Loading...
APPROVED PLN RESUB 2-BLD2024-0666+Site_Plan+8.27.2024_3.40.00_PM+4466314Owner: John Garbe & Susan Weller Address- 720 Cedar Street Edmonds, WA 98020 Parcel Number- 00484500300500 Jurisdiction: Edmonds, WA 98020 Zoning: RS-6 Parcel Size: Acres 0.23 Land Sqft 10,019 Height Calculations: OWNER/CONTRACTOR IS RESPONSIBLE FOR A = +101' EROSION CONTROL AND DRAINAGE B = +100.5 OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING C = +101' ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY D = +100.5' UTILITIES MAY REQUIRE A SEPERATE PERMIT. Total = 403' Avg Grade = 100.75' (403/4) Actual = 114.75' Maximum = 115.75' Structural Lot Coverage: Existing SFR & Deck: 2,362 Existing Shed (being removed): -400 New Garage: +600 Total: 2,962 (2,962/10,019) 30% Impervious Surface Calculation: Total new and/or replaced impervious 0 1 2 V=20' MAXIMUM DRIVEWAY SLOPE Inch Scale APPROVAL FOR HAND TOOLS ONLY ALLQWED 14%D IN ROW, OTHERWISE A SEPARATE - -' - - - - - - - - ,` 110' +/- ROW P�f3MIT REQUIRED The pavers to be removed. 5' min. from the back of the curb. Shed (to be T 5,- removed) A 24' B ,Proposed access I t Existing �a fromthealley , a t, Pavers 290 SF ,,7(9 180 SF I ,0, I " a7 I O� Q! 25'-QQ �G��ao, t M ---- 3 U) 15' C 600 SF D > M st L L0 t, O t f � - - -water - - � i DIRECT ROOF DRAINAGE ONTO % EXISTING , --sewer-- * SUBJECT PROPERTY - ' DOWNSPOUTS FOR GARAGE House ` SHALL NOT NEGATIVELY IMPACT NEIGHBORING PROPERTIES OR t THE ALLEY t t 2,362 SF - - t - Deck the height 12" • 1g�. ENGINEERING DIVISION APPROVED AS NOTED 780 09/13/2024 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS Exhibit A, to PermaBilt Industries FR-34 (Site Plan) Lead: 111651 - Corrected Copy 110' +/- APPROVED BY PLANNING RS-6 ;Corner Zone Flag C� Setbacks: Required Actual Sep 03 2024 Front 20 Nothing in the permit approval process shall be Sides 5' W=5' interpreted as allowing or permitting the maintenance _ _ _ _ _ _ _ _ _ _ _ _ of any currently existing illegal, nonconforming or 15' 15' unpermitted building, structure or site condition which Rear is outside the scope of the permit application, regardless of whether such building, structure or condition is Other shown on the site plan or drawing. Such building, - ' - - - - structureorconditionmay bethesubjectofaseparate enforcement action. Height 15' 14' I I I I I I o,_�I I I I I I I 1 1 n 1 d I � I � I C/) I CD �• I I I Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. I I I I I I I I I I I Center of ROW O Datum Point + 100' Fire Hydrant RESUB Aug 28 2024 C­ LLOPMET8 NDS FVI gLD2024-0666 DEVELOPMENT EVE OPMRTMENTVICES DEPARTMENT garage only.