Loading...
APPROVED FIR2024-0013+Fire_Alarm_Plan+2.9.2024_4.22.17_PM+4052372a cu 0 L� 0 Q l� 0 0 0 O a (14 O OL a 00 a a N 0 N 0 00 a 0 Approved DFM c,�Y%s Burt South County Fire Date: 02/22/2024 02-22-2023 PLAN REVIEW NOTES- APPROVED DFM BURT ELEC. ROOM 'I U O O O 110cd O O O �P�( O o E) (E) (E) rP ELEVATOR A ELEVATOR ?; (E) EQUIPMENT ROOM O O ARM — PRIMARY RECALL AIM wF A ARM — ALTERNATE RECALL At — FLASHING HAT A AIM - SHUNT AC MONITORING A AIM - SHUNT HEAT MONITORING A AIM - PIT HEAT 1 FIRE ALARM PLAN - GARAGE LEVEL SCALE: NONE RECEIVED Feb 12 2024 FIR2024-0013 CITYMONDS DEVELOPMENT SERVICES DEPARTMENT RTTMENT co m x v N N D co O m N N > cy) > IZI- Q N rl 0 n Z Li- 0 O 0 L1 KT coZm O=Li= a: Q J it E�11 U _ ti 7� - ry - ti — w DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951 L7 REFERENCE: 2018 IFC AND 2016 NFPA 72 z w o N O w 00 U z Q W z O w J z > w Q w > z L Q 0 v J MMcr Q 0 Q H JCNz Q C0 G w o LLI LL ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN GARAGE LEVEL DATE: FEBRUARY 8, 2024 PROJECT NO.: 24-003 SHEET: FA-1 a cu 0 L� 0 Q l� 0 O 0 O a N O N d 3 OL a 00 a a N 0 N 0 00 CJ a 0 STORAGE 212 STORAGE 211 COMMUNITY ROOM 2 STORAGE 01 2 UNIT 106 STORAGE 106 B 15cd :Y (E) 1 ��I Fl STORAGE 105 B BATHROOM SAUNA r- DH (E) E (E) STORAGE UNIT 102 UNIT 103 2 <-- -> 15cd (E) FACP UNIT 105 E E �(E) r-� (E) J(E) �n� (E) (E)�P B (E)rP 15cd 15cd `- 2 B ' ; �' B 2 2 ELEVATOR (E) (E) pH (E) DH� (E) TO FACP 11 ANN (E) (E) s C (E) UNIT 101 UNIT 104 L�JWp 75cd 1 FIRE ALARM PLAN - 1ST FLOOR SCALE: NONE RECEIVED Feb 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT co m x v N N D s= O m N N > Q N � � rl � � n Z = N mO�Ln O � L1 � co co � Q J � it E� H U - 7J '` J ti 1-- - r DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951 L7 REFERENCE: 2018 IFC AND 2016 NFPA 72 z W � N O W 00 U z Q w z O W J z � � � w � Q W > z 0 MM� Q O Q � N J z Q o W o � w ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN 1ST FLOOR DATE: FEBRUARY 8, 2024 PROJECT NO.: 24-003 SHEET: FA-2 a cu 0 L� 0 Q l� 0 O 0 O a N O N d 3 0- a 00 a a N 0 N 0 00 CJ a 0 m N N > Q N � � rl � � n Z = N mO�Ln O � L1 � co co � Q J � it E�11 U _ r� - flJ — DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951 L7 REFERENCE: 2018 IFC AND 2016 NFPA 72 z W � N O W 00 U z Q w z O W J z � � Q W > z Q 0 v J MM� Q O V J Q � N J z Q o w o � w L.L ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN 2ND FLOOR DATE: FEBRUARY 8, 2024 PROJECT NO.: 24-003 SHEET: UNIT 212 UNIT 213 (E) 7�,"k 2 UNIT 208 UNIT 209 (E)„� -> 15cd r-� B UNIT 211 