BLD2023-0825+Architectural_Plan+6.30.2023_2.28.00_PM+3643514
1 1 2 3 4 5 6 7 1 8 9 10 11 Ra x 0 LL w 0 U Im a a SHEET INDEX ARCHITECTURAL A0.00 COVER SHEET A1.01 PLANS -LEVEL 1 MECHANICAL SWEDISH EDMONDS M-001 MECHANICAL LEGEND, MAP, B.O.D & ABBREVIATIONS M-111 MECHANICAL FLOOR PLAN PLUMBING P-002 SPECIFICATIONS & SCHEDULES P-111 PLUMBING DEMO & NEW WORK PLANS NUC MED EQUIPMENT P-001 PLUMBING LEGEND, MAP, B.O.D. & ABBREVIATIONS ELECTRICAL E0.02 SINGLE LINE DIAGRAM & LOAD SUMMARY E0.03 LUMINAIRE SCHEDULE E1.01 FIRST FLOOR ELECTRICAL FLOOR PLANS E2.01 ELECTRICAL SPECIFICATIONS REPLACEMENT E0.01 ELECTRICAL LEGENDS & NOTES VENDOR Al ARCHITECTURAL LAYOUT E1 ELECTRICAL LAYOUT S1 STRUCTURALLAYOUT EDMONDS MEDICAL PAVILION 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 CONSTRUCTION DOCUMENTS PROJECT NOTES PROJECT TEAM VICINITY MAP PROJECT INFORMATION 1. THESE DRAWINGS AND THE ACCOMPANYING SPECIFICATIONS ARE THE PROPERTY OF TGB ARCHITECTS AND ARE NOT TO BE COPIED OR REUSED FOR ANY OTHER PROJECT. BUILDING OWNER: OWNER CONTACT: JEN PAYTON - • McDonald's® a' Fast Food-S SCOPE OF WORK 2. DRAWINGS HAVE BEEN PREPARED FROM DATA AND DRAWINGS PROVIDED BY THE OWNER TO THE ARCHITECT. THE ARCHITECT HAS VERIFIED EXISTING CONDITIONS TO THE BEST OF THEIR ABILITY. THE ARCHITECT ISSUES NO WARRANTY, NEITHER EXPRESSED NOR IMPLIED, FOR THE ACCURACY OR COMPLETENESS OF THE INFORMATION INDICATED HEREIN. HEALTHCARE REALTY 901 BOREN AVNUE, SUITE 110 SEATTLE, WA 98104 CONTACT PHONE JPAYTON@HEALTHCAREREALTY.COM QLodestar v 0 EDMON DS MEDICAL 9 Canopy World Truck accessories store u CarterAcul ofLynra e°` PAVILION Cogir of Edm nds REPLACEMENT OF EXISTING NUC MED EQUIPMENT, INCLUDING ASSOCIATED MECHANICAL (HVAC), ELECTRICAL, AND PLUMBING SYSTEMS. NO STRUCTURAL WORK. NO EXTERIOR WORK. APPROX 160 SQ FT Q� Assisted Lmng nd.s9 3. NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF EXISTING CONDITIONS THAT ARE CONTRARY TO THOSE REPRESENTED WITHIN THE TENANT: TENANT CONTACT: Stevens Court ApartmentsQ ° LEGAL DESCRIPTION DRAWINGS OR WHERE DIMENSIONS VARY GREATER THAN 2" THAN THOSE SHOWN IN DRAWINGS. 4. CONTRACTOR TO COORDINATE REQUIREMENTS FOR INFECTION CONTROL DURING COURSE OF CONSTRUCTION WITH OWNER PRIOR TO COMMENCEMENT OF WORK. PROVIDENCE SWEDISH 1321 COLBY AVE. EVERETT, WA 98201 JIM GRAFTON (425) 218 0919 JAMES.GRAFTON@PROVIDEN CE.ORG s° • Swedish ©216thStSW 216thStSW Edmonds Campus Surgical center Swedish Urgent p Edm nds Care - Edmonds QINDUSTRIOUS © THE WEST 331.60 FEET OF TRACT 29, SOLNER'S 5 ACRE TRACTS, ACCORDING TO THE PLAT THEROF RECORDED IN VOLUME 7 OF PLATS, PAGE 25, IN SNOHOMISH COUNTY, WASHINGTON Pavilion Q 5. PROVIDE 24" SQUARE ACCESS PANELS OR OF SIZES REQUIRED WHERE PLUMBING AND HEATING VALVES, WATER SWITCHES, OXYGEN PRESSURE SWITCHES, VENTILATION SPUTTER DAMPERS, ETC. ARE SHOWN ON PLUMBING AND MECHANICAL DRAWINGS. SUCH ACCESS PANELS TO BE INSTALLED IN THE FOLLOWING:A) GWBBOARD CEILINGS) METAL STUD AND MASONRY PARTITIONS. ARCHITECT: PROJECT LEAD: GINA DAIS 0 ®Sahm Gook Jih Palace y Puget Sound Qp Q Asian•$ Cancer Center TAX PARCEL NUMBER 5807-000-029-01-00 6. WALL ASSEMBLIES MUST BE MAINTAINED AT ALL RECESSED FIRE EXTINGUISHER CABINETS AND ALL RECESSED EQUIPMENT. TGB ARCHITECTS 21911 76TH AVE W, SUITE 210 PRINCIPAL IN CHARGE: KENT GREGORY 425-778-1530 GDAIS@TGBArchitects.com ealthCenterQ QEdmonds Oral Jeff's Auto Re Facial Surgery *Book an Appoi tment air AUTHORITY HAVING JURISDICTION (AHJ) EDMONDS, WA 98026 Q 7. PROVIDE FIRE EXTINGUISHER CABINETS OF THE TYPE SPECIFIED. REFER TO FLOOR PLAN(S) FOR LOCATIONS. 8. ALL SHAFT PARTITIONS EXTEND FROM FLOOR SLAB TO UNDERSIDE OF SLAB ABOVE. EXPOSED BEAMS WITHIN SHAFTS ARE TO BE FIREPROOFED MECHANICAL ENGINEER: MECHANICAL ENGINEER CONTACT: Edmonds Family Dentistry eParadiseEspr sso rn ©Edmonds Dentist- s Edmonds Family Dent,. CITY OF EDMONDS APPLICABLE CODES WITH 2-HOUR GWBBOARD ENCLOSURE. 9. THE FIRE RATINGS OF ALL FIRE RATED PARTITIONS WILL BE STENCILED ABOVE CEILINGS, EACH SIDE OF PARTITIONS, BOTH SIDES OF CORRIDORS McKINSTRY 5005 THIRD AVE SOUTH ALLISON KIDWELL 206-578-3370 ALLISONCO@MCKINSTRY.COM � Ellie Javadi, DDS, MSD, >D ©orached Periodontics and nt Specialist Dick's Drive -In ramburger•S® _ NORTH BUILDING CODE: WA STATE BUILDING CODE (IBC WITH AMENDMENTS) - 2018 EXISTING BUILDING CODE: WA STATE EXISTING -BUILDING CODE (IEBC WITH AMENDMENTS) 2018 ENERGY CODE: WA STATE ENERGY CODE WITH AMENDMENTS) 2018 AND AS REQUIRED BY AUTHORITY HAVING JURISDICTION. SEATTLE, WA 98134 Premier Therapy Associates q0 WinCo Foods CESCOMedical ® © 0••_ I � (IECC - LIFE SAFETY CODE: NFPA 101 - 2012 FIRE CODE: INTERNATIONAL FIRE CODE 2018 10. ALL GWB IS 5l8" TYPE'X' UNLESS NOTED OTHERWISE. �® ---- (IFC ) MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE (IMC) - 2018 11. THE DRAWINGS AND THE SPECIFICATIONS ARE COMPLEMENTARY. WHATEVER IS INDICATED IN ONE IS ASSUMED TO BE INDICATED IN THE OTHER. NOTIFY THE ARCHITECT IN CASE OF DISCOVERED DISCREPANCIES. ELECTRICAL ENGINEER: ELECTRICAL ENGINEER CONTACT: LEO MAYA PLUMBING CODE: UNIFORM PLUMBING CODE (UPC) - 2018 ELECTRICAL CODE: NATIONAL ELECTRICAL CODE (NEC) - 2020 DESIGN WEST ENGINEERING 425-458-9700 X 212 ACCESSIBILITY CODE: ANSI Al17.1 2009 (BY REFERENCE FROM IBC AND WSBC) 12. ALL SUBSTRATES ARE TO BE SMOOTH PRIOR TO INSTALLATION OF FINISHES. 110 JAMES ST SUITE 106 EDMONDS, WA 9802o LMAYA@DESIGNWESTENG.COM 13. ALL WORK AND MATERIALS TO CONFORM TO FACILITY STANDARDS. DEFERRED SUBMITTALS 1. FIRE SUPPRESSIONS SYSTEM GENERAL CONTRACTOR: GENERAL CONTRACTOR CONTACT: 2. FIRE ALARM DPR CONSTRUCTION JEFF ASAVALERTPANICH 650-863-6280 315 2ND AVE S SEATTLE, WA 98104 JEFFAS@DPR.COM VENDOR: VENDOR CONTACT: SPECTRUM DYNAMICS MEDICAL MATT WRUBLEWSKI 941-256-3541 EXT 4604 301 N CATTLEMEN ROAD SARASOTA, FL 34232 MATTW@SPECTRUM-DYNAMICS.COM tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 3626 REGISTERED ARCHITECT L. KENT GREGORY STATE OF WASHINGTON SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT EDMONDS MEDICAL PAVILION 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 CONSTRUCTION DOCUMENTS COVER SHEET ISSUANCE No. Description Date 1 CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: SHEET NO A0.00 ,)Ilnnn 1 2 3 4 5 6 7 8 7 10 11 2 3 4 61 6 7 8 x U U_ w 0 U _ — a 75 Cn 7 z a� 00 0 0 co CV N N OCM m C 0 co 0 0 a a� v Z s N co 0 o co fV a 75 ti N co N O co N O N O M cc DEMO CASEWORK AS INDICATED IN RED DASHED LINES DEMO CEILING TILES, GRID TO REMAIN DEMO FLOOR AND WALL BASE UNDER SEPARATE CONTRACT. COORDINATE WITH SWEDISH / CBRE NORTH FLOOR PLAN - LEVEL 1 - DEMO NEW 24" SURFAC PATCH/F NEEDED PAINT Al MATCH FLOOR PLAN - LEVEL 1 - NEW LIFE SAFETY FLOOR PLAN - LEVEL 1 1/16" = l'-0" EXISTING COUNTERTOP AND EDGE TO BE RE -LAMINATED COLOR:TBD PATCH/REPAIR WALLS AS NEEDED PAINT ALL WALLS TO MATCH EXISTING ADJUSTABLE HEIGHT DESK, NIC MOBILE WORK STATION, NIC FLOORING AND WALL BASE UNDER SEPARATE CONTRACT. COORDINATE INSTALL WITH SWEDISH / CBRE NUC MED MACHINE, COORD WITH VENDOR DRAWINGS PATCH/REPAIR WALLS AS NEEDED PAINT ALL WALLS TO MATCH EXISTING REPLACE LIGHT SWITCH WITH NEW DIMMER SWITCH REPLACE LIGHT SWITCH WITH NEW DIMMER SWITCH TECH I qORK AF x N C MED 1-11-1 �_l I � � �� REPLACE EXISTING CFL WITH NEW LED NEW UNDER COUN' LIGHT AT EXISTING UPPER CABINET 9 10 EXISTING BUILDING INFORMATION 1. MAIN OCCUPANCY - B-BUSINESS 2. CONSTRUCTION TYPE - IIA 3. NUMBER OF STORIES - 3-STORIES, PLUS BASEMENT 4. FULLY SPRINKLERED - COMPLYING WITH WSBC SECTION 903.3.1 AREA OF WORK N NORTH 9 EXISTING CAMERA REPLACE EXISTING CFL WITH NEW LED REPLACE ALL CEILING TILES IN ROOM WITH ARMSTRONG ULTIMA SQUARE LAY -IN, GRID TO REMAIN EXISTING COVER PLATE REPLACE EXISTING LIGHTS WITH NEW LED; DECORATIVE LENS TO BE REINSTALLED REPLACE EXISTING CFL WITH NEW LED NORTH NORTH CEILING PLAN - LEVEL 1 - NEW 1 /4" = 1'-0" \� 1 /4" = l'-0" \�,� 1 /4" = l'-0" FLOOR PLAN NOTES 1. FLOOR PLANS MAY NOT INCLUDE TOTAL OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR ANY CABINETS, EQUIPMENT, HANDRAILS, OR WHERE REQUIRED. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 3626 V'_� REGISTERED RCHITECT L. KE T GR G STATE OF WASHINGTON SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT EDMONDS MEDICAL PAVILION 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 CONSTRUCTION DOCUMENTS PLANS- LEVEL 1 ISSUANCE No. Description Date 1 CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: 23008 PROJECT LEAD: Designer DRAWN BY: Author SHEET NO 1 2 3 1 4 5 1 6 7 1 8 9 1 10 11 ABBREVIATIONS GENERAL AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AFC ABOVE FINISHED GRADE BHP BRAKE HORSEPOWER BOP BOTTOM OF PIPE BOT BOTTOM C/L CENTER LINE CLG CEILING CFM CUBIC FEET PER MINUTE CO CARBON MONOXIDE CO2 CARBON DIOXIDE CSR CURRENT SENSING RELAY DISCH DISCHARGE DN DOWN DS DISCONNECT SWITCH; DOOR SWITCH (E) EXISTING EA EACH EC ELECTRICAL CONTRACTOR; END CAP EP ELECTRICAL PANEL; END PLUG EPO EMERGENCY POWER OFF ESP EXTERNAL STATIC PRESSURE (F) FUTURE FA FIRE ALARM FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FLEX FLEXIBLE FLR FLOOR FP FIRE PROTECTION FTG FOOTING GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR HP HORSEPOWER; HIGH PRESSURE HTG HEATING HTR HEATER IAW IN ACCORDANCE WITH ID INSIDE DIAMETER/DIMENSION IN WC INCHES WATER COLUMN MC MECHANICAL CONTRACTOR MFR MANUFACTURER MH MANHOLE MTD MOUNTED N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN; NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OVHD OVERHEAD PERF PERFORATED POC POINT OF CONNECTION QTY QUANTITY (R) RELOCATED RCP REFLECTED CEILING PLAN REQD REQUIRED SECT SECTION SIM SIMILAR SPEC SPECIFICATION STD STANDARD TBD TO BE DETERMINED TI TENANTIMPROVEMENTS TOC TOP OF CONCRETE TOS TOP OF STEEL TSP TOTAL STATIC PRESSURE TYP TYPICAL UG UNDERGROUND LINO UNLESS NOTED OTHERWISE VFD VARIABLE FREQUENCY DRIVE VSD VARIABLE SPEED DRIVE W/ WITH W/o WITHOUT WC WATER COLUMN WIG WATER GAUGE HVAC AC AIR CONDITIONING AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT CC COOLING COIL CRU COMPUTER ROOM UNIT CT COOLING TOWER CV CONSTANT VOLUME DB DUCT BOARD DIFF DIFFUSER DMPR DAMPER EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECG EGGCRATE GRILLE EF EXHAUSTFAN FCU FAN COIL UNIT FD FIRE DAMPER FM FREQUENCY MODULATION FP FIRE PROTECTION; FAN POWERED FSD COMBINATION FIRE/SMOKE DAMPER FTU FAN TERMINAL UNIT GRID GRILLE, REGISTER, DIFFUSER HC HEATING COIL HVAC HEATING, VENTILATION AND AIR CONDITIONING LAT LEAVING AIR TEMPERATURE LID LINEAR DIFFUSER MA MIXED AIR MOD MOTOR OPERATED DAMPER; MODULATING MAU MAKE-UP AIR UNIT MUA MAKE-UP AIR OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER RA RETURN AIR RAT RETURN AIR TEMPERATURE RTU ROOF TOP UNIT SA SUPPLY AIR SAT SUPPLY AIR TEMPERATURE SD SMOKE DAMPER; SMOKE DETECTOR SF SUPPLY FAN SL SOUND LINED SLSM SOUND LINED SHEET METAL SM SHEET METAL SO SCREENED OPENING SP STATIC PRESSURE TG TRANSFER GRILLE TOD TOP OF DUCT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER PIPING BD STEAM BLOWDOWN BP BACKFLOW PREVENTER CA COMPRESSED AIR CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CLPS CLEAN LOW PRESSURE STEAM CNDS CONDENSATE CNDWR CONDENSER WATER RETURN CNDWS CONDENSER WATER SUPPLY DRAIN TANK OVERFLOW & DRAINS DTR DUAL TEMPERATURE RETURN DTS DUAL TEMPERATURE SUPPLY EWT ENTERING WATER TEMPERATURE FCD FLUE CONDENSATE DRAIN FEED BOILER FEED WATER FOF FUEL OIL FILL FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOV FUEL OIL VENT G NATURAL GAS 2# G NATURAL GAS - LOW PRESSURE, 2 PSI 5# G NATURAL GAS - LOW PRESSURE, 5 PSI GE GENERATOR EXHAUST GFWR GEO - FIELD WATER RETURN GFWS GEO - FIELD WATER SUPPLY GWR GROUND WATER RETURN GWS GROUND WATER SUPPLY HPC HIGH PRESSURE CONDENSATE HPS HIGH PRESSURE STEAM HWR HEATING WATER RETURN HWS HEATING WATER SUPPLY LPC LOW PRESSURE CONDENSATE LPG LIQUEFIED PROPANE GAS LPS LOW PRESSURE STEAM LWT LEAVING WATER TEMPERATURE MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM PCW PROCESS COLD WATER PCWR PROCESS COOLING WATER RETURN PCWS PROCESS COOLING WATER SUPPLY PHW PROCESS HOT WATER PHWR PROCESS HOT WATER RETURN RL REFRIGERATION LIQUID IRS REFRIGERATION SUCTION RV REFRIGERATION VENT SCW SOFTENED COLD WATER SRV STEAM RELIEF VENT TOP TOP OF PIPE PIPING IDENTIFICATION HVAC RETURN PIPING SUPPLY PIPING PIPING FITTINGS TEE UP TEE DOWN TEE DN W/ ELBOW TEE UP W/ ELBOW 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW REDUCER SLOPE SYMBOL BREAK OR CONTINUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT VALVES MOTORIZED 2-WAY VALVE MOTORIZED 3-WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3-WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VALVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3-WAY GATE VALVE PLUG VALVE BALANCING VALVE HOSE BIBB AUTO FLOW VALVE PIPING ACCESSORIES DUCTWORK ACCESSORIES FID F D S FSD FSD AD AD 12x12 XSL R PROJECT SPECIFIC SUPPLY GRILLE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEILING APPURTENANCES FLEX CONNECTION FIRE DAMPER THROUGH WALL FIRE DAMPER THROUGH FLOOR FIRE/SMOKE DAMPER THROUGH WALL FIRE/SMOKE DAMPER THROUGH FLOOR ACCESS DOORS ACOUSTICALLY LINED DUCT (X" THICK SOUND LINING) CHANGE OF ELEVATION RISE(R) DROP(D) TURNING VANES RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR PUMP QMV AV MANUAL AIR VENT DUCTWORK Q HAV AUTOMATIC AIR VENT Q II HIGH CAPACITY AIR VENT RECTANGULAR DUCT 4 SUPPLY AIR DUCT SHOCK ARRESTOR TURNING UP OR TOWARD FS RECTANGULAR DUCT Q FLOW SWITCH SUPPLY AIR DUCT VACUUM BREAKER TURNING DOWN OR AWAY Q RECTANGULAR DUCT PRESSURE GAUGE RETURN AIR DUCT TEMPERATURE SENSOR TURNING UP OR TOWARD 4 RECTANGULAR DUCT TEMPERATURE INDICATOR RETURN AIR DUCT FM TURNING DOWN OR AWAY FLOW METER RECTANGULAR DUCT Y STRAINER W/ BALL VALVE EXHAUST AIR DUCT TURNING UP OR TOWARD PIPE SLEEVE RECTANGULAR DUCT STEAM TRAP EXHAUST AIR DUCT PETES PLUG TURNING DOWN OR AWAY T ROUND DUCT SUCTION DIFFUSER W/ STRAINER SUPPLY AIR DUCT f�CrDr REDUCED PRESSURE TURNING UP OR TOWARD BACKFLOW PREVENTOR ROUND DUCT SUPPLY AIR DUCT I lX TURNING DOWN OR INSTRUMENTATION AND CONTROLS AWAY ROUND DUCT / RETURN AIR DUCT THERMOSTAT TURNING UP OR TOWARD Sa SENSOR ROUND DUCT RETURN AIR DUCT CO CARBON MONOXIDE SENSOR TURNING DOWN OR CO2 CARBON DIOXIDE SENSOR AWAY ROUND DUCT OCC OCCUPANCY SENSOR EXHUAST AIR DUCT 1) TURNING UP OR TOWARD SD SMOKE DETECTOR ROUND DUCT Iy EXHAUST AIR DUCT GENERAL INFORMATION SYMBOLS TURNING DOWN OR AWAY NEW MECHANICAL WORK OVAL DUCT L___8SUPPLY AIR DUCT FUTURE TI SCOPE & NEW WORK OTHER THAN MECHANICAL TURNING UP OR TOWARD OVAL DUCT POINT OF CONNECTION X SUPPLY AIR DUCT POINT OF DEMOLITION TURNING DOWN OR AWAY (10 CL CENTERLINE MMM FLEXIBLE DUCT ) XO KEY NOTE REFERENCE X PIPING RISER CALLOUT (CHW; HW) X PIPING RISER # X PLAN NUMBER X SHEET NUMBER WHERE PLAN SHOWN X DETAIL OR DIAGRAM NUMBER X SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN X SECTION LETTER X SHEET NUMBER WHERE SECTION SHOWN X REVISION NUMBER - DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED c:::: REVISION CLOUD - DENOTES AREA OF CHANGE X - - X DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION GRILLE/REGISTER/DIFFUSER PROJECT SPECIFIC CEILING SUPPLY AIR DIFFUSER CEILING RETURN GRILLE OR TRANSFER AIR GRILLE CEILING EXHAUST GRILLE LINEAR DIFFUSER (CEILING) 0 LINEAR DIFFUSER (WALL) LOUVER PLAN VIEW LOUVER (ELEVATION VIEW) HVAC - ANNOTATION EQUIPMENT / LOUVER TAG EF EQUIPMENT 2-1 DESIGNATION CONSECUTIVE EQUIPUIPMENT # FLOOR OF EQUIP. LOCATION GRILLE, REGISTER, OR DIFFUSER TAG TYPE CODE WIDTH FF___HEIGHT CFM GENERAL NOTES 1. ENTIRE INSTALLATION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE UNIFORM PLUMBING CODE 2018, WASHINGTON STATE BUILDING CODE 2018, INTERNATIONAL BUILDING CODE 2018, WASHINGTON STATE ENERGY CODE (WSEC) 2018, AND ALL OTHER APPLICABLE CODES AND REGULATIONS. 