FIR2024-0013+Fire_Alarm_Equipment_Specification_Sheets+2.9.2024_4.21.34_PM+4052365Honeywell ®SILENT* MGHT 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor' (SK) sensors and 50 SK modules or 50 Hochiki° (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - line POTS and IP communicator and optional cellular side -cars. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT° wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard - to -wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models. • Convenient field-upgradeable firmware • Integrated dual path I and POTs communications and optional cellular side -cars for reliable backup • 6860 annunciator with a 4 x 40 large display, and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. • Built-in USB interface for convenient and quick programming 6700 It supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL po�dule, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Built-in dual phone line and digital alarm communicator/ transmitter (DACT) for additional communication options • 125 software zones and 125 output groups for flexible design options 6700 Product Information SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. RI1][9flk%]:711[el:h&I • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. 6700 KEYPAD PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° autoprogramming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS),which is Windows° based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires Windows -based computer. ADDITIONAL INFORMATION Twisted -unshielded pairwire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS N FPA 13, N FPA 15, N FPA 16, N FPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services. • UL Listed: S2766 • CSFM 7165-0559:050 • FDNY COA# 6250 • Seismic (CA) (pending) ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860:4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860:4x20 LCD remote fire annunciator. 5860 is gray; 586OR is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 1350Ffixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T. Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T. Photoelectric smoke detector with thermal (135°F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B21OLP: 6" mounting base B501:4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounderbase B224RB: Relay base B224B1: Isolator base SO COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-616: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicatorforthe SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T. Wireless Multi -criteria photoelectric smoke detectorwith thermal detection (135°F fixed temperture) and B510W 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperture) and B51OW 4" base WSK-HEAT-ROR: Wireless heat, ROR (1351Ffixed temperture) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput- circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm° receiver atthe central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Two programmable circuits which can be compliance approvals and Weight' 15 lbs. ' programmed individually as: certifications, please visit www.silentknight.com. Color: Red NACs: 2.5A C 27.4VDC per circuit, power -limited (with a panel maximum current of 2.5A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 2.5A C 27.4VDC per the Windows Logo are Operating Temperature: 32°Fto 120°F (0°C to circuit, power -limited registered trademarksor trademarks of 49°C) Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) configuration for the SLC Silent Knight°, Honeywell' and SWIFT° are registered trademarks of Honeywell ELECTRICAL WIRING: See the product manual for wiring details International, Inc. 6700 Primary AC: 120 VAC C 60 Hz, 1.5ATotal Accessory Load: 2.5A C 27.4VDC power -limited This document is not Standby Current: 165mA S intended to be used for installation purposes. We Alarm Current: 310mA try to keep our product Battery Charging Capacity: 7 to 35AH information up -to Battery Size: 7AH max. allowed in control panel date and accurate. cannot coverall specific cabinet. Larger capacity batteries can be housed in applications oranticipate RBB accessory cabinet.. all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT06472 Honeywell 351607A11/17 800-328-0103 9 2017 Honeywell International Inc. Honeywell ®SILENT* MGHT SK-PHOTO-W Series Intelligent Plug -In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Serif plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES & BENEFITS • New modern profile for improved aesthetics • Stable communication technique with noise immunity • Low standby current • Two -wire SLC connection • Optional remote, single- gang LED accessory • Dual LED design provides 3601 viewing angle • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper - resistant feature • Sealed against back pressure • Expanded color options • SEMS screws for wiring of the separate base SK-PHOTO-W • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA72. System Smoke Detector Application Guide, documentA05-1003, is available at systemsensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. • When using relay or sounder bases, consultthe installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector, white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. II:YIMIIII III Id4:Y111-JeF9=9 13300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. Filets] *Pie7:I1 *I CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory,10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack. M02-04-01: Detectortest magnet. M02-09-00: Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for 3300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts) Humidity: 10% to 93% non -condensing Thermal Ratings: Fixed Temperature Set point: 1350F(570C) ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Operating Current @ 24VDC: 200µA (one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panelwith an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. U L listed: S6173 FM approved CSFM: 7272-0559:0523 Doc 3516341 Rev A 104/18 9 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.siLentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight°, System Sensor' and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. Honeywell SILENT' KNIGHT Honeywell RNIGHT LENT' SK-Pull-SA Addressable Pull Station Document 52151 156-3446-005 Description The SK-Pull-SA Addressable pull station is a non -coded, single-action manual pull station with a key -lock reset feature. It provides Silent Knight intelligent fire alarm control panels (FRCP) with one addressable alarm initiating input. The addressable module is housed inside the pull station. The SK-Pull-SA is compatible with all Silent Knight intelligent panels that use the Intelligent Device Protocol (IDP). Refer to the FACP Installation Manual to determine if the Intelligent Device Protocol is supported. The SK-Pull-SA meets the ADAAG controls and operating mechanisms guidelines (section 4.1.3 [13]), and the ADA requirement for a 5 lb. maximum pull force to activate the pull station. Operating instructions are molded into the pull station handle along with Braille text. Molded Terminal numbers are also present. Conforms to ANSI/UL Standard 38. Ratings Normal Operating Voltage: 24VDC. Average Operating Current (LED Flash): 375 µA. Maximum Operating Current (LED On): 5 mA. Temperature Range: 32°F - 120°F (0°C - 49°C). Relative Humidity Range: 10% - 93% non -condensing. Installation The SK-Pull-SA Addressable pull station can be surface mounted to a SB-I/O surface backbox or semi -flush mounted on a standard single -gang, double -gang or 4- (10.16 cm) square electrical box. The optional BG-TR trim ring can be used if the SK-Pull-SA is to be semi -flush mounted. Operation To activate the single-action pull station, simply pull down the handle. The word `ACTI- VATED' appears after the handle is pulled down. This will remain until the pull station is reset. The pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) switch which closes upon activation of the pull station. Resetting the Pull Station 1. Insert the key into the lock and rotate 1/4 turn counterclockwise. 2. Open the door until the handle returns to normal. 3. Close and lock the door. NOTE: Closing the door automatically resets the switch to the `Normal' position. Opening the door will not activate or deactivate the alarm switch. Wiring To Next Addressable From Device FACP + + SLC — — SLC 0 0 LLI 0 0 e©ee STRIPGAUGE J �(J o iLa ARNING! Do not loop wiring under any terminals. Break wire run to maintain IDC supervision. SK-Pull-SA Addressable Pull Station Document52151 156-3446-005 CAUTION! Do not detach the door of the pull station during installation. The door of the pull station cannot be reattached to the backplate after the backplate has already been installed onto an electrical box. CAUTION! Install the Silent Knight SK-Pull-SA addressablepull station in accordance with these instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be conducted in accordance with the appropriate NFPA standards. Failure to follow these directions may result in failure of the device to report an alarm condition. Silent Knight is not responsible for devices that have been improperly installed, tested or maintained. ADA Compliance For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 inches (121.92 cm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach allowed is 54 inches (137.16 cm). I56-3446-005 07-24 Setting the SK-Pull-SA Address The SK-Pull-SA Addressable pull station is factory preset with address `00.' Set the address for the pull station by turning the rotary address switches on the addressable module mounted inside the pull station. Only one device per address is allowed. Multiple modules may not be set to the same address on the Signaling Line Circuit. Once the address is set, record it in the space provided on the product ID label located inside the pull station. LED OPERATION Alarm: Steady RED Normal: Flash GREEN Note: LED is visible through L E D translucent handle. 0 ROTARY ADDRESS SWITCHES Honeywell r SILENT° IINIGHT 12 Clintonville Road Northford, CT 06472 203-484-7161 Fax: 203-484-7118 www.silentknight.com Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc. I56-3446-005 ©2017 Honeywell. 07-24 SILENT KNIGHT by Honeywell SK-Monitor Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Installation The SK-Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. Compatibility The SK-Monitor is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL 5820XL-EVS SK-Monitor Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Model SK-Monitor Intelligent Monitor Module TO NEXT DEVICE MICIN ITOR AN/ NUMBER Cf UL USrED CC#MCT (-1 MODULE C CLOSURE DIEV CE9 MAY BE USED. C MDT MIX � FIRE ALARM INTIATNG, 9LPERASORY, OR O 0 EEC UFUTY DEVICES ON THE SAYE MCOLLE. • _ O L n FIKM FRINEL OR PREVIOUS DEVICE CONNECT M-CULESTO LISTED OCMPATIELE CONTROL PANELS ONLY 47K EOL SIGNAL LINE CIRCUIT i 9LCj RESISTOR 32 Voc MAX ELAJ7K TNISTED PAIR Q I9 FECOMENCED INITIATING DEVICE CSCUR .1DC, - NFPA STYLE B P'DAER UMTED:46CVA MAX. A 11 VD: MAX INSTALLCCoNlACT CLOSURE DEVICES PER ALLWIRIND EI-KMN 19 9UPER'.16ED AND POWER LFAMED MANUF4CTUFSTS IRSTALLATICN NSTRIUCTION9, 2-Wire Initiating Circuit Configuration, NFPA Style B TO NEXT Od00�, FROM PANEL OR DEVICE C'._ PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED. DO NOT MIX ^ A CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING, SUPERVISORY, OR r Q Qo \ , NOTIFIER CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. v • v n AIM (d T \ SIGNAL LINE CIRCUIT (SLC) EOL RESISTOR IS o 03VDC MAX. INTERNAL AT SHIELDED -TWISTED ISCOMEN PAIR O IS RECOMENDED TERMINALS 8 & 9 INSTALL CONTACT CLOSURE DEVICES PER ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED MANUFACTURER'S INSTALLATION INSTRUCTIONS. 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: 400 pA max @ 24 VDC (one communication every 5 sec with 47K EOL) 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1 K) 5.5 mA (with LED latched on) LED Current: 5.5 mA (with LED latched on)End-of-Line Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Ordering Information SK-Monitor Monitoring Module Resistance: 47K Q Accessories Initiating Device Circuit Wiring Resistance: 1,500 0 max SMB500 SLC Loop Resistance: 40 0 max. 4" Square Surface Mount Electrical Box SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 8200-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350131 Rev D © 2013 Honeywell International Inc. SILENT KNIGHT by Honeywell SK-Relay Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two -wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-Relay, the relay is triggered by the FACP. Features • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible —can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed SK-Relay Installation The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight Compatibility The SK-Relay is compatible with the following IntelliKnight FACP's: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK-Relay Intelligent Relay Module To Next Device 0o o� Relay Common 2 Normally Closed 2 1B s o s 3� Normally Open 2 '„;• 2 Relay Common 1 s '•' $ Normally Closed 1 � s :� 4 If Any Wiring to Terminals 3 — 9 is Not Power Limited, the CB500 Barrier is Required. The CB500 Includes a Non -Power Limited Label, Which Must Be Placed Over the Power Limited Terminal Information on the Name Plate Label. — From Compatible FACP + or Previous Device Module Does Not Supervise Normally Open 1 Controlled Circuits Specifications Physical Height: 4.65" Width: 4.25" Depth: 1.1" Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 230 pA (LED flashing) direct poll 255 pA (LED flashing) group poll Wiring the SK-Relay Module End -of -Line Resistance: not used Standby Current: 300 pA max @ 24 VDC (one communication every 5 sec with LED enabled) LED Current: 5.5 mA (with LED latched on) SLC Loop Resistance: 400 max. Relay Contact Ratings 3.OA @ 30 VDC resistive 0.9A @ 110 VDC resistive 0.9A @ 125 VAC resistive 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) SILENT This document is not intended to be used for installation purposes. We try KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350127 Rev D © 2013 Honeywell International Inc. SYSTEM SENSOR- ' I I I I I I I' FIIII F Indoor Selectable- R� - L R r �, _ Output Horns, E ��•�-•'4 E Strobes, and Horn Strobes for , Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut r� installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listings SIGNALING @ F M LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 1 7/a-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit"" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120OF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 DC Input MS), 2-Wire Horn Strobe, Candela I 8—M Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data morn ana Switch Position morn 5trObe. .: Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9� Coded High 85 90 90 10' 3.1 KHz Coded High 84 89 89 . Settings 9 and 10 are not available on the 2-wire horn strobes L-Series Dimensions 1.91 3.46 1.25 0 0 0000000000aoa aoaoa000nonon 5.27 Compact Strobe / Horn Strobe 4.70 1.91 1.25 5.67 0 Strobe / Horn Strobe L-Series Ordering Information 5 3.46 Compact Horn 1.25 Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGWL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT' marking on cover SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2017System Sensor. SENSOR® Phone: 800 SENSOR2 •Fax: 630 377 6495 Product specroduionssubject tochange wtheltesnotice version of for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS86503.03/17 6,�� SYSTEM � SENSOR - Mini -Horns The SpectrAlefV Advance series of mini -horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non -temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-AlertTM sounders • Listing for ceiling or wall mounting Agency Listings o � � U F M C . T �, .O� ER i LISTEDAPPROVED S4011 3028007 CS1099 7135-1653:196 The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non -temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. SpectrAlere Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini -horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync•Circuit"" Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.61 x 2.9W x .451D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single -gang back box (23/4-deep) Flush: Standard 4-x 4""back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output .: Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 16-33 VFWR VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High temporal 72 71 75 74 80 79 4 Non- Low temporal Sounder Current Draw (mA RMS) 70 69 73 72 78 77 Switch Position Sound Pattern 8-17.5 Volts Volume DC FWR 16-33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non -temporal High 22 17 29 25 4 Non -temporal Low 17 13 21 19 Ordering Information DescriptionPart No. MHR Mini -Horn, Red MHW Mini -Horn, White SYSTEM SENSOR" 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©t to c System Sensor. Product specifications subject to change without notice. Visit systemsensoccom or current product information,Dihiatestversionof his data sheet. AVDS01 S0150000 • 33/12 6,�� SYSTEM � SENSOR - Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O '> F M MEA 7300-1653:187 (outdoor strobes) LISTED roved 7125-1653:188 (horn strobes, a S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 30281 MEA452-05-E 7135-1653:189 (horns, chimes) f o m S y s t e rn S e n s o r SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40oF to 151 °F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL .. . 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 it 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8-175 16--33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 wc Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diaqrams 2.5" Wall -Mount Horn Strobes 'a erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ©o12 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,Diheiatestversionof his data sheet. AVDS01 S0120101 • 3/12