APPROVED BLD2024-0570+Architectural_Plan+5.1.2024_8.13.07_AM+4229119STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) ALL WORK ECT CODE GENERAL ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION. SPECIFICATIONS AND STANDARDS MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE TO FIELD ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. DESIGN LOADS CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION DEAD LOADS: OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. NSPECTION FOR ROOF 15PSF FLOOR 15 PSF CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. LIVE LOADS: DE M P L I A N E ROOF (SNOW LOAD) 25 PSF CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL COCLASSROOMS 40 PSF ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS CORRIDORS ABOVE FIRST FLOOR 100 PSF ONLY WILL NOT SATISFY THIS REQUIREMENT. ROOF DECK 60 PSF DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT STATEMENT OF SPECIAL INSPECTIONS SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL SPECIAL INSPECTIONS ARE NOT REQUIRED. ENGINEER. APPROVED PLANS MUST BE ON JOB SITE SHOP DRAWINGS SHOP DRAWINGS ARE NOT REQUIRED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR 1 #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.13101 2 1/2" SHANK 10d COMMON 0.14801 3" SHANK 12d COMMON 0.14801 3 1/4" SHANK 16d COMMON 0.16201 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.5. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF NATIVE SOIL==�=�=� FRAMING EXTENT OF GRANULAR FILL FRAMING COLUMNS STRUCTURAL STEEL P COLUMN BEARING RATED SHEATHING ON BEAM BEAM CONTINUOUS SHEAR WALL OVER SUPPORT (SEE SCHEDULE) SWX COLUMN MARK G�I` CONCRETE WALL (SEE SCHEDULE) BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUDVV HANGER MARK O SHEAR WALL (SEE SCHEDULE) FLAG NOTE NON -BEARING STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT / — �V FRAME CONN. ABBREVIATIONS (A) AB ABOVE ANCHOR BOLT HORIZ HORIZONTAL KING POST KP ALT ARCH ALTERNATE ARCHITECT BELOW KSI KIPS PER SQUARE INCH MECHANICAL MECH (B) MF MOMENT FRAME BLKG BM BLOCKING BEAM BOTTOM BETWEEN COMPLETE JOINT PENETRATION CLEAR NS NEAR SIDE ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH OC BOT BTWN OPP PL CJP CLR PLCS PSI CMU CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION PSF POUNDS PER SQUARE FOOT COL P/T POSTTENSIONED CONC PT PRESSURE TREATED REINFORCING CONN REINF CONT CONTINUOUS REQ'D REQUIRED SCHEDULE SIMILAR DBL DET DOUBLE DETAIL SCHED SIM DIM EA DIMENSION SOG SLAB ON GRADE STANDARD SHEAR WALL TOP OF CONCRETE EACH STD ELEV ELEVATION EXISTING SW EXIST TOC EXP FLR EXPANSION FLOOR TOS TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE TOW FDN FTG FOUNDATION FOOTING FAR SIDE FULL HEIGHT GLUE -LAMINATED BEAM TYP UNO FS VFY VERIFY FH VIF VERIFY IN FIELD GLB VERT VERTICAL City Of Edmonds Building Department Work DRYROT REPAIR Address 1233 OLYMPIC VIEW DR •--------------------------------------------------- Owner BLOOM EARLY ED. CTR -------------------------- Approved Date 05/22/2024 Building Official ErI & Permit Number BLD2024-0570 C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/12/24 Y Q DESIGN: BTJ DRAWN: ATD CHECK: DMT JOB NO: 24082.10 DATE: 04/12/2411 O W 1 ■ M RECEIVED May 02 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z V O LEI F_ v�N O Z) w O Z ID 5 00 0 J W >-0a Q J C Of CY— ZD W J () F_ OZ U M O 0 M to 0 LL p �Lli m W SHEET: Simi 2 53.1 ENGINEERING 1 S3.1 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 SISTER NEW 2x12 HF#2 TO EXIST JOISTS PER DETAIL 2/S3.1 AT AREA OF ROT REPAIR PHONE (425) 778-8500 FAX (425) 778-5536 APPROXIMATE AREA OF DRY ROT, TYP; REPLACE EXIST FRAMING W/ LIKE KIND P 1\� + 1y 3 S3.1 �15 M' ?'I TYPICAL FLOOR FRAMING PLAN NOTES: ��vof WAso, i H�op 1. CONTRACTOR TO PROVIDE WATERPROOFING AT ALL AREAS OF NEW FRAMING. 2. FLOOR SHEATHING SHALL BE REPLACED WITH LIKE KIND WITH 10d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES AND SHEAR WALLS AND 10" OC AT INTERMEDIATE FRAMING. FOR 45901 �¢sZ SHEATHING LAYOUT AND NAILING REFER TO DETAIL 4/S3.1. s`SI0 L EXIST 2x12 04/12/24 EXIST BEAMLLJ EXIST 2x12 @ 16" OC J Q Cam_ z G 0 m U � (n � W Lu 0 d W � � N Q C O Y Q DESIGN: BTJ DRAWN: ATD CHECK: DMT JOB NO: 24082.10 DATE: 04/1 2/24 Q CL cy— ~o RECEIV lx May 02 202 CITY OF EDMONDS DEVELOPMENT SERVICO DEPARTMENT ■ z =5 0 w Q U -:�: N o w � � w50) 0 J0Q O w� LL. w J () 00 Z Ld 0 M 0 0 N p Lli � m w D � SHEET: UPPER FLOOR FRAMING PLAN S2ml 1 SCALE: 1/4" = 1'-0" 2'-0" 0 2'-0" 4'-0" EXTENTS OF ROOF DECK BELOW 4 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/12/24 J Q Cam_ z C 0 m 07 0 re W Lu 0 d Y Q DESIGN: BTJ DRAWN: ATD CHECK: DMT JOB NO: 24082.10 DATE: 04/1 2/24 F- 0 w 1 ■ RECEIVED May 02 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0� �o () � N Z) W 00 0 > 0 0)W Z Q n 0 Z �.0cy- W J 0 Z LL. 0 M 0 0 o N O CJ o m W ! � Z SHEET: S2m2 ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" 2'-0" 0 2'-0" :� a 4'-0" C GI REPLACE EXIST RIM WITH LIKE KIND (4) 8d NAILS MINIMUM @ EA CONNECTION, TYP (2) ROWS OF 8d NAILS @ 12" OC STAGGERED EXIST BRICK VENEER BEAM PER PLAN SECTION SCALE: 1" = V-0" NOTE: ALL MEMBERS OF SOFFIT ARE 2x4 HF#2 UNO. REPLACE EXIST SHEATHING WITH LIKE KIND AT EXTENTS OF ROT SISTER NEW 2x12 HF#2 ONTO EXIST JOIST PER DETAIL 2 EXIST JOIST TO REMAIN. PROVIDE TEMP SUPPORT I I I ' I ' I _ CONT 2x4 AT MID -SPAN OF BRACE W/ (2) =rp � J4� 8D NAILS @ EA BRACE TEMPORARY 2x12 HF#2 BRACE @ 48" OC A35 CLIP EA SIDE I I (2) 1/4"0 x 6" LAG SCREWS @ EA STUD I I TEMPORARY 412 HF#2 BEAM I I TEMPORARY 46 POST (3) TOTAL EVENLY SPACED AT J O I ST A35 CLIP, EA SIDE BLOCK (3) BAYS @ 48" OC. ATTACH TO JOISTS W/ A35 CLIPS EA SIDE SECTION SCALE: 1" = V-0" 4'-0" EXISTING PARAPET; REPLACE WITH LIKE KIND AS REQUIRED EXISTING PLATES; REPLACE W/ LIKE -KIND EXISTING SHEATHING; REPLACE WITH LIKE KIND AS REQUIRED EXIST JOIST SECTION A -A ms A 2" MIN . . . . . . . . . . . . . I I I I I I A ol 1'-0" 6'-0" ol 1'-0" 8d NAILS @ 8d NAILS @ 12" OC 8d NAILS @ 3" OC 3" OC EXISTING ROOF JOIST PER PLAN; SISTER 1 3/4" x 14" LVL NOTE: 2x OR 3x BLOCKING ONLY IF STAGGER SHEATHING AS SHOWN. BLOCKED DIAPHRAGM IS SPECIFIED FRAMING MEMBERS INTERMEDIATE W/ SPACING PER PLAN FRAMING MEMBERS lo SHEATHING PANEL, TYP REPLACE SHEATHING WITH LIKE KIND AT EXTENTS OF ROT CONTINUOUS PANEL EDGES ADJACENT NAILS IN A REPLACE EXISTING BLOCKING I I I I I I I I ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP A35 CLIP @ 32" OC EXIST 8" CMU SUPPORTED WALL SECTION PANEL EDGES REPLACE EXIST JOIST I I I I—IFIF WITH LIKE KIND J L - _ _ EXIST L4x4 x 1/4 REPLACE DBL PLATE WITH LIKE KIND 5/8" 0 THRU BOLTS DIAPHRAGM BOUNDARY @ 48" OC (SHEAR WALL, BEAM, OR DRAG STRUT) SECTION SCALE: 1" = V-0" TYPICAL FLOOR/ ROOF SHEATHING DETAIL SCALE: NTS FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131"0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = V-0" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/12/24 I­_ N Q C O Y Q DESIGN: BTJ DRAWN: ATD CHECK: DMT JOB NO: 24082.10 DATE: 04/1 2/24 Q W o RECEIVED lx May 02 2024 CITY OF EDMONDS DEVELOPMENT SERVIC� DEPARTMENT cy- 0 Q F_ Z W O 0 P U -:�: N 0 W 00 Z 0 W > 0) 0 a c W J () 00 0 Z O M O O N p m � W �j SHEET: S3ml