Loading...
REV1 APPROVED ENG BLD2024-0268+SEWER REVISION PLAN+9.18.2024_12.46.04_PM+4508513W a w K a RESIDENCE p ONE-WAY Z CLEANOUT a WITH 45' 2' BEND AND ONE-WAY (MAX) CAP; SEE CLEANOUT STD SS-200B (TYP); SEE STD SS-200B NOT TO EXCEED 100' BETWEEN CLEANOUTS ONE-WAY CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR; SEE STD SS-2008 (SEE NOTE 5) NOTES: SITE PLAN SCALE 1" — 10' 0' 10' 20' 30' TWO-WAY CLEANOUT (W/ CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR; SEE STD SS-200C (SEE NOTE 5&6) 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT LID TO BE 12" CAST IRON CLEANOUT COVER WITH 1/2" HEX BOLTS AND A PICK HOLE. EAST JORDAN IRON WORKS PRODUCT #00366102 OR APPROVED EQUAL. 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: • IN ROADWAYS PER COE STD DWG GU-424 • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24"x6" DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP CONCRETE COLLAR 5. TWO-WAY CLEANOUT SHALL ONLY BE USED IN CITY ROW/EASEMENTS. WITH APPROVAL FROM THE CITY ENGINEER, IT SHALL BE USED IN LIEU OF A ONE-WAY CLEANOUT, IF ONE-WAY CLEANOUT CANNOT BE PHYSICALLY INSTALLED AT THE EDGE OF ROW/EASEMENT. TWO-WAY CLEANOUT SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO EDGE OF ROW/EASEMENT. 6. TWO-WAY CLEANOUTS SHALL NOT BE INSTALLED ON PRIVATE PROPERTY. REVISION DATE MARCH 2O24 CITY OF EDMONDS SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL FSt 189� APPROVED BY: R. ENGLISH SS-200A �z W � W o 12" LOCKING COVER ( a SEE NOTE 3 ON STD SS-200A w 0 END OF PIPE GRIPPER PLUG E 27061 OR APPROVED w EQUAL) a U 12"f FINISHED GRADE \/\ \ LEVOL C4 SEE NOTELING ON I STD SS-200A WATER TIGHT CAP 12" PVC SLEEVE 45' RISER 6" RISER 45' 6" WYE AND 6" CITY STUB 45' BEND 4" OR 6" SIDE SEWER 4" OR 6" GENERAL ONE-WAY CLEANOUT DETAIL SIDE SEWER CLEANOUT DETAIL AT PROPERTY LINE/CITY EASEMENT 12" LOCKING COVER 3 z SEE NOTE 3 ON STD SS-200A "w 0 W LEVELING COLLAR j ao w SEE NOTE 4 ON STD SS-200A a a 02 ASPHALT SURFACE 12"t 1 FOOT LONG 12" PVC SLEEVE 6" RISER END OF PIPE GRIPPER PLUG (CHERNE 270261 OR APPROVED EQUAL) TYPICAL ONE—WAY CLEANOUT UNDER ASPHALT OR CONCRETE NOTE: SEE COE STD SS-200A FOR ADDITIONAL REQUIREMENTS. v CITY OF EDMONDS PUBLIC WORKS DEPARTMENT FS t . 1890 ONE—WAY SEWER CLEANOUT DETAIL APPROVED BY: R. ENGLISH REVISION DATE MARCH 2O24 STANDARD DETAIL SS-200B SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LOT COVERAGE PROJECT DATA LOT AREA: EXISTING HOUSE FOOTPRINT: EXISTING GARAGE: PROPOSED NEW AREAS: TOTAL EXIST. LOT COVERAGE: 7178 SF 1535 SF 5 72 SF 0 SF 2107 SF 29.35% IMPER VIO US S URFA CE CO VERA GE EXISTING BUILDINGS EXISTING WALKS, DRIVES, PATIOS NEW AREA TOTAL NEW + REPLACED RESTORATION LIMITS TO BE DETERMINED BY CITY ENGINEERING INSPECTOR 2527 SF 1850 SF 0 SF 0 SF PROPERTY OWNER/APPLICANTS: MARGO HENSON 7019 14TH AVE. N. W. SEATTLE, WA 98117 (206) 684-6627 PROJECT DESIGNER: TOM LEREN, THE LEREN COMPANY INC. PO BOX 12863 MILL CREEK, WA 98082 (206) 954-4145 tom@lerendesign.com SITE DATA SITE ADDRESS: 23620 79TH AVE. W., EDMONDS WA 98026 PARCEL NUMBER: 00442400000501 TOTAL LOT AREA: 7,178 S.F. ZONING: RS MAXIMUM BUILDING HEIGHT: 75' SETBACKS: 10' STREET, 0' SIDE YARDS 0' REAR YARD NO CHANGE TO BLDG. HEIGHT. J �O EXISTING CONDO co w 0 EXISTING 1" METER. 