REVIEWED FIR2023-0052+Fire_Sprinkler_Equipment_Specification_Sheets+5.31.2023_8.44.07_AM+3577323RECEIVED Jun 01 2023 FIR2023-0052 CITY OF EDMONDS DEVELOPMENTSERVICE DEPARTMENTMENT ED HAWK FIRE PROTECTION LLC 801 Valley Avenue N.W. Suite D Puyallup, WA 98371 (253) 840-9900 N M0-0�0=� "q Z;6/e- V Aaff e FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR Haider Residence Edmonds, WA RHFP JOB NO. 80384 TABLE OF CONTENTS Description Spears_CPVC Piping System Description Anvil, CPVC Hanger, Fig 187 Anvil, CPVC Hanger, Fig 188R Tolco, CPVC Hanger, Fig. 29 WRED I" IAWK FIRE PROTECTION, LLC Comments Or equal listed CPVC piping Comments Or equal listed CPVC Hanger Or equal listed CPVC Hanger Or equal listed CPVC Hanger Section. Accessories Description Comments Aollo, Backflow Double Check Assembly, Model DC4A First Option if availble Ames, Backflow Double Check Assembly, Model 2000E If Apollo DC4A is unavailble Description Comments Potter, Waterflow Switch, VSR-SG Or Listed equal Potter, 6" 120V Electric Bell, PBA1206 Or Listed equal Description Comments Reliable, Concealed Pendent Sprinkler, 4.9K, RA0616 Reliable, Recessed Sidewall Sprinkler, 4.41K, R3531 Page 1 of 1 Piping and Fittings Submittal Information for Spears° Manufacturing Company pil I FlameGuard ° CPVC Fire Sprinkler System Date: Job Name: Engineer: Scope: This submittal covers the Spears® FlameGuard® CPVC Fire Sprinkler System suitable for residential and light hazard occupancies in accordance with The National Fire Protection Association (NFPA). The FlameGuard® System shall be sold as a complete system which consists of pipe, fittings and a specially formulated one-step primerless cement intended for use in wet, dry and pre -action systems in residential and light hazard Applications where the operating temperature/pressure does not exceed 175psi @ 150' F. (1.2 MPa @ 66' C) Product Specification: All CPVC fire sprinkler fittings and pipe shall be Spears® FlameGuard®. All solvent cement shall be Spears® FS-5 One -Step, and all thread sealant shall be Spears® Blue 75Tm as produced by Spears® Manufacturing Company. All Spears® FlameGuard® CPVC fire sprinkler fittings shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Fittings shall be manufactured in strict compliance to ASTM F438 or F439, as applicable. All CPVC fire sprinkler piping shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Piping shall be manufactured in strict compliance to ASTM F442. All CPVC solvent cement shall be a primerless, one-step type manufactured in strict compliance to ASTM F493 and approved for use with CPVC fire sprinkler systems. All CPVC fire sprinkler fittings, pipe and solvent cement shall be listed by Underwriters Laboratories (UL®), Underwriters Laboratories Canada (ULC®) and/or Factory Mutual Research Corporation (FM Global) and/or LPCB for use in residential and light hazard wet, dry and pre -action systems and bear their authorized certification marks. Thread sealant shall be approved by the fitting manufacturer for use with CPVC fire sprinkler products. All CPVC fittings, pipe, solvent cement and thread sealant shall be certified by NSF International as applicable. Pipe and solvent cement shall be certified to UL 2818 GREENGUARD GOLD. Product Marking: FlameGuard® system components shall be orange in color for identification and include required markings and approvals prescribed in ASTM F442 for pipe GSFG-0221 Location: Contractor: and ASTM F438 or F439 for fittings. Pipe and cement shall have GREENGUARD GOLD marking. Installation: Spears® FlameGuard® CPVC Fire Sprinkler System shall carry a working pressure of 175 psi @ 150F (1.2 MPa @ 660 C) and shall be installed in accordance with Spears® Manufacturing Company FlameGuard® CPVC Fire Sprinkler Products Installation Instructions (FG-3) and Addendums. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the Installation Instructions and applicable local codes. Installation practices such as pipe support spacing, bracing, allowance for thermal expansion/contraction, solvent cementing and handling and storage shall be in accordance with the manufacturer's instructions and this specification. Buried pipe shall be in accordance with NFPA 24 for supply mains. The piping system shall be joined using a chemically resistant one-step primerless solvent cement joining process conforming to ASTM F493. The system shall be protected from ultra violet (UV) light exposure from the sun or other source and protected from any chemicals that are not compatible with the CPVC materials including but not limited to fire stopping materials, plasticizers, incompatible thread sealants, etc. NOTE: FlameGuard® CPVC piping systems can be leak tested using oil -free compressed air up to 25psi but must also be hydrostatically tested as required per NPFA standard. Referenced Standards: ASTM D1784 — Rigid Vinyl Compounds ASTM F438 — CPVC Schedule 40 Fittings ASTM F439 — CPVC Schedule 80 Fittings ASTM F442 — CPVC SDR Pipe ASTM F493 — Solvent Cements for CPVC Pipe & Fittings NFPA 13, 13D, 13R — National Fire Protection Association Standards NFPA 24 — Installation — Private Fire Service Mains NSF International Standard 14/61 — Potable Water Approvals: NSF° — NSF International Standard 14/61 — Potable Water Underwriters Laboratories — Listing Agency FM Global —Listing Agency UL-GREENGUARD GOLD Certified UL 2818 LPCB — Loss Prevention Council Board %v ,,,, Hangers & Sway Bracing CPVC Z ANVIL Fig. 187 (Formerly Afton Fig. 511) TWo Hole 90° Side Mount Strap Size Range: 3/4" through 2" Finish: Zinc Plated Steel (Hot -Dip Galvanized optional) Service: Hanger for CPVC pipe in the horizontal position on the bottom of structural wood 7 beams and Steel 20 Ga. (min.) (Fig. A). Can be used as a restrainer, only in Stee120 Ga. (min) (Fig. 8). During installation, adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger, minimizing vertical pipe movement. Approvals: UL and ULC Listed. Installation: i • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. y • Do not anchor tightly to mounting surface. Pipe must be allowed to move freely through hanger. • Steel applications require two (2) #14 x 1" hex washer head self -drilling TEK screws. Not Supplied. Part Number STD-0090. c UL us Features: LISTED • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. No pre -drilling required. Ordering: Specify CPVC pipe size, figure number and description. Fig. A Fig. B FIG.187: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B ttC E F Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) 3/4 1'/ 6 11/2 3/ 6 13/16 21/2 51/2 5 1 1 19/ 6 3/ 6 13/ 6 23/4 6 6 11/4 13/16 13/4 13/ s 113/1s 131/4 1 61/z 7 1 1/2 1'/16 111/ 6 1 3/ 6 1 13/16 1 31/z 1 7 8 2 1'/16 21/8 1 3/ 6 1 13/ 6 1 313/ 6 1 8 9 PROJECTi• rAPPROVAL Project: []Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-11.19 CPVC Z ANVIL ..T....I.-I Fig.188R (Formerly Afcon Fig. 514) Size Range: 'A" through 2" Material: Carbon Steel Finish: Pre -Galvanized per ASTM A653 Service: Two Hole Standoff Hanger & Restrainer • Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed on the top, bottom, and side of the supporting structure. • Guide for vertical CPVC, steel, and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. • Easily attaches to wood structure with #10 x 1" hex washer head self -threading screw supplied with product. No pre -drilling required. • Bottom of pipe is offset 11/2" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer Hange Restra D& 'ainer Installation - Backing Nut Hanger =1 - at top fastener Restraint = 2 - on each fastener Per NFPA-13D and NFPA-13R PROJECT INFORMATION Project: APPROVAL []Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-07.20 CPVC Z ANVIL ..T....I.—I F1g.188R (Formerly Afcon Fig. 514) TWo Hole Standoff Hanger & Restrainer (cons.) a p 4..p a d. . p d dp dp. d Q p. d u Hanger and Restrainer B = A E -(D- + OC � \ , (r::: L / FIG.188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B 0C D E F G Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) 3/4 23/4 31/2 1/4 2 1 2% 11/2 51/2 11 1 21'/16 31/2 1/4 2'/16 1 2"/16 11/2 6 12 11/4 213/ 6 31/2 1/4 25/ 6 1 31/4 11/2 61/2 13 11/2 3% 41/4 1/4 27/6 1 31/2 11/2 7 14 2 311/16 4% 1/4 211/16 1 4 11/2 8 16 FIG.188R: LISTED FASTENERS Pipe Wood and Composite Beams Steel (18ga. Minimum) CPVC Screw Supplied or #10 x 1 " TEK Screw #14 x 1 " TEK Screw or 1/4" x 1 " TEK Screw Steel & Copper #14 x 1 " TEK Screw or 1/4" x 11/2" Lag Screw #14 x 1 " TEK Screw or 1/4" x 1 " TEK Screw PH-07.20 Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe** Size Range: Available in 3/4" (2omm) and 1 " (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1" hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending ** With reduced spacing, consult factory. Double Offset Single Offset 9 0 0 O 11m (38.1 mm) ®TOLCO c&uS LISTED 1 1.5" (38.1 mm) }-----------, 1---= .5° (38.1 mm) Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Valves and Accessories ES-A-2000B Job Name Job Location Engineer — Approval — Series 2000B Double Check Valve Assemblies Sizes: 1/2" - 2" Series 2000B Double Check Valve Assemblies are designed to protect drinking water supplies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non -potable service applica- tions such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design •'/2" - 2" Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" - 1 " have tee handles f ,. It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water author- ity, building and plumbing codes. Contractor Approval Contractor's P.O. No Representative 1/4" 2000B Ina&@ ®• (20mm) -9 a. - 2" 2000B HC (50mm) Specifications A Double Check Valve Assembly shall be installed at each not- ed location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Fire & Waterworks Series 2000B. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. A M E Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. A WATTS Brand Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Dimensions - Weights Standards AWWA Std. C510, IAPMO PS31 ��pSSIFjFo Approvals ac s A ® ° ® c �L us 1015 B64.5 3/411- 211 (LBV Models Only) • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. (Excluding all LBV Models) • Horizontal and vertical "flow up" approval on all sizes. Suffix HC — Fire Hydrant Fittings dimension "A" = 231/2" (594mm) 10 G 0 SIZE DIMENSIONS WEIGHT in. A in. mm in. B mm C in. mm in. F mm G in. mm H in. mm I in. mm lbs. kgs. 1/2 10 254 4% 117 2'/16 62 5 127 33/6 85 25/6 59 21/16 52 4.5 2 3/4 111/8 282 4 102 31/6 79 63/6 157 Y/16 87 21/6 54 15/6 33 5 2.3 1 131/4 337 51/6 130 4 102 71/2 191 33/8 85 111/16 43 111/16 43 12 5.4 11/4 163/8 416 5 127 35/16 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 163/4 425 4'/6 124 31/2 89 93/4 248 513/16 148 31/6 79 211/16 68 15.86 7.2 2 191/2 495 1 61/4 159 1 4 102 1 133/6 340 1 61/8 156 1 37/16 87 1 211/16 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 11211 y 83 12 0 69 10 55 8 41 6 H 28 4 ayi 14 2 a 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi H 152 22 J 124 18 96 14 N 69 10 0. 41 6 14 2 31,11 gpm kPa psi 96 14 w 83 12 o 69 10 y 55 8 j 41 6 d28 4 L 14 2 0 0 411,11 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 1112 kPa psi A 83 12 69 10 N 0 55 8 41 6 y 3 28 4 y 14 2 0 0 L pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate ur 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi y 110 16 A 0 83 12 y 69 10 55 8 y 41 6 28 a P a 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gp AP 0 19 38 57 76 95 114 133 152 171 190 209 2281p 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate A M E S FIRE & WATERWORKS TS A WATBrand ES-A-2000B 1735 kPa psi J a m 2" y 83 12 p 69 10 55 8 41 6 0 N 28 4 i 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm m 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 81-1001-8600 • AmesFireWater.com © 2017 Ames Fire & Waterworks Valves APD&O UBMITTAL SHEET DCLF4A & DC4A Double Check Valves - A Series Job Name: Job Location: Engineer: Contractor: Tag: PO#: Rep: Wholesale Dist.: DESCRIPTION The Apollo" Model DC4A and DCLF4A Series Lead Free* & Non -Lead Free Double Check Valves prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are objectionable to the potable water supply, but non -health hazards. The top accessed modular check valve cartridges provide captured springs, replaceable seats and reversible silicone seat discs. This Made in America assembly features ball valve shutoffs with stainless steel handles and nuts as standard and carries the five-year Apollo° factory warranty. FEATURES • Low Pressure Loss • Captured Spring Cartridge Check Valves • Compact, Yet Easy to Maintain • Ball Valve Shut -Offs w/ SS Handles & Nuts Standard • Top Access for Fast Testing & Maintenance • Threaded Testcock Protectors • Corrosion Resistant • No Special Tools Required • 5 Year Warranty • Lead Free Option • Chloramine-Resistant Elastomers • Designed, Cast, Machined, Assembled and Tested in the USA DIMENSIONS PERFORMANCE RATING • Maximum Working Pressure:175 psi • Temperature Range: 33°F -180*F APPROVALS • Horizontal and Vertical Up Approvals • AW WA C510 • Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California • ASSE 1015-2011 • IAPMO • CSA B.64.5 MODEL NUMBER SIZE (IN.) DIMENSIONS (IN.) WT. (LB.) A B C D 4A-103-A2F 112" 10-7/8 7-3/8 3-1/4 2-1/2 4.1 4A-104-A2F 3/4" 12-5/8 8-1/2 3-1/2 3 5.4 4A-105-A2F 1" 14-5/8 9-1/2 4 3-1/4 9.0 4A-106-A2F 1-1/4" 17-1/2 11-3/4 4-1/2 4-3/4 9.1 4A-107-A2F 1-112" 18 11-5/8 4-1/2 4-3/4 12.9 4A-108-A2F 2" 20-1/8 12-3/4 5 5-3/8 16.5 PART NUMBER MATRIX ■ STANDARD MATERIALS LIST Bronze C84400 or BODY, CAPS C89836 Lead Free' Bronze C84400 or BV SHUTOFFS, TEST COCKS C87800 Lead Free" CHECK VALVE CARTRIDGES Glass -Filled PPO SPRINGS 300 Series Stainless Steel SEAT DISCS Chloramine-resistant Silicone C I— B —I A 4A [XI 1 X X X X X Y-STRAINER SIZE SHUT-OFF VALVES OPTIONS (CAN BE COMBINED) 4A - STANDARD 0 STANDARD 3 - 1/2" A2 - W/BALL VALVES (STANDARD) F - SAE THREADED TEST COCKS (STANDARD 1/2" -2") 4ALF - LEAD FREE 1 W/Y-STRAINER 4 - 3/4" A4 - W/UNION BALL VALVES (3/4" - 2") ILL - SS LOCKING LEVER HANDLES (SHIPPED LOOSE) 5 - 1" PR - PRESS CONNECTIONS (FACTORY INSTALLED) 6 - 1-1/4" P - PUSH (3/4" -1") CONNECTIONS (FACTORY INSTALLED) 7 - 1-1/2° EXAMPLE: 4A 104 A4LL = 3/4" double check valve assembly with union ball valves with locking lever handles 8 - 2„ *LEAD FREE The wetted surfaces of this product shall contain no more than 0.2596lead by weighted average. Complies with Federal Public Law 717-380. ANSl3rd party approved and listed. Mr (704) 841-6000 This specification is provided for reference Mly Apollo reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Apollo products previously or subsequently sold. integrated apollovalves.com Most current information available at apollovalves.com. piping Systems SS1380 ©10/18 Page 1 of 2 aalberts Valves APD&O UBMITTAL SHEET FLOW CURVES 7.5 fps 1 /2" 7.5 fps 3/4" 20 18 a 16 u) 14 U) OJ 12 W 10 D U) 8 w 6 IL 4 2 DC4A & DCLF4A r Double Check Valves - A Series LEAD FREE 7.5fps1" 7.5fps11/4" 20 18 U) 16 n 14 U O 12 LLJ 10 3/4" Al' D CO 8 i U) W 6 t7 a 4 2 0 10 20 30 40 RATE OF FLOW (GPM) 20 7.5 fps 1 1 /2" 7.5 fps 2" 18 a 16 14 O 12 10 D 1 1 /2" 2" / 8 L i O 6 a 4 _ 2 0 20 40 60 80 100 120 140 160 180 200 220 240 RATE OF FLOW (GPM) 0 10 20 30 40 50 60 70 80 90 100 110 RATE OF FLOW (GPM) (704) 841-6000 This specification is provided for reference only. Apollo reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Apollo products previously or subsequently sold. integrated apollovalves.com Most current information available at apollovalves.com. Apiping Systems SS1380 ©10/18 Page 2 of 2 aalberts Alarms & Supervisory Devices GP� POTTER The Symbol of Protection VSR-SG VANE TYPE WATERFLOW FOR CPVC PIPE ALARM SWITCH WITH RETARD AND GLUE -IN UNION Specifications subject to change without notice. Stock Number: 1144460 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating switch to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. General Information The Model VSR-SG is a vane type waterflow switch for use on wet sprinkler systems using CPVC plastic fittings (manufactured by Tyco, Nibco, Victaulic, Ipex, and Spears Manufacturing Company) that use I", 1 '/4", 1 'h", or 2" pipe sizes. It is equipped with a union to accommodate installation in confined spaces. The VSR-SG contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the switch. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR-SG switches and retard switch are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation (see Fig. 1, 3, and 5) These switches may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The switch should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the switch from operating and will void the warranty. UL, CUL and CSFM Listed, CE Marked Service Pressure: Up to 175 PSI (12,07 BAR) Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) -UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Service Use: British Standard B59251 Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious iniury or death could result. within 24" (60 cm) of a valve or drain. The unit has a 1" male fitting for gluing into a CPVC plastic tee. NOTE: Do not leave cover off for an extended period of time. Loosen the union nut and separate the 1" male fitting from the VSR-SG. Glue the 1" male fitting into the TEE following the TEE manufacturer's instructions for preparation and gluing of CPVC piping systems. (Note: The 1" male fitting must bottom out on the stop of the TEE for proper operation of the VSR-SG. See Fig. 1.) Wait 2 to 4 hours to allow the glue to dry before attaching the VSR-SG to the 1" male fitting. Select the proper paddle for the pipe size and type of TEE used. See Fig. 3 for instructions on how to change paddle. Verify that the o-ring is properly positioned in its groove. Hand tighten the nut on the union after orienting the switch in the appropriate direction to detect waterflow as shown in Fig. 5 & Fig. 7. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. A CAUTION Do not over -tighten the union nut, hand tighten only. Use of a wrench may damage the union nut. PotterElectric Signal Company, LLC • St. Louis, MO • Cust Service: 866-572-3005 • Tech Support: 866-956-0988 /Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401205 - REV H PAGE 1 OF 4 01/12 VSR-SG @POTTER VANE TYPE WATERFLOW FOR CPVC PIPE ALARM SWITCH WITH RETARD The Symbol of Protection AND GLUE -IN UNION Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). A method of testing the VSR-SG must be provided. The valve used for testing shall be easily reached and shall produce a minimum flow of 10 GPM to activate the switch. The discharge orifice shall be equal to the smallest sprinkler used in the system. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 1 Glue the 1" male fitting into the TEE following the TEE manufacturer's instructions for preparation and gluing of CPVC piping systems. Wait 2 to 4 hours to allow the glue to dry before attaching the VSR-SG to the 1" male fitting. 9" (MINIMUM CLEARANCE REQUIRED FOR 1" MALE FITTING INSTALLATION OR MUST BOTTOM OUT REMOVAL OF DEVICE) ON STOP NO BUSHINGS, L� INSERTS OR DWG. #1062-1 ADAPTERS ARE PERMITTED Fig. 3 D W #1063-3 Important: 11 paddles are furnished with each unit to accommodate the various sizes and manufacturers of TEES. The paddles have raised lettering that show the pipe size and the TEE manufacturer they are to be used with. The proper paddle must be used. The paddle must be properly attached (see Fig. 3) and the screw that holds the paddle must be securely tightened. Fig. 2 Break out thin section of cover when wiring both switches from one conduit entrance. /A Fig. 4 Typical Electrical Connections Notes: 1. The Model VSR-SG has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 6). CONNECTOR NEUTRAL FROM BREAKER NEUTRAL FROM BELL )EF1__ 0 F�7� LINE FROM BREAKER EOL (End Of Line Resistor) NOTE: When connecting to a UL Listed control panel, use the panel's resistor value for circuit supervision. PRINTED IN USA MUG. #5401205 - REV H PAGE 2 OF 4 01/12 VSR-SG GP� POTTER VANE TYPE WATERFLOW ARM SWITCH WITH RETARD The Symbol of Protection AND GLUE -IN UNION Fig. 5 Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60- 90 seconds). The time delay should be set at the minimum required to prevent false alarms. OPTIONAL COVER TAMPER SWITCH — Donotleavecover fffore tendedperiod offime RETARD ADJUSTMENT KNOB MOUNT SO ARROW ON BASE POINTS INDIRECTION OF WATERFLOW 1" MALE FITTING ON ALL SIZES \ / / DWG# 1205-IA Flowing water activates switch in direction only. Fig. 7 Mounting Dimensions -Orientation 3.50 in 2..8 in (89.0 —) � (50mm) 3.91 in (99.33 —) PIPE PLASTIC PADDLE RUN OF THE TEE MAYBE 1", 1 '''W', 1 ". or 2" 10.1 PIPE Fig. 6 Switch Terminal Connections Clamping Plate Terminal 10GOMING OO1001Nu An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. A CAUTION Flow switch must be properly orientated. Side of cover must be perpendicular with the pipe. Improper orientation could delay or prevent notification of waterflow. Fig. 8 GREEN GROUND DWG# 1205-15 PRINTED IN USA MFG. #5401205 - REV H PAGE 3 OF 4 01/12 VSR-SG CP� POTTERVANE TYPE WATERFLOW FOR CPVC PIPE ALARM SWITCH WITH RETARD The Symbol of Protection AND GLUE -IN UNION Maintenance Inspect the waterflow switch monthly. If leaks are found, replace the waterflow switch. The VSR-SG waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 9). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 9) I The Retard/Switch Assembly is field -replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re -install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 9 (2) ORIGINAL MOUNTING REMOVE (2) ORIGINAL MOUNTING BREAKOUTTHINSECTIONOFCOVER SCREWS TSCREWS HOLDING RETARD/SWITCH WHEN WIRING BOTH SWITCHES •I / \ ASSEMBLY TO BASE FROM ONE CONDUIT ENTRANCE. 