APPROVED FIR2024-0096+Fire_Sprinkler_Plan+10.1.2024_10.37.36_AM+4533670Q SCOPE OF WORK 1. NEW GP56 & DS56 ATTIC HEADS TO BE INSTALLED ALONG WITH FlFR56 STANDARD SPRAY UPRIGHTS TO ACCOMODATE ATTIC HEAD BLINDSPOTS. GENERAL FIRE PROTECTION NOTES 1. THE FIRE SPRINKLER SYSTEM SHALL BE DESIGNED, INSTALLED, AND TESTED IN ACCORDANCE WITH NFPA-13 (2019) AND THE AUTHORITY HAVING JURISDICTION. 2. ALL MATERIAL SHALL BE UL LISTED, FM APPROVED, OR AHJ APPROVED FOR FIRE PROTECTION AND CONFORM TO NFPA-13 (2019). 3. WHERE SUBJECT TO FREEZING CONDITIONS, IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEATING ADEQUATE TO PREVENT THE FREEZING OF WATER -FILLED PIPE THROUGHOUT AREAS, WHERE WET -PIPE FIRE SPRINKLER SYSTEMS ARE INSTALLED; INCLUDING ENCLOSURES FOR DRY PIPE, PREACTION, AND DELUGE FIRE SPRINKLER SYSTEMS AND ALL OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 4. THE FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM. 5. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING, OR PATCHING SHALL BE BY OTHERS. 6. NEW AND RELOCATED UPRIGHT FIRE SPRINKLER HEADS SHALL BE INSTALLED ON 1" SCHEDULE 40 ARMOVERS. 7. FIRE SPRINKLER HEADS HAVE BEEN ADDED AND RELOCATED TO ACCOMMODATE TENANT IMPROVEMENTS. AREAS OUTSIDE THE SCOPE OF WORK AND/OR NOT IN CONTRACT SHALL REMAIN AS IS. 8. THE OWNER RESPONSIBLE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-25 (LATEST EDITION). THIS WORK SHALL BE DONE BY QUALIFIED PERSONNEL STARTING AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY THAT DESIGNED AND INSTALLED THIS SYSTEM IS THE BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING SERVICING, AND MAINTENANCE OF THIS SYSTEM(S). DESIGN CRITERIA ATTIC OCCUPANCY HAZARD CLASSIFICIATION SYSTEM TYPE: SPRINKLER TYPE: DESIGN DENSITY: DESIGN AREA: K-FACTOR: MAX SPRINKLER HEAD COVERAGE: HOSE ALLOWANCE: LIGHT HAZARD DRY QUICK RESPONSE SPECIFIC COVERAGE 0.127 GPM/SQFT 406 SQFT MIN. 5.6K 6 FT X 30 FT 100 GPM WATER SUPPLY INFORMATION STATIC PRESSURE: 102.69 PSI RESIDUAL PRESSURE: 97.73 PSI FLOW: 1421 GPM LOCATION: 21600 Hwy 99 SOURCE OF INFORMATION: City of Edmonds TEST DATE: 03/15/2024 ABBREVIATIONS AND TERMS AFF ABOVE FINISHED FLOOR HSW HORIZONTAL SIDEWALL SPRINKLER AHJ AUTHORITY HAVING JURISDICTION ITV INSPECTORS TEST VALVE ATR ALL THREAD ROD LH LIGHT HAZARD AUX AUXILIARY N/A NOT APPLICABLE BBV BUTTERBALL VALVE N.C. NORMALLY CLOSED BFP BACKFLOW PREVENTER N.O. NORMALLY OPEN BLR BRANCHLINE RESTRAINT NAS NO AUTOMATIC SPRINKLER BFV BUTTERFLY VALVE NIC NOT IN CONTRACT BOD BOTTOM OF DECK NPT NATIONAL PIPE THREAD BTS BOTTOM OF STEEL NST NATIONAL STANDARD THREAD CR CONCENTRIC REDUCER NTS NOT TO SCALE CLG CEILING OH1 ORDINARY HAZARD GROUP 1 CMDA CONTROL MODE DENSITY AREA OH2 ORDINARY HAZARD GROUP 2 CMSA CONTROL MODE SPECIFIC APPLICATION OS&Y OUTSIDE SCREW AND YOKE CNC CONCEALED PxP/PBE PLAIN BOTH ENDS COJ CUT ON JOB PND PENDENT CRR CORROSION RESISTANCE RATIO POC POINT OF CONNECTION CV CHECK VALVE PRV PRESSURE REDUCING VALVE DIA DIAMETER QR QUICK RESPONSE DN DOWN RES RESIDENTIAL DR DROP RN RISER NIPPLE EC EXTENDED COVERAGE RPBFP REDUCED PRESSURE BACKFLOW PREVENTER EH1 EXTRA HAZARD GROUP 1 RU/UP RISE UP EH2 EXTRA HAZARD GROUP 2 SP SPRIG ESC ESCUTCHEON SR STANDARD RESPONSE ESFR EARLY SUPPRESSION FAST RESPONSE SS STANDARD SPRAY FCA FLOOR CONTROL ASSEMBLY STZ STORZ CONNECTION FDC FIRE DEPARTMENT CONNECTION TS TAMPER SWITCH FIR FAST RESPONSE TxP THREAD x PLAIN FS FLOW SWITCH TxT/TBE THREAD BOTH ENDS FSP FIRE STANDPIPE TOE THREAD ONE END GxP GROOVE x PLAIN ENDS TOS TOP OF STEEL GxT GROOVE x THREAD ENDS TYP TYPICAL GxG/GBE GROOVE BOTH ENDS U.N.O. UNLESS NOTED OTHERWISE GALV GALVANIZED UPR/U UPRIGHT GOE GROOVE ONE END VSW VERTICAL SIDEWALL SYMBOL LEGEND NEW FIRE SPRINKLER PIPING EXISTING FIRE SPRINKLER PIPING - FLEXIBLE SPRINKLER DROP HANGER TRAPEZE HANGER [X J LATERAL BRACE (PERPENDICULAR TO PIPE) /--' LONGITUDINAL BRACE (PARALLEL TO PIPE) RISER BRACE BRANCH LINE RESTRAINT MIr. &' (200 rrn) top of aeflector above bottom of *0 ctvtair DEMO FIRE SPRINKLER EXISTING FIRE SPRINKLER Ql- RELOCATE FIRE SPRINKLER Q' ADD FIRE SPRINKLER pQ` QUICK RESPONSE SPRINKLER UPGRADE /P PLUGGED OUTLET CAP PIPE Model DS56 Min. 30' 1762 mrr) to max.4T (1067 mm) -} horllzontaly from draft cwaln of wall to de4lec*ar Min. T (230 rrfn) to max. 1 Y (330 mm) top of delector to roof deck Model GP56 Min. 9" (230 mm) to max, 13" (330 mm) top of deflector to roof deck Seismic calculations were reviewed with TOLBrace Program and confirmed to remain with maximum load provided. Approved DFM Cilvis'Burt South County Fire Date: 10/15/2024 10-15-2024 PLAN REVIEW NOTES: APPROVED - COMMENTS: 1. SEE COMMENTS REGARDING HYDRUALIC PLATE ON SHEET F04. 2. AN AIR TEST WILL BE REQUIRED PRIOR TO FINAL. DFM BURT Riser Detail for Attic 1" = 1'-0" MCKIINSTRY STANDARD CLARIFIES THE USE OF 20OF HEADS THROUGHOUT TO MINIMIZE HEAD TYPES AND INSTALLATION TIME. TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E_T•N 21600 Hwy 99 Phone: Powering BusinessWoddwrde Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace 1 Fig.1001 Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCOFIG IN E T Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 112 x 3-1/2 (13 x 89 mm) Dual Lag /C­ Bolts Perpendicular to Beam - TOLCO Type Fig 906Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) Maximum Load 360lbs (163 kg) Brace Identification on Plans 4" Lat-ATTIC Prying Factor N/A Brace Type Lateral [X] Longitudinal [ ] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4" (100 mm) Sch. 10 40 ft (12.2 m) 40 ft (12.2 m) 11.78 Ib/ft (17.53 kg/m) 471 lbs (214 kg) 1" (25 mm) Sch. 40 10 ft (3 m) 10 ft (3 m) 2.05 lb/ft (3.05 kg/m) 120 lbs (9 kg) Subtotal Weight 491 lbs (223 kg) Wp (incl. 15%) 565 lbs (256 kg) Main Size 4" Type/Sch. Sch. 10 Spacing (ft) 40 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 340lbs (154 kg) 769 lb (348 kg) 11 ULBrace- version ul use of rOLBrace - is subject to terms ana conanions per the ena user ucense agreement SPRINKLER SCHEDULE ATTIC COMPREHENSIVE QTY DESCRIPTION COLOR MFG MODEL SIN K-FCTR THIRD TEMP O 3 Reliable 1/2 Ordinary Upright Quick Response BRONZE Reliable F1 FR56 RA1425 5.6 1/2" 200 OF 0 133 Reliable Light Attic -Single Direction Quick Response BRONZE Reliable DS56 RA5625 5.6 1/2" 212 OF 0 12 Reliable Light Upright Quick Response BRONZE Reliable GP56 RA5695 5.6 1/2" 212 OF 4: 148 Total No. of Sprinklers: 148 Level 2 w lo6 10'-6" V TIE INTO EXISTING =S FROM WET SYSTEM. TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E:t•N 21600 Hwy 99 Phone: PowenngBusiness woddwe Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTm Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace ill Fig. 4L Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOn" components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 _ Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 980 _ 0 BRACE PIPE Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 1/2 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 TOLCO FIG. 4L Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) Maximum Load 360 lbs (163 kg) Brace Identification on Plans 4° Long Prying Factor N/A Brace Type Lateral [ ] Longitudinal [X] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4" (107 1 Sch.10 40 ft (12.2 m) 40 ft (12.2 m) 111.78 Ib/ft (17.53 kg/m) 1471 lbs (214 kg) Subtotal Weight 471 lbs (214 kg) Wp (incl. 15%) 542 lbs (246 kg) Main Size Type/Sch. 4" Sch. 10 Spacing (ft) 40 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 327lbs (148 kg) N/A tTOLbrace'"' Version B) Use of TOLBrace'" is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Bracing Calculations V8.9.137 Contractor: Project Address: Kruger Medical Building Address: E:t•N 21600 Hwy 99 Phone: PowenngBusiness Woddwde Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace 1 Fig.1001 Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please - Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCOFIG 9EU (INNERS.-Iiii- ATTAENNENT 9tACf PIPE Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 112 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) Maximum Load 360 lbs (163 kg) Brace Identification on Plans 6" LAT-ATTIC Prying Factor N/A Brace Type Lateral [X] Longitudinal [ ] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) C = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6" (150 mm) Sch. 10 10 ft (3 m) 10 ft (3 m) 1 23.03 Ib/ft (34.27 kg/m) 230 Ibs (104 kg) Subtotal Weight 230lbs (104 kg) Wp (incl. 15%) 264 Ibs (120 kg) Main Size Type/Sch. 61. Sch. 10 Spacing (ft) 10 Total (Fpw) Maximum Fpw per 9.3.6.5.2 (if applicable) 159lbs (72 kg) 4039 Ib (1832 kg) tTULBrace'"' Version 6) Use of TOLBrace "" is subject to terms and conditions per the end user license agreement EVERYTHING BEYOND 6" VIC B'FLY VALVE IS NITHIN PHASE 2 SCOPE OF WORK. Level1� TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E:t•N 21600 Hwy 99 Phone: PowenngBusiness ftnmde Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTm Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace ill Fig.1001 Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOn" components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 1/2 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 , Diameter 1/2in. (13 mm) { Length 3-1/2in. (89 mm) Maximum Load 360 lbs (163 kg) .":`1'�°.li�"R Brace Identification on Plans 2.5" Lat- ATTIC Prying Factor N/A Brace Type Lateral [XI Longitudinal [ ] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.6028 Diameter Type I Length Total Length Weight Per Unit Length Total Weight 775765 mm) Sch. 10 40 ft (12.2 m) 40 ft (12.2 m) 5.89 Ib/ft (8.77 kg/m) Ill 236 Ibs (107 kg) 1" (25 mm) Sch. 40 1 10 ft (3 m) 1 10 ft (3 m) 12.05 Ib/ft (3.05 kg/m) 120 lbs (9 kg) Subtotal Weight 256 Ibs (116 kg) Wp (incl. 15%) 2941bs (134 kg) Main Size 2.5" Type/Sch. Sch. 10 Spacing (ft) 40 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 177lbs (80 kg) 301 Ib (136 kg) tTOLISrace'"' Version Bl Use of TOLBrace'" is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E:t•N 21600 Hwy 99 Phone: PowenngBusiness Woddwde Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace 1 Fig. 4L Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOn components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 980 0 BRACE PIPE Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 112 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 -0 TOLCO FIG. 4L Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) g # Maximum Load 360 lbs (163 kg) Brace