REV1 FIR2024-0067_Fire_Sprinkler_Plan_10-28-2024_22_00_51_2401_10429_240th_PL_SW_FSD_V2.CI,M-W 5fA11C-VAfR l
5TAX: 95 PSI
EXt101; WAIL
51R M1R
RA - 00 ELEV-100'
1" NCR
70' OF
MN". �" 1" C�r ` `� 1055Ei01N� i ,11 1.5" POLY
I��Ea,ww
I00 _
Elt:li- 09,
"I-1/ 2" F'EX
TO 5Y51fM
��- MINIMUM "/ 4" 5Y50
PMN
T PLUVI6IN6 FIXW5 NOf
9 Md ON 5M%R LOOP
0 ~� FU.L rX
O&L'4VE
EIEu-I1
SENJU Model CN-RES Concealed Pendent Sprinkler K=4.9,
mmmm26 162 F, 7/16 Orifice, Maximum Spacing 16 x 16 Sprinkler
SS8421 Head demand 15 gpm @ 9.40
SENJU Model CN-RES Concealed Pendent Sprinkler K=4.9,
IN IN IN an 162 F, 7/16 Orifice, Maximum Spacing 18 x 18 Sprinkler
SS8421-18 Head demand 19 gpm @ 15.00
PIN
f-.P. 1'Lut z a/ X — — — — TO E-XI T MT _
6050 X SLDR. 6060 O Ro�^ANL E 6060 ><O A ,
(iCS"Rr ) SLDR. Fj-UE WITHIN ROIOP *ATIO SLDR. Q — — — —
9 FIRST FLOOR
18 SECOND FLOOR
27 TOTAL
TO F,tT f'ROI--CIN
CLEARANCE Iw
p1N LL*46
O —
a -I 4XIO � III
10-1/2" .L.B, I I r'-3 4 10
H104
— -� —
4X
r <� �i <� Lt a!I tv I 1
I 2ERo CT- G-1=/r�
I I I I I I 1 l a IF vr�NT I I
bA5 F IKEP I I
II I I ryd
I t✓�s - I I ' -
I p� I x - - -
11 r.A ►-i- t � H102 = -
ej_ I H10 1201
�� o -
.:: 91 _ _
rOhY — _ _ - � I I N�1-1JT I iI = I
- I I Iale 4'
GG .T►'
MCI. w. v.T c
A5 AB .
i h P4 tI
I 1 r;l
I I I I I I I F O N6_
4x10ZA:I L IN
a r III
o __ I I I I I I .• H 10 7 - �.
rur I �- 108 ,�� I I= a�
W
irI I I I
_tz
-- -- -- -- - — �nwl
X. FOYER
I ;v� I tit r tc. I _
F' I ILfWt� - - F — —
FOROPT.z q 1 L
I 4 II^I'S C (n L— — — — — — - — — —
18" TK4U55E5 ® 24" c7_G S,1
NOTE:
EN r UN��5�5 OTI� r2vdlS� KOreV VALVE
Oz
-.� F r I = � m Rue - - - - - - - -1 1/2" AQUAPEX FROM S.I TO
109 MAIN SPRINKLER LOOP
-
II Pressure Regulating Valve
PI-4"
6046 XO 5LDR.
(E& ESS) W/
6020 TRANSOM
SET 6046 2101
MAIN FLOOR PLAN
SEE GENERAL NOTES
a0 L1001
UNIT ds4P
L1 Installed on Water Source
For A 25 PSI Differential
I I.
_ I- I NF OF O.H_ C>OOR_
IN JPRI(SHT POSEPITION
I ' rF—'
_ T#1L•SS _ _
r
I LIN�t- rLc�vt� AL�Vr ,"I, I f3c�F�c� O.I I ,
-
I I 4X12 II'-O" LONG
� 80 c..H. G FdAG >7 OFl
SCALE: 1 /4" = 1'-0"
1
L
I G
IFAN
VTO
H211
O 5LDR.
ESS)
1[4>00
� 0
BEDROOM
TV140 2M
r r
�Im
so gni
;I P -If 5
i
MULflFUFr05F FIFE 5PPINKLEI? 5Y51FM:
• 5MIWI.Fp 5Y5TFM TO R INSTAlW IN COWINAT10N W1TH THE
Ca19 51I7F OF TIf 190MF5T1C WEAR E WATEV 5Y5TEM.
• 5MIPYLFp 56TUM 19F516W9 TO TIME 2019 FrAT10N OF TIf
WPA I]W 5TANI9AIW.
• TH15 9UCa5fR9 LAYOUT" 15 6A5Irl? UPON INFOt;MAT10N
MOVIM19 PY MI;5. CKq"5 IN CON5TVUCT10N M FIELD
CONI9IT10N5 MAY OCCLP, WHICH MAY ITOUIPY CHANGF5 TO THE
LAYOUT. IT 15 TIf IT5r 0N5IPIWTY OF TIC WT&LFI; TO NOTIFY
-14
COLOF/ LINFfTF LFGFNn
N,UF LINF5- FEW TO FIXTUtT5 (6ATH, 5HOMr, FTC.).
LlACK LIW5- 5r ONKLFp IfAP TO 5rI;INKLFV WAV.
x 1 / 2" rlrE 51ZE
3/ l" r1rF 5IZF
i p 1" rIrE 51ZF
ix 1-1/ 411 plrE SIZE
} I -1 / 2" rIr'F 51ZF
M05f HYM U.ICALLY ITMOTE HFAI?5
HFAI? # 6rm pE5511 1T(2 C AT STD =1-
I FEAT? H214 18 39.980
2 HFAI? H211 & H212 30 40.346
ANY hFA125 a 1'1l'IN6 INSfALI.Fb IN LINCONbMONEC
5�'ACE fO 6E PRO1''FKI.Y INSU.ATEb. If 15 THE
FFSf'ON51611.11Y OF THE INSfALI.EF fO pPOV117E A
CONSfANf NFAt SOLFCF f0 MAINTAIN A MINIMUM
1FMPEKATUkT OF 40° F.
CONCr&W APAPV FITTING MOLNTIN6 Prf&
FJ.i.S.
U. LISTED MINIMUM CUT L%6TN
F-1960 Fp TFF CIF TIDING: 3-I/ 2"
4" nx From L00p TO MAXIMUM CUT L�NMTH
FIf, 5KINKLFP ADAPSP, OF WIN6: I2"
2LIMLE F-1960
5PIW,LW VAMP
FIFLD VFpIFY FINI5HFI?
CEILING MAVIAL
TO PF,1UPMW MOUNtING
HEIGHT I?IM�N510N
NFPA IBC T;AMF 7.5.6,E CI%ANC�5 WOM IfAT5QWCF5
IfAf 50UPa
OWINA1?Y
TEMP.
INVlUllrr?IK
TEMP.
51a OF FIITpLACE
.56"
12"
FpONT OF FII t'I,AC.>
60'
36"
WOOD �I.P l% 5TOVE
4211
12"
K1TCIfN ma
18"
g"
WALL OVEN
16"
9"
HOr AIR FLM5
18"
9"
LNIN5ULAf P IfAf FLC5
IFS"
9"
LNINSULAtP HOf WA9P PIPE5
12"
6"
51a Of HOf Alp DIFFU15�Q
24"
12"
FQONT 0f HOT Alp VIFFU5FR
:6"
jail
HOT WAV KASP
6"
3"
ROOCF
6"
5"
50W-250W LICAW FIX11J1T
6"
V"
2501N-499W L&f FIXM
12"
6"
-rlEra
moo" X �
P.010 IN -
PA _c •. '
ry
CFAN 24hf'�
" VT ' A!STCR
3 H2O3 TILE
rA
oAin Q
-IL
4068
BI-TOLD STAIRCASE I1-1-IrM1NATION
1 W—"C>1" I -AND IN& ARD
O 5-�• TkL-AV'S 1't-k IkC-
3q" TAL_L- Wnl-1-
0
VN/ Wb_ GAFF
� r uBl�aHollNE -
1
L S1t� NOTES Mi ,
1 -SOLD S:
01 H217 °
O EL�W -
115S Leo&'emNu
I
THRE-Er
CARPET
III
i ate_
O O
-t-
i�
MASTER
off
M
PET
H2O5
C ' '
1 '
H2O4
III I-
1 '
I, I-U I H2O6C. I
INS 4 W-
A
_ A '
O p
0 1n O imma
WHOLE
lmliii 20I - I L ,AUN17f2Y Hfxa-,L
-1
° � � VINYL 0I„1
SS8421-18 u ��-VT
H215 �112100
• car .2x SnUr"A
— — a --
-j C
d Q�068
Q E3I-SOLD
ego
"
H212 H213 -
' BONUS '
ROOM s' 2.. PE 'ROOM
'. AFZPET U
=ARPE F
vj
3 H2O9
NJ
H211 H210
I I
UPPER FLOOR PLAN
SEE GENERAL NOTES
SCALE: 1 /4" = 1'-0"
FIRE SPRINKLER
RESIDENTIAL FIRE PROTECTION
-----------------------------------------------
PH 2O6-660-7442
EMAIL: Brent.nwcp@outlook.com
SPRINKLER INFORMATION
# OF HEADS ON THIS SHEET: 27
STATIC PRESSURE 95
t�
J
Z
ti
m
=
J
Z
W
Qa
00
Q
s
�
C
V
N
�
'>
�
Z
M51CAN ONLY 5TAMP
WASHINGTON STATE �
■ CERTIFICATE OF COMPETENCY ■
FIRE PROTECTION SPRINKLER SYSTEMS
i Brent Allen Besancon i
2409-0521-A I evel 1 ;
• NW Custom Plumbing, LLC �■
NViCUS''91 RN-1 0;
i■
EXPIRES •
Signature 12/31/26 1
IN5TALLIN6 CONTI?ZA rGV 5TAMr
WASHINGTON STATE �
■ CERTIFICATE OF COMPETENCY ■
FIRE PROTECTION SPRINKLER SYSTEMS
Brent Allen Besancon i
2409-0521-A Level ;
NW Custom Plumbing, LLC
pNWC�USP79I Rtvl o�
EXPIRES ■
Signature 12/31/26
�a
J
a.
Cl)
s
0
N
Q
Z
Q
Q
N
Q
Q
�
N
�
W
Q
TOM
DATE:
PERMIT:
REVISION:
PROJECT # 2401-10429EDMONDS
COMPANY: NW CUSTOM PLUMBING
LLC.
CONTACT: BRENT BESANCON
CONTACT #: 206-660-7442
SCALE 114=1'0"
DESIGNER: BRENT BESANCON