER FLOW RATE" on page 14 (Table 1) for setting of the manual by-pass valve. Make sure that the outlet plumbing from the heater contains no shut-off valves or other flow restrictions that could prevent flow through the heater (except for pool installations as noted below, or winterizing valves where needed). To switch flow between the pool and spa, use a diverter valve. Do not use any valve that can shut off the flow. Install the chemical feeder downstream of the heater. Install a chemical resistant one-way check valve between the heater and the chemical feeder to prevent back -siphoning through the heater when the pump is off. FROM POOL Figure 3. 3-Way Chlorinator Valve Check Main Drain p Filter Pool Spa Pum t From Pool 3-Way 3-Way Valve Valve Figure 4. NOTICE: If the heater is plumbed in backwards, it will cycle continuously. Make sure piping from filter is not reversed when installing heater. Connect the heater directly to 2" PVC pipe, using the integral unions provided. Heat sinks are not required. The low thermal mass of the heater will prevent overheating of the piping connected to the pump even if the heater shuts down unexpectedly. Occasionally a two -speed pump will not develop enough pressure on the low speed to operate the heater. In this case, run the pump at high speed only to operate the heater. If this does not solve the problem, do not try to run the heater. Instead, correct the installation. Note: Do not operate the heater while an automatic pool cleaner is also operating. If the circulation pump suction is plugged (for example by leaves), there may not be adequate flow to the heater. Do not rely on the pressure switch in this case. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 13 MULTIPLE HEATER INSTALLATION All plumbing on multiple heater installations must be done in parallel. See Figure 5 and Figure 6. To prevent heater overheating and to ensure heater longevity, water flow to each heater must be balanced for optimum operation. To meet recommended flow rates, be sure all installed pipes are installed in accordance with local and state codes. To allow for proper operation and service clearance, maintain spacing to adjacent heaters. Heaters installed too close to one another may encounter operational issues associated with exhaust fumes. Figure 5. Two MasterTemp® Heaters Plumbing Hydraulic Diagram T PORT ATER) LOWER OUTLET PORT (HOT WATER) Extend 12" (305 mm� past end heater inlet for hydraulic balancing and Flow Meters n heater inlets ystem 2" (305 mm) heater inlet wlic balancing Figure 6. Four MasterTemp Heaters Plumbing Hydraulic Diagram Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 14 Section 3. Installation Instructions VALVES When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping system to isolate the equipment from the pool or spa. Check valves are recommended to prevent back -siphoning. Back - siphoning is most likely to occur when the pump stops, creating a pressure -suction differential. Do NOT sanitize the pool by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high concentration of chlorine to enter the heater, which could cause corrosion damage to the heat exchanger. Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters or pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line is down stream of the heater, and is equipped with a positive seal noncorrosive "Check Valve", (PIN R172288), between the feeder and heater. MANUAL BY-PASS Where the water flow rate exceeds the maximum 120 GPM, a manual bypass should be installed and adjusted. After installing the valve, adjust the valve to bring the flow rate within the acceptable range. Then remove the valve handle or lock it in place to avoid tampering. See Figure 7. Cool water Warm water out 1. Set Manual By -Pass Valve. lh". 2. Remove Handle. Outlet to pool Figure 7. Inlet to heater Table 1. MODEL MIN. (GPM) (LPM) MAX. (GPM) (LPM) 175 20 (76) 120 (454) 200 20 (76) I 120 (454) 250 25 (95) 120 (454) 300 30 (114) 120 (454) 400 40 (152) 120 (454) * Do not exceed the maximum recommended flow rate for the connecting piping. * Pumps 2 HP or larger can produce water pressure flow in excess of 120 GPM. For these pumps, a BY-PASS VALVE is recommended. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 15 AUTOMATIC BY-PASS Figure 7a shows a plumbing diagram for an automatic BY-PASS (IntelliValve°). This in conjunction with an IntelliFlo VSF pump can provide added longevity of the heater and increased cost savings of operation. A 3-Port valve with an IntelliValve actuator is installed at the heater inlet. A check valve is installed at the heater oulet so that water cannot flow back into the heater. See instructions for Automatic Bypass valve kit (P/N 462048) for setting the open and closed position of the IntelliValve. Check Valve Figure 7a. IntelliValve Cold Water In Hot Water Out To Pool BELOW POOL LEVEL INSTALLATION If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified service technician. See following CAUTION before installation. BELOW OR ABOVE POOL INSTALLATION The water pressure switch is set in the factory at 3.00 PSI (± 0.75 PSI). This setting is for a heater installed at pool level. If the heater is to be installed more than 1' above or below, the water pressure switch must be adjusted by a qualified service technician. See page 44, Figure 38 FLOW SWITCH: If the heater is installed more than T above the pool or more than 4' below the pool level, you will be beyond the limits of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water pressure switch wires. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 16 Section 3. Installation Instructions GAS CONNECTIONS GAS LINE INSTALLATIONS FOR NEW HEATER INSTALLATION: SEE NEXT PAGE TO INSTALL THE GAS PIPE ESCUTCHEON. Before installing the gas line, be sure to check which gas the heater has been designed to burn. This is important because different types of gas require different gas pipe sizes. The rating plate on the heater will indicate which gas the heater is designed to burn. The Table 2, shown on page 18, show which size pipe is required for the distance from the gas meter to the heater. The table is for natural gas at a specific gravity of .65 and propane at a specific gravity of 1.55. When sizing gas lines, calculate three (3) additional feet of straight pipe for every elbow used. When installing the gas line, avoid getting dirt, grease or other foreign material in the pipe as this may cause damage to the gas valve, which may result in heater failure. The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances that may be used on the same meter The gas line from the meter will usually be of a larger size than the gas valve supplied with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction as close to the heater as possible. The heater requires a gas supply of not less than 4" (10.2 cm) we and not more than 14" (35.6 cm) wc. Gas supply pressures outside of this range may result in improper burner operation. A minimum flowing or dynamic inlet pressure (while the heater is running) of 4" (10.2cm) we is required to maintain input rating with no more than a 2" pressure drop between static and dynamic. The gas supply must be installed in accordance with the National Fuel Gas Code, ANSIZ223.1, or standard CSA B149.1, Natural Gas and Propane Installation Codes, as applicable and all applicable local codes. Install a manual shut-off valve and a sediment trap and union located outside the heater panels, see Figure 8. Do not use a restrictive gas cock. The following minimum gas pipe sizes are recommended for natural gas supply piping, see Table 2 on page 18. For low pressure LP gas, pipe size may be reduced by 1/4", with a minimum pipe size of 1/2". Check for compliance with local codes. The heater and any other gas appliances must be disconnected from the gas supply piping system during any pressure testing on that system, (greater than '/z PSI). The heater and its gas connection must be leak tested before placing the heater in operation. Do not use flame to test the gas line. Use soapy water or another nonflammable method. NOTE A manual main shut-off valve must be installed externally to the heater. ©WARNING DO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRANTY. SEDIMENT TRAPS Install a sediment trap and union located outside the heater panels in accordance with National code requirements. Do not use a restrictive gas cock. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet which can be removed for cleaning, as illustrated in Figure 8, or an other device recognized as an effective sediment trap. All gas piping should be tested after installation in accordance with local codes. 18-24" of 3/4" Manual Gas line from Shut-off Valve Valve 1" Dia. or larger (See "Recommended Pipe Sizes" Chart) Bell Reducer N i ®®®®® o lAt least 9" ®®® Union At least 3" ®®® Sedimen� e ®® Trap Figure 8. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 17 Required Parts: P/N 467107, Gas Pipe Escutcheon (PVC), P/N 270114, Phillips Retention Screw (#8) 1. IMPORTANT! Turn off the electrical supply to the heater and turn off the pump. © WARNING! Risk of fire or explosion. Never test for gas leaks with an open flame. The following escutcheon installation instructions are intended for new pool installations only, not for retrofit purposes. 2. When installing the 1/4" pipe into the gas valve, place the gas pipe escutcheon over the pipe so that the larger circle is facing the heater's service panel and the smaller circle with the screw is facing away for the heater service panel (toward the union) as shown in Figure 9. 3. Slide the escutcheon flush against the outside of the heater service panel and the gas pipe opening. Be sure to completely cover large gas pipe opening in the panel to prevent rodents to gain access to the inside of the heater. 4. Hand -tighten the retention screw to secure the escutcheon in place. 5. Safety check the gas pipe for leaks as instructed in BASIC SYSTEM OPERATIONS, page 42. I Knoc ren from Flange Figure 9. Flange installed on the gas pipe. Be sure the flange covers the circular opening in the heater panel. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 18 Section 3. Installation Instructions GAS PIPE SIZING STAGE TWO "LOW PRESSURE" GAS PIPE SIZING Table 2 PIPE SIZING FOR GAS LINE CONNECTIONS MAXIMUM EQUIVALENT PIPE LENGTH (Ft.) Natural Gas at 1000 B.T.U. per Cubic Foot Propane Gas at 2500 B.T.U. per Cubic Foot MODEL 1 /2" 3/4" 1 " 1-1 /4" 1-1 /2" 2" 2-1 /2" NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO 175 20' 30' 80' 125' 250' 450' 600' 200 20' 30' 80' 125' 250' 450' 600' 250 10' 20' 50' 70' 150' 250' 500' 600' - 300 - 10' 30' 50' 100' 200' 350' 400' 600' 400 - - 10' 20' 60' 100' 150' 200' 450' 400' MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 19 TESTING GAS PRESSURE Before operating the heater, the heater and its gas connections must be leak tested. Do NOT use an open flame to test for leaks. Test all gas connections for leaks with soapy water or another non-flammable method (see page 16). The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The heater must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure testing of the gas supply at test pressures equal to or less than 1/2 psig (3.5 kPa). CHECKING THE GAS PRESSURE THROUGH THE COMBINATION GAS CONTROL VALVE Risk of fire and explosion. Improper installation, incorrect adjustment, alteration, service, or maintenance of the Combination Gas Control Valve can lead to fire or explosion, causing loss of life, personal injury, and/or property damage. If it is necessary to adjust the gas valve, this must be done by only by a qualified service agency. These instructions are for the use of qualified service technicians only! This appliance is equipped with an unconventional gas control valve that is factory set with a manifold pressure of —.2" (-0.5cm) wc. Installation or service must be performed by a qualified installer, service agency, or the gas supplier. If this control valve is replaced, it must be replaced with an identical control. The combination gas valve incorporates dual shut-off valves and a negative -pressure regulator. For proper operation, the regulated pressure at the outlet manifold of the valve must be —0.2" (-0.5cm) we below the reference pressure at the blower mixer inlet, and the gas valve `VENT' tap must be connected to the end cap air orifice as shown in Figure 10. Do not attempt to adjust the gas input by adjusting the regulator setting. The correct gas regulator setting is required to maintain proper combustion and must NOT be altered. To Air Flow Switch Connection for Service To Gas To Air Flow Valve Vent Switch / To High Side of Differential Pressure Gauge Pressure Tap Inlet 1! Vent ° To Low Side of Differential Pressure Gauge Figure 10. Pressure Tap Connection for Test Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 20 Section 3. Installation Instructions ©CAUTION The use of Flexible Connectors (FLEX) is NOT recommended unless they are properly sized according to the supplier recommendations for the heater rating. GAS PRESSURE REQUIREMENTS Gas Pressure Model Natural Propane Inches W.C. Maximum Inlet MT 14 14 Minimum Inlet MT 4 4 Manifold MT -0.2 ± 0.1 -0.2 ± 0.1 NOTE: All readings must be taken while heater is operat- ing. Any adjustments or readings made while heater is off will result in performance problems. Table 3. OUTDOOR INSTALLATION LOCATED OUTDOORS, USING THE BUILT-IN STACKLESS VENTING SYSTEM. Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum Gases, ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA 13149.2 (latest edition) in Canada. Consult local codes and fire protection authorities about specific installation restrictions. Locate the heater on a level surface in an open area that is protected from drainage or run-off. Install the heater in an area where leaves or other debris will not collect on or around the heater. To avoid damage to the electronic components in the heater, take care to prevent prolonged exposure to driving sources of water (such as lawn sprinklers, heavy roof runoff, hoses, etc.). Avoid operation in persistent, extreme, moist or salty environments. In extreme weather, shut down the heater and disconnect the power to it until the weather has moderated. In areas subject to hurricanes or very high winds, purchase the Bolt Down Bracket Kit, P/N 460738. HEATER CLEARANCES — OUTDOOR IMPORTANT! • In an outdoor installation it is important to ensure water is diverted from overhanging eves with a proper gutter/drainage system. The heater must be set on a level foundation for proper drainage. • This unit shall not be operated outdoors at temperatures below -200 F. If the heater is located under a roof overhang, there must be at least three (3) feet (Im) of clearance between the bottom of the overhang and the top of the heater exhaust vent, see Figure 11. If the heater is under a roof overhang, the space around the heater must be open on three sides. DO NOT, under any circumstances, install the heater under ANY deck. For Heater mounting bolts and clamps, purchase separately Bolt Down Bracket Kit, Part No. 460738. a Lead v Anchor Figure 11. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 21 For minimum exhaust vent clearances for all building openings, including but not limited to vented eaves, doors, windows, gravity air inlet, see Figure 12, show below. In Canada, the heater must be installed with the top of the vent at least 10 feet (3m) below, or to either side of, any opening into a building. Orient the heater for convenient access to the water connections and the gas and electrical connections. Note: Check local building codes for installing the heater from any property line set back requirements (see the installation diagram below). ©CAUTION If installing the heater next to or near an air conditioning unit or a heat pump, allow a minimum of 36 in. (91.4 cm) between the air conditioning unit and the heater. Figure 12. OUTDOOR INSTALLATION VENTING GUIDELINES SIDE VIEW 6 in From building wall Exhaust Grill (Vent) Building e o Figure 13. From window or door d' Property Line-j 'des .a`e KNII o. eow ao� Gr Seib Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 22 Section 3. Installation Instructions INDOOR VENTING — General Requirements The heater may be installed as a Category / or Category It/ appliance. Vented Appliance (Category I) — vertical only An appliance that operates with a nonpositive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent, see pages 25-28. Vented Appliance (Category I//) — vertical or Horizontal An appliance that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent, see pages 29-32. If you are considering connecting this heater to a pre-existing vent system, make sure that the vent system meets the appropriate venting requirements as given in this manual on pages 22-32. If not, replace the vent system. DO NOT use a draft hood with this heater. The MasterTemp heaters are capable of a 270-degree discharge rotation and operate with a positive vent static pressure and with a vent gas temperature less than 400' F (204' Q. The total length of the horizontal run must not exceed the length that is listed in Table 5 on page 24. HEATER CLEARANCES General Requirements INDOOR INSTALLATION (US / CANADA) The following clearances must be maintained from combustible surfaces: TOP ............................. 6 in. (15 cm) EXHAUST SIDE .......... 6 in. (15 cm) HEADER SIDE ............ 6 in. (15 cm) DOOR PANELS* ........ 6 in. (15 cm) Note (*) For service access it is advisable to allow for sufficient clearance on at least one door panel. The heater is design certified by CSA International for installation on combustible flooring. For installation on carpeting, the heater must be mounted on a metal or wood panel that extends at least three (3) inches beyond the base of the heater. If the heater is installed in a closet or alcove, the entire floor shall be covered by the panel. On an outdoor shelter installation, the exhaust discharges into a vent pipe. Orient the heater so that the vent pipe does not interfere with adjustment of the operating controls. The control panel located on the top panel can be rotated to any of the three sides of the heater for easy access. However, the control panel must not be located on the side where the vent is located. OUTSIDE VENT COVER REMOVAL The heater is supplied from the factory with a built-in stackless outside vent for outdoor installation. Remove the outside vent cover for outdoor shelter installation. (') For service access, it is advisable to allow for sufficient clearance on at least one door panel. 6 in. 6 in.* 6 in. Figure 14. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 23 COMBUSTION AIR SUPPLY For indoor installation, the heater location must provide sufficient air supply for proper combustion and ventilation of the surrounding area. The minimum requirements for the air supply specify that the room in which a heater is installed should be provided with two permanent air supply openings; one within 12 inches (30 cm) of the ceiling, the other within 12 inches (30 cm) of the floor for combustion air, in accordance with the latest edition of ANSI Z223.1, or the National Fuel Gas code, the CSA B 149.1, Natural Gas and Propane Installation Codes, as applicable, and any local codes that may apply. These openings shall directly, or through duct, connect to outdoor air. Note: For indoor installations where combustion air might be insufficient, see "Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation) " below. Air Supply Requirements Guide for MasterTemp Heaters Minimum Net Free Open Area for Each Opening* (Square Inches/Centimeters) All Air From Inside Building All Air From Outside Building Model Combustion Vent Combustion Vent 175 200 sq. in. 200 sq. in. 50 sq. in. 50 sq. in. 1290 sq. cm. 1290 sq. cm. 323 sq. cm. 323 sq. cm. 200 200 sq. in. 200 sq. in. 50 sq. in. 50 sq. in. 1290 sq. cm. 1290 sq. cm. 323 sq. cm. 323 sq. cm. 250 250 sq. in. 250 sq. in. 63 sq. in. 63 sq. in. 1613 sq. cm. 1613 sq. cm. 406 sq. cm. 406 sq. cm. 300 300 sq. in. 300 sq. in. 75 sq. in. 75 sq. in. 1935 sq. cm. 1935 sq. cm. 484 sq. cm. 484 sq. cm. 400 400 sq. in. 400 sq. in. 100 sq. in. 100 sq. in. 2580 sq. cm. 2580 sq. cm. 645 sq. cm. 645 sq. cm. * Area indicated is for one of two openings; one at floor level and one at the ceiling. Table 4. Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation) For indoor heater installations where combustion air supply might be insufficient, the MasterTemp® Heater is certified for a direct air intake duct using 3-inch PVC pipe. If outside air is drawn through 3" PVC duct directly into the heater, PVC pipe can be installed in accordance with the following requirements: The air intake opening MUST be installed at least 1 ft. above the roof line or normal snow levels for free air flow. The Category I or III exhaust vent termination cap must have at least 3 ft. minimum vertical clearance from air intake duct. (See diagram on page 24, and table 5). Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 24 Section 3. Installation Instructions Combustion Air Intake 3" (80 MM) PVC Pipe ((Alternate Location) Flue Exhaust Vent Cap and Riser - ' provided by installer(30 CM) MIN. Chimney or Gas Vent (Category I or III) I I I ---------------------- �I- ______________ ______ I 1 I II Chimney or Gas Vent (Category I or III) , I I , I tHeatei , I , I , I , I , I I Side Wall Vent Flue Exhaust Vent Cap (Alternate Location) Combustion Air Intake 3" O PVC Pipe 36" (1 M) MIN. 6" 12" (30 CM) MIN. (15 CM) MIN. Combustion 3 in. PVC Pipe Inlet Air Intake Duct Requirements* Combustion Air Intake 3 in. Pipe (Vertical or Horizontal) No. of 90° Elbows Maximum Length in Feet (M) 0 70 ft. (21.3 M) 1 58 ft. (17.7 M) 2 46 ft. (14.0 M) 3 34 ft. (10.4 M) 4 22 ft. ( 6.7 M) Table 5. ©WARNING! DO NOT USE PVC PIPE FOR FLUE EXHAUST VENT. FLUE EXHAUST VENT TEMPERATURES CAN BE IN EXCESS OF 400° F. FLUE EXHAUST VENT MUST BE CATEGORY I or CATEGORY III METAL VENT. Figure 15. 1 Note (*): Combustion Air Intake Duct Connection Kit (Part Number 461031) for all MasterTemp heater models can be purchased separately. See page 63 for parts list. NOTE Each 90-degree elbow reduces the maximum horizontal PVC air intake duct run by 12 feet and each 45-degree elbow in the PVC air intake duct run reduces the maximum run by 6 feet. See the Table 5 above for the maximum lengths using 90-degree elbows. Corrosive Vapors and Possible Causes Table 6. Area Likely Contaminants Chlorinated swimming pools and spas Pool or spa cleaning chemicals. Acids, such as hydrochloric or muriatic acid. New construction and remodel- Glues and cements, construction adhesives, paints, varnishes, and paint and varnish strippers. Waxes ing areas. and cleaners containing calcium or sodium chloride. Beauty parlors Permanent wave solutions, bleaches, aerosol cans containing chlorocarbons or fluorocarbons. Refrigeration plants or various industrial finishing and process- Refrigerants, acids, glues and cements, construction adhesives. ing plants Dry cleaning and laundry areas Bleaches, detergents, or laundry soaps containing chlorine. Waxes and cleaners containing chlorine, calcium or sodium chloride. ©CAUTION Chemicals should not be stored near the heater installation. Combustion air can be contaminated by corrosive chemica fumes which can void the warranty. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 25 VENT INSTALLATION — INDOOR INSTALLATION (US AND CANADA) (Category I) NOTE *: Vent must be at least eight (8) feet away from nearest vertical surface. Vents extending five (5) feet or Always vent the heater to the outdoors, see Note*. more above the roof must be braced or guyed. Consult your local code officials for detailed information. • Vent it vertically using Type `B" double wall vent connector pipe. Locate the heater so as to minimize the length of horizontal venting and the number of vent elbows required. Horizontal vent runs must slope up 1/4-in per foot (2cm/M) from the heater to allow exhaust condensate to drain and it is recommended to have a condensate drain as described in the venting installation instructions. VERTICAL VENTING - NEGATIVE PRESSURE (See Figures 16, 17 and 18) Vent the heater vertically in a negative pressure (positive draft) system in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Codes, and local codes. Type "B" Double -wall vent connector is recommended; however single -wall pipe is allowed by the National Fuel Gas Code in some circumstances. Consult your local code official for detailed information. Do not use a draft hood with this heater. To connect a negative pressure metal gas vent to the heater, order the appropriate Metal Flue Collar from the chart below: Metal Flue Collar Part No. 4 x 6" 77707-0076 4 x 8" 77707-0077 Table 6. Clean the Interior Surface Vent Body 4" x 8" Metal Flue Collar Vent Pipe i I Clean and RTV Combustion This Surface Chamber Flue Collar 1. See Table 7, on page 26 to determine allowable vent sizes for your heater. Figure 16. NOTICE: Table 7 is for installations in which the total lateral vent length (that is, the horizontal distance from the flue collar to the main vertical portion of the vent) is less than 1/2 the total vent height (the vertical distance from the flue collar to the vent termination) and which have three or less elbows in the system. For venting systems which do not meet these conditions, consult the National Fuel Gas Code, ANSI Z223.1 (U.S.), or the standards CSA B 149.1 and B 149.2 (Canada). Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 26 Section 3. Installation Instructions Read "VERTICAL VENTING - NEGATIVE PRESSURE" before using this table. Table 7. - Permitted Minimum and Maximum Vent Heights By Size and Heater Model Type "B" Double -Wall Vent with Type "B" Double -Wall Connector in Feet (Meters) Vent Model175 Model200 Model250 Model300 Model400 Height min./ Size Height min./max. Height min./max. Height min./max. Height min./max. max. 6 in. 6 ft. (1.8) /100 ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) 18 ft. (5.5) /100 ft. (30.5) 30 ft. (9) /100 ft. (30.5) Not Rec. 7 in. 6 ft. (1.8) /100 ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) 8 ft. (2.4) /100 ft. (30.5) 10 ft. (3) /100 ft. (30.5) 15 ft. (4.6) /100 ft. (30.5) 8 in. 6 ft. (1.8) /100 ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) 8 ft. (2.4) /100 ft. (30.5) 9 and 10 in. 6 ft. (1.8) /50 ft. (15.3) 6 ft. (1.8) /50 ft. (15.3) 6 ft. (1.8) /50 ft. (15.3) 6 ft. (30.) ft. (30.5) 6 ft. (1.8) /100 ft. (30.5) Type "B" Double -Wall Vent with Single -Wall Connector in Feet (Meters) Vent Model175 Model200 Model250 Model300 Model400 Height min./ Size Height min./max. Height min./max. Height min./max. Height min./max. max. 6 in. 6 ft. (1.8) /15 ft. (4.6) 6 ft. (1.8) /15 ft. (4.6) 6 ft. (1.8) /15 ft. (4.6) Not Rec. Not Rec. 7 in. 6 ft. (1.8) /8 ft. (2.4) 6 ft. (1.8) /8 ft. (2.4) 6 ft. (1.8) /8 ft. (2.4) 10 ft. (3) /20 ft. (6) 15 ft. (4.6) /50 ft. (15.3) 8 in. Not Rec. Not Rec. Not Rec. 6 ft. (1.8) /20 ft. 8 ft. (2.4) /20 (6) ft. (6) 9 in. Not Rec. Not Rec. Not Rec. Not Rec. 6 ft. (1.8) /6 ft. (1.8) 10 in. Not Rec. Not Rec. Not Rec. Not Rec. Not Rec. NOTE The allowable vent runs for each vent pipe diameter are different and can not be exceeded. Each 90-degree elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in the vent run reduces the maximum vent run by 6 feet. See Table 5 on page 24 for the maximum vent lengths using 90-degree and 45-degree elbows. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 27 2. Install the metal Flue Collar in the Vent Body of the heater (located under the outside vent cover). Fasten the metal Flue Collar to the Vent Body with two #10 sheet metal screws. Use high temperature silicone RTV to seal the Flue Collar to the Vent Body. Before connecting the metal Flue Collar to the Vent Body, wet a clean cloth or paper towel with isopropyl alcohol (rubbing alcohol) and vigorously wipe the socket of the Vent Body. Immediately wipe the cleaned surfaces dry with a clean cloth or paper towel. Repeat for the exterior of the 4" end of the metal Flue Collar. Attach the metal Flue Collar to the Vent Body using the RTV supplied with the kit, following the vent manufacturer's instructions (included with kit). 3. Attach the vent pipe to the metal Flue Collar with sheet -metal screws. Continue to next page. ©WARNING Risk of fire or asphyxiation if vent is not assembled according to manufacturer's instructions or if vent parts from different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one manufacturer may cause leaks or damage to vent. When assembling a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer's instructions, local code requirements, National Fuel Gas Code requirements (U.S.) or standards CSA B149.1 and B149.2 (Canada) carefully d ing assembly and installation. Rev. P 8/2020 -Min. 10 Ft.— 77: 6" Minimum Clearance to Combustible Materials Class B Double Wall Metal Vent Pi e p Metal Flue Bodt Collar Y Listed Termination Cap Storm Collar Flashing Fi restop Support Vertical Vent Pipe so adapter does not take weight of pipe. Figure 17. — Typical Metal Vent Pipe Installation - U.S. (Vertical — Negative Pressure) Approved • Termination Min. 2 Ft. Cap Min. 10 Ft. (3.3 M) Storm Collar Flashing 6" (15 cm) Minimum Clearance to Combustible Materials Double Wall Fires top t MASTERTEMP Pool and Spa Heater Installation and User's Guide 28 Section 3. Installation Instructions 4. Install vent pipe so that it can expand and contract freely as the temperature changes. Support the vent pipe according to applicable codes and the vent manufacturer's instructions. Pipe support must allow the vent pipe free movement out and back, from side to side, or up and down as necessary, without putting a strain on the heater or vent body. Slope horizontal pipe runs up from the heater at least 1/4" per foot (2cm per meter). Install Listed condensate drains at low points where condensate might collect. Plumb condensate drains to a drain through hard piping or high temperature tubing such as silicone rubber or EPDM rubber — DO NOT USE VINYL OR OTHER LOW TEMPERATURE TUBING. FOLLOW DRAIN MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. Use Listed fire stop for floor and ceiling penetrations. Use Listed thimble for wall penetrations. Use a Listed roof flashing, roof jack, or roof thimble for all roof penetrations. Do not fill the space around the vent (that is, the clear air space in the thimble or fire stop) with insulation. The roof opening must be located so that the vent is vertical. 6. Do not run the heater vent into a common vent with any other appliance. ©WARNING Fire Hazard. Do not vent the heater directly into a masonry chimney. Installation into a masonry chimneymu use a chimney liner and must meet the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA 13149.1, Natural Gas and Propane Installation Codes requirements and all local code requirements. ©WARNING Risk of fire, carbon monoxide poisoning, or asphyxiation. It is recommended to use a CO Monitor and Fire Alarm in MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 29 HORIZONTAL OR VERTICAL VENTING - POSITIVE PRESSURE (See Figures 19, 20, & 21) (Category Ill) Vent the heater either horizontally or vertically using an optional vent adapter of the 4-inch special gas approved Category III vent pipes. Install the vent pipe in accordance with local codes and the provisions of the National Fuel Gas Code, ANSI Z223.1 (U.S.), or the standards CSA B 149.1, Natural Gas and Propane Installation Codes (Canada), and the vent manufacturer's instructions. Do not use a draft hood with this heater. Install the vent according to the vent manufacturer's detailed instructions. Note: Maintain clearance between the vent pipe and combustible surfaces according to the vent manufacturer's instructions and code requirements. Do not place any insulating materials around the vent or inside the requirecl. clear air space surrouncling the vent. See lable I I tor maximum permissible vent eng s. NOTE The allowable vent runs for each vent pipe diameter are different and can not be exceeded. Each 90' elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in the vent run reduces the maximum vent run by 6 ft. See the Table 8 below for the maximum vent lengths using 90' elbows The MasterTemp heater is a "Category III" appliance (which Table 8. requires a four (4) inch special gas approved "Category III" vent pipe) and is a forced -draft pool and spa heater which uses positive pressure to push flue gases through the vent pipe to the outside. Flue gases under positive pressure may escape into the dwelling with any cracks or loose joints in the vent pipe, or improper vent installation. The vent pipe must be of a sealed - seam construction, such as those listed for use with "Category III Appliances", and for operating temperatures less than 400°F (204°C). Vent pipe construction will be of UL 1738 approved non -corrosive material, such as stainless steel. A condensate trap may be needed. The use of "Approved" thimbles, roof jacks and/or side vent terminals are required; and the proper clearances to combustible materials must be maintained in accordance with type of vent pipe employed —in the absence of a clearance recommendation by the vent pipe manufacturer, the requirements of the Uniform Mechanical Code should be met. Seepage 21, for heater ventilation air requirements. It is recommended that vent runs over 18 feet may need to be insulated to reduce condensation related problems and/or the use of a condensate trap in the vent run close to the heater may be necessary in certain installations such as cold climates. Horizontal vents 3' (1M) or 4 in. Special Gas Vent (Vertical or Horizotal)* No. of 90° Elbows Maximum Length in Feet (M) 0 70 ft. (21.3M) 1 58 ft. (17.7M) 2 46 ft. (14.OM) 3 34 ft. (10.4M) 4 22 ft. (6.7M) *Minimum vent length is one foot (.34M), or in accordance with vent manufacturer's instruction, and local and national codes. Horizontal vents 3'(1 M) or less in length do not re- quire a condensate tee, but must slope down toward the out- let at 1/4" to the foot (2cm/M) to allow condensate to drain. less in length do not require a condensate tee. The MasterTemp heater is suitable for through -the -wall venting. AcAunoN Do NOT combine exhaust vent pipes to a common exhaust vent in multiple unit installations. Run separate vent pipes. CONNECTING SPECIAL METALIC GAS VENT TO THE HEATER 1. ORDER AN OPTIONAL APPLIANCE ADAPTER HIT: (Pentair offers optional appliance adapter kits, call Customer Service at (800) 831-7133 for more information): Part No. 77707-0086 for Saf-T Vent® or Saf-T Vent® CI. Part No. 77707-0087 for Z-Vent. 2. Remove the outside vent cover. Install the Appliance Adapter in the Vent Body of the heater (located under the outside Vent Cover). Before connecting the Appliance Adapter to the Vent Body, wet a clean cloth or paper towel with isopropyl alcohol (rubbing alcohol) and vigorously wipe the socket of the Vent Body. Immediately wipe the cleaned surfaces dry with a clean cloth or paper towel. Repeat for the exterior of the heater end of the Appliance Adapter. Attach the appliance adapter to the vent body using the adhesive specified by the vent manufacturer, following the vent manufacturer's instructions. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 30 Section 3. Installation Instructions Risk of carbon monoxide poisoning if adapter is improperly attached. Mechanical connections (such as screws) can cause cracking and leaks in the adapter. DO NOT drill holes or use screws to connect the appliance adapter to the heater vent body. Attach with manufacturer's specified adhesive. Risk of fire or asphyxiation if vent is not assembled according to manufacturer's instructions or if vent parts from different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one manufacturer may cause leaks or damage to vent. When installing a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer's instructions and local and National Fuel Gas Code (U.S.) or CSA B149.1, Natural Gas and Propane Installation Codes (Canada) requirements carefully during assembly and installation. 4. Install vent pipe so that it can expand and contract freely as the temperature changes. Support the vent pipe according to applicable codes and vent manufacturer's instructions. Pipe support must allow the vent pipe free movement out and back, from side to side, or up and down as necessary, without putting a strain on the heater or vent body. It is recommended to slope the horizontal pipe runs up from the heater at least 1/4" per foot (2cm/M). Install "Approved" condensate drains at low points where condensate might I ►Q Vent Cap and ~— Chimney or Gas Vent Riser Furnished by Installer , collect. Plumb condensate drains to a drain through hard piping or high -temperature tubing such as silicone rubber or EPDM rubber — do not use vinyl or other low temperature tubing. Follow drain manufacturer's installation instructions. side Wall Vent Use an "Approved" firestop for floor and ceiling penetrations. Use an "Approved" thimble for wall penetrations. Use an "Approved" roof flashing, roof jack, or roof thimble for all roof penetrations. Do not fill the space around the vent (that is, the clear air space in the thimble or firestop) with insulation. The roof opening must be located so that the vent is vertical. Vent Termination — Vertical (See Figures 19 and 20), for height of vent termination above the roof. Use an "Approved" vent terminal specified by local and national codes and your manufacturer's instructions. A roof termination must be vertical. In Canada, the Vent Cap location shall have a minimum clearance of 4 feet (1.2M) horizontally from electric meters, gas meters, regulators, and relief openings. �' Q Vent Cap and ~ Chimney or Gas Vent Riser Furnis' by Installer Make sure entire installation is sealed according to approved f standard. side Wall Vent Continue on next page. Outlet Air Opening Inlet Air Opening Figure 19/20. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 31 4' Min. Vent Termination I I t4' Min. - I 11�- 1 Minimum Gas Meter above snow or Forced Air 7 finished grade Inlet (whichever is 3' Minimum clearance if higher) horizontal distance to exhaust opening is less than 10 feet. 8. Vent Termination — Horizontal The terminal must be located (U.S. See Figure 21): 4' Min. Vent Termination 1' Min. t Max. 12" Min. 3" Vent I I Termination At least 7' above grade adjacent to public walkways Figure 21. • at least 3" and at most 12" out from the wall (see Figure 22), following the vent manufacturer's instructions • at least 12" above finished grade or the normally expected snow accumulation level, whichever is higher • at least 4 feet below or horizontally from, or 1 foot above, any doors or windows or gravity air inlet to a building • at least 3 feet above any forced air inlet located within 10 feet • at least 4 feet horizontally from electric meters, gas meters, regulators and relief equipment • at least 7 feet above grade adjacent to walkways or similar traffic areas The terminal must be located (Canada — See Figure 21): • at least 10 feet (3.3M) from any opening into a building • at least 12" (.3M) above finished grade or the normally expected snow accumulation level, whichever is higher • at least 4 feet (1.2M) horizontally from electric meters, gas meters, regulators and relief equipment • at least 7 feet (2.1M) above grade adjacent to walkways Metal l or similar traffic areas Body Allow at least three feet (1M) vertical clearance over vent termination when terminating under an overhang. Avoid corners or alcoves where snow or wind could have an effect. Exhaust may affect shrubbery and some building materials. Keep shrubbery away from termination. To prevent staining or deterioration, sealing or shielding exposed surfaces may be required. Metal Special Support Gas Vent weight requires of pipe Appliance Listed Adapter Condensate Terminal Tee � P Slope at least 1/4" per foot Condensate (2 cm per Meter) drain w/Trap down towards 3" (7.6 cm) Min., (Optional) condensate drain 12' (30.5 cm) Max. Clearance Figure 22. © WARNING Fire Hazard. Do not run the heater vent into a common vent with any other appliance. Do not run the Special Gas Vent into, through, or within any active vent such as a factory built or masonry chimney. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 32 Section 3. Installation Instructions Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Exhaust venting to the outdoors is required for all outdoor shelter installations. AwAgNiNG Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). Consult local codes and fire protection authorities about specific installation restrictions. The heater is design certified by CSA International for installation on combustible flooring; in alcoves; basements; in closet or utility rooms (in the U.S.). GARAGE OR UTILITY ROOM INSTALLATION In Canada, the heater must be installed in a room that is not normally occupied and has no openings directly to occupied areas. Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid storage. Gasoline fumes are heavier than air and will settle to floor level in closed spaces. Gasoline fumes and spilled gasoline or other volatile liquids (such as some paints and varnishes) will travel across the floor and can be ignited by a gas appliance. In any utility room or residential garage installation, install the heater with the base at least 18 inches (.5M) above the floor, see Figure 23. In a garage, install a rail or wall to protect the heater from physical damage by a moving vehicle. Provide an adequate ventilation air supply (See Table 4, page 23). Choose a location that will avoid contamination by chemical fumes. NOTICE: Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty (See Table 5, page 24). CAUTION A Propane (LPG) fired heater must not be installed ina garage in Massachusetts, by order of the Massachusetts State Fire Marshal. For more information, call the Massachusetts State Fire Marshal's office. Leave 6 in. (15 cm) of clear space between heater and combustible surface. RAISE AT LEAST t 18 in. (46 cm) above floor 18 in. to avoid flammable vapors I Leave 3 ft. (1 m) or more of clearance above heater Figure 23. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 33 CONTROL PANEL POSITIONING On an outdoor shelter installation, the exhaust discharges into a vent pipe. Orient the heater so that the vent pipe does not interfere with adjustment of the operating controls. The control panel located on the top panel can be rotated to any of the three sides of the heater for easy access, see Figure 24. 1. Remove the bolts from the door panels. Remove both door access panels. 2. Remove the four corner wing nuts that secure the top panel. Lift the top panel upward to remove the top panel. Rotate the top panel to the desired position located at 90' angles. Note that the control panel mustNOT be located on the side where the vent is located. Top Panel 4. Replace the top panel down onto the side panels. Be sure that there are no Access Panel wires caught under the panel. Figure 24. 5. Secure the top panel using the four corner wing nuts. 6. Reattach the door access panels. FINAL INSTALLATION CHECK Check that horizontal vent pipe runs slope uniformly at least 1/4" per foot (2cm per meter) to condensate drain(s). No sags, no dips, no high or low spots. See Figure 25. Check that vent is supported at elbows, tees, and horizontal and vertical runs according to manufacturer's instructions and code requirements. Check that vent supports and wall and ceiling penetrations allow free movements up, down, and sideways without putting any strains on the heater or vent body. Check for at least six inch (15cm) free air clearance between the heater vent pipe and combustible materials. Check that all joints are completely together and sealed. Figure 25. Door Access Panel For Heater mounting bolts and clamps, purchase separately Bolt Down Bracket Kit, Part No. 460738. Lead, I Anchor to In Florida, building codes require that the heater be anchored to the equipment pad or platform to withstand high wind pressures created during hurricanes. A Bolt Down Bracket Kit, P/N 460738, is available with anchor clamps designed to hold the unit to the equipment pad in high wind conditions. Installation of the anchor clamps are recommended in all installations and are required in Florida, (See Florida Building Code 301.13). ELECTRICAL CONNECTIONS Electrical Rating: 60 Hz 120 / 240 Volts AC, single phase: Enclose the incoming AC power line to the heater in an approved flexible conduit connected directly to the junction box on the inside of the access door panel. Line volt- age field wiring should be 14 gauge, with a circuit capacity of 15 Amps. Note: The heater operating AMP draw is about 5 AMPS at 120 VAC and 2.5 AMPS at 240 VAC. A 15 AMP circuit capacity is required for the inrush current at startup. IMPORTANT NOTICE. FOR HEATER BONDING, see page 35 ©CAUTION This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC. Continue to next page. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 34 Section 3. Installation Instructions ELECTRICAL CONNECTIONS (CONTINUED) NOTE • Before making any electrical connections to the power supply, remove the access door panels, open the control box and plug in the correct plug (120 VAC or 240 VAC). See plugs below. ©CAUTION The heater ships from the Factory with the 240 VAC plug installed. Installing the 120V plug and then connecting the heater to 240V line current will immediately destroy the transformer, control board and ignition control module, and will void warranty. If you install the 240V plug and connect the heater to 120 VAC line current, the heater will not operate. If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG, 600V, 1050 C. U.L. approved AWM low enerqv stranded) copper wire or it's equivalent. Please read the boxes headed "IMPORTANT! READ ME FIRST!" on page 42 and 49 before proceeding. 1. All wiring must be in accordance with all applicable codes. 2. The heater, when installed, must be electrically grounded and bonded in accordance with local codes or, in the absence of local codes, with the National Electrical Code or the Canadian Electrical Code (as applicable). A bonding lug is provided on the outside of the panel under the vent for this purpose. 3. Electrical power circuits to the pool heater must follow local codes and National Electrical Code or Canadian Electrical Code (as applicable). 4. All wiring between the heater and devices not attached to it, or between separate devices which are installed in the field, must be "Type T" wire rated for 35°C rise. 5. All line voltage wiring shall be enclosed in approved flexible conduit, and shall be securely attached to the field wiring box located inside the access door panel. The conduit or cable connector at the field wiring box should contain an insulating bushing or its equivalent to prevent abrasion of the wires as they enter the box. 6. The filter pump should run continuously when the heater is on, and for at least 5 minutes after the heater turns off. Any switches in the pump circuit (including circuit breakers) that can disconnect the pump must also disconnect the heater. Do not wire single -pole switches, including protective devices, into a grounded line. The heater is not sensitive to polarity. Connect the Ll of the power supply to the black wire, the L2 or neutral lead to the red wire, and the ground wire to the green wire. A time clock controlling the filter pump should have a low -voltage Fireman's Switch that switches off the heater at least 15 minutes before shutting off the pump. Always use crimp type connectors when con- necting two wires. AC VOLTAGE SELECT PLUGS: (120 VAC or 240 VAC) Figure 26. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 35 HEATER BONDING ©WARNING To reduce voltage gradients in the pool area, the heater and the pool system equipment must be electrically grounded and "bonded" together. Con- nect a solid copper conductor (8 AWG or larger) to the heater "bonding" terminal lug provided on the ex- haust side of the heater. See Figure 27. Not properly "bonding" and grounding the heater increases the risk of electrical shock and can cause damage and electrolysis to the heat exchanger. All wiring must be in accordance with all applicable codes. The heater, when installed, must be electrically grounded and "bonded" in accordance with local codes or, in the absence of local codes, with the National Electrical Code or the Canadian Electrical Code (as applicable). HEATER BONDING CONNECTOR O❑ EXHAUST SIDE ELECTRICAL CONDUIT PORT Figure 27. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 36 Section 3. Installation Instructions REMOTE CONTROL CONNECTIONS 1. Switch off power to heater at main circuit breaker panel. 2. Unbolt and remove the access door panels. 3. Open control box cover (see Figure 28). 4a. To connect a 2-Wire Control (such as IntelliTouch® or EasyTouch® Control Systems) or a timer: - Remove the factory installed jumper from the Fireman's Switch terminals. - Connect wires between the Fireman's Switch terminals on the heater and the relay. Connect wires from the controller or timer to the Fireman's Switch. Controller, timer or relay should be sized to handle 24VAC at 0.5 Amp (because it will be completing the 24VAC control board circuit on the heater as shown in Figure 28). DO NOT apply line voltage to the Fireman's Switch terminals. Use 18 gauge wire with a minimum 3/64" (1.2mm) thick insulation rated for a temperature rise of at least 105°C. - Knock -outs are provided to route the wires through the bottom of the control box and past the junction box. 4b. To connect a 3-Wire Control: - Connect wires between the control board terminals on the heater and the external relays, as shown in Figure 34. Use at least 2 relays per heater, to allow for an "OFF setting" on each heater mode. Select relays that can handle logic level switching. DO NOT apply line voltage to control board terminals. - Move jumper (as shown on Figure 34) to enable external control and to disable the heater membrane pad's "Pool /Spa button (the "HEATER OFF") button on the control panel remains functional). - Knock -outs are provided to route the wires through the bottom and the top of the control box and past the junction box. 5. Close control box cover. 6. Re -install the access door panels. To control heaters that are operated in parallel, connect wiring at same locations on heater as 2-Wire or 3-Wire Control. It is imperative that each control circuit is isolated from the other control circuits, to avoid that current will flow from one heater to another through the control circuits. NOTICE: The fuse for the Fireman's Switch is a 1.25 Amp 11/4 x %4" fast blow fuse. Figure 29. TRANS Figure 28. � L *k \ J =� J6 2 r OPERATING CONTROL • • MEMBRANEPAD • • y ENABLE TOGGLE CONNECTION • 01 DISABLE TOGGLE CD TERMINAL BOARD Is F, Y Y Y Y f 124VAC Jw, �U) W L� z W ~ ,NS w —7/ R� Time Clock or Remote (Purchase Separately — Supplies Power to Circulator Pump) Fireman's Switch Completes the heater ♦� 24 Volt AC Control Board Circuit. * DO NOT connect this circuit to Line Voltage! MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 37 Connecting the MasterTemp° Heater to the IntelliCenter TM Control System Load Center via RS-485 For remote control and monitoring, the MasterTemp heater can be connected via the heater's RS-485 COM port to the IntelliCenter Control System COM port. The heater can be wired to the IntelliCenter Control System via a RS-485 connection. Up to 16 heaters can be connected. The default address of a heater is 1. If additional heaters are connected, each heater must have its own address. The address range is 1 to 16. The address for each heater is set from the heater's front LCD panel menus. When a heater is being controlled via the RS-485 interface: • The heater front panel buttons are inactive. Press a panel button to turn on the LCD display. "RS485 Control" is displayed. • Heater Alarms/Errors are displayed on IntelliCenter's control panel(s) Status Home screen. Accessing the MasterTemp° Heater RS-485 COM Port To access the MasterTemp heater control panel RS-485 COM port terminal, the RS-485 cable must be routed through the hole in the heater's side panel. To route the RS-485 cable through the heater's panel to the control panel circuit board: 1. Remove the four corner wing nuts that secure the top panel. Lift the top panel upward to remove the top panel. Note: If needed, remove the wires from the control board if the top is removed completely. See Figure 31. 2. Locate the small hole in the exhaust panel, for the RS-485 cable. Use an appropriate size drill bit for the flexible conduit or strain relief to be used in the exhaust panel to drill a hole for the RS-485 wires. See Figure 32. 3. Install a flexible conduit or a strain relief and securely attach to the heater panel. Note: The conduit or cable connector should contain an insulating bushing or its equivalent to prevent abrasion of the RS 485 wires as it enters the exhaust panel. 4. Strip back the outer jacket four inches of the cable. Strip back each conductor 1/4-inch. 5. Insert the RS-485 cable (from the Load Center or Power Center) through the flexible conduit or a strain relief into the exhaust panel hole and securely attach to the heater panel. 6. Once the cable is inside the heater, route the RS-485wires under exhaust. Note: Do not let the wires contact the exhaust. 7. Using cable ties, secure to the RS-485 cable to the main wire harness that connects to heater's control panel circuit board. 8. Insert the three RS-485 wires (Pin 1-BLACK, 2-GRN, 3-YEL) into the screw terminal. Secure the conductors with the screws. For wiring details, refer to the pin configuration on next page. 9. Heater Control Panel COM Port (J4): Insert the RS-485 connector onto the heater's control panel RS-485 COM Port screw terminal. Note Pin 1 is located on the left side of the terminal connector. 10. Replace the top panel onto the heater side panels. Be sure that there are no wires caught under the panel. Secure the top panel using the four corner wing nuts. 11. Continue with "Connecting the RS-485 Cable from the Heater to the Load Center" on next paage. Water Pressure Switch_ Drill an appropriate size hole for the flexible conduit or strain relief to be used. to secure the RS-485 wires. Figure 32. Figure 31. MasterTemp Heater (Exhaust Side) Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 38 Section 3. Installation Instructions Connecting the RS-485 Cable from the Heater to the Load Center To connect the MasterTemp heater to the load center: AWARNING BEFORE REMOVING THE HIGH VOLTAGE COVER PANEL FROM THE LOAD CENTER OR POWER CENTER ENCLOSURE SWITCH OFF T POWER AT THE HOUSE MAIN CIRCUIT BREAKER BOX. 1. Switch OFF AC power to the enclosure at the main house panel circuit breaker. 2. Unlatch the front door latch and open the front door. Remove the two retaining screws from the High Voltage Cover Panel and remove the panel. See Figure 30. Loosen the two retaining screws securing from the top edge of the Outdoor Control Panel. Fold down the Outdoor Control Panel to access the circuit board sockets connectors for the electrical connections. Retaining screws Front door ® °O00 ®® 3 LOW VOLTAGE High Voltage Cover Panel slotE RACEWAY Figure 30. Circuit board and low voltage compartment High Voltage Cover Panel Tabs (3) Note: Use a 22AWG four conductor low voltage RS-485 cable to connect to the MasterTemp heater to the IntelliCenter Control System Load Center. 4. Run the RS-485 cable from the heater's control board RS-485 COM port terminal connector to the Load Center or Power Center. See wiring connection Figure 33 on next page. 5. Insert the cable into the one of the plastic grommet fittings, located on the lower left side of the enclosure and pull the cable up through the low voltage to the circuit board, as shown below. 6. Strip back the outer jacket four inches. Strip back each conductor'/4-inch. 7. IntelliCenter Control System COM Port (J4 or J5): Insert the conductors into the COM Port screw terminals located on the top of the IntelliCenter Control System circuit board (see diagram below). Secure the conductors with the screws. For wiring details, refer to the pin configuration shown below. Note: Multiple conductors may be inserted into a single screw terminal. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 39 Connecting the RS-485 Cable from the Heater to the Load Center (Continued) )ptional Personality Card b1e:Ogianel Personality Cab must lug dirsdlyi,Ao%m Man CwNol Beaty am a,vi R1°D• cna FILTER ® HEATER PUMP ® J2 CIRCUIT AU%ILRRYCMCUITS td nuu rsm nua, avz •uu ssro vuvan vvea spun wrn R°D 24VAC i5P MAIN CONTROL BOARD 522079) °P1 TB~ o NDte: COM PORT A& B 14 VDC, 2.OA Max. RETURN INTAKEp J Z y Wco CDmbinad VLVD VLVCW WO COMPORTRB465•B(J4 W KJ ® ® ® ® ® ® llllw al e4 e3 e2 e iS4 Remote (J2) WATERSOLARAIR S4eRmote COM PORT (J75) (J8) R5465•A (J5) 1 To heater COMMUNICATION PORTS A 8t B 14 VDC, 2.OA Max. Combined. Control Panel Connecting IntelliFlo® Pump to IntelliCenterTM Control System COM PORT: Strip 1/4" insulation from the green and yellow wire conductors. RS-485 COM port p • Connect the Green wire to pin 2 on Connector J4 or A screw terminal • Connect the Yellow wire to pin 3 on ConnectorJ4 or J5. Note: Multiple wires may be inserted into a single terminal. TO HEATER Optional: COM PORT expansion module (P/N 520818) with 3 extra CONTROL PANEL- - - - COM PORTS up to 2 modules can be installed. RS-485 COM PORT MasterTemp COM Pport Control Panel Screw Terminal Figure 33. Heater to IntelliCenter wires pin assignment • 1 2 3 4 MasterTemp Heater COM Port screw terminal connector IntelliCenter Control System COM Port (J4 or J5) NOT USED I NOT USED 3 (YELLOW) 3 (YELLOW) 2 (GREEN) 2 (GREEN) 1 (BLACK) 1 (BLACK) 8. Reinstall the High Voltage Panel: Insert the panel's three tabs into the lower slots on the enclosure. 9. Secure the panel with the two (2) retaining screws. Close the front door and secure with the latch. See Figure 30 on page 38. 10. SWITCH ON AC power to the IntelliCenter Control System Load Center. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 40 Section 3. Installation Instructions MASTERTEMP HEATER WIRING DIAGRAM (3-WIRE SYSTEM) AGS Switch Air Flow Switch Stack Flue Sensor Extra Switch 1 Gas Valve Hi -Limit Switch Pressure Switch 1L � 1 W 0 1 YI Y I I R I I I IoIRPR L External Control Interface Circuit Disabled, Heater Control Panel Enabled CONNECTION DIAGRAM 31 > N 01 TO 0 OPERATING CONTROL BYPASS VALVE ® ]MPl 'ALINE BKR �y —COMMON LINE II POOL LINE J MP 1 External Control Interface DISABLE 3-WIRE CONTROL 1 10 Fj JMP1 ,l ENABLE 3-WIRE CONTROL 1 0 When 3-Wire Control is enabled, the POOUSPA button on the heater's control panel is disabled Plug —12 pin 120V —Black 240V — Red N1 JUNCTION BOX Line 1 }LBK I Line 2 >i R — Ground �� GZ GND Y/R Y/BL Y/o Y/ W Y Y, Y• Y, Y, terminal while the heater is connected to line power will immediately destroy the control board and void the warranty. MASTERTEMP Pool and Spa Heater Installation and User's Guide Figure 34. Rev. P 8/2020 Section 3. Installation Instructions 41 MASTERTEMP HEATER ELECTRICAL SCHEMATIC LADDER DIA- LADDER DIAGRAM L1 — 120/240 - L2 VAC IGNITER L1 S1 S2 L2 --LFlj LF2 BLOWER GND 120/240 VAC CLASS II TRANSFORMER 24 VAC OPERATING CONTROL 24 VAC 24 VAC GN AIR FLOW SWITCH -10 24V LOGIC TH WATER PRESS, HI -LIMIT SWITCH SWITCH COM NO AGS SWITCH VAL GAS VALVE THERMISTOR STACK FLUE SENSOR SENSOR 1-2- BYPASS VALVE NOTES: 1.) Li L2 F1 F2 S1 24 VAC S2 GND IND VAL TH ARE CONNECTED ON THE IGNITION MODULE. 2.) A PIN AND SOCKET CONNECTOR. 3.) IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, THEY MUST BE REPLACED WITH TYPE 105°C WIRE OR ITS EQUIVALENT. 4.) EXTERNAL VALVE THAT NEEDS TO BE INSTALLED. Figure 35. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 42 Section 3. Installation Instructions BASIC SYSTEM OPERATION Start pump, make sure the pump is running and is primed, to close the water pressure switch and supply power to heater. Be sure the pool and/or spa is properly filled with water. Follow the Lighting/Operating instructions below. MASTERTEMP HEATER HSI ELECTRONIC IGNITION LIGHTING/OPERATION FOR YOUR SAFETY: READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not attempt to light the heater if you suspect a gas leak. Lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage. START-UP AND OPERATION START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE CONTROL BOX. BEFORE START-UP A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burners. Do not try to light the burners by hand. B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS — Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. — Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the Fire Department. C. Use only your hand to turn the gas control on or off. Never use tools. If you cannot change the ON/OFF setting by hand, don't try to repair it, call a qualified service technician. Forced or attempted repair may result in a fire or explosion. D. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. E. Do not operate the pool heater unless the pool or spa is properly filled with water. F. Before operating the appliance for the first time or after it has been off for an extended time, perform the following checklist: I . Remove debris or other articles from inside the heater and the area around the heater and its exhaust vent. Make sure the ventilation openings are clear of debris or obstruction. For installations in an enclosed space, make sure openings for combustion and ventilation air are unobstructed. 2. Keep heater area clear and free from combustibles, flammable liquids and chemicals. 3. Check that all water connections are tight. 4. Water must be flowing through the heater during operation. Make sure thatpool/spa is filled with water and have pump operating. Check that water flow is unobstructed from the appliance. When operating for the first time or after an extended shut -down, run filter pump for several minutes to clear all air from the system. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 4. Operation Instructions 43 OPERATING INSTRUCTIONS 1. STOP! Read the safety information on (page 42). 2. Set both pool and spa set points to the lowest settings. 3. Turn off all electric power to the appliance. 4. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Remove the access door panels by unfastening the four screws located on each s door, then lift up and out from the bottom of the panel to remove. If necessary, the screws may be used as handles, see Figure 36. 6. Toggle -Style Valve: Pull toggle toward you to turn gas off , see Figure 37. 7. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow `B" in the "Before Start-up" instructions (page 42). If you don't smell gas, go to the next step. 8. Push the toggle switch away from you to switch the gas on. 9. Replace the Door Access Panels. All panels must be in place when operating the heater. 10. Set 3-way valves on inlet and outlet to pool or spa, as appropriate. 11. Turn on all electric power to the appliance. 12. Toggle between Pool or Spa mode on the operating control. 13. Set the thermostat to desired setting (NOTICE: Setpoint must be above actual water temperature or burner will not fire). See CONTROL PANEL on page 46. YOU ARE HE Gas control is shown OFF. Push toggle switch away from you to switch ON. Figure 37. 14. The blower should come on immediately, and after about 20 seconds, the burner should fire. When operating for the first time, the burner may not fire on the first try because of air in the gas line. If it does not fire at first, push the OFF switch, wait five minutes, and again push the POOL or SPA ON switch. The burner should fire after about 20 seconds. You may have to repeat this until all of the air has cleared the gas line. 15. The burner should fire until the pool/spa temperature reaches the desired temperature set on the thermostat. The blower will continue to run for about 45 seconds after the burner shuts off. If any of the safety interlocks should open during burner operation, the burner shuts off immediately, but the blower continues to run for about 45 seconds. Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. 16. If the appliance will not operate, follow the instructions below "TO TURN OFF GAS TO THE APPLIANCE", and call your service technician or gas supplier. TO TURN OFF GAS TO APPLIANCE 1. Press the OFF button on operating control. 2. Switch off all electric power to the unit. 3. Remove the access door panels, see Figure 36. 4. Toggle -Style Valve: Pull toggle toward you to turn gas off, see Figure 37. 5. Replace the Access Door Panels. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 44 Section 3. Installation Instructions SAFETY CONTROLS AIR FLOW SWITCH (AFS) The air flow switch, (see Figure 38), is a safety device used to insure that the combustion air blower (fan) is operating and has been designed to monitor the vacuum (negative) pressure within the blower housing. The air flow switch is factory set and is connected upstream of the ignition module. The ignition module does not operate unless the air pressure switch and all safety switches are closed. WATER PRESSURE SWITCH ©WARNING Hazardous pressure. Do not bypass the Water Pressure Switch or render it inoperable. The water pressure switch, (see Figure 38). If the water flow is restricted, the water pressure switch may prevent the burner from firing and cause the "Service System" light to go on. If the light remains on after the filter has been serviced, have a qualified service technician check the system. For deck -level heater installations, the Water Pressure Switch is factory set at 3.00 psi (20.6 kPa). NOTE: SEE, BELOW POOL LEVEL INSTALLATION INSTRUCTIONS ON PAGE 15. If the pressure switch is one feet (.3M) below or above the pool water level, reset the switch so that it is open when the pump is off and closed when the pump is running. Turn the star -wheel on the switch clockwise ( t"'++ ) to raise setting (heater below the pool) and counterclockwise (("N ) to lower the setting (heater above the pool — see Figure 40. Test the switch after resetting. NOTICE: When the heater is mounted more than five feet (1.5M) above or four feet (1.2M) below the deck level, a Pressure Switch is no longer adequate. A Flow Switch must be installed instead. Turn star wheel clockwise to raise NOTICE: Heater operation with incorrect pressure set point pressure switch is more li than 4 feet (1.2M) below water level Pressure Switch setting may cause operation with no water flow. Operation of the heater without sufficient water flow may severely damage it. HIGH LIMITS A "High Limit", is a safety device that opens the electrical circuit and shuts off the heater based on a water temperature set point within the "High Limit Device". The MasterTemp heater series of heaters contains two (2) high limit devices which are located on the main inlet / outlet header. Turn sta pressure than 5 fE 0000� Air Flow Switch Figure 38. Figure 39. 'heel Figure 40. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 3. Installation Instructions 45 SAFETY CONTROLS, (cont'd.) OPERATION OF IGNITION MODULE The Ignition Module, (see Figure 41), is microprocessor based and operates on 24VAC supplied by the transformer. The control utilizes a microprocessor to continually and safely monitor, analyze, and control the proper operation of the gas flame holder. The module with the presence of the flame sensor, using flame rectification, allows the heater to operate. ©WARNING RISK OF EXPLOSION OR FIRE CAUSING BURNS OR DEATH IF SAFETY INTERLOCKS ARE DISABLED. DO NOT attempt to operate heater when The ERR HLS, ERRAFS, ERR IGN, ERRAGS, ERR SFS, E01, E05, E06,126 messages on the LCD indicates a fault in the heater or its controls. If any of these messages are displayed, shut down the heater (See "TO TURN OFF GAS TO THE APPLIANCE" on page 43), and have a qualified service technician check the system. Diagnostic errors are displayed on the control panel LCD: PS, HLS, SFS, AFS, AGS, IGN, or NONE. See Troubleshooting (pages 52-54) Flame Current Check Point an- — F1 F2 R FC* I A CAT. NO. 35-.2948 013 RITA2111 7iAGNOSTIC INDICATOR AUTOMATIC IGNITION SYSTEM _ �U MODE PRE -PURGE: 0 SEC. CONTROL - AIR FLOW FAULT INTERPURGE: 16 SEC. IGNITION: 7 SEC. - rLAME NO CALL FOR HEAT POSTPURGE: 60 SEC. HEAT UP', 20 SEC :^u:IITION LOCKOUT INPUT: 24 VAC. 60160 Hz, 300 mA V.EN(F:AME VALVE: 24 VAC.20 A MAX, GOCOFLAME �.� INDUCER: 1201240 VAC, 3.0 A 114 HP C F IGNITOR: 120 VAC, 6.0 A MAX. EN296 ` ` 111E IGNITOR INPUT. 120 VAC or 240 VAC, 60160 NZ. Diagnostic Indicator CAUTION: HI VOLTAGE - DISCONNECT WIRING BEFORE SERVICING AMBIENT: 401 F to-176'F ANSI Z21.20 CANICSA C22.2 No. 1S"89 (See table below) Figure 41. Table 7. Diagnostic Indicator Displayed Message Description UUN I KUL FAULI uispiays Message on Automation System AIR FLOW FAULT Displays Message on Automation System FLAME NO CALL FOR HEATDisplays Message on Automation System IGNITION LOCKOUT Displays Message on Automation System WEAK FLAME Displays Message on Automation System and viewed on Heater menu GOOD FLAME Displays Message on Automation System and viewed on Heater menu ERROR PS MESSAGE • The ERR PS message on the LCD indicates that there is insufficient water flow to the heater. If the pump is operating, this usually indicates that the filter and/or skimmers should be cleaned (some filters may require back -washing). If the message remains on after the filter/skimmers have been serviced, the system should be checked by a qualified service technician. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 46 Section 4. Operation Instructions CONTROL PANEL Control Panel Description LCD Display: The LCD displays two lines of text. During normal heater operation the current pool or spa water temperature is shown on line 1 of the display. The heater set point for the pool or spa is shown on line 2 of the display. The display will turn off after two (2) minutes of inactivity on the keypad. When the display is off due to inactivity, pressing any button will turn it back on. POOL/SPA: Toggles between POOL and SPA mode: Displays the selected pool or spa body of water actual temperature and set point. HEATER OFF: Press this button to put the heater into IDLE/OFF mode. The LCD will display HEATER OFF. Heater ON Red LED Indicator Pool/Spa LCDTemperature Toggle Button Display Toggle switch displays Heater/Off Menu/Back Temperature Select Controls Buttons Up/Down Figure 42. Heater Control Panel UP Arrow Button: Increase heater temperature set point. Scroll through menu items and change settings. DOWN Arrow Button: Decrease heater temperature set point. Scroll through menu items and change settings. SELECT. Select current menu item or save menu item settings. MENU/BACK: Enter menu items. Press Down to scroll through menu item. Press Menu/Back to return to main screen. HEATING (LED): Solid Red LED on indicates the heater currently heating. LED Off: Heater is not active. Note: During the heater ignition process, this LED blinks. Menu Navigation Press MENU/BACK displays POOL MAX. Use the DOWN or UP button to scroll through each of the highlighted menu items. 