4/ \® RETARD/SWITCHASSEMBLY-­­� DO NOT REMOVE (2) RETARD HOUSING SCREWS Removal of Waterflow Switch (2) LOCATING PINS (2) LOCATING Pr. BOSSES IN BASF BASE IGX 1- • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and seperate unit from the glued -in fittings • Gently lift the unit far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector. • Lift detector clear of pipe. PRINTED IN USA MFG. #5401205 - REV H PAGE 4 OF 4 01/12 (E)POTTER h The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4" box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6", 8" and 10" sizes Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC PDC-6-12 1750500 200mA 96 76 8 (200) 12VDC PDC-8-12 1750502 .200mA 96 77 10 (250) 12VDC PDC-10-12 1750504 .200mA 96 78 6 (150) 1 24VDC PDC-6-24 1750501 .20mA 95 77 8 (200) 24VDC PDC-8-24 1750503 20mA 83 79 10 (250) 24VDC PDC-10-24 1750505 20mA 85 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. BELLS PBA AC & PDC-DC U U C/ FM ** ��° 9�h APPROVED * ULC on PDC-DC Only ** FM on PBA-AC Only Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non -corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note 1) Environmental -400 to 150OF (400 to 66°C) Limitations (Outdoor use requires weatherproof backbox.) AC Bells - 4 No. 18 AWG stranded wires Termination DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. BWARNING I Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. WARNIN In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 1 OF 2 (E)POTTER BELLS The Symbol of Protection PBA AC & PDC-DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions WARNING Inches (mm) Wtoinstaller down will prevent bell froWringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) _ Fig 1 53/4" _ (146 mm) 10" (250 mm) 8„ r - I (200 mm) 6" j I5/8" (150 mm) I I 211/16" (68 mm) DWG#776-1 Wiring Rear View Fig 3 D,C. BELLS (OBSERVE POLARITY) A,C, BELLS (86 mm) 4 1/4" (108 mm) 3 3/8" 5" (86 mm) (127 mm) RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) O O FROM CONTROL PANEL CBLIACK EXT BELL FROM CONTROL PANEL OR D-OF-LINE OR PRECEDING BELL SISTOR PRECEDING BELL BLACK (IN) OT) BLACK (IN) O CBLACK CAUTION - WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN, NOTES: CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 2 OF 2 Sprinklers Bulletin 006 May 2022 Reliable Features cULus Listed as Residential Sprinklers Push -On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in accordance with UL 199. In addition, Model RFCLL Series sprinklers are cULus certified for Health Effects to NSF/ANSI/ CAN 600, cULus certified less than 0.25% Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified. Model RFC Series sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible -link operating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are intermediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model G5 cover plate. Model G5 cover plates are installed by pushing the cover plate into the cup and turning in the clockwise direction until it is tight against the ceiling. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model G5 cover plates are available in a variety of finishes as listed in Table H. Model RFC Series Residential Sprinklers Flat Concealed Pendent Model RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC76 cULus Listed Model RFC43 & RFC43LL Model RFC58 Model G5 Cover Plate Sprinkler Model p Nominal K-Factor gpm/psi112 (1/min/bar112) Max. Coverage Area I ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) cULus RA0618 cULus: cULus listed for Safety to ANSI/UL199 LL: cULus certified for Health Effects to NSF/ANSI/CAN 600 cULus certified less than 0.25% Lead Content to NSF/ANSI 372 Annex G. WMCS: Australian WaterMark certified, certificate number 23347. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals* cULus Listed to UL 199 Bottom View *Note: RFC30LL is also cULus certified for Health Effects to NSF/ANSI/CAN 600, cULus certified less than 0.25% Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified (certificate number 23347). Model RFC30 & RFC30LL Sprinkler Components and Dimensions utcx1 Body Cup Tower Fusible Lii Deflector (retrac Pin (extent Deflector (extent 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling ossFicoi ozoa Model G5 Cover Plate Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Cup Dia. 3-5/16" (84 mm) Dia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure Max. Coverage Area (Z) Ordinary Temperature Intermediate Temperature(3) Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) bar) 12x12 9 9.0 9 9.0 (3.6 x 3.6) (34) (0.62) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Intermediate temperature listing applies to SIN RA0611 only; not applicable to low -lead version. Bulletin 006 Reliably Page 2 of 8 May 2022 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals" cULus Listed to UL 199 Bottom View "Note: RFC43LL is also cULus certified for Health Effects to NSF/ANSI/CAN 600, cULus certified less than 0.25% Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified (certificate number 23347). Model RFC43 & RFC43LL Sprinkler Components and Dimensions Threa Body Cup Tower Fusible Lii Deflector (retrac Pin (extent Deflector (exten< 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling 006FIG01 W 03 Model G5 Cover Plate Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Cup Diar � . 3-5/16" (84 mm) Dia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure Ordinary Temperature Intermediate Temperature Max. Coverage Area ft. x ft. Flow Pressure Flow Pressure (m x m) 9pm psi gpm psi (1/min) (bar) (1/min) (bar) 15 x 15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16 x 16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliably Page 3 of 8 May 2022 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals* cULus Listed to UL 199 Bottom View *Note: RFC49LL is also cULus certified for Health Effects to NSF/ANSI/CAN 600, cULus certified less than 0.25% Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified (certificate number 23347). Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threa - Body Cup Tower Fusible Lii Deflector (retrac Pin (extenc Deflector (extenc 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling OOBFIGOt_O?_IXi Model G5 Cover Plate Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Cup Dia. MW 3-5/16" (84 mm) Dia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure0) Max. Coverage Area(') Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 16 x 16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 18.4 (6.1 x 6.1) (75.7) (1.15) (79.5) (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a mini- mum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliably Page 4 of 8 May 2022 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 199 Model RFC58 Sprinkler Components and Dimensions Threads Body Cup Tower Fusible Link Deflector (retracted) - Pin (extended) - Deflector (extended) - Bottom View 2-5/16" (58 mm) Cup Dia. 2-5/8" (67 mm) 1-7/8" (48 mm) +/- 3/8" (9 mm) Hole in Ceiling Nominal face of fitting to ceiling M 03/16" (5 mm) OD FIGNA JE Model RFC58 Sprinkler Hydraulic Design Criteria 3-5/16" Model G5 Cover Plate (84 mm) Ceiling Dia. Minimum Flow and Residual Pressure(') Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliably Page 5 of 8 May 2022 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 199 Bottom View ° Model RFC76 Sprinkler Components and Dimensions • - Threads Body Cup �` Tower Fusible Link Deflector (retracted) - Pin (extended) - Deflector (extended) - 2-5/16" (58 mm) Cup Dia. 2-5/8" (67 mm) 1-7/8" (48 mm) +/- 3/8" (9 mm) Hole in Ceiling Nominal face of fitting to ceiling 3/16" (5 mm) 606FIG06A _ 3-5/16" Model G5 Cover Plate (84 mm) Ceiling Dia. Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure(') Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18 x 18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6.1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliablie Page 6 of 8 May 2022 www.reliablesprinkler.com Cover Plate Finishes(') Standard Finishes LSpecial Application Finishes White Paint Off White Paint Black Paint Raw Brass Chrome Bright Brass Finished Bronze Custom Color Paint(2) Satin Chrome Stainless Steel Clad(3) Custom Printed Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling0) Ceiling Rating inch (mm) inch (mm) RFC30, RFC30LL, 135°F(2) RFC431 G5 3-5/16 2-5/8 1/2 1-112 to 2 112 to 1 (57°C) RFC43LL, (84) (67) (13) (38 to 51) (13 to 25) or 165°F(3 RFC49, (74°C) RFC49LL RFC58, G5 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 13or 1�655F3C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) (74-C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the maximum ceiling temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers where the maximum ceiling temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Model RFC series sprinklers are shipped with a wrench -able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench -able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque for iron pipe fittings is 8 to 18 ft-Ibs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-Ibs (19 to 27 N-m) for 3/4" thread sprinklers. Note: When used with gasketed fittings, follow fitting manufacturer's installation instructions regarding tightening to achieve a leak -free connection. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Bulletin 006 May 2022 Page 7 of 8 www.reliablesprinkler.com � of Maintenance Model FC For use with Model RFC Series sprinklers without wrench -able cap installed Model W8 High -strength plastic wrench for limited (emergency) use with Model RFC Series sprinklers without wrench -able cap installed. Meets NFPA requirements for sprinkler wrench on premises. Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Am Model W3 For use with Model RFC Series sprinklers with wrench -able cap installed Listings and Approvals cULus Listed for Safety to ANSI/UL199 Additional Listings for RFC30LL, RFC43LL, and RFC49LL: • cULus Certified for Health Effects to NSF/ANSI/CAN 600 • cULus Certified less than 0.25% Lead Content to NSF/ ANSI 372 Annex G. • Australian WaterMark Certified, certificate number 23347. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model G5 • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 • Model W8 (Limited use) N O 0) M 0) M i 1 Bulletin 006 May 2022 Page 8 of 8 www.reliablesprinkler.com Bulletin 135 April 2021 Rel ® Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, Residential Sprinkler Summary Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non - recessed) and Model W4 (recessed, concealed) are required. fi the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1 Res Series sprinklers are listed for use in wet systems only. Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi112 (Ipm/bar'/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1 Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14 (4.3 x 4.3) F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 3.0 (43 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F(68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed" Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Ow Model F1 Res30 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) DIA. Face of fitting 1-15/16' to finished (49mm) DIA. ceiling 1/2" (13mm) Threads +/- 1/4" (6mm) Wrench Flat 'VH Sealing Assembly 2 1/4" MStll1 FOM 09 Glass Bulb (57mm) I 1-3/4" (44mm) +/- Load Screw 1/4" (6mm) Deflector 1-1/4" (32mm) 2 7/8" (72mm) DIA. Components Dimensions F2 & FV Recessed Escutcheon Installation Model F1 Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems0) Maximum Coverage Area (2) ft. x ft.(m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) 15 x 15 (4.6 x 4.6) 12 (45) 16.0 (1.1) 16 x 16 (4.9 x 4.9) 13 (49) 18.8 (1.3) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 2 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or IS07-1R1/2 Sensitivity Nominal K-Factor: 4.9 (71 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) % Thermal Sensor: 3 mm glass -bulb Recessed Escutcheons \ / Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* _ Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/_ to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2" (13mm) +/- 3/8" (9mm) +/ 1/4" (6mm) fYJStltI 2-1/4" (57) 1-5/8" (41mm) +/- 1-3/4" (44mm) +/- 3/8" (9mm) 1/4" (6mm) 1-1/4" y I I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16 (61) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18 (5.5 x 5.5) 19 (72) 15.0 (1.03) 20 x 20 (6.1 x 6.1) 22 (83) 20.2 (1.39) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 3 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting V of fitting 1-15/16'. to finished inished 4 (49mm) DIA. ceiling eiling 5/8" (1 6mm)(13mm) +/ 3/8" (9mm)4" (6mm) O�Stl� 2-1/4" (57)44mm)1-5/8" (41mm) +/-" (6mm) 3/8" (9mm) 1-1/4" I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 4 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Material Specifications 175°F (79°C) Recessed Escutcheons \ t Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy F1 Recessed F2 Recessed 1 Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches' Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting4,(49 Face of fitting 1-15/16" to finished to finished (49mm) DIA. ceiling ceiling 5/8" (16mm)1/2" (13mm) +/- 3/8" (9mm)+/- 1/4" (6mm) 09StlH 2-1/4" (57)1-3/4" (44mm)1-5/8" (41mm) +/1/4" (6mm) 3/8" (9mm) 1-5/8" I (44mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to ft. x ft. (m x m) gpm (1/min) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21 (80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 5 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model F1 Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 9_R/n'- tP,7 --. CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. :ace of fitting to finished ceiling Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) / 1/4" (6mm) +/ 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Area(z) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14 (4.3 x 4.3) 11 (38) 13.4 (0.92) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 6 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or ISO7-1 131/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 7_V/R-1 /R7mm1 CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. ace of fitting to finished ceiling i Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) /- 1/4" (6mm) o , r, r_-- r,, ,T, +/- 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. - FP Recessed Escutcheon Installation Model F1 Res49 CCP Pendent and FP Recessed Pendent Hvdraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16 x 16 (4.9 x 4.9) 14 (53) 8.2 (0.57) 18 x 18 (5.5 x 5.5) 18 (68) 13.5 (0.93) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 7 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8" (67mm) 2-5/8" (67mm) DIA. DIA. CCP Recessed Escutcheon Installation 2-5/16" (59mm)DIA. ace of fitting to finished ceiling Face of fitting to finished ceiling -- 1/4" (32mm) () 1-1/4" (32mm) - 1/4" (6mm) �, T r,,,, T„ +/- 1/4" (6mm) 11" m) (24mm4mm) L \�V +/- 1/4/4"" (6mm) 3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria - Minimum Flow and Residual Pressure in Wet Pipe Systems(' Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 112 to 1 inch (13 to 25 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 8 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Conical Concealed Pendent and (See Table N) Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F (57°C)* Thermal Sensor: 3 mm glass bulb FP Recessed* Sprinkler Frame: Brass Alloy Sprinkler Wrenches Button: Copper Alloy Model W4 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions ace of fitting to finished ceiling -1/4" (32mm) i- 1/4" (6mm) 15/16" (24mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model F1 Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria 1 -ace of fitting to finished ceiling -1/4" (32mm) /- 1/4" (6mm) 1" (25mm) /- 1/4" (6mm) Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 16 x 16 (4.9 x 4.9) 21 (80) 7.6 (0.52) 1 inch 1/2 (13 to o 25 mm) 18 x 18 (5.5 x 5.5) 22 (83) 8.4 (0.58) 20 x 20 (6.1 x 6.1) 25 (95) 10.8 (0.75) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ReliablE� Page 9 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or ISO7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1 Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41mm) 2-7/16" (62mm) 5/16" (8mm) Dimensions 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) - - DIA. DIA. +/- 1/4" (6mm) Top of Deflector Down from _ Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations F2 & FV Recessed Escutcheon Installation Model F1 Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 12 (45) 7.5 (0.52) 4 6 inches (100 to 150 mm) t 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57) 11.6 (0.80) 16 x 16 (4.9 x 