APPROVED BLD2024-0277+Architectural_Plan+3.1.2024_7.12.38_AM+4094663PROJECT TEAM
ABBREVIATIONS
GENERAL NOTES
PROJECT DATA
DRAWING INDEX
OWNER
SUSAN LONGLEY
16430 MARINE DRIVE
STANWOOD, WA 98292
ARCHITECT
CARLETTI ARCHITECTS, P.S.
116 E FIR ST, SUITE A
MOUNT VERNON, WA. 98273
PHONE: (360) 424-0394
FAX: (360) 424-5726
EMAIL: jennifer@carlettiarchitects.com
CONTACTS: JENNIFER PEARSON
CONTRACTOR
TOWN CONSTRUCTION & DEVELOPMENT
1818 178TH ST SW
LYNNWOOD, WA 98037
PHONE: (206) 947-8818
FAX:
EMAIL: christopherdtown®gmail.com
CONTACTS: CHRIS TOWN
SYMBOLS
' ' NORTH ARROW
1 GRID LINE
A
A-4.0 BUILDING SECTION
A WALL SECTION
-4.0
2 ADETAIL
.6.0
Alk
PROPERTY CORNER
INTERSECTION
TOP OF SUBFLOOR ELEVATION MARK
EL. 10'-10 1/2'
25.00' (NEW) SPOT ELEVATION
23.72' (EXIST.)
ROOM -NAME
_10-11 ROOM NAME / NUMBER
ODOOR MARK
OWINDOW MARK
FLOOR MATERIAL
o ADJACENCY
U
ALIGN ALIGNMENT OF ITEM
REVISION MARK
INTERIOR ELEVATION
MARKS
ABV
ABOVE
JNT
AFF
ABOVE FINISH FLOOR
AC TILE
ACOUSTICAL TILE
LVL
ACP
ACOUSTICAL CEILING PANEL
L
ACT
ACTUAL
LAV
AL
ALUMINUM
LIN
ARCH
ARCHITECTURAL
LT
A TILE
ASPHALT TILE
AVG
AVERAGE
MAR
BFF BOTTOM FINISH FLOOR
BLKG BLOCKING
BR BRICK
BOS BOTTOM OF STRUCTURE
CPT
CARPET
CLG
CEILING
GEM
CEMENT
t
CENTER LINE
C TO C
CENTER TO CENTER
CT
CERAMIC TILE
CLO
CLOSET
CW
COLD WATER
COL
COLUMN
GONG
CONCRETE
CMU
CONCRETE MASONRY UNIT
CONST
CONSTRUCTION
CONT
CONTINUOUS
COORD
COORDINATE
COR
CORRIDOR
CFM
CUBIC FEET PER MINUTE
DTL
DETAIL
DIA
DIAMETER
DIM
DIMENSION
DO
DITTO
DR
DOOR
DN
DOWN
D.S.
DOWNSPOUT
DWG
DRAWING
DF
DRINKING FOUNTAIN
EA
EACH
ELEC
ELECTRICAL
ELEV, EL
ELEVATION
EQ
EQUAL
(E) EXIST
EXISTING
FYT
EXTERIOR
FO
FRP
FIN
FAAP
FD
FE
FF
FF
FRT
FLASH
FLR
F.A.
FND
FDIC
FOIO
FCIC
GA
GALV
GAP
GL
GWB
HC
HDWE
HP
HT
HM
HOR
HB
HW
HWT
HMD
HMF
ID
INSUL
INT
MO
MFR
MATL
MAX
MECH
MTL
MIN
MUL
NAT
NOM
NA
NIC
NTS
NO. #
OC
OD
0/
OVHD
PNT
PTD
PL
P LAM
PLYWD
PT
1.