HE) ,;, (E) (E) (E) U. (E) - (E) ��� (E) (E) LP B 15cd B B 15cd „ , ,�' 2 2 ELEVATOR 2 (E) (E)r (E) IDHI (E) ,DH, L_J L (E) % (E) a s UNIT 207 UNIT 210 1 FIRE ALARM PLAN - 2N D FLOOR SCALE: NONE RECEIVED Feb 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT co m x v N N D O FA-3 a cu 0 L� 0 Q l� 0 O 0 O a N O N d 3 OL a 00 a a N 0 N 0 00 CJ a 0 m N N > Q N � � rl � � n Z = N mO�Ln O � L1 � co co � Q J � it E�11 U _ r� - flJ — DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951 L7 REFERENCE: 2018 IFC AND 2016 NFPA 72 z w � N O W 00 U z Q w z O W J z � � Q W > z Q 0 v J MM� Q � N J z Q o w o � w ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN 3RD FLOOR DATE: FEBRUARY 8, 2024 PROJECT NO.: 24-003 SHEET: FA-4 UNIT 319 E (E) UNIT 315 UNIT 316 2 15cd r-� B (E)' P' (E) UNIT 318 H, _ ) E E (E) -J(E) (E) (E)�P B 2 15cd B ,� 7 B 15cd 2 2 ELEVATOR h (E) (E); H (E) DH- (E) L J (E) (E) a UNIT 314 UNIT 317 LL 1 FIRE ALARM PLAN - 3RD FLOOR SCALE: NONE RECEIVED Feb 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT co m x v N N D s= O 15cd 15cd 15cd L_ J L _JL_ 1 (E) (E) (E) (E) (E) (E) (E) (E) (E) I I I I I r-, r-� r -� r-� P~----yDH~----yDH~----yDH~----yDHI I L_J(E) `" (E) `" (E) `" (E) L_J(E) L_J(E) L_J(E) L_J(E) L_J(E) I I I THIRD FLOOR 15cd n n n r"� ----- .;H------/;H------/;H----y f. F----y < <=� L' L!=�(E) (E) (E) (E) I I I I I I I 15cd rye /, F------/:H------/;F-----�;F------/;H----y L!=�(E) n n n n (E) (E) (E) (E) I I I I I I I I I 15cd �"� f. F------- L!=�(E) I I I I I I I I I r-� !/� !/� /i ` /i ` /i ` r-� ----y P C C �: ----1 . C �/ P ~----yDH~----yDH~----yDH~ L_J(E) ," (E) ," (E) ," (E) L_J(E) L_J(E) ------------------------------- I I ---- yDHI L_J(E) L_J(E) LTJ(E) I SECOND FLOOR I I I I I I I I I I I I I I ----� H�----y H�----y H�----y H�--- I I L_J(E) L_J(E) L_J(E) L_J(E) 15cd I 15cd 75cd 15cd 15cd I n n �(E) �(E) F_____y`-_____- L_J(E) n n n n ;F_____yiF_____yiF____y �(E) �(E) �(E) �(E) ., f______- r-i I P F____y L,J(E) r-� ///��� rP� /ij (((��� P // / C C C ,C" - '-'(E) C L_J(E) '-'(E) j(E) / C C L J(E) (E) (E)(E)WP i I I (E) (E) I I I I ' I I FIRST FLOOR ---------------I I I I I I I I I I I C 110cd NAC 1 ----y e2 �E� ----1 ri, i---------a P r----y r-, ` P r----, �; ----T— PRIMARY RECALL (E) — ALTERNATE RECALL L_J WFI - FLASHING HAT JA — SHUNT AC MONITORING TO 120 VAC UNSWITCHED � � — SHUNT HEAT MONITORING DEDICATED CIRCUIT — PIT HEAT ,—, FACP FIRE ALARM ONE -LINE RISER DIAGRAM SCALE: NONE 3 cu 0 LL 0 Q l� 0 0 0 0 a (14 O N d 3 0- a 00 a a 0 0 N 0 ro N w a 0 SEQUENCE OF OPERATIONS N Lu J Q J Q Q z Q z cD O w