Loading...
APPROVED PLN BLD2023-0511+Building_or_Construction_Plan+4.25.2023_7.32.02_AM+3502776B i�-4 ALL a &t .INS P CODE AF Mobil ityPON EXISTING 25'-7" STEALTH CUPOLA AT&T SITE NAME: HARRISON AT&T FA NUMBER: 10037166 AT&T SITE ID: WA6272 RFDS NAME / REVISION: WASNU2605 / 2.02 / 10/15121 ADDRESS: 9617 FIRDALE AVE EDMONDS, WA 98020 COUNTY: SNOHOMISH JURISDICTION: CITY OF EDMONDS TAXLOT NUMBER: 00449900000100 ZONING DESIGNATION: FVMU OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: II-B A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: FIRDALE ASSOCIATES LLC 9617 FIRDALE AVE EDMONDS, WA 98115 LATITUDE / LONGITUDE: N 47.7782222' (NAD83) W-122.3618639° GROUND ELEVATION: ±422' AMSL PACE #1: MRWOR052781 PACE #2: MRWOR052569 PACE #3: MRWOR052583 PTN #1: 3801AOYG34 PTN #2: 3801AOYF4A PTN #3: 3801AOYFZ2 PROJECT SUMMARY 1 of UI K d Work H Address A = r oOn Owner M� =I= Approved Date n � o � Ia F Building Official oa Permit Number g� ~gym E�� maid V �e _o2 UU� 3 RKSUBJECTI FIELD HARRISON '.OMPLIANCE 2022 5G N R RADIO FA#: 10037166 / SITE ID: WA6272 PROVED OBTAIN ELECTRICAI 9617 FIRDALE AVE S MUST BE PERMIT FROM EDMONDS, WA 98020 JOB SITE STATE LABOR & INDUSTRIES SNOHOMISH COUNTY FROM SEATTLE-TACOMA INTERNA PORT EXPRESSWAY (0.8 MI). KEEP RIGHT FOR EXIT TO WA-518 E/1-5/1-405/SEATTLE/TACOMA AND MERGE ONTO WA-51BE (0.6 MI). MERGE ONTO WA-518 E (0.7 MI). TAKE THE EXIT ON THE LEFT ONTO I-5 N TOWARD SEATTLE (21.1 MI). TAKE EXIT 176 FOR NE 175TH ST TOWARD SHORELINE (0.7 MI). TURN LEFT ONTOP NE 175TH ST (0.8 MI). TURN RIGHT ONTO AURORA AVE N (1.0 MI). TURN LEFT ONTO N 195TH ST (0.7 MI). TURN RIGHT ONTO 3RD AVE NW (0.5 MI). CONTINUE STRAIGHT AHEAD INTO THE PARKING LOT, SITE WILL BE ON BEHIND THE BUILDING ON THE RIGHT (NORTH) SIDE OF ROAD. AT&T MOBILITY PROPOSES CHANGES TO THE EXISTING UNMANNED TELECOMMUNICATIONS FACILITY WITH THE GENERAL SCOPE OF WORK DESCRIBED BELOW: TOWER SCOPE OF WORK: • REMOVE ALL EXISTING MOUNTS • INSTALL (3) NOKIA AEQK ANTENNAS • INSTALL (6) KATHREIN 782 11288 DIPLEXERs • INSTALL (3) NEW MOUNTS W/MOUNT PIPES • INSTALL NEW FRP STEEPLE DESIGN BY TRYLON GROUND SCOPE OF WORK: • REMOVE (3) KAELUS DBC0135F3V92-1 DIPLEXERs • REMOVE EXISTING ARGUS DC POWER PLANT & CABINET • REMOVE (20) EXISTING 145AH BATTERY CELLS • INSTALL (1) DC12-48-60-0-25E OVP • INSTALL (1) ASIK & (1) ABIL IN EXISTING SUBRACK C2 • INSTALL (1) AMIA, (3) ABIA, & (1) ASIA IN EXISTING SUBRACK C1 • INSTALL NEW -48V VERTIV NETSURE 512 OUTDOOR DC POWER PLANT CABINET W/ (11) RECTIFIERS & (2) CONVERTERS. • REUSE EXISTING BATTERY CABINET & RECONFIGURE W/ (5) STRINGS OF 180AH BATTERIES (20 TOTAL BATTERIES) • PROPOSED (N) STEALTH CUPOLA AND MOUNTING FIXTURES (DESIGNED BY OTHERS) TO BE INSTALLED NOTE: THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CANGES IS TO BE PERFORMED BY OTHERS AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. AT&T IS SOLELY RESPONSIBLE FOR THE ELECTRICAL POWER DESIGN. PROJECT DESCRIPTION f Of Edmonds Building Department CELLULAR MODIFICATIONS 9617 FIRDALE AVE AT&T 05/01 /2 Eri,,Scv -'� BLD2023-0511 AERIAL ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. BUILDING CODE 2018 WASHINGTON STATE BUILDING CODE (2018 IBC) MECHANICAL CODE 2018 WASHINGTON STATE MECHANICAL CODE (2018 IMC) ELECTRICAL CODE 2020 NATIONAL ELECTRICAL CODE (2020 NFPA 70) FIRE CODE 2018 WASHINGTON STATE FIRE CODE (2018 IFC) ACCESSIBILITY REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2018 IBC BUILDING CODE. APPLICABLE CODES APPLICANT ZONING MANAGER AT&T MOBILITY THOMAS MCMULLIN 19801 SW 72 AVENUE, SUITE 200 THOMAS.MCMULLIN@MASTEC.COM TUALATIN, OR 97062 PHONE: 630-228-6229 (EXT. 426229) ADDRESS: 22263 68TH AVENUE SOUTH PROJECT MANAGER KENT, WA 98032 ROBERT LEIGHTON PHONE: 206-817-0733 ENGINEER COMPANY: MASTEC NETWORK SOLUTIONS GPD GROUP ADDRESS: 22263 68TH AVENUE SOUTH PROFESSIONAL CORPORATION KENT, WA 98032 520 SOUTH MAIN STREET, SUITE 2531 CONSTRUCTION MANAGER AKRON, OH 44311 CONSTRUCTION L TION MANAGER CONTACT: CHAD BURTON, 330-572-2100 MICHAM ICHAEL.SUTH ERBY@MASTEC.COM PHONE: 231-527-5269 PROJECT TEAM SITE SHEET NUMBER DESCRIPTION T-1 TITLE SHEET N-1 GENERAL NOTES N-2 ELECTRICAL NOTES C-1 OVERALL SITE PLAN C-2 COMPOUND PLAN C-3 EXISTING & PROPOSED EQUIPMENT PLANS C-4 EXISTING & PROPOSED TOWER ELEVATIONS C-5 EXISTING & PROPOSED ANTENNA PLANS C-6 EXISTING & PROPOSED EQUIPMENT SCHEDULES C-7 EQUIPMENT SPECIFICATIONS C-8 DC POWER PLANT SPECIFICATIONS G-1 GROUNDING SCHEMATIC G-2 GROUNDING DETAILS RF-1 RF PLUMBING DIAGRAM RF-2 RF PLUMBING DIAGRAM RF-3 RF PLUMBING DIAGRAM ATTACHMENTS S-1 FRP STEEPLE DESIGN (BY TRYLON) S-2 CONNECTION DETAILS (BY TRYLON) SHEETINDEX STRUCTURAL ANALYSIS BY: TRYLON DATED: 02/28/2023 MOUNT ANALYSIS BY: BY OTHERS DATED: PENDING ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 22"x34". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSION AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. REFERENCE DOCUMENTS ®CALL WASHINGTON ONE CALL CALL 3 WORKING DAYS BEFORE YOU DIG! AO GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH 311 330.572.2100 Fox 330.572.2101 iV �t 7i Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 w z w z W dw x 2 U U o oLU o O a O LL LL w wn w m w m UJ m � m o a ly a m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL o F— Z > o LLI O ILI w N -j a LU Q �o J 2 a)o - W i= ISSUED FOR: REVIEW 12/14/21 — TION L DESIGNER rMANAGER B MAS GPD JOB NO. 2021723.06.74953.01 T=1 SITE ACTIVITY REQUIREMENTS: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE THE CONSTRUCTION MANAGER. 2. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 3. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF AQUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 4. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON TOWER SITE" AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 5. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 6. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 9. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 10. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 11. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 12. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, , AND/OR LOCAL UTILITIES. 13. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 14. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 15. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 16. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 17. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 18. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 19. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 20. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 21. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GENERAL NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: AT&T MOBILITY TOWEROWNER: FIRDALE ASSOCIATES LLC 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF AT&T. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND AT&T PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF AT&T 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. /O GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH"311 330.572.2100 Fox 330.572.2101 IL WFMobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 w Z O w z K EL >w K U U o 00 0 O a O LL O LL w wn w m w m m � m o a IL Q m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL O F- Z >O 0 w N Q Z a� J a U) NQ Li LL Z 1.6 Q O 2 a)o W w Z W 0 ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 N-1 ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT, 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR AT&T BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T'. 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED"` NEG (-) BLACK`• SEE NEC 210.5(C)(1) AND (2) POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION PINK TEMPORARY SURVEY MARKINGS RED ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS ORACOMMUNICATION, ALARM OR SIGNAL LINES, NGE CABLES, OR CONDUIT AND TRAFFIC LOOPS - POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES - SEWERS AND DRAIN LINES GREENFIELD GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES-S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45" BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 210 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). /O GPD GROUP Professional Corporation 5205o h Main Sheet, Suite 2531 Akron, OH4 311 330.572.21 oo Fox 330.572.2101 m Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 ti Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w O w z K [L > W W 2 U o) o 0 o O a O LL LL W W W w � w Lu m w m m � m Lu o a W Q m U 0_ RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELECTRICAL SEAL U) LW r O O Z >o p a1. Z _ N j J a� Q �' o �U 2 aa)) �p LU U W J W ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD PROJECTMANAGER CB IMA:NER GPD JOB NO. 2021723.06.74953.01 N .2 APPROVED BY PLANNING May 02 2023 Pursuant to ECDC 20.50.80(G), antennas and equipment shall maintain the appearance intended by the original facility, including, but not limited to, color, screening, landscaping, camouflage, concealment techniques, mounting configuration, or architectural treatment. a Ik — (E) 15'-7" PEAKED ROOF HEIGHT u (E) WOOD FENCE OVERALL SITE PLAN SITE PLAN DISCLAIMER: t SCALE. 1"=20'-0" (FULL SIZE) Z PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED zo• 1a o zo• 1"�0•-0" (11x17) FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. GPD GROUP HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. AO GPD GROUP Professional Corporation 5205o h Main 5t:eet, Suite 2531 Akron, OH"311 330.572.2100 Fax 330.572.2101 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41asTec Network Solutions 2226368TH AVENUE SOUTH KENT, WA 98032 Z w Ct w z K EL>W W U U o OO o O a O LL O LL W W W W f/1 W m W m LU m � m LU \ o a W Q m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL I r 0i z a O a; W WQ H 0' UL z J Q �o Q 2 °' w W O ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 C-1 /Ak GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH4 311 330.572.2100 Fax 330.572.2101 APPARENT PROPERTY LINE (TYP) (E)WOOD FENCE Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 x (E) AT&T EQUIPMENT PAD I -SEE SHEET C-3 FOR DETAILED EQUIPMENT PLAN 1 41 a sTe c ® ® ®INetwork Solutions g 22263 68TH AVENUE SOUTH KENT, WA 98032 I I w C110 oo W w� I I o a o II11 owo I j ; LU a O I N 11 I I a s o I *W II11 I o 0 LL �J Z w I1 m w<mU LU (E) 38'-0' STEALTH CUPOLA I I I s w/AT&T ANTENNAS I % (E)DOUBLE /+ / ACCESS SS GATE J I RECEIVED Apr 25 2023 (E)UNDERGROUND /// /�// -I CITY OF EDMONDS CONDUIT PATH TO / r DEVELOPMENT SERVICES STEALTH CUPOLA DEPARTMENT (FIELD VERIFY) / / / / I TELECOM SEAL 0 0 0 0 z '> "go ----- Lm m I Q a a, Z / QLLZ O 0 (E) ON BUILDING PATH TO STEALTH CUPOLA / / / W (FIELD VERIFY) FENCED COMPOUND 'O COMPOUND PLAN t SCALE. ' 1/2"=1'-O'(FULL SIZE) Z 21' 0 2' 1/4'-0"(11.17) ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 C-2 C (E) WOOD FENCE (E) 4"0 CONDUIT (TYP.; (E) (3) NOKIA 4T4R BE 16OW AHCA RRF (E) FLEX16 CABINET I (E) FIBER SLACK BOX (E)GPS ANTENNA (E) 8' DOUBLE ACCESS GATE (E) W( (E) GE If (PI MAIN n■ 1 1 2 (E) HORIZONTAL CABLE TRAY (E) (3) KAELUS DBC0135F3V92.1 TO BE REMOVED (E) H-FRAME (TYP.) (E)(1)RAYCAP DC1248-80-0-25E SURGE SUPPRESSION DISTRIBUTION UNIT (E) ARGUS POWER CABINET W/ RECTIFIERS AND (4) 145AH BATTERY CELLS TO BE REMOVED (E) BATTERY CABINET W/ (16) 145AH BATTERY CELLS -BATTERIES TO BE REMOVED, CABINET TO REMAIN & BE REUSED (E) 6"0 CONDUIT (TYP.) (E) ICE BRIDGE (E) UMTS CABINET (E) TELCO CABINET 3 1 4 NOTE: THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CANGES IS TO BE PERFORMED BY OTHERS AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. AT&T IS SOLELY RESPONSIBLE FOR THE ELECTRICAL POWER DESIGN. (E) WOOD FENCE (E)4"0 CONDUIT (TYP.) (E) (3) NOKIA 4T4R BE 16OW AHCA RRH (E) FLEX16 CABINET (E) FIBER SLACK BOX (E) GPS ANTENNA (E) 8' DOUBLE ACCESS GATE (E) WC (E) GE IP IPl MAIN 5 INSTALLATION NOTES: 1. CONTRACTOR SHALL COMPLY WITH CLEARANCE SET BY AT&T STANDARDS. G n D G R O U P 2. 8" MINIMUM SIDE -TO -SIDE CLEARANCE FROM EXISTING & PROPOSED RRHs. Professional Corporation 3. 16" MINIMUM VERTICAL CLEARANCE FROM BOTTOM OF RRH TO TOP OF LOWER RRH, WHEN STACKED. 5205e h Me meet, sere 2531 Akron, OH 44311 330.572.2100 Fax 330.512.2101 EXISTING EQUIPMENT PLAN F �� PROPOSED EQUIPMENT PLAN t SCALE. 1/2"=1'-O'(FULL SIZE) L SCALE. 1--1'-D'(FULLSIZE) 2• 1' 0 2• 114"=1'-0"(11x17) Z 2' 1' 0 2' 114•=1'-0"(11.17) (E) HORIZONTAL CABLE TRAY IN) (1) RAYCAP DC12-48-60-0-25E SURGE SUPPRESSION DISTRIBUTION UNIT TO BEINSTALLED (E) H-FRAME (TYP.) (E) (1) RAYCAP DC1248-80-0-25E SURGE SUPPRESSION DISTRIBUTION UNIT IN)-48V VERTIV NETSURE 512 OUTDOOR DC POWER PLANT CABINET W/ (11) RECTIFIERS &(2)CONVERTERS (E) BATTERY CABINET TO BE REUSED & RECONFIGURED W/ (5) STRINGS OF 180AH BATTERIES (20 TOTAL BATTERIES) (E) 6"0 CONDUIT (TYP.) (E) ICE BRIDGE (E)UMTS CABINET (E) TELCO CABINET Mobility 19801 SW 72ND AVENUE, STE. 200 7UALATIN, OR 97062 41 a ISENetwo 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w O w z EL> W w U U o 00 0 O a O LL O 0 w W w w � w LU m w m m � m LU o a w Q m U 0_ RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL 0 �Lu� /A OQ z 0 ;o < a O d Na3 LU d~ zz o Q r O G = a) z a DJ Cy Lu Lu ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD DESIGNER r77� MSG GPD JOB NO. 2021723.06.74953.01 z C-3 1 C B (E) TOP OF CUPOLA ELEV. = 38'-0" AGL (E) BUILDING ROOF PEAK ELEV. = 25'-7" AGL (E) BUILDING ROOF PEAK ELEV. = 15'-7" AGL (E) PATIO ROOFTOP ELEV. = 12'-7" AGL (E) GRADE ELEV. = 0'-0" AGL (N) TOP OF CUPOLA ELEV. = 41'-0" AGL (E) BUILDING ROOF PEAK ELEV. = 25'-7" AGL 40 (E) BUILDING ROOF PEAK ELEV. 115'-7" AGL �(E) PATIO ROOFTOP ELEV. = 12'-7" AGL �(E) GRADEGRADE ELEV. =11%" AGL 2 3 (E) CUPOLA TO BE REMOVED (E) EQUIPMENT 54 REMAIN (3) ACE XXQLH-EQUIPMENT TO REMAIN ANTENNAS ,T (3) NOKIA 4T4R B12M4 320W AHLBA RRHS (3) NOKIA 4T4R B25/66 320W AHFIB RRHS (3) ALU RRH4X25-WCS4R RRHS 0 r (2) DC6 OVPs 16� (N) TOWER MOUNTED EQUIPMENT TO BE INSTALLED (3) NOKIA AEQK ANTENNAS (6) KATHREIN 782 11288 DIPLEXERS MOUNTING PIPES AND EXTENDED CUPOLA DESIGNED BY TRYLON, REFER TO STRUCTURAL SHEETS ATTACHED 1 EXISTING BUILDING ELEVATION �SCALE: N.T.S. (E) EQUIPMENT TO REMAIN (3) ACE XXQLH-654L8H6-IVT ANTENNAS (3) NOKIA 4T4R B12114 320W AHLBA RRHS (3) NOKIA 4-R B25/66 320W AHFIB RRHS (3) NOKIA 4T4R B5 160W AHCA RRHS (3) ALU RRH4X25-WCS4R RRHS (2) DC6 OVPS n PROPOSED BUILDING ELEVATION 2 SCALE: N.T.S. 4 (E) TIP OF ANTENNA ELEV. = 34'-1"AGL (E) AT&T ANTENNAs RAD L ELEV. = 31'-0" AGL ALL EXISTING AT&T FEEDLINES TO REMAIN (12)1-5/8" COAX (2) 3/8" FIBER (4) 3/4" DC CABLES (ROUTED ON EXISTING CABLE BRACKETS) (N) TOP OF HIGHEST APPURTENANCE ELEV. = 38'-9" AGL (N) AT&T ANTENNAS RAD(N )AT&T RAD 4� ELEV. = 37'-6" AGL (E) TIP OF ANTENNA ELEV. = 34'-1"AGL E AT&T ANTENNAS RAD 4 ELEV. = 31'-0" AGL ALL EXISTING AT&T FEEDLINES TO REMAIN (12)1-5/8" COAX (2) 3/8" FIBER (4) 3/4" DC CABLES (ROUTED ON EXISTING CABLE BRACKETS) AO GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH4 311 330.572.2100 Fax 330.572.2101 am Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 w Z O w z EL>W W U U o 00 0 O a O LL W O W LL W W m f/1 W W m m � m a o W Q m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL 0 N 'W V! Z 00 z ; 0 tea/ N ` N J Q / W Q LLz a _ a) ZZ_ W o r N 0 X H W ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 C-4 C FEM A 1 2 EXISTING RRH NOKIA 4T4R 312/14 320W AHLBA EXISTING ANTENNA (3 TOTAL, 1 PER SECTOR) ACE XXQLH-654LBH6-IVT (3 TOTAL, 1 PER SECTOR) ALPHA GAMMA O Al 60° 300" 00 C1 O (E) 38'-l" STEALTH CUPOLA TO BE REMOVED 0 O O EXISTING RRH ALU RRH4X25-WCS-4R EXISTING RRH (3 TOTAL, 1 PER SECTOR) NOKIA 4T4R B25/66 320W AHFIB (3 TOTAL, 1 PER SECTOR) 0000 \ EXISTING OVP RAYCAP DC6 (2 TOTAL) EXISTING CABLE ENTRY PORTS B1 BETA 200' EXISTING ANTENNA PLAN 1 SCALE: N.T.S. 3 4 E 1 EXISTING RRH NOKIA 4T4R B12/14 320W AHLBA EXISTING ANTENNA (3 TOTAL, 1 PER SECTOR) ACE XXQLH-654L8H6-IVT (3 TOTAL, 1 PER SECTOR) ALPHA GAMMA A6 60, 300` 0 0 C6 (N) 41'-0" STEALTH CUPOLA . AND MOUNTING FIXTURES 2 NEW DIPLEXERS TO BE INSTALLED (DESIGNED BY TRYLON, , ■■ KATHREIN 782 11288 REFER TO STRUCTURAL (6 TOTAL, 2 PER SECTOR) SHEETS ATTACHED) �♦ O O O EXISTING RRH O ALU RRH4X25-WCS-4R EXISTING RRH (3 TOTAL, 1 PER SECTOR) NOKIA 4T4R B25/66 320W AHFIB (3 TOTAL, 1 PER SECTOR) ■ 0000 AN EXISTING OVP RAYCAP DC6 (2 TOTAL) EXISTING CABLE ENTRY PORTS B6 BETA 200' PROPOSED ANTENNA PLAN 31'-0" RAD 2SCALE: N.T.S= . 0 z GENERAL NOTES: 1. CONTRACTOR SHALL FIELD VERIFY MOUNTING OF EXISTING & PROPOSED EQUIPMENT MEETS AT&T MINIMUM SPACING REQUIREMENTS AS DESCRIBED IN AT&T ANTENNA COLLOCATION GUIDELINES (ATT-002-290-105), GENERALLY SUMMARIZED BY: - T-0"MINIMUM DISTANCE REQUIRED BETWEEN LTE ANTENNAS ON SAME SECTOR. -6'-0" MINIMUM DISTANCE REQUIRED BETWEEN 70OBC & 700DE ANTENNAS ON SAME SECTOR. -4'-0" MINIMUM DISTANCE REQUIRED BETWEEN LTE 700 ANTENNAS ON OPPOSING SECTORS. -3'-0" MINIMUM DISTANCE REQUIRED BETWEEN 5G CBAND ANTENNAS AND OTHER TECHNOLOGIES. 2. CONSTRUCTION MANAGER/ GENERAL CONTRACTOR = SHALL REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR TO INSTALLATION. O Z 3. ANY REQUIRED MOUNT MODIFICATIONS DESIGN OR MOUNT REPLACEMENT SHALL BE APPROVED BY EOR. AND MOUNTING F (DESIGNED BY REFER TO STRI SHEETSAT GAMMA 300' B5 BETA 200' PROPOSED ANTENNA PLAN 37'-6" RAD 3 SCALE: N.T.S. ALPHA 60, NEW ANTENNA TO BE INSTALLED NOKIA AEQK (3 TOTAL, 1 PER SECTOR) AO GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH"311 330.572.2100 Fax 330.572.2101 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41 asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w 0 w z K O_ w w U c o 00 0 O a O w w w Lu m w m m � m Lu \ o a UJ Q m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL a W Oz aQ z''c" O p a1. J Nab aQ 06z ILL Z 0 Z T W LU � H/� Z cn Q X LU ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD DESIGNER r77� MSG GPD JOB NO. 2021723.06.74953.01 z C-50 EXISTING EQUIPMENT SCHEDULE (VERIFY WITH CURRENT RFDS) ALPHA ANTENNA RADIO DIPLEXER TMA SQUID CABLES POSITION TECH. STATUS/MANUFACTURER MODEL AZIMUTH CENTER TILT TILT QTY. STATUS/MODEL LOCATION QTY. STATUS LOCATION QTY. STATUS QTY. STATUS QTY. STATUS/TYPE SIZE LENGTH UMTS 850 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER 2 (E)FIBER 3/8" 200' LTE700 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER 4 (E) DC 3/4" ±200' A7 5G 850 (E) ACE XXQLH-654L8H6-IVT 60° 31.11. 0° 0°/2° 1 (E) KAELUS GROUND - - 2 (E) RAYCAP DC6 1 (E) NOKIA 4T4R B516OW AHCA GROUND LTE1900 DBC0135F3V92-1 LTE AWS 4 (E) COAX 1-5/8" 200' 1 (E)ALU RRH4X25-WCSAR TOWER LTE WCS BETA UMTS 850 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER LTE700 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER 61 5G 850 (E) ACE XXQLH-654L8H6-IVT 200° 31'-0" 00 00/2° 1 (E) KAELUS GROUND - - - - 4 (E) COAX 1-5I8" 200' 1 (E) NOKIA 4T4R B516OW AHCA GROUND LTE1900 DBC0135F3V92-1 LTE AWS 1 (E)ALU RRH4X25-WCSAR TOWER LTE WCS GAMMA UMTS 850 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER LTE700 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER C1 5G 850 (E)ACE XXQLH-654L8H6-IVT 300° 31'-0" 00 2° 1 (E)KAELUS GROUND - - - - 4 (E)COAX 1-5/81, 200' 1 (E) NOKIA 4T4R B516OW AHCA GROUND LTE1900 DBC0135F3V92-1 LTE AWS 1 (E)ALU RRH4X25-WCSAR TOWER LTE WCS FINAL EQUIPMENT SCHEDULE (VERIFY WITH CURRENT RFDS) ALPHA ANTENNA RADIO DIPLEXER TMA SQUID CABLES POSITION TECH. STATUS/MANUFACTURER MODEL AZIMUTH CENTER TILT TILT QTY. STATUS/MODEL LOCATION QTY. STATUS LOCATION QTY. STATUS QTY. STATUS QTY. STATUS/TYPE SIZE LENGTH AS 5G CBAND (N) NOKIA AEQK 60° 37'-6" 0° 00 - - - - - - - - - - - - - - LTE 700 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER 2 (E) FIBER 3/8" 3200' 5G 850 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER 4 (E) DC 3/4" 200' LTE1900 (N) KATHREIN 782 A6 LTE AWS (E)ACE XXQLH-654L8H6-IVT 60° 31'-0" 0° 0°/2° 2 11288 TOWER - - 2 (E) RAYCAP DC6 1 (E) NOKIA 4T4R B5 160W AHCA GROUND 5G 1900 4 (E) COAX 1-5/8" 200' 1 (E)ALU RRH4X25-WCS-4R TOWER LTE WCS BETA B5 5G CBAND (N) NOKIA AEQK 200° 37'-6" 0° 0° - - - - - - - - - - - - - - LTE 700 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER 5G 850 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER LTE1900 (N)KATHREIN 782 B6 LTE AWS (E)ACE XXQLH-654L8H6-IVT 200° 31'-0" 0° 0°/2° 2 11288 TOWER - - - - 4 (E)COAX 1-5/8" 200' 1 (E) NOKIA 4T4R B5160W AHCA GROUND 5G 1900 1 (E)ALU RRH4X25-WCS-4R TOWER LTE WCS GAMMA C5 5G CBAND (N) NOKIA AEQK 300° 37'-6" 0° 0° - - - - - - - - - - - - - - LTE 700 1 (E) NOKIA 4T4R B12/14 320W AHLBA TOWER 5G 850 1 (E) NOKIA 4T4R B25/66 320W AHFIB TOWER LTE1900 (N)KATHREIN 782 C6 LTE AWS (E)ACE XXQLH-654L8H6-IVT 300° 31'1" 0° 0°/2° 2 11288 TOWER - - - - 4 (E)COAX 1-518" 200' 1 (E) NOKIA 4T4R B5 160W AHCA GROUND 5G 1900 1 (E)ALU RRH4X25-WCS-4R TOWER LTE WCS /Ak GPD GROUP Professional Corporation 5205o h Main StteIt, 5uite2531 Akron, OH"311 330.572.2100 Fax 330.572.2101 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41 asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w O w z iL>W W U U o 00 0 O a O LL O LL W W W W f/1 W m W m Lu m � m Lu \ o a W Q m U D_ RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL Z >o ~ LU ZJ paw w Q W Li W Q LL Z r O T /x y °' w W U) ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD PR-E--AGER DESIGNER CB MAS:j GPD JOB NO. 2021723.06.74953.01 C-6 THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. NOKIA - AEQK WEIGHT (WITHOUT MOUNTING HARDWARE): 99.2 LBS SIZE (HxWxD): 29.5x17.7x9.5 IN. MOUNTING HARDWARE: MANUF. SUPPLIED PIPE MOUNT HARDWARE 1 NOKIA - AEQK t SCALE: NOT TO SCALE MOUNTING BRACKET (SUPPLIED W/ ANTENNA) ANTENNA MOUNTING PIPE INSTALLER OTE: 1. �PEN%%.KETS, AND MISCELLANEOUS BE GALVANIZED UNLESS NOTED 5 ANTENNA MOUNTING DETAIL SCALE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. NEW ANTENNA 2ACKET 'ANTENNA) i Itl Its KATHREIN - 782 11288 WEIGHT (WITHOUT MOUNTING HARDWARE): 11.02 LBS SIZE (HxWxD): 6.02x6.714.52 IN. 2 KATHREIN - 782 11320 SCALE: NOT TO SCALE DETAIL NOT USED 3 SCALE: NOT TO SCALE DETAIL NOT USED I DETAIL NOT USED 6 SCALE: NOT TO SCALE 7 SCALE: NOT TO SCALE DETAIL NOT USED 4 SCALE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. .. 0X , X N �I RAYCAP - DC12-48-60-0-25E WEIGHT: 56.3 LBS SIZE (LxWxD): 18.17x20.064.37 IN. OPERATING TEMPERATURE: -40° C TO +100* C NOMINAL OPERATING DC VOLTAGE: 48V DC VOLTAGE PROTECTION RATING (VRP): 700V ENCLOSURE TYPE: OUTDOOR -NEMA4 RATED C�RRAYCAP - DC12 48-60-0-25E SCALNOT TO SCALE /O GPD GROUP Professional Corporation 5205o hMain Stteet, 5-' 2531 Akron, OH4 311 330.572.2100 Fax 330.572.2101 m Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 %%M a sTe c Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w O w z EL W W 2 U O a O LL LL W W W w � w Lu m w m m � m Lu \ o a Iy Q m U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL v! Z C` >o 1.Q Z r O Z O W LU Q LL z aU LL 2 Wo au LULU W ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD PR.E--,IGER DESIGNER CB MAS GPD JOB NO. 2021723.06.74953.01 C-7 2i w 21 (O A () q� �oeD 0 0 00 I I AC OSP UIr'IV Cables Rear View 25.6 ;Rap Mwrll A A LED LD's^1" nu.lann s♦dcn GFC omw ECI 'ad [ollaai IEOwnW amn,: 251 O�nmgl I IS RU Redd MTERNAL VIEW OF ROAt-IWNO WALL el 1 .B." Clemam Left Side View A r-�-- A FRONT VIEW ➢OoRS RE1AaVEDI LED urim Singe S.-V era slam libel Nbid. 3S I E1attV Rack /svmg t ee AmpHr I+neler pea 'gPlInU5181 Lxalnr NetSure 7100 DC Power System System Application Guide Rectlflsrs RrmeaMr Metlub. p/N 1Rf6ifi00 i 'adPmvb.one(1)MadaIR48-3500e3,Sp..No.1R483500e.} 3W0 wen /-48 vaN rec[Mar module. Refer to the RetlHler InatruRlons (UM1R483500e3) for more Informahon. Reambebna For use In Spec. No. SBB]05400 module moun[Ing assembly. Orderine Notr 1) Order by P/N 1R4835UOe3 ae requlrad Each Spec Na. 588705400 madole - mounting eurmbly holds up roMx (8) reNlfls moduee. R.011. Module, P/N iR482000a3 Fsetur. • PravM. one n)Model R48-2000e3, Spec. No.1R482000e3, - 2000 wmt / -48 volt racdfier module. Refer to the RectHbr lnsRuctlons (UM1R482000e3) for more lnformanoo. R.trblbm Fur use m Spec. Na. 588705300 module mounting assembly. �.,. Ord.blp Not. 1) Order by PIN 1R482000e3 as required. Each Spec No. 588705300 modub .... ou ting.sambly holds up to IN (6)ract'rfier modules. THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. RECTIFIER SPECIFICATION THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S)WITH 2 RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS SCALE: NOT TO SCALE DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. NetSure7 7100 DC Power System System Application Guide Converters oo-oc cenl.rt.r Mmab. a/N u•�a+No. Feet=♦ Pr.1d.one(1)MadeIC400/48-3500e.5pec.No1C400483500e, —I.. V ID -48 V a -DC converter madub. • Itemrmtne wnverter manaatbna(uMlc4co4aasooe)mr more lnrormetan. 9 p Reetrictle. For use In Spec. Na588105000 modub maun[Ing euembty Lists 40, 41, 42. 1 Orderlro Not 1) Order by PIN iC400483W0e u required. Each Spec No.5e87OW00 module mountlnB ammbly home up m elx (8)converter maduba DGOC Convener Medub. p/N 1C4a241600 - 31.81 [stuns ♦ Provid.—(1)Model C48/24-1500, Spec. No. 1C4824IWO, 1WO watt / -48 V to ♦24V converter module. Front View ♦ RMertotheCan,arterinstructlm,(UM1C48241500)formorelnfonnatlom )t.clgeloR. For use In Sp.. N..58VO5WO —dule moumirg assembly. ®� Converters can be insmlled in mein by only. Must be used with List 60. ordermp Not. 1) Order by P/N1C48241500asrequired. Each Spec Nn588705300moduiemoun8ngessemblyhold...t hree(3) converter modules (far right three mouming pasttians es viewed from the fronO. INTERNAL VIEW OF LEFT4UNG WALL THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. CONVERTER SPECIFICATION THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH ' RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS SCALE: NOT TO SCALE DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. Suva SupP� ) NN15ue 51I n sy tam 2.5 Enclosure Dimensions, Weights, and Physical Specifications Nnar Gmalnd R. • Illustrations: I ppoatlm) — Fig. 3 and Fig.4 provide enclosure dimensional illustrations. — Fig. 5 provides an enclosure base plate dimensional illustration. — Fig. 6 illustrates the pad mounting rubber harrier. — Fig. 7 illustrates the optional re -usable pad mounting template. lamer — Fig. 8 illustrates the optional pour -in- lace ad mounting template. 8� P� P P P 8 P urlbm�l Height: 72.06" (183.03 cm). • Width: 31.81"(80.80 cm). • Depth: 39.02" (99.11 cm). • Equipment and Battery Compartments Dimensions: Refer to Fig. 4. • Typical Weights: Shipping weight: 884 lb (401 kg). — Lift weight: 752 lb (341 kg). — On pad, with rectifiers and converters installed but without batteries: 778 lb (353 kg), not including customer equipment and cabling. — On pad with rectifiers, converters, and batteries installed: 2206 It, (1001 kg). Note: The enclosure is not to be lifted with batteries, rectifiers, or conveners in place. All batteries, rectifiers, and converters are to be installed once the enclosure is secured to the pad BATTERIES CANNOT BE LIFTED WITH THE ENCLOSURE! Note: Battery weight is based on Northstar NSB I SOFT 180Ah Batteries weigh 129 lb (58.5 kg) each. A complete set of SAFT Batteries (10 units per shelf) weighs 357 lbs (162 kg). Note: Pad weight excludes incoming OSP cables. • Color. Off-white. • Finish: Finished in multistage dry powder polyester paint for maximum durability and performance against corrosion. • Lifting: The enclosure has four lifting eyebolts on the top that allows it to be lifted and lowered into position. THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH DC POWER PLANT SPECIFICATION ,I RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS SCALE: NOT TO SCALE DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. DIMENSION &WEIGHTS THEREFORE, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS ` DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE \� SCALE: NOT TO SCALE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. /O GPD GROUP Professional Corporation 5205o 1, Main Street, 5-12531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 %%M asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 w Z O w z EL Of W W U U o 00 0 Of O c- O LL O LL W W W Ob Lu N W N o a >L Q In U RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM SEAL r '^ Z Z a0 Z 0<0 jo J aH N J a Q LL Z WV LL _ o O CU as W U ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD DESIGNER r77� MSG GPD JOB NO. 2021723.06.74953.01 C=8 GROUNDING PLAN LEGEND: GROUND BUSS BAR NOTE: --- EXISTING GROUND WIRE --- NEW GROUND WIRE (� COPPER GROUND ROD 1. BURNDY GROUNDING CLAMP REQUIRED BOND BUSS BAR TOWER STEEL. ATTACH BURNDY CLAMP (GAR3903T3TC, TESSCO#542362) 2)TO ROUND MEMBER BELOW BUSS BAR OR PARALLEL TO GROUND BUSS BAR. ■ EXOTHERMIC WELD BURNDY CLAMP SHALL NOT BE INSTALLED ABOVE BUSS BAR. GROUND ROD 2_ IF EXISTING BUSS BAR IS TO BE RE -USED, INSTALL BURNDY BONDING • MECHANICAL CONNECTION W/ TEST WELL STRAP FROM BUSS BAR TO TOWER STEEL AS NOTED ABOVE. GENERAL NOTES: 1. CONTRACTOR SHALL HAVE A COMPLETE UNDERSTANDING OF THE CONTENTS OF AT&T STANDARD TP-76416. 2. ALL GROUNDING CONDUCTORS SHALL PROVIDE A STRAIGHT DOWNWARD PATH TO GROUND WITH GRADUAL BEND AS REQUIRED. GROUND WIRES SHALL NOT BE LOOPED OR SHARPLY BENT. 3. KOPR-SHIELD ANTI -OXIDATION COMPOUND SHALL BE USED ON ALL COMPRESSION GROUNDING CONNECTIONS. 4. ALL EXOTHERMIC CONNECTIONS SHALL BE INSTALLED UTILIZING THE PROPER CONNECTION/MOLD AND MATERIALS FOR THE PARTICULAR APPLICATION. 5. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH AN EXTERNAL TOOTHED LOCK WASHER. GROUNDING BUS BARS MAY HAVE PRE -PUNCHED HOLES OR TAPPED HOLES. ALL HARDWARE SHALL BE SECURITY TORQUE HARDWARE 31 8.. STAINLESS STEEL. 6. EXTERNAL GROUNDING CONDUCTOR SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES IN ANY METAL OBJECTS, CONDUITS, OR SUPPORTS TO PRECLUDE ESTABLISHING A MAGNETIC CHOKE POINT. 7. PLASTIC CLIPS SHALL BE USED TO FASTEN AND SUPPORT GROUNDING CONDUCTORS. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING CONDUCTOR SHALL NOT BE USED. 8. CONTRACTOR SHALL REPAIR/PLACE EXISTING GROUNDING SYSTEM COMPONENTS DAMAGED DURING CONSTRUCTION AT THE CONTRACTORS EXPENSE. 9. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 10. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MANUFACTURERS PRACTICES. 11. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 12. CONTRACTOR TO VERIFY AND TEST GROUND SOURCE, GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY WIRELESS REPRESENTATIVE. 13. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 14. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED WIRELESS REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RINGS. 15. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 16. USE PANI SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. GROUND ROD NOTES: 1. ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTILIZING THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU. 2. POINT GROUND TEST OR 3 POINT 62 % TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY. CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS ARE MADE WITH #2 STRANDED GREEN INSULATED COPPER CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID TINNED COPPER CONDUITS (ATT-TP-76416 7.6.7). HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND RING WITH (2) #2 STRANDED GREEN INSULATED COPPER CONDUCTORS. WHEN A HATCH -PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH PRESENT, THE CELL SITE REFERENCE GROUND BAR MUST BE CONNECTED TO THE HATCH -PLATE AND TO THE INTERIOR GROUND RING USING (2) #2 STRANDED GREEN NSULATED COPPER CONDUCTORS. EXTERIOR CABLE ENTRY PORT GROUND BARS: LOCATED AT THE ENTRANCE TO THE CELL SITE BUILDING. BOND TO GROUND RING WITH A #2 SOLID TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD AND INSPECTION SLEEVE (ATT-TP-76416 7.6.7.2). DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICES CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH MASTER DC SYSTEM RETURN GROUND CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE REFERENCE GROUND BAR PER TP76300 SECTION H 6 AND TP76416 FIGURE 7-11 REQUIREMENTS. GAMMA 300, EXISTING SECTOR GROUND BAR LOCATED AT EACH SECTOR (FIELD VERIFY LOCATION) -SEE DETAIL 5 ON SHEET G-2 GAMMA 300' MECHANICAL LUG CONNECTION (TYP.) -SEE DETAIL 6 ON SHEET G-2 AW j 3 #2 AWG GROUND LEAD FROM SECTOR I BAR TO TOWER TOP COLLECTOR I BAR (FIELD VERIFY) EXISTING TOWER TOP COLLECTOR GROUND BAR (FIELD VERIFY LOCATION) !XISTING #2 AWG GROUND TOWN LEAD (FIELD VERIFY) kD FROM NEW DIPLEXERS TO EXISTING SECTOR GROUND BAR (TYP.) -SEE DETAIL 3 ON SHEET G-2 BETA 200' PROPOSED ANTENNA PLAN 31'-0" RAD x SCALE: N.T.S. p Z BETA 200' PROPOSED ANTENNA PLAN 38'-6" RAD 2 SCALE: N.T.S. ALPHA 60, WG GROUND LEAD FROM NEW NOKIA AEQK ANTENNA TO EXISTING SECTOR GROUND BAR (TYP.) -SEE DETAIL 3 ON SHEET G-2 /O GPD GROUP Professional Corporation 5205o h Main 5tteIt, 5uite2531 Akron, OH"311 330.572.2100 Fax 330.572.2101 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 41 asTec Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w w z EL >w K U cUU o o O a O LL O o w 0 w w Lu m w m m � m Lu o a W Q m U D_ RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELECTRICAL SEAL Z c >o 0 U Z OQ Na3 00 a1 �Q 0 Z� QLL0 O= =moo W wU C� cn ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION --- RECORD PROJECTMANAGER D!MA.NER CB GPD JOB NO. 2021723.06.74953.01 G-1 B n■ 0 ■ -i�& c'm 1�4 TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY TYPE W TVPE VN TYPE NC TYPE SS TYPE GR TYPE VS TYPE VB TYPE PT TYPE GT' NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. 2 TO ANTENNAS COAX JUMPER (TYP.) CONNEC WEATHERPROOFING (TYP. SEE NOl ANTENNA CA TO BTS EQUIPMENT (T 3 WEATHERPROOFING KIT (TYP) 3ROUND KIT (TYP) AWG DPPER/GALVANIZED COAX ROUND BAR BONDED RECTLY TOWER NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. CADWELD GROUNDING CONNECTIONS �� GROUND CABLE CONNECTION (^� t SCALE: NOT TO SCALE SCALE: NOT TO SCALE NOTE: MINIMUM OF S/S NUT 3 THREADS TO BE (TYP) VISIBLE (TYP) S/S SPLIT WASHER 2 HOLE LONG (TYP) BARREL TINNED SOLID COPPER LUG S/S FLAT WIRE SIZE BURNDY LUG BOLT SIZE (TYP) WASHER (TYP) #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT TIN COATED SOLID COPPER BUS BAR S/S FLAT WASHER (TYP) CHERRY INSULATOR INSTALLED IF REQUIRED S/S BOLT (TYP) ��� GROUND CABLE CONNECTION `f SCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. ICE BRIDGE, OR ON ANTENNA TOWER 'TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING ROUNDING SHALL E ELIMINATED 'HEN GROUND AR IS _LECTRICALLY BONDED TO METAL TOWER �GROUNDWIRE INSTALLATION INSTALLATION SCALE: NOT TO SCALE #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" -16 NC S 2 BOLT #210 AWG STRANDED YA26-2TC38 3/8" - 16 NC S 2 BOLT #4/0 AWG STRANDED YA28-2N 1/2" - 16 INC S 2 BOLT BURNDY GROUND LUG W/ LONG BARREL HEAT SHRINK (SEE CHART) (CLEAR) NUT GROUNDING (TYP) CONDUCTOR LOCK WAS (TYP) GROUNDBAR BOLT (SEE CHART) (TYP) HOLE LUGLTO BE OTH ENDS ED(GREEN INSULATED) ONLY FOR#6 I AWG ART) NOTES: 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. MECHANICAL LUG CONNECTION SCALE: NOT TO SCALE 4 (N) COPPER GROUND J (N)1/2" COAX JUMPER J BUS BAR. GROUNDING DETAIL �SCALE: NOT TO SCALE E ■ STAINLESS STEEL BOLT (TYP) STAINLESS STEEL FLAT WASHER HOLE CRIMP/ (TYP)C COMPRESSION CONNECTOR , u GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYP) BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYP) STEEL 2-HOLE CRIMP/ COMPRESSION STEEL CONNECTOR J��F1'WASHERAINLESS YP) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYP) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF -DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYP) (TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS (D HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE AO GPD GROUP Professional Corporation 5205o hMain 5tteet, 5-12531 Akron, OH4 311 330.51.21 oo Fox 330.52.2101 SURGE f� SUPPRESSION11 Mobility 19801 SW 72ND AVENUE, STE. 200 7UALATIN, OR 97062 41 asTe Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 Z w w z EL >W W U U o 00 0 O a O LL O LL W W W W f/1 W m W m m � m o a W Q m U !r RECEIVED Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELECTRICAL SEAL Z O >o Z N JQ J a� z Z :3 Q H =a)o W W ,�� V ISSUED FOR: REVIEW 12/14/21 PERMIT - CONSTRUCTION --- RECORD DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 G=2 1 C B A 2 3 TOP RC (On Cupola Extension) Ant Pos 5 AroK Sector A Ant Pos 6 — — — — — — — Hatch Plate_ — — — — — 4 5 &L GPD GROUP Professional Corporation 5205—h Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 41�c1 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 RECEIVE Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELECTRICAL SEAL O V Zwo Z� OW N Q � Q � LLz J Q a ro a =°W �o ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION — RECORD — DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 RF-1 1 C B A 2 3 TOP RC (On Cupola Extension) Ant Pos 5 AroK Sector B Ant Pos 6 — — — — — — — Hatch Plate_ — — — — — 4 5 &L GPD GROUP Professional Corporation 5205—h Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 41�c1 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 Network Solutions 22263 68TH AVENUE SOUTH KENT, WA 98032 RECEIVE Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELECTRICAL SEAL O V Zwo Z� OW N Q � Q � LLz J Q a ro a =°W �o ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION — RECORD — DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 RF-2 2 CI BI AI 3 Sector C TOP RC (On Cupola Extension) Ant Pas 5 Ant.Pos 6 BauEand Unit IWALd 6051 [WseWM Unk Power Pldnt OYAwNaoibo5) 4 5 &L GPD GROUP Professional Corporation 5205—h Main Street, Suite 2531 Akron, OH"311 330.572.2100 Fax 330.572.2101 41�c1 Mobility 19801 SW 72ND AVENUE, STE. 200 TUALATIN, OR 97062 Network Solutions 2226368TH AVENUE SOUTH KENT, WA 98032 RECEIVE Apr 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ISSUED FOR: REVIEW 12/14/21 PERMIT — CONSTRUCTION — RECORD — DESIGNER r77� MAS GPD JOB NO. 2021723.06.74953.01 RF-3 60"± LONG, 4"x4"x3/8" 4ft�— vo FRP SINGLE ANGLE. �� COPE AS REQUIRED FOR FIT. -H .r° t&t co 00 2 3 S-2 ■ ■ a S-2 ■ im Network Solutions 22263 68TH AVENUE SOUTH l KENT, WA 98032 144" LONG, 4"x4"x3/8" RE LIVED 00 FRP SQUARE TUBE Ar r252023 CI DEVEL Y OF EDMONDS OPMENT SERVICES EPARTMENT • • • ` • • l ry on 00 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 co 1-855-669-5421 32" LONG, 4"x4"x3/8" L 00 FRP SQUARE TUBE RECEIVED Apr 25 2023 N CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STEEPLE FRAMING_ ISOMETRIC VIEW SCALE: NTS 1 STEEPLE FRAMING FRONT ELEVAT ON SCALE: NTS 2 DRAWING SCALES ARE INTENDED FOR 24"x36" SIZE PRINTED MEDIA ONLY. ALL OTHER PRINTED SIZES "NOT ARE DEEMED TO SCALE". 44"± LONG, 4"x4"x3/8" SUBMITTALS FRP SINGLE ANGLE. REV DATE DESCRIPTION BY CONNECT TO HZ. FRP 60"± LONG, 4"x4"x3/8" 0 03/01/23 FOR CONSTRUCTION KJT 144" LONG, 4"x4"x3/8" SQUARE TUBE w/ (3) FRP SINGLE ANGLE. „ i 36 TYP. FRP SQUARE TUBE 1 /2 RESIN BOLTS SPACED COPE AS REQUIRED FOR IN owl 12" O.C. FIT. -- a �O O 32" LONG, 4"x4"x3/8" FRP SQUARE TUBE 20"± LONG, 4"x4"x3/8" FRP SINGLE ANGLE. CONNECT TO S 2 FRP SINGLE ANGLE w/ (2) 1 /2" RESIN BOLTS. SITE INFORMATION SITE NAME: O H O HARRISON o O N 0) O SITE ID: � WA6272 32" LONG, 4"x4"x3/8" FRP SQUARE TUBE SITE ADDRESS: 9617 FIRDALE AVE., EDMONDS, WA 98020 SHEET DESCRIPTION O O l 1 FRP STEEPLE DESIGN SHEET No. S-1 COLUMN LAYOUT -PLAN VIEW SCALE: NTS 3 CUPOLA PLAN V EW SCALE: NTS 4 4"x4"x3/8" FRP SINGLE ANGLE. 3/8" FRP PLATE t&t 2" //- EPDXY 4"xCX3/8" /A\ FRP PLATE TO FRP CORNER ANGLE r'�, mm ■ 11 a sTe c Network Solutions 22263 68TH AVENUE SOUTH N KENT, WA 98032 RE EIVED Apr 25 2023 CIF DEVEL Y OF EDMONDS OPMENT SERVICES DEPARTMENT , y • • • •� rylon D 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 1-855-669-5421 i� 10 1 /4" MIN 1 1 /1 6" HOLE TO 3/8" FRP BENT PLATE 11/16" HOLE FOR 5/8 RESIN BOLT 4"x4"x3/8" FRP BENT ANGLE ACCOMMODATE 5/8" RESIN BOLT RECEIVED Apr 252023 CITY EDMONDS DEVELOPMENT SERVICES DEPARTMENT ROOF ANGLE ATTACHMENT SCALE: N TS 1 COLUMN ATTACHMENT CLIP 2 DRAWING SCALES ARE INTENDED FOR 24"x36" SIZE PRINTED MEDIA ONLY. ALL OTHER PRINTED SIZES "NOT ARE DEEMED TO SCALE". SUBMITTALS REV DATE DESCRIPTION BY 0 03/01 /23 FOR CONSTRUCTION KJT 4"x4"x3/8" FRP SINGLE ANGLE. 2" 2" 1 1 /1 6" HOLE TO ACCOMMODATE 5/8" RESIN BOLT SITE INFORMATION SITE NAME: N HARRISON SITE ID: WA6272 N SITE ADDRESS: 9 617 FIR DALE AVE., EDMONDS, WA 98020 SHEET DESCRIPTION CONNECTION DETAILS SHEET No. S-2 CLIP ANGLE DETAIL SCALE: NTS 3 NOT USED 4