APPROVED PLN RESUB1 BLD2024-0627+SITE & Architectural_Plan+6.8.2024_3.19.20_PM+4309846ABBREVIATIONS
@
AT
FBOIC
FURNISHED BY OWNER
PASS.
PASSENGER
q
CENTERLINE
INSTALLED BY CONTRACTOR
P.B.
PANIC BAR
R
PROPERTY LINE
FBOIO
FURNISHED BY OWNER
P.BD.
PARTICLE BOARD
D
PENNY
INSTALLED BY OWNER
P.C.
PRECAST CONCRETE
l
PERPENDICULAR
FCB
FIBER CEMENT BOARD
PERF.
PERFORATE(D)
#
POUND OR NUMBER
F.D.
FLOOR DRAIN
PERT.
PERIMETER
0
DIAMETER
FDN
FOUNDATION
PL
PLATE
SQUARE FEET
F.E.
FIRE EXTINGUISHER
P.L.
PROPERTY LINE
F.E.C.
FIRE EXTINGUISHER CABINET
RLAM
PLASTIC LAMINATE
A.B.
ANCHOR BOLT
F.F.
FACTORY FINISH
PLAS.
PLASTER
A/C
AIR CONDITIONING
FIN
FINISH(ED)
PLYWD
PLYWOOD
ACC.
ACCESSIBLE
FLR('G)
FLOOR(ING)
PNL
PANEL
ACOUS.
ACOUSTICAL
FLSH'G
FLASHING
P.O.
PURCHASE ORDER
ACT
ACOUSTIC TILE
FLUOR.
FLUORESCENT
PR.
PAIR
A.D.
AREA DRAIN
F.O.S.
FACE OF STUDS
P.S.F.
POUNDS PER SQ. FOOT
ADD.
ADDENDUM
F.O.C.
FACE OF CONCRETE
P.S.I.
POUNDS PER SQ. INCH
ADJ
ADJACENT
F.O.F.
FACE OF FINISH
PT
POINT
ADJUS
ADJUSTABLE
F.O.B.
FACE OF BRICK
P.T.
PRESSURE TREATED
AFF
ABOVE FINISH FLOOR
F.O.M.
FACE OF MASONRY
PD.
PLANTER DRAIN
AGGR.
AGGREGATE
FP.
FIREPROOF
PTN.
PARTITION
ALT
ALTERNATE
FT
FOOT, FEET
PVMT
PAVEMENT
AL., ALUM
ALUMINUM
FTG
FOOTING
P.T.D.
PAPER TOWEL DISPENSER
ANOD
ANODIZED
F.T.V.
FIXED SECURITY TELEVISION
APPROX.
APPROXIMATE
FURR
FURRED, FURRING
Q.T.
QUARRY TILE
ARCH
ARCHITECT
FUT.
FUTURE
ARCH'L
ARCHITECTURAL
F.R.G.
FIBERGLASS REINF. GYPSUM
(R)
REUSED, RELOCATED
ASPH
ASPHALT
FV
FIELD VERIFY
R.
RISER
AN
AUDIONISUAL
F.W.C.
FABRIC WALLCOVERING
R.A.
RETURN AIR
RAID.
RADIUS
BRD, BD
BOARD
GA.
GAGE
R.T.
RESILIENT TILE
BTWN
BETWEEN
GALV.
GALVANIZED
R.D.
ROOF DRAIN
BLDG
BUILDING
G.B.
GRAB BAR
REF.
REFERENCE
BLK.
BLOCK
GEN.
GENERAL
REFL.
REFLECTED
BLKG
BLOCKING
GL.
GLASS, GLAZING
REFR.
REFRIGERATOR
BM
BEAM
GND.
GROUND
REG.
REGISTER
B.M.
BENCH MARK
GR.
GRADE, GRADING
REINF.
REINFORCING
BOT
BOTTOM
GWB
GYPSUM WALL BOARD
REQ'D.
REQUIRED
BRIG
BEARING
GYP.
GYPSUM
REV
REVISION
BRZ
BRONZE
GFRC.
GLASS FIBER REINF. CONC.
R.H.
RIGHT HAND
BSMT
BASEMENT
RM
ROOM
B.U.R.
BUILT UP ROOF
H.B.
HOSE BIBB
RO
ROUGH OPENING
H.C.
HOLLOW CORE
R.O.W.
RIGHT OF WAY
CAB.
CABINET
HD.
HEAD
RCP
REFLECTED CLNG PLAN
C.B.
CATCH BASIN
HDBD.
HARDBOARD
CMNT
CEMENT
HDR
HEADER
SAM
SELF ADHERED MEMBRANE
CER.
CERAMIC
HDWD
HARDWOOD
S.
SOUTH
C.G.
CORNER GUARD
HDWR
HARDWARE
S.C.
SOLID CORE
CHAMF.
CHAMFER
HM
HOLLOW METAL
S.C.D
SEE CIVIL DRAWINGS
C.I.
CAST IRON
HORIZ
HORIZONTAL
SCHUL
SCHEDULE
C.I.P.
CAST-IN-PLACE(CONCRETE)
HR
HOUR
S.D.
STORM DRAIN
CIRC.
CIRCLE
HT
HEIGHT
SLNT
SEALANT
C.JT.
CONTROL JOINT
HTG
HEATING
SECT.
SECTION
CLG, CLNG CEILING
HVAC
HEATINGNENTILATING/
SF
SQUARE FEET
CLR
CLEAR(ANCE)
AIR CONDITIONING
SH.
SHELF
CMU
CONCRETE MASONRY UNIT
HW
HOT WATER HEATER
SHT.
SHEET
CNTR
COUNTER
SHTG
SHEATHING
C.O.
CLEAN OUT
I.D.
INSIDE DIAMETER
SIM
SIMILAR
COL
COLUMN
INCL.
INCLUDING
SL.
SLOPE
CONC
CONCRETE
INSUL
INSULATION
S.L.D
SEE LANDSCAPE DRAWINGS
CONN.
CONNECTION
INT
INTERIOR
SP
STAND PIPE
CONST.
CONSTRUCTION
INV.
INVERT
SPEC
SPECIFICATION
CONT
CONTINUOUS
SQ
SQUARE
CONTR.
CONTRACTOR
JAN.
JANITOR
S.S.
SERVICE SINK
CORR.
CORRIDOR
JST
JOIST
S.S.D
SEE STRUCTURAL DRAWINGS
CPT
CARPET
JT
JOINT
S.STL
STAINLESS STEEL
CRS.
COURSING
STD.
STANDARD
CSMT
CASEMENT
KIT.
KITCHEN
STL
STEEL
C.T.
CERAMIC TILE
KO.
KNOCKOUT
STOR.
STORAGE
CTR.
CENTER
KPL.
KICKPLATE
STRUCT'L
STRUCTURAL
CSK.
COUNTER SINK
SUSP.
SUSPENDED
CU FT
CUBIC FOOT
LAM.
LAMINATE(D)
CU YD
CUBIC YARD
LAV.
LAVATORY
T.
TREAD
L.H.
LEFT HAND
T.B.
TOWEL BAR
D/B
DESIGN BUILD
L.
LENGTH, LONG
TEL.
TELEPHONE
DEMO
DEMOLITION
L.L.
LIVE LOAD
TEMP
TEMPERED
DBL
DOUBLE
LT.
LIGHT
TERR.
TERRAllO
D.L.
DEAD LOAD
LTL.
LINTEL
TEX.
TEXTURE(D)
DETL
DETAIL
LVR.
LOUVER
T&G
TONGUE AND GROOVE
D.F.
DRINKING FOUNTAIN
THK
THICK(NESS)
D.H.
DOUBLE HUNG
MARB.
MARBLE
THRESH.
THRESHOLD
DIAG
DIAGONAL
MAS.
MASONRY
T.JT.
TOOLED JOINT
DIAM.
DIAMETER
MAX
MAXIMUM
TKBD.
TACKBOARD
DIM
DIMENSION
M.C.
MEDICINE CABINET
T.O.B.
TOP OF BRICK
DIV.
DIVISION
MECH('L)
MECHANIC(AL)
TV
TELEVISION
DN
DOWN
MED.
MEDIUM
TYP
TYPICAL
DP.
DAMPPROOFING
MEMB.
MEMBRANE
T.O.C.
TOP OF CONCRETE
DPR.
DISPENSER
MEZZ.
MEZZANINE
T.O.S.
TOP OF STL.
DR
DOOR
MFR.
MANUFACTURE(R)
DS
DOWNSPOUT
M.F.B.
MINERAL FIBER BD.
UNFIN.
UNFINISHED
D.T.
DRAIN TILE
MH.
MANHOLE
LON
UNLESS OTHERWISE NOTED
DWG
DRAWING
MIN
MINIMUM
DWR.
DRAWER
MISC
MISCELLANEOUS
VAR.
VARNISH
MTD
MOUNTED
VCT
VINYL COMPOSITION TILE
E.
EAST
MTL
METAL
VIF
VERIFY IN FIELD
EA
EACH
MULL
MULLION
VNR.
VENEER
E.I.F.S.
EXTERIOR INSULATED
VRFY
VERIFY
FINISH SYSTEM
(N)
NEW
VERT.
VERTICAL
E.JT.
EXPANSION JOINT
N.
NORTH
VEST.
VESTIBULE
ELEV
ELEVATION
N.I.C.
NOT IN CONTRACT
V.G.
VISION GRILLE
ELEC('L)
ELECTRIC(AL)
NO.
NUMBER
V.W.C.
VINYL WALL COVERING
ELEV.
ELEVATOR
NOM.
NOMINAL
ENCL.
ENCLOSE(URE)
N.T.S.
NOT TO SCALE
W.
WEST, WIDE
ENG
ENGINEER
w/
WITH
EQ
EQUAL
O.A.
OVERALL
WAB
WATERIAIR BARRIER
EQUIP
EQUIPMENT
OC
ON CENTER
W.C.
WATER CLOSET
ESC.
ESCALATOR
O.D.
OUTSIDE DIAMETER
WD
WOOD
EST.
ESTIMATE
O.F.R.D.
OVERFLOW ROOF DRAIN
W.H.
WATER HEATER
EXCAV.
EXCAVATE
OH.
OVERHEAD
W/O
WITHOUT
EXH.
EXHAUST
OPNG
OPENING
WP('G)
WATERPROOF(ING)
(E), EXIST
EXISTING
OPP
OPPOSITE
WRB
WATER RESISTANT BARRIER
EXP.
EXPANSION
O.T.S.
OPEN TO STRUCTURE
WSCT.
WAINSCOT
EXT
EXTERIOR
WT.
WEIGHT
W.W.F.
WELDED WIRE FABRIC
VICINITY MAP
r
EXISTING FOURPLEX
EDMONDS MULTIFAMILY DECKS
23615 79TH AVE W, EDMONDS, WA 98026
PERMIT SET
BUILDING CODE INFORMATION
1. THIS TENANT IMPROVEMENT IS DESIGNED IN COMPLIANCE WITH THE FOLLOWING CODES AND
REGULATIONS:
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL RESIDNETIAL CODE (IRC)
2021 WASHINGTON STATE RESIDENTIAL ENERGY CODE - (WSEC-R)
2021 INTERNATIONAL FIRE CODE (IFC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2020 NATIONAL ELECTRICAL CODE
2021 WASHINGTON STATE PLUMBING CODE
2017 ACCESSIBLE & USABLE BUILDINGS & FACILITIES
(ICC/ANSI A117.1)
WAC 51-50 WA STATE AMENDMENTS (IBC)
WAC 51.50.1100 WA STATE REGULATIONS FOR BARRIER -FREE FACILITIES
WAC 51.51 WA STATE AMENDMENTS (IRC)
WAC 51.52 WA STATE AMENDMENTS (IMC)
WAC 51.54 WA STATE AMENDMENTS (IFC)
WAC 51.56-51.57 WA STATE PLUMBING CODE & STANDARDS
WAC 51.11 WA STATE ENERGY CODE (WSEC)
WAC 51.12 WA STATE VENTILATION & INDOOR AIR QUALITY CODE
WAC 296.46B ELECTRICAL SAFETY STANDARDS, ADMINISTRATION AND INSTALLATION
��e1�►1�:L1�:1111��]I►[Hr]x.Yil:�l��[�7►
A. CONSTRUCTION TYPE: TO REMAIN
B. OCCUPANCY TYPE: TO REMAIN
C. FIRE PROTECTION: TO REMAIN
D. EXISTING BUILDING CONSTRUCTION TYPE: TO REMAIN
E. SEISMIC ZONE: D
F. BUILDING HEIGHT: TO REMAIN
SYMBOL LEGEND
COLUMN GRID LINE 0
DETAIL BUG 1 of DETAIL NUMBER
10 SHEET NUMBER
BUILDING SECTION/ 1 Ref SECTION DESIGNATION
ELEVATION 101 SHEET NUMBER
WALL SECTION 1 Ref SECTION DESIGNATION
101 SHEET NUMBER
DATUM
SCOPE OF WORK DIAGRAM
0 SITE PLAN
AO.1 J 1 " = 20'-0"
ADDITIONAL ENGERY CREDIT INFORMATION
3. WSEC IS NOT APPLICABLE IN THIS PROJECT
SEE TITLE BLOCK FOR
REVISION CLOUD REVISION. MOST RECENT
REVISIONS SHOWN CLOUDED.
REVISION NUMBER
Nv PROJECT NORTH
NORTH ARROW TRUE NORTH
1 — DRAWING NUMBER
INTERIOR ELEVATION
REFERENCE 1 A8.1 1 SHEET NUMBER
1
DRAWING NUMBER
3D VIEW REFERENCE A10 SHEET NUMBER
EROSION HAZARD AREA PER
PLANNING (HATCHED)
PROPOSED REPLACED DECK
LOCTION (RED DASHED)
LOT LINE DIMENSION FROM
PREVIOUS PERMIT #
PLN197700001-4016
EXISTING BUILDING (GREY, NIC)
WINDOW NUMBER 1 i
WALL/ PARTITION TYPE FA3 1
MATCH LINE 1 / A1.1-- VIEW REFERENCE
DECK 1 FOR UNIT 1 &2
05/08/2024
PROJECT INFORMATION
TOTAL EXISTING FLOOR AREA: 3,230 SF
TOTAL NEW FLOOR AREA: 0 SF
TOTAL NEW DECK AREA: 0 SF NEW DECK. KEEP EXISTING DECK FOOTPRINT AND DESIGN
DECK 1: 100SF
DECK 2: 130SF
DESCRIPTION:
NO SCOPE OF WORK ON EXISTING BUILDING. REBUILD EXISTING DAMAGED ENTRY DECKS WITH
EXACT SAME FOOTPRINT, DIMENSION AND DESIGN.
LEGAL DESCRIPTION
PARCEL NUMBER: 00424400000200
LEGAL DESCRIPTION:
WILLOWBROOK DIV NO 1 BLK 000-D00 - LOT 2 TGW THAT PTN LOT 3 DAF - BEG NE COR SDLOT 3 TH N70*49
46W ALG N LN SD LOT 3 FOR 59.02FT TH S01*29 40W 19.17FT TH S84*37 53E 39.46FT TH S05*22 07W 4.40FT TH
S84*37 53E 17.31 FT TO INT E LN SDLOT 3 TH N00*51 07E ALG SD E LN 9.47FT TPB SUBJ ESE PUD & GEN TEL
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
2. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY w/ THE STATE OF LOCAL
BUILDING CODE, THE LOCAL ENERGY CODE & OTHER APPLICABLE CODES, RULES & REGULATIONS OF
JURISDICTIONS HAVING AUTHORITY.
3. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT OF ANY DISCREPENCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS, OWNER
PROVIDED INFORMATION, SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, OR CODE REGULATIONS,
OR RULES OF JURISDICTIONS HAVING AUTHORITY
4. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL BECOME
FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER PROVIDED INFORMATION AND SITE CONDITIONS,
INCLUDING TAKING FIELD MEASUREMENTS AS NECCESSARY.
5. THE CONTRACTOR SHALL PAY AND SECURE & ALL GOVERNMENTAL PERMITS, FEES, LICENSES, AND
INSPECTION NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK EXCEPT FOR THE
GENERAL BUILDING PERMIT.
6. ALL DIMENSIONS ARE TO FACE OF FINISH, UNLESS OTHERWISE NOTED. CONTACT ARCHITECT FOR
CLARIFICATIONS IF NEEDED.
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
DECK 2 FOR UNIT 3&4
----------------------
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROL AND DRAINAGE Hardware and fasteners in contact with
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
DRAWING INDEX
ARCHITECTURAL
1 C E P OJ CT F R T
A0.2 TEMPORARY EROSION CONTROL MEASURES
1
A2.0 ELEVATIONS & DETAILS
APPROVED BY PLANNING
Jun 17 2024
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application, regardless
of whether such building, structure or condition is
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate
enforcement action.
Zone
CG Corner
Flag
Setbacks: Required
Actual
Front
10,
no
rhangP
Sides
0f
no
r-hangP
15'
no
Rear
change
Other
75'
no
Height
change
Like for like replacement.
PROJECT DIRECTORY
Owner: 23615 79 W LLC
23615 79TH AVE W
EDMONDS, WA 98026
Design
Architect:
General
Contractor:
Ni
1
ARCHITECTS
N
_4-_
C..)
N
J_
A.—
w Cl)
Z 00
i
O
O
J
Q
:E-rn
c
M
U
�O
U
c6
� Y
Q
c�2 Y
U
0
U
ca
c
0
U
a�
c
a)
c�
21026910
REGISTERED
� ARC TECT
YIN LU
TE OF WASHINGTON
RESUB
Jun 10 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Yining Architects
13434110th PL NE
J
o
Kirkland, WA 98034
LU M
w
P 401.837.9330
rn
Q
Q 3:
= U5
Contact: Yin Lu
i C
u7 O
O N
w
c,4
TBD
N
ca
Streetcc
N
0
Seattle, WA 981 0 0
P 206.
F 206.
City Of Edmonds
Building Department
I r
------------
Work DECKS
---
----------------
-
-----
Address 23615 79TH AVE W
---
Owner BALLINGER PARK TOWNHOME APTS
L
F_
Approved Date 6/10/2024
--
Building Official
------------------------------------
Permit Number' BLD2024-0627
preservative -treated wood shall be of
■
hot -dipped zinc galvanized steel,
ENGINEERING DIVISION I
stainless steel, silicon bronze or copper. ■
In the absence of manufacturer's
APPROVED AS NOTED I
recommendations a minimum of ASTM A 653
�¢VV U/ 06/11/2024
■
type G185 zinc -coated galvanized steel, or
✓in.e:�e
equivalent, shall be used.
■
IRC R317.3.1 IBC 2304.10.5.1 ■
APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
U)
Cn
M
U
W
O
0
in
w
LO
Co
w
4
C) Q
Q
O
�
o
Z LL
=
`"
6
w
O
II— co
0') 04
0
o
cn
U J
LO W
U
LO
0
H
Cn
O
0
a3
o
a W
ch Q
ca
o
w
a
COVER,
PROJECT
INFORMATION
AOO 1
2" x 2" WOOD/STEEL
CONTOUR LINE
FILTER FABRIC SECURED _ � (TYP)
TO 2" x 2" 14 GA \o' ANGLE TERMINAL
WIRE FABRIC EQUAL Q ��F, END UPHILL 24" TO 48"
O �JP �±� TO PREVENT FLOW
AV/ AROUND WATTLE (TYP)
CV
NATIVE BACKFILL MATERIAL
FILTER FABRIC MATERIAL IN CONTINOUS ROLLS
USE STAPLES OR WIRE RINGS TO ATTACH
FABRIC TO WIRE
2" x 2" WOOD/STEEL POSTS,
WIRE MESH FENCE
TO SUPPORT FILTER
of FABRIC
(V
co
\— BURY BOTTOM OF FILTER
N MATERIAL 8" TO 12"
6' MAX
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER
EROSION CONTROL THROUGHOUT PROJECT.
2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION
ACTIVITY.
CITY OF EDMONDS
PUBLIC WORKS
DEPARTMENT
CITY INSPECTION REQUIRED ON
ALL EROSION CONTROL METHODS
BEFORE OTHER WORK CAN BEGIN
FILTER FABRIC FENCE
FILTRATION SYSTEMS
APPROVED BY: R. ENGLISH
REVISION DATE
JANUARY 2018
STANDARD
DETAIL
ER-900
CITY OF EDMONDS
PUBLIC WORKS
DEPARTMENT
CATCH BASIN
GRATE
FILTER SOCK WITH
OVER FLOW HOLES
(TYP)
CATCH BASIN
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN
THIS APPLICATION AT ALL TIMES DURING
CONSTRUCTION PERIOD.
2. ANY SEDIMENT IN CATCH BASIN INSERT
SHALL BE REMOVED WHEN INSERT IS
ONE—THIRD FULL.
3. CITY INSPECTION REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN.
TEMPORARY
SEDIMENT TRAP
FOR CATCH BASINS
APPROVED BY: R. ENGLISH
REVISION DATE
JANUARY 2018
STANDARD
DETAIL
ER-902
\<q'of ` WATTLE
\� o' . �O�1 TRENCH, SEE NOTE 2
2" MIN -
a
i
STAGGER �,�� G• o' 5" MAX
OVERLAPS �QP O Z
(TYP) �6
2"x2"x24" UN —TREATED cV
• �� WOODEN STAKE (TYP)
PLAN VIEW
AREA AVAILABLE FOR
SEDIMENT TRAPPING
(TYP)
SPACING VARIES
SEE WATTLE SPACING
TABLE (TYP)
WATTLE (TYP)
SEE DETAIL
SECTION A —A W
WATTLE INSTALLATION ON SLOPES
NOTES:
2"x2"x24" UN —TREATED
WOODEN STAKE (TYP)
3" MIN
4" MAX
8" DIAMETER
MIN
WATTLE DETAIL
8" DIAMETER
SPACING
WATTLE
TABLE
SLOPE
MAXIMUM SPACING
1H:1V
10'-0"
2H:1 V
20'-0"
3H:1 V
30'-0"
4H:1V
40'- 0"
>4H:1V
ONE RUN ONLY
1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION.
2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS.
INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10).
3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT
UNDERCUTTING.
4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE
SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND
SURFACE.
`St. 18y-
REVISION DATE
CITY OF EDMONDS JANUARY 2018
WATTLE INSTALLATION
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
APPROVED BY: R. ENGLISH E R - 9 03
1
ARCHITECTS
W co
Z 0
00
M
(L
CD
co
J
Q
o 3:
M
6-
C
1
co
cq
� cu
V Y
CD
C6
co
O
21026910
REGI TER T
� ARC ITECT
YIN LU
TE OF WASHINGTON
0
U
cu
c
O
U
N
s=
aD
cD
RESUB
Jun 10 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
co
N
0
rn
LLJ Q
Q �
2 Cn
rn C)
� Z
Ln O
co q
M 0
CV W
CV
N
O
CB co
r) O
V J
/
U)
�
U
LLI
O
0
�
o
w
L
o
zo-
M
U)
W
Q
Q
0 No
oo W
0
cfl
p
o CD U)�
� J
rn
H
CD
.o -2 d'
ET
w W
co co Q
CV
w
TEMPORARY EROSION
CONTROL MEASURES
FLOOR PLAN GENERAL NOTES
2
A2.0
44 POST WITH 12X12
CONCRETE FOOTING,
TYP, U.O.N.
TRIBUTARY AREA
26 SF
44 POST WITH 16X16
CONCRETE FOOTING
(E) 7.5"x3.5" POST
TO REMAIN, V.I.F.
W 2X6 FRAME
AROUND
RAILING, TYP
(E) 3.5"x5.5" POE
TO REMAIN, V.I.
5
A2.0
1. DOUGLAS FIR #2 OR SIMILAR MATERIAL FOR FRAMING
2. ALL WOOD MUST BE PRESSURE -TREATED OR NATURALLY RESISTANT TO
DECAY.
3. ALL TREAT CUTS, HOLES, AND NOTCHES WITH END -CUT SOLUTION.
4. FASTENERS, HANGERS, NAILS, ETC., MUST BE STAINLESS STEEL, HOT -
DIPPED GALVANIZED, OR AS SPECIFICALLY
5. REQUIRED FOR THE SPECIFIED WOOD PRESERVATIVE USED. THE COATING
WEIGHTS FOR ZINC -COATED
6. FASTENERS TO BE IN ACCORDANCE WITH ASTM A 153.
7. USE TREK DECK FINISH OR SIMILAR ANTI -SLIP PRODUCT
1
ARCHITECTS
U
_•
W M
i
Z co
L
M
CD
co
J
Q
Q
co
M
i
7
c
_
coU cu
V Y
(U6
C
Q
�2 Y
U
0
U
CB
i
C
O
U
aD
aD
(D
21026910
REGI TER T
� ARC ITECT
YIN LU
TE OF WASHINGTON
RESUB
Jun 10 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
J
N
J
o
rn
w Q
Q �
ui
C)
Lf7
rn
Cfl
Ln O
OCV
co
CN w
N
N
O
CB co
C) O
i
N
E
Z
V J
/
U)
C
W
O
0
�
o
w
L
o
zo-
M
W
Q
Q
O
No
Z
L.L
oo
W
0
cfl
o
=
o
U)p
�
J
� rn
5
O
H
Q
.o
-2
d'
o
W
�
co Q
CV
cv
W
FLOOR PLANS
- DECK
FLOOR PLAN - DECK 1
3/4" = 1'-0"
FLOOR PLAN - DECK 2
3/4" = 1'-0"
Al ml
BUILD ON SITE HANDRAIL AND
(E) COLUMN (E) COLUMN
GUARDRAIL OR USE 12 Sim
TO REMAIN TO REMAIN
MANUFACTURED PRODUCTS
TYP.
T
ARCHITECTS
10
A2.0 i
(E) HOUSE
(E) HOUSE
`"
-A--
U
W
Z
U
0 0
EL ch
13
lE
U60 _ Y
2 p
¢�
CONCRETE
LANDING
v
c:t
1 I
L� - J 1
v
�,._____
�
21026910
REGI TERED
AR ITECT
_, _ _ l� •b�•:"°_l; • -�.� - • - - - •� • - = � - -
' - I.- -, °=1 , ' - • - -.
-
-
• -. - - - ,I•.- .1; - - - -
- I I - I s - I . •• r_ �_ �( •- 'a I-":
.- r--
J L-. ri.:- -•J r �'•,', :�_a_�,
.-
L= --�
_ ._
L� _ L- 1�-J
L,_J.'
YINLU
1•�„' -
TE OF WASHINGTON
S UA E"
•S UA E
1 DECK 1 - SIDE ELEVATION JOIST WITH DROPPED BEA 1
2
DECK 1 - SECTION
JOIST WITH DROPPED BEAM
3
DECK 1 - FRONT
E L EVAT I O
JOIST WITH DROPPED BEA
1
A2.0 3/8" = 1'-0"
A2.0
3/8" = 1'-0"
A2.0
3/8" = 1'-0"
0
U
C�
L
0
U
L
(E) COLUMN
cD
BUILD ON SITE HANDRAIL AND
TO REMAIN
GUARDRAIL OR USE
MANUFACTURED PRODUCTS
TYP. 12
2.0
10 1
A2.0
I
_ I
_
_
(E) HOUSE
(E) HOUSE
I
_ I
j
°o °o
CONCRETE LANDING `°o
2.0
°
=
_
I I
0
0
JEL_TYP
!
io
3'70 a°J
�.—:� 1
TYP ;
10"
10" /
s6pilE
4 DECK 2 - SIDE ELEVATION JOIST WITH FLUSH BEAM Q
5
DECK 2 -SECTION
JOIST WITH FLUSH BEAM 0
6
DECK 2 -FRONT
ELEVATION
JOIST WITH FLUSH BEAM
A2.0 3/8" = 1'-0"
A2.0
3/8" = 1'-0"
A2.0
3/8" = 1'-0"
RESUB
Jun 10 2024
TYPICAL DETAILS
CITYMONDS
DEVELOPMENT SERVICES
DEPARTEPART MENT
SIMPSON STRONG -TIE EPB 4X 4 WOOD TO
CONCRETE BASE
INSTALLED PER MANUF. REQUIREMENT
M 2 3/4"
J
EXISTING WALL, FLOOR LEDGER FLASHING
NOT IN SCOPE (GREY)
TREK DECK FINISH
2X8 DECK JOIST
(2) #4 EACH WAY, 3" CLEAR TO BOTTOM OF
1 /2"
HURRICAN
CLIP
TOP OF JOIST FLUSH
co
W rn
Q
3:� Q
FOOTING
WITH TOP OF BEAM
v5-
(2) ROWS LAG SCREW
LEDGER LAG SCREW
FOOTING TO BEAR ON UNDISTURBED EARTH
rn Z
DECK JOIST 2X8
N
—------Q------
— --�
°° a •°a. I;h -
°, "_; a :
=
JOIST HANGER
M M o
O C11 c'4 W
LEDGER 2X8
I
°
BEAM
-------------
"^"
�.
8D WOOD SCREW M
SIMPSON JOIST HANGER
-
- -
_d -° °•
`
JOIST
N
a, o
�2„ 16" O.C.
2"
_ :;° ;- ,_ °_ :�a, .. a_. _. •-
°
o
, , a • a' _ ^
JOIST W DROPPED BEAM
JOIST W FLUSH BEAM
;_ ° d a
—
OR PURCHASE MANUFACTURED HANDRAIL
7 LEDGER AND EXISTING HOUSE CONNECTION - TYP 8
LEDGER BOARD
SCREW PATTERN - TYP
9
FOOTING - TYP
10
HANDRAIL SECTION
- TYP 1
JOIST AND BEAM CONNECTION
0
U)
A2.0 1 1/2" = 1'-O" A2.0
1 1/2" = 1'-O"
A2.0
1 1/2" = 1'-0"
A2.0
3" = 1'-0"
2X8 DECK JOIST
E
POST AT CENTER OF BEAM JOINT
(D
of EL
6-10"
AA
RAILING ATTACHED W GUARD POST
CORROSION RESISTANT METAL
�
4X4 POST
WITH (3) #12 BY 3" LONG SCREW
/-
COLUMN CAP.
E
MIN. 1800#TENSION DEVICE
_--- ".
FOLLOW MANUFACTURER
z
° 0 0 ° ° °
°
\ \
`�"
INSTALLATION INSTRUCTION
2X8 JOIST AND RIM
\\ \\
0 0
.. 0
0
O 0
_i'"�
5/8" O.D. GALVANIZED
B L
\ \
0 0
0
0
U)
� C/)
WASHER, TYP.
NO MORE THAN 4" DIA OPENING
0
4X8 DECK BEAM
U z
W 0
,-
0 0
SECTION A —A
,_ ATTACHED BALUSTER AT TOP AND
2X4 KNEE BRACE FACE NAILED ON
J � Co
BOTTOM WITH (1) #8 WOOD SCREW
EACH SIDE OF POST AND BEAM WITH
— W cl
w
_.---"
4-16D NAILS AT EACH FACE AND
> o 0
QCR
B-B
2X4 TOP AND BOTTOM ATTACHED TO
CONNECTION, TYP.
Z L.L = No
N
GUARD POST WITH (2) 8d THREADED
O �-- � C.0o
L0
2X8 FRAMEL_:L
—T
NAILS
J Lo 0 o
�
=17
4X4 GUARD POST, NO NOTCH!
co.•, Q � w
W
F— F—
a
�° �°
1`00A THROUGH BOLT AND
WASHER
� I
ELEVATIONS & DETAILS
0
0
0
0
x0
1 GUARDRAIL CONNECTION - TYP
SECTION B-B
12
GUARDRAIL - TYP
13 KNEE BRACE -
DECK 1
A2.0 1 1/2" = 1'-0"
A2.0
1" = 1'-01,
A2.0 1" = 1'-0"