Loading...
FIR2024-0096+Calculations+10.1.2024_10.34.43_AM+4533667FI R2024-0096 of EDA 04/' s WATER AVAILABILITY APPLICATION Complete and submit this form through www.MyBuildingPermit.com. Submit as a new application using the following prompts: Application Type — Utilities, Activity Type — Utility Availability, Scope of Work — Water Main. Vc. `Sa'' RECEIVED Oct 01 2024 SECTION A CITY OF EDMONDS IF SERVICES MENT Applicant Contact/Applicant Name Robert Fix Phone Number 206-762-3311 Email permits@mckinstry.com .com Address 5005 3rd Ave S city Seattle State WA zip 98134 Property Information Kruger Building Renovation Address21600 H i hwa 99 cil'Edmonds State WA zip 98026 Parcel No. 00580700002900 Does the property currently have water service? Ayes (City of Edmonds water) ❑ No Describe project (number of buildings, number of units, number of stories per building): Two story fire sprinkler TI. In what phase is the project? ❑ Design Review ❑ Preliminary Plat Auilding Permit ❑ Rezone or Other Associated permit application number(s), if applicable: SECTION B Applicability Exemptions from Utility Availability Study: 1) Single-family residence; 2) Multi -family project of four units or less with combo water/fire lines; 3) Short plat subdivision (four single-family lots or less). Please check one of the following: ❑ A utility availability study IS NOT requested/required. The applicant certifies that this project is exempt from needing a study as described above and is not requesting a full utility availability study at this time. Please sign below and submit this form through www.MyBuildingPermit.com. )E�A utility availability study IS requested/required for the project, and associated fees will be due. Please submit the complete application through www.MyBuildingPermit.com. APPLICANT SIGNATURE: &Oza DATE: 3/14/2024 APPLICANT PRINTED NAME: Baley Norton Form Updated 3/28/2023 FI R2024-0096 SECTION C 1. E a. Water will be provided by service only to an existing 6" DI (size) water main that is (feet) from the site. OR Elb. Water service will require an improvement to the water system of: RECEIVED ❑ W. feet of water main to reach the site; and/or Oct 01 2024 ❑ (2). The construction of a distribution system on the site; and/or CITY OF EDMONDS El (3). Other (describe) DEVELOPMENT SERVICES DEPARTMENT 2. 0 a. The water system is in conformance with a City approved water comprehensive plan. OR ❑ b. The water system improvement will require a water comprehensive plan amendment. (This will cause a delay in permit issuance and approval.) 3. ❑s a. The proposed project is within the corporate limits of the City, or has been granted Boundary Review board approval for extension of service outside the City, or is within the City approved service area of a private water purveyor. OR ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 4. ❑s a. Water is/or will be available at the rate of flow and duration indicated below at no less than 20 psi - Measured at the nearest fire hydrant 43 feet from the building/property (or as marked on attached map) Rate of Flow Duration ❑ Less than 500 gpm. (approximately gpm) ❑ Less than one (1) hour ❑ 500 to 999 9Pm ❑ 1500 gpm or more ❑ One (1) to two (2) hours ❑ Two (2) hours or more ❑ Flow test of gpm ❑ Other 0 Calculation of 1421.37 gpm (Commercial building permits require flow test or calculation) OR ❑ b. Water system is not capable of providing fire flow. Water Agency Certification Comments/Conditions: Static Pressure: 102.69 psi Residual Pressure at Available Flow: 97.73 psi Maximum Flow: 1421.37 gpm I hereby certify that the above information is true. This certification shall be valid for one year from the date of signature. City of Edmonds Jenelle Ho (Agency Name) (Signatory Printed Name) Engineer Digitally signed by Jenelle Ho oDN:f Egenelle ho@edmondma.g O=TheAssociate City of Elmonds,OUnIeIeHoJeneIIe H E (Title) (Signature/Date) Form Updated 3/28/2023 FI R2024-0096 ristry Of Your Building Expires WASHINGTON STATE ; CERTIFICATION OF COMPETENCY 1 12/31/24 FIRE SPRINKLER SYSTEMS 1 1 1 Patrick Acierto 1 7329-1022-C Level 1 McKinstry, LLC MCKINCL942DW 1 1 10/01 /2024 1 Signature Date 1 McKinstry 5005 3rd Ave S Seattle, WA 98134 1-206-762-3311 Job Name Kruger Medical Building Drawing F104 Location 21600 Hwy 99 Remote Area 3 Contract 124675 Data File Kruger Medical Building Area 3.WXF RECEIVED Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Computer Programs by Hydratec Inc. Revision: 50.5520.727 Water Supply Curve McKinstry Kruger Medical Building FI R2024-0096 Page Date City Water Supply: Demand: C1 - Static Pressure : 102.69 D1 - Elevation 8.619 C2 - Residual Pressure: 97.73 D2 - System Flow : 212.733 C2 - Residual Flow 1421 D2 - System Pressure 56.373 RECEIVER ( Demand ) : 100 System Demand : 312.733 Oct 01 2024Safety Margin 46.016 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 150 140 130 P 120 R 110 C1 C2 E 100 S 90 S 80 U 70 R 60 E 50 3 40 30 20 10 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA1.85) Computer Programs by Hydratec Inc. Revision: 50.5520.727 Fittings Used Summary McKinstry Kruger Medical Building Fitting Legend Abbrev. Name E NFPA 13 90' Standard Elbow T NFPA 13 90' Flow thru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units FI R2024-0096 Page 2 Date '/2 3/4 1 14 1'/2 2 2'h 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 3 4 5 6 8 10 12 15 17 20 20 Efj; EfN �u 60 71 81 91 101 121 Oct 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.5520.727 Flow Summary - NFPA McKinstry FIR2024-0096 Page 3 Kruger Medical Building Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 315 102.69 97.73 1421.0 102.389 312.73 RECEIVED Oct 01 2024 CITY OF EDMONDS NODE ANALYSIS DEVELOPMENTDEPARTMENRVICES Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 300 22.9 5.6 16.9 23.02 0.127 180 301 22.89 5.6 16.92 23.03 0.127 180 302 22.89 5.6 16.95 23.06 0.127 180 303 22.9 5.6 17.03 23.11 0.127 180 304 22.87 5.6 17.18 23.21 0.127 180 305 22.87 5.6 17.75 23.59 0.113 150 306 22.86 5.6 18.64 24.18 0.127 180 307 22.84 5.6 19.2 24.54 0.127 180 308 22.83 5.6 19.92 24.99 0.127 180 309 22.6 40.6 310 22.01 47.32 311 20.72 48.2 500 4.52 55.4 312 1.0 57.07 313 -6.83 60.5 314 -6.83 60.5 315 3.0 56.37 100.0 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations : Hazen -Williams McKinstry FIR2024-0096 Page 4 Kruger Medical Building Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 300 22.9 5.60 23.02 2.5 to 301 22.89 23.02 2.635 301 22.89 5.60 23.03 2.5 to 302 22.89 46.05 2.635 RECEIVED 4.000 100 16.900 0.004 Oct 01 2024 4.000 0.0028 0.011 Vel = 1.35�ITy OF EDMONDS DEVELIT SERVICES 4.000 100 16.915 DEPARTMENT 0.0 4.000 0.0098 0.039 Vel = 2.71 302 22.89 5.60 23.06 2.5 4.000 100 16.954 to -0.004 303 22.9 69.11 2.635 4.000 0.0202 0.081 Vel = 4.07 303 22.9 5.60 23.11 2.5 to 304 22.87 92.22 2.635 304 22.87 5.60 23.21 2.5 E to 305 22.87 115.43 2.635 305 22.87 5.60 23.59 2.5 E to 306 22.86 139.02 2.635 306 22.86 5.60 24.18 2.5 to 307 22.84 163.2 2.635 307 22.84 5.60 24.54 2.5 to 308 22.83 187.74 2.635 4.000 100 17.031 0.013 4.000 0.0348 0.139 Vel = 5.43 5.879 4.820 100 17.183 5.879 0.0 10.699 0.0526 0.563 Vel = 6.79 5.879 6.140 5.879 12.019 5.500 I Il 5.500 5.500 100 17.746 0.004 0.0742 0.892 Vel = 8.18 100 18.642 0.009 0.0998 0.549 Vel = 9.60 100 19.200 0.004 0.1296 0.713 Vel = 11.05 308 22.83 5.60 24.99 2.5 4E 23.515 102.670 100 19.917 to 23.516 0.100 309 22.6 212.73 2.635 126.186 0.1631 20.579 Vel = 12.52 309 22.6 0.0 4 12E 112.768 299.050 100 40.596 to 112.768 0.256 310 22.01 212.73 4.26 411.818 0.0157 6.473 Vel = 4.79 310 22.01 0.0 4 T 18.795 1.300 100 47.325 to 18.795 0.559 311 20.72 212.73 4.26 20.095 0.0157 0.315 Vel = 4.79 311 20.72 0.0 6 4E 50.252 32.130 100 48.199 to 50.252 7.016 500 4.52 212.73 6.357 82.382 0.0022 0.185 Vel = 2.15 500 4.52 0.0 6 E 17.603 5.950 120 55.400 to T 37.72 82.984 1.525 312 1 212.73 6.357 Eql 27.661 88.934 0.0016 0.141 Vel = 2.15 312 1 0.0 6 E 20.084 7.830 140 57.066 to 20.084 3.391 313 -6.83 212.73 6.16 27.914 0.0014 0.040 Vel = 2.29 313 -6.83 0.0 6 2.590 140 60.497 to 0.0 314 -6.83 212.73 6.16 2.590 0.0012 0.003 Vel = 2.29 314 -6.83 0.0 6 2E 40.168 52.830 140 60.500 to 40.168 -4.257 315 3 212.73 6.16 92.998 0.0014 0.130 Vel = 2.29 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations: Hazen -Williams McKinstry FIR2024-0096 Page 5 Kruger Medical Building Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf RECEIVED 100.00 Qa _ �t1 2024 315 312.73 56.373 K Factor CITY OF EDM ND DEVELOPMENT SERVICES DEPARTMENT Computer Programs by Hydratec Inc. Revision: 50.5520.727