APPROVED BLD2023-1072+Structural_Plan+8.18.2023_1.49.56_PM+3734907STRUCTURAL NOTES CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE LOCAL JURISDICTION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS LIVE LOADS: DECK 60 PSF SNOW 25 PSF SPECIAL INSPECTION SPECIAL INSPECTION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDICTION FOR THE FOLLOWING ITEMS. • SOILS (SECTION/TABLE 1705.6) • CONCRETE (SECTION/TABLE1705.3) • WOOD (SECTION 1705.5) ALL INSPECTIONS SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION REPORTS. IF ANY INSPECTION FAILS TO MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, IT SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDITION. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR ANY SPECIAL INSPECTIONS REQUIRED. NOTIFY THE ENGINEER A MINIMUM OF ONE WEEK PRIOR TO THE OBSERVATION. FOUNDATIONS: THE FOLLOWING SOIL DESIGN PARAMETERS HAVE BEEN ASSUMED. IF EXCAVATION SHOWS THAT SOIL CONDITIONS DO NOT MATCH THE LISTED DESIGN VALUES, A GEOTECHNICAL ENGINEER SHALL BE RETAINED TO EVALUATE THE SOIL CONDITIONS. NOTIFY THE ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. • 1,500 PSF (ALLOWABLE BEARING PRESSURE) • 35 PCF+ SURCHARGE (ACTIVE LATERAL PRESSURE) • 200 PCF (PASSIVE PRESSURE) • 0.35 (COEFFICIENT OF FRICTION) FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL AS REQUIRED BY THE GEOTECHNICAL ENGINEER. FOOTINGS SHALL BE PLACED AT A MINIMUM OF THE FROST DEPTH REQUIRED BY THE LOCAL JURISDICTION. FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. FINAL FOUNDATION ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND SHALL BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BENEATH THE STRUCTURE ABOVE, UNLESS DIMENSIONED OTHERWISE. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING EXCAVATION, PILE INSTALLATION, AND ANY OTHER CONSTRUCTION EARTHWORK. NOTIFY THE UNDERGROUND UTILITIES LOCATION SERVICE AT LEAST 1 WEEK PRIOR TO CONSTRUCTION AND INDEPENDENTLY VERIFY ALL UTILITIES WHICH MAYBE AFFECTED BY THIS PROJECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL DAMAGE DAMAGE TO UNDERGROUND UTILITIES RESULTING FROM THEIR WORK. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF Th WOOD FRAMING ALL WOOD FRAMING SHALL BE PERFORMED IN ACCORDANCE WITH IBC CHAPTER 23, ANSI/AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", AND AITC "TIMBER CONSTRUCTION MANUAL". SAWN LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF AN AGENCYAPPROVED BYAN ACCREDITATION BODY COMPLIANT WITH DOC PS 20. ALL GRADES SPECIFIED IN THE STRUCTURAL DRAWINGS ARE MINIMUM STANDARDS AND SHALL BE AS FOLLOWS: • STUDS, PLATES, AND BLOCKING HEM -FIR STUD GRADE • JOISTS DOUG-FIR #2 • 4x OR SMALLER BEAMS AND HEADERS DOUG-FIR #2 • 6x OR LARGER BEAMS AND HEADERS DOUG-FIR #1 • POSTS AND TIMBERS DOUG-FIR #2 WOOD FRAMING SHALL BE KILN -DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY, OR EXPOSED TO EARTH OR WEATHER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA STANDARD U1 AND M4 FOR THE SPECIES, PRODUCT, PRESERVATIVE, AND END USE REQUIRED. STRUCTURAL WOOD PANEL SHEATHING USED ON WALLS, FLOORS, OR ROOFS SHALL CONFORM TO THEIR SPECIFIC REQUIREMENTS IN DOC PS 1, DOC PS 2, OR ANSI/APA PRP 210. PLYWOOD SHALL BE GRADE C-D WITH EXTERIOR GLUE. REFER TO IBC SECTIONS 2303.1.4, 2304.6, AND 2304.7 FOR ADDITIONAL COMPLIANCE REQUIREMENTS. NAILS, SCREWS, BOLTS, AND CONNECTORS REFER TO THE PLANS, NOTES, SCHEDULES, AND DETAILS FOR ALL NAILING REQUIREMENTS. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1. ALL NAILS SHALL CONFORM TO THE STANDARD DIMENSIONS OF COMMON NAILS AS DEFINED BY THE NDS AND SHALL MEET THE FOLLOWING MINIMUM GUIDELINES: • 8d = 0.131 "O x 2 1/2" • 10d = 0.148"0 X 3" • 16d = 0.162"0 x 3 1/2" 10d BOX NAILS (0.128"0 x 3) MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"0 x 3 1/4'), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THE DRAWINGS. OTHER NAILS MAY BE SUBSTITUTED ONLY WITH THE ENGINEER'S APPROVAL PRIOR TO START OF CONSTRUCTION. ALL LAG SCREWS AND BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE STANDARD CUT WASHERS UNDER THE HEADS AND NUTS OF ALL LAG SCREWS AND BOLTS BEARING ON WOOD. LEAD HOLES FOR BOLTS SHALL BE PROVIDED AND SHALL BE A MINIMUM OF 1/32" AND A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. LEAD HOLES FOR LAG SCREW SHANK AND THREADS SHALL BE PER NDS 12.1.4.2. ALL WOOD CONNECTORS SHALL BE SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUIVALENT. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS USING THEIR SPECIFIED NUMBER AND SIZE OF FASTENERS. IF STRAPS CONNECT TWO MEMBERS, PLACE 1/2 OF THE NAILS, SCREWS, OR BOLTS INTO EACH MEMBER. ALL NAILS, SCREWS, BOLTS, AND METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL City Of Edmonds SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITYAS DETERMINED BYASTM D155 . Building Department CONCRETE ALL CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH ACI 301 "STANDARD Work DECK SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318, "BUILDING CODE REQUIREMENTS FO STRUCTURAL CONCRETE". THE CONCRETE SHALL HAVE A UNIT WEIGHT OF APPROXIMATELY 150 P F CONCRETE STRENGTHS AT 28 DAYS (Yc) AND MIX CRITERIA SHALL BEAS FOLLOWS: Address 17706 69TH PL W • SLAB -ON -GRADE: f'c = 2,500 PSI 0.55 WIC RATIO Owner SPENCER • FOUNDATION & WALLS: f'c = 2,500 PSI 0.55 WIC RATIO - ----------------------- A CONCRETE MIX DESIGN SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL IF REQUIRED IN 1-* p�, ---------------------------- Date : 09/08/2023 0 SUBMITTAL SPECIFICATIONS. THE MIX DESIGN SHALL INCLUDE THE AMOUNTS OF CEMENT, FINEA I ----- COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, BuildingOfficial CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI REQUIREME 74; ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BEAIR-ENTRAIN -------------- Permit Number BLD2023-1072 ACCORDANCE WITH ACI TABLE 4.2.1 FOR MODERATE EXPOSURE CONDITION. MINIMUM CONCRETE COVER ON REINFORCING STEEL SHALL BE AS FOLLOWS: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. 3" • CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" • CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS, AND JOISTS 3/4" BEAM/COLUMN TIES AND STIRRUPS 1 1/2" REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615 GRADE 60. REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. WELDED WIRE REINFORCING SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS WITH 12" LAPS AT SIDES AND ENDS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS APPROVED BY THE ENGINEER. REFER TO ACI FOR PLACING TOLERANCES AND OTHER REINFORCING STEEL REQUIREMENTS. CONCRETE GENERAL NOTES WALL AND COLUMN VERTICAL BARS SHALL START FROM THE TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND/OR TOP OF FRAMED SLABS. THERE SHALL BE AN ADDITIONAL HORIZONTAL BAR AT A MAXIMUM OF 3" FROM EVERY TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH AND LAP ALL HORIZONTAL REINFORCING ON EACH SIDE OF THE CORNER PER SCHEDULE OR BEND ONE SIDE OF HORIZONTAL AROUND CORNER TO PROVIDE LAP SPLICE PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP EACH SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET. AREAS SHALL BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO PLACEMENT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT UNLESS NOTED OTHERWISE IN PLAN. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, STRIPS, TEXTURE, AND OTHER FINISH DETAILS AT EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS Aaln - ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED Ilk ,it )u e � �a HANDRAIL NOTES: 1. 36" MINIMUM HANDRAIL HEIGHT IS REQUIRED FOR ALL ELEVATED DECK SURFACES GREATER THAN 30" ABOVE GRADE. THERE SHALL BE NO MORE THAN A 4" OPENING BETWEEN RAILS OR ORNAMENTAL CLOSURES. IRC PRESCRIPTIVE HANDRAIL DETAILS HAVE BEEN PROVIDED FOR REFERENCE. HOMEOWNER HAS OPTION TO CONSTRUCT OR INSTALL A PRE -MANUFACTURED SYSTEM. PROVIDE IRC COMPLIANCE DOCUMENTATION TO THE JURISDICTION FOR APPROVAL PRIOR TO INSTALLATION. 2. REFER TO STAIR NOTES FOR ADDITIONAL HAND GRIP REQUIREMENTS AT STAIR LOCATIONS. 1. MAXIMUM RISE SHALL BE 7 3/4". MINIMUM RUN SHALL BE 10". 2. MINIMUM HEADROOM SHALL BE 6'-8". 3. MINIMUM STAIR WIDTH IS X-0". 4. HANDRAIL SHALL HAVE ENDS RETURNED TO WALL OR NEWEL POST AND SHALL BE PLACED BETWEEN 34" TO 38" (MINIMUM/MAXIMUM) ABOVE THE TREAD NOSING. 5. HAND GRIP SHALL NOT BE LESS THAN 1 1/2" NOR MORE THAN 2" IN CROSS SECTIONAL DIMENSION. REFER TO IRC FOR ADDITIONAL DIMENSIONAL TOLERANCES. 6. REFER TO TYPICAL STAIR FRAMING DETAIL FOR ADDITIONAL INFORMATION. LSrtr��S P�•2 DErM��� DECK FRAMING PLAN WOOD FRAMING GENERAL NOTES SILL PLATES BEARING ON CONCRETE FOUNDATIONS SHALL BE PRESSURE TREATED AND SHALL ATTACH TO THE CONCRETE WITH 1/2"0 ANCHOR BOLTS EMBEDDED 7" MINIMUM. PLACE ANCHORS AT 4'-0" OC MAXIMUM FOR SHEAR WALLS AND AT 6'-0" OC FOR BEARING AND PARTITION WALLS. USE A MINIMUM OF (2) ANCHOR BOLTS PER SILL PLATE AND PLACE ONE WITHIN 12" OF EACH END OF EACH PIECE. REFER TO THE SHEAR WALL SCHEDULE FOR MORE STRINGENT ANCHORAGE SIZE AND SPACING REQUIREMENTS. CONTRACTOR SHALL INSTALL 3 GAUGE PLATE WASHERS BENEATH EACH NUT AT EACH ANCHOR BOLT IN A SHEAR WALL THAT EXTEND TO WITHIN 1/2" OF SHEATHED EDGE. ALL SHEAR AND/OR BEARING WALLS SHALL BE FRAMED WITH 2x STUDS 0 16" OC. REFER TO PLAN NOTES FOR TYPICAL HEADER SIZES NOT SPECIFICALLY CALLED OUT. ALL HEADERS SHALL BE SUPPORTED BYA MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD. COLUMNS BELOW FLUSH FRAMED MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT SHALL BE (2) STUDS. BEAMS SHALL HAVE FULL BEARING ON COLUMNS AND POSITIVE CONNECTION SHALL BE PROVIDED. PROVIDE SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS, AT 8'-0" OC MAXIMUM SPACING BETWEEN SUPPORTS, AND BENEATH PARTITIONS PERPENDICULAR TO THE DIRECTION OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. MINIMUM NAILING REQUIREMENTS SHALL BE PER IBC TABLE 2304.10.1. THE USE OF NAIL GUNS IS APPROVED IF NAILING INTO THE DIAPHRAGMS IS FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. NOTCHES AND HOLES IN WALL STUDS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.5.9 AND 2308.5.10. NOTCHES AND HOLES IN JOISTS AND RAFTERS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.4.2 AND 2308.7.4. VERTICAL SHRINKAGE WILL OCCUR AND ACCUMULATE AT EACH LEVEL FROM THE WOOD DRYING OVER TIME. THIS IS ESTIMATED TO BE APPROXIMATELY 0.15" PER FLOOR AND ASSUMES THE WOOD HAS AN INITIAL MOISTURE CONTENT OF 19% OR LESS. ADDITIONAL SHRINKAGE WILL OCCUR IF THE MOISTURE CONTENT IS HIGHER. THE CONTRACTOR SHALL ALLOW FOR THIS MOVEMENT IN THEIR INSTALLATION OF ALL VERTICAL ASSEMBLIES INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, MECHANICAL, AND ARCHITECTURAL SYSTEMS. /, ,- / -,-- M�USC- No TGxj �NF"I- GENERAL NOTES STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THEARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR ELEVATIONS, SLOPES, NON -BEARING WALLS, STAIRS, CURBS, DRAINS, RAILINGS, WATERPROOFING, FINISHES, ETC. REFER TO THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPES, VENTS, DUCTS, AND OTHER OPENINGS NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS FOR COMPATIBILITY WITH THE PLANS, SPECIFICATIONS, AND REFERENCED STANDARDS BEFORE PROCEEDING WITH ANY WORK. THE MOST STRINGENT REQUIREMENT SHALL GOVERN ANY CONFLICT UNLESS APPROVED IN WRITING OTHERWISE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM BEFORE PROCEEDING. CONTRACTOR SHALL BE RESPONSIBLE FOR STRENGTH AND STABILITY OF ANY PARTLY COMPLETED STRUCTURE. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY AND SHALL PROVIDE TEMPORARY SHORING AND SUPPORT AS REQUIRED UNTIL THE STRUCTURE HAS BEEN COMPLETED. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE DESIGN TEAM FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES ON SHOP DRAWINGS DO NOT SATISFY THIS REQUIREMENT. REVIEW OF ALTERNATE SYSTEMS MAY BEAN ADDITIONAL SERVICE BY THE ENGINEER. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE DESIGN TEAM. 1. HOMEOWNER HAS OPTION FOR A DECK SURFACE OF COMPOSITE MATERIAL OR 2x CEDAR DECKING. INSTALL COMPOSITE DECKING IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. INSTALL 2x CEDAR DECKING WITH (2) #8 SCREWS OR (2) 8d NAILS INTO EACH JOIST. BOTH DECKING SYSTEMS SHALL BE INSTALLED WITH A 1/8" GAP BETWEEN BOARDS. 2. GALVANIZED 'Z" FLASHING WITH A MINIMUM THICKNESS OF 0.019" SHALL BE PROVIDED OVER ALL LEDGER LOCATIONS WITH THE UPPER LEG INSTALLED BEHIND THE EXISTING SIDING AND THE DRIP EDGE ON THE OUTSIDE FACE OF THE LEDGER. CAULK JOINTS TO PREVENT WATER INTRUSION. 3. PROVIDE SOLID 2x BLOCKING BETWEEN EACH JOIST WHERE RUN CONTINOUS OVER THE TOP OF BEAMS. END & TOE NAIL CONVENTIONALLY PER IRC REQUIREMENTS. PT 9-%-x 10 hF C vr,c,P�_ w/ 4 (Ir U60 (YA Lo 19 � 110 C i fi`1P �Mo aX�oKF�a 2>) D8� DIST o2 R! V\ po�- Z 4- 1- 4 W W Z o W �i c a� A RECEIVED Aug 29 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LU V 0 � U � z LQ � o w W v , U LLj O CL O A. pF WASk 400785 SIDIVAL 0d/ I4/ 23 REV. DATE DESCRIPTION 0 08114123 PERMIT SUBMITTAL PROJECT NO.: 23084.01 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE. NOTES & FRAMING PLAN SHEET NO.: PLANS MUST BE ON JOB SITE SCALE: NTS POST PER PLAN (4) #3 TIES @a 1 1/2" OC W/ BALANCE Ca 9" OC. LAP MPBZ POST BASE TIES OR PROVIDE 180° PER PLAN W/ 1 " HOOK AROUND VERT MIN STANDOFF —y ° ° 3"CLR FINISHED GRADE °p° o o e e 7N Q U a I 1'-8" x 1'-8" PIER W/ (8) #4 VERT 1'-8" FOUNDATION DETAIL LENGTH OF NOTCH SHALL NOT EXCEED 1/3RD THE O JOIST DEPTH U) O T PRE -DRILL HOLE AT CORNERS OF NOTCHES. DO NOT OVERCUT—,M----,--,, NOTCH AT END OF JOISTS SHALL NOT EXCEED 1/4 THE JOIST DEPTH. DO NOT NOTCH WHERE PRACTICABLE. x Z W Q "' OR HOLE 0 1/4 OF STUD WIDTH MAX z_ MAX HOLE O SHALL NOT N T EXCEED 40 % THE STUD DEPTH (I.E. 2 1/4" FOR 2x6, c: 1 1/4" FOR 2x4). MINIMIZE ol 5/8" MIN CLR HOLE DIAMETER WHERE TO EDGE POSSIBLE. MAX HOLE O SHALL NOT EXCEED 1/3 THE JOIST DEPTH (I.E. 3" FOR 2x10, 3.75" FOR 2x 12). MINIMIZE HOLE DIAMETER WHERE POSSIBLE. Q� J m U �s �O N 2x JOISTS PER PLAN OR SCHEDULE. REFER TO MFR RECOMMENDATIONS FOR I -JOIST HOLES AND NOTCHES. NOTE: 1. NOTCHES ARE NOT PERMITTED IN THE MIDDLE 1/3 OF THE JOIST SPAN. 2. NOTCHES ARE NOT PERMITTED ON THE BOTTOM (TENSION FACE) OF JOISTS WHERE THE WIDTH IS 4x OR GREATER. ALLOWABLE HOLES & NOTCHES SCALE: 1 " = 1 '-0" \ / SCALE: 1 " = 1 '-O" (2) 1/2"0 w/ WASHL1. 1 . , . TYPICAL GUARD ELEVATION SCALE: 1 " = 1 '-O" 2x6 TOP RAIL. ATTACH TO EA POST w/ (3) #12 x 3" SCREWS OR (3) 16d RING SHANK NAILS 2x4 TOP & BOT. ATTACH TO POST w/ (2) 8d RING SHANK NAILS OR (2) #8 x 2 1/2" OR LONGER SCREWS NOTE: REFER TO TYPICAL GUARD SECTIONS FOR INFORMATION NOT CALLED OUT. 2x2 BALUSTER TYP 4x4 POST, TYP. DO NOT NOTCH CEDAR DECKING UNO BY OWNER RIM JOIST PER FRAMING PLAN 2x12 NOTCHED STRINGER TREADS PER ARCH. FRAMING PER PLAN W/2x6 REINFORCEMENT USE 1 1/8" PLYWOOD & 8' MAX SPAN TREAD UNO. 2x 12 NOTCHED STRINGER w/2x6 REINFORCEMENT 71 2x BLKG Ca EA STRINGER AT LANDINGS. ADD (3) 1Od 16" OC MAX • NAILS EA SIDE UNO ON PLANS SIMPSON LSSU210-2 EA STRINGER STRINGER W/ (3) 1Od TYP EA SIDE OF MID -SPAN BEAM EA STUD AT WALLS. WHERE APPLICABLE STRINGER 9 BEAM OR LANDING STRINGER SECTION TREAD & RISER PER ARCH. USE 1 1/8" PLYWOOD TREAD UNO. 2x BLKG TIGHT TO STRINGERS PT 2x THRUST PLATE TIGHT TO STRINGERS. PROVIDE (2) HILT/ • X-DNI FASTENERS EA BLOCK w/ 2" MIN EMBED INTO FTG. ° o o Off° a NO o • Cz Q C J c U STRINGER 0 LOWER LANDING TYPICAL STAIR DETAILS SCALE: 1 " = 1 '-O" NOTE. 1. POSTS MAYBE INSTALLED ON EITHER SIDE OF RIM. 2. REFER TO TYPICAL GUARD ELEVATION FOR ADDITIONAL INFORMATION NOT SPECIFICALLY CALLED OUT. 3. REFER TO BOTH PARALLEL & PERPENDICULAR CONDITIONS FOR INFORMATION. Z N (off 4x4 GUARD POST PER TYPICAL GUARD ELEVATION. DO NOT NOTCH. RIM JOIST PER FRAMING PLAN DECK FRAMING PER PLAN ? 1800 LB TENSION Q STRAP EA SIDE OF cv BLKG Lo N cV 2x BLKG 0 EA POST. ADD (3) 10d RING SHANK NAILS EA SIDE POST 0 RIM PARALLEL TO JOIST TYPICAL GUARD SECTIONS SCALE: 1 " = 1 '-O" 2x 12 NOTCHED STRINGER @a 16" OC MAX SPACING W/ 8' MAX SPAN. DO NOT OVERCUT TREAD OR RISER NOTCHES 2x6 SISTERED TO SIDE OF 2x 12 W/ (2) ROWS OF 1Od NAILS STAGGERED Ca 6" OC AS SHOWN FTG PER PLAN NOTE: 1. REFER TO ARCH DWGS & IBC FOR DIMENSIONAL TOLERANCES OF STAIRS & LANDINGS. 2. PROVIDE GUARD AND HANDRAILS AS REQUIRED PER IBC. 3. MAXIMUM STRINGER SPAN IS 8'-0". PROVIDE INTERMEDIATE SUPPORT WHERE SPANS EXCEED THIS. EDGE BEAM PER PT 2x LEDGER TO MATCH DECK FRAMING PLAN JOIST DEPTH. PROVIDE 4" LEDGERLOK 0a 4" OC STAGGERED TOP & BOT DECK FRAMING PER PLAN 1800 LB TENSION PT 2x DECK JOISTS l� STRAP 0 JOIST. IF POST BTWN JOISTS, STEM OR BASEMENT PROVIDE (1) STRAP Ca WALL PER PLAN EA ADJACENT JOIST POST 0 RIM PERPENDICULAR TO JOIST LEDGER DETAIL SCALE: 1 " = 1 '-O" � Z o 0 p--p � o W W p"p Z W o �i c °• I.. j a� A 3 3 3 RECEIVED Aug 29 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V LQ 0 U LU J Q Cc z kz � 0 V � Uj LIJ U Lli O cc CL A. WA O ` ORAL 5' S`SIONAL 08/ I4/ 2� REV. DATE 08114123 DESCRIPTION 0 PERMIT SUBMITTAL _E7 — PROJECT NO.: 23084.01 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE: MAIN FLOOR FRAMING PLAN SHEET NO.: S2.1