2. Press SELECT to access the highlighted item. Press UP/DOWN to change or view the highlighted item. 3. Press SELECT to save, exit the setting and return to the menu items. Note: To exit the menu without saving and return to the main screen, press MENU/BACK two times. Operating the Heater The heater comes factory set at 78°F for the pool mode and 100°F for the spa mode. Using the up and down arrows, you can set the thermostats to a minimum temperature of 650 E, or a maximum of 1040 E Heating the Pool or Spa (Press the HEATER OFF button to turn OFF the heater). Press POOL/SPA to select either Pool or Spa. The display shows the current set point and water temperature. Press Up/Down to increase or decrease water set point temperature. If the current water temperature is below the Set point water temperature, the heater will begin heating. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 4. Operation Instructions 47 Menu POOL MAX (65°F-104°F): The maximum heater operating temperature for the pool. SPA MAX (65°F-104°F): The maximum heater operating temperature for the spa. UNITS: Select F (Fahrenheit) or C (Celsius) to display change the display of the heat settings. Select US or Metric units. HISTORY. Use Up/Down button to scroll through the last five heater errors. CYCLES: Number of heater on/off cycles. RUNTIME: Total number of hours the heater has spent heating the water. SITS TEMP: Displays the current Stack Flue Sensor temperature. FLAME: Displays the current flame sensor status (Normal or Low). BACKLITE: Time -Out Enabled/Disabled: Time -Out Enabled: The LCD backlight will turn off after two minutes of no control panel key pad activity. After three minutes of no key pad activity the LCD will turn off. When the LCD and/or the Backlight are off, any button press will turn the LCD and backlight back on. After that, the control panel buttons are in normal operating mode. Time -Out Disabled: The LCD and backlight will stay on continuously and will not timeout. HTRADDR: Set the heater address (1 - 16) for automation control. BP -VALVE (By-pass Valve): Enabled/Disabled By-pass Valve Description The purpose of the automatic BPVALVE (bypass valve) feature is to by-pass the flow of water from the heater inlet to the heater outlet when the heater is not firing. There is a minimal amount of water flow through the heater when the heater is not firing, and a maximum water flow through the heater when the heater is firing. For more information about Manual By -Pass and Automatic By -Pass valves, see page 14-15. By -Pass Enabled When the BYPASS VALVE feature is enabled and there is a call for heat, the by-pass valve closes to allow water to flow through the heater. It takes 30 seconds for the bypass valve to rotate to the closed position. This allows the valve to complete rotation so there is sufficient water flow and pressure to prevent the water pressure switch from trigging an error. When the call for heat ends, the water flow continues through the heat exchanger for a cool down period of one minute. After the cool down period, the by-pass valve will rotate so that water no longer flows through the heater. By -Pass Disabled When the BYPASS VALVE feature is disabled, there is no automatic switching of the by-pass valve when the heater starts a heating cycle. The valve stays in the position and water always flows through the heater. LANGUAGE: English, Spanish or French VERSION: View the current heater firmware version. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 48 Section 5. Troubleshooting Troubleshooting Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that the time clock is correctly set and is running. CAUTION: Installing the BLACK 120 VAC plug in the control box and then connecting the heater to a 240 VACt line will destroy the transformer, control broad, and ignition control module, and will void the warranty. If you install the RED 240 VAC plug and then connect the heater to a 120 VAC line, the heater will not operate. See page 34. READ THE FOLLOWING INFORMATION CAREFULLY 1. Check the line voltage to your heater. This heater will operate on either 120 Volts AC or 240 Volts AC. 2. Remove the covers and check the 12-pin plug in the back of the control box. The plug must match the voltage in the heater circuit. 3. If the 12-pin plug is not plugged into the back of the control box, select the correct plug from the bag in the control box and plug it in. The BLACK plug is for 120 volts, the RED plug is for 240 volts. Error and Fault Codes Table 8. Heater Error and Fault Codes Fault Condition Error Code Note Troubleshooting Displayed Water pressure switch ERR PS If water flow is established the No water flow thru open the error is cleared and normal heater operation is resumed. Hi temperature limit ERR HLS When the temperature falls Water temperature after switch open below 135°F the error is cleared the 15t pass through the and normal operation is heater exchanger is more resumed. than 1357. Air flow switch open ERR AFS If adequate air flow through the The blower is not on or blower is established within 60 air thru it is being seconds the heater will resume restricted normal operation. If the error is not corrected within 60 seconds the heater will need to turned off by pressing the HEATER OFF button. Ignition Control Module ERR IGN To clear the error the HEATER The Ignition Control OFF button must be pressed. Module was not able to ignite the heater. Automatic gas shuttoff ERR AGS The front panel buttons will be Water temperature after disabled. To reset the heater, the 2"d pass thru the heat cycle power. exchanger is more than 1407 Excessive stack flue ERR SFS The front panel buttons will be The temperature of the temperature disabled. To reset the heater, stack flue is more than cycle power. 4807 Open stack flue sensor E05 Follow diagram on page 54 Shorted stack flue E06 The front panel buttons will be Follow diagram on page sensor disabled. To reset the heater, 54 cycle power. Open water E01 To clear the error the HEATER Follow diagram on page temperature sensor OFF button must be pressed. 53 Shorted water 126 Follow diagram on page temperature sensor 53 MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 5. Troubleshooting 49 Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that the time clock is correctly set and is running. IMPORTANT! READ ME FIRST! NOTICE: Installing the black120 volt plug in the control box and on either 120 Volts AC or 240 Volts AC. then connecting the heater to a240 volt linewilldestroythetrans- 2. Remove the covers and check the 12-pin plug in the back of the former, control broad, and ignition control module, and will void the control box. The plug must match the voltage in the heater circuit. warranty. If you install the red 240 volt plug and then connect the 3. If the 12 pin plug is not plugged into the back of the control heater to a 120 volt line, the heater will not operate. box, select the correct plug from the bag in the control box READ THE FOLLOWING CAREFULLY: and plug it in. The BLACK plug is for120 volts, the RED plug 1. Check the line voltage to your heater. This heater will operate is for 240 volts. See page 34. Start here for directions to specific Troubleshooting Chart Is POOL OR SPA displayed on NO Go to chart "HEATER WILL the LCD? See page 48. NOT FIRE - A" (Page 50) YES See ALARMS. Heater Error YES Go to chart "HEATER WILL and Fault Codes, page 48. NOT FIRE - B" (Page 51) NO Go to ALARMS in the menu YES Are any ALARMS YES Go to specific safety switch tree of the control board. shown on LCD? o. troubleshooting chart See page 52. (Pages 44 and 45) NO NO Turn off power to heater for about 5 seconds, and turn back on. Make sure tempera- ture setting is above water temperature. Wait one minute. NO Is the "Heating" LED YES Go to chart `HEATER WILL NOT FIRE -A and B Are any errors displayed on blinking? (Page 50 and 51) LCD? NO Verify that water temperature setting is above water temperature reading. If it is, and heater either will not fire or NO ERRORS are displayed. Replace Controll Baord. OWARNING Hazardous voltage. Can shock, burn or kill. AWARNING Fire and Explosion hazard. Do not jumper Disconnect power before servicing any components. switch terminals to remedy a failed safety switch. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 50 Section 5. Troubleshooting Heater Will Not Fire - A Start Is POOL or SPA NO Press Pool/Spa button on YES Heater should fire on demand displayed on the LCD? pad. Does POOL or SPA for heat. displays on LCD? YES NO Check that correct 12-pin YES Check for line voltage to NO plug is installed (red is heater. Restore power to heater. 240V, black is 120V) YE S NO Check for 24 VAC at If plug is not installed: YES secondary of Transformer. Check wiring connections Install correct plug. NO between power supply and 240V plug in 120V Junction Box and between circuit: Replace with Check for Line Voltage NO Junction Box and Terminal correct plug. 120V plug in240V between L1 and L2 terminals Terminal Board. Board; restore continuity. circuit: Replace trans- on former, control board, YES Check wiring connections and ignition control between Terminal Board and module (see "HEATER Check for Line Voltage at NO Transformer primary and WILL NOT FIRE-B Transformer primary pins. restore continuity. page 51. White connects to Pin 3 on Check fuse and all Transformer, Black to Pin 2, other 24V components Orange to Pin 1. YES for damage. 240V: check Pini to Pin 3. Replace Transformer. 120V: check Pin 2 to Pin 3. Jumper Fireman's Switch at YES Check Fireman's Switch circuit Terminal Board and depress connections (time clock, wiring, POOUSPA On button on external controller relay). membrane pad. Does "SPA" or "POOL" display?. NO YES m Leaving jumper in place, NO Remove jumper. Check wiring between Transformer and J7 check for VAC between terminals on Control Board Fireman's Switch terminals and between J7 and and ground. Fireman's Switch on Terminal Board, check fuse, and Remove jumper. Check ribbon restore continuity. cable connection between Membrane Pad and J6 on Control Board. Depress YES Heater should fire on NO POOUSPA On button is on o demand for heat. again. Does "POOL" or "SPA" display? Y� Replace Membrane Pad. Jumper J6-6 and J6-3. Does mode toggle between POOL and SPA? NO Replace Control Board. GO TO "HEATER WILL NOT FIRE - B" Page 51. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 5. Troubleshooting 51 Heater Will Not Fire - B Start Is ERR PS displayed YES on LCD? YES NO Verify that pump is on, filter is not blocked, and the water flow is above the minimum requirement. YES With pump running, adjust Water Pressure Switch to lower pressure until ERR PS goes out. Then verify that ERR PS goes on with pump off. NO NO YES Check that water pressure is NO within the adjustment range of the Pressure Switch (0-5 psig) y YES Verify that switch wiring is OK CONTINUE and Pressure Switch port is not blocked, and replace water Pressure Switch. Check if any of the other Alarms are activated. NO Go to ALARMS Diagnostics (Pages 53 and 54). YES Service pump/filter and elimi- nate other flow obstructions. Heater should fire on call for heat. Re -verify that water flow is above minimum require- ment. Minimum Flow Requirements Model Flow 175 20 gal/min (76 LPM) 200 20 gal/min (76 LPM) 250 25 gal/min (95 LPM) 300 30 gal/min (114 LPM) 400 40 gal/min (151 LPM) If water pressure is outside of adjustment range that will open switch with pump off and close switch with pump on, replace with flow switch set above minimum flow requirement. Minimum Flow Requirements Model Flow 175 20 gal/min (76 LPM) 200 20 gal/min (76 LPM) 250 25 gal/min (95 LPM) 300 30 gal/min (114 LPM) 400 40 gal/min (151 LPM) Go to "Diagnostic. (Pages 53 and 54) Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 52 Section 5. Troubleshooting Gas flow during ignition and I YES Verify connection to HSI igniter, burner fire for less than 7 seconds. HSI is not broken, flame current status. NO NO Gas flow during ignition try, but burner does not fire. YES Check voltage across igniter YES Check gas pressure. Ok? YES Replace HSI igniter leads, ok. NO I NO Replace ignition control module. Increase gas flow into heater: On a 120 V installation check the • Replace gas line. with larger line. ignitor for damage if it has seen • Replace regulator 240 VAC. • Replace meter, or • All of the above. Did blower come on? NOReplace Control board. YES Verify that gas is flowing to burner Verify that gas supply is open all during ignition try. Observe gas NO the way to Gas Valve, and Gas meter for movement during ignition Valve is set at "on" position. YES Replace Gas Valve 30 try (wait for about 30 seconds after Check for 24 VAC to Gas Valve with identical part. calling for heat) terminals during ignition try. (Voltage appears about 24 seconds after call for heat). SEE NOTE 2 YES Verify connection to HSI igniter, NO HSI is not broken, flame current ctati is Check for 24 VAC between NO YES TH and GND terminals on Ignition Control Module. SEE NOTE 1 Check for 24 VAC between VAL and GND terminals on ignition Control Module. SEE NOTE 2 YES J. NO Replace ignition Control Board. Check for 24 VAC between NO Replace Control TH and GND terminals on Board. Control Board. SEE NOTE 1 YES Fix wiring between TH and GND terminals of ignition Control Module and Control Board. Check for 24 VAC between YES Check for 24 VAC between YES VAL and GND terminals on GAS terminals on Control Control board. Boards. SEE NOTE 2. SEE NOTE 2 NO NO Fix wiring between VAL and Replace Control GND terminals of Ignition board. Control Module and Control Board. Fix wiring between GAS terminals on Control Board and Gas Valve. NOTE 1:Voltage appears immediately after call for heat, and may be on for only about 30 seconds. NOTE 2: Voltage appears about 24 seconds after Lcall for heat, and may be on for only about 7 seconds J MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 5. Troubleshooting 53 ' ' • Verify that water flow rate is NO Service pump and filter to above minimum required for restore proper flow. After ser- heater. vicing, verify proper operation Replace High Limit YES of Pressure Switch (PS). Switch (HLS) or Automatic Gas YES Verify that inlet water temper- NO Shutoff (AGS) ature is below 104' F. Replace thermistor or Control CONTINUE Board to correct overheating. If problem persists, verify proper operation of Internal Bypass Valve and Thermal Governor, and check for Heat Exchanger blockage. - Verify that water flow rate is NO Service pump and filter to above minimum required for restore proper flow. heater. Verify that wiring is YES CONTINUE OK and pressure tap if is not blocked. Re- CONTINUE Adjust Water Pressure Switch to close with pump running and open with place Pressure Switch pump off. - Does Blower operate? YES Verify that there is no block- age in Blower intake, Heat NO Exchanger, and exhaust and YES Disconnect Blower and check that exhaust is not too long "Indoor Replace Blower. for line voltage between pins (see Vent Installation", 1 and 3 of Blower Connector Page 22. on ignition try. Verify correct connection of Verify that wires BM NO wiring and that pressure taps and F1 are correctly to AFS are OK. connected at the YES Check for 24 VAC between Verify that vinyl tubing to AFS terminal strip (see 24 VAC and GND terminals and Blower is not misrouted, Heater Connection on Ignition Control Module on kinked, disconnected, or Diagram, Page 36). NO ignition try. Check that IND punctured. wire is correctly connected. Replace Air Flow Switch NO (AFS). Verify correct If problem persists, replace connection of wiring between Blower. YES 24 VAC and IND terminals on Ignition Control Module and Control Board, and replace Control Board. y �" Connect correctly and retry. Disconnect wires F1 NO Does Blower start? and F2 from Ignition Control Module and NO short them together. Replace Blower. Does Blower Does Blower come 0 NO start on ignition try? on? YES Replace Ignition Control Module. Verify Thermistor wiring. If OK, replace Thermistor. ACAUTION Do not jumper a safety switch to NOTE: ES1 is a spare and should be jumpered. •emedy a failed switch. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 54 Section 5. Troubleshooting Heater starts and runs OK, but temperature of exhaust climbs to 4500-5000 in 3-5 minutes. NO Heater starts after several tries, exhaust temperature stays below 250°. OR Heater doesn't start at all (exhaust stays cold). Check pressure and volume of fuel supply OK Disconnect the sensor and check continuity across its terminals. Resistance should be 3.5-4.0 mega - ohms. = open circuit; 0 = shorted. Does sensor check OK? YES Check continuity in wiring harness between Control YES Board and Probe. Continuity OK? NO Check the J3 and J6 connectors for corrosion/ looseness on the male pins. YES Clean/tighten pins sas nIeeded. DONE F. FReset power to Heater retry. Heater should fire. Check Heat Exchanger INO Coil for leaks, liming, soot, or low flow. YES YES Check Thermal Regulator: Open at 120°? NO YES Correct problem; Heater should fire. NO YES Check Thermal -Regulator: seats correctly? NO NO Correct Fuel Supply, reset Heater and retry. Heater should fire correctly. NO Replace Stack Flue Sensor DONE [Reset power to Heater and try. Heater should fire. NO MCI Repeat checks on fuel supply, Thermal Regulator, check for correct orifices, etc. YES NO Replace Heater (HD) Membrane Pad. DONE Does the LCD show Error Code "E05" or "E06,, ? NO (Basic) Replace Heater Control Board. DONE Reset power to Heater and retry. Heater should fire. NO Check Heat Exchanger Coil for leaks, liming, soot, or low flow. Replace Heater Control Board. DONE Reset power to Heater and retry. Heater should fire. NO Replace Heater Membrane Pad. DONE Reset power to Heater and retry. Heater should fire. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 5. Troubleshooting 55 Burner Troubleshooting SYMPTOM CAUSE REMEDY Loud, high-pitched whine Flame is too rich. Verify pressure tap between gas valve and blower inlet. Seepage 15 and verify that the gas regulator setting is —0.2" (-0.5cm) wc. Contact a qualified technician or service agency to replace the gas orifice. Flame is "fluttery." Flame is too lean. Seepage 16 and verify that the gas Exhaust may have acrid regulator setting is —0.2" (-0.5cm) wc. smell or burner may fail Contact a qualified technician or service to stay lit. agency to replace the gas orifice. Burner pulsates or Exhaust vent is too long. Reduce length of exhaust vent and/or surges, especially on number of elbows. ignition. Combustion appears Flame current is not Checkfor wet or damaged igniter with normal, but flame does being sensed. low resistanceto ground. Replacewith not stay lit. new igniter. Verify burner flameholder is properly grounded. Replace Ignition Control Module. Heat Exchanger Troubleshooting SYMPTOM CAUSE REMEDY Boiling in heat exchanger. Low water flow to heater. Service pump and or filter. May be accompanied by Heat exchanger plugged. Service heat exchanger. Correct water "bumping" sounds. chemistry. Bypassvalve stuck open. Service bypass valve. Thermal governor stuck Replacethermal governor. closed. Sweating. Thermal governor failed. Replacethermal governor. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 56 Section 6. Maintenance CARE AND MAINTENANCE ©WARNING Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. The following maintenance is recommended every six months and at the start of every swimming season: 1. Inspect the heater panels and venting system to make sure that there are no obstructions to the flow of ventilating air or burner exhaust. Check that room air intakes are open and clear of obstructions. 2. Keep the area in and around the heater clear and free from combustible materials, gasoline and other flammable vapors and corrosive liquids. 3. Test the operation of the pressure relief valve by lifting the valve lever (if installed). 4. Test for proper operation of the water pressure switch. (See "WATER PRESSURE SWITCH" (page 44) for testing instructions). 5. On enclosed installations with high -temperature Special Gas Vent systems, repeat the "Final Installation Check," page 33. Check for evidence of joint leakage. Make sure that joints have not slipped partially or completely apart. Check pipe and fittings for cracks or breaks. The combustion air blower is permanently lubricated, and does not require periodic lubrication. The burner does not require maintenance or adjustment by the user. Call a qualified service technician if you suspect that the burner may require maintenance. PRESSURE RELIEF VALVE (NOT FACTORY INSTALLED) Canadian code requires and some U.S. local codes may require installation of a Pressure Relief Valve (PRV). Purchase separately and install (P/N 460925) a 3/4" pressure relief valve complying with the ANSI/ASME Boiler and Pressure Vessel Code, having a capacity equal to the Btu/hr rating of the heater. The relief pressure of the valve MUST NOT EXCEED 50 PSI. The relief valve must be installed vertically. To 314" x 3.5" Brass install the valve, use a 3/4" x 3-1/2" brass nipple at the manifold and two Nipple (2) brass elbows and nipples (supplied), as shown in Figure 34. No valve (2.0 cm x 8`cm) is allowed to be placed between the manifold adapter and the relief valve. Note: Be sure to use threaded seal tape (PTFE) or equivalent, on all treaded metal pipe connections. To avoid water damage or scalding from operation of the relief valve, install a drain pipe in the outlet of the pressure relief valve that will direct water discharging from the valve to a safe place for disposal. DO NOT install any reducing couplings or valves in the drain pipe. The drain pipe must be installed as shown in Figure 43 to allow complete drainage from the valve and drain line. Important! The relief valve should be tested at least once a year by lifting the valve lever. � `PRV 3 4" x 2.0" Brass Nipple (2.0 cm x 5.08 cm) Drill through the NPT Port, then use a 3/4" x 2.50 (2.0 cm x 6.35 cm) Brass Nipple and Elbow (user supplied) for a PRV Installation Figure 43. NOTE: FOR NEW HEATER INSTALLATION: For rodent heater protection, please refer to next page for gas pipe escutcheon installation. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 6. Maintenance 57 Optional Pressure Relief Valve Escutchen: Note: If the heater is equipped with an optional Pressure Relief Valve, use the escutcheon on the Pressure Relief Valve water pipe. If required, before installing the escutcheon, carefully remove the round Pressure Relief Valve knock out from the heater panel. The pressure relief water pipe escutcheon ensures the heater is rodent resistant. The following describes how to install the water pipe escutcheon for a new heater installation. The water pipe escutcheon should be installed when the water pipe is being installed to the heater. See page 61 for parts list. To install the water pipe escutcheon: 1. Place the water pipe escutcheon over the water pipe, see Figure 44. 2. Slide the escutcheon flush against the heater panel. 4. Hand -tighten the retention screw to secure the escutcheon in place. Tool: Phillips Screwdriver Escutcheon retaining screw Escutcheon installed over water pipe Figure 44. Water Pipe with Escutcheon Installed. (with optional Pressure relief valve shown) Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 58 Section 6. Maintenance AFTER START-UP CHECKING WATER FLOW WARNING FIRE OR FLOODING HAZARD. IF THE UNIT OVERHEATS AND THE BURNER FAILS TO SHUT OFF, FOLLOW INSTRUCTIONS UNDER "TO TURN OFF GAS TO THE APPLIANCE" (PAGE 43), AND CALL A QUALIFIED SERVICE TECHNICIAN TO REPAIR UNIT. After start-up, the outlet water pipe should feel slightly warmer than the inlet pipe. If it feels hot, or if you hear the water in the heater boiling, there may not be enough water flow to the appliance. Make sure that the filter is not plugged. If water temperature remains high but the unit continues to operate, turn off the appliance and call your service technician. SPRING AND FALL OPERATION If the pool is only used occasionally, lower the pool thermostat to 68' F (20' C) and leave the heater on. This will keep the pool and the surrounding ground warm enough so that the heater should restore the pool to a comfortable temperature within about one day. WINTER OPERATION Operating this heater continuously at water temperatures below 68' F. (20° C) will cause harmful condensation and will damage the heater and void the warranty. If the heater has been drained for freezing condition, do NOT turn "ON" until the system is circulating water. Water trapped in the heat exchanger can result in freeze damage to the exchanger or headers. Freeze damage is specifically not covered by the warranty. When starting the heater for the swimming season with a water temperature below 50' F (100 C), the heater may be used to heat the water; however, make sure that the heater operates continuously until the water temperature reaches the heater's minimum setting of 680 F (200 C). During cold weather, if there is no danger of freezing, operate the filter pump continuously even if the heater is not operating. If air temperatures are expected to drop below freezing (320 FI0° C), shut down the heater and winterize it. For outdoor heaters in freezing climates, shut the heater down and drain it for winter as follows: 1. Turn off electrical supply to the heater and pump. 2. Close main gas control valve and manual gas valve (located outside the heater). Turn switch on heater gas valve to OFF. In northern climates where they may be required, open drain cock located on the bottom of the manifold adapter, and drain the heat exchanger and manifold adapter completely. If heater is below pool water level, be sure to close isolation valves to prevent draining the pool (isolation valves are not required and should not be used on heaters installed above pool water level except when needed for winterizing valves). Assist the draining by blowing out the heat exchanger through the pressure switch fitting with low pressure compressed air (less than 5 PSI or 35 kPa). ©WARNING Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI or 35 kPa), high volume blower when air purging the heater, pump, filter, or piping. 4. Remove the Water Pressure Switch. Plug the port in the manifold to prevent bugs and dirt from getting into the manifold. 5. Drain the plastic inlet/outlet manifold through the outlet pipe. If the pipe does not drain naturally to the pool, install a drain cock in the outlet pipe to drain the manifold. 6. Cover air inlet grate with a plastic bag to prevent bugs, leaves, etc., from getting into the heater. NOTICE: Water trapped in the heater can cause freeze damage. Allowing the heater to freeze voids the warranty. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 6. Maintenance 59 To return the heater to service after winterizing: Close drain cock and fittings. Before starting the heater, circulate water through the heater for several minutes until all air noises stop. See also `BEFORE START-UP" (page 42) and "CARE AND MAINTENANCE" (page 56). (See additional notes under Important Notices in Introduction.) MAINTAINING POOL TEMPERATURE To maintain pool temperature, make sure that the heater switch and valving are reset to pool settings after using the spa. ENERGY SAVING TIPS Keep the pool or spa covered when not in use. This will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on the filtering system. 2. Reduce pool thermostat to 78' F (25' C) or lower; reduce spa temperature to 100' F (38' Q. This is accepted as being the most healthy temperature for swimming by the American Red Cross. 3. Use a time clock to start the filter pump at 6 a.m. or later. The swimming pool loses less heat after daybreak. 4. For pools used only on weekends, lower the thermostat setting by 10' F to 15' F (5° C to 8° C) during the week to reduce heat loss. A properly sized heater will restore normal temperature within one day. 5. Turn the heater off when the pool will not be used for an extended period. 6. Follow a regular program of preventive maintenance for the heater each new swimming season. Check operation of the heater and its controls. CHEMICAL BALANCE POOL AND SPA WATER Your pool heater was designed specifically for your spa or pool and will give you many years of trouble -free service, provided you keep your water chemistry in proper condition. Water chemistry should follow good swimming pool water chemistry practices. When using a chlorinator, install it down stream from the heater and at a lower level than the heater outlet. Install a corrosion resistant positive seal "Check Valve", (P/N R172288), between the heater and the chlorinator to prevent concentrated chemicals from back -siphoning into the heater. Back -siphoning is most likely to occur when the pump stops, creating a pressure -suction differential. Do NOT sanitize the pool by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high concentration of chlorine to enter the heater, which could cause corrosion damage to the heat exchanger. Three major items that can cause problems with your pool heater are: improper pH, disinfectant residual, and total alkalinity. These items, if not kept properly balanced, can shorten the life of the heater and cause permanent damage. ©CAUTION Heat exchanger damage resulting from chemical imbalance is not covered by the warranty. WHAT A DISINFECTANT DOES Two pool guests you do not want are algae and bacteria. To get rid of them and make pool water sanitary for swimming - as well as to improve the water's taste, odor and clarity - some sort of disinfectant must be used. Chlorine and bromine are universally approved by health authorities and are accepted disinfecting agents for bacteria control. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 60 Section 6. Maintenance CHEMICAL BALANCE, (continued) It is wise to test pool water regularly. Never allow chlorine residual to drop below 0.6 ppm (parts per million). The minimum level for effective chlorine or bromine residual is 1.4 ppm. pH - The term pH refers to the acid/alkaline balance of water expressed on a numerical scale from 0 to 14. A test kit for measuring pH balance of your pool water is available from your local pool supply store; see Table 9. Muriatic Acid has a pH of about 0. Pure water is 7 (neutral). Weak Lye solution have a pH of 13-14. NOTE: 7.4 to 7.6 is a desirable pH range. It is essential to maintain correct pH, see Table 9. If pH becomes too high (over alkaline), it has these effects: 1. Greatly lowers the ability of chlorine to destroy bacteria and algae. 2. Water becomes cloudy. 3. There is more danger of scale formation on the plaster or in the heat exchanger tubing. 4. Filter elements may become blocked. If pH is too low (over acid) the following conditions may occur: 1. Excessive eye burn or skin irritation. 2. Etching of the plaster. 3. Corrosion of metal fixtures in the filtration and recirculation system, which may create brown, blue, green, or sometimes almost black stains on the plaster. 4. Corrosion of copper tubes in the heater, which may cause leaks. 5. If you have a sand and gravel filter, the alum used as a filter aid may dissolve and pass through the filter. CAUTION. Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is 6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry. NOTE: Chemicals that are acid lower pH. Chemicals that are alkaline raise pH. ALKALINITY High or Low: "Total alkalinity" is a measurement of the total amount of alkaline chemicals in the water, and control pH to a great degree. (It is not the same as pH which refers merely to the relative alkalinity/acidity balance.) Your pool water's total alkalinity should be 100 - 140 ppm to permit easier pH control. A total alkalinity test is simple to perform with a reliable test kit. You will need to test about once a week and make proper adjustments until alkalinity is in the proper range. Then, test only once every month or so to be sure it is being maintained. See your local pool dealer for help in properly balancing the water chemistry. WATER CHEMISTRY PARAMETERS Table 9 Disinfectant levels Minimum Ideal Maximum Free Chlorine, ppm 1.0 2.0-4.0 5.0** Combined Chlorine, ppm None None 0.2 Bromine, ppm 2.0 4-6 10.0 Other Sanitizers Levels not established. Consult local health department before use. Chemical Values pH 7.2 7.4-7.6 7.8** Total Alkalinity (Buffering), ppm 60 80-100 180 as CaCO3 Salt ppm 2000 3200 5000** Total Dissolved Solids, ppm N/A N/A 1,500 ppm > TDS at startup* Calcium Hardness, ppm, as CaCO3 150 200-400 500-1,000 Heavy Metals None None None Biological Values Algae None None None Bacteria None None Refer to Local Code *Start-up TDS includes source water TDS and any other inorganic salt added at start-up. NOTE (**): Failure to adhere to the listed water chemistry parameters may result in premature failure of the heat exchanger and will void the heater warranty. MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 7. Replacement Parts 61 MASTERTEMP HEATER REPLACEMENT PARTS Lista de piezas resistentes a roedores (consulte tambien la pagina 62) 29. N / P 476155Z - Tornillo, autoperforante, cabeza hexagonal (usar con N/P 467150Z) 30. P / N 47615OZ - Escape con escudo, calentador MasterTemp resistente a roedores 31. P / N 462037Z - Inserto del colector de agua, solo calentador MasterTemp 32. P / N 462038Z * - Inserto del colector de agua, solo calentador ASME MasterTemp 33. P / N 467107Z - Escudo de tuberia de gas 34. P / N 270114Z - Tornillo Phillips (# 8), para escudo (usar con P/N 467107Z) (*) Para calefactores ASME, se usa el N/P 462038Z en Iugar del N/P 462037Z. ---------------------------------------- -- '1� I Escutcheon Para una lista de Piezas del Sister (Numeros del 1 ver pagina 65. wo Para una lista c Piezas del Sisti (Numeros del 8 ver pagina 64. L-- .ra una lista detallada de las )zas del Sistema del Quemador umeros del 5 al 7), r pagina 62 31/32 Repair Parts are available from a Pentair dealer. If your dealer cannot supply you, call Customer Support at 1-800-831-7133. Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 62 Section 7. Replacement Parts For Heater mountin bolts and clamp purchase sep Bolt Down Bracket Part No. 460738. F CLAMP LID TUB DESIGN ' Combustion I Chamber Clamp Assy— I I I I I — � I I I I i a I n�a 20 I I I I Combustion I Chamber O-ring 15 I =_ I Y qo I ' For heaters manufactured between 1 /12/2009 and 10/31 /2013 ' (clamp lid tub design) Note: Kits also include Clamp Assembly, O-Ring and Silicon Tube ' (see page 63) Rodent Resistant Parts List I � (see page 63) 29. P/N 476155Z Escutcheon�7.—_i 30. P/N 47615OZ ) 31. P/N 462037Z ' I 132. P/N 462038Z* 33. P/N 467107Z 34. P/N 270114Z M For ASME heaters P/N 462038Z is used instead of P/N 27589Z. 22 0Q Ignitor Flameholder—_ Insert 8 '-1 9 10 11 �12 21 1 3 2 4 i ®\ \ 7 a 6 \5 Lid Nut/Washer (9x) l�,C a '�• ® 20 T5 19 29 30 026 27 28 ° moo® 23 18 (D-Combustion Chamber Gasket as 13 ®aa 17 \a°° 16 °® 23 24 I ,OI 31/32 MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 7. Replacement Parts 63 MASTERTEMP HEATER REPLACEMENT PARTS REPAIR PARTS — BURNER SYSTEM Key Part Model 20ONA 30ONA 40ONA No. Description City. 20OLP 30OLP 40OLP 1 Combination Gas Control Valve Kit 1 42001-0051S 42001-0051S 42001-0051S 2 3/4" Union 2 38404-4097S 38404-4097S 38404-4097S 3 Gas Orifice 1 4 Gas Orifice O-Ring 1 • Gas Orifice Kit — NG (Incl. Key Nos. 3 and 4)t 77707-0431 460753 77707-0411 • Gas Orifice Kit — Propane (Incl. Key Nos. 3 and 4)t 77707-0461 460754 77707-0441 • NG to Propane Conversion Kit (Incl. Key Nos. 3 and 4)t 77707-1461 460755 77707-1441 • Propane to NG Conversion Kit (Ind. Key Nos. 3 and 4)t 77707-1431 460756 77707-1411 5 Air Blower Kit Natural Gas Units 1 77707-0251 460757 77707-0253 Propane Units 1 77707-0254 460758 77707-0256 • Air Orifice Kit (Includes Key Nos. 6 and 7) 1 77707-0111 460759 77707-0113 6 Air Orifice 1 7 Air Orifice Grill 1 42001-0114S 42001-0114S 42001-0114S • Blower/Adapter Plate Gasket Kit (Includes Key Nos. 8, 9, 10, 12) 1 77707-0011 77707-0011 77707-0011 • Flameholder Kit (Includes Key Nos. 10, 11, 12, 13 and on 300 & 400 models only - Flameholder Insert) 1 77707-0202 77707-0203 77707-0204 8 Blower/Adapter Plate Gasket 1 9 Blower Adapter Plate 1 10 Flameholder/Adapter Plate Gasket 1 11 Flameholder Assembly 1 12 Flameholder/Combustion Chamber Gasket* 1 13 Flameholder Insulation Cap 1 • Flameholder Insert 1 14 Condensate Evaporator Plate 1 15 One Piece Metal Chamber/Combustion Chamber Assembly 1 474095 474095 474095 474957 474957 474957 42001-0200S 42001-0200S • Insulation Kit (Includes Key No. 13,14,16,17,18,19) 1 77707-0008 77707-0008 77707-0008 16 Bottom Outer Insulation Blanket* 1 17 1" Bottom Inner Insulation 1 18 1" Top Insulation 1 19 Top Outer Insulation Blanket* 1 • Lower Enclosure Insulation 1 42001-0074S 42001-0074S 42001-0074S 20 One Piece Metal Elbow/Combustion Chamber Cover Assembly 1 474094 474094 474094 474958 474958 474958 42001-0214S 42001-0214S 42001-0214S • Combustion Chamber O-Ring Kit 1 474201 474201 474201 474952 474952 474952 21 Metal Vent Cover 1 42002-0005S 42002-0005S 42002-0005S Cover Assembly 1 42001-0214S 42001-0214S 42001-0214S 22 Heater Top 1 42002-0034Z 42002-0034Z 42002-0034Z 23 Side Panel (Service Panel) 1 42002-0039 42002-0039 42002-0039 24 Side Panel (Manifold} 1 42002-0033 42002-0033 42002-0033 25 Heater Bottom 1 42002-0031 42002-0031 42002-0031 26 Side Panel {Flue Stack} 1 42002-0032 42002-0032 42002-0032 27 J-Box Cover 1 42002-0041 42002-0041 42002-0041 28 Screw Kit, Panel 1 474292 474292 474292 Combustion Air Intake Duct Connection Kit 1 461031 461031 461031 " Not available separately. t Not included with heater. Order separately. For heaters manufactured between 1/12/2009 and 10/31/2013 (clamp lid tub design) Note: Kits also include Clamp Assembly, O-Ring and Silicon Tube. For heater manufactured AFTER 10/31/2013 (New 9-bolt lid tub design) For heater manufactured BEFORE 1/12/2009 Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide 64 Section 7. Replacement Parts MASTERTEMP HEATER REPLACEMENT PARTS 1 n I I 22 21 0 20 REPAIR PARTS — WATER SYSTEM Key Part Model 175NA - 20ONA 30ONA 40ONA No. Description oty. 175LP-20OLP 30OLP 40OLP 1 Tube Sheet Coil Assembly Kit (NA, LP Series) (Includes Key No.3) 1 77707-0232 77707-0233 77707-0234 474058 474060 474061 1 Tube Sheet Coil Assembly Kit (NA - HD Series) (Includes Key No.3) 1 — — 77707-0244 — — 474065 1 Tube Sheet Coil / Combustion Chamber Kit (ASMESERIES) Bronze Header - Key Nos. 3-12, 15, 20-22, 1 — — 460940 472732Z — 474096 — 474956 1 Tube Sheet Coil / Combustion Chamber Kit (HD ASIV E SERIES) — — 474350, 474953 2 Manifold Kit (Includes Key Nos. 3-14, 21, & Key Nos. 5-7 in "Electrical System", Page 53 1 77707-0014 77707-0015 77707-0016 • Basic Manifold Kit (includes Key No. 3,5,10-14) 474200 474200 474200 3 Coil/TubesheetSealing O-Ring Kit () 77707-0117(6) 77707-0118(10) 77707-0119(12) 4 Manifold Bottom Plate 1 5 Manifold O-Ring 1 O-Ring Kit (Incl. Key Nos. 3, 5) 1 77707-0120 77707-0120 77707-0120 6 Manifold Insert* 1 7 Manifold Baffle Plate 1 8 Manifold Bypass Valve 1 77707-0001 77707-0001 77707-0001 9 Water Pressure Switch 1 42001-0060S 42001-0060S 42001-0060S 10 Manifold 1 11 5/16" Washer, S.S. 10 12 5/16x18x2-3/4" Hex Cap screw 10 13 Connector Tube O-Ring 2 1-19-226 U9-226 1.19-226 14 Connector Tube Kit (Includes 1 Connector Tube and 1 O-Ring) 2 77707-0017 77707-0017 77707-0017 15 Thermal Regulator Kit (Incl. Key No. 16, 17, 18, 19 and Spring Clip) 1 77707-0010 77707-0010 77707-0010 16 Thermal Regulator (Includes Spring Clip) 1 38000-0007S 38000-0007S 38000-0007S 17 Thermal Regulator Spring 1 18 Thermal Regulator Cap O-Ring 1 35505-1313 35505-1313 35505-1313 • Thermal Regulator Spring Clip 1 19 Thermal Regulator Cap 1 20 Drain Plug 1 U178-920P U178-920P U178-920P 21 3/4" Pipe Plug 1 U78-60ZPS U78-60ZPS U78-60ZPS 22 Pressure Relief Valve (Recommended - (Purchase Separately) 1 38674-0719 38674-0719 38674-0719 Not available separately. • Not illustrated. For heaters manufactured between 1/12/2009 and 10/31/2013 (clamp lid tub design) - Note: Kits also include Clamp Assembly, O-Ring and Silicon Tube. For ASME heater manufactured AFTER 10/31/2013 (New 9-bolt lid tub design) For heater manufactured BEFORE 1/12/2009 MASTERTEMP Pool and Spa Heater Installation and User's Guide Rev. P 8/2020 Section 7. Replacement Parts 65 MASTERTEMP HEATER REPLACEMENT PARTS 13 0 0 2— 3 4 5 I 7 REPAIR PARTS - ELECTRICAL SYSTEM Model Key Part 200/300/400 NA No. Description Qty. 200/3001400 LP 1 Heater Display Cover 1 42002-0035 2 Igniter Bracket 1 42001-0030S 3 Igniter/Igniter Gasket Kit Incl. Key Nos. 3 and 4) 1 77707-0054 4 Igniter Gasket 1 42001-0066S 5 Automatic Gas Shutoff Switch (AGS) 1 42002-0025S 6 High Limit Switch 1 42001-0063S 7 Thermistor 1 42001-0053S 8 Terminal Board 1 42001-0056S 9 Fireman's Switch Fuse (1.25A, 1-1/4") 1 32850-0099 10 Ignition Control Module 1 476223 11 Transformer, 120/240V 1 42001-0107S 12 Air Flow Switch 1 42001-0061S 13 RS485 Control board & Membrane Pad Combo kit 1 461105 • Heater Wiring Harness - 120/240V 1 461107 • 120/240 Volt Plug Kit 1 42001-0105S 14 RS485 Membrane Pad (NA & LP) 1 461106 Legacy RS-485 Conversion Combo kit* 1 476211 • Membrane Pad (NA, LP Series) (Legacy) 1 472610Z 15 Heater Top 1 42002-0034Z 17 Stack Flue Sensor 1 42002-0024S * Kit Includes: RS-485 control board, RS-485 membrane pad, Ignition Control Module and flame current wire. Not Shown Rev. P 8/2020 MASTERTEMP Pool and Spa Heater Installation and User's Guide ►k� PENTAIR 1620 HAWKINS AVE., SANFORD, INC 27330 •(919)566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 www.pentair.com All indicated Pentair trademarks and logos are property of Pentair Inc. or its global affiliates in the U.S.A. and/or other countries. Third party registered and unregistered trademarks and logos are the property of their respective owners © 2020 Pentair Inc. All rights reserved. This document is subject to change without notice. P/N 472592 Rev. P 8/2020