Loading...
FIR2023-0003+Fire_Sprinkler_Equipment_Specification_Sheets+1.13.2023_1.16.18_PM+3314174RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2023-0003 Columbia Fire S ►KINKIER SYSTEM SERVICE A fE►AIR MANUFACTURER'S DATA SHEETS (Material Submittal) Prepared For Angle Residence Authority Having Jurisdiction Edmonds Prepared By: Najeeb Columbia Fire Inc. 111 South Findlay St. Seattle WA 98108 Phone: (206) 232-8569 Fax (206) 340-6100 Columbia Fire Project #:2210082 TABLE OF CONTENTS 1. Piping 2. Fittings / Couplings 3. Sprinkler Heads and Accessories 4. Miscellaneous Hanging Components 5. Riser and Backflow 1. PIPING Tyco Fire Protection Products BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Worldwide www.tyco-fire.com Contacts Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 Page 2of2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. �ii�CO BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products 2. FITTINGS / COUPLINGS Sprinkler Head Adapters BRASTICT"" Adapter Straight Size (inches) Part Number Box Qty 40 3/4x1/2 V5003SBT-101 100 1 x 1/2 V5003SBT-130 50 1 x 3/4 V5003SBT-131 50 900 Elbow 3/4 x 1/2 i V500735BT-101 100 1 x 1/2 V500735BT-130 50 1 x 3/4 V500735BT-131 50 Tee 1 x 1 x 1 V5012SBT-101 50 1 x 1 x 1/2 V5012SBT-130 50 1 x 1 x 3/4 V5012SBT-010 50 * Brass starter thread molded into plastic, virtually eliminating cross -threading. Female Adapter 3/4x1/2 V50035BI-101 100 with metal thread insert 1 x 1/2 V5003SBI-130 50 1 x 3/4 V5003SBI-131 10 Spigot Female Adapter 3/4x 1/2 V50032SBI-101 1 100 with metal thread insert x 1/2 V50032SBI-130 50 to1 Sprinkler Head 90 3/4x 1/2 V50073SBI-101 100 with metal thread insert 1 x 1/2 1 x 3/4 V50073SBI-130 V50073SBI-131 50 10 1-1/4x1/2 V50073SBI-166 5 Trusted above aII.T. Tee with metal thread insert ft Back to Back Cross with metal thread insert in Back to Back Tee with metal thread insert 4& Size (inches) Part Number Box Qty 1 x 1 x 1 V5012SBI-010 50 3/4 x 3/4 x 1 /2 V5012SBI-101 10 1 x 1 x 1/2 V5012SBI-130 50 1-1 /4 x 1-1 /4 x 1/2 V5012SBI-166 5 1-1 /2 x 1-1 /2 x 1/2 V5012SBI-209 5 2 x 2 x 1/2 V5012SBI-247 2 1 x 3/4 x 1/2 V5012RSBI-124 10 1-1/4x 1 x 1/2 V5012RSBI-156 5 1-1/2x 1-1/4x 1/2 V5012RSBI-199 5 2 x 1-1/2 x 1/2 V5012RSBI-237 2 1x1x1/2x1/2(1-1/8) V50353SBI5-130 1x1x12x12(1-5/16) V50353SBIL-130 1/2 x 1/2 x 1 (1-v8) V501 133SBIS-075 1/2x1/2x1(1-5/16) V501133SBIL-075 20 1 30 30 VIKING LCPVC System Quick Reference Guide 2 CPVC Standard Fittings Tee Size (inches) Part Number Box Qty Reducing Tee Size (inches) Part Number Box Qty 3/4 V5011-007 250 3/4 x 3/4 x 1 V5011 R-102 10 1 V5011-010 1004% 1 x 3/4 x 3/4 V5011 R-125 100 1-1/4 V5011-012 25 1 x 3/4 x 1 V5011 R-126 10 1-1/2 V5011-015 25 1 x 1 x 3/4 V5011 R-131 100 2 V5011-020 2 1-1/4x1x3/4 V5011R-157 5 2-1/2 V5011-025 1 1-1/4 x 1 x 1 V5011 R-158 25 3 V5011-030 1 1-1/4x1x1-1/4 V5011R-159 5 1-1/4 x 1-1 /4 x 3/4 V5011R-167 25 900 Elbow 1-1/4 x 1-1 /4 x 1 V5011 R-168 25 3/4 V5007-007 250 1 V5007-010 100 1-1/4x1-1/4x1-1/2 V5011R-169 5 1-1 /2 x 1-1 /4 x 3/4 V5011 R-201 5 1-1/4 V5007-012 25 1-1 /2 x 1-1 /4 x 1 V5011 R-202 5 1-1/2 V5007-015 25 1-1 /2 x 1-1 /2 x 3/4 V5011 R-210 25 2 V5007-020 2 1-1/2x1-1/2x1 V5011R-211 25 2-1/2 V5007-025 1 1-1/2 x 1-1/2 x 1-1/4 V5011R-212 5 3 V5007-030 1 1-1/2 x 1-1 /2 x 2 V5011 R-213 5 1 x 3/4 V5007R-131 100 2 x 2 x 3/4 V5011 R-248 2 2 x 2 x 1 V5011 R-249 10 450 Elbow 3/4 V5006-007 250 2 x 2 x 1-1/4 V5011 R-250 2 1 V5006-010 100 2 x 2 x 1-1/2 V5011 R-251 2 1% 1-1/4 V5006-012 5 2-1/2 x 2-1 /2 x 1 V5011 R-289 1 1-1/2 V5006-015 5 2-1/2 x 2-1/2 x 1-1 /4 V5011R-290 1 2 V5006-020 2 2-1/2 x 2-1/2 x 1-1 /2 V5011R-291 1 2-1/2 V5006-025 1 2-1/2 x 2-1 /2 x 2 V5011 R-292 1 3 V5006-030 1 3 x 3 x 1-1/2 V5011 R-337 1 3 x 2 V5011 R-338 1 Cross 3/4 V5035-007 10 3 x 2-1/2 V5011 R-339 1 1 V5035-010 100 1-1/4 V5035-012 5 Bushing 1 x3/4 V5018-131 100 1-1/2 V5035-015 20 1-1/4x3/4 V5018-167 25 2 V5035-020 1 In 1-1/4x 1 V5018-168 25 2-1/2 V5035-025 1 1-1/2x3/4 V5018-210 5 1 x l x 3/4 x 3/4 V5035R-131 10 1-1/2 x 1 V5018-211 25 1-1/2 x 1-1/4 V5018-212 25 Coupling 3/4 V5001-007 250 2 x 3/4 V5018-248 2 1 V5001-010 100 2 x 1 V5018-249 2 1-1/4 V5001-012 25 2 x1-1/4 V5018-250 2 1-1/2 V5001-015 25 2 x1-1/2 V5018-251 2 2 V5001-020 10 2-1/2x1 V5018-289 15 2-1/2 V5001-025 1 2-1/2 x 1-1/4 V5018-290 1 3 V5001-030 1 2-1/2x1-1/2 V5018-291 1 2-1/2 x 2 V5018-292 1 Reduced Coupling 3 x 1-1/2 V5018-337 15 1 x3/4 V5001R-131 10 3 x 2 V5018-338 1 1-1 /4 x l V5001 R-168 5 3 x 2-1/2 V5018 339 1 40 1-1/2 x 3/4 V5001 R-210 5 1-1/2 x l V5001 R-211 5 1-1/2x1-1/4 V5001R-212 5 Cap 3/4 V5017-007 250 2 x 1 V5001 R-249 2 1 V5017-010 100 2x1-1/2 V5001R-251 2 1-1/4 V5017-012 5 1-1/2 V5017-015 5 2 V5017-020 2 2-1/2 V5017-025 1 3 V5017-030 1 November 2014 LCPVC System Quick Reference Guide CPVC Pipe 3 Size (inches) Part Number Box Qty 3/4 34PIPE 240 1 1PIPE 180 ,v� r%r1v 1-1/4 114PIPE 105 As •• V 1-1/2 112PIPE 75 2 2PIPE 60 2-1/2 212PIPE 30 3 3PIPE 15 CPVCTransition Fittings Female Adapter Size (inches) Part Number Box Qty Grooved Coupling Size (inches) Part Number Box Qty with metal thread insert Adapter 3/4 V5003BI-007 10 1-1/4 V5001G-012 30 1 V5003BI-010 50 1-1/2 V5001G-015 25 1-1/4 V5003BI-012 5 2 V5001G-020 15 1-1/2 V5003BI-015 5 2-1/2 V5001G-025 4 2 V5003BI-020 2 3 V5001G-030 2 Spigot Female Adapter 3/4 V50032BI-007 250 Standard Union 3/4 V5033E-007 1 with metal thread insert 1 V50032BI-010 100 1 V5033E-010 1 . 0 Male Adapter 3/4 V5004BI-007 10 with metal thread insert 1 V5004BI-010 10 1-1/4 V500461-012 5 1-1/2 V5004BI-015 5 2 V5004BI-020 2 Accessories Solvent Cement Size (inches) Part Number Box Qty Dauber Size (inches) Part Number Box Qty `+— Quart V5097Q 12 � Small V5093-5 100 O Pint V5097P 12 Large V5093-L 100 Test Plug 1/2 V450-005 50 Roller N/A V5097 24 0 Brush N/A V5096 12 November 2014 CPVC System Quick Reference Guide 4 Recommended Installation Practices and Precautions for Freedom' CPVC Systems Dos • Install product according to the manufacturer's instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or fire stop materials are compatible with BlazeMaster® CPVC. Use only latex -based paints if painting is desired. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Follow proper handling procedures. • Use tools designed for use with plastic pipe and fittings. • Use proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end before solvent cementing. • When solvent cementing, rotate the pipe 1/4 turn when bottoming pipe in fitting socket. Always apply solvent cement to the pipe first then fitting. • Avoid puddling of solvent cement in fittings and pipe. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16"of the pipe. • Install BlazeMaster CPVC pipe and fittings in wet systems only or specially listed dry systems. • Follow manufacturer'hs recommendations for freeze protection. • Allow for movement due to expansion and contraction. • Renew your BlazeMaster CPVC pipe and fittings installation training every two years. • Follow manufacturer's recommendations on pressure testing. • Follow current NFPA standards for use of antifreeze solutions. Blazemaster® is a registered trademark of Lubrizol Teflon® is a registered trademark of E. I. du Pont de Nemours and Company Crisco® is a registered trademark of the J.M. Smucker Company Regional Headquarters Don'ts • Do not use petroleum or solvent -based paints, sealants, lubricants or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not use both Teflon® tape and thread sealants simultaneously. • Do not use solvent cement that exceeds its shelf life or has become discolored or gelled. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to BlazeMaster® CPVC grooved adapters. • Do not thread BlazeMaster CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test until recommended cure times are met. • Do not use dull or broken cutting tool blades when cutting pipe. • Do not use BlazeMaster CPVC pipe that has been stored outdoors unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install BlazeMaster CPVC pipe in cold weather without allowing for expansion. • Do not install BlazeMaster CPVC pipe and fittings in dry systems, unless specifically Listed for such use. • Do not use ratchet cutters below 50°F. • Do not use edible oils such as Crisco® as a gasket lubricant. • Do not install tape, insulated wire, or cable in direct contact with BlazeMaster CPVC pipe. Note: This list does not constitute as a complete installation guide. Viking SupplyNet - U.S. East Viking SupplyNet - U.S. Midwest Viking SupplyNet - U.S. West 4B Cranberry Rd 2353 International St 9101 Sorensen Ave. Parsippany, NJ 07054 Columbus, OH 43228 Santa Fe Springs, CA 90670 Phone: 800-845-4645 Phone: 800-926-7757 Phone: 800-366-1727 Fax: 269-818-1639 Fax: 614-527-5818 Fax: 562-944-1058 Viking SupplyNet - U.S. South Viking SupplyNet - Latin America Viking SupplyNet -Canada 100 Piedmont Court, Suite A 2840 SW 42nd St, Port 95 Ind Ctr Big IV 325 Vaughan Valley Blvd. Doraville, GA 30340 Hollywood, FL 33312 Woodbridge, Ontario L4H 3135 Phone: 800-234-2443 Phone: 954-791-1756 Phone: 905-856-3557 Fax: 770-446-3713 Fax: 954-791-1614 Fax: 905-856-3558 November 2014 Viking 1 210 N Industrial Park Drive, Hastings, MI 49058, Telephone: (269) 945-9501, Facsimile: (269) 945-9599 1 www.vikinggroupinc.com MKT-1089 3. Sprinkler Heads and Accessories Page 1 of 5 rR: FREEDOM° RESIDENTIAL CONCEALED PENDENT N4 I KJ SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS ut US UL Listed (C-UL-US-EU): Category VKKW Eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 *C) Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom' Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F_012116 Rev 17.2 (added stainless steel cover plates) Page 2 of 5 rR: FREEDOM° RESIDENTIAL CONCEALED PENDENT N4 I Ki SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/2" ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature (Required)3 Number' Number° Number' 13504 or 13642 or Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 15394 Red 218766 218756 13504 or 13642 or Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 153947 Green 218766 218756 Sprinkler Finishes: Brass and ENT Cover Plate Finishers: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatingss: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. a. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 18.04.12 Rev 18.1 Page 3 of 5 rR: FREEDOM° RESIDENTIAL CONCEALED PENDENT N4 I Ki SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number I SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,s Spacing Ceiling Type Ft. 155 °F (68 °C), 200 °F (93 °C) Temperature ° ` Ft. X Ft. (m) (m X m) Rated Sprinklers V 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with Cover Plate See Footnotes 7,9, 10, 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8. & 11 (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. a. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the "Flow" and "Pressure' for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow' and "Pressure" used. 7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). e. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. e. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. a C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). Form No. F_012116 18.04.12 Rev 18.1 Page 4 of 5 rR: FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** �qw Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) neter opening aired in the ing. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 18.04.12 Rev 18.1 Page 5 of 5 rR: FREEDOM° RESIDENTIAL CONCEALED PENDENT N4 I Ki SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT �£ N00 2-9/16" (65 mm) Maximum 2-1/16" (52 mm) Minimum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers 2-3/4" (70 mm) or 3-5/16" (84 mm) - -' ' - \- . ......I Figure 4: Square Cover Assembly 15394 Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F_012116 Rev 17.2 (added stainless steel cover plates) 4. Miscellaneous Hanging Components ODTOLCO" a brand of NIBCO' mac® Fig. 24 Hanger For CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range — 3/4 thru 2 inch CPVC pipe. Material — Carbon Steel, Pre -Galvanized. Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (WL) to support fire sprinkler piping. Meets and exceeds the requirements of N.F.P.A. 13, 13R, and 13D. Features — Figure 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre drilling of a pilot hole in wood is required. Finish —Pre -Galvanized. Order By— Figure number and CPVC pipe size. * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Revision 5/24/2001 CPVC A B C Max. Hanger Fastener Hex Approx. Pipe Size Spacing (Ft.) Head Size Wt./100 3/4 2-5/16 1-5/32 1-3/16 5-1/2 5/16 9 1 2-5/8 1-5/16 1-3/16 6 5/16 9 1-1/4 3 1-1/2 1-3/16 6-1/2 5/16 11 1-1/2 3-1/4 1-5/8 1-3/16 7 5/16 12 2 3-11/16 1-27/32 1-3/16 8 5/16 15 ® Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruitridge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com Pipe Clamps Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe ** ®TOLCO Size Range: — 3/4" (20mm) through 2" (50mm) Material: — Steel, Pre -Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand -Off' design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" (7.9mm) extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4" x 1" talk type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. Fig. 27B 0 (1)Required ir High Side of yHanger Application Hanger Application Fig. 27B (2) Required' Hanger and Restraint Application Pipe Size A B C Max Hanger Approx. Spacing W000 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) lbs. (kg) 28-3/4 3/4" (20) 31/32" (77.0) 2" (50.8) 31/2" (88.9) 51/2 (1.67) 18 (8.1) 28-1 V (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 6 (1.83) 21 (9.5) 28-11/4 11/4" (32) 35/8" (92.1) 23/8" (60.3) 31/2" (88.9) 61/2 (1.98) 23 (10.4) 28-11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2" (88.9) 7 (2.13) 31 (14.0) 28-2 2" (50) 41/2" (114.3) 211/16" (68.3) 35/8" (92.1) 8 (2.44) 34 (15.4) C&us LISM .f :a f,1 Y� B-Line by E_t•N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions CPVC Clamps TOLCO'"° Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending CPVC Max Hanger Approx. Pipe size Spacing wt./100 Part No. in. (MM) Ft. W lbs. (kg) 29-3/4 3/4" (20) 5'-6" (1.67) 18 (8.1) 29-1 1" (25) 6'-0" (1.83) 19 (8.6) Reduced Spacing For IPS Pipe IPS Max. Hanger Pipe Size Spacing Part No. in. (nun) Ft. (m) 29-3/4 3/4" (20) 1"-9" (1.67) 29-1 V (25) V-10" (1.83) Double Offset Single Offset 9 c& LISTED Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 40 B-Line series Fire Protection Solutions 5. RISER AND BACKFLOW Model 8000/8011 RESIDENTIAL RISERPACK TM Pre -Assembled TESTANDRAIN® Riser Sizes: 1" 11/a" 11/2 211 The AGF RESIDENTIAL RISERPACKT" Model 8000/8011 is a prepackaged economical riser assembly designed for NFPA 13D and 13R residential fire sprinkler systems. The one-piece casting provides required NFPA signage on both sides allowing for left or right installation and are available with grooved, threaded, or thread x groove ends. Threaded ends allow for easy connection to metal or plastic piping systems and grooved ends use approved rubber gasket couplings for secure connections. • Complies with NFPA requiements regarding testing through a properly sized test orifice • 1 " Models are available to meet nominal K-factor requirements of 2.8 to 5.6 • 1 " 8000 Models utilize a 3/a" ball valve with patented TESTANDRAIN° orifice specific outlet designed to accept either a standard garden hose or hard piped drain line • 11/4", 11/2", and 2" Models are available with orifices to meet K-factors of 2.8 to 11.2 • 11/a", 11/2", and 2" 8000 Models utilize a UL Listed/FM Approved Model 3011 BV INSPECTOR'sTESTT" ball valve • Cast and machined bronze made in the U.S.A. • Includes UL Listed/FM Approved AGF Model 7500 Pressure Gauge (300 PSI); 13R Models also include Model 7600 3-Way Globe Valve • Available as the Model 8011 with UL Listed/FM Approved Model 7000 Pressure Relief Valve (11/a"-2") or Model 7200 Pressure Relief Valve (1 ") designed to provide relief, test, and drain through a single valve 3/8",'/6", 1/2% 17/32", and 5/3" (ELO) orifice sizes • Larger size risers are available on special order NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. SS-M8000M80114002 - 01/15 TESTANDRAIN® and REmoTETEST® are registered trademarks of AGF Manufacturing Inc. Model 8000/8011 � RESIDENTIAL •o• RISERPACK TM 1" Model 8000 Dimensions 1" Model 8011 Model SIZE A B C D 1 101/2 121/4" 43/4" * 61/4" (267 mm) (311 mm) (121 mm) (159 mm) 0 11/a" 11 " 121/4" ** 4" 61/2" 00 (279 mm) (311 mm) (102 mm) (165 mm) 0 11/2" 12" 121/2" ** 41/8" 65/8" (305 mm) (317 mm) (105 mm) (168 mm) 2" 12" 13" 43/8" 67/8" (305 mm) (329 mm) (111 mm) (174 mm) 1 101/2 121/4" 27/8" **' 61/4" (267 mm) (317 mm) (73 mm) (159 mm) 11/a" 14 3/4 15" 4" 61/2" 0 00 (375 mm) (381 mm) (102 mm) (165 mm) 0 11/2" 151/4" 151/4" 41/8" 65/8" (387 mm) (387 mm) (105 mm) (168 mm) 2" 151/4" 153/4" 43/8" 67/8" (387 mm) (399 mm) (111 mm) (174 mm) *Additional space may be necessary to allow for hard drain fitting if required "Valve handle clearance required - add 2" **"Lift handle clearance required - add 31/8" n MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone:610-240-4900 Fax:610-240-4906 www.testandrain.com 1'/4"-2" Model 8000 11/4"-2" Model 8011 B 4 9 10 5 f 3 8 A 14 16 I—D 12 17 16 13� I 15 C — Components Item No. Part Qty. 1 RiserPACK - Bronze Casting 1 2 3/4'' Male x Female Ball Valve 1 3 1 " M3011 BV INSPECTOR'sTEST Valve 1 4 M7500 Pressure Gauge (1/4" 3-Way Globe Valve Included for 13R Systems Only) 1 5 Water Flow Alarm Switch 1 6 3/4'' MNPT x 1/2" FNPT Hose Adaptor Orifice 1 7 M7200 3/4" Pressure Relief Valve 1 8 M70001/2" Pressure Relief Valve 1 9 1 " Brass Nipple 1 10 1 " Brass Street Elbow 1 11 1/2" Brass System Access Port Plug 1 12 1 " Relief Valve Bypass Nipple 1 13 1 " Relief Valve Bypass Tee 1 14 1/2" NPT x-Barb Straight Fitting 1 15 1/2" NPT x-Barb Elbow Fitting 1 16 Clamps 2 17 Nylobraid Relief Valve Drain Tubing 1 Job Name: Architect: Engineer: Contractor: