BLD2023-0511+Letter+4.25.2023_9.27.14_AM+3503185RECEIVED
Apr 25 2023
DEVELOPMENT SERVICES
.:-MasTec
Project Narrative Network Solutions
BLD2023-0511
1351 E. Irving Park Road 1 (810) 874-8218 1 Maggie. Barringer@mastec.com
4/25/2023
City of Edmonds
121 5th Ave N
Edmonds, WA 98020
Dear Development Services Permit Processing:
Project Description: WA6272 AT&T Upgrades
I am submitting an application for Land Use Approval services for WCF modification. The modifications will
be taking place on an existing tower site located at: 9617 Firedale Ave. The height of the structure and the lease
space will not be affected by this scope of work. The scope of work qualifies as an Eligible Facilities Request for
a minor modification under Section 6409a. (Please note: all work will be performed wholly within the existing
premises and utility easements; this site is free of any concealment features; and the project otherwise complies
with the site's original conditions of approval.) The pole and pole mounted antennas and equipment shall
remain painted brown. No changes are proposed to the chain -link fencing and exterior of equipment shelters.
Component
Federal Section 6409 Limits
AT&T's Proposed Modification
Increase height of original structure
10 feet or less
No increase in height.
Antennas extending horizontally from edge
of structure
6 feet or less
Antennas extend less than 6 feet horizontally from
edge of structure
Additional equipment cabinets
4 or fewer, with no cabinets larger than
the existing cabinets
No additional equipment cabinets will be installed.
Below is a detailed project description for your review: TOWER SCOPE OF WORK:REMOVE ALL EXISTING MOUNTS,
INSTALL (3) NOKIA AEQK ANTENNAs, NSTALL (6) KATHREIN 782 11288 DIPLEXERs, NSTALL (3) NEW MOUNTS W/
MOUNT PIPES, INSTALL NEW FRP STEEPLE DESIGN BY TRYLON GROUND SCOPE OF WOR, REMOVE (3) KAELUS
DBC0135F3V92-1 DIPLEXERs, REMOVE EXISTING ARGUS DC POWER PLANT & CABINET, REMOVE (20) EXISTING 145AH
BATTERY CELLS, INSTALL (1) DC12-48-60-0-25E OVP, NSTALL (1) ASIK & (1) ABIL IN EXISTING SUBRACK C2, INSTALL
(1) AMIA, (3) ABIA, & (1) ASIA IN EXISTING SUBRACK C1, INSTALL NEW -48V VERTIV NETSURE 512 OUTDOOR DC
POWER, PLANT CABINET W/ (11) RECTIFIERS & (2) CONVERTERS, REUSE EXISTING BATTERY CABINET &
RECONFIGURE W/ (5), STRINGS OF 180AH BATTERIES (20 TOTAL BATTERIES), PROPOSED (N) STEALTH CUPOLA AND
MOUNTING FIXTURE, (DESIGNED BY OTHERS) TO BE INSTALLED
Sincerely,
Maggie Barringer
Zoning and Permitting Specialist
1351 E. Irving Park Road, Itasca, IL