Identification on Plans 6" LONG -ATTIC Prying Factor N/A Brace Type Lateral [ ] Longitudinal [X] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6" (150 mm) Sch. 10 10 ft (3 m) 10 ft (3 m) 23.03 Ib/ft (34.27 kg/m) 230 Ibs (104 kg) Subtotal Weight 230lbs (104 kg) Wp (incl. 15%) 264 Ibs (120 kg) Main Size Type/Sch. 61. Sch. 10 Spacing (ft) 10 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 159lbs (72 kg) N/A tTULBrace'"' Version 61 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED: COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEPA AIR SUPPLY SYSTEM CONTROL VALVE AIR SUPPLY Tk%J1/2 (NORMALLY PRESSURE OPEN) INCH NPT CONNECTION GAUGE SYSTEM LOW BODY FOR SYSTEM WATER DRAIN VALVL AIR SUPPLY SUPPLY (NORMALLY PRESSURE CLOSED) 1 INCH NPT GAUGE CONNECTION / AUTOMATIC FOR LOCAL ) GROOVED DRAIN VALVL SPRINKLER COUPLING tit �- OR FLANGE ll 1f2 INCH NPT DRIP FUNNEL ADAPTER �, CONNECTION FOR OPTIONAL MAIN ACCELERATOP. DRAIN VALVE ALARM INORMALLY 2 INCH NPT TEST VALVE 1.1/4 INCH NPT CLOSED) CONNECTION g INCH (.DN150) SYSTEM (NORMALLY 3r4 INCH NPT WATERFLOW CONNECTION CLOSED) P E TO DRAIN MODEL DPV-1 SHUT-OFF VALVE CONNECTION TO DRAIN ABM DRY PIPE VALVE FOR WATER SWITCH (GxG SHOWN.){NORMALLY OPEN) MOTOR ALARM FIGURE 5 - PART 1 OF 3 6 INCH (DN150) MODEL DPV-1 DRY PIPE VALVE PRE -TRIMMED ASSEMBLY Use of TOLBrace "" is subject to terms and conditions per the end user license agreement Swedish Heart & Vascular - Edmonds... VICINITY MAP TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E_t•N 21600 Hwy 99 Phone: PoweongBusiness Woddwide Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTm Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace 1 Fig. 4L Clamp 2000 lbs (907 kg) 2074 lbs (941 kg) Fig.980 1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOn components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG 980 _ 0 BRACE PIPE Fastener Information Orientation to Connecting Surface NFPA Type H Fastener 1/2 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 - TOLCO FIG 4L Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) Maximum Load 360 lbs (163 kg) Brace Identification on Plans 2.5" Long Prying Factor N/A Brace Type Lateral [ ] Longitudinal [X] 4-Way [ ] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 2.5" (65 mm) Sch. 10 180 ft (24.4 m) 80 ft (24.4 m) 5.89 Nit (8.77 kg/m) 471 lbs (214 kg) Subtotal Weight 471 lbs (214 kg) Wp (incl. 15%) 542 lbs (246 kg) Main Size Type/Sch. 2.5" Sch. 10 Spacing (ft) 80 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 327lbs (148 kg) N/A tTOLbrace'" Version Bl Use of TOLBrace'" is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Bracing Calculations V8.8.137 Contractor: Project Address: Kruger Medical Building Address: E:t•N 21600 Hwy 99 Phone: PowenngBusiness WoddW6 Edmonds, WA License: Job # Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTm Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 7' 0" (2.134 m) Diameter of Brace 1 Fig. 4L Clamp 1600 lbs (726 kg) 1659 lbs (752 kg) Fig.980 -1/2" Universal Swivel 2100 lbs (953 kg) 2178 lbs (988 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOn" components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 TOLCO FIG. 980 Max Horizontal Load 1310 lbs (594 kg) 0 BRACE PIPE Fastener Information Orientation to Connecting Surface NFPA Type B Fastener 112 x 3-1/2 (13 x 89 mm) Dual Lag Bolts Perpendicular to Beam - TOLCO Type Fig 906 Diameter 1/2in. (13 mm) Length 3-1/2in. (89 mm) Maximum Load 360 lbs (163 kg) TOLCO FIG. 41. Brace Identification on Plans 6" RISER -ATTIC Prying Factor N/A Brace Type Lateral [ ] Longitudinal [ ] 4-Way [X] Sprinkler System Load Calculation (Fpw = CpWp) = 0.6028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6" (150 mm) Sch. 10 15 ft (4.6 m) 15 ft (4.6 m) 23.03 Ib/ft (34.27 kg/m) 345 Ibs (156 kg) Subtotal Weight 345lbs (156 kg) Wp (incl. 15%) 397 Ibs (180 kg) Main Size Type/Sch. 61. Sch. 10 Spacing (ft) 16 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 239lbs (108 kg) N/A tTULBrace'"' Version 61 Use of TOLBrace "" is subject to terms and conditions per the end user license agreement i 216th St SW Ot9 �1 Ry 21600 Highway 99, Edmonds, WA 98026 -Z Swedish Cancer Institute Medical Oncology ►A C 1216th St C 9Jeff's Auto Repair try ifc If Your 8uilifing McKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S SEATTLE, WA 98134 1-206-762-3311 www.mckinstry.com PROJECT: Kruger Medical Building 21600 Hwy 99, Edmonds WA 98026 CONSULTANTS: REGISTRATION: l- - - - - - - - - - - - - - - - - - - - - - - - - - Expires WASHINGTON STATE ; CERTIFICATION OF COMPETENCY 12/31/24 FIRE SPRINKLER SYSTEMS Patrick Acierto 1 7329-1022-C Level 1 McKinstry, LLC MCKINCL942DW 1 1 08/16/2024 1 Sign ur Date 1 ISSUES: DESIGNED BY: BN DRAWN BY: BN CHECKED BY: PA JOB NO: 124675 ISSUED ON: SHEET TITLE: COVER PAGE ATTIC FIR2024-0096 RECEIVED / Oct 01 2024 / CITY OF EDMONDS SHEET NUMBER: DEVELOPMENT SERVICES DEPARTMENT F1 03 7:12 ROOF SLOPE PER ORIGINAL BUILDING ARCHITECT SET. n Level 3 1 /8" = 1'-0" - .!►I.r�N :till ` � �� � � I� _ l,IfiN PIPE SPACING REFERENCED AND APP IN ARCHIVED BUILDING BLUEPRINTS. SPRINKLER SCHEDULE ATTIC QTY DESCRIPTION COLOR MFG MODEL SIN K-FCTR THIRD TEMP O 3 Reliable 1/2 Ordinary Upright Quick Response BRONZE Reliable F1FR56 RA1425 5.6 1/2" 200 OF 133 Reliable Light Attic -Single Direction Quick Response BRONZE Reliable DS56 RA5625 5.6 1/2" 212 OF 12 Reliable Light Upright Quick Response BRONZE Reliable GP56 RA5695 5.6 1/2" 212 OF 4:148 Total No. of Sprinklers:148 CO ACTUAL PIPE R GC REQUEST S INSPECTORS TEST TO BE INSTALLED NEAR COLUMN. COORDINATE WITH GC EXACT LOCATION. myarauncany ualculatea System This system as shown on RA3l ATTIC company print no. F103 dated 7/3/2024 fort Kruger Medical Building at 21600 Hwy 99 contract no. 124675 is designed to discharge at a rate of .127 gpm (L/min) per sq ft (m2) of floor area over a maximum area of 406 sq ft (m2) when supplied with water at the rate of 313 gpm (L/min) at 56.37 psi (bars) at the base of the riser Hose stream allowence of 250 GPM gpm (L/min) Occupancy classification Maximum storage height N/A Installed by McKinstry UP FROM 2ND FLOOR. 6 GP56 HEADS PLACED TO COVER UNPROTECTED AREAS CREATED BY DS56 DISCHARGE PATTERN. tr (: ifc If Your 0uilwliny WKINSTRY Co, LLC SEATTLE: 5005 3RD AVENUE S SEATTLE, WA 98134 1-206-762-3311 www.mckinstry.com PROJECT: Kruger Medical Building 21600 Hwy 99, Edmonds WA 98026 CONSULTANTS: COMMENT: THIS REGISTRATION: SHOULD READ r-------------------------- LIGHT HAZARD. Expires WASHINGTON STATE 1 1 CERTIFICATION OF COMPETENCY PLEASE ENSURE ; 12/31/24 FIRE SPRINKLER SYSTEMS THE FINAL PLATE Patrick Acierto INDICATES LIGHT 1 7329-1022-C Level 3 1 McKinstry, LLC DFM BURT MCKINCL942DW 1 1 08/16/2024 1 Sign ur Date 1 ISSUES: DESIGNED BY: BN DRAWN BY: BN CHECKED BY: PA JOB NO: 124675 ISSUED ON: SHEET TITLE: LEVEL 3 FIRE SPRINKLER PLAN FIR2024-0096 SHEET NUMBER: F 104 RECEIVED Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT