Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2024-0010+Fire_Alarm_Equipment_Specification_Sheets+2.2.2024_12.23.19_PM+4037005
40- mW SERIES Addressable Photoelectric Smoke Detectors RECEIVED FIR2024-0010 Feb 02 2024 CITY OF EDMONDS The Silent Knight° SK-PHOTO-W Series °E"E OPMENT EPARTMENRVICES feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be setwith rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 1350F (5700 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detectorfor use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink every time the unit is polled • 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases Honeywell SILENT' KNIGHT INSTALLATION The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet I56-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control paneland reports its type and the status. If it receives a test command from the panel (or a local magnettest), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: "-IV" suffix indicates ivory color. SK-PHOTO-W: White, low -profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 135°F (57°C) fixed -temperature thermal device SK-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of 3300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B20OS-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B21OLP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00:Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351634:B • 7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Sensitivity: - UL Applications: 0.5% to 4.0% per foot obscuration. - ULC Applications: 0.5%to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see S K-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W: 32°F to 122°F (0°C to 50°C) • SK-PHOTO-T-W:320Fto1000F(00Cto 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 1580F (-20°C to 70°C) UL/ULC Listed Velocity Range:0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity:10% — 93% non - condensing Thermal ratings: fixed -temperature set point 1350F (570C), rate -of -rise detection 15OF (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA C 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.silentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications referto N FPA 72. A System Smoke Detector Application Guide, document A05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. • UL Listed: S6173 • FM Approved • CSFM:7272-0559:0512 351634 1 B 1 07/19 ©2019 Honeywell International Inc. Honeywell SILENT' WGHT SILENT KNIGHT by Honeywell SK-Pull-SA and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. IN SLC OUT comp N Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 32° — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Accessories BG-TR Optional trim ring. SB-1/0 Surface backbox 3 SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350135 Rev B © 2012 Honeywell International Inc. Honeywell QGamewell �^ Accessories Fire Alarm Documents (FAD) Cabinet Fire Alarm Storage Cabinet General The Gamewell-FCI Fire Alarm Documents Cabinet (FAD) is the perfect solution to meet the demanding code standards required today. Gamewell-FCI's primary goal is to manufacture code compliant solutions and this product allows you to do just that. This cabinet is the answer to comply with the N FPA 72 2007, Section 6.2.2.1 requirements which states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit. The Fire Alarm Documents cabinet may be used as a storage box for both printed and digital documentation, enabling you to store the system's test and certified inspection documents, service records, manuals and AS built drawings. This cabinet is constructed of durable 16 gauge steelwith a solid piano hinge and key lock. The cabinet includes a 4GB USB memory flash drive interface. Using a standard USB B connector, the USB flash drive interface allows you to use any standard USB printer cable to upload or download information. This feature allows you to store the fire alarm software in one secure place, so that the Technician can easily access the software and service the system. Fire Alarm Documents Cabinet The Fire Document Box (FDB) interior is designed to contain critical manuals and documents. It is constructed with a durable steel retainer. The FDB has two key ring hooks to hold system keys, and a frame to insert Authorized personnel business cards. In the inner door, you can add the Legend Sheet to record property, system, service, code and AHJ certification information, as well as required