Loading...
REVIEWED BLD2024-0583+Interior_Lighting_Summary+5.2.2024_8.58.10_AM+42325775/1/24, 9:51 AM waenergycodes.com/print_ project _summary _form. php?k=aWQ9MjU40TUmZnZpPTIzJ mN0aT0=&print=1 LIGHTING COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title LCNW Edmonds Medical Plaza Suite 111 and 207 - 2021 WSEC For Building Department Use: I Date: May 01, 2024 BLD2024-0583 RECEIVED REVIEWEDBY May 03 2024 CITY OF EDMONDS CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project Address WA Applicant Name Amanda Promisloff Applicant Phone 425-599-4467 Applicant Email apromisloff@tgbarchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 876 New Building or Project Cond. Floor Area 876 Floors Above Grade 2 General Project Types Alteration Addition Alteration LihtinScoe gg p Interior Lighting Compliance Method General Prescriptive Lighting Scope Lighting Project Description Suite 207 Demolition and remodel of suite to include storage area, staff work and breakroom Lighting Compliance Project Type Interior / Exterior both (Interior includes o h interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope parking) Adjustment Verification and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Energy Efficiency (AEC) No lighting or electrical additional energy efficiency Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included measures included in project Project Title LCNW Edmonds Medical Plaza Suite 111 and 207 - 2021 WSEC Date May 01, 2024 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Allowed Total Watts Allow (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Office Enclosed < 250 sf 104 0.74 77 Office Enclosed > 250 sf 365 0.66 241 Restroom General 39 0.63 25 Storage room 50-100 sf 61 0.38 23 Storage room 50-100 sf 190 0.38 72 Healthcare facility Corridor 1 1 69 0.71 49 Proposed Total LPD 473 Totals 487 473 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer LED 2x4 6 32 1 192 Troffer LED 2x2 10 1 27 1 1 270 Recessed downlight LED Downlight 1 11 11 Proposed Total LPD 473 https://waenergycodes.com/print_project _summary _form. php?k=aWQ9MjU40TUmZnZpPTIzJm NOaTO=&print=1 112 5/1/24, 9:51 AM waenergycodes.com/print_project _summary _form. php?k=aWQ9MjU40TUmZnZpPTIzJ mN0aT0=&print=1 Project Title LCNW Edmonds Medical Plaza Suite 111 and 207 - 2021 WSEC Date May 01, 2024 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer LED 2x4 2070, 2071, 2075 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Troffer LED 2x2 2072, 2074 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight LED Downlight 2073 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: https://waenergycodes.com/print_project _summary _form. php?k=aWQ9MjU40TUmZnZpPTIzJm NOaTO=&print=1 212