Loading...
REV1 APPROVED RESUB1 FIR2022-0032+Fire_Alarm_Plan+10.1.2024_12.50.50_PM+4534248Approved DFM aMris Burt South County Fire FIRDALE VILLAGE SHOPPING PLAZA 10-02-2024 RESUB 1 PLAN REVIEW NOTES: APPROVED DFM BURT GENERAL NOTES 1. ALL WALL MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, 2016 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES OR 6" FROM CEILING, WHICHEVER IS LOWER. FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 110CD. 2. ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC. 4. DO NOT DEVIATE FROM ANY CONDUIT OR WIRE RUNS SHOWN ON FLOORPLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER. EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING ETC. ARE A RESULT OF DEVIATIONS AND ARE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW NOR CLOSER THAN 3 FEET FROM AN AIR SUPPLY DIFFUSER. 6. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AHJ. 7. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL SHALL SUPERVISE THE ANNUNCIATOR PANEL, INITIATING AND INDICATING DEVICE CIRCUITS. 9. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 10. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15DB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A DB METER. 11. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12. INSTALLATION SHALL BE IN COMPLIANCE WITH NFPA, LOCAL, STATE, NEC AND CONTRACT DRAWINGS. VICINITY MAP FOREST 2a hPisn = WhirlyBalY' //h:S. cnetechnologyQ�1I s Hick'l an Park 23Whsi . ; s a \\ TJ- Max. s t 3 3 S ' vi e \\ s s S - z3etn sl sw 23nn ssw Q Madrona K-8 School0 N, 238th StSW GHosoonyi Korean Clerk's Office 3 F 2-h PI SW 's _ 1.m�s1 sW a 21-MSW 2�mn PI SW /rQ 21ahrsw jBu.rlington2..d 5 s F £ Firdale Ave, s •Edmonds, WA 98020 4 Dennys s Panera m„t� z.3rdwsw Brea 244m St SW UW Neighborhood o +; r N20tlhS Kruckeberg ! Botanic Garden Nwza3rer $ IlprelineClinic... Hzoxds i7i�e Home Depot Nw zoaea £ = Hw 209W9 N202n II Nw zolns Nw zm 6ls � Costco Wholesale � � NW 2p22,R i N291 s Nw 2aah s, Discount Tire _ N zoom s< Ec o Lake Park NW19Yh" A s HILLWOOD N199NS Nw 1 MelvinGSyre - f E £ Hwl9alha N1981h9 NW 19-St Elementary School0 ; King's Elementary School 1 0 � u Echo Elementary OND Sc / iH Spin Alley Bowling Center V NW 195th S[ N195N St Einstein Middle School0 King's Schools 0 2 N19519n' Dale Turner Famil YMC .� SHEET # FIREALARM SYSTEM EDMONDSy WA SHEET INDEX DESCRIPTION FA-01 SYSTEM INFORMATION FA-02 TYPICAL MOUNTING & WIRING DETAILS FA-03 CALCULATIONS FA-04 BASEMENT FA-05 FIRST FLOOR FA-06 SECOND FLOOR FA-07 RISER DIAGRAM WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE - ADDRESSABLE LOOP 2 CONDUCTOR #16 FPLP S STROBE CIRCUIT 2 CONDUCTOR #14 FPLP I INITIATION CIRCUIT 2 CONDUCTOR #18 FPLP T POWER SUPPLY TRIGGER 2 CONDUCTOR #14 FPLP B SBUS / ANNUNCIATOR 4 CONDUCTOR #18 FPLP CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA 2 CONDUCTOR 600V #12 AWG THHN/THWN .244 O.D. .0467 2 CONDUCTOR 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 2 CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL: CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/211 .12 SQUARE INCH 3/411 .21 SQUARE INCH 1" .34 SQUARE INCH 1 1/4" .60 SQUARE INCH 1 1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH SYMBOLS LEG E N D QUANTITY SYMBOL DESCRIPTION MODEL MFG. BACKBOX MOUNTING HEIGHT 1 FACP FIRE ALARM CONTROL 6700 SILENT KNIGHT PROVIDED 66" A.F.F. TO TOP PANEL 1 DOC DOCUMENT BOX SSU-00689 SPACE AGE PROVIDED 66" A.F.F. TO TOP ELECTRONICS 1 BPS REMOTE BOOSTER 5496 6A SILENT KNIGHT PROVIDED 66" A.F.F. TO TOP POWER SUPPLY 1 ANN ANNUNCIATOR REMOTE 5860R SILENT KNIGHT PROVIDED 66" A.F.F. TO TOP ANNUNCIATOR OUTDOOR (STI) SAFETY ___ L ENCL - ENCLOSURE STI-7500A TECHNOLOGY PROVIDED 66" A.F.F. TO TOP 1 AES AES RADIO AES 7707P AES PROVIDED 66" A.F.F. TO TOP COMMUNICATOR SMOKE DETECTOR 4S BOX W/1 G 10 O (ADDRESSABLE -PHOTO) SK-PHOTO-W SILENT KNIGHT MUD RING CEILING HEAT DETECTOR 4S BOX W/1 G 31 O (ADDRESSABLE -HEAT) SK-HEAT-W SILENT KNIGHT MUD RING CEILING MANUAL PULL STATION 4S BOX W/1 G 1 F (ADDRESSABLE) SKPULL SILENT KNIGHT MUD RING 48" A.F.F. TO CENTER CONTROL MODULE VERIFY LOCATION IN ___ OM (ADDRESSABLE) SK-CONTROL SILENT KNIGHT 4S BOX FIELD MONITOR MODULE VERIFY LOCATION IN ___ AIM (ADDRESSABLE) SK-MONITOR SILENT KNIGHT 4S BOX FIELD 110 HORN STROBE OUTDOOR VERIFY LOCATION IN 1 MWP (WALL MOUNT) P2RK SYSTEM SENSOR PROVIDED FIELD 15 HORN STROBE 22 o (CEILING MOUNT) PC2RL SYSTEM SENSOR 4S BOX CEILING ♦I�15 STROBE 23 i(�♦ (CEILING MOUNT) SCRL SYSTEM SENSOR 4S BOX CEILING ___ -NW� END OF LINE RESISTOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A ___ EX EXISTING DEVICE N/A N/A N/A N/A ___ N/A NOT APPLICABLE N/A N/A N/A N/A ___ N/A NOT APPLICABLE N/A N/A N/A N/A ___ N/A NOT APPLICABLE N/A N/A N/A N/A SCOPE OF WORK BUILDING DESCRIPTION NEW FIRE ALARM SYSTEM - INSTALL SILENT KNIGHT 6700 ADDRESSABLE FIRE BUILDING DESCRIPTION- EXISTING STRUCTURE, MULTIPLE TENANT OFFICES & ALARM CONTROL PANEL, AES RADIO COMMUNICATOR, 1 SMOKE DETECTOR, 25 RETAIL HEAT DETECTORS, 46 AUDIBLE AND VISUAL NOTIFICATION DEVICES IN SUITES AND RESTROOMS PER PLAN. OCCUPANCY CLASSIFICATION- B 9/28/2024 REVISION 4- ADDED DAYCARE TO SYSTEM. 9 SMOKE DETECTORS, 4 SPRINKLERED- NO HEAT DETECTORS, 4 STROBES AND 3 CEILING HORN STROBES. W � � � N � � M N � y 05 00. 050 U. G011111111 oo RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0032 Q N Q n W CD o Cl)Z W o q-Qm U) O J Q �U)Q� W U) Q Q E Z Q J_ O LLIid� J W LL Q 0 IL PREPARER: ALAN HETLAND NICET CERTIFICATION: # 146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 3 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: SYSTEM INFORMATION DATE: 9/28/2024 \ SHEET: FA-01 / SK-PULL-SA ADDRESSABLE PULL STATION FIRE FULL 1 DOWN NI �I HQ� E"Ywell Il o� SLC LOOP IN r (+) FROM PREVIOUS L DEVICE (-) o� (-) SLC LOOP _ OUT T❑ NEXT (+) DEVICE i§Mffl� SK-PHOTO-W FIGURE 3: FEATURES OF THE PHOTO DETECTOR Magnet I—. VLED Base Alignment Notch j gnet Test Marker LED C2021-00 FIGURE 2. WIRING DIAGRAM: Remote CAUTION: Do not loop wire under Annunciator terminal 1 or 2. Break wire run to + - supervise connections. a ac m O o o O o0 Uo m� o REAR VIEW (+) NOTE: THE MANUAL PULL STATION CAN BE FLUSH MOUNTED ON A SINGLE GANG DEEP BOX OR CAN BE SURFACE MOUNTED ON A SB-I/0 OR SB-10 BOX. CLASS A OPTIONAL WIRING C0129-10 FIGURE 1. ROTARY ADDRESS SWITCHES: 56 10 56 3 12 3 2 13 2 015 0 C0162-00 CEILING MOUNT STROBE & HORN STROBE FIGURE 6. WIRING TERMINALS, SHORTING SPRING, AND STRIP GUIDE �Y Shorting Spring -WIRING TERMINALS 1. Negative (-). Line in and out 2. Positive (+). Line in and out 3. Positive (+). Line in and out Strip Guide A0475-01 SYSTEM WIRING The 2-wire horn strobe, chime strobe and strobe only require two wires for power and supervision. (See Figure 7.) Please consult your FACP manufac- turer or power supply manufacturer for specific wiring configurations and special cases FIGURE 7. 2-WIRE CIRCUIT INPUT FROM UTPUT FACP OR 4TNO" EXTPRIOEVICE DEVICEWM + EOL + A0367-02 FIGURE 8. MOUNTING Locking button A0492-01 A0574-00 7707P-88 DETAIL VIEW HORN/STROBE, STROBE & MANUAL PULL STATION MOUNTING DETAILS TYPICAL HORN/STROBE -- 80" A.F.F. TO BOTTOM MANUAL PULL STATION 48" A.F.F. TO CENTER 10'. 4S DEEP BOX �l l l I I ~ EMT IF REQUIRED I�1G BACKBOX TYPICAL MOUNTING AND WIRING DETAILS HONEYWELL SILENT KNIGHT 6700 P2RK OUTDOOR HORN STROBE r. Wall -Mount Horn Strobe with Plastic Weatherproof Back Box FIGURE 4. WIRING 2-WIRE PRODUCTS INPU- FROA FACP OR PRIOI DEVI( JTPUT =XT =VICE R EOL A0367-01 11�111�11�111�11��11 I 1AodN6700 f7M0M11ii LP" CONUM z� U�o N 1.4 `r' O 06 00. Z 4 ON RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES !� : DEPARTMENT 1--1 FIR2022-0032 ig Q �:=4 L W (D o U)zwo >�Q001)) cnowQ z �U)Q� �w�U Q(D -Q Z �Qoz � 2iQ J O �0) WQ w w LL Q t� L.L PREPARER: ALAN HETLAND NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 4 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: TYPICAL MOUNTING & WIRING DATE: 9/28/2024 SHEET: FA-02 Honeywell SILENT' Irn GHT Device Type IntelliKnight 6700 Battery Calculation Secondary Power Source Requirements StandbySecondary Qty Current Draw Tota I Qty I Current Draw Tota 1. Control Panel 6700 Control Panel 1 1 IxI 0.165000 1=1 0.165000 1 1 IxI 0.310000 1=1 0.310000 2. Addressable SLC Devices SK-PHOTO (-T) x 0.000300 = x 0.000300 = SK-PHOTO-W (-T) 10 x 0.000200 = 0.002000 10 x 0.000450 = 0.004500 SK-HEAT(-HT) (-ROR) x 0.000300 = x 0.000300 = SK-HEAT-W(HT) (ROR) 31 x 0.000200 = 0.006200 31 x 0.000450 = 0.013950 SK-BEAM x 0.002000 = x 0.002000 = SK-BEAM-T x 0.002000 = x 0.002000 = SK-DUCT x 0.000300 = x 0.000300 = SK-ACCLIMATE x 0.000300 = x 0.000300 = SK-CONTROL x 0.000375 = x 0.000375 = SK-MONITOR x 0.000375 = x 0.000375 = SK-MINIMON x 0.000375 = x 0.000375 = SK-PULL-SA 1 x 0.000375 = 0.000375 1 x 0.000375 = 0.000375 SK-PULL-DA x 0.000375 = x 0.000375 = SK-MONITOR-2 x 0.000750 = x 0.000750 = SK-MON-10 x 0.003500 = x 0.003500 = SK-RELAY-6 x 0.001450 = x 0.001450 = SK-CONTROL-6 x 0.002250 = x 0.002250 = SK-RELAY x 0.000255 = x 0.000255 = SK-RELAYMON-2 x 0.001300 = x 0.024000 = SK-ZONE x 0.000270 = x 0.000270 = SK-ZONE-6 i IxI0.002000 jxj 0.002000 1=1 SK-FIRE-CO I IxI0.000300 IxI 0.007200 1=1 3. SLC Accessory Bases B200S x 0.000300 = x 0.000300 = B20OS-LF x 0.000300 = x 0.000300 = B200SR x 0.000300 = x 0.000300 = B200SR-LF x 0.000300 = x 0.000300 = B224RB x 0.000500 = x 0.000500 = RTS151 x 0.000000 = x 0.007500 = RTS151 KEY x 0.000000 IxI 0.007500 = RA100Z 1XI 0.000000 1XI 0.010000 = 4. SLC Isolator Devices SK-ISO x 0.000450 = x 0.000450 = ISO-6 IxI 0.002700 IxI 0.102000 = B224B1 IxI 0.000500 IxI 0.000500 = 5. Auxiliary Power Draw - SLC Devices SK-CONTROL (Aux. Power) x 0.001700 = x 0.007000 = SK-CONTROL-6 (Aux. Power) x 0.008000 = x 0.020000 = SK-ZONE (Aux. Power) x 0.012000 = x 0.090000 = SK-ZONE-6 (Aux. Power) x 0.050000 = x 0.270000 = B200S (Aux. Power) x 0.000500 = x 0.035000 = B20OS-LF (Aux. Power) x 0.000550 = x 0.140000 = B200SR (Aux. Power) IxI 0.000500 = I x 0.035000 = B200SR-LF (Aux. Power) 1XI 0.001000 = I X1 0.125000 = 6. Accessory Modules 5860 1 x 0.020000 = 0.020000 1 x 0.025000 = 0.025000 5824 x 0.045000 = x 0.045000 = 5496 x 0.010000 = x 0.010000 = 5895XL x 0.010000 = x 0.010000 = 6855 x 0.020000 = x 0.025000 = 6860 x 0.025000 = x 0.050000 = 5865-4 x 0.035000 = x 0.145000 = 5865-3 x 0.035000 = x 0.145000 = 5880 x 0.035000 = x 0.200000 = 5883 x 0.000000 = x 0.220000 = SK-IP-2 x 0.093000 = x 0.136000 = SK-IP-2UD x 0.098000 = x 0.155000 = CELL -MOD x 0.055000 = x 0.100000 = CELL-CAB-SK x 0.055000 = x 0.100000 = WSK-WGI Aux. Power x 0.040000 = x 0.040000 = SLC Power x 0.024000 = x 0.024000 = SK-NIC x 0.021000 = x 0.021000 = SK-NIC-KIT x 0.021000 = x 0.021000 = SK-FSL x 0.079000 = x 0.079000 = SK-FML x 0.053000 = x 0.053000 = SK-FFT x 0.120000 = x 0.230000 = 7. Miscellaneous Devices Conventional Detectors x 0.000000 = x 0.000000 = Miscellaneous Device 1 x 0.000000 = x 0.000000 = Miscellaneous Device 2 x 0.000000 = x 0.000000 = Miscellaneous Device 3 x 0.000000 = x 0.000000 = Miscellaneous Device 4 x 0.000000 = x 0.000000 = Miscellaneous Device 5 1 1XI0.000000 1 = I I 1XI0.000000 1=1 8. Notification Appliance Circuits NAC 1 1 1 1 0.000000 1 = 0.573000 = 0.573000 NAC 2 0.000000 = 0.630000 = 0.630000 Total Standby Load 0.193575 Total Alarm Load 1.556825 Honeywell lntelliKnight 6700 Circuit Detail Device Qty �rm Draw I Total I Qty Draw I Total 1 . - - • ©© 1111111 � 1111111 ©© 11.1111 � 1� 1111 • - - • ©© 1111111 � 1111111 ©© 11� III � 1 111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 Total Standby Load Device Qty �rm Draw I Total I Qty h Draw I Total 1 . - - • ©© 1 111111 � 1 111111 ©© 1 1.1111 � 1 :1111 • - - • �© 1111111 � 1111111 �© 11� 111 � 1 .�111 • - - • ©© 1111111 � 1111111 ©© 1 � 111 � 1 :•111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 _© 1111111 �-_© 1111111 Total Standby Load Honeywell ®S WGIFIT IntelliKnight 6700 EOL Voltage Drop Starting Voltage 20.4 Volts Minimum Voltage @ EOL 16 Volts Voltage Drop Warning % 10.00% Current Draw Wire Type Resistance Length Actual Resistance Voltage @ EOL Percent Drop Circuit Name Amps AWG Ohms/1000 ft. Feet (One Way) Ohms Volts Percent NAC 1 0.573 #14 Solid 3.07 145 0.89 19.89 2.50% NAC 2 1 0.630 1#14 Solid 1 3.07 190 1 1.17 1 19.67 3.60% Resistance Table Wire Type Resitance AWG Ohms/1000 ft. #10 Solid 1.21 #10 Stranded 1.24 #12 Solid 1.93 #12 Stranded 1.98 #14 Solid 3.07 #14 Stranded 3.14 #16 Solid 4.89 #16 Stranded 4.99 #18 Solid 7.77 #18 Stranded 7.95 Note: Al Resistance values are taken from Table 8 Conductor Properties of the NFPA70 National Electrical Code. All Values are for Direct Current Resistance at 75-C (167-F). Honeywell ®SILENT' WCHT IntelliKnight 6700 Battery Calculation Note 1: You are fully responsible for verifying these calculations. Note 2: Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet 24 Hours Standby Load Current 0.19358 Amps x 24 = 4.646 AH -. -. 5 Minutes Alarm Load Current (Amps) 1.55683 Amps x 0.084 = 0.131 AH Total Current Load 4.777 AH Multiply by the Derating Factor 1 1.2 1 = x 1.20 Total Ampere Hours Required 5.73 AH Recommended Batteries: BAT-1270 - 7AH Batteries Battery Check The batteries can be charged by the 6700 Charger. The batteries can be housed in the 6700 Cabinet. Current Draw Check Circuit#1 current is within the limitations of the circuit. Circuit#2 current is within the limitations of the circuit. 6700 Control Panel: The output current is within the panel's limitations. RECOMMENDED BATTERIES 7AH Notification Appliance Circuit Detail PROJECT: Panel: Location: Date: FIRDALE VILLAGE BPS1 Model: Silent Knight 5496 Elec Rm 2nd Floor September 26, 2024 Wire Resistance CURRENT TOTAL AMPS= 3.07 2.59 4 PC2RL30cd Horn Strc 90 360 EW PC2RL75cd Horn Strc V1111111111 143 1 P2RK115cd Horn Stro 218 218 W4 SCRL15cd Strobe 164 DEVICES= 10 TOTAL mA= 885 14 165 23.10 885 Total Wire Resistance ( R) (WL * 2) * (R/ft) 1.01 Total Device Load, Amps (1) (Total Cct Load) 0.89 Voltage Drop ( E) (E= I ` R) 0.90 EOL Voltage 24 - E) F 23.10 ;TireZ 3 PC2RL75cd Horn Strc 143 429 2 SCRL15cd Strobe 82 1 SCRL30cd Strobe 63 63 0 Unused 0 0 DEVICES= 6 TOTAL mA= 574 14 195 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) 1 PC2RL115cd Horn Str 3 SCRL15cd Strobe ■ 0 Unused 0 Unused ' DEVICES= 4 187 187 0 0 TOTAL mA= Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop ( E) 23.80 574 (WL *2)*(R/ft) 1.20 (Total Cct Load) 0.57 (E= I * R) 0.69 310 14 235 23.90 (WL *2)*(R/ft) (Total Cct Load) 6 SCRL15cd Strobe 41 246 Horn Strobe 0 Unused 0 0 0 Ulm 310 1.44 0.31 0.45 DEVICES= 10 TOTAL mA= 818 14 105 23.92 818 Total Wire Resistance ( R ) (WL * 2) * (R/ft) 0.64 otal Device Load, Amps (1) otaI Cct Load) Voltage Drop ( E) (E= I * R) 0.53 EOL Voltage' 4 - E))l 23.47 FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: FIRDALE VILLAGE Panel: SILENT KNIGHT 5496 6A Date: March 28, 2022 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 160 160 0 160 160 0 A TOTAL FIRE ALARM POWER SUPPLY 160 160 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / mA) 0 2587 Total(A)= 160 Total(B)= 2747 CALCULATION D Total current ratings of all devices in system (line A + line B + line C) 160 2747 E Total current ratings converted to amperes (line D x .001) 0.16 2.747 F Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 G Multiply lines E and F Total Standby AH 3.84 H Alarm sounding period in hours (15 mins = 0.25 hours) 0.25 1 Multiply lines E and H Total Alarm AH 0.68675 J Add lines G and I Total Standby and Alarm AH 4.52675 K Multiply line J by 1.2 (20% extra insurance to meet desired performance) 5.4321 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 RECOMMENDED BATTERIES 7AH W � � � M N � O M� h 000a �II � RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0032 N Q G J W 0- (D O � Z W o 0 Cn0 JQ � U)Q WSW I� Q Q LL 0 Q J_ O >�� 0 W W W LL. 0 LL PREPARER: ALAN HETLAND NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 A�HEATS4 DRR'S AND 9/26/2024H9619 PAGE: CALCULATIONS CALCULATIONS DATE: 9/28/2024 SHEET: FA-03 ME BASEMENT SCALE: 3/1611=11 z1.4 U�o O � � N � O i yr = 000a as on LL. RESUB [=4 Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0032 Q N Q W C� o �zwo <m Cn0JQ �U)Lu Q�: �Lu�cn QQ�z Q J_ O W dF) r J W r) LL PREPARER: ALAN HETLAND NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 —j PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 4 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: BASEMENT DATE: 9/28/2024 SHEET: FA-04 r GQV 9 0 501313 1l5 N5.3 0�'05 i 0o N5 ,b.% Sp3i FIRST FLOOR SCALE: 3/16"=1' PREV. APPROVED PLAN 6/14/2022 AFM KFITTERER PERMIT #FIR2022-0043 V z1.4 U�o O � � N � O �i y■r = a O0� as on" RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0032 Q N Q ui C� o U)zLuCN �l >Q� CnOJQ �U)Q� �w�lv� QQLLz Q J_ O LJJ i � J w � L.L Q 0 LL b PREPARER: ALAN HETLAND NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 —j PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 4 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: FIRST FLOOR DATE: 9/28/2024 SHEET: FA-05 ffLOOz f�ELO V TO 1ST FLOOR DAYCARE S033 TO B H^o DOWN DOWN SECOND FLOOR SCALE: 3/16"=1' PREY. APPROVED PLAN 6/14/2022 AFM KFITTERER PERMIT #F I R2022-0043 RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0032 Q N Q W CD U) Z Cn O G Cn W J J Q J_ LLl i ()L w LL Q 0 LL LLI Q J Q LL 0 dF) 0 NO 00 Z O 2 0 PREPARER: ALAN HETLAND • m ff ill nAl a M V NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 4 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: SECOND FLOOR DATE: 9/28/2024 SHEET: FA-06 SO41 D SO40 D S039 D S038 D S037 D S036 D S035 D S034 2ND FLOOR 1-16-6 H6-8 H6-9 1-16-10 1-16-1 H6-2 1-16-3 1-16-4 1-16-5 H6-7 75CD 75CD 75CD 75CD S 15CD S 15CD S 75CD S 15CD S 15CD S S 15CD $ S S H6 ♦rI�♦ZI�♦zI�♦ZI�♦ZI ♦(�� O O O E O H6 I♦ I♦ I♦ I♦ I♦ I♦ H5-3 1-15-1 H5-2 115CD 1-15-4 S032 D S033 D S 15CD $ 15CD $ $ 1,5CD i l H5 ♦II�♦II ♦Z�..._ EOL 1-14-2 H4-5 1-14-6 1-14-1 75CD 1-14-3 1-14-4 75CD 75CD S 15CD S S 30CD S 15CD S S 17 H4 ;I; O �(�♦�-�(�♦ O O EOL S031 D S030 D S029 D S028 D S027 D S026 D S025 D S024 D S023 D S022 D S021 D S020 D S019 D S018 D S017 D S016 D S015 D S014 D M001 D (� 1-13-2 1-13-3 H3-4 H3-5 1-13-9 1-13-10 1-13-1 30CD 75CD 115CD 30CD H3-6 1-13-7 1-13-8 30CD 30CD S 15CD S S S �WP S S 15CD S 15CD S 75CD S S H�♦�� fr l ♦zI♦04 EOL `i B I �♦ v v y"Z v �V♦ �V1�V♦ O O H3 1ST FLOOR BASEMENT Doc. FACP BPS1 BOX 6700 5496 ELEC RM—/ fM —7 S013 D S012 D S011 D S010 D S009 D S008 D S007 D S006 D S005 D S004 D S003 D S002 D S001 AES RADIO 110 VAC, DEDICATED (BY OTHERS) 1-11-1 1-11-3 1-11-5 H1-6 1-11-8 30CD 1-11-2 30CD H14 30CD 30CD H1-7 30CD S $ 15CD $ $ 15CD $ $ $ 15CD $ H1 O EOL ♦Ii O ♦z� ♦a� I ♦ H1 1-12-1 1-12-3 H2-6 1-12-8 30CD 1-12-2 30CD H2-4 1-12-5 75CD H2-7 75CD $ S 15CD $ S 15CD S 15CD $ 7 $ 15CD $ H2 ♦z� ° ♦a��♦ate O ♦�� EOL v ♦v♦ ♦ ♦ ♦ ♦ I ♦ H2 RISER DIAGRAM w � Z � � O 1.4 O � � N � O V rA 000a L RESUB Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES J DEPARTMENT FIR2022-0032 N 5 Q L W � �V O Z W 0 Q rn C)OJQ �U)Q� �W�u QQLLz Q J_ O W dF W W LL F� LL �J PREPARER: ALAN HETLAND NICET CERTIFICATION: *146032 FIRE ALARM SYSTEMS LEVEL IV EXPIRATION DATE: 11/01/2026 PROJECT MANAGER: Todd Hetland SCALE: As Noted NO. REVISION DATE - SHOP DRAWINGS 12/20/2021 FLOORPLAN 1 3/28/2022 CORRECTION DELETE PULLS, ADD 2 6/10/2022 HEATS 3 ADD DAYCARE 7/16/2024 ADD HEATS 4 DAYCARE RR'S AND 9/26/2024 HS SUITE #9619 PAGE: RISER DIAGRAM DATE: 9/28/2024 SHEET: FA-07