2. INTERRUPTIONS OF SERVICES (POWER, WATER, HVAC, ETC.) AND WORK IN OCCUPIED TENANT SPACES MUST BE SCHEDULED THROUGH THE BUILDING MANAGER A MINIMUM OF 24 HOURS IN ADVANCE. ANY INTERRUPTIONS OR CONSTRUCTION WHICH WILL AFFECT NORMAL OPERATION OF THE BUILDING OR TENANTS MUST BE SCHEDULED, WITH THE BUILDING MANAGER'S APPROVAL, ON AN AFTER-HOURS BASIS. 3. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY COOLING DURING CONSTRUCTION. PERMANENT MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY COOLING WITHOUT PROTECTION FROM DUST ACCUMULATION, WRITTEN ACCEPTANCE OF DUST RELATED WARRANTY COSTS, AND PRIOR APPROVAL BY THE MECHANICAL ENGINEER. 4. FURNISH LABOR, MATERIALS, EQUIPMENT, APPARATUS, AND APPURTENANCES REQUIRED FOR A COMPLETE WORKING AND COORDINATED SYSTEM. MATERIALS, EQUIPMENT, APPARATUS, AND APPURTENANCES SHALL MATCH EXISTING BUILDING STANDARDS IN QUALITY, TYPE AND FINISH, UNLESS OTHERWISE NOTED. 5. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT. COORDINATE THE EXACT LOCATIONS OF NEW MECHANICAL AND PLUMBING EQUIPMENT WITH THE LOCATIONS OF LIGHTING FIXTURES, PIPING, AND OTHER CONSTRUCTION, TO ALLOW FOR PROPER ACCESS TO SERVICE AND MAINTAIN EQUIPMENT PRIOR TO START OF CONSTRUCTION. 6. COORDINATE THE LOCATION OF DUCTWORK AND PIPING WITH OTHER TRADES. PROVIDE OFFSETS IN DUCTWORK AND PIPING AS REQUIRED AT NO ADDITIONAL COST TO OWNER. 7. TRADES TO LEAVE 36" CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 8. INSTALL DUCTWORK AND PIPING TO ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF THE ELECTRICAL CABLE TRAYS. 9. SUPPORT CONDUIT, PIPING, AND DUCTWORK INDEPENDENTLY. SUPPORTS ARE INDEPENDENT OF PARTITION AND CEILING SYSTEM SUPPORTS. 10. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT, DUCTWORK, OR PIPING. 11. CUTTING, FRAMING, PATCHING, AND PAINTING OF WALL, CEILING, AND FLOOR OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. THIS INCLUDES OPENINGS THROUGH AREA SEPARATION WALLS 12. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON, I.E. ANCHOR BOLT DEPTHS, ETC. 13. REFER TO STRUCTURAL DRAWINGS FOR EQUIPMENT SUPPORTS. REFER TO THE SPECIFICATIONS MATRIX FOR ADDITIONAL SEISMIC INFORMATION. 14. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY MCKINSTRY ENGINEERING FOR COORDINATION. 15. PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE INTERNATIONAL BUILDING CODE FOR DUCTWORK, PIPING, AND EQUIPMENT. 16. FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURAL INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIED SESISMIC DESIGN INFORMATION SHEET 17. CONCRETE EQUIPMENT CURBS, FLASHINGS, SLEEPERS, CONCRETE STATIONS, EMBED PLATES, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. 18. CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. 19. SLEEPERS, HOUSEKEEPING PADS, EMBED PLATES, AND CANT STRIPS SHALL BE BUILT AND FASTENED TO THE ROOF BY THE GENERAL CONTRACTOR. TOP OF THE CURB MUST BE FLAT TO PROVIDE AN ACCEPTABLE SEALING SURFACE. MAXIMUM ALLOWABLE DEVIATION FROM LEVEL SHALL BE 1/4' IN 10'. ROOF CURBS AND SLEEPERS MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 20. LOUVERS, BOTH DUCTED AND NON -DUCTED, ARE TO BE FURNISHED AND INSTALLED BY McKINSTRY. LOUVERS ARE SHOWN ON THESE PLANS BOTH FOR COORDINATION, AND TO INDICATE THE REQUIRED LEVEL OF PERFORMANCE. LOUVERS OF ALTERNATE MAKE AND/OR TYPE MAY BE SUBSTITUTED ONLY IF THEY HAVE BOTH PRESSURE DROP AND WATER CARRY-OVER PERFORMANCE EQUAL TO OR BETTER THAN THE LOUVERS SPECIFIED. LOUVERS MUST CONTAIN THE FREE AREA REQUIREMENT INDICATED ON THE MECHANICAL PLANS. OTHER LOUVER MODELS WITH EQUAL OR BETTER FREE AREA, WATER CARRY-OVER, AND PRESSURE DROP MAY BE SUBSTITUTED IF APPROVED BY THE MECHANICAL ENGINEER AND ARCHITECT. 21. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. 22. PROVIDE ACCESS DOORS IN WALLS AND CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED MECHANICAL OR PLUMBING EQUIPMENT, VALVES, CONTROLS, AND OTHER DEVICES. 23. PROVIDE PIPE, EQUIPMENT, AND VALVE LABELING FOR IDENTIFICATION. MATCH OWNERS EXISTING LABELING SCHEME IF APPLICABLE. 24. SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR PLENUMS. 25. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 26. PROVIDE FIRE SAFE PENETRATIONS OF FIRE RATED CONSTRUCTION. 27. VARIABLE PITCH SHEAVES TO BE USED FOR SYSTEM BALANCING. REPLACE WITH FIXED PITCH SHEAVES FOR NORMAL OPERATION. 28. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 29. ALL SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN DRAWINGS, SPECIFICATIONS, SECTIONS C403.10.1.1 AND C403.10.3, TABLES C403.10.1.1 AND C403.10.3 OF THE 2018 WSEC, WHICHEVER IS MOST STRINGENT. 30. VENTILATION RATES SHALL COMPLY WITH OR EXCEED THE 2018 WSEC. 31. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS SPECIFICALLY MARKED AS EXISTING, EXISTING TO REMAIN, EXIST., OR (E). MECHANICAL INDEX SHEET NO. SHEET NAME M-001 MECHANICAL LEGEND, MAP, B.O.D. & ABBREVIATIONS M 111 MECHANICAL FLOOR PLAN VICINITY MAP e`� Edmonds- Dispensary Doyle Sails Seattle SK. & .. 215th St SW 215th St SW 21 Sth St ab Health / Rehab Center � Q McDonald's � O Foreic v Fast Food • S / Used d Q Seattle Coffe A - Repair Carter Acura Swedish Medical Cogir of Edmonds of Lynnwood ' Center Edmonds... Q a /,�`' Acura dealer c, shop Assisted Living and... B 8 Q Stevens Court Apartments Q 8 F Affairs 2 r s s Swedish Swedish Urgent 216th St sw 216th St SW e Clinic O Edmonds Campus Care - Edmonds / Q / INDUSTRIOUS // ® on Q • / o VAs,a - S ook Jih Palac Puget Sound e Cancer Center Steven's Health Center Q QEdmonds Oral & Jeffs Aut epa' Facial Surgery Auto repai hop drew PerryQ iq Puget Sound Hearing Aid - & Audiology - Edmonds Hearing aid store 9Paradise spress0 218th St SW QEllie Javadi, DDS, MSD, stin Pagan, DDS, MSD Orchid Periodontics... g Premier TheDicHa Drive -In PY Hamburger • $ o Associates ine J. Bunnell, PAP Q 8 WinCOFoods9 © pCESCOMe scat a Medical supp score Premer Pathology Custom Dental Care EVgo Charging Station Denali I ociates Med Labe o QEye Clinic of Edmonds Cornerstone ®Red Dragon kerb Insurance Group ® casino for'abl eiectroCic gaming A Starbucks�, I 1 �r _rcal center Jill S'ugi 1 •d O S e • ea � l o •drnondS Or�thoapy • Ed onds OrthoPedlc Center i v � IL It W LEGAL DESCRIPTION PARCEL NUMBER: 00580700002902 LEGAL DESCRIPTION: SECTION 29 TOWNSHIP 27 RANGE 04 QUARTER NW - BLDGS ONLY ON FDP: THE W 331.60FT OF TR 29 EXC TH PTN OF TR 29 LY WLY OF FDL - COM AT NW COR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESCTH SLY TAP 35.44FT FIR SW COR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005); REFER TO 00580700002901 FOR LAND BASIS OF DESIGN ITEM # SYSTEM CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT 1-1 CODE 2018 INTERNATIONAL MECHANICAL CODE WASHINGTON STATE 1-2 CODE 2018 WASHINGTON STATE ENERGY CODE WASHINGTON STATE BASIS FOR LOAD CALCULATIONS EXISTING CONDITIONS, INTERNAL LOADS, ENVELOPE, ETC ARE ASSUMED TO BE THE SAME AS EXISTING, WITH THE EXCEPTION OF 2 1 LOAD CALCULATIONS DESIGN APPROACH THE ADDITION OF THE NUC MED EQUIPMENT (6800 BTU/HR HEAT GENERATION). 2-2 VENTILATION EXISTING VENTILATION RATES TO REMAIN UNCHANGED, WITH THE EXCEPTION OF NUC MED, WHICH WILL SLIGHTLY INCREASE. DESIGN APPROACH EXISTING HVAC CONDITIONS 3-1 OPERATING HOURS OFFICE SPACE HOURS: 6AM - 8PM ASSUMPTION EXISTING CENTRAL AIR HANDLER PROVIDES COOLING AND VENTILATION AIR TO FAN TERMINALS THAT SERVE THE AREA OF 3-2 AIR HANDLER WORK. PERIMETER FAN TERMINAL UNITS WITH ELECTRIC REHEAT PROVIDE HEATING FOR THE AREA OF WORK. AIR RETURNS TO EXISTING DRAWINGS THE AIR HANDLER VIA PLENUM RETURN. NUC MED SPACE IS SERVED OFF FAN -POWERED TERMINAL BOX VAV-1-3. SEVERAL OTHER SPACES ARE ALSO SERVED FROM THIS 3-3 ZONING EXISTING DRAWINGS TERMINAL UNIT. THE THERMOSTAT IS LOCATED IN A NEARBY OFFICE. - AIRFLOWS NOTED ON MECHANICAL PLANS ARE ACCURATE (W/IN 10%) OF ACTUAL CONDITIONS. PRE -TAB TO CONFIRM THIS ASSUMPTION. 3-4 CAPACITY ASSUMPTIONS DESIGN APPROACH - CURRENT CAPACITY OF MECHANICAL SYSTEM IS SUFFICIENT FOR EXISTING CONDITIONS. ADDITION OF NUC MED IS ONLY ADDITIONAL CAPACITY REQUIREMENT. BASIS FOR SCOPE OF WORK - REBALANCE/REPROGRAM AIRFLOW SETPOINTS FOR EXISTING FAN POWERED TERMINAL UNIT SERVING THE ZONE INCLUDING THE NUC MED SPACE TO THE TOTAL AIRFLOW NOTED ON DRAWINGS. 4-1 REBALANCING DESIGN APPROACH REBALANCE THE DIFFUSER IN NUC MED AS NOTED ON DRAWINGS. CONFIRM AND REBALANCE DIFFUSERS ON NUC MED ASSOCIATED ZONE AS INDICATED ON DRAWINGS. EXISTING THERMOSTAT FOR VAV-1-3 IS LOCATED IN ADJACENT OFFICE SPACE (NOT NUC MED). PER DISCUSSIONS WITH OWNER, OWNER HAS OPTED TO LEAVE THERMOSTAT IN CURRENT LOCATION. DESIGN APPROACH/OWNER 4-2 TEMPERATURE CONTROL - ZONE WILL CONTROL TO MAINTAIN THERMOSTAT SETPOINT IN ADJACENT OFFICE, NOT TO MAINTAIN A TEMPERATURE SETPOINT DIRECTION IN NUC MED SPACE. 4-3 CONTROLS EXISTING CONTROLS TO BE MAINTAINED. DESIGN APPROACH try ife Of Your Building T WKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstrv.com PROJECT SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: REGISTRATION: ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: MECHANICAL LEGEND, ABBREVIATIONS, VICINITY MAP & B.O.D. SHEET NUMBER: KEYNOTES C `M 0 J [ci rL�i�ikl PB-140 SUITE 10993.29 ft2 SURGERY CENTER ou GENERAL NOTES 1. NEW WORK SHOWN BOLD 2. FIELD VERIFY EXACT INTALL LOCATIONS VASChjj IJI In IMP r. Alm Irm !,I t1.7�'fil'� t•1 I ■ EL 0 PB-130 BLOOD DRAW 258.72 ft2 PB-110 ft2 CARD IV U m El STA F RR LL P�1 il SHAFT 66/4\ M1 TAB TO CONFIRM EXISTING AIRFLOW AT DIFFUSER MATCHES (W/IN 10%) CFM LISTED ON DRAWINGS. ONCE FAN TERMINAL UNIT HAS BEEN REBALANCED/REPROGRAMMED TO NEW MAX AIRFLOW, REBALANCE EXISTING DIFFUSER BACK TO SPECIFIED CFM. M2 ONCE FAN TERMINAL UNIT HAS BEEN REBALANCED/REPROGRAMMED TO NEW MAX AIRFLOW, REBALANCING EXISTING DIFFUSER TO SPECIFIED NEW AIRFLOW. M3 REBALANCING/REPROGRAM VAV BOX TO THE FOLLOWING AIRFLOWS: MAX FAN AIRFLOW: 1995 CFM MAX PRIMARY AIRFLOW: 1855 CFM ALL OTHER SETPOINTS TO REMAIN UNCHANGED. OFFICE (4 OFFICE C 110 CFM M1 OIL n L_�_115 CFM M1 195 CFM M1 -235 CFM M1 EXISTING OPEN - PLENUM RETURN 700 CFM M2 185 CFM M1 185 CFM M1 265 CFM M1 ry ife Of Your Building McKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstrv.com PROJECT SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: REGISTRATION: ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: ID.MA JOB NO: 124016 ISSUED ON: SHEET TITLE MECHANICAL FL PLAN 1 MECHANICAL PLAN M-111 SCALE: 1/8" = 1'-0" SHEET NUMBER: ABBREVIATIONS GENERAL AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AFC ABOVE FINISHED GRADE BHP BRAKE HORSEPOWER BOP BOTTOM OF PIPE BOT BOTTOM C/L CENTER LINE CLG CEILING CFM CUBIC FEET PER MINUTE CO CARBON MONOXIDE CO2 CARBON DIOXIDE CSR CURRENT SENSING RELAY DISCH DISCHARGE DN DOWN DS DISCONNECT SWITCH; DOOR SWITCH (E) EXISTING EA EACH EC ELECTRICAL CONTRACTOR; END CAP EP ELECTRICAL PANEL; END PLUG EPO EMERGENCY POWER OFF ESP EXTERNAL STATIC PRESSURE (F) FUTURE FA FIRE ALARM FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FLEX FLEXIBLE FLR FLOOR FP FIRE PROTECTION FTG FOOTING GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR HP HORSEPOWER; HIGH PRESSURE HTG HEATING HTR HEATER IAW IN ACCORDANCE WITH ID INSIDE DIAMETER/DIMENSION IN WC INCHES WATER COLUMN MC MECHANICAL CONTRACTOR MFR MANUFACTURER MH MANHOLE MTD MOUNTED N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN; NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OVHD OVERHEAD PERF PERFORATED POC POINT OF CONNECTION QTY QUANTITY (R) RELOCATED RCP REFLECTED CEILING PLAN REQD REQUIRED SECT SECTION SIM SIMILAR SPEC SPECIFICATION STD STANDARD TBD TO BE DETERMINED TI TENANTIMPROVEMENTS TOC TOP OF CONCRETE TOS TOP OF STEEL TSP TOTAL STATIC PRESSURE TYP TYPICAL UG UNDERGROUND UNO UNLESS NOTED OTHERWISE VFD VARIABLE FREQUENCY DRIVE VSD VARIABLE SPEED DRIVE W/ WITH W/o WITHOUT WC WATER COLUMN WIG WATER GAUGE HVAC AC AHU BDD BOD CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FSD FTU GRID HC HVAC LAT LID MA MOD MAU MUA OA OBD RA RAT RTU SA SAT SD SF SL SLSM SM SO SP TG TOD VAV VD 91910116 BD BP CA CHWR CHWS CLPS CNDS CNDWR CNDWS DRAIN DTR DTS WITAI FCD FEED FOF FOR FOS FOV G 2# G 5# G GE GFWR GFWS GWR GWS HPC HPS HWR HWS LPC LPG LPS LWT MPC MPS PCW PCWR PCWS PHW PHWR RL IRS RV SCW SRV TOP AIR CONDITIONING AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DUCT BOARD DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUSTFAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED COMBINATION FIRE/SMOKE DAMPER FAN TERMINAL UNIT GRILLE, REGISTER, DIFFUSER HEATING COIL HEATING, VENTILATION AND AIR CONDITIONING LEAVING AIR TEMPERATURE LINEAR DIFFUSER MIXED AIR MOTOR OPERATED DAMPER; MODULATING MAKE-UP AIR UNIT MAKE-UP AIR OUTSIDE AIR OPPOSED BLADE DAMPER RETURN AIR RETURN AIR TEMPERATURE ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER; SMOKE DETECTOR SUPPLY FAN SOUND LINED SOUND LINED SHEET METAL SHEET METAL SCREENED OPENING STATIC PRESSURE TRANSFER GRILLE TOP OF DUCT VARIABLE AIR VOLUME VOLUME DAMPER STEAM BLOWDOWN BACKFLOW PREVENTER COMPRESSED AIR CHILLED WATER RETURN CHILLED WATER SUPPLY CLEAN LOW PRESSURE STEAM CONDENSATE CONDENSER WATER RETURN CONDENSER WATER SUPPLY TANK OVERFLOW & DRAINS DUAL TEMPERATURE RETURN DUAL TEMPERATURE SUPPLY ENTERING WATER TEMPERATURE FLUE CONDENSATE DRAIN BOILER FEED WATER FUEL OIL FILL FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL VENT NATURAL GAS NATURAL GAS - LOW PRESSURE, 2 PSI NATURAL GAS - LOW PRESSURE, 5 PSI GENERATOR EXHAUST GEO - FIELD WATER RETURN GEO - FIELD WATER SUPPLY GROUND WATER RETURN GROUND WATER SUPPLY HIGH PRESSURE CONDENSATE HIGH PRESSURE STEAM HEATING WATER RETURN HEATING WATER SUPPLY LOW PRESSURE CONDENSATE LIQUEFIED PROPANE GAS LOW PRESSURE STEAM LEAVING WATER TEMPERATURE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM PROCESS COLD WATER PROCESS COOLING WATER RETURN PROCESS COOLING WATER SUPPLY PROCESS HOT WATER PROCESS HOT WATER RETURN REFRIGERATION LIQUID REFRIGERATION SUCTION REFRIGERATION VENT SOFTENED COLD WATER STEAM RELIEF VENT TOP OF PIPE PIPING IDENTIFICATION HVAC PIPING FITTINGS D VALVES RETURN PIPING SUPPLY PIPING PIPING ACCESSORIES AV HAV r� J� fmCrDr TEE UP TEE DOWN TEE DN W/ ELBOW TEE UP W/ ELBOW 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW REDUCER SLOPE SYMBOL BREAK OR CONTINUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT MOTORIZED 2-WAY VALVE MOTORIZED 3-WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3-WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VALVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3-WAY GATE VALVE PLUG VALVE BALANCING VALVE HOSE BIBB AUTO FLOW VALVE PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR FLOW METER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP PETES PLUG SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR GENERAL INFORMATION SYMBOLS NEW MECHANICAL WORK FUTURE TI SCOPE & NEW WORK OTHER THAN MECH POINT OF CONNECTION POINT OF DEMOLITION CENTERLINE KEY NOTE REFERENCE PIPING RISER CALLOUT (CHW; HW) PIPING RISER # PLAN NUMBER SHEET NUMBER WHERE PLAN SHOWN DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN REVISION NUMBER - DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD - DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION GENERAL NOTES 1. ENTIRE INSTALLATION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE UNIFORM PLUMBING CODE 2018, WASHINGTON STATE BUILDING CODE 2018, INTERNATIONAL BUILDING CODE 2018, WASHINGTON STATE ENERGY CODE (WSEC) 2018, AND ALL OTHER APPLICABLE CODES AND REGULATIONS. 2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS SPECIFICALLY MARKED AS EXISTING, EXIST, OR (E). EXISTING WORK ON DRAWINGS SHALL BE NOTED IN HALFTONE. 3. REFER TO CIVIL DRAWINGS FOR UTILITY WORK 5-0" BEYOND THE BUILDING LINE. COORDINATE EXTERIOR PIPE INVERT ELEVATIONS WITH CIVIL ENGINEER. 4. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. 5. COORDINATE LOCATIONS OF ALL ROOF OPENINGS WITH STRUCTURAL, MECHANICAL, AND ARCHITECTURAL PLANS PRIOR TO ANY INSTALLATION. VENT THROUGH ROOF LOCATIONS SHALL MAINTAIN MINIMUM 15'-0" CLEARANCE WITH HVAC AIR INTAKES. 6. COORDINATE PLUMBING SYSTEMS AND EQUIPMENT SPACES WITH WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 7. PRIOR TO START OF INSTALLATION OF BELOW SLAB PIPING, COORDINATE LOCATIONS OF PIPING AND STRUCTURAL FOOTINGS, GRADE BEAMS, ETC. WITH STRUCTURAL ENGINEER. 8. COORDINATE ALL FLOOR AND WALL PENETRATIONS WITH STRUCTURAL ENGINEER PRIOR TO STARTING WORK. SUBMIT COMPLETE SLEEVE AND CORE DRILL PLANS TO STRUCTURAL ENGINEER FOR REVIEW. 9. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OF OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND SPACE CONDITIONS AT ALL TIMES. 10. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE CODES. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 11. DO NOT ROUTE ANY PLUMBING PIPING INTO ELEVATOR MACHINE, ELECTRICAL OR TELECOMMUNICATIONS ROOMS EXCEPT FIRE PROTECTION PIPING SERVING THAT ROOM. WHERE UNAVOIDABLE DUE TO ARCHITECTURAL OR STRUCTURAL CONDITIONS, PROVIDE SEPARATION/PROTECTION AS APPROVED BY THE AHJ. 12. PROVIDE WATER HAMMER ARRESTOR (WITH ACCESS PANELS WHERE REQUIRED) TO FLUSH VALVES, SOLENOID VALVE OPERATED PLUMBING FIXTURES & ALL QUICK CLOSING VALVES. INSTALL WATER HAMMER ARRESTORS IN ACCORDANCE WITH PDI-WH2O1, LATEST EDITION. 13. PIPING SHALL BE SUPPORTED AND BRACED PER SMACNA GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS. 14. INSTALL FLEXIBLE CONNECTIONS ON ALL SYSTEMS WHERE REQUIRED AT EXPANSION AND SEISMIC JOINTS. REFER TO SPECIFICATION MATRIX. 15. PIPING TO BE INSTALLED AT 2% GRADIENT WHERE POSSIBLE. REFER TO PLANS FOR PIPING INSTALLED AT DIFFERENT SLOPES. 16. ALL SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN PROJECT DRAWINGS, SPECIFICATIONS, WSEC C403.2.8.1, SECTIONS C403.2.8, C403.2.9 AND TABLE C403.10.3 OF WASHINGTON STATE ENERGY CODE, WHICHEVER IS MOST STRINGENT. 17. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS 18. INSTALL CLEANOUTS WHERE REQUIRED BY 2018 UPC. ALL CLEANOUTS MUST BE PLACED IN ACCESSIBLE LOCATION. 19. PUBLIC USE LAVATORIES AND HAND SINKS SHALL HAVE A SCALD PROTECTION DEVICE THAT MEETS THE ASSE 1070 STANDARD. 20. HEAT TRACE IS REQUIRED WHERE AMBIENT TEMPERATURES FALL BELOW 50 DEGREES ON A REGULAR BASIS. COORDINATE WITH ELECTRICAL CONTRACTOR TO VERIFY CONNECTION POINT. PLUMBING INDEX SHEET NO. SHEET NAME P-001 PLUMBING LEGEND, MAP, B.O.D. & ABBREVIATIONS P-002 SPECIFICATIONS & SCHEDULES P-111 PLUMBING DEMO & NEW WORK PLANS VICINITY MAP -- r Edmonds- Dispensary... 21 Sth St SW 215m St SIN 21 sth St cercres[ health Doyle Sails Seattle SW & Rehab Center Q M Fast Food d'S O Foreit Qv Fast Footl • S / Used a W Seattle Coffe 9 //216th � - Repair f Carter Acura Swedish Medical Cogir of Edmonds oof Lynnwood ' Center Edmonds... Q > Acuradeaier Gin shop Assisted Living and... ® Q Stevens Court Apartments Q 11 Affairs 21eth St sw Swedish Swedish Urgent St SW 11611 S, SW e Clinic © Edmonds Campus Care - EdmoQnds / Q ® Q • INDUSTRIOUS Puget Sound o ®AaahmS ook Jih Palael Cancer Center Steven's Health Center Edmonds Oral & OJeffs Aut epa' Facial Surgery Autorepai hop drew PerryQ Puget Sound Hearing Aid �& Audiology- Edmonds a Hearing aid store eParadise spr so 218th St sw Q Q Ellie Javadi, DDS, MSD, stin Pagan, DDS, MSD Orchid Periodontics... g Premier Thera Dick's Drive -In PY Hamburger • s s Associates me J. Bunnell, PA11 Q WmCo Foods® Q �CESCO Me ical a` Medical supp store Premier Pathology o Custom Dental Care EVgo Charging Station Denali I ociates Med Lab Q Q Q Eye Clinic of Edmonds Cornerstone ®Red Dragon kerb Insurance Groupt%Starbucks r—, ® Casino for tabl Ieledroeic gaming SITE MAP �- IIIIIIIIIIIIIII0. PM K* 0 LEGAL DESCRIPTION PARCEL NUMBER: 00580700002902 LEGAL DESCRIPTION: SECTION 29 TOWNSHIP 27 RANGE 04 QUARTER NW - BLDGS ONLY ON FDP: THE W 331.60FT OF TR 29 EXC TH PTN OF TR 29 LY WLY OF FDL - COM AT NW COR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESCTH SLY TAP 35.44FT FIR SW COR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005); REFER TO 00580700002901 FOR LAND PLUMBING BASIS OF DESIGN ITEM # SYSTEM CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT 1-1 CODE 2018 INTERNATIONAL MECHANICAL CODE CODE COMPLIANCE 1-2 CODE 2018 WASHINGTON STATE ENERGY CODE 1-3 CODE 2018 UNIFORM PLUMBING CODE BASIS FOR PLUMBING DESIGN 2-1 DEMOLITION DEMO EXISTING HAND WASH SINK AND CAP EXISTING UTILITIES (COLD WATER, HOT WATER, SANITARY/VENT) FOR RECONNECTION. DESIGN APPROACH 2-2 NEW WORK EXTEND UTILITIES (COLD WATER, HOT WATER, SANITARY/VENT) THROUGH WALL TO SERVE NEW HANDWASH SINK. DESIGN APPROACH 2-3 SYSTEM CAPACITY NO NEW ADDITIONAL CAPACITY ADDED TO ANY EXISTING DOMESTIC WATER OR SANITARY/VENT SYSTEM. SINK IS LIKE -FOR -LIKE REPLACEMENT. DESIGN APPROACH 2-4 SYSTEM TYPE ALL WATER CONNECTIONS/SANITARY CONNECTIONS ARE TO BE DOMESTIC. NO LAB OR SPECIALTY WASTE OR WATER PROVIDED AS PART OF THIS SCOPE. DESIGN APPROACH try ife Of Your Building WKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: REGISTRATION: L P�� oFof 3999 fG/STfR��G��� SS7DNAL �� 29, 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: PLUMBING LEGEND, ABBREVIATIONS, VICINITY MAP & B.O.D. SHEET NUMBER: PLUMBING SPECIFICATIONS PRESSURE TEST PROCEDURE SEISMIC IMPORTANCE IP INSULATION & JACKETING ID CATEGORY SERVICE DESCRIPTION MANUFACTURER, PRODUCT OR EQUAL MEDIA TEST PRESSURE DURATION CODE DCW, DHW DHWR, TW (POTABLE) DOMESTIC COLD WATER DOMESTIC HOT WATER TO 160OF DOMESTIC HOT WATER RECIRC TO 160OF TEMPERED WATER (60-100°F) PIPE IDENTIFICATION MARKER OPERATING PRESSURE SIZES THRU 2" PIPE MATERIAL JOINTS JOINTS JOINTS COUPLINGS FITTINGS FITTINGS VALVES - ISOLATION VALVES - ISOLATION (ALT) DOMESTIC HOT AND COLD WATER SERVICE COMPLY WITH NSF-61 AND NSF 372 WHITE LETTERING ON GREEN BACKGROUND WATER OR AIR (NOT FOR PLASTIC PIPE) 100% OF OPERATING PRESSURE 15 MINUTES OR MFG SPEC SPC CHAPTER 6 NSF 61 SPC APPENDIX A IAPMO INSTALLATION STANDARDS 1.0 PER S.E.0 SEE INSULATION SCHEDULE NO INSERTS AT HANGERS USE INSERTS AT CLAMPS INSERTS TO BE STYRENE UP TO 100 PSI; SET RELIEF TO 125 PSI COPPER TUBE TYPE L ASTM 688 PER SUBMITTAL PRESS -FIT MECHANICAL COMPRESSION - THREADED AT SPECIALTIES SWEAT: WATER BASED FLUX ASTM B813; LEAD FREE SOLDER ASTM B-321 SILVER BRAZED: PER UPC CHAPTER 6 COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM) COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM) CAST BRONZE -SWEAT- ASTM B584 - LEAD FREE - NSF 61 PRESS FIT LEAD FREE BRONZE BALL VALVE -FULL PORT-1/4 TURN - NSF 61 G & 372 SWEAT - LEAD FREE 2-PC BRONZE BALL VALVE -FULL PORT - 1/4 TURN - NSF 61G & 372 MILWAUKEE UPBA-48013; VIEGA PROPRESS-2971 or 2970; APOLLO 77VLF-100 MILWAUKEE UPBA-48513; APOLLO 77CLF-200 V SANITARY VENT - ABOVE GROUND SANITARY VENT - CAST IRON WHITE LETTERING ON GREEN BACKGROUND UP TO 5 PSI CAST IRON NO -HUB ASTM A 888 & CISPI 301 NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 CAST IRON DRAIN PATTERNS CISPI 301 PER SUBMITTAL PER SUBMITTAL WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION DO NOT USE AIR FOR PLASTIC PIPE TESTING VISUAL INSPECTION WITH NO LEAKS SPC CHAPTER 9 1.0 N/A PIPE IDENTIFICATION MARKER OPERATING PRESSURE ALL SIZES (1) PIPE MATERIAL JOINTS FITTINGS PER SUBMITTAL W SANITARY WASTE - ABOVE GROUND PIPE IDENTIFICATION MARKER SANITARY WASTE - CAST IRON WHITE LETTERING ON GREEN BACKGROUND UP TO 5 PSI CAST IRON NO -HUB ASTM A 888 AND CISPI 301 NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 CAST IRON DRAIN PATTERNS CISPI 301 WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION DO NOT USE AIR FOR PLASTIC PIPE TESTING VISUAL INSPECTION WITH NO LEAKS SPC CHAPTER 7 1.0 N/A OPERATING PRESSURE ALL SIZES (1) PIPE MATERIAL PER SUBMITTAL JOINTS PER SUBMITTAL FITTINGS PER SUBMITTAL ALL CODE ALL DOMESTIC WATER SYSTEM COMPONENTS SHALL MEET NSF STANDARD 61 ALL CODE ALL PLASTIC DRAINAGE SYSTEM COMPONENTS SHALL MEET NSF STANDARD 14 ALL CODE ALL CAST IRON DRAINAGE SYSTEM COMPONENTS SHALL BE TRADEMARKED WITH CAST IRON SOIL PIPE INSTITUTE AND BE LISTED BY NSF. ALL SPECIALTIES PLUMBING SPECIALTIES - APPLICABLE SPECIALTIES IDENTIFIED IN EACH ID CATEGORY IN -LINE VALVE - FACTORY SET - NSF-61 BRASS WITH NEOPRENE VALVE CORES 3/8" INLET CONNECTIONS BALANCING VALVE - THERMOSTATIC CIRCUIT SOLVER UNION ASSEMBLY WITH CHECK VALVE AND ISOLATION VALVES PETE'S PLUG PETERSON EQUIPMENT CO PETE'S PLUG 11 THERMOSTATIC MIXING VALVE - SINGLE POINT OF USE - ASSE 1070 CASH ACME 135, ZURN ZW3870XLT, APOLLO 34C, POWERS HYDROGUARD DEFINITIONS AMERICAN SOCIETY MECHANICAL ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS ELECTRIC RESISTANCE WELD FAHRENHEIT (TEMPERATURE) FEET OF HEAD (PRESSURE) FEMALE PIPE THREAD INCHES MERCURY (PRESSURE) INTERNATIONAL FUEL GAS CODE INTERNATIONAL MECHANICAL CODE MEDICAL NOT APPLICABLE NO -HUB CAST IRON NATIONAL PIPE THREAD POUNDS PER SQUARE INCH (PRESSURE) POLYVINYL CHLORIDE POLYVINYLIDENE FLUORIDE (PLASTIC PIPE) SCHEDULE (PIPE WALL THICKNESS) SCHEDULE STANDARD STANDARD WEIGHT SWEAT (SOLDERED JOINTS) UNDERWRITERS LABORATORY UNIFORM PLUMBING CODE WASHINGTON STATE ENERGY CODE ASME ASTM ERW F FT HD FPT HG IFGC IMC MED N/A NHCI NPT PSI PVC PVDF SCH SCH STD STD WT SWEAT UL UPC WSEC NOTES: 1. MCKINSTRY DOES NOT INSTALL 5" DWV. PLUMBING PIPE INSULATION SCHEDULE - WASHINGTON ENERGY CODE: 2018 INTERNATIONAL ENERGY CODE WITH WASHINGTON AMENDMENTS TABLE C403.10.3 SPECIFICATION: 220716 PLUMBING PIPING INSULATION PIPING TEMP RANGE THERMAL MEAN RATING INSULATION SYSTEM (Deg F) COND. TEMPERATURE MATERIAL <1" 1" TO <1-1/2" 1 1/2" TO 4" 4" - 8" OVER 8" NOTES DOMESTIC COLD WATER 40-60 0.21-0.27 75 MIDI 0.5 0.5 1.0 1.0 1.0 1, 2, 4,10, 11 DOMESTIC HOT WATER 105-140 0.21-0.28 100 MIDI 1.0 1.0 1.5 1.5 1.5 1, 2, 4, 5,10, 11 MPI: MINERAL WOOL PREFORMED PIPE INSULATION E: ELASTORMERIC CLOSED CELL INSULATION PF: POLYURETHANE FOAM CGPI: CELLULAR GLASS PIPE INSULATION CAL-SIL: CALCIUM SILICATE NOTES: 1. FOR PIPING CLAMPED TO UNISTRUT SUPPORTS, UTILIZE RIGID INSERTS WITH SHEETMETAL SHIELDS CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 2. FOR PIPING SUPPORTED FROM CLEVIS HANGERS, IF RIGID INSERTS ARE NOT UTILIZED THE INSULATION SHALL FULLY ENCLOSE THE HANGER AND BE SEALED AT THE TOP AROUND THE SUPPORT ROD; IF RIGID INSERTS ARE UTILIZED THE INSULATION SHALL BE CONTINUOUS THROUGH THE HANGER: INSERT MATERIAL TO BE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 3. DOMESTIC WATER PIPING AND WASTE DRAIN TRAPS EXPOSED TO OUTDOOR CONDITIONS SUCH AS THE GARAGE ENTRY AND FIRST GARAGE LEVEL BELOW GRADE SHALL BE HEAT TRACED AND INSULATED. 4. JACKETING: ALUMINUM ROLLED JACKETING (ARJ) APPLIED TO EXTERIOR PIPING INSULATION EXPOSED TO WEATHER (I.E. ROOFTOP PIPING). PVC JACKETING WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR (PUBLIC AREAS). 5. FOR PIPING SMALLER THAN 1 1/2 INCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. 6. PROVIDE INSULATION ON ALL HORIZONTAL PRIMARY AND OVERFLOW ROOF DRAINAGE BELOW THE ROOF DECK. WHERE THE HORIZONTAL RUN IS LESS THAN 15', PROVIDE INSULATION ON THE RISER DOWN THROUGH THE NEXT FLOOR BELOVI THE ROOF 7. DIRECT BURIED PIPING THAT CONVEYS FLUID AT OR BELOW 60 DEG F IS EXEMPT FROM INSULATION PER WSEC 8. DIRECT BURIED HEATING AND HOT WATER SYSTEM PIPING MAY REDUCE THICKNESS BY 1.5" BUT NOT TO A THICKNESS LESS THAN 1" 9. DOMESTIC HOT WATER WITH ONE WAY DISTRIBUTION TO FIXTURE THAT IS INSTALLED IN -SLAB PEX WITHIN A SMURF TUBE AND AIR BARRIER MEETS WASHINGTON STATE ENERGY CODE PER C404.E 10. FOR PIPING SMALLER THAN 1 1/2 INCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. 11. ASTM E 84 OR UL 723 TESTED TO FLAME SPREAD INDEX OF 25 AND SMOKE DEVELOPED INDEX OF NOT EXCEEDING 50 PLUMBING FIXTURE SCHEDULE TAG MODEL CONNECTION NOTES CW HW TEMP W V RWL ORL HS-1 HAND WASH SINK, WALL MOUNTED, 4" CENTER SET FIXTURE: FAUCET: DRAIN: TRAP: TRAP PRIMER: SAFETY COVER SUPPLIES: MIXING VALVE CARRIER:l ZURN Z5344, VITREOUS CHINA, WALL MOUNT, 20X18, 4" CENTER FAUCET HOLES ZURN Z812B4-XL-17F, 1.5 GPM AERATOR, SENSOR, WRISTBLADE HANDLES, GOOSENECK FAUCET, POLISHED CHROME FINISH ZURN Z8743 GRID STRAINER, BRASS WITH CHROME FINISH ZURN Z8701-PC-BX, 1-1/2" X 1-1/4", 17 GAUGE CHROME PLATED BRASS ZURN Z1021-WL, 1-1/2", 17 GAUGE CHROME PLATED BRASS ZURN Z8946-1-NT, TRAP AND SUPPLY STOP PROTECTORS, SATIN WHITE PVC RESIN 20" CHROME SUPPLIES W/ 1/2" NOM. X 3/8" COMP. ANGLE STOP AND ESCUTCHEON, LOOSE KEY ZURN ZW3870XLT AQUA -GUARD THERMOSTATIC MIXING VALVE, ASSE 1070 COMPLIANT ZURN 1200 SERIES 1/2 1/2 1-1/2 1-1/2 FOR ACCESIBLE USE, MOUNT FIXTURE TO MEET ADA AND LOCAL CODES OR APPROVED ALTERNATE OR APPROVED ALTERNATE USE AS REQUIRED OR APPROVED ALTERNATE OR APPROVED ALTERNATE NOTE: THE ABOVE DATA SHALL BE USED FOR PRELIMINARY ELECTRICAL, STRUCTURAL OR ARCHITECTURAL COORDINATION ONLY. USE APPROVED MANUFACTURER'S SUBMITTAL DATA FOR CONSTRUCTION. SPP = SIZE PER PLANS. ff try ife Of Your Building MCKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: REGISTRATION: P�7�x\' oFof STE 9995 �qNA%- / r '�7. 29 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: SPECIFICATIONS & SCHEDULES SHEET NUMBER: Pm002 1 1 PLUMBING DEMO PLAN P-111 I SCALE: 1/4" = V-0" GENERAL NOTES 1. DEMO & NEW WORK SHOWN BOLD 2 PLUMBING NEW WORK PLAN P-111 SCALE: 1/4" = V-0" KEYNOTES P1 DEMO EXISTING HANDWASH SINK. CAP UTILITIES FOR RECONNECTION. P2 INSTALL NEW HANDWASH SINK. EXTEND UTILITIES (DOMESTIC HOT/COLD WATER, WASTE/VENT) THROUGH WALL TO NEW SINK. P3 PROVIDE NEW SINK WITH NEW ASSE-1070-COMPLIANT THERMOSTATIC MIXING VALVE PER SCHEDULE AND ADA-COMPLIANT PIPE COVERS PER SPECIFICATIONS MATRICES. a try (: ife Of Your Building McKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com PROJECT: SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH ST SW, SUITE 120 EDMONDS, WA 98026 CONSULTANTS: REGISTRATION: I 29 2023 THIS IS AN ELECTRONIC SIGNATURE. DIGITAL STAMP ORIGINAL ON FILE AT MCKINSTRY. ISSUES: DESIGNED: M. CHURCH DRAWN: M. CHURCH CHECKED: D. MA JOB NO: 124016 ISSUED ON: SHEET TITLE: PLUMBING DEMO & NEW WORK PLANS SHEET NUMBER: 1 1 9 1 1 4 1 5 1 6 1 7 1 9 1 9 I 10 1 11 Y x 0 W W si :a GENERAL NOTES ABBREVIATIONS POWER LEGEND AND SYMBOLS POWER LEGEND AND SYMBOLS 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE EDITION AND ALL A AMPERE M/M METER AND MAIN SECTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION APPLICABLE LOCAL CODES AND REGULATIONS. AF AMPERE FRAME RATING (CIRCUIT BREAKER) MV MEDIUM VOLTAGE 2. ALL WORK IS NEW UNLESS NOTED OTHERWISE. AFF ABOVE FINISHED FLOOR NC NORMALLY CLOSED 200 Y CONDUIT WIRING DESCRIPTION PER FEEDER SCHEDULE ON OTHER PLAN A 1 SUBSCRIPT "A-1" REFERS TO PANEL DESIGNATION WITH CIRCUIT NUMBER. TYPICAL OF ALL AFG ABOVE FINISHED GRADE NEC NATIONAL ELECTRICAL CODE RECEPTACLE OUTLETS. 3. ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. AFU AMPERE FUSE RATING (FUSE) NEMA NATIONAL ELECTRICAL MANUFACTURER'S AIC AMPERE INTERRUPTING CAPACITY ASSOCIATION � CONCRETE ELECTRICAL PULL BOX WITH LID APPROPRIATE FOR INSTALLATION LOCATION. LID "ELECTRICAL" "COMM" DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) MOUNTED +15" A.F.F. TO SHALL BE LABELED OR ACCORDING TO USE. BOTTOM OF DEVICE U.O.N. 4. WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO AS AMPERE SWITCH RATING (FUSE) NEW (N) NEW, TO BE FURNISHED AND INSTALLED BY THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. AT AMPERE TRIP RATING (CIRCUIT BREAKER) CONTRACTOR SMOKE FIRE DAMPER DOUBLE DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) MOUNTED +15" 5. WHERE EXISTING CIRCUITS OR DEVICES ARE DEMOLISHED, MODIFIED, OR REUSED, ENSURE ALL EXISTING ELECTRICAL AWG AMERICAN WIRE GAUGE NF NON -FUSED A.F.F. TO BOTTOM OF DEVICE U.O.N. UTILIZATION DEVICES TO REMAIN ARE ENERGIZED UPON COMPLETION OF WORK. BKBD BACKBOARD NIC NOT IN CONTRACT ®p DUCT MOUNTED SMOKE DETECTOR. DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS, GFCI TYPE) MOUNTED +15" 6. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL, PLUMBING AND OTHER EQUIPMENT REQUIRING BLDG BUILDING N/L NIGHT LIGHT THERMOSTAT SUPPLIED BY MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR SHALL STUB 3/4" A.F.F. TO BOTTOM OF DEVICE U.O.N. ELECTRICAL CONNECTION PRIOR TO ANY WORK. BKR BREAKER NO NUMBER, NORMALLY OPEN T O C.O. 6" ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH =0 DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) WITH MOUNTING HEIGHT C CONDUIT NITS NOT TO SCALE EXPOSED STRUCTURE ABOVE OR HARDLID CEILING, PROVIDE 3/4" C.O. BACK TO ASSOCIATED HVAC HORIZONTALLY ABOVE COUNTER TOP PER ARCHITECTURAL PLANS OR APPROVAL. 7. CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC. AND MAKE FINAL CONNECTION AS CB CIRCUIT BREAKER OC ON CENTER UNIT. REFER TO MECHANICAL DETAILS FOR T-STAT MOUNTING HEIGHT REQUIREMENTS. VERIFY DUPLEX RECEPTACLE OUTLET, CONVENIENCE. 20 AMPS, 125 VOLTS, GFCI TYPE WITH ( ) REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. LOCATIONS WITH HVAC CONTRACTOR PRIOR TO ROUGH IN. � MOUNTING HEIGHT HORIZONTALLY ABOVE COUNTER TOP PER ARCHITECTURAL PLANS OR CKT CIRCUIT OD OUTSIDE DIAMETER APPROVAL. 8. LOCATION OF LOCAL WALL SWITCHES ARE SUBJECT TO MODIFICATIONS. AT OR NEAR DOORS, INSTALL SWITCHES ON CFSD COMBINATION FIRE SMOKE DAMPER PB PULL BOX CARBON MONOXIDE SENSOR SUPPLIED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR SIDE OPPOSITE TO DOOR HINGE. VERIFY FINAL HINGE LOCATION IN FIELD PRIOR TO ANY WORK. CO SHALL PROVIDE 3/4" GALVANIZED RIGID CONDUIT WITH PULL STRING BACK TO HEAD END CARBON CA TITLE 24 COMPLIANT DUPLEX RECEPTACLE OUTLET, HALF -CONTROLLED, CONVENIENCE, CO CONDUIT ONLY PF POWER FACTOR MONOXIDE PANEL. REFER TO MECHANICAL DRAWINGS FOR EXACT EQUIPMENT LOCATIONS AND WITH PERMANENT MARKING. 20 AMPS, 125 VOLTS MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE WIRING DETAILS. ( ) 9. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW CT CURRENT TRANSFORMER PNL PANEL U.O.N. DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN CU COPPER POC POINT OF CONNECTION WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL CEILING MOUNTED PLUG LOAD CONTROLLER. CA TITLE 24 COMPLIANT DOUBLE DUPLEX RECEPTACLE OUTLET, HALF -CONTROLLED, TIMES. CL CENTERLINE PP POWER POLE CONVENIENCE, WITH PERMANENT MARKING. (20 AMPS, 125 VOLTS) MOUNTED +15" A.F.F. TO DISC DISCONNECT PWR POWER CONTACT SENSOR FOR HVAC SHUTDOWN. 4S BOX, MOUNTED ABOVE DOOR OR WINDOW, U.O.N. BOTTOM OF DEVICE U.O.N. 10. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL WALL OUTLET BOXES FOR SWITCHES, BELL/STROBES, FIRE DSBN DISTRIBUTION SECTION PVC POLYVINYL CHLORIDE STUB 3/4" C.O. 6" ABOVE CEILING SPACE. PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO SIMPLEX RECEPTACLE OUTLET, CONVENIENCE WITH (2)USB PORTS. (20 AMPS, 125 VOLTS) ALARM PULL STATIONS. RECEPTACLES ETC. WITH CABINETS, FURNITURE, EQUIPMENT ETC., TO AVOID CONFLICT. MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. LEVITON MODEL #T5832. DN DOWN QUAD QUADRUPLEX LOCATION OF ASSOCIATED HVAC THERMOSTAT. 11. WHERE ELECTRIC MOTORS OR HEATERS ARE INSTALLED IN HUNG CEILINGS, PROVIDE DISCONNECT SWITCH IN HUNG DWG DRAWING QTY QUANTITY WP WEATHERPROOF DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) CEILING WITHIN REACH FROM ACCESS POINT. EA EACH RGS RIGID GALVANIZED STEEL MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. 12. FURNISH APPROVED EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. EC ELECTRICAL CONTRACTOR RMC RIGID METALLIC CONDUIT EGC EQUIPMENT GROUNDING CONDUCTOR RM ROOM DUPLEX RECEPTACLE OUTLET, SINGLE SPLIT -CIRCUIT SWITCHED. (20 AMPS, 125 VOLTS) LIGHTING LEGEND AND SYMBOLS 13. FURNISH PULL STRING IN EACH RACEWAY RUN OVER 10' IN LENGTH, IN WHICH PERMANENT WIRING IS NOT INSTALLED. EM EMERGENCY RNC RIGID NONMETALLIC CONDUIT MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. 14. NOT MORE THAN THREE LIGHTING OR CONVENIENCE OUTLET CIRCUITS ARE PERMITTED IN ONE CONDUIT, PROVIDE EMT ELECTRICAL METALLIC TUBING SHT SHEET SURFACE MOUNTED DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) SEPARATE CONDUIT FOR EACH HOMERUN INDICATED ON THE DRAWING, UNLESS INDICATED OTHERWISE. EXIST, (E) EXISTING SIN SOLID NEUTRAL MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. 15. PROVIDE PULL BOXES WHEREVER NECESSARY TO FACILITATE PULLING OF CONDUCTORS. COORDINATE LOCATIONS OF EXO EXTERNAL OPERABLE DISCONNECT SPEC SPECIFICATIONS SYMBOL DESCRIPTION RECESSED CEILING MOUNTED DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) U.O.N. BOXES WITH OTHER TRADES TO AVOID CONFLICT. PULL BOXES SHALL BE ACCESSIBLE. THE SIZE OF PULL BOX SHALL F FUSE sW SWITCH COMPLY WITH N.E.C. REQUIREMENTS. FA FIRE ALARM SWBD SWITCHBOARD FN 2ab/2AB 2'X4' RECESSED LUMINAIRE. FN INDICATES LUMINAIRE TYPE - REFER TO LUMINAIRE SCHEDULE TYPICAL. SUBSCRIPT 2ab REFERS TO CIRCUIT AND SWITCH LEG'a' AND'b', SUBSCRIPT 2AB O ABOVE CEILING, CONCEALED, JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE (NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. 16. OUTLET BOXES FOR FIXTURES RECESSED IN HUNG CEILING SHALL BE ACCESSIBLE THROUGH OPENING CREATED BY FACP FIRE ALARM CONTROL PANEL TC TIME CLOCK N/L REFERS TO CIRCUIT AND ZONE DESIGNATION'A' AND'B'. SUBSCRIPT N/L REFERS TO REMOVAL OF FIXTURES. FF FINISHED FLOOR TEL TELEPHONE UNSWITCHED LEG. TYPICAL OF ALL LIGHTING. RECESSED WALL MOUNTED JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE FG FINISHED GRADE TERM TERMINAL FNE (NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. 17. SEE MECHANICAL AND PLUMBING DRAWINGS AND SPECIFICATION FOR ADDITIONAL CONNECTION REQUIREMENTS TO 7N 2'X4' RECESSED LUMINAIRE WITH 90MIN. EMERGENCY BATTERY BACKUP CONTROL PANELS, CONTROL TRANSFORMERS, POWER FOR CONTROL SYSTEM EP AND PE SWITCHES, TIME CLOCKS, FLA FULL LOAD CURRENT TP TEMPORARY POLE DUPLEX RECEPTACLE, FLUSH IN FLOOR, WATERTIGHT JUNCTION BOX (HINGED BRASS COVER: 20 AMP, 120 VOLT, 2-POLE, 3-WIRE) U.O.N. VALVES, STATS, RELAYS, DUCT SMOKE DETECTOR LOCATIONS, ETC. INDICATED ON CONTROL WIRING DIAGRAMS. GEC GROUNDING ELECTRODE CONDUCTOR TYP TYPICAL I I SURFACE MOUNTED DOUBLE FACE EXIT SIGN (UNIVERSAL ARROWS INDICATED AS NEEDED) ELECTRICAL CONTRACTOR SHALL VERIFY FINAL CONTROL WIRING REQUIREMENTS WITH MECHANICAL AND PLUMBING GEN GENERATOR UGPS UNDERGROUND PULL SECTION SEE NOTE DOUBLE DUPLEX RECEPTACLE, FLUSH IN FLOOR, WATERTIGHT JUNCTION BOX (20 AMP, 120 CONTRACTORS PRIOR TO ANY WORK AND PROVIDE ALL NECESSARY DEVICES AND CONNECTIONS AS REQUIRED. GFCI GROUND FAULT CIRCUIT INTERRUPTER UL UNDERWRITERS LABORATORY ® SURFACE MOUNTED SINGLE FACE EXIT SIGN (UNIVERSAL ARROWS INDICATED AS NEEDED) ® BELOW VOLT, 2-POLE, 3-WIRE) U.O.N. 18. ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE GFP GROUND FAULT PROTECTION UPS UNINTERRUPTIBLE POWER SUPPLY SWITCH, SINGLE POLE 20A. MOUNTED 48" A.F.F. TO TOP OF DEVICE. SUBSCRIPTS INDICATE THE O JUNCTION BOX, FLUSH IN FLOOR, WATERTIGHT (HINGED BRASS COVER: 20 AMP, 120 VOLT, ENVIRONMENT SHALL BE WEATHERPROOF TYPE, NEMA 3R. GND GROUND LION UNLESS OTHERWISE NOTED FOLLOWING: 2-POLE, 3-WIRE) U.O.N. 19. NO CONDUIT RUNS SHALL BE ALLOWED IN CONCRETE SLABS. ALL CONDUITS WILL BE PLACED ABOVE ACCESSIBLE GRC GALVANIZED RIGID CONDUIT V VOLT, VOLTAGE Saab M - MOTOR RATED K - KEY OPERATED FLOOR BOX NOTE CEILING SPACES UNLESS SPECIFICALLY INDICATED TO BE UNDERGROUND. HOA HAND -OFF -AUTOMATIC VA VOLT-AMPERE WHERE INDICATED IN AN EXISTING SLAB, PROVIDE SAWCUTTING OF SLAB AS REQUIRED AND HP HORSE POWER VFC VARIABLE FREQUENCY CONTROLLER 3 - THREE WAY D - DIMMER SWITCH EXTEND CONDUIT AND WIRING TO JUNCTION BOX IN NEAREST ACCESSIBLE WALL. DO NOT 20. LIGHTING, POWER, TELEPHONE AND COMMUNICATIONS OUTLETS SHALL NOT BE PLACED BACK-TO-BACK. 4 - FOUR WAY T - TIMED SWITCHSAWCUT THROUGH POST TENSION SLABS. HV HIGH VOLTAGE VFD VARIABLE FREQUENCY DRIVE 21. WHERE MORE THAN ONE LIGHT SWITCH OCCURS AT SAME LOCATION, SWITCHES SHALL BE MOUNTED IN A MULTIPLE IDF INTERMEDIATE DISTRIBUTION FRAME W WATT a, b, c, ETC. - DESIGNATES SWITCH -LEGS CONTROLLED AND QUANTITY OF SWITCHES AT EACH L5 30R SPECIALTY OUTLET. VERIFY NEMA CONFIGURATION AS NOTED ON PLANS. GANG BOX UNDER A SINGLE COVER PLATE. PLATES WITH MORE THAN (3) LIGHT SWITCHES SHALL BE LABELED TO IG ISOLATED/INSULATED GROUND WH WATT-HOUR LOCATION. INDICATE THE LIGHT FIXTURES CONTROLLED. ISC SHORT CIRCUIT CURRENT AVAILABLE IN RMS WP WEATHERPROOF ® OCCUPANCY SENSOR, DUAL -TECHNOLOGY, SURFACE CEILING MOUNTED. WATT STOPPER BRANCH PANELBOARD, WALL MOUNTED, SEE PLANS AND SCHEDULE. (SURFACE MOUNTED) 22. DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, SYMMETRICAL AMPERES WW WIREWAY MODEL #DT-300 OR LEVITON MODEL #OSC20-MOW. PROVIDE WITH POWER PACK(S) AS REQUIRED. ❑ OR PROVIDED NO MODIFICATION TO EQUIPMENT IS NECESSARY. J-BOX JUNCTION BOX XP EXPLOSION PROOF DUAL TECHNOLOGY OCCUPANCY SENSOR, SURFACE WALL MOUNTED 180° U.O.N. LEVITON BRANCH PANELBOARD, WALL MOUNTED, SEE PLANS AND SCHEDULE. (RECESSED MOUNTED) 23. ALL ELECTRICAL POWER, LIGHTING, TELEPHONE OR SIGNAL WIRING IN FIRE RATED WALL IS TO BE INSTALLED IN A KCMIL THOUSAND CIRCULAR MILS Z IMPEDANCE �..�Q� v MODEL #OSSMT-GD (FOR SINGLE POLE SWITCHING) & LEVITON MODEL #OSSMD-GD FOR (DUAL METALLIC CONDUIT SYSTEM. KW KILOWATT SWITCHING) ® MAIN SWITCHBOARD, POWER OR LIGHT, FLOOR STANDING ENCLOSURE, (SEE SINGLE LINE KV KILO VOLT 4W FOUR -WIRE DIAGRAM AND LOAD SUMMARY) 24. ALL ELECTRIC MATERIAL SHALL BE LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON 3W THREE -WIRE OAR LOW -VOLTAGE OVERRIDE SWITCH. NUMBER INDICATES OVERRIDE SWITCH. A,B,C, ETC. HEAVY DUTY SAFETY SWITCH H.P. AND 600 VOLTS RATED. "F" INDICATES FUSE TYPE. FUSES ALL ELECTRICAL EQUIPMENT. KVA KILO VOLT-AMPERE DESIGNATES AREA AS SHOWN ON LIGHTING SCHEDULE. LDC LOCAL DISTRIBUTION CABINET 5S JUNCTION BOX 0.I100AS PER APPROVED EQUIPMENT MANUFACTURERS SHOP DRAWINGS. SUBSCRIPT INDICATES 25. CONTACT UTILITY COMPANIES FOR SCOPE OF WORK PRIOR TO SUBMITTING BID; INCLUDE UTILITY CHARGES IF ANY. LDF LOCAL DISTRIBUTION FRAME (4 11/16" SQUARED X2 1/8" DEEP) LOW -VOLTAGE DIMMER SWITCH. MOUNTED 48" A.F.F. TO TOP OF DEVICE. 'A, B,C' ETC. - SWITCH AMPERE RATING. # OF POLES TO MATCH SUPPLY CIRCUIT. LCL LONG CONTINUOUS LOAD 0 DIAMETER, PHASE DAB DESIGNATES ZONE CONTROLLED AND QUANTITY OF ZONES AT EACH LOCATION. 0'#2 MAGNETIC MOTOR STARTER H.P. RATED (NUMBER INDICATES NEMA SIZE) 26. ALL DISTRIBUTION AND CONTROL EQUIPMENT (SUCH AS CB's, SWITCHES, CONTACTORS, ETC.), TERMINATIONS SHALL BE FULLY RATED PER UL AS FOLLOWS: LSIG LONG, SHORT, INSTANTANEOUS, GROUND # NUMBER MOUNTING HEIGHT FROM FINISHED FLOOR TO BOTTOM LINE OF OUTLET OR EQUIPMENT. FOR LTG LIGHTING °C DEGREE CELSIUS ® LOW -VOLTAGE OCCUPANCY SENSOR, DUAL -TECHNOLOGY, SURFACE CEILING MOUNTED +96" OR T-6" AFF LIGHT FIXTURES, IT IS TO BOTTOM OF FIXTURE. a. 125A OR LESS: 60°C OR MORE; INTERCONNECTED TO NETWORK LIGHTING CONTROLS. b. MORE THAN 125A : 75°C OR MORE. LV LOW VOLTAGE MFR MANUFACTURER (E) EXISTING DEVICE TO REMAIN DETAIL o. 27. ANY ERRORS, OMISSIONS, OR DESIGN DISCREPANCIES ON PLANS OR SPECIFICATIONS SHALL BE BROUGHT TO THE MAX MAXIMUM (R) REMOVE EXISTING DEVICE AND ASSOCIATED ® CEILING MOUNTED DIGITAL ROOM CONTROLLER INTERCONNECTED TO NETWORK LIGHTING CONTROLS. o. SHEET No. DETAIL REFERENCE ATTENTION OF THE ELECTRICAL ENGINEER FOR CLARIFICATION OR CORRECTION PRIOR TO CONSTRUCTION AND CONDUIT AND WIRE PREPARATION OF SUBMITTAL PACKAGES. MCC MOTOR CONTROL CENTER EQUIPMENT MIN MINIMUM (RL) REMOVE EXISTING DEVICE AND RELOCATE AS EQUIPMENT REFERENCE ID. No. 28. CONDUCTORS SHALL HAVE UNDERWRITER'S LABORATORIES, INC.(UL) LISTED, 600 VOLT INSULATION OF TYPE SPECIFIED MH MANHOLE / METAL HALIDE SHOWN ON PLAN BELOW OR ELSEWHERE IN THE SPECIFICATIONS. CONDUCTORS SHALL BE COPPER AND LISTED FOR 90 DEGREE (NL) NEW LOCATION OF RELOCATED DEVICE SIGNAL LEGEND AND SYMBOLS APPLICATIONS. r , L___J EXISTING (DASH INDICATES) ELECTRICAL EQUIPMENT 1. BRANCH CIRCUITS - LIGHTING AND POWER. GENERAL DEMOLITION NOTES SYMBOL DESCRIPTION ® TELEPHONE BACKBOARD 2'X4'X3/4" PLYWOOD. PROVIDE 2" CONDUIT TO TELEPHONE POC. a. #10 AWG AND SMALLER, SOLID WIRE TYPE THW OR THHN/THWN-2, THHW(THHN FOR DRY LOCATION ONLY). b. #8 AWG TO #2 AWG, STRANDED TYPE THW OR THHN/THHW. DATA OUTLET BOX 4S, MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. STUB 3/4" C.O. 6" c. #1 AWG AND LARGER, STRANDED TYPE XHHW-2. 1. THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND MAKE THEMSELVES COMPLETELY FAMILIAR WITH THE EXISTING ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH - - MOLDED CASE CIRCUIT BREAKER INSTALLED CONDITIONS. A FIELD SURVEY VERIFICATION IS MANDATORY IN ORDER TO SUBMIT AN ELECTRICAL BID, EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO LOCATION OF 2. FEEDERS: TYPE THW OR THHN/THWN-2, OR XHHW-2. FAILURE TO DO SO SHALL NOT RELIEVE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTRACT. NEAREST IDF/MDF. MOLDED CASE SHUNT TRIP CIRCUIT BREAKER 29. PROVIDE GREEN INSULATED GROUNDING CONDUCTOR IN EACH RACEWAY INCLUDING CONDUITS, PLUG STRIPS, 2ALL EQUIPMENT OR WORK REQUIRED TO CARRY OUT THE DEMOLITION SCOPE OF WORK IS CONSIDERED TO BE PART . TELEPHONE OUTLET BOX 4S, MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. STUB 3/4" C.O. - - WIREMOLD. SIZE OF GROUNDING SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE ARTICLE 250. OF THE CONTRACTOR SCOPE OF WORK. NO EXTRAS WILL BE CONSIDERED TO PERFORM THE REQUIRED WORK. 6" ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH 3. THE CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION FROM THE FACILITY DIRECTOR PRIOR TO THE SCHEDULING OF VW EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO LOCATION OF MOLDED CASE DRAW OUT TYPE CIRCUIT BREAKER 30. WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SPACES AND SCHEDULE 40 PVC FOR ANY POWER OUTAGE. SUCH PERMISSION MUST BE OBTAINED IN WRITING AND BE GRANTED AT LEAST 7 DAYS PRIOR TO NEAREST COMMUNICATIONS CABINET OR TELEPHONE BACKBOARD. "W" INDICATES +42" A.F.F. UNDERGROUND INSTALLATION. USE RIGID WHEN ENCASED IN CONCRETE OR SUSCEPTIBLE TO DAMAGE. UNLESS OTHERWISE NOTED. ANY SCHEDULE SHUT DOWN. THE SHUT DOWN SHALL NOT EXCEED A DURATION OF 4 HOURS. 31. ALL SWITCH LOCATIONS ARE REQUIRED TO HAVE A NEUTRAL CONDUCTOR PROVIDED AT THE SWITCH LOCATION PER REMOTE CONTROLLED, ELECTRONICALLY OPERATED CIRCUIT BREAKER NEC 404.2(C). 4. THE CONTRACTOR SHALL NOT STORE ON SITE ANY ITEMS THAT WERE DEMOLISHED FOR ANY EXTENDED PERIOD OF COMBINATION TELEPHONE & DATA OUTLET BOX 4S, MOUNTED +15" A.F.F. TO BOTTOM OF - - TIME, WITHOUT THE WRITTEN PERMISSION OF THE CAMPUS FACILITY DIRECTOR. DEVICE U.O.N. STUB 3/4" C.O. 6" ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF 32. UNLESS OTHERWISE INDICATED, SHARING OF NEUTRAL/GROUNDED CONDUCTORS AMONG SINGLE PHASE BRANCH 0 INSTALLED IN AREA WITH EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" CIRCUITS OF DIFFERENT PHASES INSTALLED IN THE SAME RACEWAY IS NOT PERMITTED. PROVIDE DEDICATED 5. ALL ELECTRICAL ITEMS DESIGNATED AS EXISTING TO REMAIN SHALL AS PART OF THIS SCOPE OF WORK BE CLEANED C.O. BACK TO LOCATION OF NEAREST IDF/MDF, COMMUNICATIONS CABINET, OR TELEPHONE SWITCH AND FUSE ASSEMBLY NEUTRAL/GROUNDED CONDUCTOR FOR EACH INDIVIDUAL BRANCH CIRCUIT. AND TESTED, TO INSURE PROPER OPERATION. ANY ITEMS THAT FAIL TO PASS THE TEST SHALL BE BROUGHT TO THE BACKBOARD. ATTENTION OF THE FIELD INSPECTOR AND THE ENGINEER OF RECORD FOR RESOLUTION. 33. UNLESS OTHERWISE INDICATED, PROVIDE A SEPARATE SWITCHED AND UNSWITCHED PHASE CONDUCTOR TO ALL COMBINATION TELEPHONE & DATA OUTLET BOX 4S, MOUNTED HEIGHT HORIZONTALLY ABOVE CONTROLLED RECEPTACLES REGARDLESS OF RECEPTACLE CONFIGURATION. 6. THE CONTRACTOR SHALL REMOVE ALL EXISTING SWITCHBOARDS, DISTRIBUTION BOARDS, PANEL BOARDS, LIGHTING COUNTER TOP PER ARCHITECTURAL PLANS OR APPROVAL STUB 3/4" C.O. 6" ABOVE CEILING FIXTURES, CONDUITS, WIRES AND OTHER ELECTRICAL APPARATUS DESIGNATED AS EXISTING TO BE REMOVED. SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH EXPOSED STRUCTURE UTILITY COMPANY PULL SECTION LUGS 34. BASIS OF ELECTRICAL DESIGN LIMITS VOLTAGE DROP TO 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. ANY DEMOLITION ITEMS, IF NOT REQUIRED TO BE SALVAGED BY OWNER, BECOME THE PROPERTY OF THE CONTRACTOR ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO LOCATION OF NEAREST IDF/MDF, CHANGES MADE IN THE FIELD SHALL LIMIT VOLTAGE DROP TO THESE PERCENTAGES. AND SHALL BE DISPOSED OF IN AN APPROPRIATE MANNER. COMMUNICATIONS CABINET, OR TELEPHONE BACKBOARD. GROUNDING CONNECTION TO MAIN BUILDING GROUND SYSTEM U.O.N. 35. BRANCH CIRCUIT CONDUITS SHALL BE CONCEALED IN WALL OR CEILING SPACES. EXPOSED CONDUITS ARE NOT 7. THE CONTRACTOR SHALL REMOVE ALL CONDUITS SERVING DEVICES WHICH ARE DESIGNATED AS EXISTING TO BE REMOVED, BACK TO THE SOURCE. O FLUSH FLOOR MOUNTED COMBINATION TELEPHONE &DATA OUTLET BOX, U.O.N. - ALLOWED WHERE CONCEALED METHODS ARE AVAILABLE. N GROUNDING CONNECTION AT SWITCHGEAR/DISTRIBUTION BOARD WITH NEUTRAL BONDING. 36. CONTRACTOR SHALL PROVIDE CONDUCTORS AND CONDUITS REQUIRED FOR ALL BRANCH CIRCUITS AND FEEDERS. FOR 8. DEMOLITION AND/OR REMOVAL OF ELECTRICAL EQUIPMENT IN AREAS TO BE REMODELED SHALL BE THE TELEVISION OUTLET BOX 4S, MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. STUB 3/4" C.O. G CIRCUIT SIZES NOT SHOWN, REFER TO PANEL SCHEDULES FOR CONDUCTOR AND CONDUIT SIZES. RESPONSIBILITY OF THE CONTRACTOR. ,n �LJ 6" ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH _ EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO LOCATION OF 37. ALL EMERGENCY CIRCUITS SHALL BE ENTIRELY INDEPENDENT OF ALL OTHER WIRING AND EQUIPMENT AND SHALL NOT 9• WHERE OUTLETS ARE REMOVED IN EXISTING WALL, REMOVE DEVICES, OUTLETS AND WIRING BACK TO PANELBOARD CABLE TELEVISION TERMINAL OR COMMUNICATIONS CABINET. M IN -LINE UTILITY COMPANY METER ENTER SAME RACEWAY, BOXES OR CABINETS WITH OTHER WIRING EXCEPT WHERE PROVIDED IN NEC 700.96. OR BACK TO NEAREST OUTLET WITH OTHER EXISTING LOAD TO REMAIN. 38. REFER TO LIGHTING CONTROL DETAILS FOR WIRING AND CONDUIT REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL 10. WHERE EXISTING CONDUIT AND CONDUCTORS ARE TO BE REMOVED AND CONDUIT IS INSTALLED IN GROUND OR ELECTRICAL SHEET INDEX ` v UTILITY METER WITH CIRCUIT TRANSFORMERS (CT'S) METER WIRING AND CONDUITS REQUIRED BY MANUFACTURER TO FIXTURES AND CONTROLS. EMBEDDED IN CONCRETE, REMOVE WIRE AND CUT CONDUIT TO BELOW FLOOR, PLUG CONDUIT, PATCH FLOOR AND ABANDON CONDUIT. SOLID STATE DEVICE CONNECTED TO THE POWER DISTRIBUTION SYSTEM SHEET NUMBER SHEET TITLE 39. THE CONTRACTOR SHALL COORDINATE THE WORK WITH OTHER TRADES. ANY COSTS TO INSTALL WORK TO EO.01 ELECTRICAL LEGENDS & NOTES ACCOMPLISH SAID COORDINATION, WHICH DIFFERS FROM THE WORK AS SHOWN ON THE CONTRACT DOCUMENTS, 11. WHERE ELECTRICAL DEVICES ARE TO BE REMOVED, REMOVE ALL CONDUIT AND CONDUCTORS BACK TO SOURCE, GFP GROUND FAULT PROTECTION DEVICE CONNECTED TO THE POWER DISTRIBUTION SYSTEM SHALL BE INCURRED BY THE CONTRACTOR. ANY DISCREPANCIES, AMBIGUITIES OR CONFLICTS SHALL BE BROUGHT TO TERMINAL CABINETS AND RACKS, PROVIDE BLANK COVER PLATE FOR ABANDONED JUNCTION BOXES. sPo SURGE PROTECTION DEVICE THE ATTENTION OF THE OWNER'S REPRESENTATIVE DURING BID TIME FOR CLARIFICATION. ANY SUCH CONFLICTS NOT EO.02 SINGLE LINE DIAGRAM & LOAD SUMMARY CLARIFIED PRIOR TO BID SHALL BE SUBJECT TO THE INTERRUPTION OF THE OWNER'S REPRESENTATIVE AT NO 12. REMOVE ALL CONTROL PANELS, EQUIPMENT RACKS, PULL -BOXES, TERMINAL CABINETS, ETC. FOR SYSTEMS TO BE E0.03 LUMINAIRE SCHEDULE ADDITIONAL COST TO THE OWNER. DEMOLISHED EXCEPT WHERE ANY OF THE EXISTING DEVICES, SYSTEMS, CONSOLES, ETC. ARE TO BE REUSED FOR E1.01 FIRST FLOOR ELECTRICAL FLOOR PLANS UPGRADE. TRANS. °r-x° J300 KVA 40. EXACT ROUTING METHOD AND LOCATION OF CONDUIT PENETRATION AND OPENINGS IN WOOD ROOF DECKS, WALL, 13. PROVIDE BLANK COVER PLATE FOR ALL EMPTY OUTLET BOXES WHERE DEVICES AND/OR CONDUCTORS HAVE BEEN OR PRI:480VA T [ TRANSFORMER WITH SECONDARY GROUND. REFER TO SINGLE LINE DIAGRAM FOR KVA RATING E2.01 ELECTRICAL SPECIFICATIONS FLOORS OR STRUCTURAL STEEL MEMBERS SHALL BE DETERMINED BY THE CONTRACTOR IN FIELD. PERFORM CORING, SEC:208Y/120 AND GROUNDING REQUIREMENTS. E2.02 ELECTRICAL SPECIFICATIONS CONT. SAWCUTTING, PATCHING AND REFINISHING OF EXISTING WALLS AND SURFACES WHEREVER IT IS NECESSARY TO REMOVED AS PART OF THIS CONTRACT. PENETRATE. OPENINGS SHALL BE SEALED IN AN APPROVED METHOD TO MEET THE FIRE RATING AND WATER PROOFING - GND' REQUIREMENTS OF THE PARTICULAR WALL, FLOOR OR CEILING. ALL FIRE SEALS SHALL BE UL APPROVED. CONTRACTOR 14. AFTER REMOVAL OF WIREMOLD AND ASSOCIATED FITTINGS, PATCH, REPAIR AND PAINT AFFECTED SURFACES TO SHALL SCAN ALL CONCRETE WALLS AND SLABS FOR THE PRESENCE OF REBAR AND/OR UTILITIES PRIOR TO DRILLING OR MATCH EXISTING. CUTTING IF CONCRETE WORK IS INVOLVED. CONTRACTOR SHALL PROVIDE CERTIFICATION OF CALIBRATION OF �1 ) ON -SITE GENERATOR SET CONCRETE SCANNING EQUIPMENT PRIOR TO PERFORMING WORK. 15. EXISTING CONDUIT CAN BE REUSED PROVIDING IT IS CODE COMPLIANT, IS CHECKED FOR CONTINUITY OF GROUND, CLEAN AND MANDREL, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 16. REMOVALS AND REPAIRS TO EXISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM CODE REQUIREMENTS. NOTE TO CONTRACTOR DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. tgb1architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PRELIMINARY: NOT F'Ol� CONSTRUCTION gD P WASkj��� r� Z 54830 4 �0GISTEg�'�1�� SIDNAL 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 Project Phase/Status ELECTRICAL LEGENDS & NOTES ISSUANCE No. Description Date CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: BZ DRAWN BY: BZ SHEET NO E0n01 1 2 3 4 5 6 7 8 9 10 11 1 23-196 1 4 6 7 9 10 1 11 GENERAL NOTES 1. REFER TO'GENERAL NOTES' ON ELECTRICAL LEGENDS AND NOTES Y 0 LL w W NON -1 co a EXISTING INCOMIN SNOHOMISH PUD UTILITY SERVICE F__ — __F — _F__ — 2500AAI (E) MAIN SWITCHBOARD 'MDP' 2500A 480Y/277V 30 4W UGPS I � M I � 1 2 3 4 5 6 7 8 9— 2500A I (E) (E) (E) (E) (E) (E) (E) (E) (E) 600A 400A 250A 400A 400A 600A 100A 250A 400A 3P I 3P I 3P I 3P I 3P I 3P I 3P I 3P I 3P I 3P N I� T -I- - 4 -1- - 4 4 •F`STIN�C --+ •F`STIN�C --+ •F`STINO -- •F`STINP--+ •F`STIN�C —4 •F`STI__ -- •F`STI •F`STIN •F`STIN�C --+ EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING I EXISTING EXISTING SERVICE GROUND PANEL PANEL PANEL PANEL PANEL PANEL PANEL IRM4A I 3D4A I I 3X4A I 2D4A I I 1D4A I 11SC4A I I I BD4A (E) ELEVATOR SHUNT TRIP L —_T —r EXISTING EXISTING EXISTING (E) (E) LOAD LOAD LOAD 150A 100A (E) T1 PHA (E) T1 WCA (E) ELEVATOR _ (E) ELEVATOR 45 KVA 112.5 KVA M 1 M 1 �� y PRI:480V �_ F\—&w—] PRI:480V SEC:208Y/120V — SEC:208Y/120V iNA ISTI( � I _ 100A 3P ATS-1 - L N-O\ I G STING / 3P A EXI PANEL XISTIN 1 L4A L T (E) 60,000 KW 480Y/277V 3PH 4W GENERATOR EXISTING L - LOAD EXISTING PANEL 1 WC2A-1 EXISTING LOAD XISTI� EXISTING PANEL CONTRACTOR'S SCOPE — 1WC2A-2 L� SWEDISH WOMEN'S CENTER MOUNTING: SURFACE FED FROM: PANEL'1WCS2A-1' NEMA: 1 AIC RATING: 10,000 w 0 z DESCRIPTION A B C 1 LORAD MACHINE MAMMO 3000 3000 1 LORAD MACHINE MAMMO 3000 ------ 3000 3000 1 LORAD MACHINE RM 131 3000 1 LORAD MACHINE RM 107 3000 ------ 3000 1 LTG- RM US112,113,114,116 500 1 LTG - RM US107,108,118,MM122 500 1 LTG - RM MM116,117,123,125,127 500 1 LTG - RM MM111,128,129 500 1 LTG - RM MM107,130,131 500 1 KODAK MINILOADER 500 500 1 KODAK MINILOADER 500 500 1 MAMMOTEST GENERATOR 4000 4000 SPARE SPARE PANEL ( EXISTING) •O• SUBTOTALS SUBTOTALS 14500 10500 11500 CEC LOAD CALC: CONNECTED DEMAND DEMAND DEMAND LOAD TYPE VA FACTOR VA AMPS (L) LIGHTING 3000 1.25 3750 10 (R) RECEPTACLE 0 NEC 220.44 0 0 (M) MOTOR 0 1.25 0 0 LARGEST MOTOR 0.25 0 0 (C) CONTINUOUS 0 1.25 0 0 (N) NON -CONTINUOUS 50150 1.00 50150 139 (K) KITCHEN (NEC 220.56) 0 0.65 0 0 (S) SPECIAL DEMAND 0 1.00 0 0 TOTALS 53150 53900 TOTAL AMPS CONNECTED AT 208Y1120V 3PH 4W WITH LCL 150 A SINGLE LINE DIAGRAM VOLTAGE: 208YI120V 3PH 4W BUS: 400 A MAIN: MILO FEEDER: EXISTING a A B C DESCRIPTION 1000 RECEIPTS RM MM128, 129, 130 1 1000 RECEIPTS RM MM128, 129, 130 1 1000 ULTRASOUND PWR RM MM129 1 1000 1000 1000 500 500 50 1000 1000 1000 800 500 500 1000 1000 1000 800 500 RECEIPTS RM MM107, 130, 131 IRECEPTS 1 RM MM107, 130, 131 1 RECEIPTS RM MM107, 130, 131 1 RECEIPTS RM MM105, 106, 107 1 RECEIPTS RM MM105, 106, 107 1 RECEIPTS RM MM105, 106, 107 1 RECEIPTS RM MM109, 110-112 1 RECEIPTS RM MM109, 110-112 1 RECEPTS RM MM001 1 LTG - RECEPTION DWNLTS 1 KODAK FILM PROCESSOR 1 KODAK FILM PROCESSOR 1 EXISTING LOAD 1 EXISTING LOAD 1 EXISTING LOAD 1 SHUNT TRIP CONTROL CKT 1 EXISTING LOAD 1 500 EXISTING LOAD 1 5050 5800 5800 SUBTOTALS: PHASE NOTES: 19550 VA A 1. EXISTING BREAKER, EXISTING LOAD 16300 VA B 2. CONTRACTOR SHALL CIRCUIT TRACE AND VERIFY CIRCUIT FEEDING 17300 VA C EXISTING CARDIAC SCANNER IN NUCLEAR IMAGING ROOM AND REUSE 53150 VA TOTAL CIRCUIT FOR NEW CARDIAC SCANNER. 163 AMPS 1 SHEET FOR WIRING METHODS, MATERIALS, AND REQUIREMENTS. tgblarchitects 2. ALL CIRCUIT BREAKERS, PANELBOARDS AND TRANSFORMERS SHALL BE OF THE SAME MANUFACTURER. 3. CONTRACTOR SHALL UPDATE ALL MODIFIED PANEL DIRECTORIES OR CREATE A NEW TYPED DIRECTORY, IF ONE DOES NOT EXIST, IDENTIFYING EACH CIRCUIT AND INSTALLED CIRCUIT LOADS, MOUNTED IN GLASS OR PLASTIC INSIDE DOOR. THE CONTRACTOR SHALL BE t 425.778.1530 RESPONSIBLE FOR UPDATING DIRECTORIES TO INDICATE ALL NEW f 425.774.7803 CIRCUITS AND ACTUAL AREA SERVED WHICH IS NOT NECESSARILY THE DESCRIPTION INDICATED ON THE BID DOCUMENTS. USE A COMPUTER OR TYPEWRITER TO CREATE DIRECTORY; HANDWRITTEN DIRECTORIES ARE NOT ACCEPTABLE. CONSTRUCTION NOTES 21911 76th Ave W. Ste 210 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PRELIMINARY: NOT FOR CONSTRUCTION PpV- gD P. WAShrI��� 54830 IS TEg�'��1s�� SIGNAL 1 10 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 Project Phase/Status SINGLE LINE DIAGRAM & LOAD SUMMARY ISSUANCE No. Description Date CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: BZ DRAWN BY: BZ 1 2 3 4 5 6 7 8 41 PANEL SCHEDULE 2 SHEET NO E0n02 1 23-196 Y -71 0 w 1-1 mom 1 m 1 1 4 4i C 7 8 1 9 1 10 1 11 LUMINAIRE SCHEDULE TYPE VOLTS WATTAGE LUMENS LAMPS MOUNTING FIXTURE DESCRIPTION MFR. CATALOG # NOTES SYMBOL LED RECESSED LED DOWNLIGHT WITH 0-10V FLC6D RF 2000L 120 tgb1architects F1 120 21 W 2,000 3500K RECESSED DIMMING. FOCAL POINT LD1 T LC6 RD 2000L 35K DN CD F2 120 27 W 3,780 LED RECESSED RECESSED 2'X2' LED WITH 0-10V DIMMING. DAY-BRITE 2 FGX G 38L 835 2 FS 3500K UNV DIM t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com LED 28" LED UNDERCABINET FIXTURE WITH 0-10V LINCS100EL28035UNV www.tgbarchitects.com F3 120 7 W 627 3500K SURFACE DIMMING. DAY BRITE SWHDIM LUMINAIRE SCHEDULE NOTES 1. EQUALS SHALL BE CONSIDERED UPON SUBMITTAL REVIEW AND APPROVAL. PLEASE NOTE THAT IF AN ALTERNATE IS CONSIDERED: a. THE CONTRACTOR IS COMPLETELY AND SOLELY RESPONSIBLE FOR ALL ASPECTS OF THE SUBSTITUTION INCLUDING UPDATING CONSTRUCTION DOCUMENTS, OBTAINING APPROVALS AND PERMITS FROM LOCAL AUTHORITY, AND COORDINATING WITH ALL TRADES TO ENSURE CHANGES TO AFFECTED BUILDING SYSTEM ARE ACCOUNTED FOR AND ACCEPTABLE TO THE ENGINEERING TEAM. CONTRACTOR SHALL ENSURE SUBSTITUTED EQUIPMENT MEETS OR EXCEEDS DESIGN INTENT REGARDING RATINGS, PERFORMANCE, DIMENSIONAL CLEARANCES, PHYSICAL DIMENSIONS (MAX/MIN), WEIGHT LIMITATIONS, AND OTHER ASPECTS, PROVING SUBSTITUTION IS SUITABLE TO THE APPLICATION. ENGINEERS WILL REVIEW THE RATING AND PERFORMANCE OF SUBSTITUTED EQUIPMENT ONLY AND WILL NOT ASSUME RESPONSIBILITY FOR SUBSTITUTION AT ANY LEVEL. b. IF CONTRACTOR CANNOT MAKE SUBSTITUTED EQUIPMENT WORK IN THIS PROJECT, CONTRACTOR SHALL REVERT TO REQUIREMENTS OF PERMITTED CONSTRUCTION DOCUMENTS AT THEIR EXPENSE. C. IT IS UNDERSTOOD BY ALL PARTIES THAT ANY SUBSTITUTIONS OF SPECIFIED PRODUCTS ARE DONE FOR THE PURPOSE OF COST SAVINGS TO THE OWNER. THEREFORE, ANY MATERIAL SUBSTITUTION OR DEVIATIONS PROPOSED BY THE CONTRACTOR SHALL BE INCLUDED WITH THE INITIAL BID AND SHALL SHOW A LINE ITEMS CREDIT TO THE OWNER FOR EACH SUBSTITUTION IN LIEU OF SPECIFIED PRODUCTS. d. CONTRACTOR SHALL PROVIDE A POINT BY POINT PHOTOMETRIC STUDY FOR ALL AREAS WHERE ALTERNATE FIXTURES ARE SUBMITTED. LIGHT LEVELS WILL BE REVIEWED FOR COMPLIANCE WITH PROJECT REQUIREMENTS AND BASIS OF DESIGN VALUES. 2. THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE CORRECT CEILING CONFIGURATION AND PROVIDE THE FIXTURES WITH ALL NECESSARY TRIMS AND MOUNTING HARDWARE SO THAT BOTH THE CEILING SYSTEM AND THE FIXTURE CONSTRUCTION MATCHES. PROVIDE SEISMIC HANGERS AS REQUIRED. 3. IT SHALL BE CONTRACTORS RESPONSIBILITY TO VERIFY THE EXACT LOCATION OF ALL LIGHTING FIXTURES AND TYPE OF CEILING WITH ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO ANY WORK. SEE ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO ANY WORK. SEE ARCHITECTURAL ELEVATION DRAWING FOR MOUNTING HEIGHTS OF WALL MOUNTED FIXTURES. 4. A JUNCTION BOX MUST BE PROVIDED WITH ALL EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED OUTLET BOX FOR THROUGH WIRING. 5. A COMPLETE WSEC COMPLIANT LIGHTING CONTROL SYSTEM SHALL BE PROVIDED TO CONTROL ALL INTERIOR AND EXTERIOR LIGHTING SYSTEMS. REFER TO LIGHTING CONTROL DIAGRAMS, SCHEDULES AND DETAILS. 6. BATTERY PACK EMERGENCY TEST SWITCHES SHALL BE INTEGRAL TO LIGHT FIXTURE. COORDINATION OF SWITCH LOCATION IS REQUIRED WITH DESIGN TEAM IF INTEGRAL INSTALLATION IS NOT POSSIBLE. 7. FIXTURES DESIGNATED AS EMERGENCY SHALL BE SUPPLIED WITH INTEGRAL BATTERY PACK CAPABLE OF POWERING TWO T8 LAMPS FOR 90 MINUTES WITH A TOTAL LIGHT OUTPUT OF 1100 LUMENS OR ONE F13 BIAX FOR 90 MINUTES WITH A TOTAL LIGHT OUTPUT OF 520 LUMENS. 8. PROVIDE ALL REQUIRED MOUNTING HARDWARE ANCHORAGE AND SUPPORTS TO INSTALL LIGHTING FIXTURES. 9. PROVIDE SWIVEL BASE AND STEMS. LENGTHS AS REQUIRED TO MOUNT THE PENDANT MOUNTED FIXTURES. THE INSTALLATION SHALL COMPLY WITH TITLE 24 SEISMIC AND APPLICABLE UBC REQUIREMENTS. 10. THE CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERABLE LIGHTING SYSTEM AS PART OF THIS BUILDING CONTRACT. 11. FOR SUSPENDED AND SURFACE MOUNTED LIGHT FIXTURES, THE PRODUCT OF ICP NEED NOT EXCEED 12 FOR ANY VALUE OF 1. 12. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT THE FIXTURE BALLAST OR DRIVER VOLTAGE MATCHES THE CIRCUIT VOLTAGE SUPPLYING FIXTURE PRIOR TO ORDERING. 13. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY BALLAST/DRIVER DIMMING CONFIGURATION IS COMPATIBLE WITH CONTROLS BEING PROVIDED PRIOR TO ORDERING FIXTURES. EX. 2 WIRE, 3 WIRE, 4 WIRE, 0-10V, CAT 5, ETC. 14. LED LIGHT FIXTURES SHALL BE IN ACCORDANCE WITH IES, NFPA, UL, AS SHOWN ON THE DRAWINGS, AND AS SPECIFIED. 15. LED LIGHT FIXTURES SHALL BE REDUCTION OF HAZARDOUS SUBSTANCES (ROHS)-COMPLIANT. 16. LED DRIVERS SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED: • MINIMUM EFFICIENCY: 85% AT FULL LOAD. • MINIMUM OPERATING AMBIENT TEMPERATURE: -20 DEG C. (4 DEG F.) • INPUT VOLTAGE: 120 - 277V (±10%) AT 60 HZ., UNLESS OTHERWISE INDICATED. • INTEGRAL SHORT CIRCUIT, OPEN CIRCUIT, AND OVERLOAD PROTECTION. • POWER FACTOR: >=0.95. • TOTAL HARMONIC DISTORTION: <=20%. • COMPLY WITH FCC 47 CFR PART 15. 22. LED MODULES SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED: • COMPLY WITH IES LM-79 AND LM-80 REQUIREMENTS. • MINIMUM CRI 80 AND COLOR TEMPERATURE 4000K UNLESS OTHERWISE SPECIFIED IN LUMINAIRE SCHEDULE. • MINIMUM RATED LIFE: 50,000 HOURS PER IES L70. • LIGHT OUTPUT LUMENS AS INDICATED IN THE LUMINAIRE SCHEDULE. 23. LED DOWNLIGHTS: • HOUSING, LED DRIVER, AND LED MODULE SHALL BE PRODUCTS OF THE SAME MANUFACTURER. 24. LED TROFFERS: • LED DRIVERS, MODULES, AND REFLECTOR SHALL BE ACCESSIBLE, SERVICEABLE, AND REPLACEABLE FROM BELOW THE CEILING. • HOUSING, LED DRIVER, AND LED MODULE SHALL BE PRODUCTS OF THE SAME MANUFACTURER. 25. ALL FIXTURES MOUNTED OUTDOORS SHALL BE LISTED FOR WET LOCATION. 26. ALL REMOTE DRIVERS SHALL BE CONCEALED ABOVE CEILING OR PLACED IN A REMOTE LOCATION WHEN ATTIC SPACE IS NOT AVAILABLE. PRELIMINARY: NOT FOR CONSTRUCTION gD P WASk 54830 4 �0SGISTEg�'�1�� SIONAL 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 Project Phase/Status LUMINAIRE SCHEDULE ISSUANCE No. Description Date CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: BZ DRAWN BY: BZ 1 2 3 4 5 Er 1 8 1 9 1 10 1 11 SHEET NO E0n03 23-196 1 4 C 7 10 1 11 GENERAL NOTES 1. COORDINATE POWER AND DATA DEVICE LOCATIONS, AND DEVICE PLATE COLOR WITH ARCHITECT. Y W EW m a CONSTRUCTION NOTES: O DENOTES FIXTURE SUPPORT WIRE (MINIMUM #10) FROM LUMINARIE ATTACHED TO BUILDING STRUCTURE. ABOVE. O DENOTES RECESSED LED DOWNLIGHT. O DENOTES T-BAR CEILING SYSTEM BY OTHERS. NOTE: PROVIDE FIXTURE SUPPORT WIRES AT ALL 4 CORNERS OF FIXTURES IF FIXTURE DOES NOT REST ON TWO MAIN RUNNERS AT OPPOSITE ENDS OF FIXTURE. #12 AWG STEEL SLACK SUPPORT WIRE TO STRUCTURAL MEMBER 2 WIRES REQUIRED/FIXTURE SCREW CLIP TO LIGHT FIXTURE (TYPICAL 2 EACH END) CEILING TILE CEILING GRID DOWN LIGHT FIXTURE IN T-BAR CEILING DETAIL 1. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF CEILING GRID AND TILE SYSTEM. 3 NUCLE POWER & SIGNAL PLAN - LEVEL 1 - NEW NORTH 4F NORTH ^'dw SCALE: 114" =1' - 0" EYPLAN ARE„ 1 2. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN A SPACE EXTENDING FROM FLOOR TO A HEIGHT OF U ABOVE THE EQUIPMENT. NEC 110.26(E)1. 3. COORDINATE LIGHT FIXTURE LOCATIONS AND LIGHT SWITCH LOCATIONS, COLOR, AND STYLE WITH ARCHITECT. 4. REFER TO LIGHTING CONTROL DETAILS FOR WIRING AND CONDUIT REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL WIRING AND CONDUITS REQUIRE BY MANUFACTURER TO FIXTURES AND CONTROLS. CONSTRUCTION NOTES ONEW LIGHT SWITCH SHALL REPLACE EXISTING. CONTRACTOR SHALL REUSE EXISTING CIRCUIT IN SPACE. ONEW LIGHT FIXTURE SHALL REPLACE EXISTING. CONTRACTOR SHALL REUSE EXISTING CIRCUIT IN SPACE TO PROVIDE POWER TO NEW FIXTURE. EXISTING DECORATIVE LENS TO BE REINSTALLED. ONEW LIGHT FIXTURE SHALL REPLACE EXISTING. CONTRACTOR SHALL REUSE EXISTING CIRCUIT IN SPACE TO PROVIDE POWER TO NEW FIXTURE. OCONTRACTOR SHALL CIRCUIT TRACE TO VERIFY EXISTING 20 AMP CIRCUIT FEEDING THE EXISTING D-SPECT CARDIAC SCANNER POWER AND REUSE FOR NEW. O NEW 1440 VA UPS FOR NEW CARDIAC SCANNER BACKUP BATTERY POWER SUPPLY. NEW UPS SHALL REPLACE EXISTING AND SHALL BE PROVIDED BY THE EQUIPMENT VENDOR, COORDINATE WITH OWNER. O CONTRACTOR SHALL PROVIDE POWER TO NEW FIXTURE FROM EXISTING LIGHT CIRCUIT IN HOT LAB ROOM. tgb1architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PRELIMINARY: NOT FOR CONSTRUCTION gD P. WASk y 54830 4' �0GISTE1�,�� YONAL 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 Project Phase/Status FIRST FLOOR ELECTRICAL FLOOR PLANS ISSUANCE No. Description Date CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: BZ DRAWN BY: BZ 1 2 3 LIGHTING FIXTURE SUSPENSION DETAIL 4 5 7 LIGHTING PLAN - LEVEL 1 - NEW 8 SCALE: 114" = 1' - 0" I 2 9 10 11 SHEET NO El n0l 23-196 1 1 9 1 3 1 1n 1 11 Y -71 x 0 LL W W zi -m :a ELECTRICAL SPECIFICATIONS PART 1 GENERAL 2. CEILING SENSOR SWITCH SHALL BE WATT STOPPER DUAL -TECHNOLOGY MODE. 7. NEUTRAL BUSES: 100 PERCENT OF THE AMPACITY OF PHASE BUSES, UNLESS OTHERWISE INDICATED, EQUIPPED WITH PRESSURE CONNECTORS 1.01 SCOPE OF WORK 3. PROVIDE 120/277V CEILING SENSOR POWER PACK INSTALLED IN J-BOX NEXT TO LIGHTING CIRCUIT. FOR OUTGOING CIRCUIT NEUTRAL CABLES. BUS EXTENSIONS FOR BUSWAY FEEDER NEUTRAL BUS ARE BRACED. A. WORK COVERED BY THIS SECTION CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT, SUPPLIES, AND MATERIALS, UNLESS OTHERWISE SPECIFIED, 2.08 RECEPTACLES AND IN PERFORMING ALL OPERATIONS NECESSARY FOR THE INSTALLATION OF A COMPLETE AND OPERABLE ELECTRICAL SYSTEM AS REQUIRED BY P. FUTURE DEVICES: EQUIP COMPARTMENTS WITH MOUNTING BRACKETS, SUPPORTS, BUS CONNECTIONS, AND APPURTENANCES AT FULL RATING OF THESE SPECIFICATIONS AND AS INDICATED ON THE DRAWINGS. A. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE, 20 AMPS, 125 VOLTS, 3-WIRE, SIDE -WIRED WITH BINDING SCREWS, PARALLEL SLOTS, CIRCUIT -BREAKER COMPARTMENT. U-GROUND, PLASTER EARS AND CAPTIVE MOUNTING SCREWS. BODY SHALL BE PHENOLIC, PLASTIC, OR BAKELITE. RECEPTACLES SHALL BE B. THE CONTRACTOR SHALL EXAMINE ALL DRAWINGS AND SPECIFICATIONS IN A MANNER TO BE FULLY COGNIZANT OF ALL WORK REQUIRED UNDER HEAVY-DUTY, 3-BLADE CURRENT CARRYING CONTACT AND DOUBLEWIDE FLAT BLADE GROUND CONTACTS. PROVIDE ARROW HART 5242-1 HUBBELL Q. EQUIP DISTRIBUTION SECTIONS WITH FULL HEIGHT VERTICAL BUSSING TO ACCOMMODATE MAXIMUM UTILIZATION OF SPACE FOR DEVICES. THIS SECTION. 5242-1 OR LEVITON 5242-1. INSTALL GROUND PIN DOWN. C. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS UNLESS OTHERWISE ARRANGED AND SCHEDULE ALL REQUIRED B. SINGLE RECEPTACLES SHALL BE SPECIFICATION GRADE, GROUNDING TYPE, SIDE -WIRED, WITH BINDING SCREWS, AND SHALL HAVE STANDARD SIZE 2.15 ELECTRICAL CONNECTIONS INSPECTIONS FOR THE EXECUTION OF THE WORK UNDER THIS CONTRACT. IVORY BAKELITE BASE. FOR CIRCUITS CONSISTING OF ONE SINGLE RECEPTACLE ONLY, AMPERE RATING OF RECEPTACLE SHALL BE THE SAME AS CIRCUIT BREAKER OF FUSE. FOR RECEPTACLES RATED 15 AMPS/125 VOLTS, PROVIDE NEMA 5-15R, ARROW -HART 5251-1. FOR RECEPTACLES RATED 1.02 GENERAL REQUIREMENTS 20 AMPS / 125 VOLTS, PROVIDE NEMA 5-20R, ARROW -HART 5721-1, OR EQUAL. INSTALL GROUND PIN DOWN. A. UNLESS OTHERWISE NOTED, ALL WIRING FOR MOTORS, STARTERS, CONTROLS, AND EQUIPMENT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. WHERE MOTORS FOR MECHANICAL EQUIPMENT ARE FURNISHED BY OTHER DIVISIONS, WIRING SHALL BE THE RESPONSIBILITY OF A. WORK DONE UNDER THIS SECTION SHALL COMPLY WITH THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE, NEC (NATIONAL ELECTRICAL 2.09 DEVICE PLATES THE ELECTRICAL CONTRACTOR, EXCEPT WHERE WIRED INTEGRALLY WITH THE EQUIPMENT. CODE), WASHINGTON STATE ENERGY CODE (WSEC), AND TO ANY APPLICABLE LOCAL JURISDICTIONAL REQUIREMENTS. IN CASE OF CONFLICT BETWEEN REQUIREMENT, THE MOST RESTRICTIVE SHALL APPLY. 1. PROVIDE PLATES FOR ALL SWITCHES, RECEPTACLES, JUNCTION BOXES, TELEPHONE AND OTHER OUTLETS. B. CONNECTION AND CONTROL DIAGRAMS FOR ALL MECHANICAL AND CONTROL EQUIPMENT SHALL BE FURNISHED UNDER OTHER DIVISIONS, AND BE APPROVED BY THE OWNER FOR CONNECTION BY THE ELECTRICAL CONTRACTOR. 1.03 ELECTRICAL CONTRACTOR'S RESPONSIBILITY 2. PROVIDE ENGRAVED OR ETCHED PLATES FOR ALL LOCK SWITCHES, PILOT SWITCHES, SWITCHES FROM WHICH EQUIPMENT OR CIRCUIT CONTROLLED CANNOT BE READILY SEEN, THREE OR MORE SWITCHES UNDER A COMMON PLATE AND FOR SWITCHES AS INDICATED. 2.16 SUPPORTING DEVICES A. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN A COMPLETE SET OF DRAWINGS AND SPECIFICATIONS. CONTRACTOR SHALL CHECK THE DRAWINGS OF THE OTHER TRADES AND SHALL CAREFULLY READ THE ENTIRE SPECIFICATIONS AND DETERMINE HIS RESPONSIBILITIES. 3. STAINLESS STEEL PLATES SHALL BE AMERICAN IRON AND STEEL INSTITUTE (AISI) TYPE 302, WITH BEVELED EDGES, 0.040" THICK WITH SATIN SMOOTH FINISH. "SMOOTHIE," HUBBELL #97071 SERIES. A. ALL EQUIPMENT CONDUITS SHALL BE SUPPORTED, ANCHORED AND BRACED IN ACCORDANCE WITH THE MOST STRINGENT CODES AND B. BEFORE SUBMITTING THE BID, THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH EXISTING REQUIREMENTS. COMPLY WITH CHAPTER 23 OF THE LATEST CBC (CALIFORNIA BUILDING CODE). CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE EQUIPMENT AND ASSOCIATED WIRING IN SUCH A MANNER AS TO 4. PLASTIC COVER PLATE SHALL BE HIGH IMPACT THERMOPLASTIC, HIGH STRENGTH, SCRATCH -RESISTANT, SMOOTH AND SELF -EXTINGUISHING, CONFORM WITH THE EXISTING STRUCTURE OF THE BUILDING, AVOID OBSTRUCTIONS, AND MEET APPLICABLE CODE REQUIREMENTS. HUBBELL "PI" SERIES OR PASS & SEYMOUR RP SERIES. PART 3 EXECUTION C. THE INTENT OF THESE DRAWINGS IS TO DESCRIBE A COMPLETE AND OPERABLE SYSTEM. WHERE EXISTING CONDITIONS DIFFER FROM DRAWINGS, 5. WHERE OUTLETS ARE INDICATED TO BE WEATHERPROOF, PROVIDE AN AISI TYPE 302 STAINLESS WITH DOUBLE HINGED COVERS, PASS & SEYMOUR 3.01 WORKMANSHIP AND COMPLETION OF INSTALLATION ADJUSTMENT SHALL BE MADE AND ALLOWANCES INCLUDED FOR ALL NECESSARY EQUIPMENT TO COMPLETE ALL PARTS OF THE DRAWINGS AND #WPD-8. SPECIFICATIONS. BRING ANY QUESTIONS TO THE ARCHITECT OR ENGINEER'S ATTENTION PRIOR TO BIDDING. A. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE ELECTRICAL AND MECHANICAL EFFICIENCY. DEFECTIVE AND DAMAGED 6. GALVANIZED STEEL PLATES SHALL BE SQUARE OR RECTANGULAR AND HOT DIPPED GALVANIZED OR SHERARDIZED, BEVELED EDGES AND 0.040" SHALL MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL INTERPRETATIONS INCLUDED. ANY DEFICIENCY PERTAINING TO EITHER D. WHEREVER A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT, DEVICES, CIRCUIT BREAKERS, ETC., ARISES ON THE DRAWING THICK. GALVANIZED STEEL PLATES SHALL BE USED IN UTILITY AREA. WORKMANSHIP MATERIALS FOUND BY THE INSPECTOR SHALL BE CORRECTED WITHOUT ADDITIONAL COST TO THE OWNER. AND/OR SPECIFICATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITION NOTED ON DRAWINGS AND/OR IN SPECIFICATIONS TO ENSURE COMPLETE AND OPERABLE SYSTEMS AS REQUIRED BY 7. PROVIDE PLATES EQUIPPED WITH CLOSE FITTING OPENINGS FOR THE EXACT DEVICE TO BE USED. PROVIDE PLATES FOR TELEPHONE OUTLETS THE OWNER AND ENGINEER. EQUIPPED WITH BUSHED OPENINGS. B. THE CONTRACTOR SHALL MAINTAIN ON JOB SITE A SET OF THE WORKING DRAWINGS WHICH SHALL BE UPDATED DAILY IN DETAIL FOR WORK ACCOMPLISHED. UPON COMPLETION OF THE WORK, A SET OF REPRODUCIBLE CONTRACT DRAWINGS SHALL BE OBTAINED FROM THE GENERAL 1.04 WORK NOT INCLUDED 8. REFER TO SECTION 3.08 FOR LABELING OF PLATES. CONTRACTOR AND ALL CHANGES AS NOTED ON THE RECORD SET OF PRINTS SHALL BE INCORPORATED THEREON WITH RED INK IN A NEAT, LEGIBLE, UNDERSTANDABLE AND PROFESSIONAL MANNER. A. CERTAIN LABOR, MATERIALS, OR EQUIPMENT MAY BE FURNISHED UNDER OTHER CONTRACTS BY THE OWNER. WHEN SUCH IS THE CASE, THE 9. COVER PLATES ON PRESSED STEEL OUTLET BOXES IN FURRED AREAS, ATTICS, ETC., OR EXPOSED IN MECHANICAL EQUIPMENT ROOMS SHALL BE OF EXTENT, SOURCE, AND DESCRIPTION OF THESE ITEMS WILL BE INDICATED ON THE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS. UNLESS THE SAME MATERIAL AS THE OUTLET BOX. C. ALL EQUIPMENT AND MATERIAL CONNECTED WITH THIS PROJECT SHALL BE INSTALLED COMPLETE, THOROUGHLY CLEANED, AND ALL RESIDUE OTHERWISE NOTED, ALL LABOR, MATERIALS AND EQUIPMENT FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL WORK SHALL BE PROVIDED REMOVED FROM INSIDE SURFACES. EXTERIOR SURFACES OF ALL MATERIAL AND EQUIPMENT SHALL BE CLEANED AND DELIVERED IN A PERFECT, UNDER THIS SECTION OF THESE SPECIFICATIONS. 10. COVER PLATES IN LOCATIONS CONCEALED FROM PUBLIC VIEW SHALL HAVE THE CIRCUIT NUMBERS AND SOURCE FEED POINT HAND LABELED UNBLEMISHED CONDITION. WITH MARKING BLACK PEN (PERMANENT MARKER). SEE SECTION 3.08 FOR LABELING. 1.05 SPECIAL REQUIREMENTS D. UPON COMPLETION OF THE INSTALLATION AND AS A CONDITION OF ITS ACCEPTANCE FURNISH ONE COPY OF THE FINAL INSPECTION CERTIFICATE 11. PROVIDE PLASTIC COVER PLATES UNLESS NOTED OTHERWISE TO THE OWNER. A. THE DRAWINGS INDICATE GENERAL ARRANGEMENT OF CIRCUITS, OUTLETS, LOCATIONS OF MOTOR CONTROLLERS WITH DISCONNECTS, PANELBOARDS, CONDUIT ROUTING, AND OTHER WORK. INFORMATION SHOWN ON THE DRAWINGS IS ESSENTIALLY DIAGRAMMATIC; HOWEVER, 2.11 INTERIOR LIGHTING FIXTURES RECIRCUITING OR RELOCATING ELECTRICAL EQUIPMENT WILL NOT BE PERMITTED WITHOUT SPECIFIC WRITTEN APPROVAL OF THE ENGINEER. 3.02 PREPARATION COORDINATION. A. FURNISH, INSTALL AND WIRE LIGHTING FIXTURES SCHEDULED OR INDICATED BY TYPE DESIGNATION ON THE DRAWINGS. IF TYPE DESIGNATION IS 1.06 SUBMITTALS OMITTED, FIXTURES SHALL BE OF THE SAME TYPE AS SHOWN FOR ROOMS OF SIMILAR USAGE. VERIFY BEFORE PURCHASE AND INSTALLATION. NO A. THE CONTRACTOR SHALL COORDINATE THIS WORK WITH ALL OTHER CONTRACTORS FURNISHING LABOR, MATERIALS AND WORK, SO THAT THE ALTERNATIVE FIXTURES WILL BE ACCEPTED. WORK AS WHOLE SHALL BE EXECUTED AND COMPLETED WITHOUT CONFLICT OR DELAY. A. AFTER AWARD OF THE CONTRACT AND BEFORE ANY MATERIALS ARE DELIVERED TO THE JOB SITE, A COMPLETE LIST OF ALL MATERIALS PROPOSED TO BE FURNISHED AND INSTALLED UNDER THIS SECTION MUST BE PROVIDED. B. LOCATIONS OF FIXTURES ON ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. VERIFY LOCATION AND SPACING WITH ARCHITECTURAL REFLECTED B. EXAMINE THE DRAWINGS AND SPECIFICATIONS AND DETERMINE THE WORK TO BE PERFORMED BY THE ELECTRICAL, MECHANICAL AND OTHER CEILING PLANS AND OTHER REFERENCE DATA BEFORE PURCHASING. COORDINATE SPACE CONDITIONS, INCLUDING HEADROOM CLEARANCES AND TRADES. PROVIDE THE TYPE AND AMOUNT OF ELECTRICAL MATERIALS AND EQUIPMENT NECESSARY TO PLACE THIS WORK IN PROPER OPERATION, B. SUBMIT TO THE ENGINEER FOR APPROVAL ONE PRINT AND ONE REPRODUCIBLE OF ALL LIGHTING FIXTURES, SWITCHGEAR, PANELBOARDS, MOTOR INTERFERENCES WITH CEILING COMPONENTS SUCH AS DUCTS, OPENINGS, BEAMS AND PIPING PRIOR TO INSTALLATION. COMPLETELY WIRED TESTED AND READY FOR USE. THIS SHALL INCLUDE ALL CONDUIT, WIRE, DISCONNECTS, RELAYS, AND OTHER DEVICES FOR CONTROL CENTERS, TRANSFORMERS, AND MOTOR STARTERS. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S PRINTED INFORMATION FOR THE REQUIRED OPERATION SEQUENCE OF ALL ELECTRICAL, MECHANICAL, AND OTHER SYSTEMS OR EQUIPMENT. EACH OF THESE ITEMS IDENTIFIED ON THE DRAWINGS. THE INFORMATION SHALL INCLUDE, AS MINIMUM, OVERALL DIMENSIONS, WEIGHT, PHASE, C. CHECK THE ARCHITECTURAL FINISHES AND, REGARDLESS OF THE CATALOG PREFIXES AND SUFFIXES SHOWN, FURNISH FIXTURES WITH THE VOLTAGE RATINGS, WIRING DIAGRAMS, AND NAMEPLATE DATA. PROPER TRIM, FRAMES, SUPPORTS, HANGERS AND OTHER MISCELLANEOUS APPURTENANCES OR PROPERLY COORDINATE WITH SAID FINISHES. C. PERFORM ALL WORK IN A MANNER WHICH WILL NOT CAUSE UNNECESSARY INCONVENIENCE OR DANGER TO THE OCCUPANTS, NOR INTERFERE WHERE REQUIRED, FURNISH REINFORCING FOR CEILING CONSTRUCTION TO SUPPORT THE WEIGHT OF THE FIXTURES. WITH THE ACTIVITIES IN THE BUILDING. 1.07 STANDARDS AND MATERIALS D. FIXTURES SHALL BE FREE OF LIGHT LEAKS AND DESIGNED TO PROVIDE SUFFICIENT VENTILATION OF LAMPS AND BALLASTS, INCLUDING VENT HOLES A. ALL MATERIALS SHALL CONFORM WITH THE CURRENT APPLICABLE INDUSTRY STANDARDS, NEMA (NATIONAL ELECTRICAL MANUFACTURER'S WHERE REQUIRED. OUTDOOR FIXTURES WITH VENT HOLES SHALL HAVE WIRE MESH SCREENS IN THE VENT HOLES. D. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE EACH POWER INTERRUPTION WITH OWNER, AND SHALL PROVIDE AT LEAST TWO WEEKS ASSOCIATION), ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE), IPCEA (INSULATED POWER CABLE ENGINEERS ASSOCIATION), IEEE (INSTITUTE NOTICE OF PROPOSED INTERRUPTION AND WORK TO BE ACCOMPLISHED. OF ELECTRICAL AND ELECTRONIC ENGINEERS), NATIONAL ELECTRICAL SAFETY CODE. E. REPLACE BLEMISHED, DAMAGED OR UNSATISFACTORY FIXTURES AT NO ADDITIONAL COST TO THE OWNER AND IN A MANNER SATISFACTORY TO THE ARCHITECT. B. UNLESS OTHERWISE INDICATED, ALL MATERIALS SHALL BE UNDERWRITERS LABORATORIES LISTED AND LABELED, OR CERTIFIED BY A NATIONALLY 3.04 CORE CUTTING, DRILLING, AND PATCHING RECOGNIZED TESTING LABORATORY. F. LAMPS C. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE ELECTRICAL MECHANICAL EFFICIENCY. DEFECTIVE AND DAMAGED 1. LAMPS SHALL BE NEW AND OF WATTAGE AND TYPE INDICATED OR AS REQUIRED FOR THE PARTICULAR FIXTURE INSTALLED. A. NO HOLES WILL BE ALLOWED IN ANY STRUCTURAL MEMBERS WITHOUT THE WRITTEN APPROVAL OF THE ARCHITECT OR STRUCTURAL ENGINEER MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL APPROVAL AND ACCEPTANCE. THE DRAWINGS AND SPECIFICATIONS TAKE AND GENERAL CONTRACTOR. PRECEDENCE WHEN THEY ARE MORE STRINGENT THAN CODES, STATUTES, OR ORDINANCES IN EFFECT. APPLICABLE CODES, STANDARDS, 2. UNLESS OTHERWISE NOTED, LAMPS DESCRIBED IN FIXTURE SCHEDULE, ANSI NOMENCLATURE, MANUFACTURED BY GENERAL ELECTRIC, SYLVANIA, ORDINANCES, AND STATUTES TAKE PRECEDENCE WHEN THEY ARE MORE STRINGENT OR CONFLICT WITH THE DRAWINGS OR SPECIFICATIONS. PHILLIPS, OR EQUAL. 3.05 INSTALLATION 1.08 DELIVERY AND STORAGE OF MATERIALS 3. PROVIDE INCANDESCENT LAMPS AND TUNGSTEN -HALOGEN LAMPS AS 130 VOLT RATED WHENEVER SUCH DESIGNS ARE AVAILABLE. A. WORKMANSHIP IS TO BE NEAT, BY EXPERIENCED WORKMEN WITH ADEQUATE SUPERVISION, AND IN LINE WITH NORMAL INDUSTRY WORK PRACTICES. A. THE CONTRACTOR SHALL INVESTIGATE EACH SPACE IN THE BUILDING THROUGH WHICH EQUIPMENT MUST PASS TO REACH ITS FINAL LOCATIONS. IF 4. PROVIDE FLUORESCENT LAMPS AS INDICATED ON THE DRAWINGS. ALL LINEAR FLUORESCENT LAMPS ARE TO BE INSTALLED WITH THE LABEL FACING NECESSARY, THE MANUFACTURER SHALL BE REQUIRED TO SHIP HIS MATERIAL IN SECTIONS, SIZED TO PERMIT PASSING THROUGH SUCH THE SAME DIRECTION. B. MAINTAIN WORKING CLEARANCE AROUND ELECTRICAL EQUIPMENT, IN ACCORDANCE WITH CODE REQUIREMENTS AS A MINIMUM. RESTRICTED AREAS IN THE BUILDING. 5. PROVIDE HIGH INTENSITY DISCHARGE (H.I.D.) LAMPS OF TYPE AND WATTAGE AS SHOWN ON THE DRAWINGS. LAMPS SHALL BE COMPATIBLE WITH B. THE CONTRACTOR SHALL RETAIN IN HIS POSSESSION AND SHALL BE RESPONSIBLE FOR ALL PORTABLE AND DETACHABLE PARTS OF PORTIONS OF FIXTURE BALLAST. MANUFACTURERS: G.E. CO., PHILLIPS, SYLVANIA, OR EQUAL. C. WHERE LIGHTING FIXTURES AND OTHER ELECTRICAL ITEMS ARE SHOWN IN CONFLICT WITH LOCATIONS OF STRUCTURAL MEMBERS AND INSTALLATIONS SUCH AS FUSES, KEY LOCKS, ADAPTERS, BLOCKING CLIPS, AND INSERTS UNTIL FINAL COMPLETION OF WORK. THESE PARTS SHALL MECHANICAL OR OTHER EQUIPMENT, FURNISH AND INSTALL ALL REQUIRED SUPPORTS AND WIRING TO CLEAR THE ENCROACHMENT. BE DELIVERED TO THE OWNER UPON COMPLETION OF THE WORK. 1. EXIT SIGNS LIGHTS SHALL BE LED TYPE AND PROVIDED WITH AN INTEGRAL EMERGENCY BATTERY PACK. D. VERIFY LOCATION OF EACH OUTLET FOR POWER, SIGNAL, TELEPHONE/DATA, AND EACH LIGHTING FIXTURE WITH ARCHITECT PRIOR TO ROUGH -IN. PART 2 PRODUCTS J. LED LIGHT FIXTURES INCLUDE IN BID COST OF RELOCATING EACH ITEM WITHIN TEN -FEET RADIUS OF ITS INDICATED LOCATION. 2.01 EQUIPMENT AND MATERIALS A. GENERAL: E. ALL CONDUIT TO BE RUN CONCEALED UNLESS OTHERWISE NOTED. ALL CONDUITS SHALL BE ROUTED OVERHEAD IN CEILING SPACES. NO CONDUITS SHALL BE PERMITTED IN CONCRETE SLAB, MASONRY WALLS UNLESS SPECIFICALLY SO INDICATED. CONDUIT SHALL BE RUN SO AS NOT TOINTERFERE A. ALL MATERIALS FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW, FREE FROM DEFECTS, AND SHALL BE GUARANTEED FORA 1. LED LIGHT FIXTURES SHALL BE IN ACCORDANCE WITH IES, NFPA, UL, AS SHOWN ON THE DRAWINGS, AND AS SPECIFIED. WITH OTHER PIPING FIXTURES OR EQUIPMENT. PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF THE WORK. SHOULD ANY TROUBLE DEVELOP DURING THEIR PERIOD DUE TO DEFECTIVE 2. LED LIGHT FIXTURES SHALL BE REDUCTION OF HAZARDOUS SUBSTANCES (ROHS)-COMPLIANT. MATERIALS OR FAULTY WORKMANSHIP, THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIALS AND LABOR TO CORRECT THE TROUBLE 3. LED DRIVERS SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED: WITHOUT ANY COST TO THE OWNER. ANY DEFECTIVE MATERIAL OR INFERIOR WORKMANSHIP NOTED AT THE TIME OF INSTALLATION SHALL BE a. MINIMUM EFFICIENCY: 85% AT FULL LOAD. F. WHERE ALLOWED, EXPOSED CONDUIT RUNS SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO WALLS, STRUCTURAL MEMBERS, OR CORRECTED IMMEDIATELY TO THE SATISFACTION OF THE OWNER. b. MINIMUM OPERATING AMBIENT TEMPERATURE: -20 DEG C. (4 DEG F.) INTERSECTION OF VERTICAL PLANES AND CEILINGS. B. ALL MAJOR EQUIPMENT COMPONENTS SHALL HAVE THE MANUFACTURER'S NAME, ADDRESS, MODEL NUMBER, AND SERIAL NUMBER PERMANENTLY c. INPUT VOLTAGE: 120 - 277V (±10%) AT 60 HZ. G. ALL ELECTRICAL CONDUITS AND OTHER ELECTRICAL RACEWAYS PASSING THROUGH FIRE RATED CEILINGS, SLABS, CABLE TRAYS, WALLS AND ATTACHED IN A CONSPICUOUS MANNER. PARTITIONS SHALL BE SEALED TO PREVENT THE SPREAD OF FIRE, SMOKE, AND GASSES. USE A UL LISTED AND APPROVED FIRE -STOP MATERIAL d. INTEGRAL SHORT CIRCUIT, OPEN CIRCUIT, AND OVERLOAD PROTECTION. EQUAL TO RATING OF A WALL OR A FLOOR SLAB PENETRATED; INSTALLATION OF FIRE -STOP MATERIAL SHALL BE IN ACCORDANCE WITH 2.02 CONDUIT MANUFACTURERS INSTRUCTIONS. e. POWER FACTOR: >=0.95. A. PROVIDE RACEWAYS AS INDICATED ON THE DRAWINGS AND AS HEREIN SPECIFIED. CONDUITS SHALL BE RIGID STEEL "GRC" (THICK WALL) H. UNLESS WRITTEN PERMISSION IS GRANTED BY THE ARCHITECT, NO MATERIAL SHALL BE MOUNTED ON THE EXTERIOR WALLS OR PARAPET TOP OF GALVANIZED; ELECTRICAL METALLIC TUBING "EMT" (THIN WALL); FLEXIBLE STEEL, GALVANIZED; LIQUID -TIGHT, FLEXIBLE STEEL CONDUIT WITH f. TOTAL HARMONIC DISTORTION: <=20%. THE BUILDING. GROUND BOND; ALUMINUM CONDUIT; OR SCHEDULE 40 PVC. B. ALL EMPTY CONDUITS (CO) SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE INDICATED ON THE DRAWING. g. COMPLY WITH FCC 47 CFR PART 15. 1. ALL ROTATING ELECTRICAL EQUIPMENT SHALL BE SUPPLIED WITH A FLEXIBLE, LIQUID -TIGHT CONDUIT WITH APPROPRIATE SLACK AND SHALL NOT EXCEED THIRTY-SIX (36) INCHES. C. WHERE CONDUIT CROSSES AN EXPANSION JOINT, PROVIDE APPROVED FITTINGS WHICH ALLOW DEFLECTIONS EQUIVALENT TO TWICE THE 4. LED MODULES SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED: MOVEMENT ALLOWED BY THE DESIGN. J. ALL POWER WIRING SHALL BE INSTALLED IN CONDUIT. a. COMPLY WITH IES LM-79 AND LM-80 REQUIREMENTS. 2.03 CONDUCTORS K. TELEPHONE WIRES SHALL BE PLENUM RATED CABLE FOR MOUNTING IN CEILING SPACES WITHOUT CONDUIT UNLESS OTHERWISE NOTED. b. MINIMUM CRI 80 AND COLOR TEMPERATURE 4000K UNLESS OTHERWISE SPECIFIED IN LUMINAIRE SCHEDULE. A. PROVIDE A COMPLETE SYSTEM OF CONDUCTORS IN RACEWAY SYSTEMS AS SHOWN ON THE DRAWINGS AND THEN HEREIN SPECIFIED. L. ALL WIRES FOR ALL SYSTEMS SHALL BE CONTINUOUS FROM SWITCH TO TERMINAL OR FURTHEST OUTLET. NO JOINTS SHALL BE MADE EXCEPT IN B. LIGHTING AND POWER CONDUCTORS SHALL BE COPPER, 600 VOLT, TYPE THWN/THHN, NO. 12 MINIMUM UNLESS OTHERWISE NOTED. c. MINIMUM RATED LIFE: 50,000 HOURS PER IES L70. PULL, JUNCTION OR OUTLET BOXES, OR IN PANEL OR SWITCHBOARD GUTTERS. C. CONTROL CONDUCTORS SHALL BE 600V, TYPE THWN/THHN, NO.14 MINIMUM SIZE UNLESS OTHERWISE NOTED. d. LIGHT OUTPUT LUMENS AS INDICATED IN THE LUMINAIRE SCHEDULE. M. ALL RECEPTACLE, CONTROL DEVICE, AND SWITCH MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH -IN. 2.04 FITTINGS B. LED DOWNLIGHTS: 3.06 GROUNDING A. CONNECTOR, COUPLING, LOCKNUT, BUSHINGS AND CAPS USED WITH RIGID CONDUIT SHALL BE STEEL, THREADED AND GALVANIZED. BUSHINGS SHALL BE INSULATED. 1. HOUSING, LED DRIVER, AND LED MODULE SHALL BE PRODUCTS OF THE SAME MANUFACTURER. A. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AS INDICATED ON DRAWINGS AND AS REQUIRED BY THE LATEST EDITION OF APPLICABLE CODES. B. EMT FITTINGS, CONNECTORS AND COUPLINGS SHALL BE STEEL, ZINC, OR CADMIUM PLATED, COMPRESSION TYPE, WITH INSULATED THROAT. C. LED TROFFERS: B. FURNISH AND INSTALL ALL GROUNDING CONDUCTORS, CONDUIT AND CLAMPS. THE SIZE OF THE GROUNDING CONDUCTORS SHALL BE NOT LESS C. FLEXIBLE STEEL CONDUIT CONNECTORS SHALL BE TWIST -IN -TYPE WITH INSULATED THROAT. THE FINISH SHALL BE ZINC OR CADMIUM PLATING. 1. LED DRIVERS, MODULES, AND REFLECTOR SHALL BE ACCESSIBLE, SERVICEABLE, AND REPLACEABLE FROM BELOW THE CEILING. THAN THAT SPECIFIED IN THE NEC. D. EMT CONDUIT FITTINGS SHALL BE THE COMPRESSION TYPE; SET SCREW FITTINGS SHALL NOT BE USED. 2. HOUSING, LED DRIVER, AND LED MODULE SHALL BE PRODUCTS OF THE SAME MANUFACTURER. C. BUILDING GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 25 OHMS. 2.05 JUNCTION AND PULL BOXES 2.12 LOW VOLTAGE SWITCHGEAR D. EACH BRANCH CIRCUIT SHALL BE EQUIPPED WITH CODE SIZE GREEN GROUND, EQUIPMENT WIRE (PER NEC 250-95) (NOT INDICATED ON DRAWINGS) WITHIN THE SAME CONDUIT FOR ALL CIRCUITS OF PANELBOARDS. A. FOR INTERIOR DRY LOCATIONS, BOXES SHALL BE GALVANIZED ONE-PIECE DRAWN STEEL, KNOCKOUT TYPE WITH REMOVABLE, MACHINE SCREW A. FURNISH AND INSTALL ALL SWITCHBOARDS AS HEREINAFTER SPECIFIED AND AS SHOWN ON THE DRAWINGS. SWITCHBOARDS SHALL BE OF THE SECURED COVERS. DEAD FRONT SAFETY TYPE EQUIPPED WITH THE THERMAL MAGNETIC 40°C CIRCUIT BREAKERS. 3.07 BRANCH CIRCUITS B. ALL BOXES SHALL BE SIZED FOR THE NUMBER AND SIZES OF CONDUCTORS AND CONDUITS ENTERING THE BOX AND EQUIPPED WITH PLASTER B. CIRCUIT BREAKERS SHALL BE RATED MINIMUM 10,000 AMPS RMS SYMMETRICAL INTERRUPTING CAPACITY AND SHALL BE THE NUMBER OF POLES RINGS WHERE REQUIRED. AND CURRENT CAPACITY AS INDICATED ON THE SINGLE LINE DIAGRAM. SWITCHBOARDS SHALL BE SQUARE-D, GE, OR EATON/CUTLER HAMMER. A. NO MORE THAN THREE BRANCH CIRCUITS PERMITTED IN ONE CONDUIT UNLESS INDICATED OTHERWISE 2.06 OUTLET BOXES C. LABEL EACH SWITCHBOARD COMPARTMENT WITH ENGRAVED METAL OR LAMINATED -PLASTIC NAMEPLATE WITH WHITE LETTERS ON BLACK A. FOR FIXTURES, BOXES SHALL BE GALVANIZED, ONE-PIECE DRAWN STEEL, KNOCKOUT TYPE EQUIPPED WITH 3/8" FIXTURE STUDS AND PLASTER BACKGROUND, MOUNTED WITH CORROSION -RESISTANT SCREWS. 3.09 PROTECTION RINGS WHERE REQUIRED. D. ENCLOSURE FINISH FOR OUTDOOR UNITS: NEMA 3R WEATHERPROOF ENCLOSURE WITH FACTORY -APPLIED FINISH IN MANUFACTURER'S STANDARD A. USE ALL MEANS NECESSARY TO PROTECT THE WORK AND MATERIALS FROM LOSS DURING AND AFTER INSTALLATION, AND PROVIDE ADEQUATE B. FOR CONVENIENCE OUTLETS, WALL SWITCHES, OR OTHER DEVICES, OUTLET BOXES SHALL BE GALVANIZED ONE-PIECE DRAWN STEEL, KNOCKOUT COLOR, UNDERSURFACES TREATED WITH CORROSION -RESISTANT UNDERCOATING. AND PROPER STORAGE FACILITIES DURING THE PROGRESS OF THE WORK. PROVIDE FOR THE SAFETY AND GOOD CONDITION OF ALL WORK UNTIL TYPE 4"X4"X1-1/2" MINIMUM. FINAL ACCEPTANCE OF THE WORK BY THE OWNER. REPLACE ALL DAMAGE OR DEFECTIVE WORK, MATERIAL, AND EQUIPMENT AT NO EXPENSE TO THE OWNER BEFORE REQUESTING FINAL ACCEPTANCE. E. ENCLOSURE FINISH FOR INDOOR UNITS: FACTORY -APPLIED FINISH IN MANUFACTURER'S STANDARD GRAY FINISH OVER A RUST -INHIBITING PRIMER C. FOR LOCATIONS WHERE STANDARD BOXES ARE NOT SUITABLE, SPECIAL BOXES SHALL BE DESIGNED TO FIT SPACE OR MEET OTHER REQUIREMENTS ON TREATED METAL SURFACE. AND SUBMITTED FOR APPROVAL. 3.10 CLEANING OF EQUIPMENT, MATERIAL, AND PREMISES 2.07 SWITCHES F. BARRIERS: BETWEEN ADJACENT SWITCHBOARD SECTIONS. A. SITE SHALL BE LEFT BROOM CLEAN AFTER COMPLETION OF WORK EACH DAY. UPON COMPLETION OF THE WORK, LEAVE THE PREMISES CLEAN OF ALL DIRT AND DEBRIS. A. ALL DEVICES SHALL CONFORM TO NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) STANDARDS AND SHALL BE UNDERWRITERS' G. UTILITY METERING COMPARTMENT: FABRICATED COMPARTMENT AND SECTION COMPLYING WITH UTILITY COMPANY'S REQUIREMENTS. IF LABORATORIES, INC., (UL) LISTED AND LABELED AND SHALL BE "SPECIFICATION GRADE," MEETING THE REQUIREMENTS OF FEDERAL SPECIFICATION SEPARATE VERTICAL SECTION IS REQUIRED FOR UTILITY METERING, MATCH AND ALIGN WITH BASIC SWITCHBOARD. B. ALL EQUIPMENT AND MATERIAL CONNECTED WITH THIS PROJECT SHALL BE INSTALLED COMPLETE, THOROUGHLY CLEANED, AND ALL RESIDUE WS-896-E, FOR SWITCHES. REMOVED FROM INSIDE SURFACES. EXTERIOR SURFACES OF ALL MATERIAL AND EQUIPMENT SHALL BE CLEANED AND DELIVERED IN A PERFECT, H. BUS TRANSITION AND INCOMING PULL SECTIONS: MATCHED AND ALIGNED WITH BASIC SWITCHBOARD. UNBLEMISHED CONDITION. 1. WALL SWITCHES SHALL BE SPECIFICATION COMMERCIAL GRADE (MINIMUM), FULLY ENCLOSED, QUIET -TYPE TUMBLER SWITCHES RATED 20 AMPERES, 120/277-VOLT, BAKELITE OR COMPOSITION, BACK AND SIDE WIRED, BUMPER PAD, FULL RATING FOR INDUCTIVE OR NON -INDUCTIVE LOADS I. BUSES AND CONNECTIONS: THREE PHASE, FOUR WIRE, UNLESS OTHERWISE INDICATED. 3.11 HANDLING OF WIRE AND CABLE AND INCANDESCENT OR FLUORESCENT LIGHTING LOADS. 2. SINGLE POLE SWITCHES: G.E. 59511, HUBBELL #1221, ARROW #1991 OR PASS & SEYMOUR 20AC1. 1. PHASE- AND NEUTRAL -BUS MATERIAL: HARD -DRAWN COPPER OF 98 PERCENT CONDUCTIVITY WITH FEEDER CIRCUIT -BREAKER LINE CONNECTIONS. A. HANDLE WIRE AND CABLE SO AS TO AVOID DAMAGE TO CONDUCTORS AND TAKE EVERY PRECAUTION TO AVOID SHARP BENDING OR SCORING OF IF BUS IS COPPER, USE COPPER FOR FEEDER CIRCUIT -BREAKER LINE CONNECTIONS. THE CABLE. CABLE SHALL NOT BE LAID NOR DRAGGED UPON THE GROUND. 3. THREE-WAY QUIET SWITCHES: G.E. 59531, HUBBELL #1223, ARROW #1993 OR PASS& SEYMOUR 20AC3. 2. LOAD TERMINALS: INSULATED, RIGIDLY BRACED, SILVER-PLATED, COPPER RUNBACK BUS EXTENSIONS EQUIPPED WITH PRESSURE CONNECTORS B. THE CONTRACTOR SHALL BE REQUIRED TO REMOVE AND REPLACE AT HIS OWN EXPENSE ALL WIRE AND CABLE DAMAGED DUE TO IMPROPER 4. WALL SWITCH AND PILOT LIGHTS SHALL BE FLUSH MOUNTED COMBINATION WALL TYPE WITH SWITCH AND PILOT LIGHT EQUIPPED WITH A 6-WATT, FOR OUTGOING CIRCUIT CONDUCTORS. PROVIDE LOAD TERMINALS FOR FUTURE CIRCUIT -BREAKER POSITIONS AT FULL AMPERE RATING OF HANDLING, AND SHALL PAY FOR THE NEW WIRE OR CABLE. 125-VOLT CANDELABRA BASE LAMP. THE PILOT LIGHT SHALL HAVE A GREEN JEWEL WITH BRASS RIM FLUSH MOUNTED IN THE WALL PLATE. CIRCUIT -BREAKER POSITION. 5. ALL SWITCHES SHALL BE OF THE SAME MANUFACTURE. 3. GROUND BUS: 1/4-BY-2-INCH- (6-BY-50-MM-) MINIMUM -SIZE, HARD -DRAWN COPPER OF 98 PERCENT CONDUCTIVITY, EQUIPPED WITH PRESSURE 3.12 TESTING AND INSPECTIONS CONNECTORS FOR FEEDER AND BRANCH -CIRCUIT GROUND CONDUCTORS. FOR BUSWAY FEEDERS, EXTEND INSULATED EQUIPMENT GROUNDING 6. NORMAL SWITCH COLOR IS WHITE APPROVED BY ARCHITECT/OWNER. SWITCHES CONTROLLING CIRCUITS CONNECTED TO EMERGENCY POWER CABLE TO BUSWAY GROUND CONNECTION AND SUPPORT CABLE AT INTERVALS IN VERTICAL RUN. A. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS FOR THE EXECUTION OF THE SOURCE SHALL BE RED. WORK UNDER THIS CONTRACT. 4. CONTACT SURFACES OF BUSES: SILVER PLATED. 7. 30 AMP MOTOR RATED SNAP SWITCHES SHALL BE LEVITON MS302-DS. PROVIDED IN NEMA 1 OR 3R ENCLOSURE AS SHOWN ON DRAWING. B. SENSOR SWITCH (MOTION SENSOR) 5. MAIN PHASE BUSES, NEUTRAL BUSES, AND EQUIPMENT GROUND BUSES: UNIFORM CAPACITY FOR ENTIRE LENGTH OF SWITCHBOARD'S MAIN AND DISTRIBUTION SECTIONS. PROVIDE FOR FUTURE EXTENSIONS FROM BOTH ENDS. 1. WALL SENSOR SWITCH SHALL BE WATT STOPPER DUAL TECHNOLOGY OCCUPANCY SENSOR LEVITON MODEL #OSSMT-GD (FOR SINGLE POLE SWITCHING) & LEVITON MODEL #OSSMD-GD FOR (DUAL SWITCHING). 6. ISOLATION BARRIER ACCESS PROVISIONS: PERMIT CHECKING OF BUS -BOLT TIGHTNESS. tgb1architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PRELIMINARY: NOT FOR CONSTRUCTION gD P. WASk 54830 4' �0GIST� SIDNAL 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS SWEDISH EDMONDS NUC MED EQUIPMENT REPLACEMENT 7320 216TH STREET SW SUITE 120 EDMONDS, WA 98026 Project Phase/Status ELECTRICAL SPECIFICATIONS ISSUANCE No. Description Date CD SET 06/30/23 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: BZ DRAWN BY: BZ SHEET NO E2n0l 1 2 3 4 5 6 7 8 9 10 11 1 23-196 IMAGING ROOM ENVIRONMENTAL REQUIREMENTS (REQUIRED 24 / 7) 1. AMBIENT OPERATION TEMPERATURE: 59-75-F 2. PERMITTED TEMPERATURE VARIATION: t 5.4° F PER HOUR 3. HUMIDITY: 30-65%(NON-CONDENSING) 4. PERMITTED HUMIDITY VARIATION: 35%PER HOUR FLOOR LEVELNESS REQUIREMENTS tDHE.REE.7.VER M ACCEPTABLE FLOOR LEVELNESS DEVIATION IS 0.30 3.311 SHIELDING REQUIREMENTS IN RELATION TO DISTANCE OF UNWANTED SOURCE' DISTANCE OF UNWANTED EXTERNAL RADIATION SOURCE FROM D-SPECTTM DETECTOR HEADS TYPE OF SHIELDING 2M 4M 6M (6.56 FT) (13.12 FT) (19.68 FT) WITHOUT SHIELDING OT APFR—D NOT APPROVED OK LEAD SHIELDING: 0.5 MM (0.019 IN) NOT OK OK qP PROVEo LEAD SHIELDING: 1 MM (0.039 IN) OK OK OK LEAD SHIELDING: 3 MM (0.118 IN) OK OK OK 'SUITABLE FOR ISOTOPES WITH AN ENERGY RANGE OF UP TO 170 KEV, WITH MAXIMAL ACTIVITY OF 30 mCi. CUSTOMER'S APPROVAL SIGNATURE PRINT NAME DATE Drawn by: DEREKLARSEN Client: SPECTRUM DYNAMICS Project: PROVIDENCE SWEDISH EDMONDS Drawing Title: SHEET TITLE: ARCHITECTUAL LAYOUT SYSTEM TYPE: DSPECT CARDIO Date: 06/13/2023 Scale: 1:30 Revisian:C Sheet: Al S P E GYFZU DYNAMICS MEDICAL EQUIPMENT LISTING (ITEMS PROVIDED BY CUSTOMERICONTRACTOR) TAG `J DESCRIPTION 110V, 15A, NEMA 5-15, 4 FLEX LAN CONNECTION 4 DIRECT CAT6 CONNECTION (NON NETWORKED) 110V, 20A, NEMA 5-20R, MAINS, DEDICATED CIRCUIT 24 GROUNDING BAR / AWG #4 GROUNDING WIRE (SEE ELECTRICAL NOTE #7) 25 V x 2" WIRE MOLDING / CABLE CHASE HATCH LEGEND 2" FLOOR -MOUNT/ WALL -MOUNT WIRE RACEWAY PN DESCRIPTION QTY. 2300BACD LOW PROFILE, TWO-PIECE RACEWAY W/DIVIDER 20 818 90° EXTERNAL ELBOW N/A 811 90° FLAT ELBOW 1 815 TEE 1 817 90° INTERNAL ELBOW 2 806 COVER CLIP 6 1. UPS: 11OV, 20A, DEDICATED CIRCUIT NOTE: UPS SUPPLIES POWER TO THE FOLLOWING EQUIPMENT: a.DSPECT SCANNER b.GATE DEVICE (POWER FROM UPS) 2. SECONDARY UPS NOTE: SECONDARY UPS SUPPLIES POWER TO THE FOLLOWING EQUIPMENT: a. ACQUISITION COMPUTER b. ACQUISITION COMPUTER MONITOR c. PROCESSING COMPUTER c. PROCESSING COMPUTER MONITOR 3. RFID STATION W/PERIPHERALS (EXTERNALLY POWERED) 4. PRINTER (IF APPLICABLE): (EXTERNALLY POWERED) CUSTOMER'S APPROVAL SIGNATURE PRINT NAME DATE Drawn by: Project: Date: DEREK LARSEN PROVIDENCE SWEDISH EDMONDS 06/13/2023 Scale: Client: Drawing Title: 1/2"=1' SPECTRUM DYNAMICS SHEET TITLE: ELECTRICAL LAYOUT R e v i s i a n: C SYSTEM TYPE: DSPECT CARDIO Sheet: E1 ELECTRICAL NOTES 1. ALL WIRES SPECIFIED SHALL BE STRANDED, FLEXIBLE, THERMO-PLASTIC, COLOR CODED, COPPER ONLY, CUT 10 FOOT LONG AT OUTLET BOXES, DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS, UNLESS OTHERWISE SPECIFIED. ALL CONDUCTORS, POWER, SIGNAL AND GROUND MUST BE RUN IN CONDUIT OR DUCT SYSTEM. ELECTRICAL CONTRACTOR SHALL RING OUT AND TAG ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BE CONTINUOUS COPPER AND FREE FROM SPLICES. 2. IT IS RECOMMENDED THAT ALL WIRES BE COLOR CODED AS REQUIRED IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES. 4. CONDUIT SIZES SHALL BE VERIFIED BY THE ARCHITECT, ELECTRICAL ENGINEER OR CONTRACTOR IN ACCORDANCE WITH LOCAL OR NATIONAL CODES. 5. CONVENIENCE OUTLETS ARE ILLUSTRATED. USE HOSPITAL APPROVED OUTLET OR EQUIVALENT. 6. ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., OTHER THAN SHOWN ON THIS DRAWING MAY RESULT IN THE NEED FOR GREATER THAN STANDARD CABLE LENGTHS 7. THE CUSTOMER IS REQUIRED TO INSTALL ONE OF THE FOLLOWING TO ESTABLISH CONNECTION TO MAINS GROUND/BUILDING STEEL: • GROUNDING BAR (MCMASTER PART # 7137K71, CATALOG PAGE-798, OR EQUIVALENT) • GROUNDING WIRE AWG#4 (MCMASTER PART # 7512K75, CATALOG PAGE-798, OR EQUIVALENT) ONE SIDE OF THE GROUNDING WIRE MUST BE CONNECTED TO THE GROUNDING BAR USING A COMPRESSION LUG (MCMASTER PART# 6926K51, CATALOG PAGE 717, OR EQUIVALENT). THE OTHER SIDE SHOULD BE CONNECTED TO CONSTRUCTIONAL STEEL. IN CASES WHERE CONNECTION IS MADE TO THE BUILDING GROUNDING STEEL ROD - USE DUAL -NUT CLAMPS (MCMASTER PART # 7491 K91 OR 7491 K92, CATALOG PAGE-798, OR EQUIVALENT). NOTE: THE PART NUMBERS ABOVE ARE USED AS AN EXAMPLE; THESE PARTS ARE AVAILABLE FROM MCMASTER (AT WWW.MCMASTER.00ML THE CUSTOMER MAY USE MATERIALS FROM ANY OTHER SUPPLY COMPANY. HOWEVER, PARTS MUST BE SIMILAR TO THOSE RECOMMENDED ABOVE AND MUST MEET LOCAL ELECTRICAL REQUIREMENTS, 8. THE MAXIMUM POINT TO POINT DISTANCES ILLUSTRATED ON THIS DRAWING MUST NOT BE EXCEEDED. S P E GYFZU DYNAMICS MEDICAL DSPECT SCANNER FLOOR LOADS NET WEIGHT 1,477 LBS GANTRY FLOOR LOAD 125 LBS/FT' I STRUCTURAL NOTES 1. IT IS THE RESPONSIBILITY OF THE CUSTOMER/FACILITY TO HAVE AN ARCHITECT AND/OR STRUCTURAL ENGINEER OF RECORD DETERMINE IF FLOORING AND FLOORING SUPPORT STRUCTURE WILL ACCOMMODATE THE REQUIRED DSPECT GANTRY FLOOR LOADING, VERTICAL, AND HORIZONTAL FORCE SPECIFICATIONS. 2. SPECTRUM DYNAMICS WILL BE RESPONSIBLE FOR: 8. PROVIDING THE HILTI KBIII 5/8"0 ANCHOR HARDWARE FOR SEISMIC AND NON -SEISMIC APPLICATIONS. b. DRILLING/EMBEDDING OF ANCHORS AND MOUNTING SYSTEM 3. NON -SEISMIC EMBEDMENT=MINIMUM 2.75" 4. SEISMIC EMBEDMENT= MINIMUM 6" 5. IN THE EVENT THROUGH -BOLTING IS NECESSARY THIS WILL BE THE RESPONSIBILITY OF THE CUSTOMER/FACILITY TO COORDINATE THIS SERVICE. CUSTOMER'S APPROVAL SIGNATURE PRINT NAME 31-2111 2 1'-2'-" 8 C.G. WEIGHT=1,929 LBS (Y=29.6") �I(V _ M 00 =�.vr co -I W 00 Lo DATE n•� ■1�e1� 3is°HILTI KBIII 5/8"0 (QTY. 5) THREADED ROD (SEISMIC THRU-BOLT APPLICATION) Drawn by: Project: Date: DEREK LARSEN PROVIDENCE SWEDISH EDMONDS 06/13/2023 Scale: Client: Drawing Title: 1:20 SPECTRUM DYNAMICS SHEET TITLE: STRUCTURAL LAYOUT R e v i s i a n: C SYSTEM TYPE: DSPECT CARDIO Sheet: S1 S P E GTR[1 DYNAMICS MEDICAL