Loading...
APPROVED RESUB 1-BLD2024-0178+Plumbing_Plan+5.29.2024_5.57.51_PM+4289004NOTE FROM 2018 UNIFORM PLUMBING CODE 317.0 FOOD -HANDLING ESTABLISHMENTS. 317.1 GENERAL. FOOD OR DRINK SHALL NOT BE STORED, PREPARED, OR DISPLAYED BENEATH SOIL OR DRAIN PIPES UNLESS THOSE AREAS ARE PROTECTED AGAINST LEAKAGE OR CONDENSATION FROM SUCH PIPES REACHING THE FOOD OR DRINK AS DESCRIBED BELOW. WHERE BUILDING DESIGN REQUIRES THAT SOIL OR DRAIN PIPES BE LOCATED OVER SUCH AREAS, THE INSTALLATION SHALL BE MADE WITH THE LEAST POSSIBLE NUMBER OF JOINTS AND SHALL BE INSTALLED TO CONNECT TO THE NEAREST ADEQUATELY SIZED VERTICAL STACK WITH THE PROVISIONS AS FOLLOWS: (1) OPENINGS THROUGH FLOORS OVER SUCH AREAS SHALL BE SEALED WATERTIGHT TO THE FLOOR CONSTRUCTION. (2) FLOOR AND SHOWER DRAINS INSTALLED ABOVE SUCH AREAS SHALL BE EQUIPPED WITH INTEGRAL SEEPAGE PANS. (3) SOIL OR DRAIN PIPES SHALL BE OF AN APPROVED MATERIAL AS LISTED IN TABLE 1701.1 AND SECTION 701.2. MATERIALS SHALL COMPLY WITH ESTABLISHED STANDARDS. CLEANOUTS SHALL BE EXTENDED THROUGH THE FLOOR CONSTRUCTION ABOVE. (4) PIPING SUBJECT TO OPERATION AT TEMPERATURES THAT WILL FORM CONDENSATION ON THE EXTERIOR OF THE PIPE SHALL BE THERMALLY INSULATED. (5) WHERE PIPES ARE INSTALLED IN CEILINGS ABOVE SUCH AREAS, THE CEILING SHALL BE OF THE REMOVABLE TYPE OR SHALL BE PROVIDED WITH ACCESS PANELS TO FORM A READY ACCESS FOR INSPECTION OF PIPING. 705.6.2 SOLVENT CEMENT JOINTS. SOLVENT CEMENT JOINTS FOR PVC PIPE AND FITTINGS SHALL BE CLEAN FROM DIRT AND MOISTURE. PIPE SHALL BE CUT SQUARE, AND PIPE SHALL BE DEBURRED. WHERE SURFACES TO BE JOINED ARE CLEANED AND FREE OF DIRT, MOISTURE, OIL, AND OTHER FOREIGN MATERIAL, APPLY PRIMER PURPLE IN COLOR THAT COMPLIES WITH ASTM F656. PRIMER SHALL BE APPLIED TO THE SURFACE OF THE PIPE AND FITTING IS SOFTENED. SOLVENT CEMENT THAT COMPLY WITH ASTM D2564 SHALL BE APPLIED TO ALL JOINT SURFACES. JOINTS SHALL BE MADE WHILE BOTH THE INSIDE SOCKET SURFACE AND OUTSIDE SURFACE OF PIPE ARE WET WITH SOLVENT CEMENT. HOLD JOINT IN PLACE AND UNDISTURBED FOR 1 MINUTE AFTER ASSEMBLY. 709.0 GRAVITY DRAINAGE REQUIRED. 709.1 GENERAL. PLUMBING FIXTURES SHALL BE DRAINED TO THE SANITARY WASTE SYSTEM BY GRAVITY FLOW AND ARE PERMITTED TO BE PUMPED OR EJECTED AS ALLOWED PER SECTION 710.2 OR WHEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. 605.2.2 SOLVENT CEMENT JOINTS. SOLVENT CEMENT JOINTS FOR CPVC PIPE AND FITTINGS SHALL BE CLEAN FROM DIRT AND MOISTURE. SOLVENT CEMENTS SHALL COMPLY WITH ASTM F493, REQUIRING THE USE OF A PRIMER SHALL BE ORANGE IN COLOR. THE PRIMER SHALL BE COLORED AND SHALL COMPLY WITH ASTM F656. LISTED SOLVENT CEMENT THAT COMPLIES WITH ASTM F493 AND THAT DOES NOT REQUIRE THE USE OF PRIMERS, YELLOW OR RED IN COLOR, SHALL BE PERMITTED FOR PIPE AND FITTINGS THAT COMPLY WITH ASTM D2846, 1/2 OF AN INCH (15 MM) THROUGH 2 INCHES (50 MM) IN DIAMETER OR ASTM F442, 1/2 OF AN INCH (15 MM) THROUGH 3 INCHES (80 MM) IN DIAMETER. APPLY PRIMER WHERE REQUIRED INSIDE THE FITTING AND TO THE DEPTH OF THE FITTING ON PIPE. APPLY LIBERAL COAT OF CEMENT TO THE OUTSIDE SURFACE OF PIPE TO DEPTH OF FITTING AND INSIDE OF FITTING. PLACE PIPE INSIDE FITTING TO FORCEFULLY BOTTOM THE PIPE IN THE SOCKET AND HOLD TOGETHER UNTIL JOINT IS SET. 605.12.2 SOLVENT CEMENT JOINTS. SOLVENT CEMENT JOINTS FOR PVC PIPE AND FITTINGS SHALL BE CLEAN FROM DIRT AND MOISTURE. PIPE SHALL BE CUT SQUARE AND PIPE SHALL BE DEBURRED. WHERE SURFACES TO BE JOINED ARE CLEANED AND FREE OF DIRT, MOISTURE, OIL, AND OTHER FOREIGN MATERIAL, APPLY PRIMER PURPLE IN COLOR THAT COMPLIES WITH ASTM F656. PRIMER SHALL BE APPLIED TO THE SURFACE OF THE PIPE AND FITTING IS SOFTENED. SOLVENT CEMENT THAT COMPLIES WITH ASTM D2564 SHALL BE APPLIED TO ALL JOINT SURFACES. JOINTS SHALL BE MADE WHILE BOTH THE INSIDE SOCKET SURFACE AND OUTSIDE SURFACE OF PIPE ARE WET WITH SOLVENT CEMENT. HOLD JOINT IN PLACE AND UNDISTURBED FOR 1 MINUTE AFTER ASSEMBLY. 605.3.1 SOLVENT CEMENT JOINTS. SOLVENT CEMENT JOINTS FOR CPVC/AL/CPVC PIPE AND FITTINGS SHALL BE CLEAN FROM DIRT AND MOISTURE. SOLVENT CEMENTS THAT COMPLY WITH ASTM F493, REQUIRING THE USE OF A PRIMER SHALL BE ORANGE IN COLOR. THE PRIMER SHALL BE COLORED AND SHALL COMPLY WITH ASTM F656. LISTED SOLVENT CEMENT THAT COMPLIES WITH ASTM F493 AND THAT DOES NOT REQUIRE THE USE OF PRIMERS, YELLOW IN COLOR, SHALL BE PERMITTED TO JOIN PIPE THAT COMPLY WITH ASTM F2855 AND FITTINGS THAT COMPLY WITH ASTM D2846, 1/2 OF AN INCH (15 MM) THROUGH 2 INCHES (50 MM) IN DIAMETER. APPLY PRIMER WHERE REQUIRED INSIDE THE FITTING AND TO THE DEPTH OF THE FITTING ON PIPE. APPLY LIBERAL COAT OF CEMENT TO THE OUTSIDE SURFACE OF PIPE TO DEPTH OF FITTING AND INSIDE OF FITTING. PLACE PIPE INSIDE FITTING TO FORCEFULLY BOTTOM THE PIPE IN THE SOCKET AND HOLD TOGETHER UNTIL JOINT IS SET. 18 TO FORCEFULLY BOT 608.3 EXPANSION TANKS, AND COMBINATION TEMPERATURE AND PRESSURE -RELIEF VALVES. A WATER SYSTEM PROVIDED WITH A CHECK VALVE, BACKFLOW PREVENTER, OR OTHER NORMALLY CLOSED DEVICE THAT PREVENTS DISSIPATION OF BUILDING PRESSURE BACK INTO THE WATER MAIN, INDEPENDENT OF THE TYPE OF WATER USED, SHALL BE PROVIDED WITH AN APPROVED, LISTED, AND ADEQUATELY SIZED EXPANSION TANK OR OTHER APPROVED DEVICE HAVING A SIMILAR FUNCTION TO CONTROL THERMAL EXPANSION. SUCH EXPANSION TANK OR OTHER APPROVED DEVICE SHALL BE INSTALLED ON THE BUILDING SIDE OF THE CHECK VALVE, BACKFLOW PREVENTER, OR OTHER DEVICE AND SHALL BE SIZED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 1009.0 INTERCEPTORS (CLARIFIERS) AND SEPARATORS. 1009.5 LOCATION. EACH INTERCEPTOR (CLARIFIER) COVER SHALL BE READILY ACCESSIBLE FOR SERVICING AND MAINTAINING THE INTERCEPTOR (CLARIFIER) IN WORKING AND OPERATING CONDITION. THE USE OF LADDERS OR THE REMOVAL OF BULKY EQUIPMENT TO SERVICE INTERCEPTORS (CLARIFIERS) SHALL CONSTITUTE A VIOLATION OF ACCESSIBILITY. LOCATION OF INTERCEPTORS (CLARIFIERS) SHALL BE SHOWN ON THE APPROVED BUILDING PLAN. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE PIPING INSULATION SCHEDULE PIPING TYPE PIPING SIZE INSULATION TYPE INSULATION THICKNESS CONDUCTIVIT Y RANGE OVERHEAD COLD WATER ALL FIBERGLASS 1/2" - EXPOSED TO SIGHT COLD WATER ALL FIBERGLASS 1/2" - COLD WATER WITHIN WALLS NOT REQUIRED HOT WATER AND RECIRC (UP TO 140°F) 1/2" - 1-1/4" FIBERGLASS 1" 0.24-0.28 1-1/2" - 6" FIBERGLASS 1-1/2" 0.24-0.28 HOT WATER AND RECIRC (141 TO 200F) 1/2" - 1-1/4" FIBERGLASS 1-1/2" 0.25-0.29 1-1/2" - 6" FIBERGLASS 2" 0.25-0.29 HOT WATER UNDERGROUND 1/2 - 2 THERMA-CEL 1 0.24-0.28 HORIZONTAL COIL CONDENSATE PIPING ALL ARMAFLEX 1/2" - PIPE INSULATION SEC 2018 : SEATTLE ENERGY CODE TABLE C403.2.9 : MINIMUM PIPE INSULATION THICKNESS (INCH) FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES) TEMPERATURE RANGE AND USAGE (OF) CONDUCTIVITY BTU. IN./(H.FT2.OF)' MEAN RATING TEMPERATURE, OF <1 1 TO<12 12 TO<4 4 TO<8 >8 > 350 0.32 - 0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29 - 0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27 - 0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25 - 0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 1.5 40-60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20 - 0.26 50 0.5 1.0 1.0 1.0 1.5 A. FOR PIPING SMALLER THAN 1-1/2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESS BY 1 INCH SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B) BUT NOT TO A THICKNESS LESS THAN 1 INCH. B. FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED AS FOLLOWS: T = r{(1 + t/r)K/k -1 } WHERE: T = MINIMUM INSULATION THICKNESS, r = ACTUAL OUTSIDE RADIUS OF PIPE, t = INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE, K = CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE APPLICABLE FLUID TEMPERATURE (BTU.IN/H.FT2. °F) AND k = THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID TEMPERATURE C. FOR DIRECT -BURIED HEATING AND HOT WATER SYSTEM PIPING, REDUCTION OF THESE THICKNESS BY 1/2 INCHES (38 MM) SHALL BE PERMITTED BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B BUT NOT TO THICKNESS LESS THAN 1 INCH (25 MM). TEMPERING VALVE SCHEDULE PRODUCT TYPE VALVE, ASSE 1070 CERTIFIED LAVATORY TEMPERING BRAND CONTROLSTM MATERIAL BRASS CASTING WITH CORROSION RESISTANT INTERNAL COMPONENTS CORRECTIONAL, HOSPITAL & INSTITUTIONAL TREATMENT CENTER, EDUCATIONAL APPLICATIONS BUILDING, OTHER INSTITUTIONAL BUILDINGS COMMERCIAL WAREHOUSE, OFFICE BUILDING, APPLICATIONS STADIUM & ARENA, RESTAURANT & HOSPITALITY OUTLET TYPE COMPRESSION COMPLIANCE CSA; IAPMO FLOW RATE 4 GPM OVERALL HEIGHT: 3-1/4 IN, WIDTH: 3-1/4 IN DIMENSION STANDARDS ASSE 1070; CSA B125.3 INLET SIZE 3/8 IN OUTLET SIZE 3/8 IN TEMP. RANGE 850 TO 1150F MAXIMUM 125 PSI PRESSURE ELECTRIC WATER HEATER SCHEDULE EQUIP. UPC / INPUT TANK WATER MAXIMUM LOCATION MFG / MODEL NUMBER VOLTAGE WORKING WEIGHT TAG GTIN KW CAPACITY CONNECTION PRESSURE EHW-1 KITCHEN AO SMITH #LTE-120D 120 GALLON 6716572 4.5 119 3/4" 227V 150 PSI 268 LBS COMMERCIAL ELECTRIC WATER HEATER 36748 GALLON EXPANSION TANK SCHEDULE TANK SYSTEM STORAGE SUPPLY T&P TANK SIZE, IN EQUIP.TA G MANUFACTURER / MODEL CAPACITY VOLUME VOLUME SYSTEM D TEMP. (F) PRESSURE RELIEF SYSTEM DIAMETER HEIGHT (GAL.) (GAL.) (GAL.) (PSI) (PSI) (IN.) (IN.) ET-1 AMTROL / 34 435 300 140 80 150 16 45 BLDG HOT ST-70VC WATER APPROVED PLANS MUST BE BACKFLOW PREVENTER SCHEDULE TAG RPBA BRAND WATTS MODEL SERIES 009 1/2 IN. EPDXY COATED BRONZE FNPT 175 PSI BACKFLOW PREVENTER MATERIAL BRONZE COATING EPDXY DEPTH: DEPTH: 11-3/4 IN, LENGTH: 10 IN, HEIGHT: 4-5/8 IN FITTING SIZES 1/2 X 1-1/2 IN END CONNECTION 1 FNPT END CONNECTION 2 FNPT END CONNECTIONS FNPT x FNPT MAXIMUM PRESSURE 175 PSI TEMPERATURE MAXIMUM: 180, MIN: 33 VALVE SIZE 1/2 IN VALVE BODY STYLE INLINE VALVE OPERATOR: T-HANDLE VALVE BODY MATERIAL: CAST BRONZE ASSE STANDARDS: ASSE 1013 AWWA SPECIFICATIONS: AWWA C-511 BAA COMPLIANT YES CSA CERTIFIED: CSA B64.4 IAPMO LISTED: YES City Of Edmonds Building Department Work PLUMBING FOR NEW TI Address: 10000-10016 EDMONDS WAY Owner GYRO MAKERS 0 FAI D E S I G N S T U D 1 E] 9031 21 STAVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: PROJECT INFORMATION REVISIONS: zi 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 Approved Date 06/05/2024 SHEET# ON JOB SITE Building Official Erg Permit Number BLD2024-0178I P 1 36'-1 " 1 9'-9" 17'-4" 3' EXISTING WORK TABLE It o (E) E ELECTRICAL HAND NoF �F 24"X36" 6'-7" PANEL SINK MEAT SINK VEG SINK MOP SINK 3 C MP. INK - 8 = 17 18 19 - 20 TUL 16 `" `'' CLEAN NSTALL 48" A.F.F. SLASH GUARD BELOW GRADE TABLE" = BETWEEN VEG SINK AND MEAT SINK 25 GREASE INTERCE (N)FD T co 13 WORK TABLE 3' 12 13'-2" 30' X60" 6'0 \ 31-211z v ¢ K EXIT TO002 LASS K PORTABLE M PARKING 11 REACH -IN FIRE EXTINGUISHER M ' 3' FREEZER 54" r- \\ FIRE z 12 REACH -IN 23 xx 8 9 41 COOLER 54" Lu HAND SINK c� � 7 ow 5 U� o \ /I\/I 4 I= Ic a \ \ l0 9 Q W \ NEW UNISEX GRIDDLE / Ilo =o a (N)FD RESTROOM F- 36"X30" CoW c) > - 6 T zo w Z u � � z z_ GYR 2 Lu 5 -10 003 W w> 1 24 IN - 00 00 v T Eo XISTING POST 00 LASS K PORTABLE Q L " FIRE EXTINGUISHER J��PP1 L____ L o � 05 FIRE 5 4 a co Q 0 FIRE EXTINGUISHER 60 10 10 / 2-A:10-B:C RATED SANDWICH 25 > GRILL f \NEW SHORT WAL g� 3' 30"X48" 24 \ 30"X30" w� _E1 � J L L CD uj m O 30"X30" o Q 00 °° W >_ H WW="' C cm L 30"X48" z W � Z C7 W - L L W 7 7 F___ 7 F 30"X48" C. n T L L IL- L_ � pima INSTALL ACCESSIBLE EXIT SIGN. \ \ INSTALL A SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN MAIN ENTRANCE THIS SPACE IS OCCUPIED." N PROPOSED FLOOR PLAN (:?) SCALE: 1/4" = V-0" LEGEND (E) EXISTING FLOOR SINK (N) NEW O FLOOR DRAIN 0 FUNNEL FLOOR DRAIN 3' 3' 30"X48" 30"X48" M N 4'-10" WIRE SHELVING 24"X48" \ CD - M w I z J � 2X - Lu- 23 i�: 5% OF THE SEATING SHALL BE ACCESSIBLE 1„ AND DISPERSED THROUGHOUT THE DINING AREA. SHOW FOR ACCESSIBLE SEATING SPACES AS REQUIRED PER IBC 1108.2.9 INSTALL MAXIMUM OCCUPANCY LOAD SIGN "MAXIMUM OCCUPANCY 29 PERSONS." PLUMBING NOTE: PLEASE NOTE THAT THE FOLLOWING FIXTURES MUST DISCHARGE INTO THE GREASE INTERCEPTOR - KITCHEN FLOOR DRAINS - 3 COMPARTMENT SINK - MOP SINK - DUMP SINK - MEAT SINK HEALTH DEPARTMENT NOTE: NOTE: FULL HEIGHT STAINLESS STEEL PANEL WALL BEHIND ALL GLAZED DOORS TO HAVE .60 U-VALUES COOKING LINE, TYP. AND .45 SHGC VALUES NO CHANGE ON EXTERIOR WINDOWS 8'-0" HEIGHT FRP PANELS AROUND KITCHEN WALL, TYP. EXHAUST HOOD SYSTEM & FIRE SUPPRESSION SYSTEM BY OTHERS SHELVING: REFRIGERATORS: STAINLESS STEEL STEEL SHELVES; DRY STORAGE: LAMINATE/ WOOD; 5% OF THE SEATING SHALL BE ACCESSIBLE AND DISPERSED DRYING RACK: THROUGHOUT THE DINING AREA. SHOW FOR ACCESSIBLE SEATING STAINLESS STEEL; CHEMICALS SHELVING: SPACES WIRED RACK ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE ALL PAINT IN KITCHEN, PREP. AREA, AND SCULLERY AREA IS OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A SEMI -GLOSS. THERE'RE NO UNNECESSARILY EXPOSED UTILITIES. CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE BE ADVISED THAT THE NEW WASHINGTON STATE FOOD CODE "T-BAR CEILING, WASHABLE (WATERPROOF - USDA. FDA. HEALTH REQUIRED COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW (DOWN FROM 45 DEGREES) DEPARTMENT, CFIA APPROVED)" TOTAL 26 SEATS WALL LEGEND SYMBOL DESCRIPTION SEE DETAIL EXISTING WALL NEW INTERIOR FURRED OUT WALL W.1 PAGE A3 W 1 3-5/8" MTL. STUD 20GA. 16" O.C. W/$ TYPE "X" GWB ONE SIDE W'2 NEW INTERIOR PARTITION WALL W.2 PAGE A3 3-5/8" MTL. STUD 20GA. 16" O.C. W/$ TYPE "X" GWB BOTH SIDE W'3 NEW SHORT WALL (HEIGHT PER PLAN) H. PAGE A3 3-5/8" MTL. STUD 20GA. 16" O.C. W/$ TYPE "X" GWB BOTH SIDE EQUIPMENT SCHEDULE o z SUPPLIER z DESCRIPTION MANUFACTURER MODEL NUMBER DIMENSIONS (L.XD.XH.) ELECTRICAL PLUMBING GAS NOTES w z pq z o c� X LLI a Q = O z O o = o L3 w N z O BTU 1 X 1 DEEP FRYER AVANTCO #FF400 (16"X30"X48") 120000 2 X 1 GYRO MACHINE VISVARDIS #DG12V (23" X 27" X 33") 72000 3 X 1 COUNTERTOP GRIDDLE 36" AVANTCO #CAG-36-MG (36"X30"X17") 90000 4 X 1 2 BURNERS COUNTERTOP VOLLRATH CAYENNE #40736 HPG2-12 (12" X 27" X 14") 52,000 5 X 1 EQUIPMENT STAND 30"X60" REGENCY #600ES306OG (30"X60"X26") 6 X 1 EQUIPMENT STAND 30"X30" REGENCY #600ES303OG (30"X30"X26") 7 X 1 CLASS I HOOD 10'-0" BY OTHER 8 X 2 WALL MOUNTED HAND SINK ADVANCE TABCO #7-PS-40 (17"X1 5"X1 3") 1/2" 1/2" 2" DIRECT DRAIN 9 X 2 SANDWICH COOLER 60" AVANTCO #APT-60-HC (60"X31 "X43") 2.4 1/2 115 NEMA 5-15P 10 X 2 PANINI SANDWICH GRILL AVANTCO #P70S (1 7"X1 2"X1 0") 1750 18 120 NEMA 6-20P 11 X 1 REACH -IN FREEZER 54" TRUE #T-49F-HC (54"X30"X84") 9.6 1 115 NEMA 5-15P 12 X 2 REACH -IN COOLER 54" TRUE #T-49-HC (54"X30"X84") 5.4 1/2 115 NEMA 5-15P 13 X 1 WORK TABLE 30"X60" REGENCY #60OT306OG (60"X30"X34") 14 X 1 CLEAN DISH TABLE 36"X30" REGENCY #600CDT36L (36"X30"X45") 16 X 1 3 COMP. SINK REGENCY #60S3182418LX (79"X30"X44") 1/2" 1/2" 2" DIRECT CONNECT 17 X 1 1 COMP. SINK (LEFT DRAIN BOARD) REGENCY #60OS1 1 81818XLFT (39 X24 X44) 1/2" 1/2" 2" INDIRECT DRAIN 18 X 1 1 COMP. SINK (RIGHT DRAIN BOARD) REGENCY #60OS1 1 81818XRT (39 X24 X44) 1/2" 1/2" 2" INDIRECT DRAIN 19 X 1 WORK TABLE 24"X36" REGENCY #60OT2436G (36"X24"X34") 20 X 1 MOP SINK ADVANCE TABCO #9-OP-40 (25"X21 "X16") 1/2" 1/2" 2" DIRECT DRAIN 21 X 1 WATER HEATER AO -SMITH #LTE-120D 20 GALLON 22 X 1 WIRE SHELF 48"X24" REGENCY #460SW2448K75 (48"X24"X74") 23 X 2 WIRE SHELF 36"X24" REGENCY #460SW2436K75 (36"X24"X74") 24 X 1 SLIDING GLASS DOOR REFRIGERATOR 53" AVANTCO #GDS-47-HC (53"X32"X84") 3.14 1/2 115 NEMA 5-15P 25 X 1 PnQ . BY OTHER 26 X 1 GREASE INTERCEPTOR SCHIER #GB2 : 50 GPM (35"X23"X14") TOTAL 334,000 DOOR SCHEDULE DR# WIDTH HT. THK. DOOR MAT/FIN. DOOR TYPE REMARKS HARDWARE GROUP KEY NOTES 001 6'-0" 7'-0" 1-3/4" ALUM. FRAME/W GLAZING A* (EXISTING) EXTERIOR DOOR; MAIN ENTRANCE 1, 3, 5, 9, 11, 12,13 002 3'-0" 7'-0" 1-3/4" ALUM. FRAME B* (EXISTING) EXTERIOR DOOR ; REAR EXIT 1, 3, 5, 9, 11, 12,13 003 3'-0" 6'-8" 1-3/4" SOLID CORE WOOD C (NEW) INTERIOR DOOR RESTROOM 6, 10, 14 * THIS DOOR SHALL HAVE A SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." 1) ALL DOORS REQUIRED FOR ADA COMPLIANCE TO BE FITTED W/ APPROVED LEVER -TYPE HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. 2) MAX.1/2" THRESHOLD A.F.F. 3) THE ENTRY DOORS (DR#001,002) "MUST BE KEY -OPERATED LOCKING DEVICE FROM THE EGRESS SIDE". DOOR NOTE HARDWARE GROUP KEY NOTES 1. FINISH ALL WOOD DOOR/ WITH CLEAR COAT SUITABLE FOR EXTERIOR USE 1. PANIC HARDWARE 9. CLOSER 2. DOORS WITHIN THE PATH OF TRAVEL FOR HANDICAPPED TO BE OPENABLE WITH A SINGLE EFFORT BY LEVER, PANIC 2. PUSH BAR 10. KICK PLATE BAR OR PUSH/PULL HARDWARE. 3. EXTERIOR PULL HANDLE 11. WEATHER STRIP 3. EXIT DOORS TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 4. INTERIOR PULL HANDLE 12. THRESHOLD 4. DOOR CLOSER TO BE ADJUSTED TO PROVIDE FOR A MAXIMUM EFFORT TO OPERATE OF 15 LBF. AND PUSH PLATE 13. TOP & BOTTOM PIVOT 5. THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT 5. COMMERCIAL UNLOCKED 14. HINGE 6. BOTH SIDES OF DOORS SHALL BE FINISHED THE SAME, UNLESS OTHERWISE NOTED INDICATOR 7. ALL LEGAL EXITS SHALL BE PROVIDED WITH SELF-ILLUM EXIT SIGNS HAVING 6" LETTERS WITH 3/4" STROKES IN 6. PRIVACY, LEVER OPERATED CONTRASTING COLORS. HARDWARE 8. HARDWARE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER HARDWARE INCLUDING BACKSETS, STRIKES, ETC. 7. KEYED LOCKSET (SECURITY) 9. THE OPENING FORCE FOR ACCESSIBLE EXTERIOR DOORS SHALL NOT EXCEED 81/2 POUNDS FORCE. 8. RIM CYLINDER LOCK ROOM FINISH SCHEDULE # ROOM WALL CEILING FLOOR COVED BASE TILE COUNTER 1 KITCHEN / PREP AREA WATER RESISTANT GWB BEHIND PLUMBING FIXTURES 8' FRP AROUND WALLS TYP. / TILES T-BAR CEILING NON -SLIP CERAMIC TILE 4" COVED BASE TILE STAINLESS STEEL 2 RESTROOM WALL TILE T-BAR CEILING NON -SLIP CERAMIC TILE 4" COVED BASE TILE QUARTZ 3 DINING AREA GYPSUM WALLBOARD / PAINT T-BAR CEILING NON -SLIP CERAMIC TILE WOOD COVED BASE QUARTZ NOTE IBC 2018 : 803.11 LAMINATED PRODUCTS FACTORY PRODUCED WITH A WOOD SUBSTRATE. LAMINATED PRODUCTS FACTORY PRODUCED WITH A WOOD SUBSTRATE SHALL COMPLY WITH ONE OF THE FOLLOWING: 1. THE LAMINATED PRODUCT SHALL MEET THE CRITERIA OF SECTION 803.1.1.1 WHEN TESTED IN ACCORDANCE WITH NFPA 286 USING THE PRODUCT -MOUNTING SYSTEM, INCLUDING ADHESIVE, AS DESCRIBED IN SECTION 5.8 OF NFPA 286. 2. THE LAMINATED PRODUCT SHALL HAVE A CLASS A, B, OR C FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX, BASED ON THE REQUIREMENTS OF TABLE 803.13, IN ACCORDANCE WITH ASTM E84 OR UL 723. TEST SPECIMEN PREPARATION AND MOUNTING SHALL BE IN ACCORDANCE WITH ASTM E2579. REFERENCE ONLY OCCUPANCY LOAD: # ROOM NAME FLOOR AREA OCCUPANTLOAD FACTOR OCCUPANT LOAD 1 KITCHEN AND PREP AREA 550 SQ.FT. 200 GROSS KITCHEN 3 2 DINING AREA - TABLES AND CHAIRS 390 SQ.FT. 15 NET DINING 26 3 ACCESSORY USE 385 SQ.FT. - TOTAL 1325 SQ.FT. 29 MINIMUM PLUMBING FIXTURE CALCULATION: BASE UPON 2018 IBC : SECTION 2902 TABLE 2902.1 GROUP OF OCCUPANCY: B - RESTAURANT TOTAL OCCUPANCY = 29 FIXTURE REQUIRED PROVIDED 1 PER 75 WATER CLOSET 29 OCC /75 : REQUIRED = 1 1 URINAL FOR MEN'S FACILITY SERVING 26 OR MORE PERSON, NOT LESS THAN 1 URINAL SHALL BE PROVIDED 1 29 OCC : REQUIRED = 1 1 PER 200 LAVATORY 29 OCC /200 : REQUIRED = 1 1 2� ADA COUNTER HEIGHT 34" THE TOPS OF COUNTER AND WORK SURFACES SHALL BE 0 34 INCHES MAXIMUM FROM THE FLOOR OR GROUND. 8" MIN. 306.2.3 MINIMUM DEPTH. WHERE TOE CLEARANCEIS x REQUIRED AT AN z ELEMENT AS PART OF A CLEAR FLOOR SPACE M N COMPLYING WITH z a' SECTION 305, THE TOE CLEARANCE SHALL 11" 1, 6" 1, EXTEND 17 INCHES (430 MIN"l MM) MINIMUM BENEATH THE ELEMENT. A ADA TABLE DETAIL SCALE : B ADA COUNTER DETAIL SCALE: N.T.S. N.T.S. EK =T MAXIMUM OCCUPANCY NOT TO EXCEED .§.80 8 NOTE: PERSONS IBC 1013.4, "RAISED CHARACTER AND BRAILLE EXIT SIGNS" "A SIGN STATING EXIT IN VISUAL CHARACTERS, RAISED CHARACTERS, AND BRAILLE, AND COMPLYING WITH ICC ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY OR RAMP, AN EXIT PASSAGEWAY, AND THE EXIT DISCHARGE. D RAISED CHARACTER AND N T"SE C OCCUPANCY LOAD SIGN NTSE BRAILLE EXIT SIGNS 1� FIG. 308.2.1 (A) UNOBSTRUCTED FORWARD REACH x a G 00 Z n UNOBSTRUCTED HIGH SIDE REACH nnu nnnV Q 00 FIG.308.2.2 (B) OBSTRUCTED HIGH FORWARD REACH WE � a 00 v r 10" MAX. (A) FIG.308.3.1 OBSTRUCTED HIGH SIDE REACH FIG. 308.3.2 ICC A117.1 - 2009: TABLE 603.6 - MAXIMUM REACH DEPTH AND HEIGHT MAXIMUM REACH FIG. 308.2.1 (A) UNOBSTRUCTED FORWARD REACH x a G 00 Z n UNOBSTRUCTED HIGH SIDE REACH nnu nnnV Q 00 FIG.308.2.2 (B) OBSTRUCTED HIGH FORWARD REACH WE � a 00 v r 10" MAX. (A) FIG.308.3.1 OBSTRUCTED HIGH SIDE REACH FIG. 308.3.2 ICC A117.1 - 2009: TABLE 603.6 - MAXIMUM REACH DEPTH AND HEIGHT MAXIMUM REACH 0.5" 2" 5" 6" 9" 11" DEPTH (13 mm) (51 mm) (125 mm) (150 mm) (230 mm) (280 mm) MAXIMUM REACH 48" 46" 42" 40" 36" 34" HEIGHT (1220 mm) (1170 mm) (1065 mm) (1015 mm) (915 mm) (865 mm) E ICC A117.1 - 2009 : SECTION 308 REACH RANGES SCALE : I D E S I G N S T U D 1 a 9031 21 ST AVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: FLOOR PLAN (FOR REFERENCE ONLY) REVISIONS: 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# P2 1-1/2"0 VENT (7 DFU) \ owFJr 3 COMP SI 14 WCO-+ I TABLE 36"X30" N o N � I I I )� I PA E I I T 1 WCO HOOD WALL; NO COMBUSTIBLES IN WALL NO PLASTIC PIPING AND WIRING D E S I G N S T U D 1 E] 3" VENT THROUGH ROOF CONNECT TO EXISTING SANITARY WASTE LINE BELOW GRADE. 9031 21STAVE SW SEATTLE, WA 98106 2"0 VENT (7 DFU) TEL. 206.322.4323 FIELD VERIFY BY LANDLORD FAX. 206.322.9177 1 COMP SINK 1 COMP SINK E-MAIL: INFO@CATCHSTUDIO.COM WCO (MEAT) 2 DFU (VEG)2 DFU WWW.CATCHSTUDIO.COM -- — — —— GWN GW-- FD 2" 0 3 0 GW (N)FD 2 DFU I 5 DFU 2"0SW 2 DFU N =Sw =sw- 8 D 2 DFUK O GRIDDL 36"X30' GYR 24 w-q- Q� =UJ UJ � J LU CD U 30"X30" 30"X30" �U) 2 1 11 REACH -IN FREEZER 5, 9 2 O U_ Co DLu � Q L1J zJ Qo C/) o U 9 > =o U co ow zJ QC) U) o U 5 QOO�P' GWGW—GW Qo � SANDWICH 25 /� > GRILL ' 13 '> w o WCO z w > CD N T T \ / WIRK TABLE 124"X36" r W MEAT K V G `6 DFU I W SW =SW i SW=SW �$ 18 4 DFU yy pip GW—GW �/� GA .I JL � I� /�1RU GW BETWEEN EG SINK ANC JEAT SINK '0GW DFU I I SANITARY WASTE LINE TOTAL 9 DFU / 3" 12 RppEACHAt 3"9 UrV 54 — 2"0SW 3 5 DFU,- SW U �� s per� (N)�F++ D �� RE, , 0 NpFU 1 DFU \ ' 1� I � I � I � 0w -- 24 IN I z I I I � I I I � I � I I I I I I I STING POST 30"X30" --------- I �I I I I I w I � I : co L------ 307�48" - - - - I 3011X48" I F1-1 30"X48" 30"X48" 1 20 SW GW—GW ` 21)1 3"0GW- 10 DFU EXISTING \' WATER I TT ISW -f DFU S 0b0o0 =000 0 SW 0o00000000 000 000000000� 0000 000, DQ.00D0a09Q000 CONNECT TO EXISTING SANITARY WASTE LINE. FIELD VERIFY EXACT LOCATION BY CONTRACTOR. IIIIIIIIIIIIIIIIIIIIIIIIIII �191i3:I�:GILIIl'�1►�.11111 ' IIIIIIiIYll�ll�lllllllllll � � 1 IIIIIIIIIIIIIIIIIIIIIIIIIII V11S__ PROVIDED FULL-SIZE 4" CLEAN -OUT AT DISCHARGE LINE FROM GREASE INTERCEPTOR PROPOSED GREASE INTERCEPTOR SCHIER #GB2 (50 GPM) BELOW GRADE SEE SPEC SHEET ON PAGE P6 SANITARY WASTE LINE (BASE UPON 2018 UPC) QTY. TRAP SIZE F/U EACH F/U TOTAL FIXTURE NAME 1 2" 1 1 LAVATORY 1 2" 4 4 WC. 1 2" 2 2 URINAL 1 2" 2 2 FLOOR DRAIN 9.0 TOTAL OF DRAINAGE F/U SEWER LINE (BASE UPON 2018 UPC) QTY. TRAP SIZE F/U EACH F/U TOTAL FIXTURE NAME 2 2" 2 4 HAND SINK 1 2" 2 2 FLOOR SINK 1 COMP. SINK 6.0 TOTAL OF DRAINAGE F/U WASTE LINE TO GREASE INTERCEPTOR (BASE UPON 2018 UPC) QTY. TRAP SIZE F/U EACH F/U TOTAL FIXTURE NAME 1 2" 2 2 FLOOR SINK 1 COMP. SINK 1 2" 2 2 FLOOR DRAIN 1 2" 3 3 MOP SINK 1 2" 3 3 FLOOR SINK 3 COMP. SINK 10.0 TOTAL OF DRAINAGE F/U SYMBOL ABBREV. DESCRIPTION (E) EXISTING PIPE TO REMAIN —G— G. NATURAL GAS —HW— HWS HOT WATER SUPPLY ---- HWR HOT WATER RETURN :CW— CW COLD WATER SUPPLY — FW — FW FILTER WATER :SW— SW SANITARY WASTE —GW— GW GREASE WASTE V VENT PIPE —CD— CD CONDENSATE DRAIN HYDROMECHANICAL GREASE INTERCEPTOR (HGI) SIZING CHART DFU HGI FLOW (GPM) 8 20 10 25 13 35 20 50 35 75 172 100 216 150 342 200 428 250 �N _. WASTE AND VENT PLAN SCALE3,'8' = 1.-0" RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: WASTE AND VENT PLAN REVISIONS: zi 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# P3 AUTOMATIC DISHWASHER ELIMINATED 1 INSTALL WATER HAMMEM ARRESTER PER 609.10 UPC CLEAN TAE )G11nil I = I I � 002 EXIT TO lE PARKING = -INSTALLED TEMPERING VALVE AT HAND SINK. SEE SPEC SHEET ON PAGE P7 TRAP PRIMER 1/2" COLD WATER LINE (GRAVITY) FROM TRAP PRIMERS PER 1007.1 UPC 2018. SEE TRAP PRIMER SPEC SHEET ON PAGE P7 SHUT OFF VALVE WORK TABLE I 11 EXISTI G F � 24"X36" T VEG SINK T MO SI WI wj W HW w cw cw IN TA L 48" A.F.F. SLASH GUt" N VEG "ND MEAT SINK �� 3� 0o Lo o cy") Lcc _ _ aLu _ o I o REACH -IN o N HW 1 1 (W�F 2 54" _ I � I 11 L I LL.I 1 RrVI 8 9 12 CO4" Lu 2 WSFI�D "� � �M INSTALLED TEMPERING VALVE AT � w w w W HAND SINK. SEE SPEC SHEET ON PAGE P7 5 0 7 Qo �� WSFU 1 --2 WS i U) o CC� 1G-1--- N cc ------i CD 1 IMIII, GRIDDL (N)FDj',' R Lu 36"X30' o co '' ` U ` HOOD WALL; NO COMBUSTIBLES I zo LAV WALL. NO PLASTIC PIPING AND WIRING ° �� 1 WSFU GYR 2 �I INSTALL POINT OF USE HERMOSTATIC" 24 IN z ELECTRICAL TAN SS HOT WATER HEATER ACC MIX MOI L.#AM012240T co INSTALL CHECK VALVE ON COLD WATER SUPPLY 1 COMP SINK 1 COMP SINK MOP SINK (MEAT) 2 WSFU (VEG)2 WSFU 3 WSFU P QnoQ \; Exls��jj 51N I ° ELE�T�SFU PANEL SI1K MEAT SI HW H HW HW HW W I H cw cw cw Iw cw II I I 1/2 COLD WATERLINE _ I (UNDER FLOOR) `F M `� N FD `L `L I � � TRAP PRIMER WORK 13 3 x ILI I T T co N = U 2 U I J CJ�O� Q�5 QOp,P 10 (10 SANDWICH 25 GRILL ' 24 w cD Ln QCC =w w CD mL) U 30"X30" 30"X30" 4 J ISTING POST 30"X30" -I I I I I I W I � I 0 I � I '------ 30-X48" F- I 30"X48" I F W_ I = I I I I I I I I I I 30"X48" 30"X48" 30"X48" CONNECT TO EXISTING 1-1/2" WATER INCOMING LINE. FIELD VERIFY THE EXACT LOCATION BY LANDLORD. COLD WATER 1" (18.5 WSFU) HOT WATER 1" (13 WSFU) MINIM 11w MINIM 00 [5- off 111 MISSION ■ • ■ TF-7 .','.� •:' I����� .TOR �� ■=r��� ■����MINIM PROPOSED ELECTRIC WATER HEATER 00 A1 11 120 GALLON POTABLE WATER: COLD WATER (BASE UPON 2018 UPC : CHAPTER 6 TABLE 610.3) QTY. TRAP SIZE F/U EACH F/U TOTAL FIXTURE NAME 2 2" 2 4 HAND SINK 2 2" 2 4 1 COMP. SINK 1 2" 2 2 3 COMP. SINK 1 2" 3 3 MOP SINK 1 2" 2 2 URINAL 1 2" 1 1 LAVATORY 1 2" 2.5 2.5 WC. 18.5 POTABLE WATER: HOT WATER (BASE UPON 2018 UPC : CHAPTER 6 TABLE 610.3) QTY. TRAP SIZE F/U EACH F/U TOTAL FIXTURE NAME 2 2" 2 4 HAND SINK 2 2" 2 4 1 COMP. SINK 1 2" 2 2 3 COMP. SINK 1 2" 3 3 MOP SINK 13.0 SYMBOL ABBREV. DESCRIPTION (E) EXISTING PIPE TO REMAIN —G— G. NATURAL GAS —HW— HWS HOT WATER SUPPLY ---- HWR HOT WATER RETURN :CW: CW COLD WATER SUPPLY — FW — FW FILTER WATER sW _ SW SANITARY WASTE —GW— GW GREASE WASTE V VENT PIPE —CD— CD CONDENSATE DRAIN POTABLE WATER RISER PLAN f SCALE: 3/8= 1-011 D E S I G N S T U D 1 E] 9031 21 STAVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: POTABLE WATER PLAN REVISIONS: zi 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# P4 A COMMERCIAL ELECTRIC WATER HEATER SPEC SHEET B ELECTRIC WATER HEATER TYPICAL DETAIL D E S I G N S T U D 1 a It CeSmithe COMMERCIAL ELECTRIC WATER HEATERS LIGHT -SERVICE COMMERCIAL ELECTRIC WATER HEATERS Designed for light duty commercial applications with intermittent hot water loads. GLASSLINED TANK ENHANCED -FLOW BRASS DRAIN • Tank interior is coated with glass VALVE specially designed by A. 0. Smith for • Solid brass, tamper resistant, water heater use enhanced -flow, ball type, drain valve HEATING ELEMENTS MAXIMUM WORKING PRESSURE 150 PSI • Two 6.1 KW zinc plated copper sheathed elements are standard FACTORY INSTALLED CSA CERTIFIED AND ASME RATED STANDARD VOLTAGES TEMPERATURE AND PRESSURE • The standard voltage is 277V single RELIEF VALVE phase CERTIFIED TO UL 1453 FOR COMMERCIAL ELECTRIC WATER TOP MOUNTED JUNCTION BOX HEATERS CONTROLS COMPLIANCE • Thermostat is adjustable through a . Meets the standby loss requirements range of 120' to 181°F with a manual of the U.S. Department of Energy and reset high temperature cutoff. The current edition ofASHRAE/IES 90.1 heater is wired for simultaneous single phase operation. WARRANTY COREGARDT"ANODE ROD • 6-Year limited tank/1-Year limited parts • Our anode rods have a stainless steel • For complete information consult the core that extends the life of the anode rod allowing superior tank protection written warranty or hotwater.com for longer than standard anode rods ® January 2022 A. 0. Smith Corporation. All rights reserved. www.hotwater.com 1 800-527-1953 Toll -Free USA I A. 0. Smith Corporation 1 500 Tennessee Waltz Parkway I Ashland City, TN 37015 C I WATER HEATER TYPICAL INSTALLATION NOLDMF�' QUICKgmw INSTALLATION INSTRUCTIONS. - Wall coverings may conceal electrical wiring or pipes, which may cause damage or serious injury if punctured by drills or fasteners. Unless you are confident that there will be no interference from such obstacles, we recommend that you seek qualified help when installing this product. INSTALLER: WEAR GLOVES & PROTECTIVE EYEWEAR WHEN INSTALLING THIS PRODUCT. "Caution: Strap coil is under tension. Box Contents BOX CONTENTS: 4 - Straps 4 - J-Clips 4 - Lag bolts 1/4" x 2 1/2" Self -drilling with 1/4" washers 2 - 3/8" bolts, washers, nuts TOOLS NEEDED: • 3/8" socket or wrench for tightening at wall • 9/16" wrench for tightening strap and J-Clips Optional: Drill with 1/8" drill bit Check the water heater. If the water heater is not a zero clearance unit (as specified on the rating plate), see instructions inside box on how to build a spacer. Select location for water heater. Figure A The best place to locate your water heater is directly in front of a 2" x 4" wall stud. See Figure A. Figure B The straps must be installed in the upper and lower 1/3 of the water 1/3 heater. The lower strap must be at least 4" above the water heater's controls. See Figure B. Mark the wall studs on both sides a" MIN 1/3 1 of the water heater where you will f� install the straps. Drill 1/8" pilot holes u if desired. Page 1 of 2 AOSCE15701 WATER HEATER RESTRAINT BRACKETS Self -Drilling Lag It is not necessary to pre -drill a pilot hole for the lag bolt. a Figure D Select one strap . Install one J-Clip per - Figure E (Strap "A") Hold strap "A" so Fig re C that the J-Clip is in the approximate center of the water heater. See Figure C. Select a mounting hole that best aligns with the pilot mark on the stud; secure the end of the strap to the stud with a 1/4" x 2 1/2" lag bolt and washer. See Figure D. a Strap I Figure E Btmp"A" APpma _ Figure G a.. ----- -- --°Figure F Install strap "B" (See Figure E) on the opposite side of the heater; select a mounting hole which allows a few inches of strap "B" to pass behind Strap "A", and secure Strap "B" to the wall. Insert a J-Clip into the slots of Strap "B". The longer side of the J-Clip must be towards the end of the strap, so that it is approximately 3" from the J-Clip on Strap "A", when the two J-Clips are pulled together snugly. See Figure F. Hint: If Strap "A" is too long, simply re -position the J-Clip then bend the strap behind the J-Clip as shown in Figure G. Secure the two J-Clips together with 3/8" carriage bolt, nut and washer, and tighten. Repeat the entire installation process for the second pair of straps using the same hole and slot positions as the first installation. If necessary, trim strap ends at the wall. Installation Complete DSA APPROVED cSmith COMMERCIAL � ELECTRIC WATER HEATERS T&P VALVE ACCESS PAN EL ACCESS PAN EL DRAIN VALVE PRODUCT SPECIFICATIONS i i ANODE JUNCTION BOX T&P VALVE Model Number Gallon Capacity Standard Element Wattage Dimensions in Inches Approx. Shipping Weight (Ibs) A B C Diameter D LTE 66D 66 6100 60-1/4 53 22 8 146 LTE 80D 80 6100 60-1/2 52-1/4 24 8 175 I I LTE 120D 1 119 1 6100 1 61-1/2 54-1/2 28 8 268 Not available with top mounted T&P valve option. Inlet and outlet connections: 3/4" RECOVERY CAPACITIES Element Wattage (Upper/Lower) Input kW U.S. Gallons/Hour and Liters/Hour at Indicated Temperature Rise of 36 40 54 60 72 80 90 100 108 120 126 °C 20 22.2 30 33.3 40 44.4 50 55.5 60 66.6 70 6100/6100 12.2 GPH 140 126 93 84 70 63 56 50 47 42 40 LPH 531 478 354 318 265 239 212 191 177 159 152 Standard factory wiring is for simultaneous operation. SPECIFICATION The water heaters(s) shall be model(s) No. as manufactured by A. 0. Smith or an approved equal. Heaters) shall be rated at kW, volts, single-phase, 60 cycle AC, and listed by Underwriters' Laboratories. Models shall meet the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IES 90.1. Tank(s) shall be gallon capacity. Heater(s) shall have 150 psi working pressure and be equipped with an extruded high density anode rod. All internal surfaces of the heater(s) exposed to water shall be glasslined with an alkaline borosilicate composition that has been fused -to -steel by firing at a temperature range of 1400°F to 1600°F. Electric heating elements shall be zinc plated copper sheath. Each element shall be controlled by an individually mounted thermostat and high temperature cutoff switch. The outer jacket shall be of baked enamel finish and shall enclose the tank with foam insulation. The drain valve shall be located in the front for ease of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Fully illustrated instruction manual to be included. C January 2022 A. 0. Smith Corporation. All rights reserved. www.hotwater.com 1 800-527-1953 Toll -Free USA I A. 0. Smith Corporation 1 500 Tennessee Waltz Parkway I Ashland City, TN 37015 PRODUCT SPECIFICATION DRAWING QUICK STRAP® #QS-120 Seismic support for water heaters 54" 11/2" 00000000000000 o o o o o o o o• Carriage Bolt, #3/8-16 x 3.0" long 3/8" Hex Nut Lag Bolt, #1/4-10 x 2-1/2" Long J-Clip Page 2 of 2 AOSCE15701 ALL DIMENSIONS IN INCHES The QUICK STRAP@ #QS-120 is a seismic/earthquake support system for water heaters up to 120 U.S. gallons in size. The system includes: (4) Straps, (4) J-Clips, (4) Lag Bolts, (2) 3/8" Carriage Bolts and (2) 3/8" Hex Nuts. The Quick Link@ system allows for full adjustment from the front side of the water heater. Product Information: • Material: Strap, 24 gage CRS, galvanized • California Division State Architect (DSA) approval #98-018 • UPC / IPC / IAPMO listed HIS INFORM IETARY TO HOLDRITE AND IS SUBJEC TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. NOLOL-- n U CONVERTING VAKE,SHIF F METHOCS INTO ENGINEERED SOLUTIONSL" 800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM spec_QS-120_RevM STATE RCMIWRNIA t `pcgU wmplles with lPC v�• U ACCEPTABLE PC METHOD No. 98-018 Product Submittal lJobName: 2X6 METAL STUD @16" OC. FULL HEIGHT WALL TEMPERATURE AND PRESSURE RELIEF VALVE VACUUM BREAKER HEAT TRAP 6" MINIMUM HOT WATER OUTLET TO FIXTURES QUICK STRAP #QS-120 WITH CARRIAGE BOLT, 3/8"-16x3.0" LONG, LAG BOLT 1/4"-10 x 2-1/2" LONG , 3/8" HEX NUT AND L-CLIP RELIEF VALVE DISCHARGE LINE (PIPED TO SUITABLE DRAIN AS ILLUSTRATED) 6" AIR GAP DRAIN PAN PIPE TO SUITABLE DRAIN SCALE : N.T.S. 2018 UPC : TABLE 610.3 ELECTRICAL JUNCTION BOX (USE ONLY COPPER CONDUCTORS) UNION ANODE ELECTRICAL WATER HEATER FINISHED FLOOR AUXILIARY CATCH PAN 2" MINIMUM UNION TO ELECTRICAL DISTRIBUTION PANEL HEAT TRAP TO COLD 6" MINIMUM WATER SUPPLY -\SHUT-OFF VALVE I THERMAL EXPANSION TANK ET-1 : AMTROL / ST-70VC JACKET ACCESS PANEL JACKET ACCESS PANEL DRAIN VALVE INCOMPRESSIBLE R-10 INSULATED PAD UNDER ELECTRIC WATER HEATER NOTE: PROVIDE AN INCOMPRESSIBLE INSULATED PAD WITH A MINIMUM THERMAL RESISTANCE OF R-10 UNDER ALL ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FLOOR. WATER SUPPLY AND DiSTfliau ON TABLE 610.3 WATEA SUPPLY FIXTURE UNITS (WSFU) AND MINIMUM FIXTURE BRANCH PIPE SIZES' MIt41Mi/M FiXTUFiE APPLIANCES, APPURTEISANGES OR FIXTURES' @RANG/r MIRE StZE' 4 PRIVATE PU8IIC 455LSRElLY• I,nchetl bathtub or Cuutbututm Bath. Sbowct If IW 1 4.0 I ''• Inch finthluh l Ill VAKU 1410 I I Ifidct 1.0 - - I.-Il 11'1OL-1 4,o 4A Dental Una. cwpukx - 1.0 - Dt+htt ulwr, 1.5 DnAing Foualum m Whici CmIcr 0.5 03 0.73 Haw Hthh '.h 2.5 2.3 - llow Bibb. rachaddilioaar 1,0 I'D Lavatory -- ',i 1.0 I'D Ln I _A%N n S-,Vinft ley, each brat (Al htabtle Home. etch nllinn - - Sinks liar � II �.Q Chuical Faucet 3.0 - ClImILal rluARNMer I I 9.0 - Kilahrn.Illmle>licti`i' Laundry t ' LS - w1cr ur Mile W.Ul 1 I) - Washup, each art 01.11 -.0 - Show;r. perheud 21) - L_rtnall- 1.11 UP1. 11tl:iuffltil atnotc - - i'rtttatl• grealta Ibat't 1 A Gl i .wnn�c' U u iaL (lush tank _ 2.11 3,u 1 initial, Hvhrtd 1 11 IV I Waah Nntntnia. circular Wmc + 40 - Walef Uloicl. 1.6 tl3PF Omvuy'lank 2.3 23 Wafer Clown. 1 A (TPF Flu0mienrtor Tank '. 3.5 2 S V5 Waiti Ciowt. 1.6 GPF Fluslwwcter �tltc I tee Vexomeet - Wbier t town. grater th"ut I h clrl' t iravrty IN* '. S." 3 3 7.0 Waier (-I"1_ gn vAci than 1 A GPF Flus arncleT VAI%r I sec �Omnarw pl Ir it ulltt%' 1 Inch - '4� thin Nunn. lm- W the cute brw0i plpt or bath tbt Nit and told 4timb pope. Appl is vim *ppu uTww qL or fiunurt not mirmw Ld in chi. InNe shalt: he prm mined in he sand by refem"m to fietum • 'cac irl n similar flow rate ant frr- yucury W use ' I fie Iloal .loner► wlit valuec rcprr.em rdtrir Ir.n1 rn rhr tvrlr �vatrr hniktint .u(�+11 I hr trparur ci-M wooer and lun wale ftttt im Iwtn .slur ltw tivnum hoc - mg Will hat SW outlt: tvAla cunlicaloiitt d au N. -,wmiucd w he cub tAca its durc•1ltrtrbt Id the Wcd tows value of Uit fimm ' The (bled Imuumum t.uppiv brunch pipe straw lot Individual Rumen we the tumumel ILU.I PLpc nuc. • Err flmrrc er cuPPIN : cmnrnurn. t,krly to ImPIrW ; am117urur flaw derna.wll deammiwr rhr nocutrM Alter in CaNwd par rcrtnatle Iami t 1 ..1. mit add it .ep- amid) it- the di=Acd in spry (L-o l fur tlu di•tribauon syxie a or portluna lbervM& kmer ray ; rubllc (Isc (Soc I &* 4_`.'111 0ANffe turng ISudtnmctcr %yacaaM., wee'S"don a11) 111, ' Roduccd IWiee unit loodutg lcc t"Liuuat hrye blabs Is w be aicd whets Lung wwl blcldt-•1g &M w! mad Gn P:pe aunty A-hde wrc t:cctr true dux brbb :c tnp(�i red Fti r ;rlmem n1 wnn r it err frotTnn pipe the tivurr hrnnrh to each burr hrbh Anit hr oA-d rro the havia :r(tmim trrrnc 2018 UNIFORM PLUMBING CODE 1111 9031 21 ST AVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: SPEC SHEET REVISIONS: ZI 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# P5 D I GREASE INTERCEPTOR SPEC SHEET 1D E S I G N S T U D 1 O SPECIFICATIONS Notes: 1. 4" FPT inlet/outlet with 3" and 4" plain end fittings. 2. Unit weight - 49 lbs. (wet weight 216 lbs.) 35" "A" 12-7/16" 3. Maximum operating temperature: Outlet 1500 F continuous (Optional) 4. Capacities - Liquid: 20 gal. p�p�p�p�p�p"o" o 0 Grease: 130 lbs. (17.8 gal.) @35 GPM Grease: 127 lbs. (17.3 gal.) @50 GPM O O O O O 000 000000� 0 0 0 00 ®0000000000 Grease (99% - at least 2 units in series): 180 lbs. (24.7 gal.) O O O % o ® 0000 ® % % % % % @35GPM A %0%0%0% 0000 %O%ODO% Solids: 1.8 gal. 5. 6. Built-in flow control. For drainage 0 0 0 �O�O%O O O O 7. gravity applications only. ---- Do for -4-�?-�-- -- -- - - - -- -----p-�-a 8. not use pressure applications. Inlet Cover full to tank for �O�O�O °0%0%0% placement allows access � %0%0%0 9. proper maintenance. Vent not required unless per local code. eeO �O�O�O�O 0�000� 10. Engineered inlet and outlet diffusers are Do0%0%a%0% 11. removable to inspect/clean piping. Integral air relief / anti -siphon. % 01Z4 0 Oa0o0o0o4e0a0a 0 000000 aoa0o0o0o0a010% 12. Designed for indoor, on -floor, below -grade or low -profile under sink installations. Outlet "C" ENGINEER SPECIFICATION GUIDE (Optional) Schier Great Basin TM grease interceptor model # G62 shall be lifetime guaranteed and made in USA of TOP VIEW seamless, rotationally -molded polyethylene with minimum (COVER REMOVED FOR CLARITY) 5/16" uniform wall thickness. Interceptor shall be furnished for above or below grade installation. Interceptor shall be certified to ASME Al 12.14.3 (type C) and CSA B481.1, with field cut riser system, built-in flow control and three outlet options. Interceptor flow rate shall be 35 or 50 GPM. Interceptor grease capacity shall be Flow Control 130 lbs. @ 35 GPM or 127 lbs. @ 50 GPM. Cover shall provide water/gas-tight seal and have minimum 450 lbs. of 4" FPT 021-1/2" Cover See Note #11 Inlet and Outlet load capacity. CERTIFIED PERFORMANCE 5„ Great BasinTM hydromechanical grease interceptors are third party performance -tested and listed by - - - IAPMO to ASME #A112.14.3 and CSA B481.1 I grease interceptor standards and greatly exceed requirements for grease separation and storage. 8-3/4" They are compliant to the Uniform Plumbing Code, In the National Standard Plumbing Code, the National Plumbing Code of Canada, and the International Plumbing Code. Engineered Inlet and Outlet Diffusers Satisfies Miami DERM 99% efficiency requirements when at least 2 SECTION A -A units are installed in series. Product labels are permanently attached COUNTY to inside and outside of unit for easy viewing. MODEL NUMBER: GB2 PART NUMBER: 4065-001-05 DESCRIPTION: GB2 GREASE INTERCEPTOR 35 GPM / 50 GPM, 4" FPT INLET/OUTLET, WITH 3" AND 4" PLAIN END FITTING ADAPTERS AND PEDESTRIAN RATED COVER PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SCHIER PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SCHIER PRODUCTS PROHIBITED.ED. Is DWG BY: C.SINCLAIR DATE: 5/5/2022 REV: - ECO. E GREASE INTERCEPTOR TYPICAL INSTALLATION INSTALLATION GUIDE GB235/50 GPM Grease Interceptor for Indoor Use ® ® ® ®® 6 00 0 0 0 ®® ®®c e Contents 000®oo o o o0 0�0 oD�r__ 0 2000 0 0 0 0 0 aR Special Precautions ........................................ 2-3 Getting to Know the GB2.....................................4 On the Floor Installation .................................... 5-7 Buried Installation ........................................ 8-10 LIFETIME GUARANTEED GREASE INTERCEPTORS 913-951-3300 1 schlerproducts.com © Copyright 2023 Schier Products Company, OV01/23 Outlet "B" (Standard) Outlet Foot Must Face This Direction In All Configurations 6-3/4" INVERT Water Line 13 ISOMETRIC VIEW END VIEW ®SCHIER U P C U P C 6466 Woodland Dr Shawnee, KS 66218 Tel: 913-961-3300 )(R-) C ® Fax: 913-961-3399 schierproducts.com Installation Instructions Installation instructions and additional components are included with the interceptor. Read all instructions prior to P installation. This interceptor is intended to be installed by a licensed plumber in conformance with all local codes. When Installing Interceptor Inside If your dishwashing sink(s) discharges into a floor drain/sink (drain), you must regulate the flow into the drain to avoid an overflow of water onto the kitchen floor. This can be done by installing a valve or flow restriction cap on the sink piping that discharges into the High Temperature Kitchen Water If water is enteringthe interceptor at excessive temperature over 150 a installation P P ( �' drain water tempering valve (DT� and approved backflow prevention assembly instructions inside must be installed. Most state and local plumbing codes prohibit water above P 9 0 0 150 F being discharged into the sanitary sewer. Water above 150 F will 9 9 rY weaken or deform PVC Schedule 40 pipe, poly drainage fixtures like interceptors and erode the coating of cast iron (leading to eventual failure). � O iTi lid 1 �i1� III - - •V row •' ■ I drain. See drawing for guidance. For detailed guidance on indirect connections, go to: webtools.schierproducts.comlrechnica I_Data/IndirecLCon nectio ns.pdf Hydrostatic Slabs (or Pressure Slabs) When installed under a hydrostatic slab (slab designed to withstand upward lift, usually caused by hydrostatic pressure) interceptor must be enclosed in a watertight concrete vault. page 2 of 10 concrete slab subject to hydrostatic pressure ODOR ALERT! Do not install air gap on outlet side of interceptor. High Water Table Installations Interceptors and risers are not designed to max water table height for withstand water table height in excess of the direct burial top of the unit when buried (see figure). If it is possible for this to occur, install the interceptor and risers in a water -tight concrete vault or f �I backfill with concrete or Plowable fill (wet Interceptor concrete and flowable backfill should be poured in stages to avoid crushing P 9 9 the Fully Support Base of Unit Install unit on solid, level surface in contact with the entire footprint of unit base; for suspended installations design PP trapeze to support the wet weight of the P 9 unit. Do not partially support unit or suspend unit using metal U-channel to create a trapeze. r concrete floor interceptor). At risk areas include but are not limited to tidal surge areas, floodplains and areas that receive storm water. Great Basin- models that are direct buried in high water table scenarios must be installed with an anchor kit. Models GB-50, GB-75, and GB-250 use model AK1 anchor kit Support Inlet and Outlet Piping Model GB-500 uses model AK2 anchor kit for use with deadmen anchors. Models GB-1000, GGI-750 and GGI-1500 use model AK3 anchor kit for use with deadmen For above grade installations ensure heavy anchors. inlet and outlet piping (such as cast iron or long runs) is properly supported or suspended during the entire installation process to prevent connection failure or damage to Flush -to -Grade Burials bulkhead fittings. Flush -to -Grade buried installations (without a riser) are not recommended for heavy foot traffic areas without the use of an internal gusset support kit SGK2 (for GB2) or SGK3 (for GB3). Schier I GB-2 Installation Guide I page 3 of 10 Interce for u P m suspended installation DO NOT COMPACT BACKFILL Interceptor pipe supports Schier I GB-2 Installation Guide 1. Cover 2. Standard Installation Flow Control Cartridge 3. 35 GPM Flow Control Extension (>5' below kitchen only) 4. 50 GPM Flow Control Extension (>5' below kitchen only) 5. Inlet Diffuser (Top) 6. Diffuser Retaining Nuts (x2) page 4 of 10 4 4 IIIL27 7. 4" Cleanout Plugs (x2) 8. Optional Side Outlets 4" FPT (x2) 9. Connection Fitting Gaskets (x4) 10. Bulkhead Connection Retaining Nuts (x4) 11. Inlet 4" FPT Connection 12. 3" Plain End Fittings (x2) 13. 4" Plain End Fittings (x2) 14. Diffuser Foot Retaining Nuts (x2) 15. Inlet Diffuser (Foot) 16. Cover Bolts (x4) 17. Cover Gasket 18. Air Relief/Visual Access 19. Outlet 4" FPT Connection 20. Outlet Diffuser (Top) 21. Outlet Diffuser (Foot) Schier I G13-2 Installation Guide 9031 21 ST AVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: SPEC SHEET REVISIONS: 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# F BACKFLOW PREVENTER - SPEC SHEET G TRAP PRIMER - SPEC SHEET H TEMPERING MIXING VALVE - SPEC SHEET ES-009 For 11 11 / - ACORN Job Name Contractor P! CON RO L STM Job Location Approval • • M 0d e l ST • 0 Engineer Contractor's P.O. No. - Lead -Free Lavatory Tempering Valve Approval Representative With Integral Mounting Feet APPLICATION: The Acorn ST70 is an ASSE 1070 certified, lead-free 0 0 Series009 thermostatic tempering valve that protects against Product Features dangerously hot water in any commercial sink or Reduced Pressure Zone lavatory application. This valve can be used with any ® a c a Assemblies No adjustment or air pre -charge required. type of faucet for maximum flexibility and can • Includes removable #60 mesh stainless steel conical filter screen. accommodate a single lavatory or up to 8 hand 0 0a • Four view holes for easy inspection after installation washing stations having a 0.5 gpm flow rate. Sizes: 1/a" - 2" � � .. _;,.T • Delivers potable water to seldom used floor drains Series 009 Reduced Pressure Zone Assemblies are designed • Pressure drop of 3 PSIG 20 K a required to activate the priming valve ST70-38 ST70-12 to protect potable water supplies in accordance with national 009QT-S P ( P) q P 9 plumbing codes and water authority requirements. This series Must be installed on cold fresh water lines of 1-1/2" diameter or less is designed to protect drinking water supplies from dangerous Y t • Operating range is 20 to 80 PSIG (138 to 552 Kpa) Patent #9,989,017 cross -connections in accordance with national plumbing codes • PFTP2500 primes up to 3 floor drains. and water authority requirements for non -potable service appli- - FEATURES' SPECIFICATIONS: cations such as irrigation, fireline, or industrial processing. PFTP3500 primes up to 10 floor drains. Machined of corrosion resistant lead free brass. • 4 Lead -Free certified DZR brass body with Valve Specifications: This series features two in -line, independent check valves, cap- o' ( ) corrosion resistant and lead free internal tured springs and replaceable check seats with an intermediate • PROFLO p Contains no springs or diaphragms. components. Maximum Operating Pressure: ................. 125 PSI (861 kPa) relief valve. Its compact modular design facilitates easy main- • Metered amount of water from the floor drain trap primer is distributed to as many as B MADE IN USA A Flow Rate 45 psi 310 k a differential: tenance and assembly access. Sizes'/4" - 1" shutoffs have tee • Valve body available in rough brass or rough @ P ( P ) handles. 009M2QT ten (10) floor drain traps by means of the patented distribution units. chrome plated. ST70-12:................................................. 4.5 GPM (17 LPM) Distribution units are fully guaranteed on a money back basis when installed per • Integral and cartridge -style checks with accessible Test Cock No. 3 � ST70-38: 4.0 GPM (15 LPM) Features screens to reventbackflowand tofilterdebris from """"""""""""""""""""""""' Test Cock No. 4 manufacturers' recommendations. P • Single access cover and modular check construction Ball Type • Can be connected to any cold water line, and will be automatically activated when a entering the valve. Certified Minimum Flow Rate*: .............. 0.25 GPM (1.0 LPM) for ease of maintenance Test Cocks • Temperature adjustment is made using an Allen Maximum Hot Water Temp: .............................. 180°F (82°C) valve or faucet that is on the line is opened. A pressure drop of 3 p.s.i. will activate all wrench. A locknut on the bonnet prevents • Top entry - all internals immediately accessible Test Cock p ** 5°F 3°C No.2 of the trap seal primers. unauthorized or accidental temperature Minimum Hot Water Supply Temp**: .................... ( ) • Captured springs for safe maintenance 0 • Can be disassembled in the field and permits filter replacement without affecting the adjustment. Above Set Point • Internal relief valve for reduced installation clearances Second Temperature Range*: 85°F-115°F 29°C-46°C First Check Check performance of the primer. • Commercial quality paraffin actuator provides P ..................••• ( ) • Replaceable seats for economical repair Module Module • The "0" ring seals are tested for reliability at a temperature range of -40 degrees to repeatable, reliable performance. Connections .......................... 1/2" NPT or 3/8" Compression • Bronze body construction for durability 1/4" - 2" Assembly Assembly II I I I 450 degrees F. 1 • Factory set to 105°F (41 °C) and field adjustable. ST70-12 • Ball valve test cocks - screwdriver slotted 1/4" - 2" • Large body passages provides low pressure drop Model • Drains Dist. 1 `-'V • Integral mounting Feet PRDESSU ROPRE PSID (kPa) CV 5 (34) 10 (69) 15 (103) 20 30 (138) (207) 45 (310) so (414) • Compact, space saving design R.P. Zone • No special tools required for servicing Relief Valve Assembly water Outlet PFTP2500 3 PFTPDUU FLOW RATE GPM (LPM) 0 7 1.5 (5.7) 2.1 (8) 2.6 (9.8) 3 3.7 (11.4) (14) 4.5 (17) 5.2 (19.7) PFTP3500 10 PFTPDUU Snr�rifiratinnc E _I I * In accordance with ASSE 1070 as certified by IAPMO ST70-38 A Reduced Pressure Zone Assembly shall be installed at each NOW Available potential health hazard location to prevent backflow due to WattsBox Insulated Enclosures. MODEL NO backsiphonage and/or backpressure. The assembly shall For more information, send for literature ES-WB. consist of an internal pressure differential relief valve located in a zone between two positive seating check modules with METTIERE PFTP250 captured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. Inquire with governing authorities for local installation requirements There shall be no threads or screws in the waterway exposed PFTP350, to line fluids. Service of all internal components shall be through ** Under Normal Operating Conditions PRESSURE 5 10 15 20 30 45 60 D O The wetted surface of these valves contacted by PSIDo (kPa) cv (34) (1 (103) (138) (207) (310) (414) consumable water contains less than 0.25% of lead FLOW RATE GPM (LPM) 0 6 1.3 (5) 1.9 (7.1) 2.3 (8.7) 2.7 (10) 3.3 (12A) 4 (15) 4.6 (17.5) by weight in conformance with national lead free law. rr I 11-2500 GUIDE SPEGIFIGATIDN: The lavatory tempering valve shall be IAPMO lab certified perASSE 1070 at 0.25 GPM (1.0 LPM) and CSAstandards and shall have a solid brass body with corrosion resistant internal components. It shall include integral checks with screens to prevent backflow and a single access bronze cover secured with stainless steel bolts. 1111111IMiM1111111 to filter debris from entering the valve. Temperature adjustment shall be made using an alien wrench and a locknut on the bonnet to The assembly shall also include two resilient seated isolation The information contained herein is not intended to replace the prevent unauthorized or accidental temperature adjustment. Valve shall provide 4.0 GPM (15 LPM) with 3/8" compression Warran and Codes connection and 4.5 GPM (17 LPM) capacity with the 1/2" NPT connection at 45 psi (310 kPa) differential. Temperature range shall be valves, four resilient seated test cocks and an air gap drain fit- full product installation and safety information available or the `7 85°F-115° F (29°C-46° C). Valve shall beAcorn model ST70. ting. The assembly shall meet the requirements of: USC; ASSE experience of a trained product installer. You are required to This PROFLO product carries a 1-year limited warranty. Std. 1013; AWWA Std. C511-92; CSA B64.4. Shall be a Watts thoroughly read all installation instructions and product safety Series 009. information before beginning the installation of this product. Acorn idorsu Controls data. Copyright Controls , � COMPANY Noe Ci of Indust , CA, Division ofAcom En ineerin NSF/ANSI 61 tY ry r g U P Certified %P.O. BOX 3527 tDoes not indicate approval status. Refer to Page 2 for Company, a member of Morris Group International. C City of Industry, CA approved sizes 8r models. Please visit www.acorneng.com ormost current 91744, U.S.A. 8 specifications. C O Est.'954 Phone 800-488-8999 lead-free ACORN ENGINEERING COMPANY 626-336-4561 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, Distributed Exclusive) b Fer uson and Wolsele Canada 1-833-334-9929 Submittal #Sn0 ASSE 1070 14-1�tururgF Engineered Pr,duunINWATM Y Y g y CSA B125.3 Fax 626-961-2200 please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- � 7968 01118 Revised: 05/30/19 Member of Morris Group InternationalT*' www.acomeng.com out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. 0 2018 Ferguson Enterprises, Inc. All Rights Reserved I URINAL - SPEC SHEET J THERMOSTATIC - SPEC SHEET Accu M ix 11 TM Speclflcatlons KOHLER, Thermostatic Heater Ideal for Sensor or Metering Faucets - UPC 407.3 Compliant Flectric Tankless Water Heater BARDONTM 1/8th ' : ' 1/8th ' Applications Features HIGH EFFICIENCY URINAL (HEU) Technical Information Installation Notes • Handwashing K 4904 E� •Lavatory sinks . Vitreous china • Washout • 3/4" top spud • 14" (356 mm) extended rim ADA • 0. 125 gpf (0.471pf) to 1.0 gpf (3.8 Ipf) °ers EPA G•r• • WaterSense® compliant when used with WaterSense WIN ST flushometer • Will replace K-4960-ET urinal Codes/Standards Applicable Specified model meets or exceeds the following: • ADA ai� A B C D E NUMBER OF (INCH) (INCH) (INCH) (INCH) (INCH) DRAINS SERVED 0 4 1/8" 3 1/4" 7/8" 1 1/4" 1 1/8" 3 (105) (82) (22) (32) (29) 0 4 1/8" 3 1/4" 7/8" 1 1/4" 1 1/8" 10 (105) (82) (22) (32) (29) Fixture: Configuration 3/4" top spud urinal Water per flush 0.125 gpf (0.47 Ipf) to 1.0 gpf (3.8 Ipf)* Spud inlet size 3/4" * Designed to flush with 0.125 gpf (0.47 Ipf) to 1.0 gpf (3.8 Ipf) of water when installed with a water -saving flushometer. Included components: 3/4" inlet spud 18376 2" outlet spud 18766 Strainer 85061 Hanger (2 required) 64512 Install this product according to the installation guide. • Kitchen/bar/utility sinks Refer to manufacturer's instructions and local codes for • Ideal for sensor or metering faucets flushometer requirements.° Performance Features Will comply with ADA when installed per Section 605 Urinals of the ADA 2010 Standards for Accessible Design. • Integrated mixing valve meets ASSE 1070 E • Unit meets UPC 407.3 requirements when properly installed • Self -diagnostics with intelligent controls actively protect heater in installed environment • SafeStartTM technology engages upon start-up to help avoid dry -fire occurrence • Low activation with 0.3 GPM turn on flow • Digital LED display communicates system status and heater operation feedback • Silent operation on all models except for AM012240T U Sf �O .. ,-Ir r;" Auem6led _- C ®� OS NSFaNSI7s C • US MH49688 I BIM • Mounts in any orientation for a flexible installation LISTIM In USA • ICC/ANSI A117.1 • Compact size fits almost anywhere; suitable for ADA compliant Note: Mounting location must be located within 2 feet of fixture. Over 2 feet, contact manufacturer. • ASMEA112.19.2/CSA B45.1 facilities / Only one input line, hot or cold, needed for an easy installation . EPA WaterSense o Designed to deliver hot water to a single pipe faucet or Suggested Specification mixing faucets Tankless water heater shall be an Eemax Accumix II model • Integral 3/8" compression fittings; no soldering or sweat number AM connections required Unit shall have ABS-UL 94-5VA rated cover. Unit shall have 0.3 • No T&P relief valve needed (check local codes); Ready to go, GPM turn on. Unit shall allow mounting in any direction. Uses right out -of -the -box ASSE 1070 approved integrated mixing valve to conform to Colors/Finishes *Urinal complies with ADA requirements when rim is • Save water and time by installing unit at the point -of -use UPC 407.3. Element shall be replaceable cartridge insert. Unit • 0: White mounted no higher than 17" (432 mm) from finished floor. • Control system activates heater only on demand shall have replaceable filter in the inlet connector. Element shall • Other: Refer to Price Book for additional colors/finishes • High temperature limit switch enables safe operation be iron free, Nickel Chrome material. Tankless water heater to • Active energy management with power modulation allows for utilize complex algorithm, actively managing power application Accessories 311 thermostatic accuracy ( ) 76 mm 18" (457 mm • CP: Polished Chrome Wall • 5-year limited warranty on leaks, 1-year on parts to real time system demand. Integrated flow meter, along with 3/4" Spud 12" (305 mm) Hangers inlet and outlet temperature sensors provide data which allows Specified Model 2, Product Specifications the unit to instantly adapt to variations in input parameters. Heater shall be fitted with 3/8" compression fittings to eliminate Model Description Colors/Finishes K-4904-ET High Efficiency Urinal (HEU) with 3/4" top spud ❑ 0 ❑ Other Recommended Accessories K-10668 WAVE DC flushometer - 0.125 gpf (0.47 Ipf) ❑ CP K-10949 Touchless DC urinal flushometer with TriPointTM technology - 0.125 gpf (0.47 Ipf) ❑ CP K-13520 Manual washdown urinal flushometer - 0.125 gpf (0.47 Ipf) ❑ CP K-10675 WAVE DC flushometer - 0.5 gpf (1.9 Ipf) ❑ CP K-10958 Touchless DC urinal flushometer with TriPoint technology - 0.5 gpf (1.9 Ipf) ❑ CP K-13519 Manual washdown urinal flushometer - 0.5 gpf (1.9 Ipf) ❑ CP K-10676 WAVE DC flushometer - 1.0 gpf (3.8 Ipf) ❑ CP K-10960 Touchless DC flushometer with TriPoint technology - 1.0 gpf (3.8 Ipf) ❑ CP K-13518 Manual washdown urinal flushometer - 1.0 gpf (3.8 Ipf) ❑ CP 14-1/8" I Dimensions: 13.75" H x 5.25" W x 4" D need for soldering. Maximum operating pressure of 150 PSI. (359 mm) � Weight 6 lb Diagnostic features to include error/fault display. Hot water 19" I Cover: ABS-UL 94-5VA storage tanks prohibited. Unit shall be Eemax or approved 2" NPT 483 mm 26-7/8" Color: White equal. Tap (683 mm) Temperature: Factory set to 105°F Min. Dynamic Operating Pressure: 35 PSI - 1(76 - 40-1/2' Max. Dynamic Operating Pressure: 150 PSI 3" (1029 mm) Element: Replaceable nlchrome cartridge insert mm) To Floor Fittings: 3/8" compression fttings 21 1 241 UL listed file number: E86887 (533 mm) 610 mm 2 NPT Tap - U.S. Patent Pending Technology Special Design Service 1 /4" 11 Inquiries for units for unique applications are welcome. (6 mm) � 6" (152 mm) Call our Technical Service department at 1-800-543-6163. Product Specification Outlet Detail The washout urinal shall be made of vitreous china with a 3/4" top spud. Urinal shall have a 14" (356 mm) extended rim. Urinal shall use 0.125 gpf (0.47 Ipf) to 1.0 gpf (3.8 Ipf) depending on flushometer specified. Urinal shall be WaterSense compliant when used with WaterSense flushometer. Urinal shall be Kohler Model K-4904-ET- Product Diagram BARDONTM 1/8th GPF HIGH EFFICIENCY URINAL (HEU) THE BOLD LOOK Page 1 of 2 USA/Canada: 1-800-4KOHLER Page 2 of 2 OICKOHLER 1116031-4-F (1-800-456-4537) 1116031-4-F formation and product specifications cordalned In this document arc suo'lect to change wi iout notice. REV 2019-02 www.kohler.com OFAI'ff D E S I G N S T U D 1 Q 9031 21 STAVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: SPEC SHEET REVISIONS: ZI 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET# P7 OFAI D E S I G N S T U D 1 0 2018 IFGC : CHAPTER 4 - TABLE 402.4 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE Gas Natural Inlet Pressure I Ow 2 psi Pressure Drop 0.5 In. w.c. peci is GravRF 0,60 PIPE SIZE linch) Nominal V2 314 1 1-114 1 1-tt2 2 2-112 1 3 4 5 6 8 1D 12 Actual ID 0.622 0.824 1.0491 1.3W0 1 1.610 1 2-067 1 2.469 1 3.068 1 4.026 1 5_047 1 6-065 1 7.981 1 10.020 1 11938 Length (h) Capacity In Cubic Feet of Gas Per Hour III _ 360 6ili 139f1 2.090 4.(i'_n (.4�Irl 113(1) 23.P► l 4J.4ir� (►?.i.l►I► 139,(11ii) 2520U1► 399.00ti 20 11h 247 40 `i:- 14111 _','r,11 4.41'11 7.7W 15.90t) 28.7(►U 46.51x) 95,5(x1 173.UU1) 1 5.1)(..N) 30 95 199 3 --r I _ i 11 ' 110 ; . , 111 + ? 50 12.70U 23 .IXx) 3 730(1 76,700 139.(?lH ► "(i.U(K) lU !+ 0 _ 2i I r.=- 9S5 1.1" _70211 5 35 10.905 19.7(0) :1.91110 65.600 119.000 15y.00_1 ;;U -' 151 2" 5tk3 873 1.68(1 2.6XU 4,740 9,66U 17.300 29.30() 5X2(I(i 106.0UU 167.OU1.1 60 (15 137 25? 52X 791 1.520 2,430 4,29U 4,760 15.") 25.600 52,7ai 1I5.7(K) 152,000 70 110 126 237 486 728 1.400 2.230 3.950 8,050 14,600 23.6(11► 4X,500 K8.100 139.000 80 56 117 220 45~ 677 1.300 2,091.) 3.67(1 7.490 13,6a), 22.000 45.100 S1.901 130.000 90 5_ 110 2r17 424 6115 1,"(1 1.950 3.450 7,03() 1_1.711t1 20.60(► I 4_.3(Ki 76.9(K1 1' .U(xI 100 0 104 19s 400 600 1.160 1,940 3 260 61640 12.000 l9 1W 40.Ua► T2,W) 115.000 ! 25 44 92 173 355 532 1.020 1,630 2,890 5.891) 10.600 17-5200 35,40fI 643(() 102.001, ! 0 40 83 15? 322 492 9-81,480 2.610 5,3 tl y.h= 15.601► i2.IcxI 5li30(► y_',3ai 175 i7 77 144 296 443 954 1.360 2.410 4,910 14.xho I4.4(m 53.w) !wyoo 200 34 71 134 175 I' -.4 1.'_70 —140 4,501 0260 13.41c► ' .Saa 49,9(Ki 79.o­ 250 30 6-1 119 244 366 704 1.120 1.980 4,050 7,320 11.900 24,300 44-200 70,(I(xI 300 27 57 I UK 221 331 638 1,020 1 AW 3.670 6,630 10,700 22A (X I 40.1(K) 63.401 -1U 25 53 99 '_03 05 51:7 911 1.650 .3,37t1 n_1W 9,SSl) 2[1,3ai 36,90(► SX,4IX1 400 49 92 IK9 293 54n 9711 ! 540 3,140 5,6![U 9,190 18.110 14,3U(1 54,3011 450 _ ' 46 K6 1 ?7 266 512 1(16 1 A40 2.941) 5330 1 9.620 17', n _ .?(Ka 50.900 SW _' ! 43 K2 1b8 ?5 ! 41i4 ' - , l 360 2 'Tso 5.030 N.I50 16.7a1 30.4(X) 48.1 (xi 55O _0 41 7X 159 -39 45'+ _ 171 C1 2.6-3(I 4,780 7,740 15.9(xI 28,9(K) 45,700 6t, 19 74 152 118 438 6101 1 140 2,520 4,560 7.380 15.200 27 50(► 43.600 650 I x 38 71 145 21 X 420 r,69 1,180 2.410 4,360 7,070 14 Sa 1 26,400 41,8041 700 17 6X 140 1 209 40. ( _ 1.140 2 120 1 4.19() 1 6.790 1 14.11.01 1 25300 40.100 750 17 35 66 135 202 381i 619 1,090 2.23U 4,040 6,540 13.41 '� 24,4W 38,6IX1 Qo 16 34 63 130 195 375 598 1060 2,160 3,900 6.31-0 13,0(Xi ' ,6(() 37,300 850 16 61 126 189 363 579 1,020 2 090 3.780 6,13) 12.6(XI 22.800 36,100 900 I 32 1 59 122 183 352 561 992 2,02() 3.660 5.930 12.2a1 " 1(() 35,000 950 15 31 58 IN 17X 2 545 963 1.9&1 3350 5,764) I IXXI 21.5(KI 34,0(Xi 1.000 14 30 56 115 173 333 53U 937 1.910 3.460 5,601) 11.5U0 20.9(X) 33,100 1,100 ; 4 28 53 109 164 316 501 1 8% 1.810 3 280 5.3_4) 10,9U0 19.9W 31.41HI I?IXI ! 27 51 104 156 301 4h11 R49 1,730 3.130 5,070 10.40(i IX.9(l(i -0,OIXi ;(A I I 26 41+ 100 150 289 41,11 913 1,6M) 3,000 4,X61) 79X(1 I X.10 i 28,701 i 1, 1)fl : , , 4- 06 144 27- 44_ 7 1 139(1 1,880 4,67U 9.590 I?.4U(� ? ,601i I SUIT l I '71_4 4; +3 139 _26- 426 752 1530 I 2.780 4 500 9._140 16.800 26.6IXI 1.600 1 1 23 4 X9 134 258 411 727 IAKO 2.680 4.34t) 8.920 (6 2(X) 25.6IX1 I_7U0 ! 1 22 42 K(I 130 250 398 703 1,430 _.5%) 4,2U() 9.630 15.7W .24.N00 I,K011 2_' 4: W 126 242 386 61,42 1.390 ' ;20 4,070 K370 15-211(1 24,100 1.9011 to 21 4n Ni I _2 1 2-15 75 662 1,350 _.44U _ .96t) X.1. 0 I ,Sao 2 .4U1I 2,0011 NA _10 3y 79 1 1114 1 2_19 364 644 1310 2,380 3.8% 7.910 14AW 22iIX1 For SI: I inch = 25.4 mm. I toot = 304.8 mm. I pound per squam inch = 6195 kPat, l-inch water column = 0?488 kl?u, 1 British thermal unit per hau = 0.2931 W, I cubic foot per hour = 0.0283 m'rh, I degree = 0.01745 rad. Notes: 1. NA mean a flow of ksc than IU Olt 2. Table entnes hm c been rounded to three significant digits. CUT-OFF VALVE CONTROL VALVE LONGEST LENGTH =28i-11 ii 2 BUNNER 52,000 BTU GRIDDLE 48 CF 90,000 BTU GYRO MACHINE 72,000 BTU DEEP FRYER 120,000 BTU ISOMETRIC GAS PIPING PLAN SCALE: N.T.S. GAS APPLIANCE SCHEDULE NO. QTY DESCRIPTION LOCATION EACH BTU INPUT (MBH) TOTAL BTU INPUT (MBH) APPLIANCE INLET PRESSURE GAS PRESSURE REGULATOR APPLIANCE CONNECTION SIZE 1 1 2 BURNER KITCHEN 52,000 52,000 7 IN. W.C. MAXITROL 325-5L 3/4" 2 1 DEEP FRYER KITCHEN 120,000 120,000 7 IN. W.C. MAXITROL 325-5L 3/4" 3 1 GRIDDLE KITCHEN 90,000 90,000 7 IN. W.C. MAXITROL 325-5L 3/4" 4 1 GYRO MACHINE KITCHEN 72,000 72,000 7 IN. W.C. MAXITROL 325-5L 3/4" TOTAL 334000 N GAS PIPING PLAN SCALE : aia° = 1-a° 9031 21 STAVE SW SEATTLE, WA 98106 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL: INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM RESUB May 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT TITLE: GYRO MAKERS 10016 EDMONDS WAY # A, EDMONDS, WA 98020 SHEET TITLE: GAS PIPING PLAN REVISIONS: zi 05.29.2024 CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 05/29/2024 SHEET#