REVIEWED BLD2023-1036+Energy_Calculations+8.16.2023_11.38.44_AM+37291732018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
Project:
Edgewood Condominium -Targeted Wall ftpe
�?Q1$yVS�D1110 5th Ave S E I V
101
Edmonds, WA 98020
Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
_ REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT!
BLD2023-1036...............................................
Date: 2023-08-15
Applies
Code Section
Component
Compliance Information Required In Permit
Location in
Building Department
Documentation
Documents
Notes
SCOPE
C103.1
Construction
For a tenant space (first build -out) project,
documents - General
indicate if there is no envelope scope included
in the project.
YES
C103.1
Construction
For an alteration project, indicate if there is
documents - General
no envelope scope included in the project.
C402.1.1.1
Low energy spaces
Identify low energy spaces on plans; include
calculations if applicable that demonstrate
eligibility for envelope provisions exemption
C402.1.1.2
Semi -heated spaces
Identify semi -heated spaces on plans, include
mechanical heating system type and
calculations that demonstrate eligibility for
wall insulation exemption
C402.1.1.3
Greenhouse spaces
Identify greenhouse spaces on plans; include
non -opaque assembly information and
mechanical heating system type if applicable,
that demonstrates eligibility for envelope
provisions exemption
C402.1.2
Equipment buildings
Provide building sf area, average wall and
roof U-factor, installed electrical and
mechanical equipment information and
heating setpoint restriction, that demonstrates
eligibility for envelope provisions exemption
NA
C402.1.2.1
Standalone elevator
Provide building area, average wall and roof
hoistways
U-factor, installed mechanical equipment
information and heating setpoint restriction,
that demonstrates eligibility for envelope
provisions exemption
C410.2
Walk-in cooler and
Identify walk-in cooler and freezer spaces on
freezer spaces
plans; including site assembled, site
constructed and prefabricated units
Identify warehouse cooler and freezer spaces
on plans
C101.4.1
Mixed residential &
Identify spaces with different occupancy
commercial building
requirements on plans
C503.2
Change of space
Identify on plans existing unconditioned
conditioning
spaces changing to semi -heated or conditioned
alteration
space, and existing semi -heated spaces
changing to conditioned space; provide
calculations for existing and final level of
space conditioning
Page 119
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C505.1
Change of occupancy
Identify on plans existing F, S and U-
alteration
occupancy spaces undergoing a change in
occupancy and final occupancy type
Group R spaces permitted before July 1, 2002
that are undergoing a change to a commercial
occupancy shall be identified on plans
Commercial (non -Group R) occupancy spaces
undergoing a change to Group R shall be
identified on plans
ENVELOPE PROVISIONS
YES
C103.2
Compliance
Indicate envelope thermal performance
prescriptive
C103.6.3
documentation
compliance path (prescriptive or component
C402.1.3
performance) and provide WSEC envelope
C402.1.4
compliance reports
C402.1.5
NO
If complying via component performance,
demonstrate that the Proposed Total UA is
equal to or less than the Allowable Total UA
If complying via total building performance,
provide a list of all proposed envelope
component types, areas and U-values
YES
C303.1.1
Insulation
Indicate identification mark shall be applied
Sheet A1.0
C303.1.2
identification
to all insulation materials and insulation
installed such that the mark is readily
observable during inspection
YES
C303.1.3
Fenestration product
Indicate fenestration products shall be labeled
Sheet ALL
C402.4.3
rating
with NFRC U-factor, SHGC, VT and leakage
rating, or if products do not have an NFRC
raring, indicate applicable Chapter 3 default
values
YES
C303.1.1
General insulation
Indicate installation methods, thicknesses,
Sheet ALO
C402.2.1
installation
densities and clearances to achieve the
intended R-value of all insulation materials
NA
Where two or more layers of rigid insulation
will be used, indicate that edge joints between
layers are staggered, or exception taken
C103.2
Roof assembly
Indicate R-value(s) of cavity/continuous
C402.2.1
insulation
insulation on roof sections
Indicate framing materials on roof sections
Indicate method of framing for ceilings below
vented attics and vaulted ceilings per A102.2
(std, adv)
Provide area weighted average U-factor
calculation for insulation whose thickness
varies by 1 inch or less
Indicate effective U-factors of tapered
insulation entirely above deck per A102.2.6;
include roof configuration and slope,
maximum R-value at peak and minimum R-
value at low point for all roof surfaces
Page 219
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C402.2.1.1 Skylight curb
insulation
NA
C402.2.1.2
Rooftop HVAC
equipment curbs
YES
C 103.2
C402.2.3
C402.2.4
C303.2.1
Abovelbelow grade
wall insulation
YES
YES
NA
NA
NA
C 103.2
C402.4.4
Opaque doors
NA I C402.4.4 I Garage doors
C402.2.5 Floor over outdoor or
unconditioned space
insulation
C402.2.6 Slab -on -grade floor
C303.2.1 insulation
Indicate R-values for thermal spacers and
each insulation layer, and liner system (LS)
method for metal building roofs
Indicate skylight curb insulation R-value on
roof section, if not included in skylight NFRC
rating
Indicate rooftop HVAC equipment curb
insulation R-value on roof section
Indicate R-value(s) of cavity/continuous
Sheet A2.0
insulation on wall sections
Indicate framing materials on wall sections
Sheet A2.0
Indicate method of framing for wood
Sheet A2.0
construction per A103.2 (std, int, adv)
Indicate material density category, wall weight
and heat capacity for qualifying mass walls
For qualifying ASTM C90 masonry walls,
indicate loose -fill core insulation material and
percentage of cores filled including grouted
cores, bond beams, vertical fills, headers and
any other grouted cores
Indicate method of protection of exposed
exterior basement/crawlspace wall insulation
Indicate rated U-factor or R-value (non -
swinging) on wall sections or in door
schedules - applies to doors with less than
50% glazed area
Indicate rated U-factor for sectional and tilt -
up garage doors on wall sections or in door
schedules - applies to garage doors with less
than 14% glazed area; all other garage doors
shall comply as opaque doors
Indicate R-value(s) of cavity/continuous
insulation on floor sections
Indicate framing material on floor sections
Indicate material density category and weight
of qualifying mass floors
Indicate R-value of continuous insulation on
wall section or foundation detail
Indicate insulation extends down vertically
and/or horizontally the required distance from
top of slab
Indicate method of protection of exposed
exterior slab edge insulation
Indicate R-value of continuous insulation on
wall section or foundation detail
Page 319
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
Indicate insulation extends down vertically
from top of slab and then horizontally under
the entire slab
Indicate method of protection of exposed
exterior slab edge insulation
NA
C402.2.8
Radiant heating
Indicate insulation R-value behind radiant
system insulation
panels, U-bend/headers and bottom surface of
radiantly heated floors (other than heated slab -
on -grade)
NA
C402.4.1
Vertical fenestration
Provide total gross sf area of all above grade
C502.2.1
maximum area
wall elements and rough opening sf area of all
vertical fenestration elements in the building,
for the prescriptive max allowed window -to -
wall ratio (WWR) calculation in the WSEC
envelope compliance reports; demonstrate
compliance for each space conditioning
category separately
C402.4.1.1
Increased prescriptive
Provide calculations showing that not less that
C405.2.4.1
maximum vertical
50% of the total conditioned floor area is
C502.2.1
fenestration area with
within a daylight zone; demonstrate
daylight zones and
compliance for each space conditioning
controls
category separately
Indicate in envelope plans that all lighting
fixtures located within daylight zones shall be
provided with daylight responsive controls per
Section C405.2.4.1
Indicate that the VT of vertical fenestration is
at least 1.1 times the rated SHGC or no less
than VT-0.55, whichever is greater
C402.4.1.3
Increased prescriptive
Indicate high performance U-factors and
C502.2.1
maximum vertical
SHGC values in fenestration schedules
fenestration area with
high-performance
Indicate if an area -weighted U-factor is used
glazing
for multiple fenestration elements within the
same fenestration category per Table C402.4;
provide area -weighted U-factor calculation
C402.1.5
Wall/vertical
Indicate if component performance with
fenestration target
target area adjustment will be used to account
area adjustment
for vertical fenestration area in excess of the
prescriptive maximum allowed; include target
area adjustment in WSEC envelope
compliance reports
C402.4.1
Skylight maximum
Provide total gross sf area of roof, and rough
C502.2.2
area
opening sf area of all skylight elements in the
building, for the prescriptive max allowed
skylight -to -roof ratio (SRR) calculation in the
WSEC envelope compliance reports;
demonstrate compliance for each space
conditioning category separately
Page 419
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C402.1.5.2
Roof/skylight target
Indicate if component performance with
area adjustment
target area adjustment will be used to account
for skylight area in excess of the prescriptive
maximum allowed; include target area
adjustment in WSEC envelope compliance
reports
YES
C402.4
U-factors, SHGC and
Indicate U-factors, SHGC and VT values in
Sheet A1.0
C402.4.3.4
VT for all
fenestration schedules
C303.1.3
fenestration
NA
assemblies
Indicate if an area -weighted U-factor is used
for multiple fenestration elements within the
same fenestration category per Table C402.4;
provide area -weighted U-factor calculation
YES
Indicate if values are NFRC or default; if
Default Sheet A1.0
default then specify frame type, glazing
layers, gap width, low-e coatings, gas -fill
NA
C402.4.3
Permanent shading
For each group of windows with similar
devices
orientation and overhang or permanent
projection geometry, provide projection
factor calculations (Equation C4-6) for north
and non -north orientations
C402.4.2
Single story spaces
Provide list of enclosed, single story spaces
requiring skylights
that exceed 2,500 sf; for each space identify
the space use, floor area, floor to ceiling
height, whether skylights are installed, and
any exception taken
Provide calculations for percentage of
conditioned floor area located within a toplit
daylight zone; if exception is taken for spaces
where the total floor area minus the sidelit
zone area is less than 2,500 sf, include
percentage of conditioned floor area located
within a sidelit daylight zone in calculations
Provide calculations for percentage of
skylight area in each space over 2,500 SF, OR
Provide calculations for skylight effective
aperture (Equation C4-5) for each space over
2,500 SF
Indicate haze factor of skylight glazing
material or diffuser
C410.2
Walk-in and
Indicate insulation R-value in cooler and
warehouse cooler and
freezer wall and ceiling assemblies
freezer envelope
Indicate cooler and freezer door insulation R-
value; indicate method of minimizing
infiltration (strip doors, curtains, spring -
hinged doors, etc); provide automatic door
closure (or note exception taken)
For transparent reach -in doors and fixed
windows, indicate number of glass panes
(double or triple pane); identify whether the
interstitial spaces between panes is filled with
inert gas or if panes are heat -reflective treated
glass
Page 519
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
ADDITIONAL EFFICIENCY CREDITS - ENHANCED ENVELOPE PERFORMANCE
C406.10
Enhanced envelope
To comply with additional efficiency credit,
performance
demonstrate envelope thermal performance
compliance via component performance;
provide WSEC envelope compliance reports
that demonstrate Proposed Total UA is 15%
lower than the Allowable Total UA
AIR LEAKAGE
NA
C402.5.1.1
Air barrier
Identify location and provide diagram of
construction and
continuous air barrier in plans and sections
sealing
NA
Provide details for all joints, transitions in
materials, penetrations in air barrier and note
method of sealing (caulked, gasketed, or other
approved method)
NA
C402.5.3
Rooms containing
For room(s) located within the conditioned
C402.1.3
fuel burning space
space that contain non -direct vent fuel-
C402.1.4
conditioning
burning appliances that require outdoor air for
appliances
combustion, indicate method of isolation from
the conditioned space; include sealing of
walls, floor and ceiling of room, doorway
gasketting and sealing around ductwork and
piping penetrations
NA
Indicate walls, floor and ceiling of the room
envelope are insulated to the same level
required for exterior envelope, and
combustion air ductwork that passes thru
conditioned space is insulated to at least R-8
NA
C402.5.4
Doors and access
Indicate locations of all doors and access
openings to shafts,
openings to shafts, chutes, stairways and
chutes, stairways and
elevator lobbies
elevator lobbies
NA
Indicate method of sealing of these openings
(gasketing, weatherstripping, other sealing
method); or exception taken
NA
C402.5.5
Outdoor air intakes,
Indicate locations of all stairway enclosure,
C403.7.8
exhausts and relief
elevator shaft and building pressurization
openings
relief openings, outside air intakes and
exhaust openings
NA
Note in envelope plans that all relief, outside
air intake and exhaust openings shall be
provided with dampers in accordance with
Mechanical Section C403.7.8
NA
C402.5.8
Recessed lighting in
Indicate method of sealing between light
building envelope
fixture housing and wall or ceiling
NA
Note in envelope plans that all recessed
lighting fixtures shall be IC rated and have an
air leakage rating not greater than 2 cfm per
ASTM E283 test; include these requirements
in lighting fixture schedules
C402.5.6
Loading dock seals
Indicate weather seal at cargo and loading
dock doors
Page 619
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C402.5.7
Vestibules
Indicate locations and dimensions of
vestibules for building entrances; also indicate
vestibule information for exit -only doors in
buildings where separate doors for entering
and exiting are provided
NA
Indicate locations of all building entrances and
exit -only doors provided with an air curtain in
lieu of a vestibule
Indicate exception and criteria utilized for all
building entrances and exit -only doors that do
not have a vestibule or air curtain
Indicate required performance for air curtains
installed per Exception 7
For unconditioned vestibules, indicate which
envelope assembly (interior or exterior)
complies with the requirements for a
conditioned space
C103.2
Building enclosure air
Indicate in project documents that building
C402.5.1.2C
leakage test
enclosure air leakage testing is required for
402.5.1.2.1
WSEC compliance
R402.4.1.2
Provide area calculations that account for all
six sides of the air barrier boundaries
For commercial buildings, indicate that
building enclosure air leakage testing shall be
performed per ASTM C779 (or equivalent
method approved by the code official) and the
target leakage rate is 0.25 cfm/ft2 (1.5
L/s*m2) at 0.3 in. wg (75 Pa)
If the building is mixed residential /
commercial and three stories or less above
grade plane, indicate which building enclosure
air leakage test procedure will be used for the
Group R-2 / R-3 areas (Section R402.4.1.2 or
C402.5.1.2); if per R402.4.1.2, indicate that
the target leakage rate is 5 air changes per
hour at 0.2 in. wg (50 Pa)
Include the following requirements in project
documents: (1) Submit building enclosure air
leakage test reports to jurisdiction and owner;
(2) If initial test result exceeds 0.25 cfm/ft2
(1.5 L/s*m2), indicate that inspection and all
practical corrective actions be completed and
documented in the air leakage test report; (3)
If initial test result exceeds 0.40 cfm/ft2 (2.0
L/s*m2), indicate that corrective actions shall
also include re -testing; (4) Indicate that
corrective measures and retesting must be
repeated until the test result is 0.40 cfm/ft2
(2.0 L/s*m2) or less; (4) Include air barrier
test report in project close out documentation
provided to building owner.
ADDITIONAL EFFICIENCY CREDITS - REDUCED AIR INFILTRATION
Page 719
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C406.9
Reduced air
To comply with additional efficiency credit,
infiltration
indicate in project documents that the
building enclosure air leakage test results shall
not exceed 0.17 cfm/ft2 at 0.3 in. wg (75 Pa);
all documentation requirements per C 103.2
and C402.5.1.2 apply
ALTERATIONS
C503.1
Roof alteration -
For a roof alteration where existing ceiling
C503.3.1
insulation
cavities are exposed, indicate cavities are
insulated to full depth at minimum nominal
value of R-3.0 per inch
For a roof covering replacement where
insulation is installed entirely above the roof
deck, indicate insulation complies with
requirements for new construction per Tables
C402.1.3 or C402.1.4
YES
C503.1
Wall and floor
For a wall or floor alteration (floor over
Sheet ALO
alteration - insulation
outdoor or unconditioned space) where
existing envelope cavities are exposed,
indicate cavities are insulated to full depth at
minimum nominal value of R-3.0 per inch
C503.3.2
Addition of vertical
Where the addition of new vertical
fenestration
fenestration results in a window -to -wall ratio
(WWR) exceeding the prescriptive maximum
allowed per C402.4.1, demonstrate method of
compliance (prescriptive vertical fenestration
alternate, component performance with target
area adjustment for the alteration area and
existing -to -remain areas combined, or total
building performance per C407); demonstrate
for each space conditioning category
separately
C503.3.3
Addition of skylights
Where the addition of new skylights results in
a skylight -to -roof ratio (SRR) exceeding the
prescriptive maximum allowed per C402.4.1,
demonstrate method of compliance
(component performance compliance with
target area adjustment for the alteration area
and existing -to -remain areas combined, or
total building performance per C407),
demonstrate for each space conditioning
category separately
NA
C103.2
Change in space
Indicate envelope alteration thermal
C103.6.3
conditioning or
performance compliance path (prescriptive or
C503.2
occupancy
component performance with 110%
C505.1
compliance
allowance); provide WSEC envelope
documentation
compliance reports
NA
C103.2
Change in space
If complying via total building performance
C103.6.3
conditioning or
with 110% allowance, provide a list of all
C503.2C
occupancy
proposed envelope component types, areas
505.1
compliance
and U-values
documentation
PROJECT CLOSE OUT DOCUMENTATION
Page 819
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State
Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
YES C103.6.3 Project close out Indicate in plans that project close out
documentation documentation is required including
requirements applicable calculations, WSEC envelope
compliance reports, and fenestration NFRC
rating certificates
Page 919
8/15/23, 2:22 PM https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY19mdWxseV9jb25kaXRpb251ZCU3Q3BkX2FsdGVyYXRpb24mdGZ2PXNjYl9mdWxseV9jb25kaXRp...
IIENVEMPE C MARY M _E
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: 02023 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Edgewood Condominium - Targeted Wall Repairs - 2018 WSEC
For Building Department Use: I Date' Aug 15, 2023
Project Address
11105thAve S
101
Edmonds, WA 98020
Applicant Name
Cheryl Nicodemus
Applicant Phone
206-547-7288
Applicant Email
cheryl@soltnergroup.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Group R - R2, R3 & R4 over 3 stories and all Rl
General Building Use Type(s)
Multifamily/Residential
Building Cond. Floor Area
22,122
Project Scope
Alteration
Space Conditioning Categories
Fully Conditioned
Project Cond. Floor Area
22,122
Floors Above Grade
4
Compliance Method
Compliance Method 1 - General
Envelope Project Description
Repair water damaged +/-8' high x 24' length portion of the south wall, including replacement of existing window with a new window of the same size.
Envelope
W WR/SRR
Compliance
Scope
Scope
Space Conditioning Category
Compliance Method
P Category per Cate or
UA Calculation Adjustment
Fenestration Alternates
Compliance Verification
and
Method
Alteration
Fully Conditioned
Prescriptive
29.11 % / 0%
No Calculation Adjustments allowed
No alternates selected
COMPLIES
Air Barrier
Air barrier testing not included
Air Barrier Comments
Existing building
Testing
Project Title
Edgewood Condominium - Targeted Wall Repairs - 2018 WSEC Date
Aug 15, 2023
Scope & Space Conditioning
ALTERATION - FULLY CONDITIONED Compliance Verification
�rtical
COMPLIES
Window -to -wall Ratio
29.11% Skylight -to -roof -ratio Fenestration Alternate
No alternates selected
Opaque Envelope Assemblies
Insulation R-Values
Walls
Location in Documents
Assembly ID
Assembly Location Cavity
Continuous
(% penetration)
Insulated Wall
Furring
U-Factor
Net Area (SF)
Wood -framed and other - Group R
2/A2.0
EXST
Exterior R-15
R-7.5 (< 0.04%)
173
Which insulation code target does wall comply with?: R-13 Cavity + R-7.5 CI + Any framing U-Factor Source:
U-Factor Source Description: Framing Depth: 2x4
Framing Spacing: Is this assembly exterior or interior?: Exterior
Is assembly new, upgraded or unaltered existing?: Unaltered existing assembly
Fenestration & Opaque Door Assemblies
Insulation R-Values
Vertical Fenestration
Location in Documents
Assembly ID
Assembly Location
Orientation
Shading (PF)
Fenestration
SHGC
Fenestration
U-Factor
Rough
Opening (SF)
https://waenergycodes.comlprint_project_Sumrnary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY l9mdWxseV9jb25kaXRpb251ZCU3Q3BkX2FsdGVyYXRpb24mdGZ2PXNjY l9mdWxseV9jb25kaXRpb251ZCZpZDOyMD... 1 /2
8/15/23, 2:22 PM https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjYl9mdWxseV9jb25kaXRpb251ZCU3Q3BkX2FsdGVyYXRpb24mdGZ2PXNjY19mdWxseV9jb25kaXRp...
https://waenergycodes.comlprint_project_Sunimary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY 19mdWxseV9jb25kaXRpb251ZCU3Q3BkX2FsdGVyYXRpb24mdGZ2PXNjY l9mdWxseV9jb25kaXRpb251ZCZpZDOyMD... 2/2