z w 0 za in �o Z u 0 a > >c� z Q Q� O O O? J Q O O o Q Q Q z� N �< LU a �z aQ D N �J z c�I NV) �� 0V) U ULn w co> � Lu o� LLH �z JJ J Z Z� w m crz Lu Lu �p cc< >< zu z� c_7o Qu QQ Oz az aQ Qo �Q �° aV) �u V)u WATERFLOW DEVICE X X X X TAMPER DEVICE X X X BUILDING PULL STATION X X X X BUILDING SMOKE DETECTOR X X X X AC POWER LOSS X X X LOW BATTERY X X X DESIGNED AUDIBILITY LEVEL PER OCCUPANCY CLASSIFICATION GROUP A 70db GROUP B 70db GROUP E 60db GROUP F 95db GROUP M 55db GROUP R 50db GROUP S 45db BASEMENT EQUIPMENT LEGEND DEVICE SYMBOL QUANTITY PART NUMBER DESCRIPTION BACKBOX FACP 1 1 6700 SILENT KNIGHT FIRE ALARM CONTROL INCLUDED PANEL AN N-1 1 PHOTO—W SILENT KNIGHT SMOKE DETECTOR 4 SQUARE X 1-7/8" DEEP 0 25 PULLSA SILENT KNIGHT MANUAL PULL STATION SINGLE GANG ❑P 9 SWL SPECTRA ALERT WALL MOUNT 4 SQUARE X 1-7/8" DEEP STROBE Q 19 MHW SYSTEM SENSOR MINI NORM 4 SQUARE X 1-7/8" DEEP # 11 P2WL SPECTRA ALERT WALL MOUNT 4 SQUARE X 1-7/8" DEEP HORN STROBE WF 1 -- WATER -FLOW CONNECTION (•) PROVIDED BY OTHERS # 1 P2RK SPECTRA ALERT WEATHERPROOF 4 SQUARE X 1-7/8" DEEP wP HORN STROBE AIM 4 MONITOR SILENT KNIGHT ADDRESSABLE 4 SQUARE X 1-7/8" DEEP INPUT MODULE ARM 3 RELAY SILENT KNIGHT ADDRESSABLE 4 SQUARE X 1-7/8" DEEP RELAY MODULE INTELLINET RADIO COMMUNICATOR -- DH 13 -- DOOR HOLDER -- N PROVIDED AND INSTALLED BY OTHERS --------- EXISTING DEVICE TO REMAIN NEW OR EXISTING DEVICE RELOCATED # INDICATES CANDELA (E) INDICATES EXISTING C INDICATES CEILING MOUNT EOL^/,,- END OF LINE RESISTOR WIRE LEGEND TYPE DESCRIPTION A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS, AND BACK BOXES ARE TO BE PAINTED RED. 4. PULL STATIONS ARE TO BE MOUNTED AT 42" TO 48" ABOVE THE FLOOR. 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES, AND SPEAKER STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER. 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: A) 36" INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES 7. EXTERIOR HORN / STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING, AS HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. RECEIVED Feb 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT m N N > cy) > IZI- Q N rl 0 n Z Li- 0 O � L1 KT coZco c; a: Q J it H11 U _ 7. - ry — rL — DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951 L7 REFERENCE: 2018 IFC AND 2016 NFPA 72 z W o N O W 00 U z Q Lu z 0 W J z > ICI C� Q W > z L Q 0 v! Q 0 Q N J z Q O W o LLI LL ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM LEGENDS, NOTES AND RISER DIAGRAM DATE: FEBRUARY 8, 2024 PROJECT NO.: 24-003 SHEET: FA-5