1 / x NO UPGRADE ��NEEDED. 0 00 E FENCE 5.98' .4 ,� ' L=3 57 X „ P L (NO C�H% GE) NEW STO AGE SPA UNDER E ISTI ROOF GARAGE CO E SION TO LIVINGS CE PER dExisTlw LANS. d , . 1COVERED . ° ' a . BREEZEWAYco '. N I d ° a _ EXI MMING NON . d d W 'INEW CoNNECTdCO > INIETBACK I .7275 Q I a A. ° ° �: N�Nd CLEANOUT. ' RIM ~�.a374;'�'° d d EXISTING _ I O °r _. d;,s, ed. .a d RESIDENCE O I d� O ° I op a oo� d,l add I °dl.. EXISTING �O �'o.a I PLANTER NEW LATERAL TAP AT —� EXISTING CITY SEWER LINE NEW ONE-WAY CLEANOUT w/ 12" CAST IRON LAMPHOLE COVER w/ 2" HEX BOLTS AND PICK HOLE. 6" GRIPPER TWIST PLUG AND CONCRETE LEVELING COLLAR PER SS-200A AND SS-200B Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE I � M 8.91' I I NEW 1" WATER LINE 22.00, 35 O, •0 � g.L_ 0 a z'd I QJ I. d and _a.F-a�--.J.Q°I .� I IA - L ° d. N d®.III I $ I EADY I ° h �- AND ONE EV A A L ..I ° CHARGING PORTS. a Al 1 EDC17.115.050 b NEW P co.;l °AS A a1. I d I ( ()) CONNECTION POINT I ° I E 371.20' LA d ° x — — — x J d 0' _ B.S.B.L. 16.50' x S S—� 1 x x� I TYPICAL 16.5' x G, PARKING SPACES (3) PROVIDED. NEW CLEANOUT RIM @ 373.75' INSTALL NEW 54 LF 6" FIELD ADJUST PER CITY SIDE SEWER AT 2% MIN. INSPECTOR. ADS/PVC OR EQUAL. O OPTIONS MAY INCLUDE O MINIMIZING OR ELIMINATING 90'S. t� OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING — ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. SS SS J 66.7'+- CUT AND CAP EXISTING SEWER LINE. I0O W m �O- LEGAL DESCRIPTION LOT 1 OF SHORT PLAN S-2001-11 RECORDED UNDER RECORDING NUMBER 200203115001, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. SUBJECT TO ALL EASEMENTS RESTRICTIONS AND RESERVATIONS. SITUATED IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. SCOPE OF WORK: CONVERT EXISTING DETACHED GARAGE TO LIVING SPACE AND NEW 572 S.F. APARTMENT UNIT. MISCELLANEOUS NOTES THE SEWER LATERAL SHALL BE SCOPED FROM THE PROPERTY LINE TO THE SEWER MAIN BY CITY CREWS TO DETERMINE IF IT WILL NEED TO BE LINED OR REPLACED. ALL BUILDING SETBACKS, HEIGHTS, AND BUILDING LOCATIONS TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION TO ENSURE COMPLIANCE WITH COUNTY ZONING AND MUNICIPAL CODES. REVIEW ANY AND ALL APPROVAL COMMENTS FROM COUNTY PRIOR TO START OF WORK. BUILDING HEIGHT CALCULATIONS NO EXTERIOR CHANGES TO BUILDING OR BUILDING HEIGHTS. N/A 15' PRESSURE TEST SHALL BE REQUIRED ON NEW SEWER PIPE. CITY INSPECTOR SHALL BE ON SITE FOR SEWER TAP. SEWER INSPECTION REQUIRED PRIOR TO BACKFILL. SS BLD2024-0268 134.8'+- ENGINEERING DIVISION APPROVED AS NOTED 09/19/2024 APPROVAL FOR SEWER REVISION REVISION Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z N CD 0 00 z >Q o Q> U Y 2 iT F- O "0pa) J J 7 a)V 2C o co (0w z0CN,0 W — .Fa 0 W m W E 0 U + .� a>' U d Zy y d"N '6 c O in 0 0 UE �.N= aL° �s.Om@m. o z O y t o dC n oN =T 2 Na°U -V0�Ca O UU E O 0 ° °N.—fN W U.z�UN°EO OLU � LL ° w C ?� N T N D1 C C C O U U Oolu O a° m0 'Oo W - n d O o n m H a s mo E J a ° Z O Cn 1= UJ N O Z Go a Z 0 3.1 O N H w V Z Lu o Q z LJJ = w o ~ W LU O a O > a Q = a Z o N �O M O N Z W �(0LONao N N N O N L0 N CO — rn 0 N � c Qj . 0 M a - U) o E � (D m T 0 :`� > L a> U L CD 0-w CLOF .w .> .> 0 � Q �F 0 0 I 0 Z N ch .4 PROJECT NO. 240203 DESIGNED BY TL DRAWN BY TL CHECKED BY TL PERMIT SET SHEET NO. SITE PRINT DATE 9/18/2024 11:13 AM