Loading...
FIR2024-0069+Fire_Sprinkler_Equipment_Specification_Sheets+8.14.2024_1.37.30_PM+4440733FIR2024-0069 RECEIVED Aug 15 2024 PLANNING & DEVELOPMENT DEPARTMENT FIREPROTECTION Shen -Federman Residence 2019NFPA13D 23310 Humber Lane Edmonds, WA 98020 Material Specifications 113 Cherry St, PMB #41900 (425) 271-5598 State Contractor's License Seattle, WA 98104 # MOOREFP116NP THIS PAGE INTENTIONALLY LEFT BLANK Page 1 of 5 cR; FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS �&UL Listed (C-UL-US-EU): Category VKKW EU Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom' Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 2 of 5 cR; FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/z" ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)3 Number' Number' Number° Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Red Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Maximum ambient temperature for cover assembly is 100 °F (38 °C). Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. e The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F_012116 17.04.20 Rev 17.2 Page 3 of 5 cR; FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number I SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage 6 Flow GPM Pressure Listings and Minimum Area (LPM) PSI(bar) Deflector to Installation Approvals3,s Spacing Ceiling Type Ft. 155 °F (68 °C), 200 °F (93 °C) Temperature p 4 ` Ft. X Ft. (m) (m X m) Rated Sprinklers U 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Refer to Figure 2 Concealed with Cover Plate See Footnotes 7,10, & 11 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Assembly. See Footnote 9. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. s This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 2008. e For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). s Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 0 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 9. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_012116 17.04.20 Rev 17.2 Page 4 of 5 cR; FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** ^0W Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) neter opening aired in the ing. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 17.04.20 Rev 17.2 Page 5 of 5 cR; FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT 1 E c 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum Figure 2: Sprinkler Dimensions and Cover Installation All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers 2-3/4" (70 mm) or 3-5/16" (84 mm) - -' ' - \- . ......I Figure 4: Square Cover Assembly 15394 Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) RD13 P POTTER Residential Riser with Capped A The Symbol of Protection Flowswitch Port Features • Pre -assembled and pressure tested • Available in 1",1 1/4", 1 1/2", & 2" nominal pipe size models • Female adapter ships loose so riser can be installed in a confined space • Fits in standard 2 x 4 construction walls • Easily removable flowswitch port cap for installation of VSR- SG Flowswitch (VSR-SG not included) • Includes 3 way valve to allow for calibration of pressure gauge Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Description The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard® CPVC pipe and Spears® CPVC fittings. The RD13 Riser incorporates a connection for a VSR-SG flow switch, gauge, and drain/test valve. The connection for the VSR-SG flowswitch is capped with a union connection to facilitate the installation and removal of the switch in confined spaces at a later date. Installation 1. Using appropriate sealant, thread the female adapter on to the main water supply. Then glue the riser assembly to the female adapter. Pipe the drain connection to an adequate drain location capable of handling the drain discharge. The riser can be mounted in the horizontal or vertical position. The waterflow switch connection must be located on the top or on the side of the pipe when installed in the horizontal position. This will prevent debris from entering the throat of the waterflow switch which could interfere with proper operation. 2. Following CPVC manufacturer's instructions for preparation and gluing of CPVC piping systems, glue the main riser to the main supply line for the sprinkler heads. Note: All glued connections must be completed and cured before the flowswitch is installed. 3. A thread sealant shall be used in making threaded connections. Teflon® thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC. For other types of thread sealants, which have been specifically investigated and confirmed to be "System Compatible", refer to www.spearsmfg. com. Attach gauge to riser. Apply Teflon® tape to male fitting of gauge only. See Fig 1. Riser Technical Specifications Dimensions See Fig 1 Service Pressure 175 PSI (12,07 BAR) - UL Environmental Limitations Temperature range: 40°F-120°F (4.5°C-49°C)- UL Specifications subject to change without notice. Service Use Automatic Sprinkler NFPA- 13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 British Standard BS9251 A CAUTION Do not over -tighten the union nut, hand tighten only. Use of a wrench may cause damage to the union nut. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5401579 - REV B • 11/18 PAGE 1 OF 2 RD13 @POTTER Residential Riser with Capped The Symbol of Protection Flowswitch Port Dimensions (See Chart Below) Fig I t NPT Adaptor (Shipped Loose) 3 1/2" Gauge (Shipped Loose) 1" NPT — Drain Valve Itch *RD13 Risers (ASSEMBLED DIMENSIONS) Size Model Number Part Number Dimension "A" Dimension `B" Dimension "C" Dimension "D" Dimension "E" Dimension "F" (in) (mm.) (in.) (mm) (in) (mm.) (in) (mm) (in) (mm) (in) (mm.) 1" RD13 Riser w/ Cap 1" 1119068 19 483 15 3/4 400 18 457 14 5/8 371 121/4 311 10 1/2 267 1 1/4" RD13 Riser w/ Cap 1.25" 1119078 19 5/8 498 16 1/2 419 18 1/2 470 15 3/8 391 12 1/2 318 10 5/8 270 1 1/2" RD13 Riser w/ Cap 1.5" 1119088 N/A N/A 16 3/4 425 N/A N/A 15 5/8 397 12 3/4 324 10 3/4 273 2" RD13 Riser w/ Cap 2" 1119098 N/A I N/A 1 18 1/4 464 N/A I N/A 16 7/8 1 429 113 3/8 1340 1 11 1/8 1 283 Ordering Information Ordering Information Nominal Pipe Size Model Part Number V RD 13 Riser w/ Cap 1" 1119068 1 1/4" RD13 Riser w/ Cap 1.25" 1119078 1 1/2" RD13 Riser w/ Cap 1.5" 1119088 2" RD 13 Riser w/ Cap 2" 1119098 Optional: VSR-SG, stock no. 1144460 Gauge and NPT Adapter shipped loose in box. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com iso sooi:zoos DESIGNING, MANUFACTURING, & DISTRIBUTING QUALITY SYSTEMS 5401579 - REV B 11/18 PAGE 2 OF 2 tqC00 BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified M EA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Worldwide I Contacts I www tyco-fire.com Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900. Page 1 of 2 AUGUST 2018 TFP1915 TFP1915 Page 2of2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. 1400 Pennbrook Parkway, Lansdale, PA 19446 l Telephone +1-215-362-0700 Otto 6 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls BLAZEMASTER is a trademark of The Lubrizol Corporation P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER/RESTRAINER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - D@05 203 - EX 4231, EX 2551 LISTED ALTERNATIVE FOR #500 Pipe Strap 510 Fastener SIZE Dim. rt. - rt 3/4 2.125 1 2.312 1 1/4 3.170 1 1/2 3.400 F2 2 4.010 1/2 4.0 3 5.320 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Hanger for steel pipe at 15' spacing per NFPA 13. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL D 4D Ds FASTENERS PER NFPA 13 - See table. LISTED FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. Han; uaeo MOUNTING FASTENERS Pipe Wood Wood - Thra 5/8" Gyp Steel — mi.. is GA. CPVC #905 or #10 x1 SMS #14 x 1 1/2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 x1 1/2 SMS or 1/4 x1 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS = Sheet Metal Screw LS = Lag Screw TeG— k=Tek GypScrewsum Buard AFCON #905 screw - custom 5/16" hex head. Restraint Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable order any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. lbilize 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - "OUSTED" 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL -@-s FASTENERS PER NFPA 13 - See table. usrso FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. MOUNTING FASTENERS Pipe Wood Steel — Mfn.la GA. CPVC #905 or #10 x1 SMS #14 or 1/4 Tek Copper #905 or #10 x1 SMS #14 or 1/4 Tek SMS = Sheet Metal Screw Tek=Tek Screw AFCON #905 screw - custom 5/16" hex head. Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 11 ' 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET HANGER & RESTRAINER CPVC - COPPER - STEEL SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - c 9. usrro 203 - EX 4231, EX 2551 Size 3/4 - 1 1/4: Fastener spacing fits on wood 2 x 4 Installation - Backing Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastene PATENT - No. 6,648,278. FUNCTION - Hanger for support of CPVC or copper pipe. Hanger for steel pipe at 15' spacing per NFPA 13. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. Hanger/ INSTALLATION - Per these instructions RestrainE including NFPA 13, 13R, 13D and CPVC manufacturers. Snap over pipe then squeeze strap back allowing pipe to slide freely. When fastener threads are exposed through wood, install backing nut - See drawing. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL - 41. -s FASTENERS PER NFPA 13 - See table. LWED FEATURES * 1 1/2" Offset * Common center -line for 3/4" and V * Offset edge eliminates abrasion. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. ® 4k " MOUNTING FASTENERS nm�n Pipe Wood Wood - Thru 5/8" Gyp Steel - Min. 18 GA. CPVC #905 or #10 x1 SMS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 x1 1/2 SMS or 1/4 x1 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS = Sheet Metal Screw LS = Lag Screw Gyp-- Gypsum Board Tek=Tek Screw AFCON#905 screw - custom 5/16" hex head. 1.50 r Hanger/Restrainer Hanger/Restrainer �bilize Specific AFCON products are exclusively designed to be compatible ONLY with other AMON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. CAD 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 DOUBLE OFFSET HANGER & RESTRAINER CPVC SIZE -SYSTEM PIPE: 3/4" and 1" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - `@"' 203 - EX 4231 PATENT - No. 6,702,236 FUNCTION - Hanger for support of CPVC pipe. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. INSTALLATION - Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers. When fastener threads are exposed through wood, install backing nut. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL D& FASTENERS PER NFPA 13 - See table. LSTED FEATURES * Double 1 1/2" offset with common pipe center -line. * Offset edge eliminates abrasion. * Pipe bore provides robust support for rough job conditions. * Pipe slides easily through bore. ORDERING - Part # and pipe size. Hanger/Restrainer Hanger/Restrainer D 41 DD MOUNTING FASTENERS LISTED CPVC Pipe Wood Hanging/Vertical Restraint #904 or #14 xl 1/2 SMS Horizontal Restraint #904 or #14 xl 1/2 SMS SMS = Sheet Metal Screw * AFCON#904 Screw - custom 3/8" hex head. Specific AFCON products are exclusively designed to be compatible ONLY with other AMON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/16 CAD7