REVIEWED FIR2024-0040+Fire_Sprinkler_Equipment_Specification_Sheets+5.27.2024_8.49.46_AM+4283355
RECEIVED F I R2024-0040 May 30 2024 • Ships as complete kit, including: — System & test cartridges — One System Valve Actuator (SVA) — Two pigtail type micro -switches — Three EMT connectors — English, French & Spanish labels • Integrated local manual release • Die cast aluminum base & high impact polycarbonate cover — Durable, corrosion resistant • All ports are knockout — Contaminant resistant • Actuate up to 20 cylinders • Two independent detection lines — Up to 200 feet of cable on each line • Mechanical and/or electrical actuation • Connect up to 4 microswitches — Two knockout ports for signal/AC line separation • Control 2 gas valves on single line • Control 2 remote releases on single line • Wall or cylinder mount • Multiple remote release options a L 92 CYLINDER & VALVE ASSEMBLIES Capacity I Kidde Flow Model 6 PM Points 1 33 Gallon WHDR-125 (5.0liter) 87-120001-001 4 2 66 Gallon WHDR•260 (10 1 liter) 87-120002-001 .. 8 4 Gallon Short WHDR�OOS (15 1 liter) 87-120003-001 .1 off o t2 4 Gallon Medium WHDR-4OOM (15 1 Ider) 87-120006-001 .1 too. o 12 6 Gallon WHDR-600 (22-7 liter) 87-120 005-001 .1 ..f of 18 73 CYLINDER & VALVE ASSEMBLY • Stored Pressure design _r 175 PSIG (12.1 bar) at 70°F (21°C)� • DOT & (TC) stamped 4BW (4BWM) or 4BA (4BAM) • Cylinder pressure rating 250 psi (17.2 bar) or 225 psi (15.5 bar) • Pneumatically actuated valve assembly • Multi-lingual nameplates (English, French, Spanish) _4 Badger Range Guard® Nozzle Parameters' L� Duct (see page 2 for coverage table) Perimeter Max Diameter Max Length Nozzle Type Flows Manual # Up to 50' Perimeter Duct (11 78' max throw) 50` 15 91" Unlimited ADP 1 _Pane 3-35 Up to 100" Perimeter Duct (11 78" max throw) 100" 31 83" Unlimited ADP (min 2) 1 ea 3-36 Greater than 100" Perimeter Duct (11 78" max throw) Refer to manual Refer to manual Unlimited ADP 1 ea 3-37 Plenum Length Max Width Max Filters Nozzle Type Flows Manual Page # Plenum 10' 4' ' V" Bank or Singe ADP 1 3-33 Appliance Cooking Area inches Nozzle Height/Dist inches Nozzle Position Nozzle Type Flows Manual Page # Range, Four -Burner 28 X 28 20 to 42 W'thin 9' radius of mid point R 1 3-15 Range, Low Proximity 24 x 24 16 to 20 Centered over hazard LPR 1 3-18 Griddle (with or without raised ribs) 30 X 42 13 to 48 On per meter, aim w/in 3" rad of I ADP 1 3-27 Fryer. Single Vat (Drip Board up to 5') 18 X 18 27 to 45 45' to 90' from horizontal F 2 3-6 Fryer, Single Vat (2 nozzle, Drip Board up to 6-1/2") 18-1/2 X 18 27-1/2 to 45 45` to 901 from horizontal (2) F 2 ea 3-7 Fryer, Single Vat (Drip Board up to 10-1/2") 14 x 14 27-1/2 to 45 45' to 90' from horizontal F 2 3-9 Fryer. Single Vat (Drip Board less than 1") 24 x 24 27-1/2 to 46 On or within perimeter F 2 3-10 Fryer, Single Vat - Low Prox (Drip Board up to 7-3/4") 14 X 15-1/2 12 to 24 3.5" to 13.5" offset' Min 8 flow pts on system LPF 2 3-12 Fryer. Split Vat (Drip Board up to 6") 14 x 15 27 to 45 45" to 90' from horizontal F 2 3-8 Fryer Split Vat - Low Proximity (Drip Board to 6') 14 x 15 16 to 27 On or within perimeter ADP 1 3-11 Krispy Kreme Model 270 d/h Doughnut Fryer 93 x 33 22-1/2 to 29-1/2 See Table 3-11 & Fig 3-9 (8) ADP 1 ea 3-14 Wok I to 8" deep) 14 to 28 dia 35 to 56 2' offset from center GRW 1 3-28 Tilt Skillet / Braising Pan 24 x 24 27-1/2 to 46 Front edge within perimeter F 2 3-29 Upright Broiler Salamander Broiler 30-1/4 X 34 Top 4" of broiler comp See Table 3-19 ADP 1 3-20 Chain Broiler, Closed Top (%' pipe on nozzle drop) 28 X 29 See Table 3-24 See Table 3-24 & Fig 3-20 ADP 1 3-25 Chain Broiler. Open Top (1W pipe on nozzle drops) 28 X 29 See Table 3-25 See Table 3-25 & Fig 3-21 (2) ADP 1 ea 3-26 Charbroiler. Gas - Pumice Lava, Ceramic Synth Rock 25-1/4 X 24 30 to 48 On or within perimeter. max 2 rock ayers F 2 Addendum Charbroiler. Gas - Radiant / Electric — option 1 21 X 24 24 to 48 45' to 90' from horizontal GRW 1 3-22 Charbroiler. Gas - Radiant / Electric — option 2 25-1/4 x 36 34 to 45 On or within perimeter F 2 Addendum Charcoal Broiler, Natural or Mesquite Charcoal 24 X 24 24 to 48 45' - 90' max 6" fuel depth ADP 1 3-23 Mesquite Log Charbroiler (wood chips, chunks or logs) 30 X 24 24 to 48 45" - 90' max 10" fuel depth DM 3 3-24 "Summary sheet for reference only Refer to Badger Range Guard Design Instal at, on Operation & Maintenance Manua P/N 60-9127100-000 for complete design and Installation requirements pyright r)2016 Ktdde-Fenwal Inc Range Guard s a reg sti trademark of Badger F re Protection Badger Fire Protection 944 Glenwood Station Charlottesville VA 22901 Badger Range Guard® System Parameters" Controls & Detection Detection Line UCH Control System A+ Control Head 87-120099-002 87-120010-000 Max Number of Corner Pulleys 50 (each line) 40 Max Cable Length 200 ft (each line) 200 ft Manual Pull Max Number of Corner Pulleys 50 Release -to -Trip (each line) 40 30 Pull -to -trip line Max Length of Cable 200 ft Release -to -Trip (each line) 100 ft Pull -to -Trip line Inline w/detection cable MPrhaniral Gas 1 ine Max Number of CornerPulleys 30 16 Max Length of Cable 100 ft 50 ft Actuation Tubina (114" cooper tubino. comoresslon or flare fittinas 1-12 Cylinders: 106 ft max. 5' min 23 ft total. 5� Length 13-20 Cylinders: 91 ft max. S min Min 3'' to 1 cylinder 20from 1 s' to last cylinder Fusihle A Thennnhulh Link Detertnrs Type ML. A-360. BTBS, BTBR. DAF A-360, BTBS, BTBR Max Quantity 40 (each line) 40 Detector Brackets Model 60-120064-001,WK-804548-000 60-120064-001 Microswitches Max Quantity 4 (pigtail or terminal type) 2 Cylinders Cylinder Flow Points Diam (in) Height (in) (top of SVA RG-1.25G 4 8 17 RG-2 5G 8 9 22-3/4 RG-4GS 12 1 12-1/4 20-3/4 RG-4GM 12 10 26-3/16 RG-613 18 10 36-15/16 Rectangular Duct Coverage Single ADP Duct Coverage Two ADP Duct Coverage Side A (in) Max Side B (in) 210 40 205 4.5 20.0 50 195 55 19.0 6.0 185 65 18.0 7.0 175 75 170 80 165 85 160 9.0 155 9.5 150 100 14.5 10.5 14.0 11 0 135 11 5 13.0 120 125 125 Piping Flow Demand Min Pipe Size 1-2 1/4" 1-8 3/8" 1-12 1/2" 13 - 24 3/4" 25 - 48 1 " Side A I Max Side B in (mm) in (mm) 440 60 430 7.0 42.0 8.0 41.0 9.0 400 100 39.0 110 38.0 120 370 130 36.0 140 350 150 340 16.0 330 16.8 320 17.2 31 0 177 300 181 29.0 185 280 189 270 193 260 197 250 19.9 24.0 20.2 23.0 205 22.0 208 21.0 21.0 'Summary sheet for reference only Refer to Badger Range Guard Design, Installation Operation & Maintenance Manual P/N 60-9127100-000 for complete design and installation requirements >pyright ©2016 Kidde-Fenwal Inc Range Guard !s a registered trademark of Badger Fire Protection Badger Fire Protection 944 Glenwood Station Charlottesville VA 22901 System Design DUCT NOZZLE DUCT 4 ft. (1.2 m) 4 ft. (1.2 m) 10 ft. (3 m) "V" FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 4 ft. (1.2 m) 4 ft. (1.2 m) NOZZLE NOZZLE DUCT 4 ft. (1.2 m) 20 ft. /`. (6 m) 4 ft. (1.2 m)� "V" FILTER BANK COVERAGE 20 ft. (6 m) PLENUM a�O NOZZLE 3/4 H ti i H "V" FILTER BANK COVERAGE (END VIEW) NOZZLE SINGLE FILTER BANK COVERAGE 10 ft. (3 m) PLENUM NOZZLE ♦11/3 WI♦ I 3/4 Ha _ _ T H I♦ W -►I SINGLE BANK FILTER COVERAGE (END VIEW) Figure 3-28. ADP Protection Nozzle, P/N B 120011 April 2009 P/N 60-9127100-000 NOZZLE DUCT �. 20 ft. (6 m) 4 ft. (1.2 m)1*-/ SINGLE FILTER BANK COVERAGE 20 ft. (6 m) PLENUM System Design 3-6.1.1 DUCTS The ADP nozzle, P/N 87-12001 1-001, is used for protection of the exhaust ductwork. The duct cross section can be any shape, not including obstructions (i.e., round, square, or rectangular) and the duct itself can be of unlimited length. In accordance with NFPA 96, the exhaust fan should be left running at the time of system discharge. This will help to remove smoke and other airborne materials and gases from the hazard area in the event of a fire. Check with the Authority Having Jurisdiction for local requirements. A damper, if present, should be left open at system discharge. However, if the damper is closed, the system designer must insure that additional nozzles are required. 3-6.1.1.1 Protection of Ducts 0 to 50 inches in Perimeter One ADP nozzle, P/N 87-12001 1-001, is required for protection of a duct with a perimeter up to 50- inches (refer to Figure 3-29). Length of duct is unlimited. The nozzle is located at the geometric center of the cross -sectional area that it is protecting, and is located in the duct within six inches of the entrance. Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT PERIMETER UP TO AND INCLUDING 50 in. (1270 mm) 11.78 in. (300 mm) 15.91 in. MAX. DIAGONAL (404 mm) ♦ ♦ MAX. I� „B,. 12.5 in. 11.78 in. (300 mm) (318 mm) — I ? MAX. DIAGONAL MAX. I — o— A„ ♦ I tr SQUARE DUCT RECTANGULAR DUCT 2 "A" + 2 "B" = 65 in. (1651 mm) ROUND DUCT Q. i ADP NOZZLE i 0-6in.(0-152mm) DUCT ENTRANCE t (L OF VERTICAL DUCT i VERTICAL/HORIZONTAL DUCT AIM POINT i ADP NOZZLE (. OF HORIZONTAL DUCT 2 to 4 in. (51 to 102 mm) NOZZLE TIP to DUCT HIP Figure 3-29. Duct Protection Using Single ADP Nozzle, P/N 87-120011-001 P/N 60-9127100-000 3-35 April 2009 System Design 3-4.21 Wok Table 3-27. GRW Nozzle Coverage Area Items Parameters Wok Diameter 14 in. to 28 in. (356 mm to 1829 mm) Wok Depth 3 in. to 8 in. (76 mm to 508 mm) Nozzle Aim Center of Wok Nozzle Location — Must be over center and within 2 in.'(51 mm) 35 in. (889 mm) Min. from center and nozzle height must be measured over center- and within 2 in. (51 mm) from center from inside bottom of Wok. 56 in. (1422 mm) Max. Only one nozzle per Wok. 56 in. (1422 mm) MAX. 35 in. (889 mm) 1 MIN. 1 3 in. (76 mm) TO 8 in. (203 mm) DEPTH Figure 3-23. Wok 2 in. (51 mm) MAX. OFFSET ONE GRW NOZZLE MUST BE LOCATED ANYWHERE WITHIN THE SHADED AREA AIMED AT CENTER OF WOK 14 in. (356 mm) TO 28 in. (711mm) DIAMETER CENTER OF HAZARD AREA AT BASE WOK INSIDE BOTTOM System Design 3-4.15 Gas Radiant/Electric Charbroiler Table 3-21. GRW Nozzle Coverage Area Items parameters 1 21 in. x 24 in. 15a3 mill LV " Maximum Cooking Surface Midpoint of the hazard area above cooping s ace -------------- Nozzle Aim -- Nozzle Location (located at an angle of 45' or more from 24 in. (616 mm) Min. - - 48 in. (1219 mm) Max. the horizontal I 48 in. (1219 RIM) MAX. 24 In. (610 MM) MAX. 21 In.(533 �/ MAX. YBE LOCATED ANYWHERE WITHIN THE GRID DIAGONAL FROM AIM POINT 48 in. 0219 mm) MAX. AIM POINT: MIDPOINT OF HAZARD AREA A GRW NOZZLE MAY 8 LOCATED ANYWHERE WITHIN THE GRID I I NOZZLE LOCATION z f � FF � 45' OR MORE FROM HORIZONTAL c E • a �ti•• a E o C' AIM POINT: ` � m p� MIDPOINT OF ` HAZARD AREA ` RADIANT LAYER GAS FLAME ptP ( MAX. FAPPLIANCE AREA 24 In. (610 mm) SIDE VIEW MAX - FRONT VIEW Figure 3-17. Gas Radiant/Electric Charbroiler PIN 60-912 System Design 4 Four Burner Ranges Table 3-13. R Nozzle Coverage Area — Four Burner Range Items Parameters I Maximum Hazard Area 28 in. x zts in. t i i i rnm x i i i mml ?nozzle Aim Midpoint of Hazard Area i Nozzle Location — Anywhere within the area of a circle 20 in. (508 mm) Min. generated by a 9 in. (229 mm) radius about the midpoint 42 in. (1067 mm) Max. note: Shape of burner not important. I 18 in. (457 mm) DIA ' 42 in. (1067 MAX. I OF (FROM TOP OF RANGE) A'R' NOZZLE MAY BE LOCATED ANYWHERE WITHIN I THE SHADED AREA 20 in. (508 mm) MIN. _ 1 AIM POINT: MIDPOINT OF (FROM TOP OF HAZARD AREA F� RANGE) LT , f � r 28 in. (711 mml 14 In. (356 mm) MAX. MAX HAZARD BURNER CENTERLINE AREA LENGTH TO CENTERLINE n. (356 mm) MAX.NER CENTERLINE r O CENTERLINE 11 mm) MAX. AREA WIDTH Figure 3-10. R Nozzle Coverage for a 4-Burner Range P/N 60-9127100-000 April 2009 2 18-1/2 in. x 24-1/2 in. Deep Fat Fryer With Drip Board Table 3-3. F Nozzle Coverage Area Parameters Items um Hazard Area 18-1/2 in. x 18 in. (470 mm x 457 mm) �: um Appliance Area (with drip board) 18-1/2 in. x 24-1/2 in. (470 mm x 622 mm) Midpoint of module area per nozzle dazzle Aim------------- lhozzle Location (at an angle of 45" or more from the horizontal 27 in. (6m9 mm) Min. move each module) 45 in.n. (1 143 mm) Max. lfodule Area (half of hazard area) 18-1/2 in. x 9 in. (470 mm x 229 mm) AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45 In 1143 mml MAX 27.112 In- (699 mm) MIN. y FRONT OF 18.112 in. O qj APPLIANCE (470 mm) 0 MAX Imo_ 9 in. — ► • 9 in — (229 mm1 (229 mm) - 24-1/2 in - (622 mm) MAX SIDE VIEW 2 F NOZZLES ARE REQUIRED FOR THIS APPLIANCE AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID NOZZLE LOCATIC 45° OR MORE FRG... HORIZONTAL (TYP) AIM POINT: MIDPOINT OF HAZARD AREA HAZARD AREA 45 in. AN F NOZZLE MAY BE LOCATED 4S in. ANYWHERE WITHIN THE GRID (1143 mm) (1143 mm) MAX MAX DIAGONAL FROM AIM POINT 45 in (1143 mm) MAX IMAGINARY LINE /DIVIDING MODULES MIDPOINT OF r MODULEAREA AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID DRIP BOARD 18-112 in. (470 mm) MAX. N 24-112 in. (622 mm) MAX. APPLIANCE AREA SIDE VIEW Figure 3-3. 18-1/2 in. x 24-1/2 in. (470 mm x 622 mm) Deep Fat. Fryer April 2009 - _° 27100-000 3 7