Loading...
APPROVED BLD BLD2024-1061+Architectural_Plan+8.14.2024_11.59.39_AM+4440349A. THIS STRUCTURAL DRAWING SHALL ONLY BE USED FOR THE SITE LISTED ON THE DRAWING. B. THE STRUCTURE IS UNSTABLE UNTIL ALL LOAD BEARING WALLS ARE ERECTED AND CONNECTIONS ARE COMPLETELY BOLTED. THE DESIGN ADEQUACY OF TEMPORARY BRACING AND SHORING IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. C. PROMPTLY REPORT DEVIATIONS AND INTERFERENCES WITH STRUCTURAL COMPONENTS FOR RESOLUTION BY THE ENGINEER. D. THESE STRUCTURAL PLANS ARE BASED ON INFORMATION PROVIDED TO THIS OFFICE. THE ENGINEER SHALL BE ENTITLED TO RELY ON THE ACCURACY AND COMPLETENESS OF THIS INFORMATION IN THE PREPARATION OF THE CONSTRUCTION DOCUMENTS. E. WHERE LOCATIONS ARE NOT SPECIFICALLY DIMENSIONED, THE FOLLOWING RULES SHALL APPLY: F. FOOTINGS ARE CENTERED BENEATH COLUMNS. G. CONTINUOUS FOOTINGS ARE CENTERED BENEATH WALLS. H. REFER TO ARCHITECTURAL DRAWINGS FOR WALL EXTENTS AND OPENINGS 2. DESIGN AND CODE INFORMATION A. ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE i. 2021 INTERNATIONAL RESIDENTIALCODE ii. STRUCTURAL CONCRETE CODE -AMERICAN CONCRETE INSTITUTE (ACI) 318-19 iii. STRUCTURAL TIMBERS CODE - NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION ANSI/AWC NDS (LATEST EDITION) iv. ASCE MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-16) DESIGN LOADS A. DESIGN LIVE LOADS a. ROOF20 PSF b. FLOOR (AREAS OTHER THAN SLEEPING AREAS)40 PSF B. DESIGN DEAD LOADS a. ROOF12 PSF C. WIND LOADS a. WIND SPEED 98 MPH b. RISK CATEGORY II c. EXPOSURE D D. EARTHQUAKE LOADS a. RISK CATEGORY II b. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS c. SS 1.29 d. S1 0.454 e. TL6 f. SITE CLASS D GROUND SNOW LOAD25 PSF* *CLOSEST TO SNOHOMISH COUNTY, PER CASE STUDY WACO-SEAW WHITE PAPER SNOW LOAD REGULATIONS AND ENGINEERING PRACTICES WASHINGTON STATE, AUGUST 2000 3. FOUNDATIONS b)ASSUMED NET ALLOWABLE BEARING PRESSURE = 2000 PSF c) FOOTINGS SHALL BEAR EITHER ON COMPETENT NATIVE SOIL OR COMPACTED STRUCTURAL FILL. d) WOOD SILL PLATES IN CONTACT WITH REINFORCED CONCRETE, MASONRY, FOUNDATION ELEMENTS SHALL BE PRESSURE TREATED OR OTHERWISE PROTECTED FROM MOISTURE. ALL DECK TIMBER TO BE PRESSURE TREATED. f) EXTERIOR AND INTERIOR PERIMETER FOOTINGS SHALL BEAR NOT LESS THAN 24 INCHES BELOW FINISH GRADE. IF THE SOIL AT THE BEARING ELEVATIONS SHOWN IS OF QUESTIONABLE BEARING VALUE, THE STRUCTURAL ENGINEER OF RECORD OR ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. g) PROVIDE A MINIMUM OF 4-INCH CLEAN, FREE -DRAINING GRANULAR SUBBASE FILL BELOW ALL INTERIOR SLABS -ON -GRADE UNLESS NOTED OR DETAILED OTHERWISE. SUBBASE SHALL MEET GRADATION REQUIREMENTS OF ASTM C-33 SIZE NO. 67. GRADING 1. SOIL SHALL BE GRADED 6 INCHES WITHIN THE FIRST 10 FEETAWAY FROM THE FOUNDATION. 2. GRADING PLAN/INFORMATION WERE UNAVAILABLE DURING THE FOUNDATION DESIGN THEREFORE FOUNDATION ELEVATIONS SHOWN ON THE PLAN ASSUME A UNIFORM FINISH GRADE 6" BELOW FINISH FLOOR ELEVATION AROUND THE PERIMETER OF THE BUILDING. IF SITE CONDITIONS VARY FROM THAT STATED, CONTRACTOR SHALL NOTIFY ARCHITECT AND STRUCTURAL ENGINEER FOR A RE -DESIGN OF THE FOUNDATION SYSTEM TO ACCOMODATE ACTUAL SITE CONDITIONS. 3. ANY EXTERIOR SLABS SHALL SLOPE AWAY FROM BUILDING '/4" PER FOOT UNO. 4. CONCRETE 1. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 2,500 PSI. 2. CONCRETE SHALL BE 6% +/- 1.5% AIR ENTRAINED. 3. MAXIMUM WATER CONTENT SHALL BE 0.4. 4. MAXIMUM NOMINAL AGGREGATE SIZE SHALL BE 1 1/3 INCHES WITH 1 INCHES PREFERRED. 5. CONCRETE SHALL CONFIRM TO THE SPECIFICATION FOR STRUCTURAL CONCRETE, ACI 301. 6. CONCRETE REINFORCEMENT DETAILS SHALL CONFORM TO ACI 315, LINO. 7. MINIMUM STRENGTH OF CONCRETE REINFORCEMENT SHALL BE AS FOLLOWS UNO: 8. #3&#4 DEFORMED BARS FOR TIES AND STIRRUPS ONLY (ASTM, A615, GR 40) 9. #5 AND LARGER DEFORMED BARS (ASTM A615 GRADE 60). 10. LAP ALL REINFORCING BAR SPLICES 30 BAR DIAMETERS OR 24 ", WHICHEVER IS GREATER LINO. 11. REINFORCING IN PILES, FOOTINGS, GRADE BEAMS, AND FOUNDATION WALLS SHALL BE SUPPORTED FROM ABOVE WHILE PLACING CONCRETE. 12. EXTERIOR SLABS SHALL SLOPE AWAY FROM BUILDING'/4" PER FOOT UNO. 13. CONTRACTOR SHALL FOLLOW SPECIFICATION ACI 305 FOR HOT WEATHER CONCRETE AND ACI 306 FOR COLD WEATHER CONCRETING. 14. ARRANGEMENTS AND DETAIL OF REINFORCING BENDS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF PUBLICATION SP-66, "ACI DETAILING MANUAL," AND ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. FOUNDATION PLAN NOTES A. MULTIPLE MEMBER CONNECTIONS TO BE GLUED TOGETHER AND FASTENED TOGETHER USING (3) ROWS OF 3" LONG 10D NAILS AT 12" OC ON BOTH SIDES C. FRAMING SHALL BE PER NOTES IN CALCS. F. PROVIDE SOLID, FULL DEPTH BLOCKING AT MIDDLE OF ALL DECK JOISTS UNLESS NOTED OTHERWISE. CONNECTIONS A. NAILING OF WOOD FRAMING SHALL BE IN ACCORDANCE WITH "FASTENING SCHEDULE" TABLE R602.3(1) IN THE 2021 INTERNATIONAL RESIDENTIAL CODE UNLESS HIGHER FASTENING REQUIREMENTS ARE REQUIRED WITHIN THESE PLANS. B. METAL CONNECTORS REFERENCED ON DETAILS ARE "STRONG TIE" CONNECTORS MANUFACTURED BY SIMPSON CO. C. PROVIDE SOLID, FULL DEPTH BLOCKING AT MID -HEIGHT FOR STUD WALLS. D. JOIST HANGER LU28-2 OR BETTER AT BEAM CONNECTIONS E. UPLIFT CONNECTION REQUIREMENTS a. HURRICANE TIES, (1) H2.5AATTACH TO JOIST TO BEAM WITH (5) 8D X 2.5 COMMON NAILS AND TO THE BEAM WITH (5) 8D X 2.5 COMMON NAILS AT EACH HURRICANE TIE OR PER SIMPSON REQUIREMENTS. HOLD DOWN REQUIREMENTS. DECKING TO BE INSTALLED PER COMPOSITE MANUFACTURES SPECS, OR WITH STANDARD PRESSURE TREATED LUMBER Calculation j � SEISMIC ANALYSIS WIND ANALYSIS 1 WIND ANALYSIS 2 DJ1 1311 F1 R1 L1 SNOW LOAD ANALYS 38% j f-96%_) 72% j 59% j 59% j V j STRUCTURAL DESIGN BY PROFESSIONAL ENGINEER MOHAMED SAID MAHMOUD PE# 23001965 EXPIRATION 06-12-2025 Mohamed Digitally signed by Mohamed S S Mahmoud Mahmoud Date: 2024.08.08 21:07:23-07'00' ON s, a, '0 0/\1;, 2 �100 PA � :.o/1o.: ems, 4 � \� oF�T�2109 • � DESIGN 5 0 U Q U � f � SAID WS 23001965 GIs 1E NAL E��l Q Q w � Q � w O U �o U 7t M N Z H OaW� aQQo � rx��N QQQ.� DATE: 08/08/24 SCALE: 1 /4"=1' SHEET: S1 Q 1 T"Ill V/ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6'-5" 6'-11" 8'-1 1/16" 5'-2" 6-4" 4'-7 5/16" 6'-4" 21'-5 1 / 16" —7n 6-7 7/8" L'�V OR ANCHOR WASHER CLEARANCE FROM FASTENER TO BOTTOM OF LEDGER, MINIMUM 7.5" FOR 2X12 LEDGER BOARD FASTENING SPACING AND CLEARANCE DETAIL SEE SIMPSON DETAILS D22 FOR DTT1Z CONNECTION Scale: N.T.S. 52' 23'-11 1/16' " I AUGER FASTENERS IN TWO ROWS MINIMUM 2" FROM EDGE OF LEDGER 0 F-5 3/4" FOUNDATION PLAN PIER SCHEDULE MARK SIZE (WXD) F 1 18" DIAMETER ROUND X 3FT DEPTH MINIMUM PAST FROST DEPTH LWO 1'/2" minimum from top of ledger and band joist F. 4" to 5" L On -center spacing from end of of SDS wood screws ledger per designer SDS Ledger Installation 1'/z' minimum from bottom of ledger and band joist Thread Length(in.) Size (in.) Model No. '/4' x 3'/2" SDS25312 2'/4 '/4" x 5" SDS25500 21/4 1.D indicates connector is available in stainless steel. Add SS to model number when ordering. 2. Refer to current F-SDSLDGR for spacing and additional information. 3. The screws shall be staggered from the top to the bottom along the horizontal run of the deck ledger per IRC 2018 Section R502.2.2.1.1. Scale: N.T.S. 3" minimum row spacing co) SIDS Screw Installation: • Install Simpson Strong -Tie SDS wood screws with a %" hex head driver. • SDS screws install best with a low speed %" drill. STRUCTURAL DESIGN BY PROFESSIONAL ENGINEER MOHAMED SAID MAHMOUD PE# 23001965 EXPIRATION 06-12-2025 FRAMING SCHEDULE MARK SIZE B1 (3) 2X12 DFL NO 2 10'-6" MAX LENGTH DJ1 2X10 DFL NO 2 DECK JOIST 16" ON CENTER C1 6X6 DFL NO 2 DECK POST R1 2X10 DFL NO 2 RIM BOARD L1 2X10 DFL NO 2 LEDGER BOARD -3INCH BEARING WIDTH, TYP. FOR ALL BEAMS -SEE DETAILS AND NOTES FOR CONNECTORS -ALL LUMBER TO BE PRESSURE TREATED IE 10' E 10' E 10' E (j'� SAID WAS 19 � d 23001965 �`� V1 wOQ�j 0 � W U� U Q�'Zo aQQo >n 0 cv QQQ.� -DATE: 08/08/24 SCALE: 1 /4"=1' SHEET: S2 0 U N Q U rx a� Q a� z TOP OF SUBFLC 10'-: TOP OF SUBFL( STRUCTURAL DESIGN BY PROFESSIONAL ENGINEER MOHAMED SAID MAHMOUD PE# 23001965 EXPIRATION 06-12-2025 36" HANDRAIIL ),PPROX GRADE SAID d� 235 1965 GISTER�� AL 0 Q H� 0. > -1 Q a� z W 0 Q Q�z 0 � Q OW U� Q�'Zo aQQo 0 cv QQQ.� DATE: 08/08/24 Y F 3, • SCALE: 1/4 -1 JP 0oo11N ,G' 0000oQ SHEET. ��r2109 (4151S 3 • DESIGN 2X BLOCKING W/`�\—Tyr KIAnc rA BLOC STRUCTURAL DESIGN BY PROFESSIONAL ENGINEER MOHAMED SAID MAHMOUD PE# 23001965 EXPIRATION 06-12-2025 P.T. POST PER PLAN JOISTS PER PLAN POST BASE FTG PER PLAN14 CBSQ44 FOR 4X4 POST W/ 1/12 TOP SLOPE CBSQ66 FOR 6X6 POST H1 TIE @ E.A. JST BEAM PER PLAN GRADE LEVEL SIMPS. AC POST CAP EA. SIDE Ij ? POST PER PLAN ' Z OD SIMPS. A24 ANGLE 9 a OR; EQUIVALENT WITH POSITIVE 4 -A ACHRORAGE TO FTG.- FOOTING PIER PER PLAN a a CRAWL SAPCELEVEL OPTIONAL CBQ66 OR ANCHOR - �° 9 . 'd ".• p..a a BOLT FOR UPLIFT TO PIER =' BEAM PER PLAN 4 "' °, • -1� 8" MIN. BELOW FROST LEVEL 'TURBED, FIRM NATURAL SOIL )IMPACTED SOIL PER SOIL - - - - RT SIZE PER PLAN JOIST TO BEAM CONNECTION DECK POST DETAILS 3/4" = 1'-01 1 ♦I Y 0 F Q-`' O`oo�N si or ,00/11;N 2 wommumu. A. ��r2109 (4151���P • DESIGN f � SAID S 23001965 GISTER�� AL E��l 4-1 w C) Q�z oW Q�'Zo aQQo O DATE: 08/08/24 SCALE: 1 /411=1' SHEET: S4 0 Q H� s~ � a� Q a� z Z Scale: N.T.S. �H2.5Z o UDa 0 0 ° ® 3 1°f1e' ® m ° o , Typical H 1 Z and H2.5Z Installation 81dy Installation: • Use all specified fasteners. H 1 Z Fasteners Model No. Nails SD Screws To Joist To Beam To Joist To Beam H1Z 6-8dx1'/z 4-8dx1'/2 6-SD #9x1'/2 4-SD #9x1'/2 H2.5Z 5-8dxl'/2 5-8dx1'/2 5-SD #9x1'/2 5-SD #9x1'/2 HE 5-10dx1'/2 5-10dx1'/2 5-SD #9x1'/2 5-SD #9x1'/2 1. indicates connector is available in stainless steel. Replace Z in model number with SS when ordering. 2. Refer to current Wood Construction Connectors catalog for additional information. HURRICANE TIES Installation: "mew • Install Simpson Strong -Tie m m SDS wood screws with a %" hex m head driver. SDS screws install best with a low speed high torque m m drill. • A standard cut washer \ (provided) must be installed between the nut and the DTT2Z seat. • Bolt holes shall be a minimum %z' to a maximum %6' larger than the bolt diameter. DTT2Z DTT2Z 13i16 1/2" 8-SDS VOW' H8Z Post \ Decking DM 0 2• o ° o 0 0 0.T W diameter Rim machine bolds or threaded rods with joist Joist nuts and washers DTT2Z Installed as a Lateral Connector for a Deck Guardrail Post. 1.E> indicates connector is available in stainless steel. Replace Z in model number with SS when ordering. 2. Refer to T-GRDRLPST and T-DECKLATLOAD for additional information. DTT2Z DECK TENSION TIE w °® H Wz 1 D Typical CBSQ 3" Side Installation: • Install Simpson Strong -Tie SDS %" x 2" wood screws, which are provided with the column base, with a %" hex head driver. (Lag screws will not achieve the same load.) • Allow concrete to cure before installation of the post. • For full loads, a minimum of 3" side cover shall be provided. ypical CBSQ44 Installation Model No. Post Size Dimensions (in.) Number of SDS Screws W1 W2 D H CBSQ44-SDS2HDG 44 3 9/16 31/2 7 1/8 8 3/8 14-SDS'/4'x2" CBSQ46-SDS2HDG 46 3 9/16 5 5/16 713/16 811/16 14-SDS Vx2" CBSQ66-SDS2HDG 64 5 1/2 51/2 6 7/8 8 3/4 14-SDS Vx2" CBSQ86-SDS2HDG 6x8 7 1/2 5 3/8 6 1/8 811/16 12-SDS Vx2" CBSQ88-SDS2HDG 8x8 7 1/2 7 3/8 6 1/8 811/16 12-SDS'/4'x2" 10 CBS POST BASES 0 0 I IVI LAO 1/16 IVI 3x's and 4x's :WB LUS Typical LUS28Z Installation Installation: • LUS hangers install with double shear nailing. • For installations into single 2x headers or ledgers, use the specified full length fasteners into the joist and the following fasteners into the header for reduced loads in accordance with www.strongtie.com: •• 10dx1'/2 nails for installations with Nails •• SD #9x1'/2 for LUS28Z and LUS210Z installations with SD Screws •• SD #10x1'/2 for LUS26-2Z and LUS210-2Z installations with SD Screws Model No. Dimensions (in.) Fasteners Nails SD Screws LUS26Z W 1 9/16 H B Header Joist Header - Joist 4 3/4 1 3/4 4-10d 4-10d - LUS28Z 1 9/16 6 5/8 1 3/4 6-10d 4-10d 6-SD #9x2l/2 4-SD #9x2'/2 LUS210Z 1 9/16 7 13/16 1 3/4 8-10d 4-10d 8-SD #9x2'/2 4-SD #9x2'/2 LUS26-2Z 3 1/8 4 7/8 2 4-16d 4-16d 4-SD #10x2'/2 4-SD #10x2%2 LUS210-2Z 31/8 9 2 8-16d 6-16d 8-SD #10x21/2 6-SD #10x2'/2 n LUS JOIST HANGERS E> E> L> 1. E> indicates connector is available in stainless steel. Replace HDG in model number with SS when ordering. 2. Refer to current Wood Construction Connectors catalog for additional information. 1%' minimum from top of ledger and band joist 0 L On -center spacing from end of of SDS wood screws 1'/"minimum from ledger per designer bottom of ledger and band joist SIDS Ledger Installation Thread Length(in.) Size (in.) Model No. V x 3'W SDS25312 2'/4 '/" x 5" SDS25500 2% 1. indicates connector is available in stainless steel. Add SS to model number when ordering. 2. Refer to current F-SDSLDGR for spacing and additional information. 3. The screws shall be staggered from the top to the bottom along the horizontal run of the deck ledger per IRC 2018 Section R502.2.2.1.1. 3" minimum row spacing M 10 SDS Screw STRUCTURAL DESIGN BY PROFESSIONAL ENGINEER MOHAMED SAID MAHMOUD PE# 23001965 EXPIRATION 06-12-2025 Installation: • Use all specified fasteners. • Strong -Drive SD Connector screws install with a'/a" hex head driver (Model DBHEX) • Strong -Drive SDWH Timber -Hex HDG screws install with a a" hex head driver (Model DB6H1.75) Model CL Anchor Dia. Fasteners No. DTT1Z %" %" or SDWH 6-SD#9x1%" Installation: • Install Simpson D n LL^ Strong -Tie SDS wood screws with a %" hex head driver. • SDS screws install best with a low speed %" drill. SDS LEDGER INSTALLATION m m CC ® ECC m ® m Typical CC ® Installation Installation: Beam depth must be at least as tall as H1. • For end conditions, specify ECC Bolt holes shall be a minimum Y2" to a maximum Ys" larger than the bolt diameter. • Contact engineered wood manufacturers for connections that are not through the wide face. Model No. Beam Width Dimensions (in.) Machine Bolts W1 WZ L H1 Dia. Beam Post CC ECC CC ECC CC3-1/4-4HDG 31/8 31/4 3 5/8 11 71/2 61/2 5/8 4 2 2 CC3-1/4-6HDG 31/8 31/4 51/2 11 71/2 6112 5/8 4 2 2 CC44HDG 4x 3518 35/8 7 51/2 4 5/8 2 1 2 CC66HDG 6x 51/2 1 51/2 1 11 71/2 6112 5/8 4 2 2 CC, ECC POST CAPS DTT1Z Deck Tension Tie Scale: N.T.S. Floor sheathing V diameter naiked at S' max. HDG threaded on center to Doist rod with nuts with holdown and washers o- Continuous flashing (per code), not shown �1\111��mnmmmm-`�IIII ��Illlllmmmmmunmm�m� ■111111� Floor joist Deck DTT2 (Solid 2xiolist or joist � 2) blocklidng) Cr00 ,%0/\1W, 2 0/\ A ems, 4 � � \ oF�T 21no t47515e���P�, • DESIGN 5 0 U rn N Q a� GG (� b o •� pC Q a. z f � �S WI S 23001965 GISTER�� AL E��l v � Q Q Q O WU� U U aa��N I�QQp zN CnC� 0 QQQ DATE: 08/08/24 SCALE: 1 /411=1' SHEET: SS