2024-10-07-Point Edwards Condo Sidewalk Replacement-RC464304 7dayOTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing CONCRETE REPORT Job Number: 24-0623 Report Number: RC464304 Permit Number: BLD2024-0795 Project: Point Edwards Condo Sidewalk Replacement Client: Point Edwards Condominiums Homeowners' Associati Address: 21 Pine Street, Edmonds Date: 10/07/2024 Inspector(s): Jonathan Andrews (WABO#: SI 02312) Description/Location: Driveway entry slab at Pine St and Pine Dr intersection, per sheet: 2.1. Inspected to approved plans. NOTE: Contractor placed reinforcement at 12"-14" on center, each way, where detail calls for 16" on center each way (#4 bar). Cadman/Heidelberg Mats did not provide batch ticket upon arrival. Rebar Verified: Yes 10/7/2024 Jonathan Andrews (Grade 60) Mfg: Nucor Placement Data Design I] Actual ❑ Batch Weights/Cubic Yard Supplier: Heidelberg Cement (Ibs/type): 450# Type: 2-L Mix Number: P4STM854 Fine Agg. (Ibs): 1521# Slump Spec: 3"-5" Coarse Agg. (Ibs/size): 1544# 3/8" Slag (Ibs): W/C Ratio Spec: 0.46 Coarse Agg. (Ibs/size): Air Spec: 3.5% - 6.5% Coarse Agg. (Ibs/size): Total Yards: 20 Fly Ash (Ibs): 120# Placed Via: Chute Water (Ibs or gal): 262# Consolidated: Yes Admixtures (specify): 3 oz. AEA Required Strength: 4000 psi @ 28 days Sampling and Testing Data Time Cubic Water Slump Air % Conc.Temp Ambient Truck Ticket ASTM C 172, C 31 Made Yards Added C 143 C 231 C 1064 Temp No. No. Cast Samples: 1-4 11:35 am 10.00 15 gal. 4.5" 5.2% 65°F 62°F 324 1491937 Weather: Clear Slump Range: 4.5" Air % Range: 5.2% Date Samples Picked Up: 10/8/2024 Initial Curing Method: Asrna c31, Exclude c31-12.1.5 Initial Curing Tmp: ASTM c31, Exclude c31-10.1.2 Comments Placed per ACI criteria. REINFORCING/PLACEMENT: Conforms: L Does Not Conform: ❑ COMPRESSIVE TEST RESULTS Fracture Type Specimen Test Field Age Size Daily Average Weight Max Load Strength (other Number Date Cure (Days) (in.) Area (Sq.ln.) Diam. (In.) (Lbs.) (Lbs.) (psi) than cone) 1 10/14/2024 7 4 x 8 12.5 3.99 8.4 37,750 3020 5 = Discarded Tested in general accordance to: ASTMC39 Iv ASTMC617 ASTMC1231 Codes to: Client ❑ Engineer ❑ Others ❑ Owner ] Contractor Technical Responsibility: ❑ Architect I Building Dept cott Hoobler, PE, Geotechnical Engineer This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 - Fax (206) 723-2221 Form No.: ADMIN-62-05 (Rev 01/24) Page 1 of 1