Loading...
APPROVED BLD RESUB1 BLD2024-1035+Architectural_Plan+8.29.2024_12.06.52_PM+44708043' stairs landing HARDWARE & FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF MANUFACTURER'S RECOMMENDATIONS A MINIMUM OF ASTM A 653 TYPE 1 G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. IRC R317.3.1 IBC 2304.10.5.1 4' MW I........................- ..............................i Existinq house 1 ij F - II II F_111 li F-1 11fft 3" L T-1" 5'-4" t1L 5,-1" 16' 17 Revised and corrected footing size Garden DECK FRAMING AND FOUNDATION PLAN Scale %4 in = 1 ft FOOTING SPECIFICATIONS Total depth = 18 in F-1 ® Base diameter = 24 in Pier diameter = 9 in Footings to be installed to 18" as required by local building ordinance. Frost footing sizes based on 55lbs per square foot tributary loads applied to 1500 psi soil compression capacity (assumed clay soil). 3' stairs landing 2x10 Ledger Board LedgerLOK Structural Ledger Board Screws - 5 inch wood screws with hex head Beam 12' span- Pressure Treated Hem Fir 6x10 Premium Grade Incised Ground Contact Cedar Toned S4S Pressure Treated joists 11'6" span- 2x10 • Premium Grade Hem/Fir - Incised Ground Contact • Cedar Toned S4S • 16" O.C. Revised and ror tad jots[ span Pressure Treated post- Hem/Fir 6x6 Premium Grade Incised Ground Contact Cedar Toned S4S Simpson strong tie LU210 20 ag uge 2 x 10 Joist hangers 3' stairs landing ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE MW DECK FLOORPLAN Scale %4 in = 1 ft APPROVED PLANS MUST BE ON JOB SITE RES U B Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Garden City Of Edmonds Building Department Work ' DECK ---------------------------------------------- --------------------------------------------- Address 21828 76TH PL W ------------------ Owner KENNEDY ---------------------- ------- -------------------- ------- Approved Date 09/03/2024 Building Official ;--------------__ ------------------------- Permit Number BLD2024-1035 5 n v \ CTempered 3M Safety S140 Sliding lm ANSI Z97.1-2015 CPSC 1601 I Revised and m—aa - ly glazing 2x10 Ledger Board Ledgerl-OK Structural Ledger Board Screws - 5 inch wood screws with hex head Beam 12' span- Pressure Treated Hem/Fir 6x10 Premium Grade Inc Ground Contact Cedar Toned S4E Tempered 3M Safety S140 Window Film ANSI Z97.1-2015 CPSC 16 CFR 1201 I Revised and corrected safely glazing 1 1 GUARDS SHALL NOT HAVE AN OPENING FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE IN ACCORDANCE WITH 2O21 IRC R312.1.3. 1 1 I: CROSS SECTION 1 Scale %4 in = 1 ft Fortress Steel Deck Railing Systen 42" high SOUTH ELEVATION Scale %4 in = 1 ft RESUB Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing 2x band joist Interior floor ioist Existing Stud Wall Threshold carefully flashed and caulked to prevent water intrusion Continuous flashing extending past joist Ledgerl-OK Structural Ledger Board Screws - 5 inch wood screws with hex head 2x10 Ledger Board Simpson strong tie LU210 20 gauge 2 x 10 Joist hangers V DECK LEDGER DETAIL N.T.S 3' stairs landing 3' STAIR DETAIL 2 N.T.S • 7 1/2" , 11" , 11" 2" LEDGER BOARD SPACING AND FASTENING PATTERN DETAIL N.T.S LedgerLOK Structural Ledger Board Screws - 5 inch wood screws with hex head 2x10 Ledger Board 16' span Approved post cap Beam 12' span- Pressure Treated Hem/Fir 6x10 Premium Grade Incised Ground Contact Cedar Toned S4S Pressure Treated post- Hem/Fir 6x6 Premium Grade Incised Ground Contact Cedar Toned S4S Concrete footing P. ...• •.. •: �. :R BEAM, POST AND FOOTING DETAIL N.T.S Added detail for fastener spacing and pattern RESUB Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT