APPROVED BLD2024-0053+Plumbing_Plan+1.12.2024_2.57.46_PM+3998049ABBREVIATIONS GENERAL AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AFC ABOVE FINISHED GRADE BHP BRAKE HORSEPOWER BOP BOTTOM OF PIPE BOT BOTTOM C/L CENTER LINE CLG CEILING CFM CUBIC FEET PER MINUTE CO CARBON MONOXIDE CO2 CARBON DIOXIDE CSR CURRENT SENSING RELAY DISCH DISCHARGE DN DOWN DS DISCONNECT SWITCH; DOOR SWITCH (E) EXISTING EA EACH EC ELECTRICAL CONTRACTOR; END CAP EP ELECTRICAL PANEL; END PLUG EPO EMERGENCY POWER OFF ESP EXTERNAL STATIC PRESSURE (F) FUTURE FA FIRE ALARM FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FLEX FLEXIBLE FLR FLOOR FP FIRE PROTECTION FTG FOOTING GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR HP HORSEPOWER; HIGH PRESSURE HTG HEATING HTR HEATER IAW IN ACCORDANCE WITH ID INSIDE DIAMETER/DIMENSION IN WC INCHES WATER COLUMN MC MECHANICAL CONTRACTOR MFR MANUFACTURER MH MANHOLE MTD MOUNTED N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN; NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OVHD OVERHEAD PERF PERFORATED POC POINT OF CONNECTION QTY QUANTITY (R) RELOCATED RCP REFLECTED CEILING PLAN REQD REQUIRED SECT SECTION SIM SIMILAR SPEC SPECIFICATION STD STANDARD TBD TO BE DETERMINED TI TENANTIMPROVEMENTS TOC TOP OF CONCRETE TOS TOP OF STEEL TSP TOTAL STATIC PRESSURE TYP TYPICAL UG UNDERGROUND LINO UNLESS NOTED OTHERWISE VFD VARIABLE FREQUENCY DRIVE VSD VARIABLE SPEED DRIVE W/ WITH W/o WITHOUT WC WATER COLUMN WIG WATER GAUGE HVAC AC AHU BDD BOD CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FSD FTU GRID HC HVAC LAT LID MA MOD MAU MUA CA OBD RA RAT RTU SA SAT SD SF SL SLSM SM SO SP TG TOD VAV VD CA CHWR CHWS CLPS CNDS CNDWR CNDWS DRAIN DTR DTS EWT FCD FEED FOF FOR FOS FOV G 2# G 5# G GE GFWR GFWS GWR GWS HPC HPS HWR HWS LPC LPG LPS LWT MPC MPS PCW PCWR PCWS PHW PHWR RL IRS RV SCW SRV TOP AIR CONDITIONING AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DUCT BOARD DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUSTFAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED COMBINATION FIRE/SMOKE DAMPER FAN TERMINAL UNIT GRILLE, REGISTER, DIFFUSER HEATING COIL HEATING, VENTILATION AND AIR CONDITIONING LEAVING AIR TEMPERATURE LINEAR DIFFUSER MIXED AIR MOTOR OPERATED DAMPER; MODULATING MAKE-UP AIR UNIT MAKE-UP AIR OUTSIDE AIR OPPOSED BLADE DAMPER RETURN AIR RETURN AIR TEMPERATURE ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER; SMOKE DETECTOR SUPPLY FAN SOUND LINED SOUND LINED SHEET METAL SHEET METAL SCREENED OPENING STATIC PRESSURE TRANSFER GRILLE TOP OF DUCT VARIABLE AIR VOLUME VOLUME DAMPER STEAM BLOWDOWN BACKFLOW PREVENTER COMPRESSED AIR CHILLED WATER RETURN CHILLED WATER SUPPLY CLEAN LOW PRESSURE STEAM CONDENSATE CONDENSER WATER RETURN CONDENSER WATER SUPPLY TANK OVERFLOW & DRAINS DUAL TEMPERATURE RETURN DUAL TEMPERATURE SUPPLY ENTERING WATER TEMPERATURE FLUE CONDENSATE DRAIN BOILER FEED WATER FUEL OIL FILL FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL VENT NATURAL GAS NATURAL GAS - LOW PRESSURE, 2 PSI NATURAL GAS - LOW PRESSURE, 5 PSI GENERATOR EXHAUST GEO - FIELD WATER RETURN GEO - FIELD WATER SUPPLY GROUND WATER RETURN GROUND WATER SUPPLY HIGH PRESSURE CONDENSATE HIGH PRESSURE STEAM HEATING WATER RETURN HEATING WATER SUPPLY LOW PRESSURE CONDENSATE LIQUEFIED PROPANE GAS LOW PRESSURE STEAM LEAVING WATER TEMPERATURE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM PROCESS COLD WATER PROCESS COOLING WATER RETURN PROCESS COOLING WATER SUPPLY PROCESS HOT WATER PROCESS HOT WATER RETURN REFRIGERATION LIQUID REFRIGERATION SUCTION REFRIGERATION VENT SOFTENED COLD WATER STEAM RELIEF VENT TOP OF PIPE PIPING IDENTIFICATION HVAC RETURN PIPING SUPPLY PIPING PIPING FITTINGS VALVES PIPING ACCESSORIES AV HAV f�CrDr TEE UP TEE DOWN TEE DN W/ ELBOW TEE UP W/ ELBOW 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW REDUCER SLOPE SYMBOL BREAK OR CONTINUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT MOTORIZED 2-WAY VALVE MOTORIZED 3-WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3-WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VALVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3-WAY GATE VALVE PLUG VALVE BALANCING VALVE HOSE BIBB AUTO FLOW VALVE PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR FLOW METER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP FETES PLUG SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR GENERAL INFORMATION SYMBOLS CP (L O O X X X X X X ' X X X c:: X NEW MECHANICAL WORK FUTURE TI SCOPE & NEW WORK OTHER THAN MECH POINT OF CONNECTION POINT OF DEMOLITION CENTERLINE KEY NOTE REFERENCE PIPING RISER CALLOUT (CHW; HW) PIPING RISER # PLAN NUMBER SHEET NUMBER WHERE PLAN SHOWN DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN REVISION NUMBER - DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD - DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION GENERAL NOTES 1. ENTIRE INSTALLATION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE UNIFORM PLUMBING CODE 2018, WASHINGTON STATE BUILDING CODE 2018, INTERNATIONAL BUILDING CODE 2018, WASHINGTON STATE ENERGY CODE (WSEC) 2018, AND ALL OTHER APPLICABLE CODES AND REGULATIONS. 2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS SPECIFICALLY MARKED AS EXISTING, EXIST, OR (E). EXISTING WORK ON DRAWINGS SHALL BE NOTED IN HALFTONE. 3. REFER TO CIVIL DRAWINGS FOR UTILITY WORK 5-0" BEYOND THE BUILDING LINE. COORDINATE EXTERIOR PIPE INVERT ELEVATIONS WITH CIVIL ENGINEER. 4. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. 5. COORDINATE LOCATIONS OF ALL ROOF OPENINGS WITH STRUCTURAL, MECHANICAL, AND ARCHITECTURAL PLANS PRIOR TO ANY INSTALLATION. VENT THROUGH ROOF LOCATIONS SHALL MAINTAIN MINIMUM 15'-0" CLEARANCE WITH HVAC AIR INTAKES. 6. COORDINATE PLUMBING SYSTEMS AND EQUIPMENT SPACES WITH WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 7. PRIOR TO START OF INSTALLATION OF BELOW SLAB PIPING, COORDINATE LOCATIONS OF PIPING AND STRUCTURAL FOOTINGS, GRADE BEAMS, ETC. WITH STRUCTURAL ENGINEER. 8. COORDINATE ALL FLOOR AND WALL PENETRATIONS WITH STRUCTURAL ENGINEER PRIOR TO STARTING WORK. SUBMIT COMPLETE SLEEVE AND CORE DRILL PLANS TO STRUCTURAL ENGINEER FOR REVIEW. 9. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OF OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND SPACE CONDITIONS AT ALL TIMES. 10. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE CODES. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 11. DO NOT ROUTE ANY PLUMBING PIPING INTO ELEVATOR MACHINE, ELECTRICAL OR TELECOMMUNICATIONS ROOMS EXCEPT FIRE PROTECTION PIPING SERVING THAT ROOM. WHERE UNAVOIDABLE DUE TO ARCHITECTURAL OR STRUCTURAL CONDITIONS, PROVIDE SEPARATION/PROTECTION AS APPROVED BY THE AHJ. 12. PROVIDE WATER HAMMER ARRESTOR (WITH ACCESS PANELS WHERE REQUIRED) TO FLUSH VALVES, SOLENOID VALVE OPERATED PLUMBING FIXTURES & ALL QUICK CLOSING VALVES. INSTALL WATER HAMMER ARRESTORS IN ACCORDANCE WITH PDI-WH2O1, LATEST EDITION. 13. PIPING SHALL BE SUPPORTED AND BRACED PER SMACNA GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS. 14. INSTALL FLEXIBLE CONNECTIONS ON ALL SYSTEMS WHERE REQUIRED AT EXPANSION AND SEISMIC JOINTS. REFER TO SPECIFICATION MATRIX. 15. PIPING TO BE INSTALLED AT 2% GRADIENT WHERE POSSIBLE. REFER TO PLANS FOR PIPING INSTALLED AT DIFFERENT SLOPES. 16. ALL SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN PROJECT DRAWINGS, SPECIFICATIONS, WSEC C403.2.8.1, SECTIONS C403.2.8, C403.2.9 AND TABLE C403.10.3 OF WASHINGTON STATE ENERGY CODE, WHICHEVER IS MOST STRINGENT. Irw:����l��yr��y��•�r��z•�u.�:�a►�►u►�e�ya:��►�iu►n►�m►►� 18. INSTALL CLEANOUTS WHERE REQUIRED BY 2018 UPC. ALL CLEANOUTS MUST BE PLACED IN ACCESSIBLE LOCATION. 19. PUBLIC USE LAVATORIES AND HAND SINKS SHALL HAVE A SCALD PROTECTION DEVICE THAT MEETS THE ASSE 1070 STANDARD. 20. HEAT TRACE IS REQUIRED WHERE AMBIENT TEMPERATURES FALL BELOW 50 DEGREES ON A REGULAR BASIS. COORDINATE WITH ELECTRICAL CONTRACTOR TO VERIFY CONNECTION POINT. PLUMBING INDEX SHEET NO. SHEET NAME P-001 PLUMBING LEGEND, MAP, B.O.D. & ABBREVIATIONS P-002 SPECIFICATIONS & SCHEDULES P-111 I PLUMBING DEMO & NEW WORK PLANS VICINITY MAP it, s:sv� 215u,s -.iaercrest Health SW & Rehab Center f Swedish Medical Cogir of Edmonds Q ' Center Edmonds... Assisted Living and... Gift shop 8 Q 1. Stevens Court Apartments Q ,%n 216th St SW Swedish Affairs Edmonds Campus Swedish Urgent Care e Clinic © - Edmonds e o • PugetSound& Cancer Center Steven's Health Center Edmonds Oral & Facial Surgery drew Perryq Puget Sound Hearing Aid �& Audiology- Edmonds / .t Hearing aid store 218th St Sw Q Ellie Javadi, DDS, MSD, stin Pagan, DDS, MSD Orchid Periodontics... g Dick's Drive -In Premier Therapy Hamharger • s Associates ine J. Bunnell, PAQ ®Q WInCo Foods® �CESC< Medical Pathology® Custom Dental Care EVgo Charging Station ociates Med Lab Q Eye Clinic of Edmonds Cornerstone / ®Red Drag, Insurance G p f% Starbucks— 8 Casino fon, SITE MAP ram, ^1� 4k LEGAL DESCRIPTION PARCEL NUMBER: 00580700002902 r Edmonds -Dispensary... Doyle Sails Seattle McDonald 'si® / Q Foreit Fast Food • S Q Used a Seattle Coffe - Repair QCarter Acura ofLynnwood ® Acura dealer V6111h St SW 216th St SW / 9INDUSTRIDUSS ®Sahm Gook Jih Pala e' Asian - S Jeff's Au epaJJJ' 99 Autorepaiysh0>p - gaming ew"y a Premer Denali I O LEGAL DESCRIPTION: SECTION 29 TOWNSHIP 27 RANGE 04 QUARTER NW - BLDGS ONLY ON FDP: THE W 331.60FT OF TR 29 EXC TH PTN OF TR 29 LY WLY OF FDL - COM AT NW COR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESCTH SLY TAP 35.44FT FR SW COR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005); REFER TO 00580700002901 FOR LAND APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work PLUMBING ................................................................................................................................ Address]7320 216TH ST SW Owner SWEDISH NUC Approved Date 01/17/2024 ................... ................................................................................................................ Building Official ErIiIIIlio& ....................................................... ............. Permit NumberBLD2024-0053 PLUMBING BASIS OF DESIGN ITEM # SYSTEM CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT 1-1 CODE 2018 INTERNATIONAL MECHANICAL CODE 1-2 CODE 2018 WASHINGTON STATE ENERGY CODE CODE COMPLIANCE 1-3 CODE 2018 UNIFORM PLUMBING CODE BASIS FOR PLUMBING DESIGN 2-1 DEMOLITION DEMO EXISTING HAND WASH SINK AND CAP EXISTING UTILITIES (COLD WATER, HOT WATER, SANITARY/VENT) FOR RECONNECTION. DESIGN APPROACH 2-2 NEW WORK EXTEND UTILITIES (COLD WATER, HOT WATER, SANITARY/VENT) THROUGH WALL TO SERVE NEW HANDWASH SINK. DESIGN APPROACH 2-3 SYSTEM CAPACITY NO NEW ADDITIONAL CAPACITY ADDED TO ANY EXISTING DOMESTIC WATER OR SANITARY/VENT SYSTEM. SINK IS LIKE -FOR -LIKE REPLACEMENT. DESIGN APPROACH 2-4 SYSTEM TYPE ALL WATER CONNECTIONS/SANITARY CONNECTIONS ARE TO BE DOMESTIC. NO LAB OR SPECIALTY WASTE OR WATER PROVIDED AS PART OF THIS SCOPE. DESIGN APPROACH try ife Of Your Building McKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: RECEIVED Jan 16 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REGISTRATION: �39995 FOIST E'lik" SS�ONAL E� 2i 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: MI.CHURCH CHECKED: D. MA JOB N0: 124016 ISSUED ON: SHEET TITLE: PLUMBING LEGEND, ABBREVIATIONS, VICINITY MAP & B.O.D. SHEET NUMBER: PLUMBING SPECIFICATIONS PRESSURE TEST PROCEDURE SEISMIC IMPORTANCE IP INSULATION & JACKETING ID CATEGORY SERVICE DESCRIPTION MANUFACTURER, PRODUCT OR EQUAL MEDIA TEST PRESSURE DURATION CODE DCW, DHW DHWR, TW (POTABLE) DOMESTIC COLD WATER DOMESTIC HOT WATER TO 160OF DOMESTIC HOT WATER RECIRC TO 160OF TEMPERED WATER (60-100°F) PIPE IDENTIFICATION MARKER OPERATING PRESSURE SIZES THRU 2" PIPE MATERIAL JOINTS JOINTS JOINTS COUPLINGS FITTINGS FITTINGS VALVES - ISOLATION VALVES - ISOLATION (ALT) DOMESTIC HOT AND COLD WATER SERVICE COMPLY WITH NSF-61 AND NSF 372 WHITE LETTERING ON GREEN BACKGROUND WATER OR AIR (NOT FOR PLASTIC PIPE) 100% OF OPERATING PRESSURE 15 MINUTES OR MFG SPEC SPC CHAPTER 6 NSF 61 SPC APPENDIX A IAPMO INSTALLATION STANDARDS 1.0 PER S.E.0 SEE INSULATION SCHEDULE NO INSERTS AT HANGERS USE INSERTS AT CLAMPS INSERTS TO BE STYRENE UP TO 100 PSI; SET RELIEF TO 125 PSI COPPER TUBE TYPE L ASTM 688 PER SUBMITTAL PRESS -FIT MECHANICAL COMPRESSION - THREADED AT SPECIALTIES SWEAT: WATER BASED FLUX ASTM B813; LEAD FREE SOLDER ASTM B-321 SILVER BRAZED: PER UPC CHAPTER 6 COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM) COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM) CAST BRONZE -SWEAT- ASTM B584 - LEAD FREE - NSF 61 PRESS FIT LEAD FREE BRONZE BALL VALVE -FULL PORT-1/4 TURN - NSF 61 G & 372 SWEAT - LEAD FREE 2-PC BRONZE BALL VALVE -FULL PORT - 1/4 TURN - NSF 61G & 372 MILWAUKEE UPBA-48013; VIEGA PROPRESS-2971 or 2970; APOLLO 77VLF-100 MILWAUKEE UPBA-48513; APOLLO 77CLF-200 V SANITARY VENT - ABOVE GROUND SANITARY VENT - CAST IRON WHITE LETTERING ON GREEN BACKGROUND UP TO 5 PSI CAST IRON NO -HUB ASTM A 888 & CISPI 301 NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 CAST IRON DRAIN PATTERNS CISPI 301 PER SUBMITTAL PER SUBMITTAL WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION DO NOT USE AIR FOR PLASTIC PIPE TESTING VISUAL INSPECTION WITH NO LEAKS SPC CHAPTER 9 1.0 N/A PIPE IDENTIFICATION MARKER OPERATING PRESSURE ALL SIZES (1) PIPE MATERIAL JOINTS FITTINGS PER SUBMITTAL W SANITARY WASTE - ABOVE GROUND PIPE IDENTIFICATION MARKER SANITARY WASTE - CAST IRON WHITE LETTERING ON GREEN BACKGROUND UP TO 5 PSI CAST IRON NO -HUB ASTM A 888 AND CISPI 301 NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 CAST IRON DRAIN PATTERNS CISPI 301 WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION DO NOT USE AIR FOR PLASTIC PIPE TESTING VISUAL INSPECTION WITH NO LEAKS SPC CHAPTER 7 1.0 N/A OPERATING PRESSURE ALL SIZES (1) PIPE MATERIAL PER SUBMITTAL JOINTS PER SUBMITTAL FITTINGS PER SUBMITTAL ALL CODE ALL DOMESTIC WATER SYSTEM COMPONENTS SHALL MEET NSF STANDARD 61 ALL CODE ALL PLASTIC DRAINAGE SYSTEM COMPONENTS SHALL MEET NSF STANDARD 14 ALL CODE ALL CAST IRON DRAINAGE SYSTEM COMPONENTS SHALL BE TRADEMARKED WITH CAST IRON SOIL PIPE INSTITUTE AND BE LISTED BY NSF. ALL SPECIALTIES PLUMBING SPECIALTIES - APPLICABLE SPECIALTIES IDENTIFIED IN EACH ID CATEGORY IN -LINE VALVE - FACTORY SET - NSF-61 BRASS WITH NEOPRENE VALVE CORES 3/8" INLET CONNECTIONS BALANCING VALVE - THERMOSTATIC CIRCUIT SOLVER UNION ASSEMBLY WITH CHECK VALVE AND ISOLATION VALVES PETE'S PLUG PETERSON EQUIPMENT CO PETE'S PLUG 11 THERMOSTATIC MIXING VALVE - SINGLE POINT OF USE - ASSE 1070 CASH ACME 135, ZURN ZW3870XLT, APOLLO 34C, POWERS HYDROGUARD DEFINITIONS AMERICAN SOCIETY MECHANICAL ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS ELECTRIC RESISTANCE WELD FAHRENHEIT (TEMPERATURE) FEET OF HEAD (PRESSURE) FEMALE PIPE THREAD INCHES MERCURY (PRESSURE) INTERNATIONAL FUEL GAS CODE INTERNATIONAL MECHANICAL CODE MEDICAL NOT APPLICABLE NO -HUB CAST IRON NATIONAL PIPE THREAD POUNDS PER SQUARE INCH (PRESSURE) POLYVINYL CHLORIDE POLYVINYLIDENE FLUORIDE (PLASTIC PIPE) SCHEDULE (PIPE WALL THICKNESS) SCHEDULE STANDARD STANDARD WEIGHT SWEAT (SOLDERED JOINTS) UNDERWRITERS LABORATORY UNIFORM PLUMBING CODE WASHINGTON STATE ENERGY CODE ASME ASTM ERW F FT HD FPT HG IFGC IMC MED N/A NHCI NPT PSI PVC PVDF SCH SCH STD STD WT SWEAT UL UPC WSEC NOTES: 1. MCKINSTRY DOES NOT INSTALL 5" DWV. PLUMBING PIPE INSULATION SCHEDULE - WASHINGTON ENERGY CODE: 2018 INTERNATIONAL ENERGY CODE WITH WASHINGTON AMENDMENTS TABLE C403.10.3 SPECIFICATION: 220716 PLUMBING PIPING INSULATION PIPING TEMP RANGE THERMAL MEAN RATING INSULATION SYSTEM (Deg F) COND. TEMPERATURE MATERIAL <1" 1" TO <1-1/2" 1 1/2" TO 4" 4" - 8" OVER 8" NOTES DOMESTIC COLD WATER 40-60 0.21-0.27 75 MIDI 0.5 0.5 1.0 1.0 1.0 1, 2, 4,10, 11 DOMESTIC HOT WATER 105-140 0.21-0.28 100 MIDI 1.0 1.0 1.5 1.5 1.5 1, 2, 4, 5,10, 11 MPI: MINERAL WOOL PREFORMED PIPE INSULATION E: ELASTORMERIC CLOSED CELL INSULATION PF: POLYURETHANE FOAM CGPI: CELLULAR GLASS PIPE INSULATION CAL-SIL: CALCIUM SILICATE NOTES: 1. FOR PIPING CLAMPED TO UNISTRUT SUPPORTS, UTILIZE RIGID INSERTS WITH SHEETMETAL SHIELDS CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 2. FOR PIPING SUPPORTED FROM CLEVIS HANGERS, IF RIGID INSERTS ARE NOT UTILIZED THE INSULATION SHALL FULLY ENCLOSE THE HANGER AND BE SEALED AT THE TOP AROUND THE SUPPORT ROD; IF RIGID INSERTS ARE UTILIZED THE INSULATION SHALL BE CONTINUOUS THROUGH THE HANGER: INSERT MATERIAL TO BE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 3. DOMESTIC WATER PIPING AND WASTE DRAIN TRAPS EXPOSED TO OUTDOOR CONDITIONS SUCH AS THE GARAGE ENTRY AND FIRST GARAGE LEVEL BELOW GRADE SHALL BE HEAT TRACED AND INSULATED. 4. JACKETING: ALUMINUM ROLLED JACKETING (ARJ) APPLIED TO EXTERIOR PIPING INSULATION EXPOSED TO WEATHER (I.E. ROOFTOP PIPING). PVC JACKETING WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR (PUBLIC AREAS). 5. FOR PIPING SMALLER THAN 1 1/2 INCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. 6. PROVIDE INSULATION ON ALL HORIZONTAL PRIMARY AND OVERFLOW ROOF DRAINAGE BELOW THE ROOF DECK. WHERE THE HORIZONTAL RUN IS LESS THAN 15', PROVIDE INSULATION ON THE RISER DOWN THROUGH THE NEXT FLOOR BELOVI THE ROOF 7. DIRECT BURIED PIPING THAT CONVEYS FLUID AT OR BELOW 60 DEG F IS EXEMPT FROM INSULATION PER WSEC 8. DIRECT BURIED HEATING AND HOT WATER SYSTEM PIPING MAY REDUCE THICKNESS BY 1.5" BUT NOT TO A THICKNESS LESS THAN 1" 9. DOMESTIC HOT WATER WITH ONE WAY DISTRIBUTION TO FIXTURE THAT IS INSTALLED IN -SLAB PEX WITHIN A SMURF TUBE AND AIR BARRIER MEETS WASHINGTON STATE ENERGY CODE PER C404.E 10. FOR PIPING SMALLER THAN 1 1/2 INCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. 11. ASTM E 84 OR UL 723 TESTED TO FLAME SPREAD INDEX OF 25 AND SMOKE DEVELOPED INDEX OF NOT EXCEEDING 50 PLUMBING FIXTURE SCHEDULE TAG MODEL CONNECTION NOTES CW HW TEMP W V RWL ORL HS-1 HAND WASH SINK, WALL MOUNTED, 4" CENTER SET FIXTURE: FAUCET: DRAIN: TRAP: TRAP PRIMER: SAFETY COVER SUPPLIES: MIXING VALVE CARRIER:l ZURN Z5344, VITREOUS CHINA, WALL MOUNT, 20X18, 4" CENTER FAUCET HOLES ZURN Z812B4-XL-17F, 1.5 GPM AERATOR, SENSOR, WRISTBLADE HANDLES, GOOSENECK FAUCET, POLISHED CHROME FINISH ZURN Z8743 GRID STRAINER, BRASS WITH CHROME FINISH ZURN Z8701-PC-BX, 1-1/2" X 1-1/4", 17 GAUGE CHROME PLATED BRASS ZURN Z1021-WL, 1-1/2", 17 GAUGE CHROME PLATED BRASS ZURN Z8946-1-NT, TRAP AND SUPPLY STOP PROTECTORS, SATIN WHITE PVC RESIN 20" CHROME SUPPLIES W/ 1/2" NOM. X 3/8" COMP. ANGLE STOP AND ESCUTCHEON, LOOSE KEY ZURN ZW3870XLT AQUA -GUARD THERMOSTATIC MIXING VALVE, ASSE 1070 COMPLIANT ZURN 1200 SERIES 1/2 1/2 1-1/2 1-1/2 FOR ACCESIBLE USE, MOUNT FIXTURE TO MEET ADA AND LOCAL CODES OR APPROVED ALTERNATE OR APPROVED ALTERNATE USE AS REQUIRED OR APPROVED ALTERNATE OR APPROVED ALTERNATE NOTE: THE ABOVE DATA SHALL BE USED FOR PRELIMINARY ELECTRICAL, STRUCTURAL OR ARCHITECTURAL COORDINATION ONLY. USE APPROVED MANUFACTURER'S SUBMITTAL DATA FOR CONSTRUCTION. SPP = SIZE PER PLANS. ff try ife Of Your Building MCKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: RECEIVED Jan 16 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REGISTRATION: P�7�x\' oFof STE 9995 �qNA%- / r '�7. 29 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: SPECIFICATIONS & SCHEDULES SHEET NUMBER: Pm002 1 1 PLUMBING DEMO PLAN P-111 I SCALE: 1/4" = V-0" GENERAL NOTES 1. DEMO & NEW WORK SHOWN BOLD 2 PLUMBING NEW WORK PLAN P-111 SCALE: 1/4" = V-0" KEYNOTES P1 DEMO EXISTING HANDWASH SINK. CAP UTILITIES FOR RECONNECTION. P2 INSTALL NEW HANDWASH SINK. EXTEND UTILITIES (DOMESTIC HOT/COLD WATER, WASTE/VENT) THROUGH WALL TO NEW SINK. P3 PROVIDE NEW SINK WITH NEW ASSE-1070-COMPLIANT THERMOSTATIC MIXING VALVE PER SCHEDULE AND ADA-COMPLIANT PIPE COVERS PER SPECIFICATIONS MATRICES. a try (: ife Of Your Building McKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: RECEIVED Jan 16 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REGISTRATION: 29 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: PLUMBING DEMO & NEW WORK PLANS SHEET NUMBER: