APPROVED PLN BLD BLD2023-0899+Architectural_Plan+7.18.2023_2.37.22_PM+3672824CONSTRUCTION REQ'S NOTES Project Data ,s d CODE REQUIREMENTS NOTES IRC R302 Building seperation to be greater than 5 feet from property lines with no eaves closer than 3 feet. IRC R308.4 Glazing in hazardous locations in doors, within 24 in of doors, close to floors, within 60 in of stairs and less than 60 in above stair landings, near enclosures for tubs, showers, and pool enclosures and less than 60 in above any walkable surface must be approved safety glass. IRC R309 Garage seperated from living space at residence with min. 1/2" type'x" gwb at all walls and structure. Ceilings below habitable space above require 5/8" type 'x' gwb. Doors connecting to be min 1-3/8" thick solid core or 20 minute fire -rated. IRC R 309.3 Garage floor to be constructed of noncombustible material. IRC 310 Escape and rescue windows to have min 5.7 sq ft net clear open area with max sill ht of 44 in. Minimum clr open width is 20 in and min clear open ht is 24 in. IRC R311.5 Stair min width 36" finished dims with max 7 3/4" rise and min 10" run. 6' 8" min head room required with a graspable handrall between 34-38" and between 1.25" and 2" gripping dimension. IRC R312 Guard rails req'd for walks 30" above adjacent grade and to be min 36" ht. IRC R314 An 110v interconnected smoke detector with battery back up req'd in all sleeping rooms and outside sleeping areas, and all floors. Alarms must be clearly audible in all bedrooms. Alarms to be installed at highest ceiling in sleeping areas. IRC R315 Carbon monoxide alarms installed outside sleeping areas with fuel fired appliances and/or dwelling units with attached garages. Alarms listed to comply with UL 2034. IRC R330 Exterior doors must have security features including 1/2" minthrow dead bolt or latch, visitor observation port, and operable without key special knowledge or effort. Windows accessible within 10 ft of grade or deck must have locking latch. IRC R502.12, R602.8 Draft stop in all clg and floor assemblies so concealed space does not exceed 1000 sq ft. Fire blocks required at all occupancy seperations at floor levels and minimum 10 foot vertically in walls and at concealed spaces. provid 5/8" type 'x' gwb to protect all stair structure. IRC R807 Attic Access (if required) to be 22 x 30 in min with min 30 in head room at access hatch. Completely seal and weatherstrip access hatch to air and moisture vapor movement per 2015 WSEC. IRC R703.2, R903 Weather protection for all walls and opening to include weather resistant barrier, min 26 ga galv metal flashings at head and sill and appropriate seals and overlaps to allow water to drain out and away from the envelope. Per the 2015 WSEC a complete air and moisture barrier should be constructed continuously at the exterior envelope to protect and enhance the building materials within. WAC 51-13 (formerly Wash State VIAQ code) Habitable rooms must have outside air supply and kitchens, bathrooms, laundry rooms, must be vented mechanically. Fans to be rated Energy Star compliant. APPROVED BY PLANNING Witt- Z Aug 02 2023 Foundations: Ftgs must bear on undisturbed soil a minimum of 12" below finish grade inclusive of deck supports. See structural notes and details for all steel reinforcement and tie details as well as anchorage req's. (min 1/2 in x 10 in anchor bolts with 14 in thick 2 in x 2 in plate washers at 6 ft on center spacing and within 12 in of sill joints. Concrete IRC table R402.2 Soil types IRC table R401.4.1 Assumed 2000 psf bearing unless in ECA or pre site visit requires otherwise. Wood/Earth Seperation: IRC R319.1 Pr tr wood or cedar req'd for wood in contact with concrete or earth. At sill conditions provide closed cell foam sill gasket and sealant to create an effective air barrier and a good capillary break for moisture migration. Wood structural sizes and connections: See Engineering calculations notes and details for specifics of loading and placement to resist gravity and lateral loads. Metal fireplaces and chimneys: IRC R1002 Provide UL or ICC approved prefab. mfr unit installed per mfr instructions and supplied with a min of 6 sq in outside air with seperate exhaust equipped with manual or automatic back draft damper mechanism. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED CLANS MUST b ON JOB SITL City Of Edmonds Building Department Work DECK -------------------------- Address 23830 78TH AVE W --------------------- Owner HEDLUND Approved Date 08/01 /2023 Building Official Eri. ------------------------------ Permit Number:BLD2023-0899 REVISIONS DATE PAGES CHANGES REV1 REV2 REV3 REW REV5 Summary of Work New deck constructed in the City of Edmonds, including associated minor excavation for post footings Address: 23830 78th Ave W Edmonds, WA 98026 Legal Description: SEC 31 TWP 27 RGE 04RT-10A) TH PTN W1/2 NE1/4 SE1/4 DAF BAAP 30FT N & 30FT W OF SE COR SUB TH N 310.95FT TPB TH CONT N 95FT TH W 127FT TH S 95FT TH E 127FT TO TPB Plat Block: Township 27; Range 04; Section 31; Quarter SE Parcel Number: Snohomish County Assessor Parcel Number: 27043100401100 Permit and Code Information Current Permit Submittal Building permit application for new deck along with necessary excavation and site work permits Deferred Permits Permits by others for bidder -design by plumbing, mechanical, and electrical prior to start of work from contractor or subcontractor companies. Applicable Codes Zoning and Land Use Construction Codes Building Code Structural Code Fire Code Plumbing Code Mechanical Code Energy Codes Electrical Code Zone - Land Use District R S-8 Occupancies R-3 and U Edmonds Community Development Code (ECDC) City of Edmonds as follows: Edmonds Municipal Code and City Construction Codes as amended by the State of Washington Building Code Council 2018 International Residential Code 2018 IBC & IRC - (WA State Amendments to International Building Code) 2018 International Fire Code & NFPA Standards 2018 Washington State Plumbing Code with WA State Amendments 2018 International Mechanical Code with WA state Amendments 2018 WA State Energy Code - Residential Provisions (basis of Washington State Residential Energy Code) 2020 National Electrical Code Type of Construction Type VB Light wood frame, all wood exposed to weather pressure treated and protected for rot & decay, slab on grade, wood joists as noted, rail system attachments per Simpson deck design hand book engr mfr requirements, verify existing conditions prior to start of deck addition Fire protection Fire protection per applicable code SRC section R302 with modified 1 hour occupancy separations provided between garage and living spaces per SR0 table R302.6. Remodeled Deck Area Summa See sheet A 0.1 Sheet Index General Architectural A 0.1 cover sheet including project team, symbols key, project data, sheet index, general notes A 1.1 foundation plan existing, foundation plan new, deck framing plan existing, deck framing plan new, foundation details, general notes A 2.1 deck plan existing, deck plan new, site plan, plan keynotes, plan symbols key A 3.1 e existing elevations, keynotes A 3.1 new elevations, construction assemblies, A 4.1 details, door schedule, stair regs detail General Notes 1. Do not scale drawings. Written dimensions take precedence 2. Drawings have been prepared on an original sheet size of 24" x 36". 3. Horizontal dimensions shown customarily indicate face of (F.O.) concrete, F.O. Masonry, F.O. framing, centerline of gridline as shown. Dimensions only indicate F.O. finish, and F.0 sheathing when specifically noted. 4. Information regarding existing conditions used to prepare these drawings has been provided by others. Contractor to field verify existing conditions prior to commencing construction. Provide written notification to the architect of any discrepancies between existing conditions and the drawings. The Architect will issue a written directive if further clarification is required. 5. Contractor to field verify all dimensions, datum, levels, and conditions pertaining to the work prior to commencing construction. Provide written notification to the architect of any discrepancies with the documents. The Architect will issue a written directive if further clarification is required. 6. These drawings are the exclusive property of Cloward Sustainable Design and have been prepared for use in the execution of the enclosed project. Use or reproduction for any other purpose without the written permission of Brian Cloward Architect is prohibited. Construction Assemblies See architectural section sheet A ? for Typical and specific envelope and construction assemblies. Nyeuilding erm it,COm MyBui 1,diingPermit Cord aserykeof, ectry&vfltet Construction Tip Sheet 05 aservice ofmvmt Construction Tip Sheet 05 Deck Construction Notes Connections and Fasteners 0 Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead (All fasteners, nails, bolts, screws, and connectors must be corrosion resistant.) load, and 1500 PSF soil -bearing capacity. • The illustrations and information in this tip Sheet may be used for decks whether or not they require a permit. See Tip Sheet 0 for when a permit is required. • All wood must be pressure -treated or naturally resistant to decay. Treat cuts; holes, and notches with end -cut solution. • Fasteners, hangers, nails, etc., must be stainless steel, hot -dipped galvanized; or as specifically required for the specified wood preservative used. The coating weights for zinc -coated fasteners to be in accordance with ASTM A 153. Provide documentation in the field showing the required fastener protection for the wood chosen for your deck. You may modify any components of this Tip Sheet using accepted engineering practices. Any modifications must be reviewed prior to permit issuance. All attachments must be per Type of Connection: Notes: Manufactured Connectors Follow manufacturer's instructions Post to Footing Post base is required Post to Footing (High Winds) Post to Beam Consult with jurisdiction about additional uplift loads where wind exposure is greater than Risk Category B Connector is re uired See information on Sheet 5 and Sheet 6 Ledger to House Framing Joist to Beam or Girder 3 8d — Toe nailed Blocking or Bridging to Joist 2 10d — Toe nailed at each end Wooden Deck Boards 2 8d threaded nails OR 2 No. 8 screws Composite Decking Follow manufacturer's instructions manufacturers installation instructions. Visit MyBuildingPermit.com for additional Tip Sheets for stairs, handrails; and notching and Post to Beam Connection with Knee Brace boring. (Knee braces are required on posts greater than 4 feet in height ) 36" n-Mmum high guard - with intermediate rails spaced so that a sphere Existing building 4" in diameter cannot pass through (See Tip �- Flashing Sheet 3} See detail 1 on page 6 for ledger - Refer table on page attachment options 3 for Joist Sizes i- Jr Decking f and Spans Note: Contractor to (bid verify adequacy of sd'td lumber for connection. ledger tl� sparing recommended for drainage If an exit or egress from the existing building passes under the pproposed deck, or R (here Is an exlsting patio under the proposed deck, 6-8" minimum clearance must be maintained. Please Attachment of pre -manufactured guardaN systems to deck components shall be per manufacturer. Specal blocking details may be required by the reviewer. 1</� See page 8 for guardrail post connection Secure balusters wkh (1) #8d wood screw lop d botlom Refer to Table on page 3 for Beam Size and Spans Knee braces are required if distance from grade to top of post exceeds 48". See delal on page 7 For post size and maximum alowabk heght, see page 4 C)r f`(3 the'�iekghE'Cf tit' ��- _ which�Ver is gre�ije Beam splices must occur over Dosts N0 1-112" min;. beannc Corrosion resistant. - �2' mnz metal column. cap. -----1 `- Girder beam FLi I;;:h n-a-ufactwer's t ntiLi I::' w nstructfons. / ` - 4 x 4 knee brace .a (11 3.,V,dianieter thru-boll or 1;2 " Altern.�ite Knee Brace [?alai -' lag screws with washers. top bottom 2x4 knee brace lace nailed c-a, side o' (typical) post and beam •,,;ith 4-16a nails at etch Pressure treated face and connection wood post Indicate openings In Manufactured post base cast In Nting wall in elevation footing vieRefer to Table on page 4 for Footing Size 3,000 pal concrete (no special Mspectbn required) Flnished grade 1' deer MlMfflurn [2) #4 ea. way; 3" dear depth or~-� ��pp bottom of footing rooting 12" Footing to bear on undisturbed earth. January 14, 2022 MyBuildingPermit.com I Basic Deck January 14, 2022 MyBuildingPermit con I Basic Deck eOtyG ,:f1et City Project Team Permit Agency: City of Edmonds Building Division 121 5th Ave N Edmonds, WA 98020 Owner: Robert Hedlund & Jenifer Ferguson 23830 78th Ave W Edmonds, WA 98026-8821 (206) 718-3157 email: vintageseattle@gmail.com Consultants: Architecture Cloward Sustaianble Design 630 NW 81 st Street Seattle, WA 98117 contacts: Brian Cloward, Architect (206) 755-0759 e-mail: briancloward@comcast.net General Contractor/Builder Owner see above SQUARE FOOTAGE SUMMARY existing main floor 1256 SF existing basement 920 SF Total Living Space: 2176 SF existing detached garage 780 SF existing deck & stairs 120 SF new deck 280 SF new deck stairs 48 SF Symbols 1� revision number tag north arrow 4 drawin or detail title Scale. 1/8 - 1 -0 grid line b building section A 3.2 designation over sheet number i elevation detail tag A 2.1 designation over sheet number i I detail tag A 6.1 designation over sheet number scale reference 0 2 4 8 16 bar PLAN SYMBOLS KEY: so Smoke detector with audible alarm Interconnected within building - 110 v wiring with battery back up. co Carbon monoxide alarm approved & listed as complying with UL 2034 & installed per mfr Instructions. 0 Gas piping and stub for future appliance. HB Hose bib - freeze protected at exterior 0 Water valve Energy Star rated fan suitable for noted capaclty vented to outside & including back draft damper, vent shroud, flashing and weather seals. Intermittent operation typ unless noted otherwise. Thermostat control for mechanical heating system briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions Rev Date Description 2023-xx 0 2023-xx Q sheet contents sheet index, project team, project data, symbols legend, code notes, general notes mod fire separation regs. professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 0.1 July 17th, 2023 GENERAL NOTES: foundation plan - existin L — F_ I®I existing deck above I ®I I POST PER PLAN &ENGR ■ ■ Hardware and fasteners in contact with PB66 POST BASE preservative -treated wood shall be of ■ ■ hot -dipped zinc galvanized steel, BASE TRIM PROVIDE SLAB SEALER stainless steel, silicon bronze or copper. ■ AFTER CURE In the absence of manufacturer's SLOPE GRADE AWAY ■ recommendations a minimum of ASTM A 653 11-1 ■ type G185 zinc -coated galvanized steel, or I ill--li I=III= equivalent shall be used. lli-I ■ 11=111= ■ IRC R317.3.1 IBC 2304.10.5.1 III-1 foundation plan - new Scale: 1/4" = 1'-0" U Structural reference note for foundation details: Scale: 1/4" = 1'-0" All footings sized & connections/anchorage in accordance with prescriptive requirements of 2018 IRC with WA amendments Section R507 Decks - Specifically R507.2.3-4, & R507.3 Footings 1. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 2. THE MINIMUM DEPTH OF EMBEDMENT FOR ALL FOOTINGS SHALL BE 18 INCHES. EXT TRIM PER PLAN & 3. STEP FOUNDATION PER SITE CONDITIONS..VERIFY STEP LOCATIONS W/ BUILDER ELEVS 4. ALL FOOTINGS TO REST ON FIRM UNDISTURBED EARTH ASSUMED MIN. 2000 PSF BRIG. PROVIDE WRB GASKET (REFER TO SOIL REPORT WHEN REQUIRED.) WRAP POST BOTTOM 5. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY OR EXPOSED TO EARTH OR WEATHER TO BE PRESSURE TREATED. #4 STEEL REBAR EA WAY PER PLAN AT NEW 6. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. FTGS 7. PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENINGS HAVE BEEN INSTALLED. POUR FTG TO BE MIN 12" 8. PROVIDE DBL. JSTS. OR BLOCKING AT PARTITIONS ABOVE. BELOW FINISH GRADE 9. IF APPLICABLE F.V.: 16" X 8" FOUNDATION VENT WITH 1/4" CORROSION RESISTANT a — WIRE MESH AS REQ'D. PER CODE. Ell I 1— a I III1=1I 10. CRAWL SPACE: PROVIDE 18" MIN. CRAWL SPACE BELOW JOISTS, 12" MINIMUM CLEAR eba. a a I I I-1 I E II I II I BELOW BEAMS. GROUND TO BE COVERED WITH 6-MIL BLACK POLY. VAPOR BARRIER a II II LAPPED 12" AT SEAMS AND UP FOUNDATION WALL TO SILL PLATE TYP. 1=1I1=1I 11. ALL FRAMING AT VENEER LOCATIONS TO BE 4 1/2" FROM FRONT OF FOUNDATION. -I I II I II I II I IIIII I II11111II I HOLD SILL TO INSIDE. I II I II I II 12. MIN. 1 1/2 CLEARANCE TO CONCRETE AT BEAM ENDS. PER FOUNDATION PLAN 13. PROVIDE CONTROL JOINTS AND WIRE OR REBAR REINFORCEMENT FOR SLABS ON GRADE, PROVIDE INSUL &THERMAL BREAK AT EDGE NEW POST FTG AT EXTERIOR existing basement 3/4" 1'-0"d existing eck I existing basement abov, ®I Lateral tension ties to be installed in accordance with IRC 507.9.2 ; -------------------------------------775 - Install Simpson BVLZ connectors in accordance with reviewed information. Joists longer than 8 feet shall have reinforced floor framing per Simpson details. deck framing plan - existin 2x12 with BVLZ brick veneer ledger connector min 18" oc- x edger he y impson_ bric v r connector ea. joist bay - install per mfr eng II o LCE4 new deck above post cap patio below all joists & posts to be :0 pressure treated - wrap with 33 0 O ptd or stained cedar for 0 E appearance � L X (V `J 6x6 x post 3 - 2x12 doug. fir #2 or bette _ AC6 post cap LCE4 post cap 6x6 76x6 post cap post post 1 16'-0" deck framing plan - new ® -7] existing eck abov X � CV N .7 I� 5 c N existing rim be CD CD �I ofNI LL �I new dou . it #2 or x better 2xl0 deck II joists @ 16" oc X L2x126x6 poststm F #2 or better S m s n LCE4 ost aps typ I I� 4) 2x12 stair DF#2orI 5 n1 O1-011 anding briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions Rev Date Description 2023-xx 0 2023-xx Q _ V co �o > M co QQ a 00 U P, N O Y 3 CM 00 0 CV _0 W 80 v G) sheet contents 0 gers r Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" 0 1 2 4 8 Structural reference note for framing details: All footings sized & connections/anchorage in accordance with prescriptive requirements of 2018 IRC with WA amendments Section R507 Decks - Specifically R507.4 Deck Posts, R507.5 Deck Beams, R507.6 Deck Joists, R507.7 Decking, R507.8 Vertical & Lateral Supports, R507.9 Vertical & Lateral supports at Band Joist foundation plan lower floor plan foundation details general notes professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 1.1 July 17th, 2023 roof plan - existin Scale: 1/4" = V-0" CL U CT ey e eupo q o 0 0 O 1111111111101 site NO Owners: Robert Hedlund & Jenifer Ferguson Scale: 1/4" = V-0° LEGAL DESCRIPTION: SEC 31 TWP 27 RGE 04RT-10A) TH PTN W2 NE1 SE1 DAF BAAP 30FTN & 30FT W OF SECOR SUB TH N 310.95FT TPB TH CONT N 95FT TH W127FT TH S 95FT TH E 127FT TO TPB Snohomish County Assessor Parcel Number: 27043100401100 deck plan - existin 8'-0" Scale: 1/4" = V-0" PLAN SYMBOLS KEY: s� Smoke detector with audible alarm Interconnected within building -110 v wiring with battery back up. co Carbon monoxide alarm approved & listed as complyying with UL 2034 & installed per mfr Instructions. 0 Gas piping and stub for future appliance. HB Hose bib - freeze protected at exterior 0 Water valve Energy Star rated fan suitable for noted capacity vented to outside & including back draft damper, vent shroud, flashing and weather seals. Intermittent operation typ unless noted otherwise. Thermostat control for mechanical heating system PLAN NOTES: 1. HEADERS AT EXTERIOR TO BE INSUL PER 2015 WSEC UNLESS NOTED OTHERWISE ALL WINDOWS AND FRAME TYPES TO COMPLY WITH 2O15 WSEC PROVIDE INSUL SEAL AND COMPLETE AIR AND MOISTURE BARRIER AT PERIMETER, PROVIDE 26 GA PTD METAL HEAD AND SILL FLASHING -SLOPE SILL PANS/THRESHOLDS TO DRAIN TO EXT. 2. FRAMERS TO VERIFY ALL ROs WITH BUILDER & MFR PRIOR TO FRAMING START 3. ❑ DENOTES SOLID POSTING TO CONCENTRATED LOADS ABOVE 4. COORDINATE AND REVIEW ARCH AND ENG DETAILS FOR CONNECTIONS & CONSISTENCY, CONSULT ARCH OR BUILDER FOR CONFLICTS OR QUESTIONS 5. ALL PLUMBING FIXTURES TO MEET EPA WATERSENSE CERTIFICATION WHERE APPLICABLE 6. CEMENT BOARD OR MATERIAL OF EQUIVALENT WATER RESISTANCE REQUIRED AT ALL TUB AND SHOWER DECKS AND ENCLOSURES (MIN 70 IN ABOVE TUB INLETS) INSURE COMPLETE AIR AND INSUL AT CONCEALED SPACES, SEAL FOR WATER PENETRATION PRIOR TO INSTALLATION OF FINISH SURFACE, & CHECK FOR LEVEL AND SQUARE FRAME 7. ALL ELEMENTS AND SWITHCHES FOR FURNACE AND WATER HTR MIN 18 IN ABOVE FLOOR AND PROVIDE PROTECTED INSUL AT BASE 8. DRAWING SHOWS 2X6 EXT FRAME WITH ADVANCED FRAME ENERGY TRUSSES AT ROOF, FRAMER TO VERIFY ACTUAL HEEL HT TO ALIGN GUTTERS AS NEEDED 9. FRAMER TO COMPENSATE FOR DIMENSIONAL ADJUSTMENTS FOR 2X4 WALLS TO ALIGN WITH 2X6 WALLS 10. PROVIDE MIN 31" FINISH DIMS AT ALL WATER CLOSET LOCATIONS 11. PROVIDE FIRE STOPS AND BLOCKING PER 2015 SEATTLE RESIDENTIAL CODES deck plan - new Plan Keynotes stair handrail & guard not less than 34 in. & not more than 38 10 in. with max. 2" graspable top per src section 311.7.8 & railing portion with max 4" openings per src sec 312.1.3 0 guard rails shall be installed per src section 312 & be not less than 36 in. in height with max 4" openings per src 312.1.3 0 3 ext. door frame seal at all gaps, threshold, jambs and head - provide slope & water stop at ext threshold, insul & weatherstrip Scale: 1/4" = V-0" 0 1 2 4 8 > Qi N CL 0 Q O U) CI ,s d Rev Date Description 2023-xx 2023-xx Y U 0 briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions 0 Q co N O 00 > OF) Q Q 00 ti U) O co W O CM E N —0 W a sheet contents deck plan - new deck plan - existing roof plan - existing site plan plan keynotes general notes professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 201 July 17th, 2023 i s d Elevation Keynotes notes are typical, unless noted otherwise mfr. energy code compliant windows typ see schedule for sizes operability as 1e shown on elevations verify with bldr/owner. Install per mfr specs & details mfr. energy code compliant exterior vinyl, fiberglass, aluminum store door, or 2e sldr. thermally broken, with weatherstripping & threshold see schedule - safety glass for all glazing. Install per mfr specs & details, verify rough openings 3e roof downspout - drains to approved system engineered stem walls per structural details - all rebar steel and conc footing sizes 4e per structural engr. - see structural plans for holdown placement and verify in field with builder or architect prior to pour 5e proposed electrical meter location - verify with bldr and utility provider 6e gas meter location - verify with bldr and utility provider 7e exterior lighting base and fixture - shield for light pollution per SRC see A0.1 8e anchored signage for address 9e over head garage door - install and balance per mfr. specs & details 10e egress window or door 0 11e prefabricated engineered mfr. metal guard & hand rail system. provide shop drawings for architect and bldg dept approval. Install per mfr specs & details engineered mfr roofing system review mfr installation guides & drawings - install 12e per mfr specs & details - all edge flashings over pressure treated face plates with 26 ga. ptd. metal drip edges at vert surfaces 13e prefab mfr. & engineered metal stair system including attachments for posts - coordinate connection details with support structure per structural engineer 14e max. encroachment of combined eaves and gutters into any required yards is 18" elev xx high poi main fir. plate main fir hdr. main floor elev xx lower fir plate lower fir hdr. elev avg grade xx 1 r _1 lower fir. elev xx r n . preserve anr i■■■■■■■■■■■■■, i■■■■■■■■■" ins r i■■■u■i■■■■■■■ur i■■■■■■■■■■■■■r i■■■■■■■■■u�■■r i■■■u■i■■■■■■■ur ■■■■■■■■■■■■■1 ■■■■■■■■■IMI AI ■■I■Ir■I■■■■■■I■III i■■■■■■■■■■■■■r i■■■■■■■■■u■ir■r i■■■u■i■■■■■■■ur i■■■■■■■■■■■■■r i■■■■■■■■■u■■■r i■n■u■i■■■■■n■ur i■■■■■■■■■■■■■r i■■■■■■■■■u■■■r i■m■u■iM■■■■■■ur 1WWWWWWWWWWWWW1 IMMMMMMMMMIIIIL=e 1 I I existina new west - rear elevation elev xx elev avg grade xx :: , lower fir. elev xx east - front elevation TYP CONSTRUCTION ASSEMBLIES EXISTING JOISTED DECK: INSPECT ALL EXISTING CONNECTIONS AND JOISTS REPLACE AND RETROFIT NEW CONNECTIONS TO MATCH NEW AS NEEDED - OPT. TO REPLACE EXISTING GUARD RAILS TO MATCH NEW DECK AREA - REFINISH OR REPLACE EXISTING DECK SURFACE AREAS TO MATCH NEW JOISTED DECK AREAS NEW JOISTED DECK: FINISH WALKABLE SOLID BODY OR SEMITRANSPARENT STAIN APPLIED TO FSC CERTIFIED TROPICAL HARDWOOD SUCH AS IPE OR TIGERWOOD OVER PRESSURE TREATED DECK JOISTS - SEAL ALL CUT ENDS WITH WOOD PRESERVATIVE - PROVIDE HANGERS AND INSTALL PER MFR ENGR & SPECS - ALL SPANS AND SUPPORTS IN ACCORDANCE WITH 2O18 IRC WITH WA STATE AMENDMENTS SECTION R507 DECKS INCLUSIVE. NEW DECK SUPPORTS: ALL FTGS, POSTS, BEAMS, RIMS, & STRINGERS ARE CONNECTED & PRESCRIPTIVELY SIZED ACCORDING TO SECTIONS & TABLES R507.3.1 (CONIC FTGS) & R507.4 (POSTS), R507.5 (BEAMS), & R507.6 (JOISTS) Scale: 1/4" = 1'-0" 4 Scale: 1/4" = 1'-011 L r south - side elevation north - side elevation Scale: 1/4" = 11-0" Scale: 1/4" = 1'-0" 0 1 2 4 8 briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions Rev Date Description Q 2023-xx 2023-xx Q chant rnntantc elevations - new elevation notes professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 301 July 17th, 2023 ,s d TYP CONSTRUCTION ASSEMBLIES EXISTING JOISTED DECK: INSPECT ALL EXISTING CONNECTIONS AND JOISTS REPLACE AND RETROFIT NEW CONNECTIONS TO MATCH NEW AS NEEDED - OPT. TO REPLACE EXISTING GUARD RAILS TO MATCH NEW DECK AREA - REFINISH OR REPLACE EXISTING DECK SURFACE AREAS TO MATCH NEW JOISTED DECK AREAS NEW JOISTED DECK: FINISH WALKABLE SOLID BODY OR SEMITRANSPARENT STAIN APPLIED TO FSC CERTIFIED TROPICAL HARDWOOD SUCH AS IPE OR TIGERWOOD OVER PRESSURE TREATED DECK JOISTS - SEAL ALL CUT ENDS WITH WOOD PRESERVATIVE - PROVIDE HANGERS AND INSTALL PER MFR ENGR & SPECS - ALL SPANS AND SUPPORTS IN ACCORDANCE WITH 2O18 IRC WITH WA STATE AMENDMENTS SECTION R507 DECKS INCLUSIVE. NEW DECK SUPPORTS: ALL FTGS, POSTS, BEAMS, RIMS, & STRINGERS ARE CONNECTED & PRESCRIPTIVELY SIZED ACCORDING TO SECTIONS & TABLES R507.3.1 (CONIC FTGS) & R507.4 (POSTS), R507.5 (BEAMS), & R507.6 (JOISTS) west - rear elevation existinc Scale: 1/4" = 1'-0" �11 east - front elevation existinc Scale: 1/4" = 1'-0" elev xx elev xx south - side elevation existinc Scale: 1/4" = 1'-0" north - side elevation existing Scale: 1/4" = 1'-0" 0 1 2 4 8 briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions Rev Date Description 2023-xx 0 2023-xx Q U Duo �o00 � M 00 O co E 0-11 ^, W W sheet contents elevations -existing plan notes plan keynotes professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 3.1e July 17th, 2023 WALL SHEATHIING, TYP. SEE SHEET A4.0 FOR ASSEMBLIES WINDOW OPENING, TYP 1. APPLY WRB OVER EXT. SHEATHING 2. APPLY HORIZONTAL FLEXIBLE SILL FLASHING FASTENED ALONG TOP EDGE ONLY. 3. INSTALL (2) CORNER SILL FLASHINGS 4. INSTALL FLASHING STOP (VERIFY THICKNESS AND WIDTH PER WINDOW FRAME DIMENSIONS AND CONFIGURATION). PROVIDE 1/8" - 1/4" GAP BETWEEN WINDOW FRAME AND SILL PAN BACKLEG FOR SEALANT, APPLIED AFTER WINDOW INSTALLATION. 5. INSTALL FLEXIBLE FLASHING SILL PAN - FULL WIDTH OF OPENING - EXTEND OVER CORNER FLASHINGS. FORM BACK DAM AGAINST FLASHING STOP. PROVIDE METAL SHEET PAN FLASHING WITH SOLDERED END DAMS WHERE WINDOWS ARE LOCATED ON TOP OF CONCRETE STEM WALL. 1►1 6. ADD CONTINUOUS BEAD OF SEALANT ALONG EDGE OF FLEXIBLE FLASHING (BOTH WINDOW INSTALL & FLASHING SEQUENCE SIDES) STAIRS PER SRC SEC 311 1.5 IN DIA GRASPABLE HANDRAIL 34 IN MIN - 38 IN MAX HT ATTACH SECURELY & RETURN TO WALL PER SRC SEC R311.7.7 RISER - TYP. 7 3/4" MAX. LANDING FRAMING 2-2x HEADER PER STRUCT LSC STRINGER HANGER ATTACH PER MFR ENGR (3)2xl2 STRINGERS TYP. 5/8" TYPE X GWB OVER ALL HABITABLE SPACES TREADS-TYP. TOENAIL TO CLEAT & FRAME BELOW FLOOR DECKING 2x CLEAT 2-16d TO EACH JOIST BELOW H 111 1n" TVD STAIR FRAME GUARDRAIL AND HEAD HEIGHT niAr-QAnn 7. INSTALL 18" FLEXIBLE FLASHING AT JAMBS. LAP OVER SILL PAN AND SILL STRIP AND WRAP ENTIRE JAMB 8. INSTALL 18" FLEXIBLE FLASHING AT HEAD. LAP OVER JAMB WRAPS (FOLD HEAD WRAP IN 2") niAr-QAnn 1 INT. CASING TRIM PER OWNER/BLDR. SPEC. WEATHER STRIPPING SYSTEM AT DOOR PROVIDE SEALANT AS AIR & MOISTURE BARRIER DOOR OR WINDOW FRAME W.R.B FOLD OVER INTO ROUGH OPENING SEALANT FLEX FLASHING &WRB SEE DETAIL 4 SHEET A4.1 FOR WINDOW INSTALLATION SEQUENCING & FLASHING REQS. VERIFY PER MFR. REQS, SPECS. & INSTALLATION INSTRUCTIONS EXT. DOOR -WINDOW JAMB AT SIDING � o i O L C O E aD N c O 6'-0'1 3'-0" IL oSG SG 9. SET 1/8" THICK NON -CORROSIVE SHIMS AT SILL PAN (ONE AT EACH SIDE) TO CREATE AN OPENING TO DRAIN WATER. 10. APPLY SEALANT TO BACK SIDE OF MOUNTING FLANGE AT HEAD AND JAMBS ONLY 11. INSTALL WINDOW - SHIM AND ADJUST TO ACHIEVE PLUMB AND SQUARE PER MANUFACTURER'S RECOMMENDATIONS - USE CORROSION RESISTANT FASTENERS. 12. AFTER WINDOW INSTALLATION, SEAL FRAME SEAM JOINTS AT CORNERS EXTERIOR DOORS insulate, VERIFY all rough openings with builder and mfr weatherstrip & air seal per DETAIL KEY eA wsec and mfr details and specs EXTERIOR QUANTITY: 1 SRC R302.5 & R302.6 - fire separation doors eA at garage to dwelling to be solid wood or honeycomb core steel doors not less than 1-3/8" thick, or doors with min 20 min fire rating. In all cases the doors shall be self closing & self latching exterior door schedule 14. INSTALL 9" WIDE FLEXIBLE FLASHING AT HEAD, LAP OVER JAMB STRIPS AND WINDOW MOUNTING FLANGE 13. INSTALL 9" WIDE FLEXIBLE FLASHING AT JAMBS, LAP OVER WINDOW MOUNTING FLANGES. EXTEND 4" ABOVE AND BELOW WINDOW FRAME. MAr--QAnn n TYP. EXT. WALL ASSEMBLY R-10 RIGID INSULATION SEAL IN CAVITY Q EXT. FINISH PER ELEVATION 00 WRB SEE DETAIL 4 SHEET A4.1 FOR wLU U) SEQUENCING STEPS Ii Q ~ FLEXIBLE Scale: 1/4" = V-0" ADHESIVE FLASHING HEADER PER STRUCT. 26 GA. PTD. METAL FLASH'G PTD. TRIM WITH DRIP W.R.B FOLD OVER INTO ROUGH OPENING SEALANT FOR AIR & MOISTURE BARRIER DOOR OR WINDOW FRAME PROVIDE CC FOAM INSUL CONT. TO STUDS FOR AIR & MOISTURE BARRIER MFR. WEATHER STRIPPING SYSTEM AT DOOR EXT. DOOR -WINDOW HEADER AT SIDING niAr�_DAnn CZ DOOR SWING VARIES SEE PLAN 16. INST OVER D LEG ANI METAL HEAD DRIP FLASHING WITH END DAMS niA(N-QAnn R 1 /2" V-0"d II I� u I I DOOR PER PLAN &SCHEDULE 24 GA. METAL PAN FLASHING SEAL TO SILL, SHIM TO DRAIN TO EXTERIOR CONT UP JAMBS MIN 2 IN THRESHOLD, INSUL, AIR SEAL & WEATHERSTRIP PER 2012 WSEC Eno, Wo....—A TYP SOG AT GROUND FLOOR OR FLOOR DECK AT 2ND AND 3RD FLOORS OR ENTRY ABOVE GRADE THRESHOLD AT EXT DOOR MFR. DECK PAVER SYSTEM - PROVIDE SUPPORT & INSTALL PER MFR DETAILS & SPECS (AT GARAGE EX. CONC SLAB) Z MFR WP BARRIER DECK ME URANE - INSTALL PER MFR DETAILS AND SPECS SPACER AS REQ'D PER MFR COMPOSITE MATL WR SILL BASE - SEAL TO CONC. AT GROUND FLOOR - PROVIDE MFR. RECOMMENDED SILL GASKET AT ALL DECKS/PATIOS MATERIAL FOR AIR & MOISTURE BARRIER, DECK/PATIO EXPANSION JOINT, & THERMALBREAK s �z Rev Date Description 2023-xx 2023-xx briancloward @comcast.net 630 nw 81 st Street Seattle, wa 98117 206.755.0759 revisions a sheet contents Details exterior door schedule professional stamp below jurisdiction stamp below RECEIVED Jul 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT permit review A 401 July 17th, 2023