BLD2024-0268+HEATING Calculations+2.28.2024_2.14.51_PM+4090112I00A "DY-iyZ9iyZ91:3 simple mating system size: wasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information GARAGE CONVERSION TO ADU LIVING SPACE MARGO HENSON Heating System Type: o All other systems • Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" RECEIVED Design Temperature Instructions Design Temperature Difference (AT) 46 Mar 04 2024 Edmonds AT =Indoor (70 degrees) -Outdoor Design Temp CITY OF EDMONDS A- ^F Building DEVELOPMENT SERVICES DEPARTMENT Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) F 572 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 7.8 4,462 Glazing and Doors U-Factor X Area = UA Instructions u-o.Bo 0.300 125 37.50 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions R-49 0.026 572 14.87 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure1) U-Factor X Area UA Instructions R-21Intermediate 0.056 855 47.88 Floors U-Factor X Area UA Instructions No Floors above unconditioned spaces. � Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. 0.028 0� Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions No Below in � 0.303 0� --- Slab Grade this project. Slab on Grade (see Figure 1) F-Factor X Length UA Instructions 0.540 96 51.84 R-10 Perimeter Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space � 1.00 Sum of UA 152.09 Envelope Heat Load 6,996 Btu I Hour Figure 1. Sum of UA x AT Air Leakage Heat Load 2,217 Btu I Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 9,213 Btu I Hour Air leakage + envelope heat loss Building and Duct Heat Load 9,213 Btu I Hour Ducts in unconditioned space: sum of buildinq heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 11,516 Btu I Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)