Loading...
RESPONSE 1 FIRE-FIR2024-0034+4.30.2024_11.39.21_AM+4227319RESUB Apr 30 2024 HOOD SUPPRESSION SYSTEM CORRECTION LETTER RESPONSE City of Edmonds RE: Ivars, 9910 Edmonds Way FIR2024-0034 30 Apr 2024 Attn: Fire Marshal office/DFM Burt In response to plan review corrections dated 24 Apr 2024 1. Provide Proper ICC Certification PSI Response - ICC Certification 10087093 for Matthew Neilson attached. 2. Provide authorization certificate to work on suppression manufacturer equipment PSI Response - system manufacturer is Range Guard (Badger). Badger Range Guard certification of Thea Ray attached 3. Describe the reason for 500°F Degree Links PSI Response - Attached photo should help - this is a 'low proximity" hood. The temperature of the exhaust from deep fryers has caused system activation in a similar system within South County Fire's response area (131 A ve Pub in Martha Lake) installed with links rated for lower temperatures. (Note: the wood topped table adjacent to the equipment, circled, will be replaced with stainless steel) - System responsible party.- Max (Matthew) Neilson is available for discussion on thismatter 206.503.5251 or max. neilsonPpsintegrated.com 4. Response letter Required 5. Confirm that all components of the suppression system are either Range Guard or Badger We confirm that all components listed as part of the "Badger Range Guard Wet Chemical System " Prepared By: PERFORMANCE SYSTEMS INTEGRATION Pacific Northwest Puget Sound Portland Inland 301 Porter Way 7324 SW Durham Rd 4004 E Trent Ave Milton, WA 98354 Portland, OR 97224 Spokane, WA 99202 Licenses: 675521 (CA), CLE569 (OR), PERFOSI81250 (WA), PERFOSIS1850 (WA) Job Ivars, Edmonds: Rev1 - April 30, 2024 INTERNATIONAL CODE COUNCIL° INTERNATIONAL CODE COUNCIL MATTHEW NIELSON The International Code Council attests that the individual named on this certificate has satisfactorily demonstrated knowledge as required by the International Code Council by successfully completing the prescribed written examination based on codes and standards then in effect, and is hereby issued this certification as: Pre-engineered Kitchen Fire Extinguishing Systems Technician Greg , eler, CBOT Given this day September 17, 2021 Certificate No. 1 ON 93 OF FIRE FQ O This certificate is the property of ICC and must be returned to ICC in the event of suspension or revocation of the certificate. 4/29/24, 7:44 PM Training Certificate eatficAe of �01#jo/e#0)7 This is to certify that Thea Ray an employee of PERFORMANCE SYSTEMS INTEGRATION, LLC on behalf of KIDDE SAFETY an Authorized Badger Fire Protection Distributor has successfully completed a certification training session covering design, installation, operation and maintenance and has demonstrated a practical knowledge of following Michael Kraus Training Manager Badger products: Range Guard Wet Chemical BADGER 19M Issue Date: 4/30/2024 Expiration Date: 4/30/2027 This certificate is not transferrable. Certificate is only valid as long as the above named company employs the training participant. Acceptance of this certificate implies that the parties agree to abide by the terms of the distributor agreement or absent an agreement Kidde Fire Systems Terms and Conditions of Sale. Any violation or alteration of this certificate will result in the immediate voiding of this certificate and possible revocation of access to the Kidde Fire Systems product line hftps://www.kidde-fenwal.com/Training/Certificate?id=51712 1 /1