APPROVED FIR2024-0092+Fire_Alarm_Voltage_Calculations+9.25.2024_2.49.48_PM+4523599
GENERAL NOTES: DEVICE LEGEND ICON COUNT MAKE MODEL DESCRIPTION FACE 1 SILENT KNIGHT SK-5208 CONVENTIONAL ZONED FIRE ALARM CONTROL PANEL ST6 1 N/A N/A SHUNT TRIP BREAKER (PROVIDED AND INSTALLED BY EC) OO 1 SYSTEM SENSOR 2WTR-B CONVENTIONAL SMOKE DETECTOR W/ RELAY BASE O 1 SYSTEM SENSOR 5623 DUAL CIRCUIT HEAT DETECTOR (PROVIDED AND INSTALLED BY O 1 POTTER CR135-2CO-MP DUAL CIRCUIT HEAT DETECTOR (WEATHERPROOF) MR-101 1 FIRE-LITE MR-101 MULTIVOLTAGE RELAY (SHUNT POWER FAIL) 4 N/A N/A END OF LINE RESISTORS WIRE LEGEND ICON MAKE PART # DESCRIPTION ADI PRO RN-2005106 18/2 FPLP INITIATING DEVICE CIRCUIT (IDC) ADI PRO RN-2005106 18/2 FPLP NORMALLY CLOSED INC) RELAY CIRCUIT / N/A N/A 120VAC SHUNT TRIP CIRCUIT (PROVIDED AND INSTALLED BY EC) r cc _ ` r 1 NAGELs out to1 G��ego � 4 OIL1 r, purr f 71 'Qtl 14�� VICINITY MAP RISER DIAGRAM Emerald Place 400 Walnut St Edmonds, WA 98020 Z11 DEVICE SCHEDULE CRCUIT SETTINGS TOTALS Max circuit Length (R) Na Total Clrcut Length (Ft) 120 Circuit Wiring Properties 'Z 1812 FPLPIR (IDC) 18 AWG, 2 Oond. Sold Copper FPLPIR Analog Unshielded Distance measured using drawn segment lengths with 10 00 %addltlonal length calculated Device Label Part No. Building Floor Location Description Dist From Previous (Ft) Z11.1 EOL 4 7k CR135-2CO-MP EMERALD PLACE GARAGE ELEVATOR PIT 135 'F (57' C) FIXED TEMPERATURE, DUAL CIRCUIT 120 Z12 DEVICE SCHEDULE CRCUIT SETTINGS TOTALS Max ClRult Length (R) Na Total Circuit Length (Ft) 126 Circuit Wiring Properties 'Z 1812 FPLPIR (IDC) 18 AWG, 2 Cond- Sold Copper FPLPIR Analog Unshielded Distance measured using drawn segment lengths wth 10.00 %addltlonal length calculated Device Label Part No. Building Floor Location Description Dist. From Previous (Ft) MULTI -VOLTAGE RELAY ELEVATOR MACHINE Z12.1 EOL 4 7k MR-1011CR EMERALD PLACE GARAGE FOR SHUNT POWER FAIL 126 ROOM MONITORING Z13 DEVICE SCHEDULE CRCUIT SETTINGS TOTALS Max Clrcut Length (Ft) Na I Total Circuit Length (Ft) 126 Circuit Wiring Properties 'Z 18/2 FPLPIR (IDC) 18 AWG, 2 Cond Sold Copper FPLPIR Analog Unshielded Distance measured using drawn segment lengths with 10 00 %additional length calculated Device Label Part No. Building Floor Location Oescri 'on Dist From Previous Ft Z13.1 EOL 4 7k 2WTR-B EMERALD PLACE GARAGE ELEVATOR MACHINE ROOM SMOKE DETECTOR W/ RE LAY BASE 126 Z14 DEVICE SCHEDULE CRCUIT SETTINGS TOTALS Max Clrcut Length (Ft) I Na Total Circuit Length (Ft) 126 Circuit Wiring Properties 'Z 1812 FPLP/R (IDC) 18 AWG, 2 Cond Sold Copper FPLP/R Analog Unshielded Distance measured using drawn segment lengths with 10 00 %addltlonal length calculated Device Label Part No. Buil6ng Floor Location Description Dist From Previous (Ft) ELEVATOR MACHINE DUAL CIRCUIT HEAT Z14.1 EOL 4 7k 5623 EMERALD PLACE GARAGE ROOM DETECTOR FOR 126 ELEVATOR SHUNT TRIP STBJ NEW CKT TO ELEVATOR CONTROLLER FOR FLASHING HAT LIGHT Approved DFM chrCs Fuyt South County Fire Date: 10/07/2024 10-07-2024 RESUB 1 PLAN REVIEW NOTE: APPROVED DFM BURT 120VAC SHUNT POWER FAIL (BY OTHERS SYSTEM INPUTS 1) FIRE ALARM SYSTEM IS EXISTING. 2) ELEVATOR RECALLS ARE EXISTING. 3) ELEVATOR MACHINE ROOM HEAT AND SHUNT TRIP ARE EXISTING. A. EXISTING HEAT DETECTOR INPUT ZONE IS NEW. 4) ADDITION OF A SILENT KNIGHT 5217 INPUT ZONE EXPANDER TO THE EXISTING FIRE ALARM SYSTEM IS REQUIRED ACCOMODATE ADDED DEVICES. 5) ELEVATOR HOISTWAY PRESSURIZATION FAN IS EXISTING AND IS TRIGGERED OFF A GENERAL ALARM. A. EXISTING HOISTWAY PRESSURIZATION FAN HAS ONLY 1 SPEED. 6) PRIMARY AND ALTERNATE RECALLS AND FIREMAN'S HAT LIGHT ARE EXISTING. 7) INSTALLING A SYSTEM SENSOR 2WTR-B SMOKE DETECTOR IN THE ELEVATOR MACHINE ROOM (EMR). RELAY BASE FOR SMOKE DETECTOR WILL INITIATE FLASHING HAT LIGHT. 8) INSTALLING (1) POTTER 135 DEGREE RoR/FIXED TEMP DUAL CIRCUIT HEAT DETECTOR IN THE ELEVATOR PIT FOR HOISTWAY INITIATION AND FLASHING HAT LIGHT. 9) THE CIRCUIT FOR FLASHING HAT LIGHT WILL RUN THROUGH BOTH THE EMR SMOKE DETECTOR W/ RELAY BASE AND THE ELEVATOR PIT HEAT DETECTOR. EITHER DEVICE WILL TRIGGER FLASHING HAT AT THE ELEVATOR CONTROLLER. SHEET INDEX: FA 1.0 COVER SHEET FA1.1 FIRE ALARM PLAN GARAGE LEVEL TOP OF DETECTOR NOT AL I OWF D IN C',ORNF R N WAL. DETECTOR r ACCEPTABLE HERE 1 46' 1 FIRE ALARM SYSTEM OPERATIONAL MATRIX REQUIRED FIRE SAFETY CONTROL NOTIFICATION CONTROL UNIT ANNUNCIATION MOUNTING DETAILS n a COIL ING Box FIRE ALARM SMOKE DETECTOR h IHt ALAHM *rOHN'S I HOBS RECESSED DEVICE BOX WER MANUFACTURER'S REOUtrREMENTS) FIRE ALARM MANUAL RILL STATION AND -OR F RE ALARM ANNUNCIATOR RECESSED DEVICE BOX NOTES 1 CEILING MOUNTED DETECTOR DEVICES < SHALL BE LOCATED NOT LESS THAN 4• FROM A SIDE WALL tv++ 2 WALL MOUNTED DETECTOR DEVICES SHALL BE LOCATED BETWEEN 4' LL AND 12• FROM THE CEILING SYSTEM OUTPUTS e SRO aS� Q` y� f �� � �� �� qV� J`�� \�Q-> �� Ica O�Q ���Q �O`J O�py �h4° �pQ, �P �h JQ �� �. �O r1 ��V �`� ``h �° ,QO 'G) hS 14.° \��`� 14, �S �' �.° \��4 Q SC.� QSQJ °J�� �OQ�' �OQ �.P� C°`S 11 10 A B C D E F G H 1 1 K L M N O P O G CEILING BOX FIRE ALARM HORNISTROSE CEILING DETECTOR ACCEPTABLE HERE 1 MANUAL PULL STATIONS (EXISTING) X X X X X X 1 2 COMMON AREA SMOKE DETECTORS (EXISTING) X X X X X X 2 3 GARAGE FLOOR ELEVATOR LOBBY SMOKE DETECTOR (EXISTING) X X X X X X X X 3 4 1ST FLOOR ELEVATOR LOBBY SMOKE DETECTOR (EXISTING) X X X X X X X X 4 S 2ND FLOOR ELEVATOR LOBBY SMOKE DETECTOR (EXISTING) X X X X X X X X S 6 3RD FLOOR ELEVATOR LOBBY SMOKE DETECTOR (EXISTING) X X X X X X X X 6 7 ELEVATOR PIT HEAT DETECTOR X X X X X X X X 7 7 ELEVATOR MACHINE ROOM HEAT DETECTOR (EXISTING) X X X X X X X 7 8 ELEVATOR SHUNT TRIP POWER FAIL (MR-101) X X X X X 8 9 ELEVATOR MACHINE ROOM SMOKE DETECTOR X X X X X X X X 9 10 SPRINKLER WATERFLOW (EXISTING) X X X X X X 10 11 SPRINKLER TAMPER (EXISTING) X X X X 11 12 FIRE ALARM AC POWER FAILURE X X X X 12 13 FIRE ALARM SYSTEM LOW BATTERY X X X X 13 14 FIRE ALARM OPEN CIRCUIT X X X X 14 15 FIRE ALARM GROUND FAULT X X X X 15 16 16 �0000©oo©oo©o©©000 INI:Y�IYZ�IIII'j►� RECEIVED Sep 27 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SeaCom FIRE & SECURITY 3014 Hoyt Ave. Everett, WA 9M1 P:425.31Z8259 F:425.317-8261 =.cOwacom.com m Kory Mehl NICET FAS III #160751 , a a a w a 0 z 0 to z > O w O a Cn to w 0 JE O 71- 0) o _ II - 0 U cn `m E z U � O a` O N O N CN Y Y Y � m o> N 3 0 Q 0 o Q N 0 a+ O O CD CN = Q00 rn 5, >Q o M a) _ w to U O 0 V O 04 O rn 1n ry iv vi O L O O p O L Q o E -t E Co LU LU m ILL(1) FA 1.0 01 =1 �I ICI ICON COUNT MAKE MODEL DESCRIPTION FACP i SILENT KNIGHT SK-5208 CONVENTIONAL ZONED FIRE ALARM CONTROL PANEL ST6 i N/A N/A SHUNT TRIP BREAKER (PROVIDED AND INSTALLED BY EC) OO 1 SYSTEM SENSOR 2WTR-B CONVENTIONAL SMOKE DETECTOR W/RELAY BASE O i SYSTEM SENSOR 5623 DUAL CIRCUIT HEAT DETECTOR (PROVIDED AND INSTALLED BY OO 1 POTTER CR135-2C0-MP DUAL CIRCUIT HEAT DETECTOR (WEATHERPROOF) MR-101 i POTTER MR-101 MULTIVOLTAGE RELAY (SHUNT POWER FAIL) � 4 N/A N/A END OF LINE RESISTORS SeaCom FIRE & SECURITY 3014 Hoyt Ave. Everett, WA 98201 P: 425.317.8259 F: 425.317-8261 vlww.owl-acom.com m A K0ry Mehl NICET FAS III #160751 9 10 � r 13 14 15 L J ELEVATOR MACHINE ROOM 8 ELEVATOR r 1 t � CONTROLLER L J MR-101 7 r UP 1 r•� 16 6 L J r� B J 5 ri LJ 17 CN 4 CD 18 3 mi r L J J J 19 2 20 CL U Q LL 1 OVERHEAD DOOR OVERHEAD DOOR C DEVICE LEGEND as N L o ocu U c c d Q c2 m m� o �_0 L2 D 116- G) oo Q2 E co W w i� ) WIRE LEGEND F I R2024-0092 EMERALD PLACE - GARAGE LEVEL - FIRE ALARM PLAN RECEIVED C SCALE: 1 /8" = 1' Sep 27 2024 FA 1.1 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 5 4 3 2 1 ICON MAKE PART # DESCRIPTION ADI PRO RN-2005106 18/2 FPLP INITIATING DEVICE CIRCUIT (IDC) ADI PRO RN-2005106 18/2 FPLP NORMALLY CLOSED (NC) RELAY CIRCUIT N/A N/A 120VAC SHUNT TRIP CIRCUIT (PROVIDED AND INSTALLED BY EC) LJ J 25 24 26 23 � LJ 27 22 28 21 a a 0 z 0 `n w z � a U U W E z N O � 0) � o � II - oo U � s� E z U � O d O O o � N Y Y Y >, � T m 0) � -O 0) C � � 3 > 0 � 0 0 Q N O Or O � coil � Qrn � �Q o � M � _ W V O