4.9) 16 (61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) 18 x 18 (5.5 x 5.5) 19 (72) 18.7 (1.29) 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 10 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass -bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 1 175°F (79°C) (1) SWC Cover Plates SWC Conical Concealed Plate (2) SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches _ Model W4 SWC-2 Note: (1) Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2) 135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers (3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1" (25mm) 1" (25mm) +/- 1/4" (6mm) 1/4" (6mm) Face of fitting to finished wall 2-5/16" ------ Top of Deflector Down a_= y from Ceiling to be Either 3 5/16" ffR�1_ (67mm) (58mm) - - - 4" to 6" (100mm to (84mm) DIA. DIA. 150mm) or 6" to 12" DIA. 5/16" (150mm to 800mm) r�, (8mm) Based on Hydraulic - Calculations 1 5/8" (41 mm) Dimensions SWC & SWC-2 Concealed Cover Plate Installation Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems('( Maximum Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance Flow gpm (I/min) Pressure psi (bar) Flow gpm (I/min) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 13 (49) 8.7 (0.60) 14 (53) 10.2 (0.7) 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.7) 14 (53) 10.2 (0.7) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) - - - - 4 to 6 inches 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) -- _ (100 to 150 mm) 16 x 18 (5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) - - - - 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) - - - - 14 x 14 (4.3 x 4.3) 15 (57) 11.7 (0.81) - - - - 15 x 15 (4.6 x 4.6) 17 (64) 15.0 (1.03) - - 6 to 12 inches (150 to 300 mm) 16 x 16 (4.9 x 4.9) 18 (68) 16.8 (1.16) -- -- 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 11 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Sidewall and Recessed Sidewall (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) �A C Material Specifications Thermal Sensor: 3 mm glass bulb 175°F (79°C) Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions 2-7/16" (62mm) 5/16" (8mm) Dimensions Face of fitting to finished wall 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) DIA. DIA. 1-5/8" (41mm) +/- 1/4" (6mm) F2 & FV Recessed Escutcheon Installation Model F1 Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 16 (61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 x 15 (4.6 x 4.6) 19 (72) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 21 (80) 13.2 (0.91) 16 x 18 (4.9 x 5.5) 25 (95) 18.6 (1.28) 16 x 20 (4.9 x 6.1) 29 (110) 25.0 (1.72) 12 x 12 (3.7 x 3.7) 22 (83) 14.4 (1.0) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 22 (83) 14.4 (1.0) 15 x 15 (4.6 x 4.6) 24 (91) 17.1 (1.18) 16 x 16 (4.9 x 4.9) 26 (98) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 31 (117) 28.6 (1.97) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliably Page 12 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Sidewall and Recessed Sidewall Sensitivity Threads: 1/2" NPT or ISO7-1 R1/2 Fast -response Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb F2 Recessed ( Sprinkler Frame: Brass Alloy FV Recessed ' I� Button: Copper Alloy Sprinkler Wrenches Sealing Assembly: Nickel Alloy with PTFE Model W2 Load Screw: Bronze Alloy Model W4 (Recessed) Deflector: Bronze Alloy Model F1 Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8" (48mm) 3/8" (10mm) +/ 1/4" (6mm) +/- 1/4" (6mm) 2-7/8" (73mm) IF/ 2-1/4" 1-15/16" Top of Deflector Down From (57mm) (49mm) - - -- Ceiling to be Either 4" to 6" DIA. DIA. (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on 5/16° Hydraulic Calculations (8mm) Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1) 30 (114) 26.8 (1.85) 4 to 6 inches (100 to 150 mm) 20 x 20 (6.1 x 6.1) 30 (114) 26.8 (1.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 52.4 (3.63) 18 x 20 (5.5 x 6.1) 35 (133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 16 x 22 (4.9 x 6.7) 38 (144) 42.9 (2.96) 16 x 24 (4.9 x 7.3) 42 (160) 52.4 (3.61) 14 x 26 (4.3 x 7.9) 46 (174) 62.9 (4.34) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliable Page 13 of 15 April 2021 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler 1 F1, F2. FV, FP(3), CCP, SWC Conical ) Sprinkler �'� F1, F2. FV, FP(3), CCP, SWC (Conical) Escutcheons Cover Plates (1) Escutcheons Cover Plates (1) Bronze Brass Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Satin Chrome Satin Chrome Satin Chrome White White White Paint Black Black Black Paint Polyester 2> Polyester Polyester (2) Polyester Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel - - PTFE (2) - Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models F1 Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: • 1/2" NPT and ISO7-1 R1/2: 8-18 ft-Ibs (11 — 24 N-m) • 3/4" NPT and ISO7-1 R3/4: 14-20 ft-Ibs (19 — 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Model W2 Model W4 Model W4 Wrench Installation Examole IF') The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model W1 wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5" (125mm) long extension (not provided) as shown in Figure 13. Bulletin 135 Reliable Page 14 of 15 April 2021 www.reliablesprinkler.com Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or IS07-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • W4 (Recessed and Concealed) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Ln m N O ti M 0) Z d Bulletin 135 ReliablE� Page 15 of 15 April 2021 www.reliablesprinkler.com Fire Pump