Loading...
APPROVED BLD2023-0886+Architectural Plans+7.15.2023_12.42.13_PM+3667757EXISTING STRUCTURE 1 I \ I � 4,_0•, N N GRAPHIC XAI.F IrFEn n 1 2 4 K 3'-6" 6" 6" OUTLINE OF DECK ABOVE f ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE I APPROVED I PLANS MUST BE ON JOB SITE I c I.................... ------------ J Hardwareand fasteners in contact with — I preservative -treated wood shall be of i hot -dipped zinc galvanized steel, I stainless steel, silicon bronze or copper. In the absence of manufacturer's 5•_6•• I recommendations a minimum of ASTM A 653 type G185 zinc -coated galvanized steel, or I R>• I equivalent, shall be used. IRC 11317.3.1 IBC 2304.10.5.1 l_._._._._._._._._._.. FOUNDATION PLAN SCALE: 1/4" = V-0" NOTES: VERIFY FOOTING DEPTH MEETS or EXCEEDS LOCAL CODES FOR FROST. ENGINEER CALCULATES MINIMUM DEPTH = 24" • VERIFY MINIMUM SOIL BEARING >_ 1500 PSF • ALL FOOTINGS SHALL BE NEW CONSTRUCTION (UNO). • STAIRS OPTIONAL. STAIRS SHALL HAVE A CLEAR AREA LANDING AT BOTTOM AS WIDE AS THE STAIR & 36" MIN. IN DIRECTION OF TRAVEL. City Of Edmonds Building Department ___________________________ Works DECK Address 22014 92ND AVE W L- _MATHIEU ---____-_-_ Owner�_ Approved Dates 08/16/2623 _ _ _ _ _ _ _ _ _ _ _ _ Building Official' Erit, C._A_H_'(YX I - - - - Permit NumberBLD2023-0886 9% A0000Tk Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P:919.844.6050 extI E: decks(Pdansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MOM �./0 W W 5CZ CZ cV ''�o r" C;\ ?oi V' 0O U N w CODES, DESIGN LOADS, BASIC WIND, AND SNOW LOAD: DCSI'E a: 23-D-036 WA: 2018 INTERNATIONAL RESIDENTIAL CODE w/ WASHINGTON AMENDMENTS. Drawn By: ACS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER Revision History: STRUCTURES, ASCE 7-10 (UNLESS ASCE 7-05 or 7-16 SPECIFIED PER CODE). X For Construction LIVE LOAD: 60 PSF DEAD LOAD: 10 PSF _ Not for Construction DL+LL: 70 PSF BASIC WIND SPEED: 110 MPH Sheet SNOW LOAD (g): UP TO 40 PSF S-1 of 16 "A 18'-0" FRAMING INFO: n A t POSTS ARE TO BE: 4.6 PT - St L- except: 6x6 PT @ SPLICES EXISTING STRUCTURE 'FLOOR JOISTS TO BE: 2x10 PT @ 16" O.C. LEDGER TO BE: 2x10 PT LEDGER 4 BEAMS TO BE: (2) 2x10 PT DROPPED in 1L USP JUS210-2TZ GIRDER (TYP UNO) DOUBLE HANGER (I'YP UNO) II II FLOOR JOIST HANGERS TO BE: 11 O 11 Ill II II II @ RIM JOISTS: 2x12 PT STAIR BOARD NEXT USP JL210IF-TZ INVERTED USP CSH-TZ STRINGER 3 TO 2x10 PT @ STAIRS (TYP) FLANGE (TYP UNO) HANGER (TYP) 2x12 STAIR STRINGER ❑ @ ALL OTHER JOISTS USP JL210-TZ HANGER (TYP O.C. @ 9" O(UNO PER N-2) ❑ a O UNO) ADD HANDRAILS' U (511EF.T W-6) and/or POSTS 11 IMI k ON SIDES OF STEPS 4'-0" NOTES: 13'-0" FRAMING PLAN SCALE:1/4" =1'-0" GUARDRAIL POST - SEE SHEET (C-7, T-7o, or T-7c) (T YP) PICKET SHEET W-6 (TY ) 200 PT BAND BOARD (TYP UNO) USP RT7A-TZ PER DETAIL 1/I'-1C (I-YP) • FRAMING MATERIAL (UNO): PT SYP x2 • GRADE to TOP OF DECKING MAX. DECK HEIGHT. 9'-2" • IT IS ACCEPTABLE TO USE LUMBER LARGER THAN SPECIFICATION. • POSITION ALL GIRDER SPLICES OVER 6x6 POST. ALL POSTS SHALL BE CONTINUOUS U.N.O. • IF USING COMPOSITE DECK MATERIALS, SEE SHEET N-2 FOR SPACING ADJUSTMENTS. • GUARDRAILS REQUIRED FOR DECKS 230" ABOVE GRADE. • ACCEPTABLE TO MAKE OUTER BAND BOARD FLUSH w/ TOP OF DECKING, PER HOMEOWNER REQUEST. • NOT SHOWN - AESTHETIC FASCIA FINISH OPTIONAL & PER HOMEOWNER ORDER. • NO DEVIATIONS FROM THESE "SER" SEALED PLANS WITHOUT PRIOR WRITTEN APPROVAL. • ONLY THE MOST RECENT SEALED PLANS ARE VALID; GC SHALL FOLLOW REVISION SPECIFICATION. GRAPHIC SCALE(FEM 0 1 2 3 4 99� *00 Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decks@dansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: S-2 of 16 Stairs to have a grippable handrail on at least one side. 5'4" 13'-0" I FRONT DECK SKETCH SCALE: 1/4" = V-0" ELEVATION VIEW NOTES: • ELEVATIONS ARE ILLUSTRATIONS BASED ON DATA PROVIDED. INSTALLER SHALL VERIFY ACTUAL SITE CONDITIONS. • RAILINGS & PICKETS DESIGN MAY VARY PER HOMEOWNER REQUEST. REFER TO DETAIL SHEETS FOR ALLOWABLE DESIGNS. jC 9'-2" MAX. DECK HT 99: Om Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decksvdansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE +: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: E-1 of 16 DESIGN LOADS: GENERAL NOTES: 1. BUILDING CODES 1. IMPORTANT. CONTRACTOR IS TO READ ALL NOTES AND REVIEW ALL dIAE03 DETAILS PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR Daniel C. Smith, PE 1.1 WA: 2018 INTERNATIONAL RESIDENTIAL CODE w/ WASHINGTON RESPONSIBLE FOR VERIFYING LOCAL FROST DEPTH AND VERIFYING THAT Consulting Engineer AMENDMENTS. THE FOOTING DEPTH NOTED ON THE DRAWINGS ARE ADEQUATE. IF LOCAL 5068 Isabella Cannon Dr 1.2 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER FROST DEPTH IS MORE SHALLOW THAN WHAT IS SPECIFIED ON THE Raleigh, NC 27612 STRUCTURES, ASCE 7-10 (UNLESS ASCE 7-05 or 7-16 SPECIFIED PER DRAWINGS, CONTRACTOR TO GO BY DEPTH ON DRAWINGS. CODE). P: 919.844.6050 ext 1 2. THE DESIGN PROFESSIONAL WHOSE SEAL APPEARS ON THESE DRAWINGS IS E: decksadansmith e.com 2. DESIGN CRITERIA THE STRUCTURAL ENGINEER OF RECORD ("SER") FOR THIS PROJECT. NO RESIDENTIAL OTHER PARTY MAY REVISE, ALTER, OR DELETE ANY STRUCTURAL ASPECTS 2.1 UNLESS OTHERWISE NOTED ON SHEET S-2 (aka LARGE LOADS on OF THESE CONSTRUCTION DOCUMENTS WITHOUT WRITTEN PERMISSION OF FRAMING PLAN), NO HOT TUBS, SPAS, SAUNAS, BRICK/MASONRY DANIEL C. SMITH PE CONSULTING ENGINEER AND THE "SER". ATTACHED FIRE PLACES, BARBECUE PITS, ETC., ARE TO BE SUPPORTED ON THE DECK DECK STRUCTURE. 3. "SER" IS NOT RESPONSIBLE FOR CONSTRUCTION SEQUENCES, METHODS, OR TECHNIQUES IN CONNECTION WITH THE CONSTRUCTION OF THIS 2.2 LIVE LOAD: 60 PSF STRUCTURE. "SER" WILL NOT BE HELD RESPONSIBLE FOR THE 2.3 DEAD LOAD: 10 PSF CONTRACTOR'S FAILURE TO CONFORM TO THE CONTRACT DOCUMENTS, 2.4 DL+LL: 70 PSF SHOULD ANY NON -CONFORMITIES OCCUR. 2.5 BASIC WIND SPEED: 110 MPH 2.6 SNOW LOAD (g): UP TO 40 PSF 4. VERIFICATION OF ASSUMED FIELD CONDITIONS IS NOT THE RESPONSIBILITY 2.7 EXPOSURE C OF "SER". CONTRACTOR SHALL VERIFY THE FIELD CONDITIONS FOR RECEIVED 2.8 WIND IMP. FACTOR 0.87 (ASCE 7-05) ACCURACY BEFORE CONSTRUCTION BEGINS. RISK CATEGORY I (ASCE 7-10) Jul 26 2023 OFEDMONDS 2.7 CHECKED LOAD FOR COMBINATIONS: DL + WL (75%) 5. THIS STRUCTURE AND ALL CONSTRUCTION SHALL CONFORM TO ALL DEVELOPMENT SERVICES 2.8 CHECKED LOAD FOR COMBINATIONS: DL - WL (UPLIFT) APPLICABLE SECTIONS OF THE INTERNATIONAL RESIDENTIAL CODE AND DEPARTMENT ANY LOCAL LAWS WHERE THE STRUCTURE IS TO BE CONSTRUCTED. 3. DESIGN NOTES 3.1 WHERE THE SNOW LOAD (g), DETERMINED BY LOCAL ENFORCEMENT AGENCY, EXCEEDS 40 PSF, DECK HAS BEEN DESIGNED TO ACCOUNT FOR INCREASED LOADS. TERMINOLOGY SYMBOLS GIRDER aka BEAM 0 DIAMETER BAND BOARD aka RIM JOIST or 'W DETAIL NUMBER SKIRT BOARD or "s" SHEET NUMBER RIM PLATE RIM JOIST OUTER -MOST JOIST or /C CROSS BRACING JOIST w/ RIM TRACK ABBREVIATIONS APPROX. APPROXIMATELY EQUIV. EQUIVALENT FJ FLOOR JOIST FTC FOOTING GALV. GALVANIZED H.D. HOT DIPPED HDG HOT DIPPED GALVANIZED OPT. OPTIONAL PT PRESSURE TREATED R.S RING SHANK SIM. SIMILAR S.S. STAINLESS STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE V.I.F. VERIFY IN FIELD 6. NO DECK ATTACHMENT ALLOWED TO HOUSE BAND ON SECOND FLOOR, or HIGHER, THAT IS ON A CANTILEVERED OVERHANG. 0 N 7. INSTALL EITHER GALVANIZED OR VINYL FLASHING BETWEEN THE DECK C) AND HOUSE PER CODE REQUIREMENTS. OD 8. STAIRWAYS SHALL HAVE A NEW OR EXISTING LIGHT SOURCE LOCATED IN r+ � THE IMMEDIATE VICINITY OF THE TOP OF EXTERIOR STAIRS. LIGHT SHALL OPERATE EITHER WITH CONTINUOUS ILLUMINATION, BY AUTOMATIC +�+ `fit CONTROL (E.G., MOTION DETECTION), OR WITH A SWITCH INSIDE THE DWELLING. [2012 IRC R303.7 or EQUIVALENT CODE PER STATE] 9. ALL SECTIONS AND DETAILS ARE TYPICAL AT SIMILAR LOCATIONS AND WHERE APPLICABLE. DETAILS APPLY ONLY TO EXACT CONDITIONS f-1 SHOWN. DETAILS ARE NOT TO BE MODIFIED FOR SIMILAR CONDITIONS, O EXCEPT DETAILS MAY BE MIRRORED TO MATCH FIELD CONDITIONS. 10. DANIEL C. SMITH PE CONSULTING ENGINEER AND THE "SER" ASSUME NO O LIABILITY FOR DETAILS ADAPTED TO SIMILAR CONDITIONS. U (V w 11. DANIEL C. SMITH PE CONSULTING ENGINEER AND THE "SER" ASSUME NO LIABILITY FOR WATER TIGHT INTEGRITY. CONTRACTOR SHALL PROVIDE DCSPE ✓<: 23 D-036 FLASHING TO ADJACENT STRUCTURES PER ACCEPTED PRACTICE AND Drawn By: ACS METHODS. Revision History: 12. OWNER/CONTRACTOR TO CONFIRM DECK DESIGN DOES NOT INTERFERE X For Construction WITH EGRESS PATHWAYS, ELECTRICAL CLEARANCES, WINDOW GLAZING, ETC. or SHALL MAKE MODIFICATIONS TO EXISTING STRUCTURES AS Not for Construction APPROPRIATE TO MEET LOCAL CODE. She�eTt 13. THESE PLANS ARE VALID FOR PERMITTING WITHIN 12 MONTHS OF THE SEAL DATE. -1 1 V of 16 FOOTINGS & CONCRETE 1. WARNING: IDENTIFY UNDERGROUND UTILITIES BEFORE DIGGING. OWNER/CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER IF DIFFERENT. 2. FOOTINGS SHALL BE PLACED ON FIRM NATURAL OR COMPACTED FILL. FOOTINGS MUST BE SET ON NON -FROST SUSCEPTIBLE SOILS. THE FOUNDATION IS BASED UPON AN ASSUMED NET SOIL BEARING CAPACITY OF 1500 PSF. 3. FOOTING DEPTH SHALL BE AS SPECIFIED ON FOOTING DETAILS. 4. NO CONCRETE SHALL BE POURED ON TOP OF or NEXT TO ANY SUB -GRADE CONTAINING WATER, ICE, FROST, OR LOOSE MATERIAL. CONCRETE SHALL HAVE NORMAL WEIGHT AGGREGATE AND A MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS OF 3000 PSI. 6. CONCRETE TO CURE (3) DAYS MINIMUM PRIOR TO BEGINNING CONSTRUCTION OF DECK. STAIR TREAD MATERIAL 1. STAIR STRINGERS SPACED >12" O.C. SHALL ALWAYS USE DIMENSIONAL LUMBER FOR TREADS. 2. IF COMPOSITE TREADS ARE TO BE INSTALLED, NOW or IN THE FUTURE, THEN STRINGERS SHALL BE 12" O.C. MAXIMUM (UNO BY COMPOSITE MANUFACTURER). STAIR FRAMING MAY REQUIRE MODIFICATION IF CHANGING FROM DIMENSIONAL LUMBER TO COMPOSITE TREAD MATERIAL. Wn nD FRAMING COMPOSITE DECKING (TREX, CHOICEDEK or SIMILAR): 1. READ AND FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. REDUCE JOIST SPACING AS/IF REQUIRED. 2. COMPOSITE DECKING CANNOT BE USED FOR STRUCTURAL APPLICATIONS. USE SPECIFIED STRUCTURAL MATERIAL FOR FRAMING AND JOISTS. INSTALL JOIST LUMBER PER MANUFACTURER'S SPACING RECOMMENDATIONS. 3. PROVIDE GAP BETWEEN COMPOSITE DECKING BOARDS AS SPECIFIED BY MANUFACTURER FOR AIRFLOW. 4. USE #7 x 2Y4" S.S. TRIM HEAD or #8 x 2,Vi' PRIMEGUARD TEN® SCREWS, or SCREWS AS SPECIFIED BY COMPOSITE MANUFACTURER TO FASTEN ONLY DECK BOARDS. 5. FOR FACE ATTACHMENT, FASTEN DECK BOARDS w/ (2) FASTENERS PER JOIST. ALIGN BUTT ENDS OVER MIDDLE OF JOIST AND PRE -DRILL ANGLED HOLE INTO JOIST. ALTERNATIVELY, SISTER 2x4 NAILER BOARD TO JOIST UNDER BUTT JOINT w/ (2) GRIP -RITE #9 x 3" HDG NAILS AND INSTALL DECK BOARD FASTENERS @ 90' ANGLE INTO 2x4 NAILER. 6. FOR CONCEALED ATTACHMENT, VERIFY METHOD APPROVED FOR PROJECT APPLICATION (e.g., SEISMIC LOCATION). USE NUMBER AND LOCATION OF START CLIPS AND CONNECTOR CLIPS AS SPECIFIED BY MANUFACTURER. 7. STAIRS TREADS CONSTRUCTED OF COMPOSITE MATERIALS REQUIRE STRINGERS SPACED 12" O.C. MAXIMUM (UNO BY MANUFACTURER). STRINGERS SHALL BE 9" O.C. WHEN USING TREX BRASILIA, CONTOURS, AND ESCAPES DECKING (UNO BY MANUFACTURER). 8. ATTACHMENTOF COMPOSITE POSTS AND RAILINGS VARY WITH STYLE AND MANUFACTURER. FOLLOW MANUFACTURER INSTRUCTIONS CAREFULLY. 1. SOLID SAWN WOOD FRAMING SHALL CONFORM TO THE SPECIFICATIONS AS LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" LATEST EDITION (NDS). THE FRAMING SHALL BE OF THE SPECIES AND GRADE AS SPECIFIED. 2. ALL LUMBER SHALL BE "PRESSURE" OR "PLUS PRESSURE" TREATED LUMBER OR EQUIVALENT 3. PRESERVATIVE RETENTION OF ALL FRAMING MEMBERS SHALL BE AS LISTED BELOW: 3.1 ABOVE GROUND: .25 LBS/CU. FT 3.2 GROUND CONTACT: .40 LBS/CU. FT 4. GIRDERS or OTHER FRAMING CONTAINING MULTIPLE PLIES OF LUMBER SHALL HAVE EACH PLY ATTACHED TO THE ADJACENT PLY w/ (3) GRIP -RITE #9 x 3" HDG NAILS V 12" O.C. 5. UNTREATED POST, PRIMED & PAINTED w/ COAL TAR EPDXY FOR CONTACT WITH GROUND MAY BE SUBSTITUTED FOR PRESSURE TREATED POST. 6. SOME REGIONS REQUIRE A FIRE TREATED LEDGER BOARD FOR ATTACHED DECK. GC TO CHECK LOCAL REGULATIONS. 7. APPLY IN -FIELD PRESERVATIVE TREATMENT TO CUT ENDS OF ALL PRESSURE TREATED LUMBER. ,go; 88S Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: deckseodansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: N-2 of 16 FASTENER NOTES 1. ALL CONNECTORS SHALL BE APPROVED FOR USE WITH ACQ (or EQUIVALENT) PRESSURE TREATED LUMBER. 2. BOLTS, NUTS & WASHERS SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 CLASS D. INSTALL BOLTS 2" MINIMUM FROM END. BOLT HOLES SHALL BE Y16' MAXIMUM LARGER THAN BOLT DIAMETER. 3. LAG SCREWS SHALL BE HOT DIPPED GALVANIZED, AND CONFORM TO ANSI/ASME STANDARD B18.2.1-1981. HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 70% OF THE SHANK DIAMETER, AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. DO NOT INSTALL THREADED PORTION OF SCREW BY DRIVING WTIT-I A HAMMER. 4. ALL NAILS AND SCREWS IN CORROSIVE ENVIRONMENTS (e.g., WITHIN 2 M1LES OF SALT WATER) SHALL BE STAINLESS STEEL. SEE SUBSTITUTION SCHEDULE. 5. ALL NAILS SHALL BE HOT -DIPPED GALVANIZED PER ASTM A153 (UNO). HANGER NAILS SHALL PENETRATE WOOD 1Y2" MINIMUM. 6. ALL SCREWS SHALL BE HOT -DIPPED GALVANIZED PER ASTM A153 (UNO). 7. LAG SCREWS (e.g., LedgerLOKp) ARE NOT ALLOWABLE SUBSTITUTIONS FOR BOLTS PER CODE (TYP). CORROSIVE ENVIRONMENT FASTENERS IN CORROSIVE AREAS, USE THE FOLLOWING SUBSTITUTION FOR FASTENER INDICATED IN DETAILS. DETAIL SPECIFIES - SUBSTITUTE - GRIP -RITE #9 x 1Y2" HDG NAILS GRIP -RITE #13 x 2" S. S. NAILS GRIP -RITE #9 x 3" HDG NAILS GRIP -RITE #13 x 2" S. S. NAILS GRIP -RITE #9 x 3Y4" HDG NAILS GRIP -RITE #8 x 3Y2" S. S. NAILS GRIP -RITE #10 x 4" HDG SCREWS GRIP -RITE 910 x 3" S. S. SCREWS CONNECTORS & EQUIVALENTS (USE SIZE SPECIFIED IN PLANS or LARGER) SYMBOL PURPOSE USP# SIMPSON SUBSTITUTION STRAP to secure GIRDER/FJ to FOOTING ST1-TZ MAB15Z 4x4 POST BASE PA44E-TZ, PAU44-T7_ ABA44Z, AB44Z ® 4x6 POST BASE PA46E-TZ, PAU46-TZ ABA46Z, ABU46Z ® 6x6 POST BASE PA66E-T7, PAU66-TZ ABA66Z, ABU66Z p POST CAP for FLUSH GIRDER PB44-6T7, PB66-6TZ L.PC4Z, LPC6Z s RAFTER TIE used to secure FJ to GIRDER RT7A-TZ H2.5AZ J L U 1-PLY HANGER NS26-TZ, JUS28-TZ, JUS210-TZ LUS26Z, LUS28Z, LUS21OZ J L p sJ u {� y 2-PLY HANGER JUS26-2TZ, JUS28-2TZ, JUS210-2TZSC LUS26-2Z, LUS28-2Z, LUS210-2Z LJ 1-PLY INVERTED FLANGE HANGER JL26IF-TZ, JL210IF-TZ LUC26Z, LUC21OZ LU ® 2-PLY INVERTED FLANGE HANGER (2) JL26IF-TZ, (2) JL210IF-TZ HUC28-2Z, HUC210-2Z 1 ` 1-PLY ADJUSTABLE SKEWED JST HANGER LSSH15-TZ LSU26Z i ADJUSTABLE L-ANGLE MP5-TZ, MP7-TZ, MP9-TZ LS50Z, LS70Z, LS90Z U l ADJUSTABLE STAIR STRINGER HANGER CSH-TZ LSCZ a FRAMING ANGLE for BLOCKING REINFORCEMENT A3-TZ GA2 DECK TIE BACK w/ THREADED ROD & (8) SCREWS DTB-TZ D= TENSION TIE for LEDGER REINFORCEMENT LTS19-77. I = O D �� Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decksudansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet : N-3 of 16 PT POST PER PLAN OPTIONAL: USE 6" LONG x 12" 0 SONATUBE TO FORM CONCRETE ABOVE GRADE. TOP SQUARE or ROUNDED EDGE PER GC SOIL GRADE SHALL BE HORIZONTAL FOR 2 FEET 2 MINIMUM AROUND POST ° ON ALL SIDES CONCRETE SHALL HAVE NORMAL WEIGHT AGGREGATE AND A MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS OF 3000 PSI. NOTE: INSTALLER MUST VERIFY LOCAL FROST DEPTH. USE THE GREATER OF DEPTH SPECIFIED HERE & LOCAL FROST DEPTH. USP STANDOFF POST BASE AS SPECIFIED or EQUIVALENT FOR POST SIZE: 4x4 PA44E-TZ 4x6 PA46E-TZ 6x6 PA66E-TZ Y2" 0 ANCHOR BOLT w/ WASHER & NUT - 7" EMBEDMENT — _ °Q as - I I 1 11 - i=MIT— =1 I I=1 I =1 1= (MIN.) ° . 111 .I I MI I POURED CONCRETE °° IN DRILLED or DUG —I — _ ..•. .. . . = HOLE I—) —III— °.. `.� .�.°°.:.`:a'. �.°• .:•I— I— II 1I— II —I I— I a II I I-1 1- _ I I— ° •° ° •� ° a°: ' -_ VERIFY MIN. SOIL = I (—_III — I BEARING >_ 1500 PSF — I= 12 QJ - 12" O CONCRETE to DEPTH SCALE: 2" =1'-0" ELEVATION VIEW GRAPHIC SCALE (INCHES) 0 3 6 9 12 Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: deckscodansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 9 DCSPr. a: 23-D-036 Drawn By: ACS Revision History: X for Construction Not for Construction Sheet: F-4 of 16 PT POST PER PLAN OPTIONAL: USE 6" LONG x 12" 0 SONATUBE TO FORM CONCRETE ABOVE GRADE. TOP SQUARE or ROUNDED EDGE PER GC SOIL GRADE SHALL BE HORIZONTAL FOR 2 FEET Z MINIMUM AROUND POST 7 >� ON ALL SIDES CONCRETE SHALL HAVE NORMAL WEIGHT AGGREGATE AND A MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS OF 3000 PSI. NOTE: INSTALLER MUST VERIFY LOCAL FROST DEPTH. USE THE GREATER OF DEPTH SPECIFIED HERE & LOCAL FROST DEPTH. USP STANDOFF POST BASE AS SPECIFIED or EQUIVALENT FOR POST SIZE: 4x4 PA44E-TZ 4x6 PA46E-TZ 6x6 PA66E-TZ %" 0 ANCHOR BOLT w/ WASHER & NUT - T' EMBEDMENT °. d o _-I I 11 s a..••d ro•.• -•- •e•• ° DEPTH - I ° :. : d . (MIN.) = I I=I I Ed I = 1= I 4. —I I ER I I_ ° • °a ..° °d A I I 1 I I ° I I =POURED CONCRETE = =I I IN DRILLED or DUG o4. .° ° •,a °.• °... a -- -I I— d..d -Fla I 1=1 I —HOLE d'.. d• VERIFY MIN. SOIL IIiii j I I I=III=16I g I I I=III=I = BEARING>_ 1500PSF I_� I (OPT. SUBSTITUTION 16" x 16") - I 16" 0 CONCRETE to DEPTH SCALE: 2" = V-0" ELEVATION VIEW GRAPHIC SCALE (INCHES) 0 3 6 9 12 199; B Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decks®dansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE -1: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: F-5 of 16 EXISTING HOUSE WRAP #1- CUT EXISTING HOUSE WRAP & INSTALL FLASHING FULL DEPTH OF LEDGER BEHIND HOUSE WRAP #2- INSTALL FLEXIBLE TOP FLASHING UNDER HOUSE WRAP; #4- FOLD OVER TOP OF LEDGER #3- INSTALL NEW LEDGER PER SHEET T-3 NOTE: USE FLEXIBLE THERMOPLASTIC or SEALING PVC FLASHING 16"-18" WIDE. END LAP MINIMUM 6" AS NEEDED. F SIDING EXTERIOR FLASHING L-SI SCALE: 1" =1'-0" ELEVATION VIEW REMOVE EXISTING SIDING BETWEEN LEDGER & BAND BOARDS REMOVE EXISTING WALL SHEATHING BETWEEN BOARDS — IF NOT PLYWOOD OR OSB FLASHING PER SEE FRAMING PLAN FOR DETAIL F/L-St ORIENTATION & SPECIFICATION DECKING FLOOR JOIST N C EXISTING HOUSE BAND BOARD INSTALL WOOD BLOCKING MATCHING HOUSE FJ DEPTH w/ (2) GRIP -RITE #9 x 3" HDG TOE -NAILS PER END r-- EXISTING HOUSE FLOOR JOIST EXISTING HOUSE BAND BOARD EXISTING HOUSE FLOOR JOIST PERPENDICULAR TO BAND PT LEDGER PER PLAN w/ FASTENERS EXLSM o NOTE: TENSION TIE DEVICE PER INCLUDED SHEET T-3 woo w/ 750 LBS MIN. CAPACTIY @ FRAM D (4) LOCATIONS w/ (1) WITHIN USP LTS19-TZ w/ (1) %g" LAG BOLT FOUNDA ION & (2) WASHERS & (8) #9 x 3" HDG (BYon RS) 24" OF EACH END. NAILS LOCATED PER PLAN A LEDGER on SIDING EXTERIOR w/ TENSION TIE S GRAPHIC SCALE (INCHES) �} L-St SCALE: 1" =1'-0" ELEVATION VIEW D 3b1 ,: 99 ❑❑D ❑❑❑ Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: deckscodansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: L-St of 16 FASTENER NOTE: USE GRIP -RITE #9 x 1%2" HDG NAILS FOR ALL HARDWARE (UNO). GRAPHIC SCALE (INCHES) 0 3 6 9 12 FLOOR JOIST PER PLAN PT BLOCKING PER 2/T-1C TOE -NAILS PER 2/T-1C TOE -NAIL (2) GRIP -RITE #9 x 3" HDG NAILS PER JOIST/GIRDER INTERSECTION (TYP) PT BLOCK MATCHING FJ DEPTH w/ — (2) GRIP -RITE #9 x 3" HDG NAILS PER END (TYP) IRDER — —_ �IP — — — I 1 FREQUENCY OF GIRDER CLIP/NAILS T-1 SCALE: 3/4" = V-0" PLAN VIEW FLOOR JOIST — — PER PLAN DROPPED GIRDER PER PLAN USP RT7A-TZ GIRDER CLIP PER DETAIL 3/T-1C 2 GIRDER CLIP & NAIL CONNECTIONS T-1 SCALE: 1-1/2" = V-0" ELEVATION VIEW FLOOR JOIST PER PLAN USP RT7A-TZ ON A MINIMUM OF EVERY 3rd JOIST w/ (4) CLIPS DROPPED GIRDER MINIMUM PER DECK - TYP PER PLAN (SEE FASTENER NOTE) 3 JOIST to GIRDER CLIP T-1 SCALE: 1-1/2" =1'-0" ELEVATION VIEW ,,Ark Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decksuclansmithpe.com RESIDENTIAL ATTACHED DECK er® n.wuc mnL �s uvxEnucwa.vx RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O N 00 v v � c� O UNw DCSPE r: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: T-1C of 16 FASTENER NOTE: USE GRIP -RITE #9 x IY2" HDG NAILS FOR ALL HARDWARE (UNO). GRAPHIC SCALE (INCHES) 0 3 6 9 12 DECKING & FJ (A) BACK VIEW cV 1) 1/2" 0 x 6" HDG BOLTS w/ VASHER & NUT NOTCHED 4x6 or 6x6 PT POST PER PLAN FLOOR JOIST PER PLAN (B) SIDE VIEW 1 NOTCHED POST for DROPPED GIRDER T-1D SCALE: 1-1/2" =1'-0" ELEVATION VIEW ILM DECKING PER HOMEOWNER, Y4 x 6 or EQUIVALENT, WOOD or COMPOSITE w/ #7 x 2Y4" S.S. TRIM HEAD or #8 x 2%2 PRIMEGUARD TEN® SCREWS or SCREWS AS SPECIFIED B) COMPOSITE MANUFACTURER (TYP FLOOR JOIST PER PLAN - SEE DETAIL 2/T-1C FOR ATTACHMENT 1 Y4„ 1 Y4„ °•i N I I i LJ u0 I i 2x8 MIN. PT 1 DROPPED �r I GIRDER cv I PER PLAN (2)Y2"0x6" 5Y2 HDG BOLTS PER GIRDER (TYP) 6x6 PT POST FRONT VIEW 2 DROPPED GIRDER SPLICE T-1D SCALE: 1-1/2" =1'4' ELEVATION VIEW USP HANGER PER PLAN JSTALL PSIDE-DOWN EE FASTENER NOTE) DECK BAND BOARD PER PLAN CANTILEVERED FLOOR JOIST PER PLAN 3 HANGER for CANTILEVERED FJ T-1D SCALE: 1-1/2" =1'-0" ELEVATION VIEW 199 Daniel C. Smith, PE Considting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decksudansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE 9: 23-D-036 Drawn By: ACS Revision History: _2L For Construction Not for Construction Sheet: T-1D of 16 (3) GRIP -RITE SCREWS (3) GRIP -RITE SCREWS (3) GRIP -RITE SCREWS 2x6 PT CROSS BRACING GIRDER PER PLAN NEAREST FLOOR JOIST TO POST 2x6 PT CROSS BRACING (CAN BE ON EITHER SIDE OF POST) PT BLOCKING 'A' (SEE NOTES) DROPPED GIRDER CROSS BRACING IT2D SCALE:1" =1'-0" PLAN VIEW GRAP111C SCALE ONCHESI U 6 9 ., S1 A / If Q w z W Q w W NOTES: • FASTEN w/ (3) GRIP -RITE #10 x 4" HDG SCREWS (TYP UNO). • LOCATE SCREWS AT LEAST 2" FROM EDGES OF FRAMING MEMBERS. • INSTALL 8' LONG PT BLOCKING 'A' ONLY WHEN EDGE OF POST IS GREATER THAN 3" AWAY FROM NEAREST FLOOR JOIST. FASTEN w/ (3) GRIP -RITE SCREWS. • PT CROSS BRACING SHALL BE ANGLED 40' to 50°. 8" LONG PT BLOCKING 'A' (SEE NOTES) DECKING ---\ FJ PER PLAN GIRDER PER PLAN 40° to 50° O ((yP) o 2x6 PT CROSS BRACE (TYP) (3) GRIP -RITE SCREWS POST PER PLAN 2 DROPPED GIRDER CROSS BRACING T-2D SCALE: =1'-0" ELEVATION VIEW 1995;t�� Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon or Raleigh, NC 27612 P: 919.844.6050 ext 1 E: deckscodansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: T-2D of 16 PT LEDGER PER PLAN %" 0 (UNO) HDG HEX THRU-BOLTS w/ WASHER & NUT @ 16" O.C. STAGGERED iV 16" O.C. NOTES: • NO LedgerLOKV or EQUIVALENT SCREWS ALLOWED. GP.A1711C SCA1P.11NC I i s n ! 6 EXISTING HOUSE BAND BOARD REFER TO LEDGER SECTION (3) DETAIL FOR FINISH & SHEATHING SPECIFICATION NEW LEDGER HDG THRU-BOLT w/ • WASHER & NUT (TYP) . z SECTION X N � 4" L X ' IMAX. 1 • LAG BOLTS (or SUBSTITUTION LAG SCREWS) CANNOT BE SECURED TO PLYWOOD or OSB ONLY. • NORTH CAROLINA REQUIRES %" 0 HDG BOLTS PLUS (3) GRIP -RITE #9 x 3%" HDG NAILS @ 6" O.C. PT LEDGER PER PLAN %" 0 (UNO) x 6" HDG LAG BOLTS BOTH w/ WASHER @ 16" O.C. REQUIRED GRIP -RITE #10 x 4" HDG SCREWS @ 8" O.C. STAGGERED C4 e 16" O.C. a _I • R 1 TYP LEDGER to HOUSE BAND BOARD T-3 SCALE: 1" =1'-0" ELEVATION VIEW EXISTING HOUSE BAND BOARD REQUIRED TO REMOVE FINISH & SHEATHING BETWEEN BOARDS NEW LEDGER DIRECTLY =L ON BAND BOARD HDG LAG BOLT w/ WASHER SCREW (TYP) SECTION NOTES: IF ACCESS TO BAND BOARD IS NOT AVAILABLE (e.g., FINISHED BASEMENT CEILING, ETC.), THEN THE CONTRACTOR MUST DETERMINE IF LAG SCREWS CAN FASTEN INTO SOLID LUMBER. REMOVE PLYWOOD SHEATHING AND VERIFY FRAMING SYSTEM TYPE (i.e., TRUSS or DIMENSIONAL LUMBER), SPACING & DIRECTION. NOT ALLOWED TO LAG TO ONLY OSB, PLWOOD, or BLACK BOARD BECAUSE NOT STRUCTURALLY ADEQUATE. HOUSE BAND BOARD w/ FINISHED CEILING SCALE: 1" =1'-0" ELEVATION VIEW ED e ED E Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 91 9.844.6050 ext1 E: decksodansmithoe.com RESIDENTIAL ATTACHED DECK c sm DA.mcnunCnsanxsnw:,, RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2I DCSPE k: 23-D-036 Drawn By: ACS Revision History: _?L For Construction Not for Construction Sheet: T-3 of 16 I -PLY BAND w/ BLOCKING 4x4 PT GUARDRAIL POST _ @ G-0" O.C. MAX. (TYP) DECKING w/ MIN. (10) SCREWS WITHIN 12" 0 OF POST (TYP) BAND BOARD PER PLAN (TYP) (2) %" 0 x 8" HDG BOLTS (TYP) '-OCKING PER rLAN BELOW (TYI-) GRAPHIC SCALE 1INCHUS) D 1 6 9 13 WARNING: DO NOT NOTCH 4x4 PT GUARDRAIL POSTS. 2-PLY BAND BOARD or GIRDER PER PLAN (TYP) NOTES: • GUARDRAIL POSTS DESIGNED FOR 200 LBS POINT LOAD. • BOLTS SHALL BE THRU CENTERLINE OF 2-PLY BAND/GIRDER POST & AT LEAST 2" FROM EDGES. INSIDE GUARDRAIL POST CONNECTION SCALE: 1" = V-0" ELEVATION VIEW FIBERON or TREX NOTES: • DO NOT USE POST MOUNT SCREWED THRU TOP OF DECKING. a • INSTALL GUARDRAIL POSTS C., PER SHEET T-7 DETAILS. • FINISH GUARDRAIL w/ FIBERON or TREX POST SLEEVE PER MANUFACTURER. LEGEND: B PT BLOCKING - MATCH FJ SIZE FJ FLOOR JOIST BIG BAND BOARD or GIRDER DECK SCREW a EQUAL • USE (2) GRIP -RITE #9 x 3" HDG NAILS PER END TO FASTEN BLOCKING USING TOP&BOTTOM or FACE TOE -NAILS. • BOLTS HAVE OPTION TO BE COUNTER SUNK MIN. —INTO THE BOARD FOR FLUSH FACE FINISH. PERPENDICULAR MID -BAY 2-PLY ERPENDICULAR PERPENDICULAR PARALLEL I -PLY CORNER I -PLY MID -BAY I -PLY 2 EXAMPLE LOCATIONS - INSIDE T-7 SCALE:1" =1'-0" PLAN VIEWS 19%; � Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.944.6050 ext 1 E: decks@dansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W, 0000 � v � Cz a U c�1 W DCSPE #: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: T-7 of 16 GRAPHIC SCAII. (!NO ILS) D T 6 9 12 TRIM BACK EDGE OF STRINGER AS SHOWN USP CSH-TZ CONCEALED STRINGER HANGER w/ GRIP -RITE #9 x 1%" HDG NAILS FLOOR JOIST, BAND or OUTSIDE GIRDER BOARD PER PLAN (N.T.S.) 2x12 PT STAIR BOARD w/ (3) GRIP -RITE #9 x 3" HDG NAILS @ 12" O.C. PT STRINGER 1 DROPPED STRINGER TOP CONNECTION W-3 SCALE: 1" =1'-0" ELEVATION VIEW STAIR STRINGER 4x4 PT GUARDRAIL POST EITHER INSIDE or OUTSIDE OF STRINGER (2�P, O x 6" HDG BOLTS 4"N GUARDRAIL POST TO STRINGER SCALE: l" - 1'-0" PLAN VIEW NOTE: POST NEEDED EVERY 8'-0" MAX. OF STAIR RUN (2)%Z'0x6"HDG BOLTS (TYP)_�r N PT STRINGER BEVEL -CUT 2x8 PT 1 w/ (4) GRIP -RITE #10x4"HDG t N SCREWS PER POST 4x4 PT POST (EITHER INSIDE or OUTSIDE STRINGER) SEE 12" 0 FTG PER PLAN GRAD}" 3 POST TO SUPPORT STAIR STRINGER W-3 SCALE: 1" =1'-0" ELEVATION VIEW DECKING TREAD w/ 3/" to 1 4" NOSING CLOSED RISER (SHOWN) or CHILD -SAFE OPEN RISER SUCH THAT 4" 0 SPHERE CAN NOT PASS 2x12 PT STRINGER or PREFABRICATED EQUIVALENT 10" MIN. NOTE: STAIR SHALL TREAD r HAVE 3' x 3' MIN. CLEAR LANDING AREA, FINISHED i PER LOCAL CODE. 2x4 PT CLEAT w/ 4" 0 ANCHOR BOLT w/ WASHER & NUT - T' EMBEDMENT PAINT/COAT CUT ENDS OF STRINGER (TYP) - 24" NOTE: FTGS 8" WIDE x 4" THICK : DEPTH (MIN.) @ BOLTS MAY CONTINUOUS CONCRETE BE CIRCLES 24" DEEP x 8" 0 FTGS w/ or SQUARES 8. ANCHOR BOLTS PER PLAN I - AS DESIRED. 2 TYP STAIR FOOTING W-3 SCALE: 1" =1'-0" ELEVATION VIEW 9AHT� Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: decksadansmithm.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DCSPE 9: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction Sheet: W-3 of 16 PICKET & RAILING NOTES: • INSTALLER MAY SUBSTITUTE A PICKET DESIGN NOT SHOWN PER HOMEOWNI REQUEST THAT FOLLOWS LOCAL COI REQUIREMENTS. • RAILING REQUIRED FOR DECKS w/ 30" 1 MORE FROM GRADE to TOP OF DECKIN • USE GRIP -RITE #9 x 3" HDG NAILS or EQUIVALENT. PICKET (TYP) V' 0 SPHERE CAN NOT PASS (TYP) 1 42 GUARDRAIL PICKET SPACING W-6 SCALE: 3/4" -1'-0" ELEVATION VIEW PICKET (TYP) I'T POST (TYP) BAND or GIRDER (TYP) CLASSIC AUTORAIL AUTORAIL TRADITIONAL STANI)ARI) GUARDRAIL 34" MIN. ABOVE TREAD NOSING 4%s" 0 SPHERE CAN NOT PASS AND, IF GUARD RAIL PRESENT... 6" 0 SPHERE CAN NOT PASS Q \STAIR GUARD OPENINGS 6 SCALE: 3/4"-1'-0" ELEVATION VIEW INSIDE HANDRAIL POSTS OUTSIDE HANDRAIL POSTS 1 GUARDRAIL PICKET OPTIONS W-6 SCALE: 3/4" - V-9' ELEVATION VIEW MOUNTED TO WALL HANDRAIL NOTES: • HANDRAILING IS REQUIRED PER LOCAL BUILDING CODE REQUIREMENTS. MAY NOT BE REQUIRED IN ALL AREAS. • WHEN THERE ARE 4+ RISERS IN A FLIGHT OF STAIRS, TYPICALLY HANDRAILS MAY BE REQUIRED ON AT LEAST (1) SIDE. • HANDRAIL SHALL BE CONTINUOUS 34" - 38" IN HEIGHT. • HANDRAIL SHALL TERMINATE INTO NEWEL POST or SAFETY TERMINALS or HAVE END RETURNED. • USE A7 x 2Y4' S.S. TRIM HEAD SCREW or EQUIVALENT & 12" O.C. or (2) PER INTERSECTION FOR WOOD FASTENERS. • FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR METAL MOUNTING BRACKETS. HANDRAIL HEIGHT 34"-38" FROM TREAD (IYP' MOUNTED TO POST 4 HANDRAIL MOUNTING EXAMPLES W-6 SCALE:2"-1'-0" ELEVATION VIEW R0.01" MIN. PERIMETER 4" - 6Y4" 2)," MAX. 01y" - 2" IREF: 2012 IRC R311.7.8.3 oil 11/2 MIN. IY4"-2Y4' PERIMETER > 6s,- RDAI-MIN. (rn'1 •MAX _Z 7�-MAX. 16 -- MIN. MIN. IREF: 2012 IRC R311.7.8.3 r21 Daniel C. Smith, PE Consulting Engineer 5068 Isabella Cannon Dr Raleigh, NC 27612 P: 919.844.6050 ext 1 E: deckstvdansmithoe.com RESIDENTIAL ATTACHED DECK RECEIVED Jul 26 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 00 N � � (Ci � (n c ra c V "o r, (3N r 4-1 N I M U cv W DCSPE K: 23-D-036 Drawn By: ACS Revision History: X For Construction Not for Construction TYPE I HANDRAIL GRIP SIZE 6 TYPE Il HANDRAIL GRIP SIZE Sheet: W-6 SCALE: 4"- l'-0" ELEVATION VIEW W-6 SCALE:4"- I'-0" ELEVATION VIEW TA I_6 of 16