documentation. (See Figure 2). Ordering Information: GW-FAD: Fire Alarm Storage Cabinet, Red FEATURES & BENEFITS • Installed with a 4 gigabyte digital flash drive interface with USB B connector • Overall Dimensions 12"Width x 13" Height x 21/4" Depth (30.48 W x 33.02 H x 5.71 D cm) • Offers two, key ring hooks to hold the system keys • Contains a frame plate to insert Authorized Personnel business cards • Constructed with 16 gauge steel box and cover for added security with a solid stainless steel hinge • Coated with a durable, baked -on finish (other colors available) • Built with a stainless steel piano hinge with standard 3/4"cat 30 key lock (other lock assemblies available) • Includes a Legend Sheet to record passwords and system information • Imprinted with white indelible ink, 1" high lettering labeled, "FIRE ALARM DOCUMENTS" Figure 1 shows the interior enclosure of the Fire Alarm Documents cabinet. Interface requires 1N B-B Connector Hooks Card Holder Legend sheet used to store system information including the following: - Contacts Sign -off Maintenance Test information Alternate locations of additional records Figure 1 Fire Alarm Documents Cabinet Figure 2 shows the Legend Sheet attached to the inner door of the Fire Alarm Document Cabinet (See Figure 2). Property Information Minimum Required Documentation Name of Property: 1 Written narrative providing intent and system description. Address: FN/A FEnclosed or Alt. Location: 2 Riser diagram Description of Property: Occupancy Type: FN/A F Enclosed or Alt. Location: Certification and Approvals 3 Floor plan layout showing location of all devices and control equipment. 16.1 System Installation Contractor: F-]N/A Enclosed or Alt. Location: This system, as specified herein, has been installed and 4 Sequence of operation in either an input/ output matrix or narrative form. tested according to all NFPA Standards cited therein. FIN/A FlEnclosed or Alt. Location: Signed: 5 Equipment technical data sheets. FIN/A FlEnclosed or Alt. Location: Printed Name: Date: / / 6 Manufacturers published instructions, including operation and maintenance instruction. Organization: FIN/A FlEnclosed or Alt. Location: Title: 7 Battery calculations (where batteries are provided). FIN/A FlEnclosed or Alt. Location: 8 Voltage drop calculations for notification appliance circuits. Phone: 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this with ❑ N/A ❑ Enclosed or Alt. Location: system and find it to be installed and operating properly in 9 Completed record of inspection and testing in accordance with 7.6.6 and 7.8.2. accordance with its approved plans and specifications, F-1N/A FlEnclosed or Alt. Location: its approved sequence of operations, and with all NFPA 10 Completed record of completion in accordance with 7.5.6 and 7.8.2. standards cited herein. F1N/A F1 Enclosed or Alt. Location: Signed: 11 Copy of site specific software, where applicable. FIN/A FlEnclosed or Alt. Location: Printed Name: Date: / / 12 Record (as -built) drawings. Organization: FIN/A FlEnclosed or Alt. Location: Title: 13 Periodic inspection, testing, and maintenance documentation in accordance with Section 7.6. F1N/A FlEnclosed or Alt. Location: Phone: Equipment Information: ID No. 1: 14 Records, record retention, and record maintenance in accordance with 7.7. FIN/A FlEnclosed or Alt. Location: Serial: Access Code: ID No. 2: Signed: Date: / / Serial: Access Code: Figure 2 Legend Sheet Fire Alarm Documents (FAD) Cabinet Technical Specifications SYSTEMS FAD: Fire Alarm Documents Cabinet Dimensions: l2° W x 13" H x 21/4" D (30.48 W x 33.02 H x 5.71 D cm) Door Keylock: Barrel lock and piano hinge Dimensions: 3/4" barrel lock and 12" (30.48 cm) piano hinge FAD Cabinet: UL° Listed, constructed of 18 gauge cold rolled steel Cabinet Finish: Red powder coat epoxy finish Cabinet Cover Label: Silkscreen imprinted with white indelible ink,1" high lettering labeled, "FIRE ALARM DOCUMENTS" Cabinet Keylock: Keylocked with 3/4" barrel lock and 12" (30.48 cm) width stainless steel piano hinge Cabinet Backbox: The backbox includes a 4-hole knockout mounting pattern. Cabinet Frame Plate: insert frame plate accommodates and protects standard 81/2 x 11 manuals and document records. Cabinet Inner Door Label: Legend Sheet attached to the inner door frame for system required documentation, key contacts and code information. Cabinet Flash Drive Interface:4 Gigabyte (minimum) digital flash memory drive with a standard USB B connector (used to upload and download information) is securely assembled to the interior cabinet. The drive is restricted to Authorized personnel with permission to use secure hardware devices to access the records. Cabinet Key Holder: Two key ring holders and a pre - assembled frame plate to insert Authorized Personnel business cards. For more information Learn more about Gamewell-FCI's Fire Alarm Documents (FAD) Cabinet and other products available byvisiting www.Gamewell- FCl.