Loading...
2024-10-08 - Point Edwards Condo Sidewalk Replacement - GEO1570071OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing GEOTECHNICAL INSPECTION REPORT Report Number: 1570071 Description: Pin Piles Project: Point Edwards Condo Sidewalk Replacement Permit Number: BLD2024-0795 Address: 21 Pine Street, Edmonds Job Number: 24-0623 Client: Point Edwards Condominiums Homeowners' Client Address: c/o Pacific Rim Investment & Management Association 3109 Franklin Ave E, Seattle Inspector and Date Remarks Craig Bechtold, Arrived onsite as requested to observe and document the installation of galvanized 2-inch diameter L.G. schedule 80 pin piles. The piles were driven using a track hoe mounted BTI TB235ML hammer. The 10/08/2024 piles were driven to refusal, which is defined as 1-inch or less penetration in 3 seconds of continuous driving over the course of three cycles. According to the approved plans a minimum embedment depth of 20-feet is required. Please see the table below for details. Pile Number Embedment Depth Refusal 21 29' Yes 20 27.5' Yes 7 28.5' Yes 6 25.5' Yes 5 24.5' Yes 8 25' Yes 19 26' Yes 9 21.75' Yes 4 20' Yes at 19' 3 20' Yes at 19' 2 20' Yes at 18' 1 25' Yes 11 21.5' Yes 10 20' Yes at 19 17 21.5' Yes 16 21.5' Yes 12 21.5 Yes 15 20' Yes at 19.5' 18 21' Yes 13 22.5' Yes 14 22' Yes Copies to: X Client X Contractor Architect X Building Dept. Engineer Technical Responsibility: Anthony Coyne, P.E. Date: 2024.10.15 13:27:46-07'00' Anthony Coyne, P.E., Senior Engineer This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 - Fax (206) 723-2221 Form No.: ADMIN-100-01 (Rev 01105) OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Job Name: Point Edwards Condo Sidewalk Replacement Job No.: 24-0623 Report No.: 1570071 The remaining piles were driven with a pneumatic 140-pound Rhino hammer. The piles were driven to refusal, which is defined as 1-inch or less penetration in 1-minute of continuous driving over the course of three cycles. According to the approved plans a minimum embedment depth of 20-feet is required. Please see the table below for details. Pile Number Embedment Depth Penetration in final 60-Seconds Refusal 35 21 < 1 /2" Yes 33 17.5' * 2.5 minutes per inch, then 3 minutes per inch Yes *We contacted Kyle Bozick, Engineer of Record, with Pacific Engineering Technologies regarding the shallower embedment depth. He referenced the geotechnical engineering report from ZipperGeo dated October 5, 2023, which indicated decreasing depths may be acceptable in dense to very dense native soils below the fill. Pile Locations: Pile #35 is not labeled but is located below #34. Page 2 of