2024-02-12-Edgewood Condo Wall Repair-PAM460787OTTO ROSENAU & ASSOCIATES, INC.
Geotechnical Engineering, Construction Inspection & Materials Testing
PROPRIETARY ANCHOR MECHANICAL INSPECTION REPORT
Report Number: PAM460787
Job No: 24-0091
Project Name: Edgewood Condo Wall Repair Permit: BLD2023-1036
Project Address: 1110 5th Avenue South, Edmonds
Client Name: Edgewood Owners Association Inspector: Paul Kanikkeberg (WABO#: SI 01660)
Insp. Date 02/12/2024
Description / Location
5/8" TITEN HD anchors installed in existing S foundation wall of Unit 101 for bottom plate connection. Inspected to
approved plans and details.
Intended Use: Bottom plate connection
a
Building Code & Year: IBC 2018
Anchor Style: ❑ Expansion W Screw ❑ Sleeve ❑ Drop In
Anchor Size & Quantity: 5/8" (12)
ESR Number: 2713
Anchor Manufacturer: Simpson
Anchor Type: Titen HD
Hole Diameter: 5/8"
Hole Depth: 6 1/2"
Required Embedment: 6 1/2"
Anchor Length: 10"
Concrete Thickness: 6"
Concrete Strength: Existing
Base Material: W Normal Weight Concrete ❑ Lightweight Concrete
❑ CMU ❑ Brick ❑ Composite Deck
Hole Cleaning: W Compressed Air ❑ Hand Pump ❑ Vacuum Drill Bit
❑ Other:
Drill Bit (ANSI B212.15): Yes ORA Torque Wrench ID: 6119
Torque: 80 ft-lbs
Weather: Cloudy Ambient Temperature: 46
T �
Reference Standard(s) Used:
Conforms? W Yes ❑ No
Comments:
Copies to
❑d Client ./❑ Engineer ❑ Others Technical Responsibility:
❑ Owner ❑ Contractor
Jeff Rabe, Project Manager
❑d Architect .I❑ Building Dept
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this
report except in full, without written permission from our firm is strictly prohibited.