Loading...
APPROVED ENG STM PLN RESUB3 BLD2021-0356+Civil_Plan+6.24.2022_1.58.28_PM+2953507THIS COPY FOR DEMO PURPOSES ONLY SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. EDMONDS TO WN HOMES 8029 238TH ST SW PLN20180058 APPROVED BY PLANNING DEFERRED SUBMITTAL: PRIOR TO RETAINING WALL CONSTRUCTION AT NE PROPERTY CORNER, SITE SPECIFIC CONSTRUCTION DETAILS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL, INCLUDING: 1) TOP AND BOTTOM OF WALL ELEVATIONS 2) MAX WALL HEIGHT 3) TOP OF EXISTING SEWER ELEVATION 4) ELEVATION OF ADJACENT NORTH PARKING LOT 5) DISTANCE FROM PARKING LOT TO TOP OF WALL 6) USE OF GEOGRID AND STRUCTURAL CALCS AS APPLICABLE SPECIAL INSPECTIONS: DETENTION PIPE ANCHORING .1■1■1■1■1■1■1■1■1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT yl■1■1■1■1■1■1■1■1■1.1.1.1.1.1.1.1.1.1.1.1.1.1.'Y Know what's below. Call before you dig. DIAL TOLL FREE Q AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER Approved by Fire 07/05/2022 AFM l</_-Fitterer Structure will be sprinklered, a 13D system is acceptable in each townhome. Hydrant on 238th will require a 4" Storz type fitting NOTE: A SEPARATE RIGHT—OF—WAY CONSTRUCTION PERMIT IS REQUIRED FOR ALL WORK WITHIN THE CITY RIGHT—OF—WAY. PROJECT PERMITS: BLD2021-0356 - FILL/GRADE BLD2021-0094 - COMMERCIAL BLDG BLD2021-1746 - DEMO ENG2022-0260 - ROW ENG2022-0261 - SEWER ENG2022-0236, 0237, 0238, 0239 - WATER METERS SEPARATE PERMIT REQUIRED: REMOVAL OF FUEL FILL PIPE AND TANK UNDERGROUND UTILITY NOTE REFER ALSO TO: DRAINAGE REPORT - PREPARED BY ANSTEY ENGINEERING DATED MAY 2022 UNDERGROUND UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION. THERE IS NO GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THAT THE LOCATION, SIZE OR MATERIAL ARE ACCURATE. THE CONTRACTOR SHALL EXPOSE ALL UTILITIES WHERE CROSSINGS, INTERFERENCES OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATING FOR ANY PIPE OR STRUCTURE TO DETERMINE ACTUAL LOCATION, SIZE AND MATERIAL. THE CONTRACTOR SHALL PROVIDE APPROPRIATE PROTECTION OF ALL UTILITIES. THE CONTRACTOR SHALL NOTIFY ONE —CALL AT 8-1 —1 (WASHINGTON 81 1 .COM) FOR FIELD LOCATION OF EXISTING FACILITIES BEFORE CONSTRUCTION. UTILITY PROVIDERS ELECTRICITY SNOHOMISH COUNTY P.U.D. 21018 HWY 99 EDMONDS, WA 98026 PHONE: (877) 783-1000 CONTACT: VAL BUZUNOV WATER & SEWER CITY OF EDMONDS 7110 — 210th STREET SW EDMONDS, WA 98026 PHONE: (425) 771-0235 NOTE: TRASH TO BE LOCATED INSIDE GARAGE GAS PUGET SOUND ENERGY 10606 NE 4th STREET BELLEVUE, WA 98009 PHONE: (888) 225-5773 CATV CO M CAST PHONE: (800) 934-6489 TELEPHONE CENTURYLINK PHONE: (800) 573-1311 VICINITY MAP I" = 2000' LEGAL DESCRIPTION THE SOUTH 100 FEET OF LOT 20, BLOCK 1, FRUITLAND ACRES TO LAKE BALLINGER, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 10 OF PLATS, PAGE 47, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. PARCEL NO. 00451900102000 BASIS OF BEARINGS THE MONUMENTED CENTERLINE OF 238TH ST S.W. AS THE BEARING OF N 89`07'04" W. VERTICAL DATUM NAVD 88 FOUND 2-1/2" PIPE FILLED W/ CONCRETE W/ BRASS PIN IN CASE AT THE INTERSECTION OF 238TH ST SW AND 86TH AVE W ELEVATION=431.92 EARTHWORK QUANTITIES CUT (CY) FILL (CY) ROUGH GRADING 868.85 235.21 AGGREGATE IMPORT 148.29 DETENTION TANK 50.26 TOTALS 868.85 433.76 NET (EXPORT) 435.1 SHEET INDEX SHEET TITLE 9 VICINITY MAP, SHEET INDEX, PROJECT OWNER do CONSULTANTS, UTILITY CONTACTS, LEGAL DESCRIPTION, BENCH MARK & BASIS OF BEARINGS, EARTHWORKS 2 NOTES, ABBREVIATIONS & LEGEND 3 TEMPORARY EROSION/SEDIMENTATION CONTROL PLAN 4 DEMOLITION PLAN 5 SITE DEVELOPMENT PLAN 6 GRADING & DRAINAGE PLAN 7 SEWER do WATER PLAN 8 STREET PLAN AND STORM DRAIN LINE A PLAN & PROFILE 9 STORM DRAIN LINES B & C PLAN do PROFILE 10 DETAILS 11 DETENTION TANK VENDOR DETAILS 12 AGENCY DETAILS 93 AGENCY DETAILS 14 AGENCY DETAILS 15 1 TRAFFIC CONTROL PLAN COMPLIES WITH APPLICABLE CITY STORMWATER CODE 07/08/2022 RESUB Jun 24 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0356 APPROVED FOR CONSTRUCTION CITY OF EDMONDS ENGINEERING DIVISION DATE: APPROVED AS NOTED _11�8/11 /2022 BY: CITY ENGINEERING DIVISION N O = Q N c0 (n a- O 1 m N DD Z O O N W Q m o w ' z o w w w U 07 � = Q o o cn o Q (n k:1.... U) z 0 U) w 0 z n A w `n U g0 nM z=3: Ld N N C z1:2LO Q Ln w O N Of Cn Cn Cn ww :2w O CK =F__ Cn z= 0 00 �1`0� � N C/) 0 1 0 z z w OHO :2 N :2 X 0wo0o0w ;_ o o I � � () CD C-4 �0,C�oo'00�n O N co + ao < U) z_jw�-R Ld r- = Z J O O= x Q oomo_�w N N C0 O N w �N CD CD N o i a ECD N N O o N co J 43 E -o o (1) ZC N rn a Co 3 +� a � L oj� GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2021 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS- BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. 17. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. UNDERGROUND UTILITY NOTE 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER DETENTION SYSTEM. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO (425) 744-6057 OR EMAILED TO JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON- SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. UNDERGROUND UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION. THERE IS NO GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THAT THE LOCATION, SIZE OR MATERIAL ARE ACCURATE. THE CONTRACTOR SHALL EXPOSE ALL UTILITIES WHERE CROSSINGS, INTERFERENCES OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATING FOR ANY PIPE OR STRUCTURE TO DETERMINE ACTUAL LOCATION, SIZE AND MATERIAL. THE CONTRACTOR SHALL PROVIDE APPROPRIATE PROTECTION OF ALL UTILITIES. THE CONTRACTOR SHALL NOTIFY ONE -CALL AT 8-1-1 (WASHINGTON 81 1 .COM) FOR FIELD LOCATION OF EXISTING FACILITIES BEFORE CONSTRUCTION. ABBREVIA TIONS AC ASPHALT IE INVERT ELEVATION BC BEGIN CURVE LIP GUTTER LIP BCR BEGIN CURB RETURN LP LOW POINT BEG BEGIN, BEGINNING MAX MAXIMUM BF BOTTOM OF FOOTING MIN MINIMUM BS BOTTOM OF STAIRS MH MANHOLE BVC BEGIN VERTICAL CURVE PCC POINT OF COMPOUND BW BACK OF WALK CURVATURE CB CATCH BASIN PRC POINT OF REVERSE CF CURB FACE CURVATURE CL, CENTER LINE PL, It PROPERTY LINE CLF CHAIN LINK FENCE RCP REINFORCED CONCRETE PIPE CO CLEAN OUT RW RECLAIMED WATER CONC CONCRETE S, SS SANITARY SEWER DVWY DRIVEWAY SD STORM DRAIN E ELECTRIC UTILITY STD STANDARD EC END CURVE T TELEPHONE UTILITY ECR END CURB RETURN TC TOP OF CURB EL, ELEV ELEVATION TF TOP OF FOOTING EVC END VERTICAL CURVE TG TOP OF GRATE EX, EXIST EXISTING TOE TOE OF SLOPE FF FINISHED FLOOR TOP TOP OF SLOPE FIG FINISHED GRADE TS TOP OF STAIRS, TRAFFIC SIGNAL FH FIRE HYDRANT TV COMMUNITY ANTENNA FL FLOW LINE TELEVISION FS FINISHED SURFACE TW TOP OF WALL G GAS UTILITY TYP TYPICAL GB GRADE BREAK UON UNLESS OTHERWISE NOTED GFF GARAGE FINISHED FLOOR W WATER UTILITY HGL HYDRAULIC GRADE LINE WM WATER METER HP HIGH POINT CONSTRUCTION SEQUENCE 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT (425) 771-0220, EXT. 1326. TWO DAYS (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. MAINTAIN EXIT ROUTE THROUGH PARKING AREA ON WESTERLY SIDE OF SITE TO THE EXTENT FEASIBLE. EXIT SHALL BE OPEN AT NIGHT AND ON WEEKENDS AND HOLIDAYS. 7. DEMOLISH EXISTING STRUCTURES. 8. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 9. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 10. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 11. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 12. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. LEGEND LOT LI N E SUBDIVISION BOUNDARY CENTER LINE RIGHT OF WAY EASEMENT WALL RETAINING WALL FENCE, CHAIN LINK FENCE, WOOD FENCE; WI, TUBULAR FLOW LINE, SWALE w/ FLOW DIR CONTOUR ELECTRIC LINES PSE GAS LINES TELEPHONE & CATV LINES SEWER MAIN w/ MH SEWER LATERAL WATER MAIN FIRE SUPRESSION MAIN FLOW DIRECTION WATER METER AND SERVICE FIRE HYDRANT, SUPPLY & VALVE WATER JOINTS AIR -VAC & BLOW OFF CATCH BASIN STREET LIGHT POWER & OTHER POLES w/ GUY SLOPE EXISTING PROPOSED x x O O - -55- - 55 SURFACE PIPE ------W- FLxFL MJxMJ POxPO ^ 13 Know what's below. Call before you dig. DIAL TOLL FREE AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER SURFACE PIPE 0 I[ FLxMJ 1(MJxPO )I POxFL a LED HPSV❑ LED TOP TOE BLD2021-0356 RESUB Jun 24 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT APPROVED FOR CONSTRUCTION CITY OF EDMONDS ENGINEERING DIVISION DATE: APPROVED AS NOTED BY: v/ T�ee-�8/11/2022 CITY ENGINEERING DIVISION N 0 = Q N c0 (n D_ 0 1 m N Dp Z O O � N N w a m o w z 0 W w :41� w 0] � _ Q U o � o Q a 07 z 0 U) w Qf w Q 0 0 z n ANA w `n U r- g00 ao w0) z=<N Ld N N V � z1�L0 � Q Ln w O N 0 o'(a� ww :2w OCK z = 0 00 �P� N U o I o z z w O0)O o :2 N'5 x 000 0')o I� U C° o o I � � O v O N >, () C C-4 �00c�000 ) �0)OLn 0 O Nc�+ a0 < 5 z _j Ld = Z J cq O O= x Q CID00mm�w CI) �z W � �W LLJ � z mz- < z Lu N N 0 N w Q c N � o o N N No i C, a CD 0 IL Q� N � O v o i -a w <E w o rnrn N N � I Q E N N z SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. I Ili I I I -432 1 I N 88°37'15" W I 0.0 12---�--� PROPERTY / I X I LINE I / FILTER FABRIC FENCE I I O CLEARING 428 LIMIT FILTRATION SYSTEM PER I' I IMEITRING I / I COE STD DET ER-900 I /� r 11 x I FILTER FABRIC FENCE I I I FILTRATION SYSTEM PER d TEMPORARY STOCKPILE. COE STD DET ER-900 I TO BE COVERED WITHIN / 2 HOURS. AP FORPCATCH BASINS ORARY NPER RCOE I I STD DET ER-902. APPLY TO / \ � NEW AS INSTALLED. I PROPERTY I \ I LINE 0 I I I \ o f \ 1 I a l / II I I CLEARING x LIMIT EXIST 45' EASEMENT FOR _I CIA FILTER FABRIC FENCE it INGRESS, EGRESS AND PARKING / I FILTRATION SYSTEM PER PER AFN 8510160070 PROPERTY I \ \ I COE STD DET ER-900 LINE00 II I i / jTRAP11 ITEMPORARY SEDIMENT TRAP FOR CATCH BASINS PER COESTD DET ER-902. APPLY 0 NEW AS INSTALLED. TEMPORARY SEDIMEFOR CATCH BASINSSTD DET ER-902. NEW AS INSTALLED.CLEARING I� LIMITS--------, / TEMPORARY SEDIMENT I II TRAP FOR CATCH I_ 1 I � BASINS PER COE STD DET ER-902 I� FILTER FABRIC ENCE 1 I I FILTRATION SYSTEM PER — COE STD DET E"O / li T ` C FARING LIMIT I _ EX 36;p x - - - - - N88°37' 15"W 5.2' I Ww — TEMPORARY SEDIMENT TRAP FOR CATCH BASINS PER COE STD DET ER-902. APPLY TO NEW AS INSTALLED. / I\ / I TEMPORARY SEDIMENT TRAP FOR CATCH BASINS PER COE STD DET ER-902. APPLY TO NEW AS INSTALLED. I FILTER FABRIC FENCE FILTRATION SYSTEM PER COE STD DET ER-900 / CLEARING , LIMIT .s I -STABILISED CONSTRUCTION I / PRANCE PER COE TD DET ER-901 Xq a V 00 \ _1 0 0 0 00 O'HEAD T 'T \ _... W00 ... ... . ... 977 T T SS _ TEMPORARY SEDIMENT TRAP �, I FOR CATCH BASINS PER `� \ N cv 01 �— SS COE STD DET ER-902. N tiFgp 0 - N TEMPORARY SEDIMENT TRAP V �1 - 1 FOR CATCH BASINS PER I I = 2.3Sti7 STREET SW - - - - — - - - - - - - COE CTM DET ER-902. / I TEMPORARY SEDIMENT TRAP V I ro FOR CATCH BASINS PER COE / I \STD DET ER-902. APPLY TO ` \ TEMPORARY SEDIMENTRAP T I / FOR CATCH BASINS PER COE STD DET ER-902.---.,, PUD (POLE mil I r-� LJ-U n I I I JI I I I I , I --I I NEW AS INSTALLED. r0j Sf - - - \ O'HEAD E NOTE: SEE SHEET 12 FOR TESC DETAILS. NOTE: INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. NOTE: ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY STANDARD DETAIL SD-642. NOTE: FILTER SOCKS WILL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM THE CONSTRUCTION SITE. NOTE: ORANGE PROTECTIVE BARRIER FENCING SHALL BE PLACED AT THE DRIP LINE OF TREES TO REMAIN AND AROUND AREAS PROPOSED FOR LOW IMPACT DEVELOPMENT TECHNIQUES, SUCH AS RAIN GARDENS, INFILTRATION SYSTEMS ETC., TO PROTECT THE AREA FROM COMPACTION. NOTE: ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T.5.13. NOTE: INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. II \ n II II � II � II II II PUD POLE GRAPHIC SCALE OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE • Know what's below. Call before you dig. DIAL TOLL FREE Q AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER � o(0 C I m N a0 L L- Z O O N w m W Zo w W J Q LI..I _ o v o o Q 0 Q m z 0 >R T W L U r- g00 00 0- O _ Z = N _� I NN(=n zl:2LO Q Z Ln w 0 < N v Q M V) i C 1 "= 10' E i 0 20 30 40 V') o C° o � I )-,0- �® N O I � w i �m�m ��c) a, Q� O NcD+ m N RESUB zJ w� w w`'� 1�2Z a E wo Jun 24 2022 ..J ( =� Do m m l0 0 w = CITY OF EDMONDS DEVELOPMENT SERVICES Q DEPARTMENT BLD2021-0356 z w ort:- APPROVED FOR CONSTRUCTION W CITY OF EDMONDS m z J ENGINEERING DIVISION 0 z E DATE: APPROVED AS NOTED Q z Q) "8/11/2022 w Q Z rn0 BY: Lu CL o a CITY ENGINEERING DIVISION o� z O I I -432 I I N 88,377 5,, W ��� �_ 7— REMOVE CURB 29 III\� REMOVE II - TREE SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. PANCAKE HOUSE / SS PER 8029 SS CARD ROT CT` IN PLACE r 10' I I I SANITARY &/OR STORM SEWER EX ` \ ESMT PER CO AFN 1588240 I I L 10--- / I CAP EX III EX SSMH 16-48 —+ E•yZ1101111\10111 REMOVE CURB IM v1410 EX SS EX GRAVITY WALL. / DO NOT DISTURB PROTECT I FENCE IN PLACE I / SAWCUT / GEOGRID OR PAVEMENT II / GRAVEL BACKFILL \ FULL DEPTH II \ �� I REMOVE I I I I / I//,/% TREE \ \ I I I I REMOVE I�-AM I EXISTING LT--�- �Z���` ` \ I I I I VIKING HEIGHTS III �� o \ - I III 1 AFN 200501145205 1 I o III 1 I 0 I I I III I I I ov�Vu/a �\��VIIIi� EXIST 45' EASEMENT FOR I �� % / —1 INGRESS, EGRESS AND PARKING I I 1A�11��\ �— N I I PER AFN 8510160070 / E= 1 \ I II REMOVE REMOVE EXISTING I I TREE I I CONCRETE STAIRS II 1 00 vIIIIIIIII \ \ \ I1II IIII o IiI SEPARATE PER MIT REQUIRED FOR REMOVE REMOVE FUEL PIPE AND A� ��TREE HOUSE & TANK REMOVAL REMOVE GARAGEHOUSE & REMOVE GARAGE REMOVE EXISTING CONCRETE STAIRSEXISTING —j LT & FLATWORKASPHA—� REMOVE+ III --.TREE II / I \ \ ,rT7 ---- — — I\ I ( I L� I I I I I I I I I PROTECT I _ I ( )� / \ L� I II ---� — II I\ FENCE SAWCUT PAVEMENT / L-- 1�--� �� --- II I IN PLACE 1 REMOVEFULL DEPTH I Ili EXISTING \/ I III REMOVE I I g 1 ii I I ASPH ALT;o� \51 � I III TREE �_ STORM MH TO I I e i REMOVE FUEL OIL FILL I BE RELOCATED � I 8 l �\ REMOVE CURB III\\� II/ PER DRAINAGE PIPE & 300 GALLON a REIv VE �QR6 \\ 10VE TREES TANK (TANK LOCATIO REMOVE 1 �N EI I ' �PLAN UNKNOWN) TREES a d -PROTECT P1� I� �, _ REMOVE REM 1 I/ IN PLACE 1_- i ``��� TREE Oy�l // TREE I I REMOVE I 8 I �. II//� REMOVE 11''EXISTING 8 I / / SD 1� I I' III PROTECT 0 CONCRETE ASPHALT 3��— - ��� I L (+ I I MI IN �` �f\� RETAINING WALL-"""' I o N88"37'15"W 1 /PLACE ��I�� REMOVE TREE 11 ZIPLY POLE TO BED l �� 12 .00' / RE -LOCATED BY raj 4.7I //�11.1 a 1r \ 10 I I I I I I I I II II I I I I II II L I--- I I---- JI T T � `e REMOVE DISCONNECT EXIST. WATER OTHERS. SEE STREET A1Z �1 c� PROTECT PIP I TREE SERVICE AT THE METF-R. PUD 1 POLE - --W IMPROVEMENTS. L IN PLACE �� - �����I�/ 00 TO BE REMOVED I / SAWCUT ---- E-6- �� _ o INSTALL HOSE BIB �IIT . BY OTHERS l PAVEMENT W �i� AN AVB AT THE M�ER. \ SEE NOTE 6 I \ FULL DEPTH \ --- -- —--------- i�==,1 REM O E , �/ � T /// 00 REMOVE REMOVE SIDEWALK & II SIDE ALK \ k� --_—_ DRIVEWAY. SEE I- / �. �_ —I �Q 0-0 --�- ... _ ... G � SIDEWALK I SHEET 6 FOR LIMITS. —� � T FIRF GUTTER. SEEB REMOVE CURBSHEET `� S REMOVE O HYDRANT TO S f N J i\ rill --- 6 FOR LIMITS. SAWCUT EXISTING BE �� �- �!`y,i 0, Ss — PAVEMENT ASPHALT RELOCATED _ _ CIA tiro �— N SAWCUT - --IAA- - - - - F - - FULL DEPTH / � �o V REM VE � - - - - - - - - _ s FULLDEPTH CIAMENT EXIST NG I O - -ASPH LT - \ 238th STREET SW- \ REMOVE CURB & GUTTER. SEE SHE 6 FOR LIMITS. ` \ H \ � II � PUD (POLE I r—� I I I v I --I I I I I I SID —----�--- --- of \ O'HEAD E - - - APPROVED BY PLANNING ---sD —--------- 4==11 NOTE: ORANGE PROTECTIVE BARRIER FENCING SHALL BE PLACED AT THE DRIP LINE OF TREES TO REMAIN AND AROUND AREAS PROPOSED FOR LOW IMPACT DEVELOPMENT TECHNIQUES, SUCH AS RAIN GARDENS, INFILTRATION SYSTEMS ETC., TO PROTECT THE AREA FROM COMPACTION. NOTE: EXISTING FRONTAGE IMPROVEMENTS SHALL BE MAINTAINED AS LONG AS POSSIBLE. NOTE: EXISTING FAILING, DAMAGED OR NON-ADA COMPLIANT CURB/GUTTER SHALL BE REMOVED ALONG PROPERTY FRONTAGE AS DETERMINED BY THE CITY ENGINEERING INSPECTOR. NOTE: INSTALL A HOSE SPIGOT WITH AVB ON EXISTING METER FOR WATER USE DURING CONSTRUCTION. NOTE 5: MAP EXISTING SIDE SEWER AT THE NORTHEAST CORNER OF THE SITE TO SHOW CUT SIDE SEWER TO EXISTING HOUSE AND EXISTING SIDE SEWER TO THE PANCAKE HOUSE. CO-ORDINATE NEW SIDE SEWER CARD(S) WITH THE CITY. NOTE 6: SEPARATE PERMITS TO BE OBTAINED BY RESPECTIVE UTILITY COMPANIES FOR UTILITY POLE REMOVAL/RELOCATION GRAPHIC SCALE • Know what's below. Call before you dig. DIAL TOLL FREE Q AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER � o(0 C I m N a0 L.L_ Z O O N W m w � z p W w _j : Q W _ o U o o Q 0 0 Q m z 0 QL C) W Q n T W L U r- g00 00 0- O) _ z = N H Ld N C4 zl:2LO z Q O N w � � � V) W L � Lq O z= H Q OOo0O� o I o z z w OHO o � N :2 � 0WaLd 00 v S �p1 r� p CV a, a wl vw N w v 7 p (V C, a L CD 1 "- 10, E i rn o 20 30 40 0 0 � o I to ® � 0, cn o .-. I � m w i �m� �cy)o� �, w O NcD+ QO �i fA N O � Lc) 0 O Z LLJ ---a RES U B 1�2Z J E w a (0ooa Jun 242022 oommLL.w =� CITY OF EDMONDS Q DEVELOPMENT SERVICES C� DEPARTMENT BLD2021-0356 z Q O LU o APPROVED FOR CONSTRUCTION W CITY OF EDMONDS m z J ENGINEERING DIVISION o z — Q) DATE' APPROVED AS NOTED Q Z c �8/11/2022 w Q Z c 0 BY: cr CL w o a CITY ENGINEERING DIVISION o_j SD W T G SS SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. /—------------------- - NW�R&V1LY -- �`I RETAINING WALL W P�A�11�ER W I I 10' I W W PVN7R W W W *11 1 W I I L � II W I I I y I I I I WWWW WWW III IIFI ~YQ I� IST 45 EASEMENT FOR NEW BUILDING w/ 4 w Ow RESIDENTIAL UNITS IIIIII >[ifwPER INGRESS, EGRESS AND PARKING AFN 8510150070 I W IIII III � ZwQ J W I I of o O w I GAS, PHONE, T* � O U W I I I I SEPARATE PLAN I a W I & PERMIT I I SSMH 10' &WER ASEMENT SANITARY &/OR STORM SEWER ESMT PER AFN 1588240 EXIST. WOOD FENCE EXIST. GRAVITY RETAINING WALL DEFERRED SUBMITTAL I REQUIRED PRIOR TO WALL CONSTRUCTION - I SEE SHEET 1 FOR REQUIREMENTS W EXISTING ASP LT I I I I I PARKING & DRIVEWAY AC I I I I I i i W REPAIR W I AIC1A_-_�p_i SEE DRAINAGE PLAN I I NWCB I I f — I 3 Y UNIT WAFTER LINES N & J i w IT I WP NT R W W I U II I I I I EXIST CONTROL I I I-==1 EX CB wi I li II STRUCTURE z II II I I J I L__II I W EC W W W I PERMEABLE 4 NEW WATER PAVERS— -- METERS NEW CB - W TYPFyo 2 I /" _ W W EC L ER EXIST, 3� �� ---- SO L�N� � W \ SSMHI p ri RI ANVR i n v °• a a• a. p. d °..°2'5. a.,0 d.a .a• ! ° ad p SWAY. p a tl a a s . p :. d SD LINE C ' '° ��-- •a ' A. d'' •d ° p d v •gy p.': d 'p. ° 'a DRIVEWAY. •d r.. , c p °p TPO ° pd• '•d ° ..p .d A .° ° \ d,p . . . . 7. .. W W W W .-�.:. 4 d NEWI W W EXIST SIDEWALK a p p . W PLANTER � � .d " 4 � � � � � � � ... � .. � � �_ . p . EXIST SIDEWALK I .y °. d a.. .'.° ... ... ... ... EX MAIL B XE & GUTTER NEW CB` ' NECURB / "a w SS _ EX 4" W STRIPE J i ,� i & GUTTER � z EX. CURB v>� EXIST EX CB 4 & GUTTER NEW CB REPAIR NEW CURB & G �r�'`'�SS — ,, / SSM H p & GUTTER \ �j o—- ' EXISTING ASPHALT ROAD � ----� - —may - — AC w `y REPAIR I 238th STREET SW XU (� \ w IU / EX EP EX 4" WHITE STRIPE EX EP EXIST SIDEWALK SD-- _ - _- — I � DIRT DIRT DIRT rn EX CB EX CB I r— I I I I I SEE SHEET • FOR 1 IMPROVEMENTS EXISTING ASPHALT ROAD )IRT GRAPHIC SCALE • Know what's below. Call before you dig. DIAL TOLL FREE AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER � o(0 C I m N a0 L L- Z O O N W m w z p W w Q W 0 0 0 N cl Q (%) C) Q m n T W L U r- g00 00 0- O _ Z = N H Ld N C4 zl:2L0 Q _ w O�N v AMU),,. C 07 W IL J � Lq O Z = H Q OOo0O� 0 I 0 Z Z w O0)O D :2 N :2 � 000 CL WOOW 1 "= 10' 40 RESUB Jun 24 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0356 APPROVED FOR CONSTRUCTION CITY OF EDMONDS I m ENGINEERING DIVISION 0 DATE: APPROVED AS NOTED CL BY: ,-e-�8/11 /2022 Ljj cr CITY ENGINEERING DIVISION D_ E 00 r7 0 O O + 17 � ® rn cn o .-. I c w ���00 �cy)oL �, c) w O OO �i fn N O LC)C' O U O ZwL;j W 1�2Z J w a NHOQ rn� c002Q� oo m m lL w v � I cj °E' Z o W L 15 o� v (V LLJ W �z J � mz— E-6 � � c z Q -z rn0 L-j 3 o a o� SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. / I � � I I I I I I I I � R o CONSTRUCT VERTICAL <" `�• I I / CUB PER COE STD DEf TR-521 I DEFERRED SUBMITTAL REQUIRED PRIOR TO v / � 0 2 �r'� CONRULL DRAT CONSTRUCLSEYSTONE, / I WALL CONSTRUCTION - - STCT WAI EQUAL, GRAVITY WALL I �' � c� _ PER DETAIL SHEET 10 , I SEE SHEET 1 FOR REQUIREMENTS � N 88°37`15' 356 TC 12AIl0 43 9 W�FC 0 0 0 0 0 o � sp I I I 4`3 . p9 F C I I I < CONSTRUCT TY E ; II d g f� `• "PARALLEL B" /CURB I 1.090 ° - `� ?' ~ ` RAMP PER W DOT STD ' r—�I INSTALL NDS 4" ° of 3 `':- ' I I ATR UM GRATE, I B `�3 4S T - /PLAN F-40.12-03 I mil ° al. W - Ge 9S FCC f .,• l I I II PART #75 0 I .4 I J 427.32 FL o Al. ° 4 3 S 28 TC I s( 422 00 IEy/ a I I SANITARY &/OR 4.DS ° STORM SEWER ESMT PER AFN CONSTRUCT CURB & P °.0 0 ) I '° 1588240 LO a I ° , a GUTTER PER COE I� II . %'� MIN . ' ° STD DET TR-520 ' °A. I II I d �/Fc C I ° �a I N I \ II 35 LF-4" PVC ° a I .° CIRCULAR GRATE ° A. I p� TC � ,n l® @ 2% MIN I. PER WSDOT STD FC • � � I � PLAN B-30.80-01 . CONSTRUCT 4" DS o I ° �� / I I SEE SHEET 9. / If . { ' ' .I 2' I AC ON 4" CSTC I ° a , IT I CONSTRUCT 4" �I i : ` 5 5 - ° THICK CONCRETE I li 1 . ° ° I ° o I j WALKWAY ° '4 Q a I EXIST 45 EASEMENT FOR I I 1 I ° —1 INGRESS, EGRESS AND PARKING _ I" 76 LF-4" PVC i cp I ' ° I — PER AFN 8510160070 I p 2% MIN i it CIA 11 I of d • • ' QI' A 1 cy)- °1 r-jl .. °d Icn SD LINE C .'I I II i ° ° dl ° 1: SEE SHEET 9 1 I 43 I, d I II v p d v a 1 CONSTVUCT CURB & C "I DS LL I 1 I' °'d I GUTT PER COE L o I r II I • �. ' ° °I • �1 60 o III I - 1 STD ET TR-520 I ° 80 SRPEP A , DETENTION TANK. SEE I CONSTRUCT VERTICAL ATCH BASIN TYPE I / it I ''I .. 2 SHEETS 9 & 10. I I CURB PER COE STD PER COE STD I . d II 27� . G0 I DET TR-521 /pET SD-303 CB4 I " I n T�� °' I� I G #D I CONSTRUCT V 432.46 TC z II OT EXCEED ED 3-FT IN NALL : °4 a 4 ,1 II "� 4 AC ON 431.96 TG I a �: I /¶ I LV a --CIRCULAR 1 h� �� 4" CSTC '��o, / 429.46 IE '� •� d ' LAR GRATE I�� IIII EI4HT FIR M ORIGINAL �� - ° :GB ��° \ PER WSDOT STD I ��pc�h0 ���� CONSTRUCT VERTICAL :�� �1- RADE � pa I I 'I �•.° - 'I PLAN B-30.80-01. 1 7.2% �` CURB PER COE STD I .dI 1• Ia ° ° a ° SEE SHEET 9. DET TR-521 I CONSTRUCT 4" I i o I o 19 LF-12' , I THICK CONCRETE i II II ;d :o ° ..1 I a li-- I , d° / i_ ! I ' CPEP @ 5.1 % �.... L I !— it d N W CONTROL �CB5 ICT 1'S RUCTURE & . I \ C3 I�..I 0 — I $ T NK MOD. SEE P RMEA LE PAVERS ° ° ° — — ---- I I' PER DETAI HEET 10 1% D AIL SHEET 10. I 1 '`� N a �I-- ;D �s3Q 23 T a d E ELE N o °.- - - — SD LINE C ° ° i ►i SEE SHEET 9 \ / d°' ° .�^v .° a: e. ',d1 ° ICI.• N All - NSTALL NDS 864, 5 '�\ - ° �) E. SHEET .9. c'° a' •a ° I `-=' +— CONCRET T POL I _ _ _ _ PRO SERIES CHANNEL - - - - - - _ _ _ � T� _ _ _ E - ... - ... SI.DET ... DRAIN, OR EQUAL... / O'HEAD T 2b' Oh .. ___W PRO D I.N 426.21 FS 424.45 FS 17 LF-12» .... I CPEP @ LOI — T 2 \ I CB # 1 -278 �I I \ \ 427.2 IE N N I ��-•!% —� SS— �_ I N SEE SHEET 8 FOR `\ \R0 VEMENTS W W . REFE TO LANDSCAPE SEE SHEET 8 FOR RW lMP VEMEN \ \ PLAN FORTWA-E RESTORATION AS— \ \ \ PAVERS ARE NOT LOCATED AROUND I \ \ \\ \\ CONTROLSTRUCTURE ` \ I \ I / \ \ \ \ \ \ SD_ \-SD— - I I I I II I GRAPHIC SCALE 1 "= 10' 0 10 20 30 40 SURFACE AREA (SF) STORMWATER MANAGEMENT ROOF 4,253 DETENTION DRIVEWAY 2,001 DETENTION ACTIVITY ZONE 210 PERMEABLE PAVERS PARKING AREA 908 DETENTION PARKING AREA 3,523 OFF -SITE DETENTION WEST WALKWAY 113 DETENTION WEST WALKWAY 384 OFF -SITE DETENTION NOTE: ROLLAWAY BINS WILL BE KEPT BY EACH UNIT. THERE IS NO COMMON DUMPSTER. Know what's below. Call before you dig. DIAL TOLL FREE AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER N O = Q N c0 (n D_ O 1 m N pD L L Z O O N W Q m o w z p W w m 0-, W U m < = Q o cf) o Q 0 a- m U) z O U) w W (n W Lc) U 1- 00 g00 CLCy) Ld NNV)� zl:2L0 w 0 N U O U) ww :2 W O CK (n Z o00a H-�� N o I o Z z O0)O w :2 N :2 x a_ 000 WOOW C° o � o I � � r� O v (DN >0' 00 co co +M0L N O cV cfl ++ CD��_� RESUB W ' z�w-p - Jun 24 2022 = Z . J N H O x Q CITY OF EDMONDS DEVELOPMENT SERVICES O O = Q � 00 m a- LL, W DEPARTMENT BLD2021-0356 � z W � APPROVED FOR CONSTRUCTION w CITY OF EDMONDS m z ENGINEERING DIVISION o z — DATE: APPROVED AS NOTED � Q (D �8/11/2022 a_ Q Z BY: w CITY ENGINEERING DIVISION EX 36D�ry 13+00 —I- - / I / I '�- r- SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. N W cn 0 O 1 m z oN O � w m w ~ I I Z 0 w o o 0 U o Q (� a_ I Q I I PANCAKE HAUS I m CONNECTION TO BE MAINTAINED AT ALL TIMES. CONFIRM CONNECTION o 0 0 os� o 0 0 0 0 o 0 I POINT AND PRESERVE. I w Q C5 SEWER CLEANOUT REQUIRED WITHIN 2-FT OF OUTSIDE OF BUILDING (TYP) W 10' SEWER EASEMENT SEE SHEET 9 FOR DRAINAGE FEATURES —CORE EX MANHOLE & INSTALL �+! NEW PIPE WITH KOR-N-SEAL. INSTALL INSIDE DROP PER COE STD DEf SS-220. n T I�yl b NVU 5UK.5,D I ' 1 In bi II @ 5.34% _ i : U O I Li I A 1g 00 - GI � 6 I �` 0-O) i WATE CLEANOUT PER 7ERS PE OE STD D 6 I , 7- /5- Q N )E STD ET S-200 ��p�`L\��,� / LLd 4-131 R3 ®2O \ �F+����11� 2 z 1 :2 LO I Q REMOVE EX METER. a I _, ABANDON W TER a a I '� w O� N LINE AT TH -. M < a ° a d a . °• ° a I I1—`_ITT--------- ° a I W W {`} :2W J_ R%�y 000� SEE SHEET 8 FOR RI MENTS �� �� ems, — N 14+00 ; ���F` O 60 p p I z z --— r— — �1''S-- � 000 238th STREET SW — � N 0CL wa0 Ld 0C) �w a I!SE) a o GRAPHIC SCALE 1 "= 10' N CD1-1 0 10 20 30 40 I �'��� 1 CD om E / O O 17 U o O O CL Know what's below. Call before you dig. DIAL TOLL FREE Q AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER � O C, + � rn N CD .-. I LC 00 00 w / � +00� N Q O NcD+ 00 �^ o 0 C RESUB zJ w� w w`'� = Z J a E w Jun 24 2022 (0 0 = _ j CITY OF EDMONDS DEVELOPMENT SERVICES m W L W / Q DEPARTMENT o BLD2021-0356 z w o� APPROVED FOR CONSTRUCTION w CITY OF EDMONDS m z J ENGINEERING DIVISION 0 z E DATE' APPROVED AS NOTED Q z �8/11/2022 w Q Z z 0 BY: Of w CL o a CITY ENGINEERING DIVISION o_j C� SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. W W K) p Lot, U N (n O Z J p�(n W Ld p 1 ~LLJWW W U g Y M �Ztj �jIZLU Q1 W� �m0 U'��`� 0 Ir) w STORM �m I-m N=(n +HLd ��LC) W' mof W �0 n= W SEE SHEET 6 Zo � _s w� r7Q0 a_0 UN CVN Ld !Y0 ogoiwm YOd C) o r` C) —V) W U)ww Y�oliUI zo LLI Ld r0 2zp LLJ00 p 0 W m Oo U w o w m LrJQ ����W WATER LLIN0 U a wW C 0 EE1SHEE_ 7 CILEX _ N r�zp N r�wM J 0 Ld 3 � �w� �m o / f •� I I SD ° I v n' ° 7 iAl EADT • v G ate---� . . • ° . • v A, v ° • jC� EX SIDEWALK a . ' :. ':. a°.�°... v o `n S\G� EX CURB & GUTTER .50 I A � NI II - ^ / / SS p� FPS � o< I '-& 429.89 FL -BRASS PLUG w/ PUNCH IN WELL / I REPLACE VISITED MAR 2017 I I SE16j �S1F,NC CURB & GUTTER CATCH BASIN r cc, jGHj , 00 / I / / I SD LINE PROFILE HEREO EX CURB & GUTTER EX SIDEWALK - — - - H II II PUD I I r-, POLEj I I I O Al PER I COL STD a� DET ITR-520 GRATE WITH SOLID COVER - — I CD - BI UE REFLECTOR P R COE STD DIET WA-100 I i� N I V) 12" DIP. REPAIR TRENCH PER COE STO DET GU-410. I EX EP o 0' EAD E _-- m \ In� I I I I II I I I I I I I I SEWER I C SEE SHEET 7 I 1 I Q / SD LINE C SEE SHEET 9 m U o� rn WWo m � �r Ld 0 0 ` Lj W W W W X W Z �m ciLd �IDZ� m co c+YWNom a_ ZOO O0 I mUD_ cn�co nOd jZlv� UW QW Q� c)I \ QLdZ (6 Ld U (nmwo > W�O WLJ o �Ism0I,IYL�Y CO W �M0 o �n�XN mo ��,(WWMiW W0) z OU) OULj X�Acn 0L + + —WI— 0 >z w� 7�w N W ri oo zI2woa 6mo +LLI � 0CL0 of 0UZ z \ Ld ° dd. a A'/ ° .. v :. d a ` ° A. O'HEAD T v' G v• I . T. A. AA_.. . \ a ° d II v v 14 8.94% \ I \ I - CURB & GUTTER- - PER COE STD I \ DET TR-520 - i 1 0 - —238th STREET SW r w/ PAINTED CENTERLINE. I SEE NOTE. TED MAR 2 17 EX EP I SD- \�-- — o m I REFER TO SEPARATE LANDSCAPE ROW RESTORATION LIMITS TO BE DETERMINED BY CITY I "2 w I PLAN FOR STREET TREES/PLANTING INSPECTOR. SEE NOTE. ' ANGLED TRENCH PATCH NOT ALLOWED. �LO Q r- � N U o I mince II m0 LO r) U ++ OroVQ IN 0 OV) o� O +10000 0 PO �c-4 EX GROUND @ PIPE =3.167, IN — 430 - 0 w w o q LINE A 40.10' - 12" DIP 10+00 —_S[�__---- 30, 7' 5' 1 4.5'f SIDEWALK STREET- N SCAPE 2 I 2% MIN2% MIN � EX PAVEMENT 04 SIDEWALK PER COE STD DET TR-531 PAVEMENT REPAIR PER DRIVEWAY PER COE COE STD DET GU-410 STD DET TR-54 CURB & BASE PER COE STD DET TR-520 TYPICAL ROADWAY SECT/ON 1" = 5' 0 - 0 v I I J ----- i l---I�--- CO C4 I �� I--- II---- I DO / om U _ / \ Lt7 LXLI SD LINE C SEE SHEET 9 � J O'HEAD T ... � .. — �� 15+ 00 ,M JG 12" CPEP. REPAIR SIGHT TRENCH PER COE 12 STD DIET GU-410. 1 ` - �+ HTA� SACK SS — sr� 1QZ'>>6'-- -- 15+00 GRAPHIC SCALE 1 "= 10' 0 10 20 30 40 NOTE: CENTERLINE WILL BE RE -STRIPED, AS REQUIRED, PRIOR TO PROJECT COMPLETION. NOTE: UTILITY PATCHES WITH LESS THAN 20-FEET OF SEPARATION SHALL BE COMBINED AND FULL WIDTH OR HALF WIDTH OVERLAY WILL BE REQUIRED DEPENDING ON THE EXTENT OF DISTURBANCE. WHERE UTILITY PATCHES FALL ENTIRELY WITHIN ONE TRAVEL LANE, THE OVERLAY SHALL EXTEND TO THE CENTERLINE OF ROADWAY. WHERE UTILITY PATCHES EXTEND INTO BOTH TRAVEL LANES THEN A FULL WIDTH OVERLAY IS REQUIRED. NOTE: A SEPARATE RIGHT-OF-WAY CONSTRUCTION PERMIT IS REQUIRED FOR ALL WORK WITHIN THE CITY RIGHT-OF-WAY. • Know what's below. Call before you dig. DIAL TOLL FREE Q 1 AT LEAST TWO DAYS BEFORE YOU DIG (800) 424-5555 UTILITIES UNDERGROUND LOCATION CENTER � o(0 C I m N a0 L L_ Z O 0 N 00 Q m w � z p W w Q of W _ o D_ U) o Q 07 C) Q m W V) WLO U r- g00 00 0-0) = N z Ld N C4 z1:2L0 Z Q Ln w C) OI��N M Q V) � 07 07 H w Iw �Lq 0 z= Q 00 00 N 07 07 o I o w z z 00)0 o :2 N :2 00C) � E i rn o 17 U o O o �C)�® N o .-. I w i ���Do � ��oLO a) Q O NcD4 O0 U) o 0 RESUB zJ wE w L;j I�=Z a E Jun 242022 ..J c000x� CITY OF EDMONDS 00 m m LLQw 2 DEVELOPMENT SERVICES Q DEPARTMENT BLD2021-0356 z o W o� APPROVED FOR CONSTRUCTION W CITY OF EDMONDS m z J ENGINEERING DIVISION o _ z DATE' APPROVED AS NOTED Q z �8/11/2022 w Q -zc 0 BY: Of Lu CL o a CITY ENGINEERING DIVISION o_j 7' 4' PROP GARAGE FF=424.70 - TYP DRIVEWAY PER DETAIL BELOW PROP GARAGE FF=424.70 SEE SHEET 1 FOR DEFERRED SUBMITTAL REQUIRED PRIOR TO WALL CONSTRUCTION 428.67 TW 2% MIN PROP DRIVEWAY HOUSEEX 2.2 GROUND 4 PIPE ANCHORING PER DETAIL Sdl� 60" SRPEP DETENTION TANK SECTION A -A 1" = 4' - _[EX GROUND 2.27% PROP DRIVEWAY MAX EX EX CAR PARKING CURB--,,,,, _GROUND LU PROP O w GROUN �z 2 �1% GRAVITY WALL SECTION C-C 1" = 4' EX EX CAR PARKING CURBGROUND SECTION D-D 1" = 4' 5.5' RE -LOCATED ADA PATH CONTROL STRUCTURE EXISTING PARKING I SECTION E-E 1" = 4' w z J 5.5' 6.40% o: OL _6�.40% MAXI CUTOFF TO FRO SETNT ACK . SECTION B-B 1" = 4' .1.5'. IS w a_ Ow 0, z: a_ J 0 nAA,, 'n SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. 1EX GRAVITY WALL 22.47 TW EX HOUSE CUTOFF WALL Ls' O FRONT ETBACK LINE FF=418.6 �C PERVIOUS CONCRETE PAVERS WEARING COURSE SLOPE PER GRAVITY ALL .78 TW !' SPECIAL INSPECTIONS REQUIRED FOR DETENTION Y PIPE ANCHORING -s.rssass.csa:::<s.rs, crs...rsass.csa:.s.r....rss.ic..r. LEVELING COURSE NO. 8 UNIFORMLY GRADED CRUSHED (ANGULAR) STONE, THOROUGHLY WASHED • • • •• RESERVOIR • • ALONGBOTTOM & SIDES PER PERMEABLE • WSDOT SECTION 9-33.21(l) EXISTING NON -COMPACTED SUBGRADE. -PERME4BLE PAVER DETAIL �5" CONCRETE .4 °d - I 8" CSTC r ..........:.......:.:... . ..:..:..:.....: SCARIFY 12" & RE -COMPACT TO 95% TYPICAL DRIVEWAY DETAIL 1 " = 31 2" 2„ 411 �I 1, � NOTES: 1. DRAIN IS SYMMETRICAL ABOUT �. 2. APPLY FLEXIBLE SEAL BETWEEN DRAIN & BUILDING. WALL DRAIN DETAIL 1" = 1' 1.75' DRIVEWAY PAVING PER FIDETAIL THIS SHEET d V d d a `o 60" SRPEP DETENTION TANK NOTE: 1. PROVIDE & INSTALL CONCRETE TO RESIST 800 LB OF UPLIFT PER FOOT OF TANK. DETENTION TANK ANCHORING 1" = 4' B 2 EXTRA #5 #5@8" 8 PLACES EA WY 3" CLR TYP 2-#4�__) 4 PLACES i 3'-8"0 OPEN 2'-9' PLAN B SQUARE ADJ. GRADE AROUND FRAME _ OR LEAN SLURRY SCARIFY 6" 2'-9" 1 ' & COMPACT SECTION B-B TO 95% 5'-6" NOTES: 1. DESIGN IN ACCORDANCE WITH AASHTO, 17th EDITION AND ACI 350. 2. DESIGN LOAD HS25. 3. EARTH COVER=1 ' MAX. 4. CONCRETE STRENGTH=4,000 psi 5. REINFORCING STEEL=ASTM A615, GRADE 60. 6. PROVIDE ADDITIONAL REINFORCING AROUND OPENINGS EQUAL TO THE BARS INTERRUPTED, HALF EACH SIDE. ADDITIONAL BARS TO BE IN THE SAME PLANE. 7. TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND BARS A MINIMUM OF 12" BEYOND OPENING, BEND BARS AS REQUIRED TO MAINTAIN BAR COVER. 8. PROTECTION SLAB AND ALL MATERIALS TO BE PROVIDED AND INSTALLED BY CONTRACTOR. 9. DETAIL DESIGN BY DELTA ENGINEERS, ARCHITECTS AND LAND SURVEYORS, ENDWELL, NY. DETENTION TANK ACCESS DETAIL 1" = 3' 0 1' 0 0° PROP DRIVEWAY d a < ji NATIVE BACKFILL COMPACTED TO 85% IN z x TREE ROOT PROTECTION Q ZONE & 95% ELSEWHERE. SELECT .;:::::T TV. BACKFILL 6" SEWER _ z 1'MIN 4" H.C. CLR -� 2' 4' 2' MIN TYPICAL UTILITY TRENCH 1" = 2' N N O c0 = (n Q D_ O I m 12" DRAIN " 00 w PIPE -� z 0 N 0 \ 8" Ox 18" STUB, Ld O \ \ ( FACTORY) m o 54" w ~ w A MANHOLE A � w Q � m � Q � o w \ 0 c� O� Q1 (n 0 I Q 60" STEEL 8" DRAIN REINFORCED m PIPE PE PIPE STEPS OR LADDER CONSISTENT PLAN WITH COE STD DET SD-501 GU-423 I I SURFACE cn 424.55 PER PLAN 0 cn w Qf 4 Y " 2 8" STEEL RISER, OUTLET & SHEAR GATE. 60" STEEL 16" MAX I REINFORCED PE PIPE LINE C o S=1.00% ' ' I 'L VEL 417.06 IE o 417.06 IE J Z J I Q 415.06 C/) 1%2"0 ORIFICE C/) z � I N & o 41 � .06 U I SECTION A -A NOTES: 1. FLOW CONTROL STRUCTURE SHALL BE CONSISTENT WITH COE STD DET Q SD-301 . SHEET 14 2. Q CONTROL STRUCTURE DETAIL 1" = 3' w Cf) ILL]`n U r__ 00 g00 wCr) Ld Ln I °� �v -ro z I : m I \ � o� w :2 Or":N L EX CB & \ �� ; Of C/) 12" PIPE TO Z BE REMOVED \ \ ' \ \\ \ EX CONTROL EX 36" CMP 427.50 IE \ \\STRUCTURE TO DETENTION TANK \ BE MOVED (n [___ D� I 12" STUB SET ww :2 Ld RADIALLY @5% _ � 428.61 IE Z = 1 o 0 J I ~ro CLEAN PIPE UNDER mI N Uj DRIVEWAY & INSPECT m I o I o I 7•9>> REFER TO CITY w O rn 0 m �J I I STANDARD DETAIL o 0 0 0 a ml I SD-301 - FLOW D_ w 00 w SITE tA I I CONTROL STRUCTURE R-O-W „ 001 NEW 36 CSP, I W ST STA 13+66.08, 33.62' LT 54" CB TYPE 2 �3d S�� Ire GALVANISED ASPHALT NI ° I I a I I v `v 427.50 IE 36" NW o$1 �� o ` LINED & COATED col 427.47 IE 12 S `� ; �l l CID 431.47 TOP OF EX RISER 3 o � F w� co 432.64 TOP OF SLAB 0� SEE ALSO SECTION E-E THIS SHEET NOTES TO CONTRACTOR E 1) FULLY EXPOSE THE OUTSIDE OF THE EX CONTROL STRUCTURE MH PRIOR TO ORDERING V-) o NEW 36-INCH PIPE TO VERIFY CONNECTION. o 2) FULLY DIMENSION INTERIOR OF EX CONTROL STRUCTURE MH PRIOR TO AN REMOVALS. MATCH NEW ELEVATIONS TO OLD ELEVATIONS 0 0" 3) METAL COUPLING BAND REQUIRED FOR CONNECTION OF NEW PIPE TO OLD PIPE U) o a' C-4 4) CSP TO HAVE PREFABRICATED 12" STUB. Do o Do MODIFICATION OF EXISTING DETENTION TANK �� U) "`° 1" = 4' _ N w z _j RESUB LdJ z _ NHOj�Q coo=Q:� Know what's below. Jun 242022 00mmlj_w • Call before you dig. CITY OF EDMONDS gLD2021-0356 DEVELOPMENT DEPARTMENT CI) z W DIAL TOLL FREE APPROVED FOR CONSTRUCTION ( W AT LEAST TWO DAYS CITY OF EDMONDS m - O BEFORE YOU DIG ENGINEERING DIVISION o z z - (800) 424-5555 DATE: APPROVED AS NOTED �ai11i2o22 Q w UTILITIES UNDERGROUND LOCATION CENTER BY; CITY ENGINEERING DIVISION N L.L 0 IL O ,A:- 0 N J � E -6 a a, z� �a �o 3 m a a o_j 20 -0-0 31 RISER B1 60"0 REINFORCED BULKHEAD Al W/ 6"0 STUB A2 I I lil A B D O C 80'-0" RISER INFORMATION PIECE RIM ELEV. SYSTEM INVERT 36"0 RISER 61 424.31 417.06 36"0 RISER D1 424.31 417,06 20'-0" _ 36"0 RISER D1 15PS BELL & SPIGOT CONNECTION SEE DETAIL SHEET C2 THE UNDERSIGNED HEREBY APPROVES THE ATTACHED (4) PAGES INCLUDING THE FOLLOWING: • PIPE STORAGE = 1,524 CF • WALL TYPE = SOLID • DIAMETER = 60" • PIPE MATERIAL = DUROMAXX • JOINT TYPE = 15PS BELL & SPIGOT CUSTOMER DATE ASSEMBLY SCALE: 1" = 5' PIPE STORAGE: 1,524 CIF LOADING: H20/11­125 PIPE INV. = 417.06'± NOTES SE 1 /4• SEC. 31 • T. 27 N. • R. 4 E. • W.M. STUB INFORMATION PIECE STUBINVERT SYSTEM INVERT 6"0 STUB A2 417.22 417.06 8"0 STUB C2 417.22 417.06 60"0 REINFORCED BULKHEAD C1 W/ 8"0 STUB C2 • ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. • ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER OF RECORD PRIOR TO RELEASING FOR FABRICATION. • ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM D3350. • ALL RISERS AND STUBS ARE HIGH DENSITY POLYETHYLENE UNLESS OTHERWISE NOTED. • RISERS TO BE FIELD TRIMMED TO GRADE. • ANTI -FLOTATION PROVISIONS DUE TO HIGH GROUNDWATER OR OTHER FLOTATION CONCERNS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER ON RECORD. • ALL FITTINGS TO BE TESTED FOR WATERTIGHT WELDS. y ne pm,en owner. e,gineer anC mniracmr by °'a°E '° '°s°'°°p,Ecr'°°n.° Np,m°rm„ \I/� 600" DUROMAXX DETENTION SYSTEM 696082-010 PHOJECI No 696082 SEU. N. 0,o VS/,7/22 w s °.wnYpeam reM maybo° ea �Pma� an. moo�roamany mannm w,moal mo pfror w.moncwsem of C .. NTECH• DurMaxx• - DESIGNED. DRAWN `° `P-11 `�,Ii 1PeA'^"' `° o9k.o° Com°c^eawls I., t,1 adY It M,1-1pons,b 111 for ENGINEERED SOLUTIONS LLC A REINFORCED STORM DRAIN PIPE EDMONDS TOWN HOMES SKJ SKJ it metro amiec belweun ere su ivtl .n a on Pw www.ContechES.com CONTECH EDMONDS WA CHECKED- APPROVED: mee.w���, besea ana anl,al nemconainpns a.e noun - 11-1 wp proq.„e,. me a aI repanc.a ma„ be as 9025 Centre Pointe Dr.. Suite 400, West Chester, OH 45069 PROPOSAL ' SKJ SKJ bC. a mmee�e"rmrte a, a, °Ilaeee,9n Dn, ^ C SITE DESIGNATION: DMAXX SHEET NO. aoP.PIFn°„ao„nYr«cP:,answ�e,„,m,,,,,,�_,nwmr,�.,,.°, 800-338-1122 513-645-7000 513-645-7993FAX DRAWING r P1 4 Iwccu.ale mlwmenpn,p gab mneR MARK DATE REVISION DESCRIPTION BY TRAFFIC RATED FRAME & GRATE OR METAL PLATE & FRAME SHALL BE SEPARATE FROM RISER TO PREVENT ANY LIVE LOADS BEING DIRECTED ONTO RISER REINFORCED CONCRETE COLLAR BY OTHERS TO PREVENT LIVE LOADS FROM BEING IMPOSED ON RISER TYPICAL BACKFILL HDPE RISER PIPE \ AS SHOWN ON BACKFILL DETAIL DUROMAXX PIPE FINISHED GRADE NOTES: 1) RECOMMENDED 30" DIAMETER MIN. RISER. GASKET MATERIAL SUFFICIENT TO PREVENT SLAB FROM BEARING ON RISER TO BE PROVIDED BY CONTRACTOR RISER BACKFILL ENVELOPE SHALL BE CLASS 1 MATERIAL PER ASTM D2321 UNDISTURBED EARTH TYPICAL MAINLINE PIPE BACKFILL PER PROJECT SPECIFICATIONS UP TO PIPE EMBEDMENT ZONE. TYPICAL PIPE BEDDING STANDARD RISER INSTALLATION DETAIL SCALE: N.T.S MAX RISER 0 THAT DOES NOT REQUIRE CONCRETE REINFORCEMENT FOR COVER HEIGHTS OF <10' MAINLINE DIAMETER RISER (MAX 0) 42" 42" 48" TO 120" 36" FOR MORE DETAILED INFORMATION CONSULT FITTING STUB REINFORCEMENT TABLE ON DETAIL #3UU IF REINFORCEMENT IS REQUIRED, USE RISER DETAIL #400. ACCESS CAP FINISHED GRADE BY OTHERS TII•tl1y, aft~-. C"i go�e�•�Coat�diP) ■•vex • \I/� C%.►,NTE H ® Dur Maxx " 60Q� DUROMAXX DETENTION SYSTEM - 696082-010 PROJECT No 696082 SEO. Na 010 DATE. 5/17/22 DESIGNED DRAWN. A REINFORCED STORM DRAIN PIPE Q.1i f•Y•!••MYRr.[rel�1•e•INM epa EDMONDS TOWN HOMES SKJ SKJ CfAO,«o.e•rAl••..ryballFerRrolp,�Y• w avi M ENGINEERED SOLUTIONS LLC CHECKED SKJ APPROVED'. SKJ R�.Id..+[t�l •e .,M.E ,1/MwMM, upon wn;cn www.ContechES.com 9025 Centre Pointe Dr.. Suite 400. West Chester, OH 45069 CONTECH PROPOSAL EDMONDS, WA SITE DESIGNATION' DMAXX ae �•e��.srer ml�.. ere ermunocea mew.al•o�FaE.EEINfrwa nipwiiib.f pplma rsaw.w�.r�+�w•^ SHEETNO. ae��leltr�prveedl•esOwNa�ll�mm�lora°, 800-338-1122 513-645-7000 513-645-7993FAX DRAWING P3 of 4 MARK DATE REVISION DESCRIPTION BY 1 6a 0 z z w 0 m 2 w d PIPE ZONE 1 a If HAUNCH ZONE I BEDDING TRENCH CONDITION FINAL BACKFILL INITIAL BACKFILL D12 `yf 4 s DIAMETER EMBANKMENT CONDITION IN MAX 75% MAX DIAMETER C❑VER)K C❑VER)K)K 30'-42' 50'-0' 37'-6' 48'-96' 30'-0' 22' 66' 'FOR INITIAL BACKFILL USE ASTM D2321, FOUNDATION <°�'[�m �^ CLASS I. II MATERIAL. 2 \ "REDUCED MAX. COVER WHEN USING ASTM w� D2321 CLASS It MATERIAL IN TRENCH/HAUNCH ZONE OR FOR FIRST INITIAL FILL ENVELOPE 1 to BACKFILL. OMINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER PIPE. MIN. WIDTH = (1,25 x DIAMETER) + 12" (FOLLOW ASTM D2321) 1a MINIMUM EMBANKMENT WIDTH IS 3 PIPE DIAMETERS BUT NO LESS THAN 2' OUTSIDE OF SPRINGLINE. OFOUNDATION SHALL BE WELL CONSOLIDATED & STABLE. OBEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE BOTTOM OF THE PIPE, 4" TO 6" IN DEPTH. ODUROMAXX STEEL REINFORCED (SRPE) PIPE. OHAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION. 5a INITIAL BACKFILL FOR PIPE EMBEDMENT MATERIAL TO MEET ASTM D2321 CLASS I, II, III OR APPROVED EQUAL, COMPACTED TO 90% STANDARD PROCTOR (NATIVE MATERIAL CAN BE UTILIZED THAT MEETS ASTM D2321 OR APPROVED EQUAL). • ALL LIFTS PLACED IN CONTROLLED MANNER. TO PREVENT UNEVEN LOADING, IT IS RECOMMENDED THAT LIFTS NOT EXCEED 8" UNCOMPACTED LIFT HEIGHTS. OINITIAL BACKFILL ABOVE PIPE MAY INCLUDE ROAD BASE MATERIAL AND RIGID PAVEMENT (IF APPLICABLE), MINIMUM COVER STILL APPLIES, OTHERWISE: 6" MINIMUM FOR PIPE DIAMETERS 30" - 60" 12" MINIMUM FOR PIPE DIAMETERS 66" - 96" 6a HEIGHT OF COMPACTED COVER PER DIAMETER FOR CONVENTIONAL HIGHWAY LOADS (DISTANCE MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT): 12" MINIMUM FOR PIPE DIAMETERS 30" - 60" 18" MINIMUM FOR PIPE DIAMETER 66" - 72" 24" MINIMUM FOR PIPE DIAMETERS 84" - 96" OFINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS PER THE PROJECT PLANS, SPECIFICATIONS. ENGINEER OF RECORD. NOTES: • GEOTEXTILE SHALL BE USED AS REQUIRED TO PREVENT SOIL MIGRATION. • FOR MULTIPLE BARREL INSTALLATION THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE RUNS SHALL BE = PIPE DIA./2 OR T FOR PIPE DIAMETERS 72" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING. • BACKFILL REQUIREMENTS SHALL FOLLOW ASTM D2321. IN THE EVENT OF DISCREPANCIES, ASTM D2321 SHALL SUPERCEDE THIS DETAIL. TYPICAL BACKFILL DETAIL SCALE: N.T.S u ro IM pmlect owner, agineer arM conVaclor by Canle"c� ER9Iw°fpa 5m Won, EEC I"Conletm, Nplmer m„ �_\ /� N T E H• Crew„g. nor anY Me mertM, meY be u,ea. nP.CuceC a D LII r rM a X moai4ee In any manner w,moul P. pn. wr,lion conspm �,., comet^ Famremcomrly ,. �oremmeux., awn rsY ar,e Comecn o.pr°,vv alsua,ms any eaeiery or sponsba,ry ror ENGINEERED SOLUTIONS LLC A RElnroeeeD STORM DRAIN F www.ContechES.com n a.s,re ,roe. baN.ea� v,e su .a ,mo,maw° „ ° wn,u, me d-,, .,oases ana -.1nem conalppns are encoun.rea CONTECH PIN-- th.ae alacf°Pan°., ... e°,epp,w° 9025 Centre Pointe Dr .Suite 400. West Chester. OH 45069 PROPOSAL ro Cpn,ecb immeaialely mr rmesalwYnn m me eeslgn Con@<n a¢epl, no ."1 do for do,�yns baspe °n °„���ny. m,.,,nw°. °� 800-338-1122 513-645-7000 513-645-7993 FAX DRAWING ,.curate mmrme,ron ,u ,cab mbeR MARK DATE REVISION DESCRIPTION BY DUROM� GASKFT BELL DETAIL 2 tY �Uj UJ ¢< �o �w Z O w- J rn I- mo BELL LENGTH DUROMAXX BELL & SPIGOT GASKET i f: HDPE SPIGOT STEEL REINFORCED SPIGOT SPIGOT DETAIL NOMINAL PIPE DIA. (in) BELL O.D. (In) BELL LENGTH (in) -MAX 30 34.0 890 36 39.9 890 42 45.8 8.90 48 52.3 8.90 54 58.2 890 60 64.1 8.90 72 77.6 11,15 HIGH PERFORMANCE (HP) JOINT DETAIL TYPICAL PIPE CONNECTION DETAILS SCALE: N.T.S. 600" DUROMAXX DETENTION SYSTEM - 696082-010 EDMONDS TOWN HOMES EDMONDS, WA SITE DESIGNATION: DMAXX NOTES: 1. ALL ELEVATIONS, DIMENSIONS AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER PRIOR TO RELEASING FOR FABRICATION. 2. THIS PROJECT IS FOR 060" [1524 mm] DUROMAXX. 3. CONSIDERATIONS FOR CONSTRUCTION EQUIPMENT LOADS MUST BE TAKEN INTO ACCOUNT. SEE DETAIL ON THIS PAGE 4. ALL PIPE DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES. 5. SYSTEM IS DESIGNED FOR H2O AND H25 LOADING. SCOPE THIS SPECIFICATION DESCRIBES DUROMAXX PIPE FOR USE IN MULTIPLE APPLICATIONS IN 30" [750 mm] THROUGH 120" (3000 mm] NOMINAL DIAMETERS. DESCRIPTION DUROMAXX IS A REINFORCED POLYETHYLENE PIPE WITH A SMOOTH WATERWAY WALL AND EXTERIOR PROFILE THAT IS REINFORCED WITH HIGH STRENGTH GALVANIZED STEEL RIBS. THE CONTINUOUS REINFORCING RIBS ARE COMPLETELY ENCASED WITHIN THE POLYETHYLENE PROFILE. DUROMAXX IS MANUFACTURED USING A HELICAL WINDING PROCESS THAT RESULTS IN A CONTINUOUSLY FUSION WELDED CIRCUMFERENTIAL LAP SEAM. THE PIPE PROFILE IS MANUFACTURED USING A HIGH QUALITY PRESSURE -RATED THERMOPLASTIC MEETING THE REQUIREMENTS OF ASTM F2562 "STANDARD SPECIFICATION FOR STEEL REINFORCED THERMOPLASTIC RIBBED PIPE AND FITTINGS FOR NON -PRESSURE DRAINAGE AND SEWERAGE". FOR THE PURPOSE OF HYDRAULIC DESIGN, THE RECOMMENDED MANNING'S "N" VALUE SHALL BE 0.012 FOR PIPE DIAMETERS INCLUDED WITHIN THIS SPECIFICATION. PIPE LENGTH & ALL DIMENSIONS SHOWN ARE SUBJECT TO MANUFACTURERS TOLERANCES OF ±1 % ACCORDING TO ASTM F2562. MATERIAL PROPERTIES VIRGIN HIGH DENSITY POLYETHYLENE PRESSURE -RATED RESINS ARE USED TO MANUFACTURE DUROMAXX PIPE. RESINS SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF CELL CLASSIFICATION 345464 C AS DEFINED AND DESCRIBED IN THE LATEST VERSION OF ASTM D3350 "STANDARD SPECIFICATION FOR POLYETHYLENE PLASTICS PIPE AND FITTINGS MATERIALS". FITTINGS ALL FITTINGS SHALL BE FABRICATED FROM DUROMAXX PIPE. ANY FITTINGS 030" [762 mm) AND BELOW WILL BE HDPE PIPE ALL FABRICATION OF THE PRODUCT SHALL OCCUR WITHIN THE UNITED STATES. INSTALLATION INSTALLATION SHALL BE IN ACCORDANCE WITH ASTM D2321 "PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY -FLOW APPLICATIONS" ALONG WITH PRODUCT -SPECIFIC RECOMMENDATIONS CONTAINED IN CONTECH INSTALLATION GUIDELINES FOR DUROMAXX PIPE. INSTALLATION SPECIFICATION PRE -CONSTRUCTION MEETING PRIOR TO INSTALLATION OF THE DRAINAGE SYSTEM A PRE -CONSTRUCTION MEETING SHALL BE CONDUCTED. THOSE REQUIRED TO ATTEND ARE THE SUPPLIER OF THE DRAINAGE SYSTEM, THE GENERAL CONTRACTOR, SUB CONTRACTORS AND THE ENGINEER. INSTALLATION OF PIPE IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR PROJECT ENGINEER TO ENSURE THAT ALL QUESTIONS ABOUT INSTALLATION ARE ADDRESSED PRIOR TO APPROVAL OF SYSTEM. ALL DETAILS FOR INSTALLATION ARE LOCATED IN THIS DRAWING PACKAGE ANY QUESTIONS CONCERNING THESE STANDARD DETAILS CAN BE ADDRESSED BY YOUR CONTECH REPRESENTATIVE PRIOR TO APPROVAL. BACKFILL SHALL BE PLACED TO THE PROPER ELEVATION OVER THE SYSTEM AS OUTLINED IN THE PLANS. MINIMUM COVER FOR CONSTRUCTION LOADING NEEDS TO BE DETERMINED BASED ON THE TYPE OF EQUIPMENT THAT IS PLANNED FOR CONSTRUCTION. PROPER COVER FOR CONSTRUCTION EQUIPMENT IS DETAILED IN THE CONSTRUCTION LOADING DIAGRAM. PROJECI No SEU. Na L-. _ 6960 82 010 5/17l2t DESIGNED DRAWN. SKJ SKJ CHECKED APPROVED SKJ SKJ SHEET NO.'. P2 OF 4 a.rrsea•petraa.rc ell�.evattr mlm«w o„r •� �re�r•uctowlr> Nr.e•\I/� • %���N Dur�Maxx® 60Q� DUROMAXX DETENTION SYSTEM - 696082-010 696082 010 5/17/22 n��ir.rsf�i.rp��'�e'a DESIGNED DRAWN. ca.•s. raMlft-W�a.rr lsFr v.IrlteM A REINFORCED STORM DRAIN PIPE SKJ SKJ ca�alao.rr•rr.•w�rowvwwsr•Irw Fpe u.. ENGINEERED SOLUTIONS LLC II Csuu nc .0 IM°,ma4pn a wFla, °re www.ContechES.com CONTECH EDMONDS, WA CHECKED SKJ APPROVED SKJ mesraww 9�soas<aa�aaemalnelepprw�a°neareencwnmree s ,W wp,k prog.ssoi, mese Olscfepancres moil be ropoaea 9025 Centre Pointe Dr.. Suite 400. West Chester. OH 45069 PROPOSAL ro epmecn �mme°�a,ery ror ra-e+a,ualan of me oesgn Cpnlecb DRAWING SITE DESIGNATION' DMAXX SHEET NO .ten°.°' MARK DATE REVISION By 800-338-1122 513-645-7000 513-645-7993FAX P4 °F 4 corms mrormanon ,u I,oe a olners DESCRIPTION N O = Q N tD (n a- O 1 m T1_ N o0 LI_ Z O 0 N LIJ Q m o w z 0 LIJ w LLJ U m a- = Q 0 In Q (n 0 D- a m C/) Z O (n W CY TnT IN LLJ � CDC) CD g00 00 CL Cy) _ Z = 3 N LIJ H =�=1 N N V z l :2 Ln :D Q L0 w 0 N In LIJ LIJ W 0 CK _ In Z p 00 N CO o I o z z w 000 � :2 N'5 x 000 IZ LIJ 00 LIJ is 01 a� c E Cr) O Ni U o O O I � � O N 00 0-) �a'Otn tv O N CO+ 00 <-\ LLI Z J L LLJ 2 Z J 0 N H- Q (fl0=Q� 00 m D- L� W CI) BLD2021-0356 z R E S U B APPROVED FOR CONSTRUCTION W110� �� w Jun 24 2022 CITY OF EDMONDS m Uj z CITY OF EDMONDS DEVELOPMENT SERVICES ENGINEERING DIVISION DATE: APPROVED AS NOTED W Q z - CD DEPARTMENT ,�/ e-78/11/2022 a_ Q Z �iTie BY: Lu CITY ENGINEERING DIVISION <� N ID C)C) rn %-a W < E a W rn� N N rp 2 / I ,2 E N CD O "zf:. O N (n J E -6 O N Z N rn 0- 0 3 +� a O j o� SE 1 4, SEC. 31, T. 27 N., R. 4 E*, W.M. N (D U) a 0 1 m N o0 LL 2" x 2" WOOD/STEEL Z 0 O N N CONTOUR LINE Ld (TYP) Q FILTER FABRIC SECURED _ FILTER 2" x 2" 14 GA \��ly ANGLE TERMINAL m o w WIRE FABRIC EQUAL `� END UPHILL 24" TO 48" w w D- W 2 JP TO PREVENT FLOW Q m D_ _ 4 25' MIN RADIUS O _ Q O o D_ �Py G�� AROUND WATTLE (TYP) 2"x2"x24" UN TREATED o cn o Q (n 0 9-1j pO WOODEN STAKE (TYP) ; 0 QUARRY SPALLS O ��p 9 ^ Q WATTLE a- /_2-4" MIN DIA O O \� e' �`L �� Q1 ;: TRENCH, SEE NOTE 2 3" MIN Q 4 Q 12" MIN DEPTH O o- O 4" MAX _ m x: r r GRATE STAGGER P\� G. / " iv OVERLAPS �Q ^ G5MAX O 2"x2"x24" UN -TREATED ci WOODEN STAKE (TYP) NATIVE BACKFILL MATERIAL I 8" SFFl 15' MIN x>'' I 9e d FILTER SOCK WITH ,.,;.: 8" DIAMETER 1 CFJ PROVIDE FULL WIDTH �. OVER FLOW HOLES MIN OF INGRESS/EGRESS �' / Y"` ` PLAN VIEW FILTER SOCK WITH J (TYP) WATTLE DETAIL 4 OVER FLOW HOLES (TYP) AREA AVAILABLE FOR SPACING VARIES SEDIMENT TRAPPING SEE WATTLE SPACING FILTER FABRIC MATERIAL IN CONTINOUS ROLLS DETAIL NOTES: 6 e . CATCH BASIN (TYP) TABLE (TYP) 8" DIAMETER WATTLE p USE STAPLES OR WIRE RINGS TO ATTACH SPACING TABLE to FABRIC TO WIRE 1O THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE ? AND/OR INTO THE PUBLIC RIGHT-OF-WAY. �e, \�j� SLOPE MAXIMUM SPACING I j 2" x 2" WOOD/STEEL POSTS •'d\�\\\�,?T `' \ WATTLE (TYP) ck� 2O ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH.\\�\ \ SEE DETAIL 1 H:1 V 10'-0" A.: �j•�j//\ ' ' WIRE MESH FENCE NOTES: ,\\\/ /\/\\ \ :.� ...; o 1 TO SUPPORT FILTER FABRIC 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED \\/�\//�\/�\ ..'• 3H:1V 30'-0" iv ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 4H:1 V 40'-0" 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING SECTION A -A \\/ OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH WATTLE INSTALLATION ON SLOPES >4H:1V ONE RUN ONLY ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. Ld BURY BOTTOM OF FILTER 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL NOTES: Q `4 MATERIAL 8" TO 12" BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING NOTES: DEVICE. 6' MAX `CATCH BASIN 1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING 2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS. Z PROJECT MIN LENGTH OF (FEET) PROVIDE ATB OR ASPHALT CONSTRUCTION PERIOD. INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10). * NOTES: SIZE QUARRY SPALLS* TRANSITION WHERE FRONTAGE 2. ANY SEDIMENT IN CATCH BASIN INSERT 3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT ROAD IS AN ARTERIAL. SHALL BE REMOVED WHEN INSERT IS < 1/4 ACRE 30 UNDERCUTTING. 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER LENGTH TO BE DETERMINED ONE-THIRD FULL. EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON < 1 ACRE 50 BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON 3. CITY INSPECTION REQUIRED ON ALL 4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE ALL EROSION CONTROL METHODS < 3 ACRE 100 ALL EROSION CONTROL METHODS EROSION CONTROL METHODS BEFORE SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND O 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION BEFORE OTHER WORK CAN BEGIN > 3 ACRE 100 BEFORE OTHER WORK CAN BEGIN OTHER WORK CAN BEGIN. SURFACE. O Q ACTIVITY. REVISION DATE REVISION DATE REVISION DATE Lo REVISION DATE � STABILIZED CONSTRUCTION JANUARY 2018 � TEMPORARY JANUARY 2018 � JANUARY 2018 4 FILTER FABRIC FENCE JANUARY 2018 CITY OF EDMONDS FILTRATION SYSTEMS CITY OF EDMONDS ENTRANCE CITY OF EDMONDS SEDIMENT TRAP CITY OF EDMONDS WATTLE INSTALLATION W 0 PUBLIC WORKS STANDARD PUBLIC WORKS FOR CATCH BASINS STANDARD T PUBLIC WORKS STANDARD PUBLIC WORKS STANDARD DEPARTMENT DEPARTMENT DEPARTMENT Q DEPARTMENT DETAIL DETAIL DETAIL DETAIL O s t g APPROVED BY: R. ENGLISH E R - 9 00 APPROVED BY: R. ENGLISH E R - 9 01 ; t g APPROVED BY: R. ENGLISH E R - 9 0 2 t 1g9� APPROVED BY: R. ENGLISH E R - 9 0 3 Q V co W cn W Lo U � g00 00 CL = Q N PIPE ALLOWANCES FINAL JOINT SHALL BE A NEAT STRAIGHT HMA CLASS 1/2" Z RING AND COVER PER COE STD DTL W LINE. ALL EXPOSED VERTICAL EDGES SHALL PG 58H-22 MAXIMUM BE TACKED NEATLY PER WSDOT STANDARD (SEE NOTES 4 & 5) GU-420 PIPE MATERIAL INSIDE DIAMETER N N = 1' I SPECIFICATIONS 5-04.3(5)A APPROVED TACK FOR CURB AND SPLASH LINE ONLY: OR APPROVED EQUAL AND SEALED PER FRAME AND GRATE PER COE STD 1' REINFORCED OR 12" Z I :2 Ln DTL SD-320 SERIES PLAIN CONCRETE ��\� �:;=;;"; �: , ; ;j : -,� r,: •: �y. .: WSDOT STD 5-04.3(5)C. SLOPE EXCAVATION Q y/\/_ :,;�:�_�.:::• ; •;'�.:'r' 'a t.;_ \\ SEE COE STD DTL GU-410 TO AVOID UNDERMINING EXISTING PAVEMENT. i\�\ :"':. ':.....:.:::..:``:: -. •.:>..y::.�;� <';= 8.. MIN - ALL METAL PIPE 15" w C)I CL0\J \\//\ .:::.i : •': �::.::::::: `.'\ 18" MAX J I r� Q zzzzHANDHOLDS (2) SEE APPLICABLE STANDARD DETAILS O I . - GU-423 FRAME AND GRATE CPSSP* 12" SEECOESTa •° 20"x24" OR (WSDOT STD SPEC 9-05.20) rn // // / // // / // //,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ti •'� 24" CIA 0 z / / / / / EXISTING 6" MAX SOLID WALL PVC 15" r- wo / / / / / / / / HMA x.. ° _ (WSDOT STD SPEC 9-05.12.(1)) �w // // / // // / // // M1".4 '.•...................................................................... 12" (TYP) o ;. ' A. 0 / // / / // / / / 9 PROFILE WALL PVC 15" a / / / / / / / / a STEPS OR LADDER ^ S+ 30, (WSDOT STD SPEC 9-05.12(2)) o x / / / / :. :...: 48", 54", 60", 72" OR 96" h W W M a / / / / / / i vd / ORIENT SO THAT THEY 5 ^ 2 O / / / / / / / d �� ARE NOT ABOVE PIPE 0 * CORRUGATED POLYETHYLENE W 0� /// //// // EXISTING a a d a •, a ^ 2 S� STORM SEWER PIPE BEDDING MATERIAL (5/8" MINUS) d d SAND COLLAR OR 5 I (n 6" MIN // // // // // // // / CRUSHED PER COE MOD 9-03.16.A.2 MATERIAL \\ \\ a d a a ••\\ \\ \� II POLYPROPYLENE KOR-N-SEAL AROUND \' Z OR SUITABLE EXCAVATED MATERIAL AS �/, �/, �/ a JA* /, �// �SAFETY STEP PIPE 2 4", 6 OR 12" APPROVED 2 CITY ENGINEER IMPORT OR NATIVE MATERIAL 12" O.C. (TYP) I 0 00 Q Z // / / // / (SEE NOTE 2 BELOW) CRUSHED SURFACE BASE BACKFILL SHALL BE COMPACTED w I I (SEE NOTE 6) I � p O / / / / COURSE PER WSDOT STD TO 95% MAXIMUM DENSITY = I I NOTES: N w // // / // // SPEC 9-03.9(3) (SEE NOTE 2) a (n o / / / / (SEE NOTE 3) RISER SECTION 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE C)I C) IL / / / / TRENCH WIDTH 2.-0" WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). Z Z o OCnO MIN 2. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED WIRE 7) PRECAST BASE AND � N � MAX INTEGRAL RISER �r1 4� FABRIC HAVING A MIN. AREA OF 0.12 SQUARE INCHES PER 0' p O p 6" MIN // / // // // / FOUNDATION (IF REQUIRED) 1w_4" O SEE NOTE 4 ! \ MFOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY D_ W 00 W •� • . TO ASTM A497 (AASHTO M 221). WIRE FABRIC SHALL NOT BE PLACED IN KNOCKOUTS. 8" MIN 8" MIN -r NOTES: 26 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF 01 1. SEE CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF THE CURRENT WSDOT STANDARD SPECIFICATIONS FOR ALL JOINTS, RINGS, RISERS AND FRAMES. �3� c\1 3 SEE NOTE 1 BACKFILLING REQUIREMENTS. NOTES: 4. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX v�0 �� C-)�I 2. SUBMIT PROCTOR AND DENSITY TESTS FROM CERTIFIED TESTING COMPANIES DOCUMENTING THAT THE BACKFILL DIAMETER OF 20". KNOCKOUTS MAY BE EITHER ROUND OR 4 MEETS A MINIMUM OF 95% DENSITY PER ASTM D 1557. "D" SHAPE. a 4 C N 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). o 3. CSBC DEPTH SHALL BE A MINIMUM 6" OR MATCH EXISTING WHICHEVER IS GREATER. WHEN MATCHING EXISTING a 5. THE MAX DEPTH FROM THE FINISHED GRADE TO THE % 4w� O2 oN CSBC DEPTH GREATER THEN 6", THEN CSBC SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN PIPE INVERT IS 5-0 f ��d�s NOTES: EXCEEDING 6". CLEARANCE. 6. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL 1. MAXIMUM WIDTH OF TRENCH AT TOP OF PIPE 4. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH AND RISER SECTION SHALL NOT EXCEED 1/2"/FT. o GREATER THAN 4" SHALL MATCH EXISTING. PRECAST CONCRETE SHALL BE CLASS 4000. • 36" FOR PIPE UP TO AND INCLUDING 12" DIAMETER CD • O.D. PLUS 18" FOR PIPE LARGER THAN 12" NOMINAL DIAMETER 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX 7. CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE 5. ALLEY HMA DEPTH SHALL BE A MINIMUM OF 2" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER WITH STANDARD SPECIFICATIONS. MATING SURFACES SHALL 2. REFER TO CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF WSDOT STANDARD SPECIFICATIONS FOR MATERIAL HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42' FOR 54" CB, 48" FOR 60" CB, 60' FOR 72" CB, 84' FOR 96" BE FINISHED TO ASSURE NON -ROCKING FIT WITH ANY L` THAN 2' SHALL MATCH EXISTING. E / GRADATION AND ADDITIONAL INFORMATION. CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48', 54', AND 60' CB; 12" FOR 72' AND 96' CB. COVER POSITION. � 0 0 6. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD (MEASUREMENT AT THE TOP OF THE BASE) cD o a_ 3. TRENCH BACKFILL SHALL MEET A MINIMUM COMPACTION OF 95% DENSITY PER ASTM D 1557. EXCEEDING 2"' SPECIFICATIONS. PRECAST BASE SECTION 8. VERTICAL EDGE OF RISER SHALL NOT BE MORE THAN 2" I� 0 0 FROM VERTICAL EDGE OF CATCH BASIN WALL. 1 r) c 4. IF UNSTABLE MATERIAL IS ENCOUNTERED BELOW PIPE ZONE, CONTRACTOR SHALL REMOVE AND REPLACE AS REQUIRED 7. FINAL PAVEMENT JOINTS SHALL BE NEATLY AND UNIFORMILY SEALED WITH WSDOT STANDARD SPECIFICATIONS 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. O BY CITY ENGINEER. 5-04.3(5)C APPROVED JOINT SEALANT OR APPROVED EQUAL. 0) u) C) .-. 1 LN w �00(D00 / �0-)(DLf) N _,�� REVISION DATE REVISION DATE , REVISION DATE REVISION DATE C Q N CD C'4 o JANUARY 2018 TYPICAL HMA AND FEBRUARY 2020 CATCH BASIN, TYPE 11 OCTOBER 2018 JANUARY 2018 - � o N CITY OF EDMONDS TYPICAL TRENCH SECTION CITY OF EDMONDS UTILITY PATCH CITY OF EDMONDS 48", 54", 60", CITY OF EDMONDS CATCH BASIN TYPE I Z- ..C4 w-a PUBLIC WORKS STANDARD m PUBLIC WORKS STANDARD PUBLIC WORKS 72" & 96" STANDARD ' PUBLIC WORKS STANDARD L< E LU DEPARTMENT DETAIL DEPARTMENT DETAIL DEPARTMENT DETAIL DEPARTMENT DETAIL 0 oz Q oommLL_w APPROVED BY: R. ENGLISH G U - 400 Fs t . 109 3 APPROVED BY: R. ENGLISH G U - 41 0 F t ,' APPROVED BY: R. ENGLISH S D - 3 0 0 s } . 100 APPROVED BY: R. EucLicu S D - 3 0 3 Q CV BLD2021-0356 z CD RESU B (D LU co APPROVED FOR CONSTRUCTION Jun 24 2022 CITY OF EDMONDS m z J CITY OF EDMONDS ENGINEERING DIVISION z - E DEVELOPMENT SERVICES APPROVED AS NOTED DATE: � < o DEPARTMENT ,�// w Q z o yi� ,,A)811112022 BY: w c 3 CITY ENGINEERING DIVISION a a o_j 18"x24" (+1/32", -0" TYP) 9/16" \ I ~ I~ r1-1/2„ + j - 4„ 16"x22" OPENING 3/4" 17-3/4"x23-3/4" +1 32 -0 TYP 25" SECTION A -A 25" 7� 1-2-1/2" 1/2" mA A L M t\ I 0 3/4" . 16 + 3/4" x 2-1/4" x 1/8" PLAN CEMENT CONCRETE CURB PAVEMENT, DEPTH VARIES I --_-_------. ,;r PRECAST ;:;,'. CONCRETE RISERS ::. i CATCH BASIN WALL SECTION B-B VERTICAL CURB OR CURB AND GUTTER B PLANTING STRIP OR SIDEWALt� X � ow w �:ow X D W Z Li m0�L-0 j 0LZi1 CONCRETE Q � GUTTER z m cn L) o�Q U � m o D �w,"i iL��^ ��.: � :w •, �. > �.: ���� •j. i. S �' . ly.. { ��4.... � :n ly,ry .,.:.:-:SEE _;y^ ,,,. ��.'�;:r ;'{?':•_ .C,'.•• 'NOTE`..6..::.�;,. B PLAN , NOTES: 1. DRILL AND TAP FOR, AND PROVIDE, TWO LOCKING BOLTS 5/8"-11 NC STAINLESS TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) BOLTS, 2" LONG. 2. FRAME MATERIAL IS CAST IRON PER ASTM A48 CLASS 30 OR BETTER. 3. SET FRAME TO GRADE AND CONSTRUCT ROAD AND GUTTER TO BE FLUSH WITH FRAME. 4. MATCH CENTERLINE OF CATCH BASIN TO CURB LINE FOR TYPE 1 AND 1-L. 5. VANED GRATE SHALL BE INSTALLED ON CONTINUOUS ROAD SLOPES. HERRINGBONE GRATES SHALL BE INSTALLED IN ALL SAGS AND SUMPS. 6. CURB/CURB AND GUTTER AS REQUIRED BY THE CITY ENGINEER. REVISION DATE CITY OF EDMONDS STANDARD JANUARY 2018 FRAME INSTALLATION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH SD -3 2 0 2' 12" SEE NOTE 1 2-7/8"_ 2-7/8"-I d4 2„ 8,. ° d 4 R=12" a ° 4"-5/8" MINUS CSTC 24" ONLY ROLLED CURB/GUTTER (SEE NOTE 10� (NOT TO SCALE) 2' SEE NOTE 12 6-1/2" 1/2" R SEE NOT[ PAVEME HMA 4" OR MATCH EXISTING, WHICHEVER IS GREATER SEE NOTE 13 6"-5/8" 2"-5/8" MINUS CSTC MINUS CSBC 8-1/4" CONCRETE VERTICAL CURB (SEE NOTE 11) NOTES: (NOT TO SCALE) 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. 3. EXPANSION JOINTS SHALL BE PLACED ADJACENT TO ANY STRUCTURE. 4. EXPANSION JOINTS SHALL BE EVERY 10 FEET. 5. EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE PREMOLDED JOINT FILLER. 6. CONCRETE SHALL BE CLASS 3000. 7. FINISH SHALL BE LIGHT BROOM. 8. CURB SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS. 9. REMOVAL/REPLACEMENT OF CONCRETE CURB SHALL BE FROM EXPANSION TO EXPANSION JOINT, UNLESS OTHERWISE DIRECTED BY CITY ENGINEER. 10. FOR CUL-DE-SAC AREAS AND TO REPAIR LIKE CURBING ONLY, AND/OR AS APPROVED BY CITY ENGINEER. 11. FOR REPLACEMENT OF EXISTING VERTICAL CURBING ONLY AND/OR AS APPROVED BY CITY ENGINEER. 12. A 2 FOOT MINIMUM ASPHALT SAWCUT MAY BE REQUIRED AS DETERMINED BY CITY ENGINEER. 13. ALL VERTICAL EDGES SHALL BE TACKED. 14. NATIVE AND GRAVEL SUBGRADE SHALL BE COMPACTED TO A MINIMUM OF 95% OF MAX. DENSITY. REVISION DATE CITY OF EDMONDS ROLLED AND VERTICAL OCTOBER 2018 CURBS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R - 5 21 w z J RESIDENCE a- 0 CLEANOUT a WITH 45' BEND AND 2' CAP CLEANOUT (MAX) f(TYP) NOT TO EXCEED 100' BETWEEN CLEANOUTS T T P Z a m w w 6 SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. CLEANOU (WYE WI H CA AND CLEANOUT COVER) AND r z CONCRETE LEVELING COLLAR Ul W 0 0 W 12" LOCKING COVER a \ SEE NOTE 3 r12"t FINISHED GRADE w o END OF PIPER GRIPPER PLUG �' N/N N (CHERNE 27061 OR APPROVED ...i� a v EQUAL) j WATER TIGHT CAP J RISER LEVELING COLLAR 45' SEE NOTE 4 /"45*12" PVC SLEEVE 6" RISER4" OR 6SIDE SEWER 6" WYE AND 6" CITY STUB GENERAL CLEANOUT DETAIL 45' BEND 4" OR 6" 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL 3 SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT z a a w LEVELING COLLAR NOTES: O (n SEE NOTE 4 a a Fj LL ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE _ GASKETED. 12"t 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12" PVC PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED SLEEVE EQUAL. 6" RISER - END OF PIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: PLUG (CHERNE 270261 OR APPROVED EQUAL) • IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24"x6" UNDER ASPHALT OR CONCRETE DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP CONCRETE COLLAR REVISION DATE JANUARY 2018 �- CITY OF EDMONDS SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL t I g 9 n APPROVED BY: R. ENGLISH S S- Z O O 10' EXPANSION DUMMY JOINT JOINT ° ° d � � I ° ° 9 4 a d ° L G c q a ° 10' O.C. 5' O.C. PLAN VIEW (NOT TO SCALE) 5' MIN FULL DEPTH 1/2" EXPANSION CURB/GUTTER JOINT MATERIAL SEE COESTD DTL TR-R-520 2% MAX 14 1/2" R d a. a .� 1/2" R d a d d . a ° d a a a a a ° 8if y \- 2„ MIN 5/8" MINUS CSTC ON NATIVE BEARING SOIL SECTION VIEW SEE NOTE 9 NOTES: (NOT TO SCALE) 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. CONCRETE SHALL BE CLASS 3000. 3. FINISH SHALL BE LIGHT BROOM. 4. SIDEWALK THICKNESS SHALL BE 4". 5. SIDEWALK THICKNESS AT DRIVEWAYS SHALL BE 6" THICK. 6. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON-SKID AS SPECIFIED BY ENGINEER. 8. SEE COE STD DTL TR-550 FOR POSSIBLE ROOT BARRIER INSTALLATION. 9. SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. 10. ALL EDGES WITH EXPANSION JOINTS SHALL HAVE RADIUS `S t. 18`J. CITY OF EDMONDS CONCRETE SIDEWALK PUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH Olt' REVISION DATE JUNE 2019 STANDARD DETAIL TR-531 'z w J 1 w z 0OZ 0 dw .0 W aa ION Lnaav �o� QOm NOTES: (IF STUB FOR FUTURE DEVELOPMENT) SEWER STUB SHALL BE LOCATED 10' INSIDE PROPERTY LINE & STAKED. PLACE 2"x4" TIMBER AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO ENSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS, STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2 x 4 STAKE AT OR ABOVE FINISHED GRADE. w Z J w a LOCKING CLEANOUT COVER aPER COE STD DTL SS-200 6" LATERAL SEWER SLOPE - 2% MIN TO 50% MAX 22.5' OR 45' BEND 6" TEST TEE 6" WYE/6" ROMAC SADDLE SEE NOTES 1 AND 2 fPOSSIBLE SEWER MAIN LOCATION 22.5' OR 45' BEND 6" TEST TEE 6" TEE POSSIBLE I SEWER MAIN LOCATION 1. WHEN TAPPING INTO EXISTING MAIN A ROMAC STYLE CB SADDLE SHALL BE USED. PLACEMENT OF TEE SHALL DEPEND ON DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 2. IF NEW MAIN IS BEING INSTALLED OR MAIN IS BEING REPLACED, SERVICE CONNECTION TO THE MAIN SHALL BE DONE WITH A WYE. WYE SHALL BE AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 3. IF CONNECTING EXISTING PRIVATE SIDE SEWER TO NEW CITY LATERAL, A CONCRETE/PVC STRONGBACK FERNCO RC SERIES OR ROMAC COUPLING SHALL BE USED AND SECURED PER MFR'S INSTRUCTIONS. 4. BORING OF SERVICES WITHIN RIGHT OF WAY IS NOT ALLOWED. 5. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 6. IF STUB FOR FUTURE DEVELOPMENT, USE RUBBER JOINT BISCUIT PLUG OR OTHER APPROVED WATERTIGHT PLUG. _ REVISION DATE CITY OF EDMONDS MAY 2018 P NEW LATERAL SEWER PUBLIC WORKS STANDARD DEPARTMENT DETAIL st lguC APPROVED BY: R. ENGLISH SS-202 TRANSITION PANEL DRIVEWAY WIDTH OS STANDARD 1/2" FULL DEPTH CONCRETE 11 EXPANSION JOINTf SIDEWALK Q (TYP) O SEE COE STD DTL TR-531 = w O �I ~O :m N 3 > O3 ;n _� / �w \ o W PLANTER W cn / I o O6 I \W W PLANTER W CONCRETE CURB DRIVEWAY APPROACH AND GUTTER, SEE 3 SIDE SLOPE (TYP) `cICOE STD DTL FLOWLINE OS SLOPE AS NEEDED TR-520 TO MATCH PLANTER DRIVEWAY APPROACH GRADES DRIVEWAY APPROACH WIDTH VARIES O 5' MIN 8'-12' 2' MIN 7 SAWCUT Og 8 r, % VARIES2% MAX SLOPE ROUNDING 6" CONCRETE DRIVEWAY APPROACH 2" 5/8" MINUS CSTC COMPACTED SUBGRADE 10 SECTION A -A NOTES: O1 CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2 CONCRETE SHALL BE CLASS 3000. 3 FINISH SHALL BE LIGHT BROOM. O4 FULL DEPTH 1/2" THRU EXPANSION JOINTS SHALL BE PLACED AT BACK, SIDES AND FRONT. MAXIMUM EXPANSION JOINT SPACING IS 10' CENTER TO CENTER. WHERE DRIVEWAY WIDTH IS LESS THAN 20', EXPANSION SHALL BE PLACED AT CENTER OF DRIVEWAY. O5 DRIVEWAY WIDTHS TO BE CONSISTENT WITH CITY STD DTL TR-541. DRIVEWAY WIDTH DOES NOT INCLUDE ADJACENT RAMPS. O6 A MINIMUM 4' RAMP TO BE INSTALLED UNLESS APPROVED OTHERWISE BY CITY ENGINEER. O7 FULL DEPTH 1/2" EXPANSION JOINT REQUIRED BETWEEN CURB AND DRIVEWAY APPROACH. O8 MAINTAIN 1/2- LIP AT GUTTER ADJACENT TO DRIVEWAY APPROACH. O9 2' ASPHALT SAWCUT MAY BE REQUIRED WITH CURB/GUTTER INSTALLATION. REFER TO COE STD DTL TR-520. 10 SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. 11 INSTALL MINIMUM 5-FT TRANSITION PANEL BETWEEN DRIVEWAYS AND WHEN CONNECTING TO EXISTING SIDEWALK. REVISION DATE CITY OF EDMONDS DRIVEWAY APPROACH JANUARY 2018 TYPE III - PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH TR-543 �I5-1/2 R=1/2" R=1" 1" BATTER �R=1" iv 0.0` 5 FT/FT a iD 4 4 2' MIN SAWCUT SEE NOTE 10 18" STANDARD 6"-5/8" MINUS CSTC SEE NOTE 11 MINUS CSTC STANDARD TYPE "A"STANDARD TYPE "A" CURB/GUTTER (NOT TO SCALE) HMA 4" OR MATCH EXISTING, WHICHEVER IS GREATER SEE NOTE 12 NOTES: 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. 3. EXPANSION JOINTS SHALL BE PLACED ADJACENT TO ANY STRUCTURE. 4. EXPANSION JOINTS SHALL BE EVERY 10 FEET. 5. EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE PREMOLDED JOINT FILLER. 6. CONCRETE SHALL BE CLASS 3000. 7. FINISH SHALL BE LIGHT BROOM. 8. CURB SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS. 9. REMOVAL/REPLACEMENT OF CONCRETE CURB SHALL BE FROM EXPANSION TO EXPANSION JOINT, UNLESS OTHERWISE DIRECTED BY CITY ENGINEER. 10. A 2-FT MINIMUM ASPHALT SAWCUT MAY BE REQUIRED AS DETERMINED BY CITY ENGINEER. 11. CURB/GUTTER SHALL BE 18" OR AS DIRECTED BY CITY ENGINEER. 12. ALL VERTICAL EDGES SHALL BE TACKED. 1BL3- 1/2" EXI JOINT MA 4" MIN-6" MAX 3' x 3' x 3.5" THICK CONCRETE PAD AROUND HYDRANT 1 CY 1-1/2" WASF ROCK. 1' MIN ABC DRAIN HOLES AND AROUND HYDRANT 1 BOTTOM OF DITCH I COVER TOP AND SII WITH MIRAFI 160N I APPROVED EQUAL. REVISION DATE CITY OF EDMONDS CONCRETE CURB JANUARY 2018 AND GUTTER PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R - 520 fMOUNT HYDRANT PLUMB PROVIDE 3' MINIMUM CLEARANCE AROUND HYDRANT I 4" STORZ ADAPTER DOUBLE SIDED BLUE ROAD '10 MIL PLASTIC UNDISTURBED EARTH �` �����/ BETWEEN BLOCK & TEE 12"x12"x4" CONC. BLK. 12"x12"x4 2" MIN CONIC BLK CLEARANCE HYDRANT CONNECTION PIPE TO q BETWEEN BE DUCTILE IRON CLASS 52. v •: ' BLOCKING ANY INTERMEDIATE JOINTS TO BE AND RESTRAINED .y t: :a BOLTS THRUST •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o(o U) C I m N li Z O O N W Q T o m w � p W w Lljz w : Q W = o � a_ o Q V) 0 0- Q m Q J W C.) 0 Q Q V vJ n T W L U 0 00 g 00 0 _ Z = N W ~ N C,4 V) ZLo Q > w O N Lo v Q M V) i C V) (n H W W :2 W O0� _ I- 0 Z = H Q 0 0000 � N � o I o Z Z w OHO 00 :2 N x 0 0 M "IQ • a� c E �j 00 0 O IL 0 I t O C) 0 N704 I"-)0)® 00 I LLo 0 ++0L N co� C z _j I�=Z J O O= X Q oOG7�LL_ W C� BLD2021-0356 z R E S U B APPROVED FOR CONSTRUCTION W (D � LU J u n 20022 CITY OF EDMONDS m z CITY OFEDMONDS ENGINEERING DIVISION 0 z - DEVELOPMENT SERVICES APPROVED AS NOTED DATE:CL DEPARTMENT ,,,,, w Q �D/��"' -8/11/2022 BY: � o W CITY ENGINEERING DIVISION 0 I M GROUND/ROADWAY 22- MAX* PROPERTY ;H GRADE LINE O �— GROUND/ROADWAY DRILL HOLE FOR LOCATOR WIRE. II °' II PROVIDE 12" MIN OF WIRE IN VALVE BOX II II oil V I II II II II II N II II U IJ E L R L 2 ° �- �o QJ * SERVICE TAP TO MAIN SHALL BE ANGLED AND NOT EXCEED 22 DEGREES MATERIAL LIST: O 2" (IP TAP) DOUBLE STRAP SADDLE EQUAL TO O WHEN REPLACING EXISTING SERVICES: ROMAC STYLE 202'S EQUAL TO FORD VBB87-12HB-1177 O 2" BRASS IP BALL CORP WHEN PLACING NEW SERVICES (HIGH BYPASS): EQUAL TO FORD VBH87-12HB-1177 O 2 - 2" BRASS STREET ELLS FOR SWING JOINT O METER BOX ARMORCAST A600164OPCX18, WITH ARMORCAST LID A6001947TRC1-H7 OR APPROVED O REHAU MUNICIPEX PIPE (2") WITH STAINLESS STEEL INSERT EQUAL STRAIGHT WALL POLYMER BOX (NO MOUSEHOLES) WITH 20K COVER WITH HINGED Cl EO 2" MIPT X CTS GRIP FITTING READER FO TRACER WIRE: #12 AWG, SOLID COPPER CLAD STEEL, HDPE O 2" BRASS PIPE (L.T.F) COATED. CONNECTION AT THE METER SETTER SHALL BE MADE WITH AN ALL STAINLESS STEEL HOSE CLAMP. O SCHEDULE 40 2" PVC CAP OR PLUG REMOVED CONNECTION AT MAIN LINE WIRE SHALL BE MADE WITH A WHEN CONNECTION MADE TO CUSTOMER SPLIT -BOLT CONNECTOR. STRIP COATING PRIOR TO CONNECTION. WRAP WIRE AROUND PIPE. O 4"x4"x8" CONCRETE BLOCK SUPPORTS GO BACK SIDE OF METER BOX SHALL BE SET AT THE 0 2" RESILIENT WEDGE GATE VALVE (FIP x FIP) WITH PROPERTY LINE UNLESS APPROVED BY THE CITY ENGINEER. 2" AWWA OPERATING NUT METER BOXES SHALL NOT BE SET IN DRIVEWAY AREAS UNLESS LOCATION AND TRAFFIC RATED BOX IS APPROVED OP 2 PIECE VALVE BOX - TOP SECTION TO BE RICH BY CITY ENGINEER. 940 STYLE 18" WITH REGULAR BASE SECTION LENGTH TO FIT HO 2" BRASS ELL O METER SPACER TO BE SUPPLIED AND INSTALLED BY ® WATER SERVICE TO BUILDING INSTALLED AND CONNECTED TED AT METER SETTER BY THE CONTRACTOR. SPACER MUST HAVE A MINIMUM OF VIA COMPRESSION FITTING 8 - 1/4" HOLES DRILLED IN SPACER BODY. NOTE: PROPERTY OWNER RESPONSIBLE FOR PURCHASING O 2" MIPT X I.P. COMPRESSION FITTING 1-1/2" OR 2" METER THROUGH THE CITY DEVELOPMENT SERVICES DEPARTMENT. THE CITY WILL SUPPLY METER AFTER PURCHASE FOR CONTRACTOR INSTALL. IF 1-1/2" METER IS USED CONTRACTOR WILL SUPPLY REDUCERS TO CONNECT METER. CITY OF EDMONDS ` 1ooh4 PUBLIC WORKS F lay.: w 0 z w 111 U. m DEPARTMENT REVISION DATE 2" WATER SERVICE JANUARY 2021 (FOR 1 —1 /2" & 2" METERS) STANDARD D ETAI L APPROVED BY: IL ENGLISH WA— 1 3 1 4 O 4 I I I I `�.• M !J/fir----------------y -------------------- '�----------------��'is !r'F=====--------� -- r----- --_-- --- --___ --' F----- --__------- I l l4 rf ! fl ft I I I I I I I I 11 11 4f rf t' I I I 11 11 I1 f' 11 I' If II I I I I I I 11 11 1t 1 1t II II III If 1t II Iffi i i i 1i 11 if 11 ll 11 11 '11�----------------J I I L------------ _U U --- U_ — -- ——fIG I J U if it (, 11 —--------------- i ---------------------� ---------------Jflrf — F---------------,/ /if I I I I I I J 26 3116" 27� ri 3/�ri I 1/2" 3/8 I SECTION O J w 0 0 z ly w IL m 4' - 0 MIN. SEE CONTRACT PLANS \� 3/8" EXPANSION JOINT (TYP) - SEE STANDARD PLAN F-30.10 LANDING , CURB AND GUTTER , CURB RAMP J 4' - 0" MIN. - SEE CONTRACT PLANS FACE OF CURB SE 1 /4, SEC. 31, T. 27 N., R. 4 E., W.M. NOTES 4'-01' MIN. - A _ EXPANSION SEE CONTRACT PLANS 1 At marked crosswalks, the connection between the landing and the 3/8" (IN) PEDESTRIAN CURB - JOINT (TYP) - SEE PEDESTRIAN CURB - roadway must be contained within the width of the crosswalk markings. SEE NOTE 9 B STANDARD PLAN F-30.10 LANDING SEE NOTE 9 2. Where "GRADE BREAK" is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. SIDEWALK 3. Do not place Gratings. Junction Boxes, Access Covers. or other appurte- * , C nances on any part of the Curb Ramp or Landing, or in the Depressed SIDEWALK Curb and Gutter where the Landing connects to the roadway. 3" R. 4 See Contract Plans for the curb design specified. See Standard Plan _'''• F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter. and CURB AND GUTTER Pedestrian Curb details. `CURB RAMP CURB RAMP DETECTABLE WARNING SURFACE - 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. DETECTABLE WARNING SURFACE - 4' - 0" MIN. - SEE STANDARD PLAN F-45.10 See Contract Plans for width and placement of sidewalk. SEE STANDARD PLAN F-45.10 SEE CONTRACT PLANS 6. The Bid Item "Cement Concrete Curb Ramp Type does not include FACE OF CURB DEPRESSED CURB AND GUTTER DEPRESSED CURB AND GUTTER i _" the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, CROSSWALK CROSSWALK Pedestrian Curb, or Sidewalks. T The Curb Ramp length is not required to exceed 15 feet (unless otherwise shown in the Contract Plans). When applying the 15-foot max. length, PLAN VIEW DETECTABLE WARNING SURFACE- PLAN VIEW the running slope of the curb ramp is allowed to exceed 8.3%. Use a single TYPE PARALLEL A SEE STANDARD PLAN F-45.10 TYPE PARALLEL B constant slo e from bottom of ram to to of ram to match into the sidewalk P P P p 4-VMIN over a horizontal distance of 15 feet. Do not include abutting landing(s) in SEE CONTRACT PLANS GRADE BREAK the15-foot max. measurement. When a ramp is constructed on a radius, the 15-foot max. length is measured on the inside radius along the back of the 1O CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN F-30.1 a SLOPE walkway. FOR CURB RAMP LENGTHS GREATER THAN 8'- 0"PROVIDE :r TT COUNTER TOP OF CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. OC. C * _ 5.0% MA)(' ROADWAY 8. Curb Ramps and Landings shall receive a broom finish. See Standard Specifications 8-14. LU DEPRESSED CURB AND GUTTER - 9. Pedestrian Curb may be omitted if the ground surface at the back of the CEMENT CONCRETE PEDESTRIAN LANDING SEE STANDARD PLAN F-10.12 Curb Ramp and/or Landing will be at the same elevation as the Curb CURB - SEE NOTE 9 > �^_ ` AND NOTE 6 Ramp or Landing and there will be no material to retain. SECTION I, A ' 4' - 0" MIN 15' - 0" MAX. (IYP.) LEGEND v SEE CONTRACT PLANS SEE NOTE 7 SLOPE IN EITHER DIRECTION SIDEWALK SIDEWALK 15' - 0" MAX. (TYP.) 4' - 0' MIN. 15' - 0" MAX. (TYP.) GRADE BREAK 1.5% OR FLATTER RECOMMENDED FOR SEE NOTE 7 SEE CONTRACT PLANS SEE NOTE 7 GRADE BREAK CL .. DESIGN/FORMWORK (2% MAX.) GRADE BREAK -\ !� * ,i�r *4 * FORMWORK 8 3R MAXOM SEERECDED NOT 7 DESIGN/ GRADE BREAK 11 �. a , , CURB RAMP LANDING 3/8" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 SECTION O (ALONG INSIDE RADIUS AT BACK OF WALKWAY "CEMENT CONCRETE CURB RAMP TYPE PARALLEL All PAY LIMIT - SEE NOTE 6 SECTION CO CURB RAMP ISOMETRIC VIEW TYPE PARALLEL A PAY LIMIT PEDESTRIAN CURB - , LANDING SEE NOTE 9 NOTES 1. For use with Circular Frames (rings) detailed in Standard Plan B-30.70 2. Slotted Manhole Covers are intended for use with Drywells only. See Standard Plans B-20.20 and B-20.60 3. See Standard Specification Section 9-05.15 for additional requirements ISOMETRIC VIEW H E1L pF wASy�Nco2�, �0 9e� 11 19 IZJ � F S ssyONAL Feb 20 2018 12:56 PM CIRCULAR GRATE STANDARD PLAN B-30.80-01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION _ caq—w, J"tT Feb 27 2018 It 01 AM . STATE DESIGN ENGINEER Washington State Department of Transportation CURB RAMP SECTION `J (ALONG INSIDE RADIUS AT BACK OF WALKWAY) "CEMENT CONCRETE CURB RAMP TYPE PARALLEL B" PAY LIMIT - SEE NOTE 6 T ISOMETRIC VIEW TYPE PARALLEL B PAY LIMIT 3/8" (IN) EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 N'ASZ�lf �� Oy 9/ 1, <�' O� 9� 28680 �o F ASTER JSIONAL Zeller, Scott Jun 24 2016 7:19 AM � ss, PARALLEL CURB RAMP STANDARD PLAN F-40.12-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpenter Jeff �. Jun 29 20i6 2:27 PM STATE DESIGN ENGINEER Washington State Department of Transportation FLOW CONTROL � STRUCTURE �I 4.5" — I PVC PIPE* NON -SHRINK GROUT 1'-0" MAX ` CONTROL DEVICE ASSEMBLY TO BE COUPLING PVC PIPE ; REMOVABLE FROM (OPTIONAL) STUB* ;: I INSIDE THE FCS SET SCREW TO PREVENT ROTATION JL _ INVERT* GASKET (TYP) Z Q PVC PIPE PVC ADAPTER* W/ CROSS* o DOUBLE GASKET I I AND ADHESIVE BONDED SAND FINISH ON EXTERIOR. MIN 7" LONG DRILLED ORIFICE IN PVC INSIDE CAULK SPACE BETWEEN CAP PLUG PVC ADAPTER AND PIPE STUB CONNECTION & CONTROL DEVICE ORIFICE DIAMETER* DETAIL A CONNECTION AND 0- LADDER OR HAND HOLDS CONTROL DEVICE POLYPROPYLENE (SEE DETAIL A) OUTLET PIPE ALLOWABLE OUTLET LOCATION - (180' to 315' ) FINISHED GRADE V-NOTCH WEIR AS NEEDED* OVERFLOW ELEV* SUPPORT (2 REQ'D) fCATCH BASIN TYPE II PER COE STD DTL SD-300 ADDITIONAL ORIFICE AS NEEDED* l'-O" MIN l'-6" MAX EL* r PVC PIPE* TEE* SPOOL* ELBOW* I DRILLED ORIFICE DIA* PVC INSIDE CAP PLUG* CINCH ANCHOR WIRE ROPE CLIP (SS) DEFORMED 3/8" STEEL ROD (SS OR t' + ALUMINUM) LENGTH TO FIT '' PVC PIPE & CROSS FLOW CONTROL CONTROL DEVICE �j I I STRUCTURE SEE DETAIL A I DETENTION PIPE PIPE SUPPORT ' (LENGTH, DIAMETER, DETAIL B DIAMETER* MATERIAL TYPE)* FLOW CONTROL STRUCTURE SHOWN W/ TYPE 2 CATCH BASIN (DETAILS A & B SHALL APPLY TO ALL DESIGNS NOTES: WHERE A SHEAR GATE WOULD OTHERWISE APPLY) * SPECIFIC DESIGN INFORMATION AS INDICATED ON APPROVED CONSTRUCTION DRAWINGS. INVERT OF DETENTION PIPE IN STRUCTURE SHALL BE EQUAL TO OR HIGHER THAN THE INVERT OF THE OUTLET PIPE. PRIVATELY -OWNED CONTROL STRUCTURES SHALL NOT BE PLACED IN CITY RIGHT-OF-WAY. 18y CITY OF EDMONDS PUBLIC WORKS DEPARTMENT REVISION DATE FLOW CONTROL JANUARY 2018 STRUCTURE (FCS) STANDARD DETAIL APPROVED BY: R. ENGLISH S D - 3 01 N O = Q N (O U) a- O 1 m N o0 LI- Z O 0 w a m o w z 0 Li w 0-, LIJ m = Q U o fn o Q r� > I'1 Q m U) Z O_ 07 W W Q O Z n 'r! W 0 0 g00 ao 11CID _ Z=�N LIJ ~ =�=1 N N V)� zl�LID Q Ln w 0 N W W :2 W 0 CK Z 0 00 ~ N o I o Z Z 000 w :2 N X DOD D_ LIJ 00 LIJ BLD2021-0356 RESU B APPROVED FOR CONSTRUCTION Jun 24 2022 CITY OF EDMONDS CITY OF EDMONDS ENGINEERING DIVISION o DEVELOPMENT SERVICES APPROVED AS NOTED � DEPARTMENT DATE: Q BY: ` 110�1 8/11/2022 CITY ENGINEERING DIVISION � U C° o I� o I = 1� O 0 O N >' rnC9) �00(0Co �0)Otn O N (D +- C � v LU Z J W � -R Ld = Z J O O= x OOma- Lai W i 0 <: N O 0 (I W %-a w E w o to rnto a) a) � I ,2 E N a) o S / 99 \i 00 ROAD ONE LANE WORK ROAD AHEAD AHEAD A� W20-1 W20-4 X=100 5 ROAD ONE LANE ROAD WORK AHEAD AHEADlk W20-4 W20-1 G20-2 END ROAD WORK II 6 DEVICE MI 1 _ 238th ST SW \ ® ® SE 1 /4, SEC. 31, T. 27 N., R. 4 E. W.M. � I O 142' I V Id I °� 122' TAPER �, I6 DEVICE MIN h--+ At co k® I cf J ® 0T ® � —� I go,< 13 —® X=100' 73' 1 J - I a 9 II W20-7A I I I I I I - WEST BOUND PIPELINE EXCAVATION / us 99 G20-2 / END ROAD WORK /A 01err 238th STREET SW' \ 15' X= 100 113 TAPER 6 DEVICE MIN N W20-7A EAST BOUND PIPELINE EXCAVATION us 99 R 19 SIDEWALK -1 1 a RT) CLOSED CROS~ 238th STREET SW EqQ E ate\\ END ROAD WORK G20-2 I Ixl I NV ONE LANE ROAD sr� R AHEAD I X=100' W20-7A X=1 QO' W20-4 v � � • I � I I Q) G A� DO =1 1 12I-1 W20-7A JN_=_l _0 — —w I o0 r me I I I 7l tx� ONE LAN ROAD R AHEAD W20-4 X=100' I - ROAD V I R19-1 1 a(LT) I I WORK SIDEWALK CLOSED AHEAD o X� .�� °o "�! CROSS HERE 130' W20-1 N 0, FRONTAGE WORK &SIDEWALK CLOSURE CHANNELIZATION DEVICE SPACING (FEET) MPH I TAPER TANGENT 25 30 110 TO 20 40 NOTES 1. ALL SIGNS ARE BLACK ON ORANGE. 2. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS SHOULDER IS RECOMMENDED. 3. NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR ADDITIONAL DETAILS. 4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. "l1 / LEGEND FLAGGING STATION TEMPORARY SIGN LOCATION PROTECTIVE VEHICLE ® ® ® ® CHANNELIZING DEVICE WORK AREA NOTE: TRAFFIC CONTROL BASED ALL TRAFFIC CONTROL SHALL ON WSDOT TC-1. COMPLY WITH MUTCD STANDARDS X=100' "ROAD WORK AHEAD l\ / W20--1 I ROAD WORK AHEAD W20-1 0 40 RESUB Jun 24 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT w cn 0 0 oD I ao � z o O N w 0U�oQ LLI J W � m z Q o w p W LL.I U, 0 Q m w Q 0 0 z w V) w `o U r- 00 g00 0-Cy) = N z ~ Ld N C4 zL0 Z Q _ � Ln w UI��N M c) Q V) 07 LdLd `W L Ids O� z= Q 0 00 NV) V) o I o w z z o0,o D :2 N :2 MOM � �f N N S� O o _YI Pew C N o �, C, a L CD E / O 0 P7 U o O O � O C- + IO ® rn � w / �0(� ��o� a, Q� O N (c) 00 <�^� o 0 a o N 1 "=40' `U J D N > Lizww� I�2Z J Q E /o (oo0a: 80 120 160 00m0_liw BLD2021-0356 z EN o W "N APPROVED FOR CONSTRUCTION LU CITY OF EDMONDS m z J ENGINEERING DIVISION o Lii— z DATE' APPROVED AS NOTED Q Z Q) �8/11/2022 w Q Z rn0 BY: Or CL w o a CITY ENGINEERING DIVISION o