2024-02-12-Edgewood Condo Wall Repair-PAM460787OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing PROPRIETARY ANCHOR MECHANICAL INSPECTION REPORT Report Number: PAM460787 Job No: 24-0091 Project Name: Edgewood Condo Wall Repair Permit: BLD2023-1036 Project Address: 1110 5th Avenue South, Edmonds Client Name: Edgewood Owners Association Inspector: Paul Kanikkeberg (WABO#: SI 01660) Insp. Date 02/12/2024 Description / Location 5/8" TITEN HD anchors installed in existing S foundation wall of Unit 101 for bottom plate connection. Inspected to approved plans and details. Intended Use: Bottom plate connection a Building Code & Year: IBC 2018 Anchor Style: ❑ Expansion W Screw ❑ Sleeve ❑ Drop In Anchor Size & Quantity: 5/8" (12) ESR Number: 2713 Anchor Manufacturer: Simpson Anchor Type: Titen HD Hole Diameter: 5/8" Hole Depth: 6 1/2" Required Embedment: 6 1/2" Anchor Length: 10" Concrete Thickness: 6" Concrete Strength: Existing Base Material: W Normal Weight Concrete ❑ Lightweight Concrete ❑ CMU ❑ Brick ❑ Composite Deck Hole Cleaning: W Compressed Air ❑ Hand Pump ❑ Vacuum Drill Bit ❑ Other: Drill Bit (ANSI B212.15): Yes ORA Torque Wrench ID: 6119 Torque: 80 ft-lbs Weather: Cloudy Ambient Temperature: 46 T � Reference Standard(s) Used: Conforms? W Yes ❑ No Comments: Copies to ❑d Client ./❑ Engineer ❑ Others Technical Responsibility: ❑ Owner ❑ Contractor Jeff Rabe, Project Manager ❑d Architect .I❑ Building Dept This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 — Fax (206) 723-2221 Form No.: ADMIN-87-03 (Rev 01124) Page 1 of 1