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The Fire Alarm Documents (FAD) Cabinet is designed to certifications, please visit: comply with the following standard: http://www.gamewell- UL Standard: S2580 fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules Gamewell-FCI° is a registered specified in this document. In some cases, certain trademark of Honeywell modules or applications may not be listed by certain International Inc. approval agencies, or listing may be in process. Consult factory for latest listing status. Space Age Electronics, Inc. is a ©copyright. UL: S2580, Vol. 3 CSFM: 7300-0553-0110 UL° is a registered trademark NFPA: 72 2007 of Underwriter's Laboratories Inc. NEMA ISO 9001 Certification This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications aresubjectto change without notice. 1OS/18 @2Honeywell ©2018Hone Honeywee ll International Inc. ..,:.....:.:...:..:.:..:.:..:..... MODULAR SECURITY ACCESSORIES RJ31X JACK AND CORD SETS Part # iEl.'UL UJUC KJ-j1A modular JacKs. tJoia piatea conauctor (917UL) Pins. Shorting bar 1, 4, 5 and 8 UL Listed. Packaged (+91628) with matching color coded cord. 26 AWG 2ft. 8P8C to spade lugs with strain relief. (Color Header card for Display) SETUL50 Same as above with 50 microns of gold plating on (917UL50) conductor pins. Packaged with matching color coded (+91.628) cord. 26 AWG 2ft. 8P8C with header SET (Standard) 91.7 + 91628 packaged with header SETULR2 917UL RJ31 X Jack UL Listed. Packaged with 26 AWG (917UL) 8P8C nod to 8P8C nod straight wired cord. With (+804R2) header SET14 Standard 91.7 RJ31X Jack packaged with a 8P4C (917) modular cord to spade lugs 1 ft. strain relief. With (+91614) header ( Packaged ) SETULNH i SETUL50NH i SETNH -3- MODULAR SECURITY ACCESSORIES USOC RJ31X JACKS 8P8C Gold plated conductor pins. Individually bagged with C mounting screw and doubled - sided stick tape. Made with 94VO flame retardant plastic. Shorting bar on 1, 4, 5, and 8 Ideal for security installations. UL Listed. Color Ivory. Part # 917 Standard- RJ31X Jack 917UL50 8P8C RJ3IX UL Jack with 50 microns of gold 9174UL50 8P4C RJ31X UL Jack with 50 microns of gold 9174A Combo 8P8C RJ31X Jack with RJI 16P4C 917B 8P8C RJ3IX Jack 3-3/4" x 2-1/4" 916 - RJ31X CORD 8 CONDUCTOR 8P8C Round 26 AWG silver satin, plug to spade lugs. Color coded to match RJ31X Jack. Available in 1, 2, 4, and 7 ft. lengths. 191618 -Ift. RJ31 X cord Ift. 8 conductor 91648 -4ft. RJ31X cord 4ft. 8 conductor 91678 -7ft. RJ31X cord 7ft. 8 conductor 1916 — RJ31X CORD 4 CONDUCTOR Modular 81`4C flat 28 AWG silver satin, plug to spade lugs. Color coded to match RJ3IX Jack. Available in 1,2, and 7ft lengths. 91614 -1 ft. RJ31X cord Ift. 4 conductor 91624 -2ft. RJ3IX cord 2ft. 4 conductor 91674 -7ft. RJ31X cord 7ft. 4 conductor OL CSA Available 6820 Intelligent Fire Alarm Control Panel with Communicator The 6820 features an expandable SLC circuit, six Flexput circuits, dual -line DACT, powerful software features, and connectivity for up to 17 panels. The 6820 is the latest intelligent addressable FACP (Fire Alarm Control Panels) from Silent Knight and is a direct replacement for the 5820XL FACP. The FACP has one built-in SLC (signaling line circuit), which can support 159 System Sensor' SK detectors and 159 SK modules, or 127 Hochiki° SD protocol devices. Additional SLC loops can be added for a maximum of 1110 (SK) or 635 (SD) points per panel. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The I P communicator's internet monitoring capability sends alarm signals overthe Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication overthe public switched telephone line. Optional cellular reporting is available. The 6820 has six onboard Flexput' circuits that can be configured as notification outputs or auxiliary power. The 6820 also has a form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre -trouble maintenance alert, a built-in sensor test to complywith NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. FEATURES AND BENEFITS • Complies with UL 86410th Edition and UL 2572 2nd Edition Standards • Expandable SLC loops to 1110 (SK) or 635 (SD) point capacity • Six Flexput circuits for NAC outputs or auxiliary power • Selectable strobe synchronization for Amseco°, System Sensor, Wheelock', and Gentex° devices • Built-in DACT with IP and optional cellular reporting • Built-in USB interface for quick and easy programming • JumpStart° auto programming reduces installation time • 999 software zones and 999 output groups for flexible design options • 23 preset notification cadence patterns (including ANSI° 3.41) • Allows up to 24 SBUS devices • Four programmable function keys • Two programmable relays and one fixed trouble relay • Compatible with SWIFT° wireless devices • Convenient field-upgradeablefirmware • Common Communications Linkfor upto 17 sites • Network card allows copper network connection with a multi -mode or single - mode fiber connection • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Available in a red or black cabinet • Surface mounting or flush mounting cabinet Honeywell ®SILENT' IQVIGHT USERINTERFACE LED INDICATORS • General Alarm (Red) • Supervisory (Yellow) • System Trouble (Yellow) • System Silenced (Yellow • System Power (Green) KEYPAD • 12-key numeric pad • Acknowledge • Alarm Silence • System Reset • Drill • F1-F4 Programmable Function Keys PROGRAMMING The 6820 system offers several options to simplify and expedite programming. JumpStart° auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on -site access to current system programming. System programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6820: Addressable fire alarm control panel, red COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 586OR: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators can display up to 30 LEDs (15 red and 15 yellow) 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED 1/0 module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: SeriaVParallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SKand SD devices cannot be mixed in the same fire alarm system. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1350F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1900F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10:10- input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector. white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PHOTO-T: Photoelectric smoke detectorwith fixed thermal heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detectorwith fixed thermal heat (1350F), white SK-PTIR-W: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module SK BASES B21OLP: 6" mounting base B501: 4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounder base B224RB: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same fire alarm system. SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR Page 2 of 4 — 351610:C • 2/16/2022 SD505-DUCT: Addressable Duct Smoke Detector SD505-DUCTR: Addressable Duct Detector housing with relay base SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C) SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-H EAT: Wireless, fixed heat detector (135°F) with B501W base WSK-HEAT-ROR: Wireless rate -of -rise heat detector and B501W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-RL, WAV-WL, WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFTTools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.silentknight.com SYSTEM EXPANDERS 6815: SLC Expander for SK devices 5815XL: SLC expander for SD devices 5895XL: 6A power supply with six Flexput circuits and two Form C relays 5496: 6 amp NAC power expander with four power -limited output circuits OPTIONAL COMMUNICATORS CELL-CAB-SK: Cellular communicator, metal enclosure with lock and key CELL -MOD: Cellular communicator, plastic enclosure IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorALARM° receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode transmitter and receiver SK-FSL: Fiber -Optic Single Mode transmitter and receiver RBB: Remote Battery Box accessory cabinet, holds batteries up to 35AH SK-SCK: Seismic compliance kit used to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° -based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel's USB port using a flash drive. Requires a PC running Microsoft' Windows°. Page 3 of 4 — 351610:C • 2/16/2022 6820 TECHNICAL SPECIFICATIONS SYSTEM CAPACITY • Intelligent Signaling Line Circuits:1 (expandable) • Addressable device capacity:1110 (SK) or 635 (SD) • Programmable software zones: 999 • Output groups: 999 • Output circuits: 6 (expandable) • SBUS devices: 24 (16 annunciators, 8 LED modules) ELECTRICAL • AC Power:120VAC, 60Hz, 3.3A • Standby Current:190 mA • Alarm Current: 250 mA • Flexput Circuits: Terminal block provides connections for(six Class B orthree Class A) NACs or auxiliary power. Power -limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End -of -line resistor:4.7k ohm,'/2 watt for Class B NACs • Communication Loop: Supervised and power -limited, Class A or Class B, 32VDC, 150mA • Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A C 27.4VDC (resistive), Form C • Battery: Cabinet holds maximum of two 18 AH batteries • Battery Charger Capacity: 7-35 AH PHYSICAL Dimensions:16.4" W x 26.4" H x 4.1" D (41.66cm W x 67.06cm H x 10.41cm D) Weight:32lbs. (14.5 kg.) Color: Red Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.silentknight.com TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 49°C (32-1200F) and at a relative humidity 93%± 2% RH (non - condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 270C/60 — 80°F. NFPA STANDARDS The 6820 complies with the following standards and codes: NFPA 72 NFPA 13 NFPA 15 NFPA 16 NFPA 70 UL86410th Edition AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-0559:0500 FDNY COA# 6249 FM Approved Seismic: (CA) VMA-45894-05C 351610 1 C 1 04-22 ©2022 Honeywell International Inc. Honeywell ®SILENT' KNIGHT 'TAT-W SERIES Addressable Heat Detectors The Silent Knight"' SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The series includes a 1350F/571C fixed -temperature, rate -of -rise, and a 1801F/881C fixed high -temperature detectors and are direct replacements for the SK-HEAT Series heat detectors. The point ID address, set using rotary decimal switches, provide specific detector Locations. These thermal detectors provide effective, intelligent property protection in a variety of applications. • SK-HEAT-W offers 1350F fixed thermal detection. • SK-HEAT-ROR-W offers 1351Ffixed and rate -of -rise thermal detection. • SK-HEAT-HT-W provides fixed high -temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Advanced thermal technology for fast response • Fixed temperature model (SK-HEAT-W) factory preset to 135OF (57°C) • Rate -of -rise model (SK-HEAT-ROR-W), 15°F (8.3°C) per minute • High temperature model (SK-HEAT-HT-W) factory preset to 190OF (88°C) • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink every time the unit is polled • 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature MWA_ • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases • Optional flanged surface mounting kit Honeywell SILENT' KNIGHT APPLICATIONS Use thermal detectors for protection of property. For further information, refer to manual 156-6529, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backboxwhich is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet I56-3627 for device limitations between isolator modules and isolator bases. PRODUCT LINE INFORMATION SK-HEAT-W: White, low -profile intelligent 1350F fixed thermal sensor SK-HEAT-ROR-W: White, low -profile intelligent rate -of -rise thermal sensor SK-HEAT-HT-W: White, low -profile intelligent 190OF fixed thermal sensor B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of 3300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B200S-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B210LP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00:Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351637:13 • 7/1/2019 SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Size: 2.0" (5.3 cm) high; base determines diameter -B300-6: 6.1" (15.6 cm) diameter -13501: 4" (10.2 cm) diameter For a complete list of detector bases, see S K-61045. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. Operating temperature range: SK-HEAT-W, . UL Listed: S6228 SK-HEAT-ROR-W: -41Fto 1001E • FM Approved (-200C to 381C) • CSFM: 7270-0559:0511 SK-H EAT-HT-W: -41F to 1501F (-20/C to 66/C) Detector spacing: UL approved for 50 ft. (15.24 m) centerto center; FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity:10% — 93% non - condensing Thermal ratings: Fixed -temperature set point 1351F (5710, rate -of -rise detection 150F (8.31C) per minute, high temperature heat 190OF (88/C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled) LED current (max.): 4.5mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.sitentknight.com 351637 1 B 1 07/19 ©2019 Honeywell International Inc. Honeywell SILENT' WGHT