IN GENERAL, PLAN DIMENSIONS SHOWN ARE TO FACE OF STUD OR
JOINT
FACE OF CONCRETE, UNLESS OTHERWISE NOTED. DO NOT SCALE THESE
DRAWINGS, USE CALCULATED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS
LEVEL
DATUM, AND LEVELS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT
LONG, LINE
IMMEDIATELY OF ANY DISCREPANCIES.
LAVATORY
2.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO
LINOLEUM
INITIATING THE WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES.
LIGHT
3.
ALL WORK SHALL COMPLY WITH THE 2018 IRC, IFC, IPC, IMC AS AMENDED BY WASH.
STATE. PROJECT SHALL ALSO COMPLY WITH THE 2018 NREC AND THE VIACQ CODES.
MARBLE
PROJECT SHALL ALSO COMPLY W/ JURISDICTIONAL CODE AMENDMENTS BY THE LOCAL
MASONRY OPENING
AGENCY. CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY PERMITS &
MANUFACTURE
INSPECTIONS TO COMPLETE THE WORK. CONTRACTOR TO HAVE CURRENT VALID CITY
OR COUNTY BUSINESS LICENSE PRIOR TO ISSUANCE OF PERMIT, WHEN REQUIRED BY LAW.
MATERIAL
MAXIMUM
4.
ERRORS, OMISSIONS, AND DISCREPANCIES, IF ANY, SHALL BE REFERRED
MECHANICAL
TO THE ARCHITECT IMMEDIATELY FOR DIRECTION OF HOW TO PROCEED.
METAL
5.
VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THE CONTRACT BY
MINIMUM
OTHERS PROVIDE ALL BLOCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR
MULLION
DUCTS, PIPES, CONDUITS, EQUIPMENT, FIXTURES, AND CABINETS. VERIFY SIZE AND
LOCATION.
NATURAL
6.
DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN, EXCEPT
NOMINAL
UPON WRITTEN INSTRUCTIONS OF THE ARCHITECT.
NOT APPLICABLE
7.
VERIFY LOCATION OF ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO:
NOT IN THIS CONTRACT
SEWER, SEPTIC, WATER, GAS, POWER, AND TELEPHONE. CAP, MARK AND PROTECT.
NOT TO SCALE
8.
DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN, MINOR MODIFICATION
NUMBER
MAY BE REQUIRED TO SUIT THE FIELD DIMENSIONS OR CONDITIONS AND SUCH
MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK OF THE CONTRACT.
ON CENTER
9.
PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF ALL GOVERNING
OUTSIDE DIMENSION
AUTHORITIES, AT RATED PARTITIONS, FLOORS, CEILINGS, AND ROOF
OVER
LOCATIONS. ALL REQUIRED FIRE -RATED PARTITIONS SHALL BE
OVERHEAD
CONTINUOUS FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE.
10.
THE CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES, INCLUDING
PAINT
DESIGN -BUILD DOCUMENTS REQUIRED BY CONTRACT DOCUMENTS, TO VERIFY
PAINTED
SIZE, WEIGHT, POWER, LOCATION AND OTHER REQUIREMENTS AND LOCATION
OF THOSE ITEMS TO BE INSTALLED PRIOR TO COMMENCEMENT OF WORK.
PLASTER, PLATE
PLASTIC LAMINATE
11.
NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED
PLYWOOD
FOR STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE
OF OCCUPANCY. NO EXCEPTIONS.
POST -TENSIONED CONCRETE
PRESSURE -TREATED WOOD
12.
SEPERATE PERMITS ARE REQUIRED FOR PLUMBING, MECH.. ELEC., FIRE SPRINKLER,
FIRE ALARM SYSTEMS & SIGNAGE.
QT
QUARRY TILE
13.
ALL EXPOSED EXTERIOR SHEET METAL SHALL BE GALVANIZED, PRIMED AND PAINTED.
RL
RAIN LEADER
14.
ALL WOOD IN CONTACT W/ CONCRETE SHALL BE PRESSURE TREATED.
REF
REFRIGERATOR,
PRESSURE TREATED WOOD SHALL BE USED FOR WOOD MEMBERS WHICH
REFERENCE
FORM THE STRUCTURAL SUPPORT OF BALCONIES, DECKS, OR PORCHES
REINF
REINFORCING BAR
ETC. WHEN SUCH MEMBERS ARE EXPOSED TO THE WEATHER.
REV
REVISION
15.
SLOPE ALL DECKS, PATIOS. AND WALKWAYS AWAY FROM BUILDING
R
RISER. RADIUS
MINIMUM OF 1/87FT FOR POSITIVE DRAINAGE.
RM, RMS
ROOM. ROOMS
16.
PROVIDE EXPANSION JOINTS IN ALL CONCRETE SLABS AS REQUIRED
RO
ROUGH OPENING
TO PREVENT CRACKING. SAW CUT ALL SLABS AS REQ'D.
17.
PROVIDE FIREBLOCKING, DRAFTSTOPS, AND FIRESTOPS IN ATTICS, FLOORS,
SCHED
SCHEDULE
AND WALL CAVITIES AS REQUIRED PER THE IBC.
SEC
SECTION
18.
ROOF DRAINS. AND OVERFLOW DRAINS SHALL COMPLY W/ THE IPC & IBC.
FACE OF. FINISH OPENING
SHT
SHEET
AND WALL CAVITIES AS REQUIRED PER THE IBC.
FIBERGLASS REINF POLYESTERSV
SHEET VINYL
FINISH
SC
SOLID CORE
19.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
FIRE ALARM ANNUNCIATOR
SPECS
SPECIFICATIONS
WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF
SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
PANEL
SF
SQUARE FEET
CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT.
FIRE DAMPER
S & V
STAIN & VARNISH
20.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS,
FIRE EXTINGUISHER
SV
STRWY
SHEET VINYL
STAIRWAY
METHODS, TECHNIQUES. SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK.
FACTORY FINISH
STL
STEEL
21.
CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL
FINISH FLOOR
STOR
STORAGE
CHANGES DURING CONSTRUCTION. THE SET SHALL BE A PART OF THE CONTRACTOR'S
FIRE RETARDANT TREATED
CLOSE-OUT PACKAGE TO THE OWNER. CLOSE-OUT PACKAGE SHALL INCLUDE:
FLASHING
STRUCT
STRUCTURAL
SET OF SHOP DRAWINGS, PRODUCT LITERATURE. EQUIPMENT WARRANTEE MANUALS.
FLOOR
SUS(1)
SUSPENDED
22.
CONTACTOR SHALL PROVIDE SOLID BLOCKING. UNLESS NOTED OTHERWISE AS REQUIRED
FLUID -APPLIED
THRESH
THRESH
THRESHOLD
FOR NAILING OF ALL INTERIOR AND EXTERIOR TRIMS. FINISHES, AND FIXTURES. THE
FOUNDATION
T.O.
TOP OF
CONTRACTOR SHALL PROVIDE FOR ALL THE NECESSARY FRAMING AND BRACING FOR THE
FURNISHED BY OWNER.
T
TREAD, THICKNESS
INSTALLATION OF OWNER FURNISHED ITEMS SUCH AS SIGNAGE. MENU BOARDS ETC.
INSTALLED BY CONTRACTOR
TEMPERED
23.
WHERE EXISTING WORK IS DAMAGED, CUT, OR DEFACED DUE TO PERFORMANCE
FURNISHED BY OWNER,
TS
TUBE STEEL
OF NEW WORK, THE CONTRACTOR SHALL PATCH AND REPAIR SAME TO MATCH ADJOINING
INSTALLED BY OWNER
TYP
TYPICAL
SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL
BREAK LINES SUCH AS CORNERS. CEILING LINES. TOP OF BASE OR SIMILAR.
FURNISHED BY CONTRACTOR,
UNPIN
UNFINISHED
INSTALLED BY CONTRACTOR
24.
THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT
UNO
UNLESS NOTED OTHERWISE
AND MAY BE REPRODUCED ONLY WITH THE WRITTEN PERMISSION OF THE
GAUGE
UR
URINAL
ARCHITECT. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF
THE ARCHITECT.
GALVANIZED
VCT
VINYL COMPOSITION TILE
GENERATOR ALARM PANEL
VERT
VERTICAL
GLASS
VIN
VINYL
GYPSUM WALLBOARD
VR
VAPOR RETARDER
VTO
VENT TO OUTSIDE
HANDICAP
WC
WATER CLOSET
HARDWARE
WP
WATERPROOFING
HEAT PUMP
WS
WHEEL STOP
HEIGHT
W
WIDTH
HOLLOW METAL WDO WINDOW
HORIZONTAL w/ WITH
HOSE BIB WD WOOD
HOT WATER WI WROUGHT IRON
HOT WATER TANK WRGB WATER RESISTANT
HOLLOW METAL DOOR GYPSUM BOARD
HOLLOW METAL FRAME ZINC. ZINCALUME
INSIDE DIMENSION
INSULATION
INTERIOR
PERMIT FROM
STATE LABOR &
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
INDUSTRIES
PROPERTY INFORMATION
PROPERTY ADDRESS 228 2ND AVE N, UNIT 1
EDMONDS, WA 98037
BUILDING CODE 2018 IRC/ 2018 IFC
ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE- RESIDENTIAL
FIRE SPRINKLERS NONE EXISTING
FIRE ALARM
ZONING
ZONING: RM-1.5
NONE EXISTING
PARCEL #
PARCEL: 00790600000100
TWN./ RNG./ SEC.
TWN27N RNG3E BEC23 QUARTER SE
LEGAL DESCRIPTIONS
EDMONDS SUNSET VIEW, A CONDOMINIUM BLK 000 D-00 UNIT 1 TGW UND
51.86% INT IN COM AREAS & FACS DESC IN DECL RECAP NO 9011080373
& AMEND TO DECL REG UND AF NO 9012030326
BUILDING HEIGHT
EXISTING. NO CHANGE
PARKING CALCULATION
EXISTING, NO CHANGE
LOT COVERAGE
EXISTING, NO CHANGE
BUILDING CODE DATA
OCCUPANCY (R-2) - RESIDENTIAL - CONDOMINIUM (EXISTING. NO CHANGE)
CONSTRUCTION TYPE V-B (R-2)
UNIT #1 (UNIT OF WORK, EXISTING)
3 BEDROOM 2,296 SF, NO CHANGE
DECK 1 76 SF, NO CHANGE, NO WORK
DECK 2 151 SF, NO CHANGE, NO WORK
TOTAL SF 2,523 S.F., EXISTING, NO CHANGE IN USE OR S.F.
OCCUPANT LOAD/ EXIT REQUIREMENTS
ROOM
NAME
AREA
OCC.
FACTOR
OCC.
LOAD
EXITS REQ'D
RESIDENTIAL UNIT 1
2,523
200
13
>10 (2) EXIT REQ'D/ PROV.
SEE SHEET A-2.0 FOR FLOOR PLANS:
-TRAVEL DISTANCE < 125'-0' TO COMMON PATH OF TRAVEL 1006.2.1
-OVERALL EXIT ACCESS TRAVEL DISTANCE < 250'-0' FOR (R) 1017.2
-EGRESS WIDTH PER OCCUPANT SERVED 1005.3.2 (OK)
LOCATION OFF
INTERIOR REMODEL
Any fire rated assemblies that are
damaged during construction shall be
ARCHITECTURAL
A-0.0 COVER SHEET/ CODE ANALYSIS
A-2.0 DEMO/EXIST FLOOR PLAN/PROPOSED FLOOR PLAN UNIT#1
DEFERRED SUBMITTALS
-PLUMBING PERMIT/ DRAWINGS
-MECHANICAL PERMIT/ DRAWINGS
-ELECTRICAL/LIGHTING PERMIT/ DRAWINGS
SPECIAL INSPECTIONS REQUIRED
NONE
SEE HOA LETTER
FOR SCOPE OF
WORK APPROVAL
restored to original construction. 215
216
211 00
Interconnected Smoke Alarms Are A Requirement
Of This Permit In Accordance With R314.2.2
.............................................
APPROVED
Separate Plumbing Permit Required.
Please apply via MyBuildingPermit.com
PLANS MUST BE
ON JOB SITE
VICINITY MAP
110
RRom:
E
City Of Edmonds
Building Department
----------------------------
Work INTERIOR REMODEL
--------------------------------------------
-------------------------------------------
Address 228 2ND AVE N UNIT 1
-------------
Owner LONGLEY
Approved Date 03/19/2024
Building Official Er( & Carfer
Permit Number
BLD2024-0277
(CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: RID)
01 424-0394
Fax: 424-5726
6429
REG STERED
ITECT
STATE DRIWASHINGTON
AN INTERIOR REMODEL FOR:
SUSAN LONGLEY
228 2ND AVE,
UNIT #1
EDMONDS, WA
23-729
REVISIONS:
1/31/24 PERMIT SET
SHEET TITLE:
COVERSHEET
RECEIVED
Mar 04 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
JENNIFER PEARSON
PROJECT ARCHITECT:
JENNIFER PEARSON
DRAWN BY:
Pic
CHECKED BY:
11/22/23
DATE
23-729 COVERSHEET.DWG
COMPUTER FILE NAME
==_ n
COPYRIGHT 2024 CARLETTI ARCHITE0
CTS. P.S.
LEGEND:
F EXISTING WALLS, DOORS. WINDOWS TO REMAIN
_ WALLS. DOORS, CASEWORK. FIXTURES. APPLIANCES
TO BE REMOVED
® EXISTING INTERIOR SHEAR WALLS TO REMAIN, NO
WORK PROPOSED OTHER THAN TO PATCH/REPAIR
FINISH AS REQ'D
DEMO GENERAL NOTES:
1. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL WORK HAVE BEEN PREPARED USING
'ORIGINAL PERMIT DRAWINGS' PROVIDED TO THE ARCHITECT. NEITHER THE OWNER NOR THE
ARCHITECT WARRANT THESE TO BE 'AS -BUILT' DOCUMENTS. AND ACTUAL CONDITIONS MAY
VARY. THE DEMOLITION WORK INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF
THE DEMOLITION WORK AND IN NO WAY RELIEVES THE CONTRACTOR FROM PERFORMING ANY
AND ALL DEMOLITION REQUIRED.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS• MEMBER SIZES AND CONDITIONS OF THE
EXISTING BUILDING DEPICTED IN THE DRAWINGS AND NOTIFY CARLETTI ARCHITECTS OF ANY
DISCREPANCIES FOR POSSIBLE REDESIGN.
3. ALL REMOVALS AND SALVAGE, UNLESS SPECIFICALLY NOTED OR REQUESTED BY THE OWNER
SHALL BECOME THE PROPERTY OF THE CONTRACTOR. DEMOLITION MATERIAL AND DEBRIS
ACCUMULATED AS A RESULT OF DEMOLITION SHALL BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES BY THE CONTRACTOR AND
DISPOSED OF IN A LEGAL AND PROPER MANNER.
4. FURNISH• INSTALL. AND MAINTAIN IN SAFE CONDITIONS AT ALL TIMES TEMPORARY
PROTECTION REQUIRED TO ENSURE SAFETY FOR PERSONS AND PROPERTY DURING DEMOLITION
AND REMOVAL WORK.
5. FURNISH. INSTALL, AND MAINTAIN DUST COVERINGS TO PREVENT THE SPREAD OF DUST
BEYOND THE IMMEDIATE AREA WHERE DEMOLITION IS BEING PERFORMED.
6. ALL ELECTRICAL. PLUMBING AND MECHANICAL WORK (DEMOLITION AND NEW) IS TO BE
PERFORMED BY LICENSED, COMPETENT CONTRACTORS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND TEMPORARY
RELOCATION OF ALL LIFE SAFETY SYSTEMS INCLUDING FIRE/SMOKE ALARM AS REQUIRED
DURING DEMOLITION AND CONSTRUCTION PHASES.
8. ALL EXISTING WINDOWS & DOORS INTERIOR & EXTERIOR TO REMAIN ARE TO BE PROTECTED.
9. DEMOLITION OF EXISTING UTILITIES SHALL BE MADE SO THAT SERVICE TO OTHER AREAS OF
THE SPACE ARE UTILIZED BY THE OWNER OR OTHERS ARE NOT INTERRUPTED. PROVIDE
TEMPORARY UTILITIES• ISOLATION VALVES. DISCONNECTS. ETC. WHERE REQUIRED DURING
DEMOLITION AND NEW CONSTRUCTION.
10. THE CONTRACTOR IS RESPONSIBLE FOR ANY DEMOLITION THAT IS NOT SHOWN ON
DEMOLITION DRAWINGS BUT IS REQUIRED FOR NEW CONSTRUCTION.
11. SITE SHALL REMAIN CLEAN. ORDERLY. AND FREE OF ERRANT DEBRIS AT ALL TIMES. SWEEP
PAVEMENTS AND WET DEMOLITION DEBRIS AS IS NECESSARY TO INHIBIT SPREAD OF DIRT
AND DUST.
12. CONTRACTOR SHALL CHECK FOR DRY ROT OR INFESTATION. ALL ROT SHALL BE REMOVED AND
DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY CARLETTI
ARCHITECTS.
13. HOURS OF CONSTRUCTION MUST CONFORM WITH HOA REQUIREMENTS.
FLOOR PLAN LEGEND
EXISTING WALL FRAMING, PATCH AND REPAIR AS REQ'D
mmil= NEW WALL FRAMING: 2X4 WD STUDS (U.N.O.) 0 16' O.C. FRAMED TO
B.O. ROOF TRUSSES ABOVE W/ SOUND BATT INSULATION AND Y'
GWB LEVEL 5 FINISH EA. SIDE STUDS, FIELD VERIFY MATERIALS
NEEDED TO ALIGN WHEN FINISHED AT INFILL LOCATIONS
EXISTING INTERIOR SHEAR WALLS TO REMAIN, NO
WORK PROPOSED OTHER THAN TO PATCH/REPAIR
FINISH AS REQ'D
07- EXIST. 2A 10BC FIRE EXTINGUISHER
OSD SMOKE/CARBON MONOXIDE DETECTOR, ENSURE EXISTING DETECTORS
IN WORKING ORDER
+ FLOOR PLAN NOTES:
1. CONFIRM ALL ROUGH OPENINGS FOR DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
2. CONFIRM ALL FINISHES WITH OWNER PRIOR TO ORDERING.
3. DO NOT RUN ELECTRICAL CONDUIT AND GAS PIPING IN SAME STUD CAVITY
4. CONTRACTOR TO COORDINATE BUILDING ALARM/SECURITY/SOUND SYSTEM W/ OWNER PRIOR TO
GWB INSTALLATION WHERE APPLICABLE.
6. ENSURE SMOKE DETECTORS ARE IN PROPER WORKING ORDER AND REPLACE AS NEEDED.
BATTERY OPERATED SMOKE DETECTORS ARE ALLOWED IN EXISTING BUILDING WITHOUT
COMMERCIAL POWER SUCH AS THIS PROJECT. SMOKE DETECTORS ARE REQUIRED TO BE
INSTALLED:
A. IN EACH SLEEPING ROOM
B. IN A CENTRAL POINT IN A CORRIDOR/AREA THAT HAS ACCESS TO
SEPARATE SLEEPING ROOMS.
7. A CARBON MONOXIDE DETECTOR IS REQUIRED TO BE LOCATED OUTSIDE EA. SEPARATE
SLEEPING AREA.
8. COMBINATION SMOKE AND CO DETECTORS CAN BE INSTALLED AS REQUIRED FOR SMOKE
DETECTORS IF UL268 AND UL2075 LISTED.
9. BATHROOMS WHERE GWB IS REMOVED AND REPLACED. MUST BE REPLACED WITH MOISTURE
AND MOLD RESISTANT 'GREEN' BOARD.
10. SHOWER FLOORS AND WALLS (NOT GLAZED) ARE TO HAVE WATERPROOF SHOWER SYSTEM
INSTALLED THAT IS READY FOR TILING. ALL SYSTEM MATERIAL MUST BE INSTALLED,
SEALED AND FLASHED PER MANUFACTURE'S REQUIREMENTS.
11. EXISTING FLOOR ASSEMBLY:
Y4 GYPCRETE 0/
Y4 T&G PLYWOOD 0/
11%/' TJI'S 0 16' O.C. W/ R-19 BATT INSULATION 0/
Y' RC CHANNEL 0/
Y' GWB
•FIELD VERIFY AND ANY AREAS THAT ARE TO BE REPLACED MUST MEET EXISTING
CONDITIONS.'
12. ALL NEW APPLIANCES. PLUMBING FIXTURES TO BE COORDINATED WITH OWNER.
13. ALL LIGHTING, SWITCHING AND ELECTRICAL OUTLETS PER SEPARATE PERMIT,
14. AREAS OF CEILING THAT ARE REMOVED TO BE REPLACED WITH LIKE MATERIALS (GWB) AND
FINISHED TO ALIGN/ BLENDED TO MATCH WITH EXISTING CEILING.
REMOVE GAS INSERT
AND ASSOCIATED —
MATERIALS NEEDED TO
ACCOMMODATE NEW—REMO
REMOVE AREA OF----'— — — , — 7 WALL VF FOR
WALL UP TO CEILING. —"1'
COORDINATE REMAINING \ / I OPENING
INGCLRPI
\ / �'- — — _ � � OPENING UP
WALL W/ NEW VANITY r-1 — — DOOR HEIGH'
+ I I\ I
EXISTING IIII
SHEAR WALL IIII / 77
TO REMAIN
IF--�
REMOVE II — J — — — — REMOVE ARE
EXISTING L I WALL FOR N
POCKET DOOR, I I 34' DOOR
FRAME I
D HARDWARET
�I II
REMOVE NON -LOAD
BEARING WALLS AS
SHOWN, PLUMBING
FIXTURES, DOORS, I I �REMOVE PLU
CASEWORK AND I I o FIXTURES AP
FLOORING I I �l� ��% / FLOORING
REMOVE SECTION
OF NON -LOAD
BEARING WALL I I I
— — 2'-4'
'k REMOVE DOC
REMOVE SECTION REMOVE SECTION OF
OF NON -LOAD BEARING NON -LOAD BEARING WALL TO AREA OF NO
WALL TO ACCOMMODATE NEW POCKET WALL TO AC
ACCOMMODATE DOOR, VERIFY ROUGH 36' POCKET
NEW WINE COOLER OPENING W/ MANUF. TYP.
F-E- F==
REMOVE WALL,
PLUMBING FIXTURES,
APPLIANCES, I L _ _ _ I //
CASEWORK AND
FLOORING
I I i u I
I I �I II I I
REMOVE FIREPLACE, nI III
HEARTH AND II°� ��J EXISTING
SURROUNDING IL� I I SHEAR WALL
FIREPLACE MATERIALS I I I TO REMAIN
CAP NG LINE AS REQ'D
DEMOLIT ISTING FLOOR PLAN- UNIT #1
ND � � � � � Minimum 50 CFM
local exhaust fan
required
kCE ANEW BATH TUB
PER OWNER
NEW 34' DOOR
NEW FRAMELESS
GLASS SHOWER W/
36'W GLASS DOOR
EXIST. SHEAR
WALL TO RREMAIN.
PATCH/REPAIR AS
REQ'D
2X6 PLUMBING ;'
WALLS
INFILL AREA OF
WALL W/ NEW
STUDS, INSULATION
AND ALIGN NEW
GWB W/ EXISTING
PRIME/PNT
STING
ING/DINING
:A
IG
N �
EXIST. STUD N
BUNDLE/POST N
TO REMAIN,
TYP. /
VERIFY COOLERS -
OPENING
REQUIREMENTS
FOR ROUGH
FRAMING AND
FINISHING
12' OVERHANG ----
ISLAND
INFILL AREA
OF WALL W/
NEW STUDS,
INSULATION
AND ALIGN
NEW GWB W/ q
EXISTING,
PATCH/REPAIR
PRIME/PNT
0
lV
L
7S7A�DING
Y UOM
21
0
-,1 o
w
�SHOWE
� \b� NI17Y
TILE READY N
LINEAR DRAIN
4'-3.
I NICHE IN
WALL
— — —LOSET � SET
2' o• 3'-aI• 2' o•
ol
BUTLER i� I ii�G
PANTRY I PO R
2'-4? 8'-0.
NEW 32'
POCKET DOOR
ICRO
RAW[
DW
KITCHEN IIIII REF
5'-5'
RANG
W/
HOOD
® EXISTING
BEDROOM 2 -X
BALL
EXISTING NEW FLOORING/STAIR
SHEAR WALL TO TREADS
REMAIN PATCH AND
REPAIR AS REQ'D EXIST. _F17
STAIR
DN
I FE
E
EMOVE DOOR/FRAME
,ND AREA OF
ON -LOAD BEARING
/ALL TO ACCOMMODATE
EW 36' POCKET DOOR
EMOVE ALL PLUMBING
IXTURES, CASEWORK,
ILE AND FLOORING
HROUGHOUT
REMOVE
FLOORING
FROM STAIR
TREADS
EXISTING STAIR
DOWN TO EXTERIOR
DOOR AT EXTERIOR
STAIR, NO WORK
NEW 36'
POCKET DOOR
NEW PLUMBING
FIXTURES, CASEWORK
SHOWER & FLOORING
EXISTING ELEVATOR
STOPS ONLY 0
BASEMENT AND
UNIT 1
EXISTING STAIR
DOWN TO EXTERIOR
DOOR 0 GRADE
LEVEL
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
6429
DR��E�G,�jSTERED
Irk HITECT
STATE ORIWASHINGTON
AN INTERIOR REMODEL FOR:
SUSAN LONGLEY
228 2ND AVE N, UNIT #1
EDMONDS, WA 98020
Windows that are required to be
emergency escape and rescue
openings shall not be replaced with
anything less non conforming than
original construction.
23-729
REVISIONS:
2/29/24 PERMIT SET
SHEET TITLE:
DEMO -EXISTING FLOOR PLAN
PROPSOED FLOOR PLAN
EIVED
Mar 04 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
JENNFIER PEARSON
PROJECT MANAGER:
JENNIFER PEARSON
DRAWN BY:
PJC
CHECKED BY:
11/22/23
DATE
23-729 CONDO FLOOR PLAN.DWG
COMPUTER FILE NAME
A — 2 o r.1
COPYRIGHT 2024 CARLETTI ARCHITECTS. P.S.
PROPOSED FLOOR PLAN- UNIT #1
2Nb FLOOR
1/4'=1'-0' '