Loading...
REVIEWED BLD2022-1181+Energy_Code_Sheet_or_Envelope_Summary+9.6.2022_11.15.25_AM+3091208RECEIVED Sep 29 2022 ENVELOPE COMPLIANCE SUMMARN, DE EILO MF NDT SOERV CES DEPARTMENT 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 M A I N P E R Ministered by: 02022 NEEA, All rights reserved P ,ject&RAMIFWED In ormation BY CITY OF EDMONDS Project Title Firdale Village II Fire - 2018 WSEC For Building Department UsB L D2022-1181 I Date' Aug 22, 2022 OTHER UNITS: BLD2022-1182 & RLD2022-1 18 3 Project Address 9617 Firdale VIllage Ave Edmonds, WA98020 Applicant Name Jesse Binford Applicant Phone 253-833-5557 Applicant Email ccruz@bcie.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport(cUwaenergycodes.com General Occupancy All Commercial General Building Use Type Retail, Convenience Store Building Cond. Floor Area 3,582 Project Scope New Building Space Conditioning Categories Fully Conditioned Project Cond. Floor Area 3,582 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description Rebuild structure back over existing foundation. Envelope Compliance Scope Scope Space Conditioning Category Compliance Method W WR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification and Method New Building Fully Conditioned Prescriptive 22.30% / 0`/` None selected No alternates selected COMPLIES Air Barrier Testing I Air barrier testing included in project scope I Air Barrier Comments Project Title Firdale Village II Fire - 2018 WSEC _T Date Aug 22, 2022 Scope &Space Condition' NEW BUILDING - FULLY CONDITIO Compliance Verification COMPLIES Window -to -wall Ratio 22.30`; Skylight -to -roof -ratio o% I Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof) U-Factor Net Area (SF) Joist or single rafter AO.0, A2.0, A2.1 & A2.2 Roof - Main Floor (Rafters) Exterior R-38 I R-38 (< 0.04%) U-0.027 287 U-Factor Source: WSEC Appendix A U-Factor Source Description: Roof Framing Type (Standard, Advanced): Advanced Roof Framing Material: Wood -framed Ceiling/Attic Venting: Unvented Is this assembly exterior or interior?: Exterior Joist or single rafter AO.0, A2.0, A2.1 & A2.2 Roof -Main Floor (22" Roof Trusses) Exterior R-38 I R-38 (< 0.04%) U-0.027 1,655 U-Factor Source: WSEC Appendix A U-Factor Source Description: Roof Framing Type (Standard, Advanced): Advanced Roof Framing Material: Wood -framed Ceiling/Attic Venting: Unvented Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood -framed and other - Commercial AO.0, A2.0, A2.1 & A2.2 Furring Walls Interior partition R-21 R-21 (< 0.04%) U-0.054 905 Which insulation code target does wall comply with?: Wall Assembly U-factor U-Factor Source: WSEC Appendix A U-Factor Source Description: Framing Depth: 2x4 Framing Spacing: 16 Is this assembly exterior or interior?: Interior partition Wood -framed and other - Commercial A1.0 Existing 2x4 Party Wall Exterior R-15 R-15 (< 0.04%) U-0.054 347 Which insulation code target does wall comply with?: Wall Assembly U-factor U-Factor Source: U-Factor Source Description: Framing Depth: 2x4 Framing Spacing: 16 Is this assembly exterior or interior?: Exterior Wood -framed and other - Commercial AO.0, A2.0, A2.1 & A2.2 Exterior Walls Exterior R-21 I R-21 (< 0.04%) U-0.054 1,2(l9 Which insulation code target does wall comply with?: Wall Assembly U-factor U-Factor Source: WSEC Appendix A U-Factor Source Description: Framing Depth: 2x6 Framing Spacing: 16 Is this assembly exterior or interior?: Exterior Floors and Edges Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) U-Factor Net Area (SF) Wood-framing/joist A0.0, A1.0, A2.0, A2.1 & A2.2 I Main Floor Framing (Office, Storage) Exterior R-30 I R-30 (< 0.04%) U-0.029 287 U-Factor Source: U-Factor Source Description: Floor Framing Type (Joist, Post & Beam): Wood Joist Framing Depth: 2x 12 Is this assembly exterior or interior?: Exterior Slab -on -grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A0.0, A2.0, A2.1 & A2.2 I Existing slab Below grade R-00 F-0.54 194 Slab Insulation Method: Uninsulated slab F-Factor Source: F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Vertical Fenestration Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed - Class AW or site built A0.0 & Al.1 A Exterior North Facing I PF < 0.2 SHGC-0.51 U-0.38 84 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Fixed - Class AW or site built A0.0 & Al.1 A Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.38 84 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Fixed - Class AW or site built A0.0 A Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.38 168 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Operable - Class AW or site built A0.0 & ALI B Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.40 13 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Glazed Doors Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Swinging entrance door A0.0 & Al.1 2 Exterior North Facing I PF < 0.2 SHGC-0.51 U-0.60 25 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule Swinging entrance door A0.0 & Al.l 2 Exterior North Facing PF < 0.2 SHGC-0.51 U-0.60 25 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule Swinging entrance door A0.0 & A1.0 1 Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.60 49 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Project: Firdale Village II Fire - 2018 WSEC 9617 Firdale Vlllage Ave Edmonds, WA 98020 Date: 2022-08-22 Applies Code Section Component Compliance Information Required In Permit Location in Building Department Documentation Documents Notes SCOPE C103.1 Construction For a tenant space (first build -out) project, documents - General indicate if there is no envelope scope included in the project. C103.1 Construction For an alteration project, indicate if there is documents - General no envelope scope included in the project. C402.1.1.1 Low energy spaces Identify low energy spaces on plans; include calculations if applicable that demonstrate eligibility for envelope provisions exemption C402.1.1.2 Semi -heated spaces Identify semi -heated spaces on plans, include mechanical heating system type and calculations that demonstrate eligibility for wall insulation exemption C402.1.1.3 Greenhouse spaces Identify greenhouse spaces on plans; include non -opaque assembly information and mechanical heating system type if applicable, that demonstrates eligibility for envelope provisions exemption C402.1.2 Equipment buildings Provide building sf area, average wall and roof U-factor, installed electrical and mechanical equipment information and heating setpoint restriction, that demonstrates eligibility for envelope provisions exemption NA C402.1.2.1 Standalone elevator Provide building area, average wall and roof hoistways U-factor, installed mechanical equipment information and heating setpoint restriction, that demonstrates eligibility for envelope provisions exemption C410.2 Walk-in cooler and Identify walk-in cooler and freezer spaces on freezer spaces plans; including site assembled, site constructed and prefabricated units Identify warehouse cooler and freezer spaces on plans C101.4.1 Mixed residential & Identify spaces with different occupancy commercial building requirements on plans C503.2 Change of space Identify on plans existing unconditioned conditioning spaces changing to semi -heated or conditioned alteration space, and existing semi -heated spaces changing to conditioned space; provide calculations for existing and final level of space conditioning C505.1 Change of occupancy Identify on plans existing F, S and U- alteration occupancy spaces undergoing a change in occupancy and final occupancy type Page 119 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Group R spaces permitted before July 1, 2002 that are undergoing a change to a commercial occupancy shall be identified on plans Commercial (non -Group R) occupancy spaces undergoing a change to Group R shall be identified on plans ENVELOPE PROVISIONS YES C103.2 Compliance Indicate envelope thermal performance Prescriptive C103.6.3 documentation compliance path (prescriptive or component C402.1.3 performance) and provide WSEC envelope C402.1.4 compliance reports C402.1.5 NA If complying via component performance, demonstrate that the Proposed Total UA is equal to or less than the Allowable Total UA If complying via total building performance, provide a list of all proposed envelope component types, areas and U-values YES C303.1.1 Insulation Indicate identification mark shall be applied A0.0, A2.0, A2.1 & C303.1.2 identification to all insulation materials and insulation A2.2 installed such that the mark is readily observable during inspection YES C303.1.3 Fenestration product Indicate fenestration products shall be labeled A0.0 C402.4.3 rating with NFRC U-factor, SHGC, VT and leakage rating, or if products do not have an NFRC rating, indicate applicable Chapter 3 default values YES C303.1.1 General insulation Indicate installation methods, thicknesses, A2.0, A2.1 & A2.2 C402.2.1 installation densities and clearances to achieve the intended R-value of all insulation materials NA Where two or more layers of rigid insulation will be used, indicate that edge joints between layers are staggered, or exception taken YES C103.2 Roof assembly Indicate R-value(s) of cavity/continuous A2.0, A2.1 & A2.2 C402.2.1 insulation insulation on roof sections YES Indicate framing materials on roof sections A2.0, A2.1 & A2.2 NA Indicate method of framing for ceilings below Unvented vented attics and vaulted ceilings per A102.2 (std, adv) NA Provide area weighted average U-factor calculation for insulation whose thickness varies by 1 inch or less NA Indicate effective U-factors of tapered insulation entirely above deck per A102.2.6; include roof configuration and slope, maximum R-value at peak and minimum R- value at low point for all roof surfaces NA Indicate R-values for thermal spacers and each insulation layer, and liner system (LS) method for metal building roofs Page 219 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C402.2.1.1 Skylight curb Indicate skylight curb insulation R-value on insulation roof section, if not included in skylight NFRC rating NA C402.2.1.2 Rooftop HVAC Indicate rooftop HVAC equipment curb equipment curbs insulation R-value on roof section YES C103.2 Above/below grade Indicate R-value(s) of cavity/continuous A0.0, A2.0, A2.1 & C402.2.3 wall insulation insulation on wall sections A2.2 C402.2.4 YES C303.2.1 Indicate framing materials on wall sections A2.0, A2.1 & A2.2 YES Indicate method of framing for wood A2.0, A2.1 & A2.2 construction per A103.2 (std, int, adv) NA Indicate material density category, wall weight and heat capacity for qualifying mass walls NA For qualifying ASTM C90 masonry walls, indicate loose -fill core insulation material and percentage of cores filled including grouted cores, bond beams, vertical fills, headers and any other grouted cores NA Indicate method of protection of exposed exterior basement/crawlspace wall insulation YES C103.2 Opaque doors Indicate rated U-factor or R-value (non- A0.0 C402.4.4 swinging) on wall sections or in door schedules - applies to doors with less than 50% glazed area NA C402.4.4 Garage doors Indicate rated U-factor for sectional and tilt - up garage doors on wall sections or in door schedules - applies to garage doors with less than 14% glazed area; all other garage doors shall comply as opaque doors YES C402.2.5 Floor over outdoor or Indicate R-value(s) of cavity/continuous A0.0, A2.0, A2.1 & unconditioned space insulation on floor sections A2.2 insulation YES Indicate framing material on floor sections A0.0, A2.0, A2.1 & A2.2 NA Indicate material density category and weight of qualifying mass floors C402.2.6 Slab -on -grade floor Indicate R-value of continuous insulation on C303.2.1 insulation wall section or foundation detail Indicate insulation extends down vertically and/or horizontally the required distance from top of slab Indicate method of protection of exposed exterior slab edge insulation Indicate R-value of continuous insulation on wall section or foundation detail Indicate insulation extends down vertically from top of slab and then horizontally under the entire slab Page 319 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Indicate method of protection of exposed exterior slab edge insulation NA C402.2.8 Radiant heating Indicate insulation R-value behind radiant system insulation panels, U-bend/headers and bottom surface of radiantly heated floors (other than heated slab - on -grade) YES C402.4.1 Vertical fenestration Provide total gross sf area of all above grade Energy Forms C502.2.1 maximum area wall elements and rough opening sf area of all vertical fenestration elements in the building, for the prescriptive max allowed window -to - wall ratio (WWR) calculation in the WSEC envelope compliance reports; demonstrate compliance for each space conditioning category separately C402.4.1.1 Increased prescriptive Provide calculations showing that not less that C405.2.4.1 maximum vertical 50% of the total conditioned floor area is C502.2.1 fenestration area with within a daylight zone; demonstrate daylight zones and compliance for each space conditioning controls category separately Indicate in envelope plans that all lighting fixtures located within daylight zones shall be provided with daylight responsive controls per Section C405.2.4.1 Indicate that the VT of vertical fenestration is at least 1.1 times the rated SHGC or no less than VT-0.55, whichever is greater C402.4.1.3 Increased prescriptive Indicate high performance U-factors and C502.2.1 maximum vertical SHGC values in fenestration schedules fenestration area with high-performance Indicate if an area -weighted U-factor is used glazing for multiple fenestration elements within the same fenestration category per Table C402.4; provide area -weighted U-factor calculation C402.1.5 Wall/vertical Indicate if component performance with fenestration target target area adjustment will be used to account area adjustment for vertical fenestration area in excess of the prescriptive maximum allowed; include target area adjustment in WSEC envelope compliance reports C402.4.1 Skylight maximum Provide total gross sf area of roof, and rough C502.2.2 area opening sf area of all skylight elements in the building, for the prescriptive max allowed skylight -to -roof ratio (SRR) calculation in the WSEC envelope compliance reports; demonstrate compliance for each space conditioning category separately C402.1.5.2 Roof/skylight target Indicate if component performance with area adjustment target area adjustment will be used to account for skylight area in excess of the prescriptive maximum allowed; include target area adjustment in WSEC envelope compliance reports Page 419 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C402.4 U-factors, SHGC and Indicate U-factors, SHGC and VT values in A0.0 C402.4.3.4 VT for all fenestration schedules C303.1.3 fenestration NA assemblies Indicate if an area -weighted U-factor is used for multiple fenestration elements within the same fenestration category per Table C402.4; provide area -weighted U-factor calculation NA Indicate if values are NFRC or default; if default then specify frame type, glazing layers, gap width, low-e coatings, gas -fill NA C402.4.3 Permanent shading For each group of windows with similar devices orientation and overhang or permanent projection geometry, provide projection factor calculations (Equation C4-6) for north and non -north orientations C402.4.2 Single story spaces Provide list of enclosed, single story spaces requiring skylights that exceed 2,500 sf; for each space identify the space use, floor area, floor to ceiling height, whether skylights are installed, and any exception taken Provide calculations for percentage of conditioned floor area located within a toplit daylight zone; if exception is taken for spaces where the total floor area minus the sidelit zone area is less than 2,500 sf, include percentage of conditioned floor area located within a sidelit daylight zone in calculations Provide calculations for percentage of skylight area in each space over 2,500 SF, OR Provide calculations for skylight effective aperture (Equation C4-5) for each space over 2,500 SF Indicate haze factor of skylight glazing material or diffuser NA C410.2 Walk-in and Indicate insulation R-value in cooler and warehouse cooler and freezer wall and ceiling assemblies freezer envelope NA Indicate cooler and freezer door insulation R- value; indicate method of minimizing infiltration (strip doors, curtains, spring - hinged doors, etc); provide automatic door closure (or note exception taken) NA For transparent reach -in doors and fixed windows, indicate number of glass panes (double or triple pane); identify whether the interstitial spaces between panes is filled with inert gas or if panes are heat -reflective treated glass ADDITIONAL EFFICIENCY CREDITS - ENHANCED ENVELOPE PERFORMANCE Page 519 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NO C406.10 Enhanced envelope To comply with additional efficiency credit, performance demonstrate envelope thermal performance compliance via component performance; provide WSEC envelope compliance reports that demonstrate Proposed Total UA is 15% lower than the Allowable Total UA AIR LEAKAGE NA C402.5.1.1 Air barrier Identify location and provide diagram of construction and sealing continuous air barrier in plans and sections NA Provide details for all joints, transitions in materials, penetrations in air barrier and note method of sealing (caulked, gasketed, or other approved method) NA C402.5.3 Rooms containing For room(s) located within the conditioned C402.1.3 fuel burning space space that contain non -direct vent fuel- C402.1.4 conditioning burning appliances that require outdoor air for appliances combustion, indicate method of isolation from the conditioned space; include sealing of walls, floor and ceiling of room, doorway gasketting and sealing around ductwork and piping penetrations NA Indicate walls, floor and ceiling of the room envelope are insulated to the same level required for exterior envelope, and combustion air ductwork that passes thru conditioned space is insulated to at least R-8 NA C402.5.4 Doors and access Indicate locations of all doors and access openings to shafts, openings to shafts, chutes, stairways and chutes, stairways and elevator lobbies elevator lobbies NA Indicate method of sealing of these openings (gasketing, weatherstripping, other sealing method); or exception taken NA C402.5.5 Outdoor air intakes, Indicate locations of all stairway enclosure, C403.7.8 exhausts and relief elevator shaft and building pressurization openings relief openings, outside air intakes and exhaust openings NO Note in envelope plans that all relief, outside air intake and exhaust openings shall be provided with dampers in accordance with Mechanical Section C403.7.8 NA C402.5.8 Recessed lighting in Indicate method of sealing between light building envelope fixture housing and wall or ceiling NA Note in envelope plans that all recessed lighting fixtures shall be IC rated and have an air leakage rating not greater than 2 cfm per ASTM E283 test; include these requirements in lighting fixture schedules NA C402.5.6 Loading dock seals Indicate weather seal at cargo and loading dock doors Page 619 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C402.5.7 Vestibules Indicate locations and dimensions of vestibules for building entrances; also indicate vestibule information for exit -only doors in buildings where separate doors for entering and exiting are provided NA Indicate locations of all building entrances and exit -only doors provided with an air curtain in lieu of a vestibule NA Indicate exception and criteria utilized for all building entrances and exit -only doors that do not have a vestibule or air curtain NA Indicate required performance for air curtains installed per Exception 7 NA For unconditioned vestibules, indicate which envelope assembly (interior or exterior) complies with the requirements for a conditioned space YES C103.2 Building enclosure air Indicate in project documents that building C402.5.1.2C leakage test enclosure air leakage testing is required for 402.5.1.2.1 WSEC compliance R402.4.1.2 NA Provide area calculations that account for all six sides of the air barrier boundaries YES For commercial buildings, indicate that building enclosure air leakage testing shall be performed per ASTM C779 (or equivalent method approved by the code official) and the target leakage rate is 0.25 cfm/ft2 (1.5 L/s*m2) at 0.3 in. wg (75 Pa) NA If the building is mixed residential / commercial and three stories or less above grade plane, indicate which building enclosure air leakage test procedure will be used for the Group R-2 / R-3 areas (Section R402.4.1.2 or C402.5.1.2); if per R402.4.1.2, indicate that the target leakage rate is 5 air changes per hour at 0.2 in. wg (50 Pa) YES Include the following requirements in project A0.0 documents: (1) Submit building enclosure air leakage test reports to jurisdiction and owner; (2) If initial test result exceeds 0.25 cfm/ft2 (1.5 L/s*m2), indicate that inspection and all practical corrective actions be completed and documented in the air leakage test report; (3) If initial test result exceeds 0.40 cfm/ft2 (2.0 L/s*m2), indicate that corrective actions shall also include re -testing; (4) Indicate that corrective measures and retesting must be repeated until the test result is 0.40 cfm/ft2 (2.0 L/s*m2) or less; (4) Include air barrier test report in project close out documentation provided to building owner. ADDITIONAL EFFICIENCY CREDITS - REDUCED AIR INFILTRATION Page 719 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C406.9 Reduced air To comply with additional efficiency credit, infiltration indicate in project documents that the building enclosure air leakage test results shall not exceed 0.17 cfm/ft2 at 0.3 in. wg (75 Pa); all documentation requirements per C103.2 and C402.5.1.2 apply ALTERATIONS C503.1 Roof alteration - For a roof alteration where existing ceiling C503.3.1 insulation cavities are exposed, indicate cavities are insulated to full depth at minimum nominal value of R-3.0 per inch For a roof covering replacement where insulation is installed entirely above the roof deck, indicate insulation complies with requirements for new construction per Tables C402.1.3 or C402.1.4 C503.1 Wall and floor For a wall or floor alteration (floor over alteration - insulation outdoor or unconditioned space) where existing envelope cavities are exposed, indicate cavities are insulated to full depth at minimum nominal value of R-3.0 per inch C503.3.2 Addition of vertical Where the addition of new vertical fenestration fenestration results in a window -to -wall ratio (WWR) exceeding the prescriptive maximum allowed per C402.4.1, demonstrate method of compliance (prescriptive vertical fenestration alternate, component performance with target area adjustment for the alteration area and existing -to -remain areas combined, or total building performance per C407); demonstrate for each space conditioning category separately C503.3.3 Addition of skylights Where the addition of new skylights results in a skylight -to -roof ratio (SRR) exceeding the prescriptive maximum allowed per C402.4.1, demonstrate method of compliance (component performance compliance with target area adjustment for the alteration area and existing -to -remain areas combined, or total building performance per C407), demonstrate for each space conditioning category separately NA C103.2 Change in space Indicate envelope alteration thermal C103.6.3 conditioning or performance compliance path (prescriptive or C503.2 occupancy component performance with 110% C505.1 compliance allowance); provide WSEC envelope documentation compliance reports NA C103.2 Change in space If complying via total building performance C103.6.3 conditioning or with 110% allowance, provide a list of all C503.2C occupancy proposed envelope component types, areas 505.1 compliance and U-values documentation PROJECT CLOSE OUT DOCUMENTATION Page 819 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2022 NEEA, All rights reserved The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C103.6.3 Project close out Indicate in plans that project close out A0.0 documentation documentation is required including requirements applicable calculations, WSEC envelope compliance reports, and fenestration NFRC rating certificates Page 919 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: 02022 NEEA, All rights reserved Project & Applicant Information Project Title Firdale Village II Fire - 2018 WSEC For Building Department Use: I Date' Aug 22, 2022 Project Address 9617 Firdale Village Ave Edmonds, WA 98020 Applicant Name Jesse Binford Applicant Phone 253-833-5557 Applicant Email ccruz@bcie.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Retail, Convenience Store Building Cond. Floor Area 3,582 General Project Types New Building New Building or Addition Lighting Scope g g P Interior Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 3,582 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Lighting Project Description Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method New Building Interior Lighting Space by space Reduced lighting power density option COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Efficiency Options Included Reduced lighting power density credit Enhanced lighting controls credit Pr Firdale Village II Fire - 2018 WSEC IMF Date Aug 22, 2022 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification I COMPLIES Compliance Method Space by space LPA Calculation Adjustment1K I none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Lobby General 276 0.84 232 Lobby General 303 0.84 255 Office Enclosed less than 250 sf 138 0.74 102 Restroom General 67 0.63 42 Restroom General 67 0.63 42 Restroom General 67 0.63 42 Storage room General 124 0.38 47 Storage room 50-100 sf 52 0.38 20 Retail General sales 1 1,510 1.05 1 1,586 Proposed Total LPD I i 981 Totals 1 1 2,367 1 M 981 COMPLIES Proposed Lighting Power Density IL IF Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LIT x WpLF) Individual Fixtures Horizontal surface -mount C 5 26 1 130 Horizontal surface -mount A 11 50 550 Horizontal surface -mount C 1 26 26 Horizontal surface -mount B 2 25 50 Horizontal surface -mount C 5 26 130 Horizontal surface -mount A 1 50 50 Wall -mounted D 1 15 15 Wall -mounted D 1 15 15 Wall -mounted D I 1 15 15 Proposed Total LPD 981 Project Title Firdale Village II Fire - 2018 WSEC to Aug 22, 2022 Proposed Fixtures I Ir NEW BUILDING -INTERIOR LIGHTING Fixture Type/Application fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Horizontal surface- mount C A1.3 LED New Fixture Description: Surface Mounted Downlight Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Ultra -low total LPD (< 35% of total LPA) Do these fixtures require specific application lighting controls?: None required Horizontal surface- mount A A1.3 LED New Fixture Description: T-5 LED Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Street -level lighting in Group A-2 or M occupancy Do these fixtures require specific application lighting controls?: None required Horizontal surface- mount C A1.3 LED New Fixture Description: Surface Mounted Downlight Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface- mount B A1.3 LED New Fixture Description: Ceiling Mounted T-5 LED Lamp Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Street -level lighting in Group A-2 or M occupancy g p pp g g p p y Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Horizontal surface- mount C A1.3 LED New Fixture Description: Surface Mounted Downlight Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Ultra -low total LPD (< 35% of total LPA) Do these fixtures require specific application lighting controls?: Horizontal surface- mount A A1.3 LED New Fixture Description: Ceiling Mounted T-5 LED Lamp Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Wall -mounted D A1.3 LED New Fixture Description: Wall Mounted Vanity Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted D I A1.3 LED New Fixture Description: Wall Mounted Vanity Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted D I A1.3 LED New Fixture Description: Wall Mounted Vanity Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Firdale Village II Fire - 2018 WSEC Date Aug 22, 2022 Lighting Power Calculation NEW BUILDING -EXTERIOR LIGHTING Compliance Verification I COMPLIES Exterior Lighting Zone I ZONE 2 I Base Site Allowance - 1400 - Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub -Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Tradable Proposed Watts Tradable Compliance Status Building grounds Walkways < 10 feet wide 62 0.50 31 Building grounds Walkways 10 feet and wider 464 0.10 46 Building entrances and exits Entry canopies 301 0.25 75 Building entrances and exits Vehicular entrances & exits 37 14 518 Base Site Allowance 400 Totals 1,071 COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Wall -mounted F Building grounds - Walkways 10 feet and wider 3 55 165 Wall -mounted F Building entrances and exits - Entry canopies 2 55 110 Wall -mounted F Building entrances and exits - Entry canopies 1 55 55 Wall -mounted F Building grounds - Walkways < 10 feet wide 2 55 110 Wall -mounted F Building entrances and exits - Vehicular entrances & exits 3 55 165 Tradable Proposed Total 605 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Project: Firdale Village II Fire - 2018 WSEC 9617 Firdale Vlllage Ave Edmonds, WA 98020 Date: 2022-08-22 Applies Code Section Component Compliance Information Required In Permit Location in Building Department Documentation Documents Notes LIGHTING SCOPE C103.1 Construction For a shell & core or tenant space (first build - documents - General out) project, indicate if there is no lighting scope included in the project. C103.1 Construction For an alteration project, indicate if there is documents - General no lighting scope included in the project. LIGHTING CONTROLS YES C405.2 Lighting controls, For all lighting fixtures, indicate lighting A1.3 general control method on plans for spaces and lighting zone(s) served, or exception taken NA C405.2, Luminaire level Indicate on plans all fixtures provided with Option 2 lighting controls LLLC in lieu of C405.2 lighting controls; (LLLC) provide description of control capabilities and performance parameters C405.2.5, Lighting in dwelling Indicate method of automatic control of all Item 3 units (dormitory, installed luminaires in dwelling units in C405.2.1.1 hotel and all other buildings other than multifamily (occupancy C405.2.3.1 than multifamily) or light reduction controls) C405.2.5, Lighting in sleeping Indicate method of automatic off control of Item 2 units all installed luminaires in sleeping units (vacancy or key card control); also refer to Receptacles YES C405.2.3 Manual controls Indicate on plans the method of manual A1.3 C405.2.3.1 lighting control, location of manual control C405.2.5 device and the area or specific application it serves C405.2.3.1 Manual interior light Indicate on plans which method of manual C405.2.1.1 reduction controls 50% lighting load reduction is provided, or C405.2.4 indicate applicable exception YES C405.2.1 Method of automatic Indicate on plans the method of automatic A1.3 C405.2.2.1 shut-off control shut-off control during unoccupied periods C405.2.1, (occupancy sensor, time switch or digital Exception 3 timer switch) for all lighting zones YES C405.2.1 Occupant sensor Indicate on plans all luminaires that are A1.3 controls controlled by occupant sensor controls; indicate controls are configured to turn luminaires 100% off when the space is unoccupied YES C405.2.1 Occupant sensor Indicate if occupant sensor controls are A1.3 C405.2.1.1 controls configured to be manual on or automatic on to not more than 50% power; indicate spaces eligible for exception that allows automatic on to 100% power Page 1/10 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C405.2.1.2 Occupant sensor Indicate each aisleway and corridor within a controls - warehouses warehouse space are designated as separate spaces zones that are independently controlled NA Indicate occupant sensors are configured to automatically reduce lighting power by 50% when the zone is unoccupied and 100% off after the zone is unoccupied for over 20 minutes; indicate controls are configured to automatically restore lighting to full power when the zone or space is occupied NA C405.2.1.3 Occupant sensor For open plan office areas larger than 300 sf, controls - open plan indicate general lighting is provided with office areas vacancy controls that reduce lighting power by not less than 80% and are configured to turn luminaires 100% off when the space is unoccupied; indicate that no individual control zone area exceeds 600 sf C405.2.1.4 Occupant sensor Indicate parking garage general lighting is controls - parking provided with vacancy controls that reduce garages lighting power by not less than 30% and are configured to turn luminaires 100% off when no vehicles or pedestrians are present, unless eligible for an exception; indicate that no individual control zone area exceeds 3,600 sf NA C405.2.1.5 Occupant sensor Indicate stairway lighting is provided with controls - enclosed vacancy controls that reduce lighting power by fire -rated stairwells not less than 50% when the stairway in unoccupied YES C405.2.2.1 Automatic time Indicate spaces on plans where time switch A1.3 switch controls controls turn luminaires 100% off during unoccupied hours NA Indicate spaces on plans where time switch controls are configured to turn on lighting to full power versus 50% power NA Indicate locations of override switches on plans and the lighting zone(s) served; indicate that the area(s) served by each override switch does not exceeds 5,000 sf NA C405.2.1, Digital timer switch Indicate digital timer switch control includes: Exception 3 manual on/off, time delay, audible and visual indication of impending time-out YES C405.2.4.2 Daylight zones - Indicate primary and secondary sidelit A1.3 C405.2.4.3 Sidelit and toplit daylight zone floor areas on plans NA Indicate toplit daylight zone floor areas on plans NA For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone floor area) where daylight responsive controls are not required, provide fenestration area to daylight zone floor area calculation(s) Page 2110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C405.2.4 Daylight responsive Indicate on plans lighting zone(s) served by A1.3 controls daylight responsive controls; indicate that the area served by each control device does not exceeds 2,500 sf NA Identify sidelit and toplit daylight zones that are not provided with daylight sensing controls and the exception(s) that apply YES C405.2.4.1.1 Daylight responsive Indicate on plans the lighting load reduction A1.3 controls method (continuous dimming, or stepped dimming that provides at least two even steps between 0%-100%0 of rated power) YES C405.2.4.1 Daylight responsive Indicate that daylight sensing controls are A1.3 controls configured to completely shut off all controlled lights in the lighting zone YES C405.2.5 Additional controls - Identify spaces and lighting fixtures on plans A1.3 Specific application that require specific application lighting lighting controls controls per this section NA C405.2.5, Display and accent Indicate on plans that manual controls are Item 1 lighting provided that control display, accent lighting and display case lighting independently from both general area lighting and other lighting applications within the same space NA Indicate manual and automatic (occupant sensor or time switch) lighting control methods C405.2.5, Hotel/motel guest Indicate method of automatic control - Item 3 rooms vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5, Supplemental task Indicate method and location of manual and Item 1 lighting automatic shut-off control (occupant sensor or time switch) for supplemental task lighting, including under -shelf or under -cabinet lighting NA C405.2.5, Lighting equipment Indicate on plans that lighting equipment for Item 1 for sale or sale or demonstration are controlled demonstration independently from both general area lighting and other lighting applications within the same space NA Indicate manual and automatic (occupant sensor or time switch) lighting control methods NA C405.2.5, Lighting for non- Identify all eligible non -visual lighting Item 4 visual applications applications on plans; indicate that the area served by each control device does not exceeds 4,000 sf NA Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space Page 3110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA Indicate method of manual lighting control and applicable automatic lighting control C405.2.5, Means of egress Identify on plans egress fixtures that function Item 5 lighting as both normal and emergency means of egress illumination YES Provide calculation of lighting power density of total egress lighting If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods Indicate method of automatic shut-off control C405.4.1 Lighting control of Indicate that exempt interior lighting C405.4.2 exempt interior equipment and lighting located within spaces lighting that are eligible for a lighting power exemption are controlled independently from non-exempt and general area lighting NA C405.2.6 Exterior lighting For decorative exterior lighting, indicate on controls plans automatic daylight shut-off controls, or exception taken YES For exterior lighting that is not decorative, al.3 indicate on plans automatic daylight or time - switch shut-off controls and setback controls; or indicate exception taken NA For lighting requiring setback controls, include control sequence that reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA For building facade and landscape lighting, indicate control sequence for shut-off control is based on dawn -to -dusk and business opening/closing schedule; indicate whether automatic or time switch controls will be provided for this function NA C405.5.2 Lighting control of Indicate that exempt exterior lighting and exempt exterior lighting located within exterior areas/surfaces lighting that eligible for a lighting power exemption are controlled independently from non- exempt exterior lighting NA C405.5.4 Exterior gas -fired Indicate ignition system is a method other lighting appliances then continuously burning pilot light NA C405.2.7 Area controls - Indicate location(s) of master control Master control switch(es) intended to control multiple switches and circuit independent switches; circuit breaker may not power limit be used as a master control switch NA Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% ADDITIONAL EFFICIENCY CREDIT - ENHANCED INTERIOR LIGHTING CONTROLS Page 4110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C406.4 Enhanced digital To comply with additional efficiency credit, lighting controls indicate on plans that interior lighting fixtures are configured with all of the following control functions, as applicable: 1) Each fixture is individually addressed, or exception taken; 2) Fixtures are configured for continuous dimming; 3) No more than eight fixtures are controlled by a single daylight sensor; 4) In enclosed and open office areas, illumination levels of overhead general area lighting is configured to be individually adjusted by occupants Include calculations that demonstrate the total lighting power of all interior lighting fixtures configured with enhanced lighting controls is no less than 90% of the total interior lighting power for the area the enhanced lighting controls credit is being applied to INTERIOR LIGHTING POWER & EFFICACY YES C405.4.1 Total connected Include all luminaires in interior lighting A1.3 C405.4.2 interior lighting fixture schedule; indicate fixture types, lamps, power ballasts, and manufacturer's watts per fixture for the installed lamp NA Identify spaces eligible for lighting power exemption on plans and in WSEC interior lighting compliance reports; indicate the exception applied Identify lighting equipment eligible for lighting power exemption in fixture schedule and in WSEC interior lighting compliance reports; indicate the exception applied C405.1 Lighting in dwelling For all installed luminaires, include lamp type C405.1.1 units (multifamily) and number of lamps in lighting fixture schedule; for lamps that are not LED, T-8 or small diameter fluorescent, indicate efficacy of other lamp types is 65 lumens per watt or greater For all installed luminaires, indicate in lighting fixture schedule whether complying via lighting power density or by qualifying lamp type; if by lamp type, include number of lamps For all installed luminaires, indicate in lighting fixture schedule whether complying via lighting power density or by qualifying lamp type; if by lamp type, include number of lamps INTERIOR LIGHTING POWER CALCULATION - INDICATE COMPLIANCE PATH TAKEN NA C405.4.2.1 Building Area Demonstrate that total proposed wattage per Method building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans; provide WSEC exterior lighting compliance reports Page 5110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C405.4.2.2 Space -By -Space Demonstrate that total proposed wattage does Method not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas and areas with display, highlight and decorative lighting; provide WSEC exterior lighting compliance reports ADDITIONAL EFFICIENCY CREDITS - REDUCED INTERIOR LIGHTING POWER DENSITY C406.3.1 Reduced interior To comply with additional efficiency credit, C406.3.2 lighting power demonstrate that total connected interior density lighting wattage is 10% or 20% less than the total maximum allowed lighting wattage for the area the reduced lighting power credit is being applied to; indicate whether lighting power allowance is based on the building area method or space -by -space method; provide WSEC exterior lighting compliance reports C406.3 Reduced interior For project with dwelling units, to comply lighting power with additional efficiency credit indicate in density - dwelling lighting fixture schedule that lamps within unit lamp efficacy installed interior luminaires have an efficacy rating of at least 65 lumens per watt; include number of lamps and provide calculations that demonstrate at least 95% of lamps have this efficacy rating EXTERIOR LIGHTING POWER & EFFICACY YES C405.5.2 Total connected Include all luminaires in exterior lighting A1.3 exterior lighting fixture schedule; indicate fixture types, lamps, power ballasts, and manufacturer's watts per fixture for the installed lamp YES Identify exterior applications eligible for A1.3 lighting power exemption on plans and in WSEC exterior lighting compliance reports; indicate exception applied YES C405.5.3(1) Exterior lighting zone Indicate building exterior lighting zone as specified by the AHJ NA C405.5.1 Exterior building For building grounds fixtures rated at greater grounds lighting than 50 watts, indicate rated lamp efficacy (in lumens per watt) in fixture schedule EXTERIOR LIGHTING POWER CALCULATION YES C405.5.3 Tradable allowances Demonstrate that total proposed tradable surface wattage does not exceed maximum allowed tradable surface wattage (including base site allowance); identify locations of tradable surfaces on plans; provide WSEC exterior lighting compliance reports Page 6110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA LIGHTING ALTERATIONS Demonstrate that proposed wattage per non - tradable surface type does not exceed maximum allowed wattage per non -tradable surface type (including base site allowance remaining after tradable allowance calculation); identify locations of non -tradable surfaces on plans; provide WSEC exterior lighting compliance reports C503.6.1 Interior and parking Where _ 50% of existing luminaires in an garage lighting interior space or parking garage are replaced; fixture alterations indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed lighting wattage does not exceed maximum allowed per compliance path Where < 50% of existing luminaires in an interior space or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where _ 50% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in WSEC exterior lighting compliance reports; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in WSEC interior exterior compliance reports; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration C503.6.2 Interior lighting Where new wiring is installed to serve new wiring and circuiting interior luminaires and /or luminaires are alterations relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5) Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to a new circuit; indicate automatic lighting controls are provided (C405.2.6) Page 7/10 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com RECEPTACLES C503.6.3 Lighting panel Where a new interior and/or exterior lighting alterations panel is installed or an existing panel is moved (all new raceway and conductor wiring), indicate all applicable lighting controls requirements apply C503.6.4 Newly -created rooms Where interior space(s) is reconfigured (permanently installed walls or ceiling -height partitions) to create new enclosed spaces, indicate all applicable lighting controls requirements apply C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage C505.1 Change of interior Identify spaces on plans where the building space use area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) Indicate compliance method (building area or space -by -space); include all new and existing - to -remain luminaires in WSEC interior lighting compliance reports; indicate proposed lighting wattage does not exceed maximum allowed per compliance path C405.10 I Controlled I Identify all controlled and uncontrolled receptacles receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc Provide schedule that lists the number of controlled and uncontrolled receptacles in each space where controlled receptacles are required - classrooms, private offices, open office areas, conference rooms, copy rooms, break rooms and modular partitions/workstations Indicate on plans the method of automatic control for each controlled receptacle zone (occupant sensor or programmable time -of day control); indicate that each zone served by a single controller does not exceed 5,000 sf C405.2.5, Switched receptacles Indicate method of automatic off control of Item 2 in sleeping units all switched receptacles in sleeping units (vacancy or key card control) C503.6.6 Electrical receptacle Where new receptacles are added or replaced alerations within an alteration project that is 5,000 sf or larger, indicate receptacles are provided with automatic controls per C405.10, or exception taken MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION Page 8110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C405.6 Electrical Include electrical transformer schedule on transformers electrical plans; indicate transformer type, size, efficiency, or exception taken NA C405.11 Feeders and branch Provide documentation that demonstrates circuits maximum voltage drop across feeders and branch circuits does not exceed 5% C405.7 Dwelling unit Indicate on electrical plans that each dwelling electrical energy unit in Group R-2 has a separate electrical consumption energy meter C405.8 Electric motor Include all motors, including fractional hp efficiency motors, in electric motor schedule on electrical plans; indicate motor type, horsepower, rpm, rated efficiency, or exception applied C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculations that demonstrate average efficacy is not less than 35 lumens per watt For elevators that do not have an integral air conditioning system, indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more C405.9.2 Escalators and Indicate escalators comply with ASME moving walks At7.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (CX) C408.4 Scope of electrical Indicate that all electrical systems power and lighting (receptacles, transformers, motors, vertical systems and horizontal transportation) for which the commissioning WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned Where total building lighting load is > 20 kW, or where total lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception C405.13 Commissioning Indicate Cx requirements in plans and C408.1.1 requirements in specifications for all applicable electrical and C408.1.2 construction lighting control systems per C408 C408.1.4.2 documents C 103.6.3 Page 9110 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C408.1.2 Commissioning Include general summary of Cx plan per C408.1.2.1 requirements in C408.1.2 including: 1) Narrative description C408.1.4 construction of activities; 2) Responsibilities of the Cx C103.6.3 documents team; 3) Schedule of activities including verification of project close out documentation per C103.6; 4) Conflict of interest plan (if required) C408.1.2 Commissioning Include in general summary that a Cx project C408.1.4 requirements in report and Compliance Checklist (Figure C103.6.3 construction C408.1.4.1) shall be completed by the documents Certified Cx Professional and provided to the owner prior to the final electrical inspection C408.4.1 Functional Identify in plans and specifications the A0.0 performance testing intended operation of all equipment and criteria controls during all modes of operation, including interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION NA C103.6.3 Project close out Indicate in plans that project close out A0.0 documentation documentation is required including WSEC requirements lighting compliance reports that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities If "no" is selected for any question, provide explanation. Page 10/10